1
|
Chang X, Cheng Y, Wang X, Wang Y, Liu X, Han T, Gao Z, Zhou H. A novel ultrasensitive and fast aptamer biosensor of SEB based on AuNPs-assisted metal-enhanced fluorescence. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 858:159977. [PMID: 36347282 DOI: 10.1016/j.scitotenv.2022.159977] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 11/01/2022] [Accepted: 11/01/2022] [Indexed: 06/16/2023]
Abstract
A fluorescent biosensor strategy was developed in combination with immunomagnetic separation for rapid and sensitive detection of staphylococcal enterotoxin B (SEB). Magnetic nanoparticles (MNPs) modified with aptamer of SEB could capture the SEB. Then the gold nanoparticles (AuNPs) fluorescent probe was added and a "sandwich structure" was formed between AuNPs, SEB and MNPs. The MNPs-SEB-AuNPs structure could be separated with an additional magnetic field, which resulted the lower signals of AuNPs fluorescent probe. In optimal conditions, the current method displayed a broad quantitative range from 100 to 107 fg/mL and the limit of detection was 3.43 fg/mL. The recovery of SEB-spiked milk samples ranged from 92.00 to 119.00 %, which revealed that the developed method had great accuracy. Furthermore, the method was fast and economical for ultrasensitive detection. Therefore, the fluorescent biosensor based on MNPs-AuNPs is promising for the detection of other environmental and food pollutants.
Collapse
Affiliation(s)
- Xueyu Chang
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, People's Republic of China
| | - Yaqian Cheng
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, People's Republic of China
| | - Xinke Wang
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, People's Republic of China
| | - Yonghui Wang
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, People's Republic of China
| | - Xueli Liu
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, People's Republic of China
| | - Tie Han
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, People's Republic of China
| | - Zhixian Gao
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, People's Republic of China.
| | - Huanying Zhou
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, People's Republic of China.
| |
Collapse
|
2
|
Carvalho PM, Makowski M, Domingues MM, Martins IC, Santos NC. Lipid membrane-based therapeutics and diagnostics. Arch Biochem Biophys 2021; 704:108858. [PMID: 33798534 DOI: 10.1016/j.abb.2021.108858] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 03/20/2021] [Accepted: 03/22/2021] [Indexed: 12/29/2022]
Abstract
Success rates in drug discovery are extremely low, and the imbalance between new drugs entering clinical research and their approval is steadily widening. Among the causes of the failure of new therapeutic agents are the lack of safety and insufficient efficacy. On the other hand, timely disease diagnosis may enable an early management of the disease, generally leading to better and less costly outcomes. Several strategies have been explored to overcome the barriers for drug development and facilitate diagnosis. Using lipid membranes as platforms for drug delivery or as biosensors are promising strategies, due to their biocompatibility and unique physicochemical properties. We examine some of the lipid membrane-based strategies for drug delivery and diagnostics, including their advantages and shortcomings. Regarding synthetic lipid membrane-based strategies for drug delivery, liposomes are the archetypic example of a successful approach, already with a long period of well-succeeded clinical application. The use of lipid membrane-based structures from biological sources as drug carriers, currently under clinical evaluation, is also discussed. These biomimetic strategies can enhance the in vivo lifetime of drug and delivery system by avoiding fast clearance, consequently increasing their therapeutic window. The strategies under development using lipid membranes for diagnostic purposes are also reviewed.
Collapse
Affiliation(s)
- Patrícia M Carvalho
- Instituto de Medicina Molecular, Faculdade de Medicina, Universidade de Lisboa, Av. Prof. Egas Moniz, 1649-028, Lisbon, Portugal
| | - Marcin Makowski
- Instituto de Medicina Molecular, Faculdade de Medicina, Universidade de Lisboa, Av. Prof. Egas Moniz, 1649-028, Lisbon, Portugal
| | - Marco M Domingues
- Instituto de Medicina Molecular, Faculdade de Medicina, Universidade de Lisboa, Av. Prof. Egas Moniz, 1649-028, Lisbon, Portugal
| | - Ivo C Martins
- Instituto de Medicina Molecular, Faculdade de Medicina, Universidade de Lisboa, Av. Prof. Egas Moniz, 1649-028, Lisbon, Portugal
| | - Nuno C Santos
- Instituto de Medicina Molecular, Faculdade de Medicina, Universidade de Lisboa, Av. Prof. Egas Moniz, 1649-028, Lisbon, Portugal.
