1
|
Narita R, Sakurai Y. Estimation of internal-exposure contribution in radiation dose exposure for boron neutron capture therapy. RADIATION PROTECTION DOSIMETRY 2024; 200:623-628. [PMID: 38527175 DOI: 10.1093/rpd/ncae073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 02/12/2024] [Accepted: 03/03/2024] [Indexed: 03/27/2024]
Abstract
Although boron neutron capture therapy (BNCT) causes minor damage to normal cells owing to the nuclear reactions induced by neutrons with major elements of tissues such as hydrogen and nitrogen, it is useful to estimate the accurate exposure dose for radiation protection. This study aims to estimate the contribution of internal exposure in radiation exposure dose for BNCT. The study was performed by referring to clinical studies at a reactor-based BNCT facility on the basis of computational dosimetry. Five irradiation regions of head and neck were selected for the estimation. The results suggest that external exposure occurred primarily in and around the irradiation field. Furthermore, during the exposure dose estimation in BNCT, internal exposure was found to be not negligible, implying that the irradiation regions in treatment planning must be considered for avoiding damage to certain critical organs that are susceptible to internal exposure.
Collapse
Affiliation(s)
- Ryosuke Narita
- Graduate School of Engineering, Kyoto University, Kyoto daigaku-katsura, Nishikyo-ku, Kyoto 615-8530, Japan
| | - Yoshinori Sakurai
- Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2, Asashiro-Nishi, Kumatori-cho, Sennan-gun, Osaka 590-0494, Japan
| |
Collapse
|
2
|
Yu LS, Jhunjhunwala M, Hong SY, Yu LY, Lin WR, Chen CS. Tissue Architecture Influences the Biological Effectiveness of Boron Neutron Capture Therapy in In Vitro/In Silico Three-Dimensional Self-Assembly Cell Models of Pancreatic Cancers. Cancers (Basel) 2021; 13:4058. [PMID: 34439214 PMCID: PMC8394840 DOI: 10.3390/cancers13164058] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 08/05/2021] [Accepted: 08/08/2021] [Indexed: 12/12/2022] Open
Abstract
Pancreatic cancer is a leading cause of cancer death, and boron neutron capture therapy (BNCT) is one of the promising radiotherapy techniques for patients with pancreatic cancer. In this study, we evaluated the biological effectiveness of BNCT at multicellular levels using in vitro and in silico models. To recapture the phenotypic characteristic of pancreatic tumors, we developed a cell self-assembly approach with human pancreatic cancer cells Panc-1 and BxPC-3 cocultured with MRC-5 fibroblasts. On substrate with physiological stiffness, tumor cells self-assembled into 3D spheroids, and the cocultured fibroblasts further facilitated the assembly process, which recapture the influence of tumor stroma. Interestingly, after 1.2 MW neutron irradiation, lower survival rates and higher apoptosis (increasing by 4-fold for Panc-1 and 1.5-fold for BxPC-3) were observed in 3D spheroids, instead of in 2D monolayers. The unexpected low tolerance of 3D spheroids to BNCT highlights the unique characteristics of BNCT over conventional radiotherapy. The uptake of boron-containing compound boronophenylalanine (BPA) and the alteration of E-cadherin can partially contribute to the observed susceptibility. In addition to biological effects, the probability of induced α-particle exposure correlated to the multicellular organization was speculated to affect the cellular responses to BNCT. A Monte Carlo (MC) simulation was also established to further interpret the observed survival. Intracellular boron distribution in the multicellular structure and related treatment resistance were reconstructed in silico. Simulation results demonstrated that the physical architecture is one of the essential factors for biological effectiveness in BNCT, which supports our in vitro findings. In summary, we developed in vitro and in silico self-assembly 3D models to evaluate the effectiveness of BNCT on pancreatic tumors. Considering the easy-access of this 3D cell-assembly platform, this study may not only contribute to the current understanding of BNCT but is also expected to be applied to evaluate the BNCT efficacy for individualized treatment plans in the future.
Collapse
Affiliation(s)
- Lin-Sheng Yu
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan; (L.-S.Y.); (M.J.); (L.-Y.Y.)
| | - Megha Jhunjhunwala
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan; (L.-S.Y.); (M.J.); (L.-Y.Y.)
| | - Shiao-Ya Hong
- Medical Research Center, Cardinal Tien Hospital, New Taipei City 23148, Taiwan;
| | - Lin-Yen Yu
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan; (L.-S.Y.); (M.J.); (L.-Y.Y.)
| | - Wey-Ran Lin
- Department of Gastroenterology & Hepatology, Linkou Chang Gung Memorial Hospital, Taoyuan 33305, Taiwan
- Department of Medicine, Chang Gung University, Taoyuan 33302, Taiwan
| | - Chi-Shuo Chen
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan; (L.-S.Y.); (M.J.); (L.-Y.Y.)
