1
|
Wang X, Yang C, Jiang W, Zhang M, Li R, Lin Y, Wang Q. Rapid quantitative detection of okadaic acid in shellfish using lanthanide-labelled fluorescent-nanoparticle immunochromatographic test strips. Food Control 2023. [DOI: 10.1016/j.foodcont.2023.109635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
2
|
Li X, Cheng Y, Xu R, Zhang Z, Qi X, Chen L, Zhu M. A smartphone-assisted microarray immunosensor coupled with GO-based multi-stage signal amplification strategy for high-sensitivity detection of okadaic acid. Talanta 2022; 247:123567. [PMID: 35623247 DOI: 10.1016/j.talanta.2022.123567] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 05/11/2022] [Accepted: 05/16/2022] [Indexed: 11/28/2022]
Abstract
Okadaic acid (OA) is one of the main virulence factors of diarrheal shellfish toxins (DSP), which can cause acute carcinogenic or teratogenic effects after ingestion of contaminated shellfish. Therefore, high-sensitivity and fast detection of OA is a key to preventing the occurrence of safety accidents. In this paper, we effectively established a smartphone-assisted microarray immunosensor combined with an indirect competitive ELISA (iELISA) for quantitative colorimetric detection of OA. To further improve the detection sensitivity and match the smartphone imaging, a novel graphene oxide (GO) composite probe was developed to realize the multi-stage signal amplification. The system exhibited a wide linear range for the detection of OA (0.02-33.6 ng ·mL-1) with low detection limit of 0.02 ng ·mL-1. The recovery of OA in spiked shellfish samples was in the range of 80%-103.5%, which indicates the good applicability of this biosensor. The whole detection system has advantages of simplicity, low cost, high sensitivity and portability, which is expected to be a powerful alternative tool for on-site detecting and early warning of the pollution of marine products.
Collapse
Affiliation(s)
- Xiaotong Li
- Institute of Eco-Environmental Forensics, Qingdao Institute of Humanities and Social Sciences, Shandong University, China
| | - Yongqiang Cheng
- Institute of Eco-Environmental Forensics, Qingdao Institute of Humanities and Social Sciences, Shandong University, China.
| | - Ranran Xu
- Institute of Eco-Environmental Forensics, Qingdao Institute of Humanities and Social Sciences, Shandong University, China
| | - Ziwei Zhang
- Institute of Eco-Environmental Forensics, Qingdao Institute of Humanities and Social Sciences, Shandong University, China
| | - Xiaoxiao Qi
- Institute of Eco-Environmental Forensics, Qingdao Institute of Humanities and Social Sciences, Shandong University, China
| | - Longyu Chen
- Institute of Eco-Environmental Forensics, Qingdao Institute of Humanities and Social Sciences, Shandong University, China
| | - Meijia Zhu
- Institute of Eco-Environmental Forensics, Qingdao Institute of Humanities and Social Sciences, Shandong University, China
| |
Collapse
|
3
|
Kweon SY, Park JP, Park CY, Park TJ. Graphene Oxide-Mediated Fluorometric Aptasensor for Okadaic Acid Detection. BIOCHIP JOURNAL 2022. [DOI: 10.1007/s13206-022-00056-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
4
|
Louzao MC, Vilariño N, Vale C, Costas C, Cao A, Raposo-Garcia S, Vieytes MR, Botana LM. Current Trends and New Challenges in Marine Phycotoxins. Mar Drugs 2022; 20:md20030198. [PMID: 35323497 PMCID: PMC8950113 DOI: 10.3390/md20030198] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 03/04/2022] [Accepted: 03/05/2022] [Indexed: 02/04/2023] Open
Abstract
Marine phycotoxins are a multiplicity of bioactive compounds which are produced by microalgae and bioaccumulate in the marine food web. Phycotoxins affect the ecosystem, pose a threat to human health, and have important economic effects on aquaculture and tourism worldwide. However, human health and food safety have been the primary concerns when considering the impacts of phycotoxins. Phycotoxins toxicity information, often used to set regulatory limits for these toxins in shellfish, lacks traceability of toxicity values highlighting the need for predefined toxicological criteria. Toxicity data together with adequate detection methods for monitoring procedures are crucial to protect human health. However, despite technological advances, there are still methodological uncertainties and high demand for universal phycotoxin detectors. This review focuses on these topics, including uncertainties of climate change, providing an overview of the current information as well as future perspectives.