| |
Collapse
|
3
|
Nikoleli GP, Nikolelis DP, Siontorou CG, Nikolelis MT, Karapetis S. The Application of Lipid Membranes in Biosensing. MEMBRANES 2018; 8:E108. [PMID: 30441848 PMCID: PMC6316677 DOI: 10.3390/membranes8040108] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 11/01/2018] [Accepted: 11/12/2018] [Indexed: 12/20/2022]
Abstract
The exploitation of lipid membranes in biosensors has provided the ability to reconstitute a considerable part of their functionality to detect trace of food toxicants and environmental pollutants. This paper reviews recent progress in biosensor technologies based on lipid membranes suitable for food quality monitoring and environmental applications. Numerous biosensing applications based on lipid membrane biosensors are presented, putting emphasis on novel systems, new sensing techniques, and nanotechnology-based transduction schemes. The range of analytes that can be currently using these lipid film devices that can be detected include, insecticides, pesticides, herbicides, metals, toxins, antibiotics, microorganisms, hormones, dioxins, etc. Technology limitations and future prospects are discussed, focused on the evaluation/validation and eventually commercialization of the proposed lipid membrane-based biosensors.
Collapse
Affiliation(s)
- Georgia-Paraskevi Nikoleli
- Laboratory of Inorganic & Analytical Chemistry, School of Chemical Engineering, Dept 1, Chemical Sciences, National Technical University of Athens, 9 Iroon Polytechniou St., 15780 Athens, Greece.
| | - Dimitrios P Nikolelis
- Laboratory of Environmental Chemistry, Department of Chemistry, University of Athens, Panepistimiopolis-Kouponia, 15771 Athens, Greece.
| | - Christina G Siontorou
- Laboratory of Simulation of Industrial Processes, Department of Industrial Management and Technology, School of Maritime and Industry, University of Piraeus, 18534 Pireus, Greece.
| | - Marianna-Thalia Nikolelis
- Laboratory of Environmental Chemistry, Department of Chemistry, University of Athens, Panepistimiopolis-Kouponia, 15771 Athens, Greece.
| | - Stephanos Karapetis
- Laboratory of Inorganic & Analytical Chemistry, School of Chemical Engineering, Dept 1, Chemical Sciences, National Technical University of Athens, 9 Iroon Polytechniou St., 15780 Athens, Greece.
| |
Collapse
|
4
|
van den Hurk R, Evoy S. A Review of Membrane-Based Biosensors for Pathogen Detection. SENSORS 2015; 15:14045-78. [PMID: 26083229 PMCID: PMC4507637 DOI: 10.3390/s150614045] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2015] [Revised: 05/29/2015] [Accepted: 06/05/2015] [Indexed: 01/14/2023]
Abstract
Biosensors are of increasing interest for the detection of bacterial pathogens in many applications such as human, animal and plant health, as well as food and water safety. Membranes and membrane-like structures have been integral part of several pathogen detection platforms. Such structures may serve as simple mechanical support, function as a part of the transduction mechanism, may be used to filter out or concentrate pathogens, and may be engineered to specifically house active proteins. This review focuses on membrane materials, their associated biosensing applications, chemical linking procedures, and transduction mechanisms. The sensitivity of membrane biosensors is discussed, and the state of the field is evaluated and summarized.
Collapse
Affiliation(s)
- Remko van den Hurk
- Department of Electrical and Computer Engineering, University of Alberta Edmonton, Alberta, AB T6G 2V4, Canada.
| | - Stephane Evoy
- Department of Electrical and Computer Engineering, University of Alberta Edmonton, Alberta, AB T6G 2V4, Canada.