| |
Collapse
|
3
|
WITHDRAWN: Selective enhancement of boron accumulation in tumours with intra-arterial administration of boron-entrapped water-in-oil-in-water emulsion as a novel boron carrier in VX-2 rabbit hepatic cancer model for neutron capture therapy. Pharmacotherapy 2015. [DOI: 10.1016/j.biopha.2014.12.046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
4
|
Tumor growth suppression by gadolinium-neutron capture therapy using gadolinium-entrapped liposome as gadolinium delivery agent. Biomed Pharmacother 2012; 67:451-7. [PMID: 23743325 DOI: 10.1016/j.biopha.2012.11.010] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2012] [Accepted: 11/23/2012] [Indexed: 11/21/2022] Open
Abstract
Neutron capture therapy (NCT) is a promising non-invasive cancer therapy approach and some recent NCT research has focused on using compounds containing gadolinium as an alternative to currently used boron-10 considering several advantages that gadolinium offers compared to those of boron. In this study, we evaluated gadolinium-entrapped liposome compound as neutron capture therapy agent by in vivo experiment on colon-26 tumor-bearing mice. Gadolinium compound were injected intravenously via tail vein and allowed to accumulate into tumor site. Tumor samples were taken for quantitative analysis by ICP-MS at 2, 12, and 24 h after gadolinium compound injection. Highest gadolinium concentration was observed at about 2 h after gadolinium compound injection with an average of 40.3 μg/g of wet tumor tissue. We performed neutron irradiation at JRR-4 reactor facility of Japan Atomic Energy Research Institute in Tokaimura with average neutron fluence of 2×10¹² n/cm². The experimental results showed that the tumor growth suppression of gadolinium-injected irradiated group was revealed until about four times higher compared to the control group, and no significant weight loss were observed after treatment suggesting low systemic toxicity of this compound. The gadolinium-entrapped liposome will become one of the candidates for Gd delivery system on NCT.
Collapse
|
5
|
Feasibility evaluation of neutron capture therapy for hepatocellular carcinoma using selective enhancement of boron accumulation in tumour with intra-arterial administration of boron-entrapped water-in-oil-in-water emulsion. Appl Radiat Isot 2011; 69:1854-7. [DOI: 10.1016/j.apradiso.2011.04.022] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2010] [Revised: 04/16/2011] [Accepted: 04/18/2011] [Indexed: 11/24/2022]
|
6
|
Yang F, Jin C, Jiang Y, Li J, Di Y, Ni Q, Fu D. Liposome based delivery systems in pancreatic cancer treatment: from bench to bedside. Cancer Treat Rev 2011; 37:633-642. [PMID: 21330062 DOI: 10.1016/j.ctrv.2011.01.006] [Citation(s) in RCA: 105] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2010] [Revised: 01/15/2011] [Accepted: 01/21/2011] [Indexed: 12/12/2022]
Abstract
Despite rapid advances in cancer diagnosis and treatment, pancreatic cancer remains one of the most difficult human malignancies to be treated, with a mortality rate nearly equal to its incidence. Although gemcitabine has been established as the standard first-line treatment for advanced pancreatic cancer, gemcitabine-based combination chemotherapy showed either marginal or no improvement in survival. Developments in liposomal delivery systems have facilitated the targeting of specific agents for cancer treatment. Such systems could be developed as platforms for future multi-functional theranostic nanodevices tailor-made for the combined detection of early cancer and functional drug delivery. We systemically review liposome based drug-delivery systems, which can provide improved pharmacokinetics, reduced side effects and potentially increased tumor uptake, for pancreatic cancer therapy. Novel liposomal formulations allowing for higher tumor targeting efficiencies and used in current clinical trials to treat this challenging disease are emphasized.
Collapse
Affiliation(s)
- Feng Yang
- Pancreatic Disease Institute, Department of Pancreatic Surgery, Huashan Hospital, Fudan University, Shanghai, China.
| | | | | | | | | | | | | |
Collapse
|
7
|
Fujii H, Matsuyama A, Komoda H, Sasai M, Suzuki M, Asano T, Doki Y, Kirihata M, Ono K, Tabata Y, Kaneda Y, Sawa Y, Lee CM. Cationized gelatin-HVJ envelope with sodium borocaptate improved the BNCT efficacy for liver tumors in vivo. Radiat Oncol 2011; 6:8. [PMID: 21247507 PMCID: PMC3035588 DOI: 10.1186/1748-717x-6-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2010] [Accepted: 01/20/2011] [Indexed: 11/21/2022] Open
Abstract
BACKGROUND Boron neutron capture therapy (BNCT) is a cell-selective radiation therapy that uses the alpha particles and lithium nuclei produced by the boron neutron capture reaction. BNCT is a relatively safe tool for treating multiple or diffuse malignant tumors with little injury to normal tissue. The success or failure of BNCT depends upon the 10B compound accumulation within tumor cells and the proximity of the tumor cells to the body surface. To extend the therapeutic use of BNCT from surface tumors to visceral tumors will require 10B compounds that accumulate strongly in tumor cells without significant accumulation in normal cells, and an appropriate delivery method for deeper tissues.Hemagglutinating Virus of Japan Envelope (HVJ-E) is used as a vehicle for gene delivery because of its high ability to fuse with cells. However, its strong hemagglutination activity makes HVJ-E unsuitable for systemic administration.In this study, we developed a novel vector for 10B (sodium borocaptate: BSH) delivery using HVJ-E and cationized gelatin for treating multiple liver tumors with BNCT without severe adverse events. METHODS We developed cationized gelatin conjugate HVJ-E combined with BSH (CG-HVJ-E-BSH), and evaluated its characteristics (toxicity, affinity for tumor cells, accumulation and retention in tumor cells, boron-carrying capacity to multiple liver tumors in vivo, and bio-distribution) and effectiveness in BNCT therapy in a murine model of multiple liver tumors. RESULTS CG-HVJ-E reduced hemagglutination activity by half and was significantly less toxic in mice than HVJ-E. Higher 10B concentrations in murine osteosarcoma cells (LM8G5) were achieved with CG-HVJ-E-BSH than with BSH. When administered into mice bearing multiple LM8G5 liver tumors, the tumor/normal liver ratios of CG-HVJ-E-BSH were significantly higher than those of BSH for the first 48 hours (p < 0.05). In suppressing the spread of tumor cells in mice, BNCT treatment was as effective with CG-HVJ-E-BSH as with BSH containing a 35-fold higher 10B dose. Furthermore, CG-HVJ-E-BSH significantly increased the survival time of tumor-bearing mice compared to BSH at a comparable dosage of 10B. CONCLUSION CG-HVJ-E-BSH is a promising strategy for the BNCT treatment of visceral tumors without severe adverse events to surrounding normal tissues.