| |
Collapse
|
5
|
Liu N, Zhao Z, Chen Y, Gao Z. Rapid Detection of Staphylococcal Enterotoxin B by Two-Dimensional Molecularly Imprinted Film-Coated Quartz Crystal Microbalance. ANAL LETT 2012. [DOI: 10.1080/00032719.2011.633186] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
6
|
Zelada-Guillén GA, Sebastián-Avila JL, Blondeau P, Riu J, Rius FX. Label-free detection of Staphylococcus aureus in skin using real-time potentiometric biosensors based on carbon nanotubes and aptamers. Biosens Bioelectron 2011; 31:226-32. [PMID: 22154169 DOI: 10.1016/j.bios.2011.10.021] [Citation(s) in RCA: 123] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2011] [Revised: 10/10/2011] [Accepted: 10/13/2011] [Indexed: 11/16/2022]
Abstract
In this paper we report the first biosensor that is able to detect Staphylococcus aureus in real-time. A network of single-walled carbon nanotubes (SWCNTs) acts as an ion-to-electron potentiometric transducer and anti-S. aureus aptamers are the recognition element. Carbon nanotubes were functionalized with aptamers using two different approaches: (1) non-covalent adsorption of drop-casted pyrenil-modified aptamers onto the external walls of the SWCNTs; and (2) covalent bond formation between amine-modified aptamers and carboxylic groups previously introduced by oxidation at the ends of the SWCNTs. Both of these approaches yielded functional biosensors but there were large differences in the minimum detectable bacteria concentration and sensitivity values. With covalent functionalization, the minimum concentration detected was 8×10(2)colony-forming units (CFU)/mL and the sensitivity was 0.36 mV/Decade. With the non-covalent approach, the sensitivity was higher (1.52 mV/Decade) but the minimum concentration detected was greatly affected (10(7) CFU/mL). In both cases, potential as a function of Decade of bacteria concentration was linear. Functional biosensors were used to test real samples from freshly excised pig skin, contaminated with the target microorganism, as a surrogate for human skin.
Collapse
Affiliation(s)
- Gustavo A Zelada-Guillén
- Department of Analytical and Organic Chemistry, Universitat Rovira i Virgili, Campus Sescelades, C/Marcel·lí Domingo s/n, 43007 Tarragona, Spain.
| | | | | | | | | |
Collapse
|
7
|
|
8
|
Sensitive detection of lip genes by electrochemical DNA sensor and its application in polymerase chain reaction amplicons from Phanerochaete chrysosporium. Biosens Bioelectron 2008; 24:1474-9. [PMID: 19010661 DOI: 10.1016/j.bios.2008.09.031] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2008] [Revised: 09/21/2008] [Accepted: 09/24/2008] [Indexed: 11/23/2022]
Abstract
An electrochemical DNA sensor based on the sandwich hybridization recognition of target sequence of lignin peroxidase (lip) genes on a gold electrode was developed. A monolayer of thiolated capture probe was formed on a gold electrode through self-assembling. Following hybridizations with target nucleic acid and biotinylated detection probe, streptavidin-horseradish peroxidase (HRP) conjugate was applied to the electrode. The DNA conformation and surface coverage on electrode were characterized by impedance spectroscopy and square wave voltammetry. The experimental variables were optimized to maximize the hybridization efficiency, detection sensitivity and speed up the assay time. The amperometric current response to HRP-catalyzed reaction was linearly related to the natural logarithm of the target nucleic acid concentration in the range from 0.6 to 30 nM, with the correlation coefficient of 0.9722. The detection limit was 0.03 nM. Synthesized oligonucleotide as well as Phanerochaete chrysosporium lip gene fragments amplified using polymerase chain reaction and digested by restriction endonucleases were tested. The DNA sensor exhibited good precision, stability, sensitivity, and selectivity, and discriminated satisfactorily against mismatched nucleic acid samples of similar lengths.
Collapse
|
9
|
Nguyen BTT, Ting EZC, Toh CS. Development of a biomimetic nanoporous membrane for the selective transport of charged proteins. BIOINSPIRATION & BIOMIMETICS 2008; 3:035008. [PMID: 18667763 DOI: 10.1088/1748-3182/3/3/035008] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
We report the use of a micrometer-thick platinum-coated nanoporous membrane for the separation of differently charged proteins. A high field strength of about 25 kV m(-1) was applied, using very low transmembrane potentials of +/-1.5 V between the platinum-coated membranes. The system mimics the cell membrane function of facilitated transport for specific solutes. The selectivity for Lys:BSA:Mb in a mixed protein solution could be tuned readily between the flux ratios of 2:2:1 and 96:1:12 respectively, by simple variation of the transmembrane potentials from +1.5 V to -1.5 V. The experimental fluxes agreed closely with calculated fluxes derived from a simple electrophoresis-potential shielding model at favourable transmembrane potentials.
Collapse
Affiliation(s)
- Binh T T Nguyen
- Department of Chemistry, Faculty of Science, National University of Singapore, Singapore 117543
| | | | | |
Collapse
|
10
|
A novel one-step method to incorporate ss DNA into bilayer lipid membranes supported on an agar electrode. Electrochem commun 2008. [DOI: 10.1016/j.elecom.2008.02.039] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|