Collapse
Affiliation(s)
- Hitoshi Fujii
- Department of Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Akifumi Matsuyama
- Medical Center for Translational Research, Osaka University Hospital, Osaka, Japan
| | - Hiroshi Komoda
- Department of Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Masao Sasai
- Medical Center for Translational Research, Osaka University Hospital, Osaka, Japan
| | - Minoru Suzuki
- Particle Radiation Oncology Research Center Laboratory, Research Reactor Institute, Kyoto University, Osaka, Japan
| | - Tomoyuki Asano
- Department of Agriculture, Osaka Prefectural University, Osaka, Japan
| | - Yuichiro Doki
- Department of Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | | | - Koji Ono
- Particle Radiation Oncology Research Center Laboratory, Research Reactor Institute, Kyoto University, Osaka, Japan
| | - Yasuhiko Tabata
- Department of Biomaterials, Institute for Frontier Medical Sciences, Kyoto University, Kyoto, Japan
| | - Yasufumi Kaneda
- Division of Gene Therapy Science, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Yoshiki Sawa
- Department of Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Chun Man Lee
- Department of Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
- Medical Center for Translational Research, Osaka University Hospital, Osaka, Japan
- Health Care Economics and Industrial Policy, Osaka University Graduate School of Medicine, Osaka Japan
| |
Collapse
|
8
|
Yanagie H, Kumada H, Sakurai Y, Nakamura T, Furuya Y, Sugiyama H, Ono K, Takamoto S, Eriguchi M, Takahashi H. Dosimetric evaluation of neutron capture therapy for local advanced breast cancer. Appl Radiat Isot 2009; 67:S63-6. [PMID: 19427224 DOI: 10.1016/j.apradiso.2009.03.110] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Local recurrence breast cancer is one of the most difficult conditions to cure and there is a need for new therapy. If sufficient boron compound can be targeted to the tumor, boron neutron capture therapy (BNCT) can be applied to local recurrent breast cancer. In this study, we performed a preliminary dosimetry with a phantom model of the mammary gland at Kyoto University Research Reactor (KUR), and a feasibility dosimetry with JAERI Computational Dosimetry System (JCDS) at JRR4 reactor of Japan Atomic Research Institute. We performed preliminary dosimetry of a phantom model of the mammary gland with thermal neutron irradiation (OO-0011 mode) on LiF collimation at KUR. The thermal neutron flux was 5.16 E+08 cm(-2)s(-1) at the surface of phantom. The blood boron concentration is estimated to be 30 ppm; tumor boron concentration is also estimated to be 90 ppm according to tumor/blood ratio 3 and skin/blood ratio 1.2. Tumor RBE dose is estimated to be 47 Gy/h, and skin RBE dose is 12.4 Gy/h. In case of advanced breast cancer, we performed the feasibility estimation of 3D construction of tumor according to the MRI imaging of a patient with epithermal neutron mode at JRR4. The blood boron concentration (ppm) and tumor/normal tissue ratio are estimated to be 24 and 3.5, respectively. Skin RBE dose is restricted to 10 Gy/h, the maximum tumor RBE dose, minimum tumor RBE dose, and mean tumor RBE dose are 42.2, 11.3, and 28.9 Gy-Eq, respectively, in half hour irradiation. In this study, we showed the possibility to apply BNCT to local recurrent breast cancer. We can irradiate tumors selectively and as safely as possible, reducing the effects on neighboring healthy tissues.
Collapse
Affiliation(s)
- H Yanagie
- Department of Nuclear Engineering and Management, Graduate School of Engineering, The University of Tokyo, Tokyo, Japan.
| | | | | | | | | | | | | | | | | | | |
Collapse
|