Collapse
Affiliation(s)
- Maria Carmen Louzao
- Departamento de Farmacologia, Facultad de Veterinaria, Universidade de Santiago de Compostela, 27002 Lugo, Spain; (N.V.); (C.V.); (C.C.); (A.C.); (S.R.-G.)
- Correspondence: (M.C.L.); (L.M.B.)
| | - Natalia Vilariño
- Departamento de Farmacologia, Facultad de Veterinaria, Universidade de Santiago de Compostela, 27002 Lugo, Spain; (N.V.); (C.V.); (C.C.); (A.C.); (S.R.-G.)
| | - Carmen Vale
- Departamento de Farmacologia, Facultad de Veterinaria, Universidade de Santiago de Compostela, 27002 Lugo, Spain; (N.V.); (C.V.); (C.C.); (A.C.); (S.R.-G.)
| | - Celia Costas
- Departamento de Farmacologia, Facultad de Veterinaria, Universidade de Santiago de Compostela, 27002 Lugo, Spain; (N.V.); (C.V.); (C.C.); (A.C.); (S.R.-G.)
| | - Alejandro Cao
- Departamento de Farmacologia, Facultad de Veterinaria, Universidade de Santiago de Compostela, 27002 Lugo, Spain; (N.V.); (C.V.); (C.C.); (A.C.); (S.R.-G.)
| | - Sandra Raposo-Garcia
- Departamento de Farmacologia, Facultad de Veterinaria, Universidade de Santiago de Compostela, 27002 Lugo, Spain; (N.V.); (C.V.); (C.C.); (A.C.); (S.R.-G.)
| | - Mercedes R. Vieytes
- Departamento de Fisiologia, Facultad de Veterinaria, Universidade de Santiago de Compostela, 27002 Lugo, Spain;
| | - Luis M. Botana
- Departamento de Farmacologia, Facultad de Veterinaria, Universidade de Santiago de Compostela, 27002 Lugo, Spain; (N.V.); (C.V.); (C.C.); (A.C.); (S.R.-G.)
- Correspondence: (M.C.L.); (L.M.B.)
| |
Collapse
|
5
|
Park S, Seo S, Lee NS, Yoon YH, Yang H. Sensitive electrochemical immunosensor using a bienzymatic system consisting of β-galactosidase and glucose dehydrogenase. Analyst 2021; 146:3880-3887. [PMID: 33983348 DOI: 10.1039/d1an00562f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Bienzymatic systems are often used with electrochemical affinity biosensors to achieve high signal levels and/or low background levels. It is important to select two enzymes whose reactions do not exhibit mutual interference but have similar optimal conditions. Here, we report a sensitive electrochemical immunosensor based on a bienzymatic system consisting of β-galactosidase (Gal, a hydrolase enzyme) and flavin adenine dinucleotide-dependent glucose dehydrogenase (FAD-GDH, a redox enzyme). Both enzymes showed high activities at neutral pH, the reactions catalyzed by them did not exhibit mutual interference, and the electrochemical-enzymatic redox cycling based on FAD-GDH coupled with enzymatic amplification by Gal enabled high signal amplification. Among the three amino-hydroxy-naphthalenes and 4-aminophenol (potential Gal products), 4-amino-1-naphthol showed the highest signal amplification. Glucose, as an electro-inactive, stable reducing agent for redox cycling, helped in achieving low background levels. Our bienzymatic system could detect parathyroid hormone at a detection limit of ∼0.2 pg mL-1, implying that it can be used for highly sensitive electrochemical detection of parathyroid hormone and other biomarkers in human serum.
Collapse
Affiliation(s)
- Seonhwa Park
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea.
| | - Seungah Seo
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea.
| | | | | | - Haesik Yang
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea.
| |
Collapse
|
6
|
Barsan MM, Sanz CG, Onea M, Diculescu VC. Immobilized Antibodies on Mercaptophenylboronic Acid Monolayers for Dual-Strategy Detection of 20S Proteasome. SENSORS (BASEL, SWITZERLAND) 2021; 21:2702. [PMID: 33921330 PMCID: PMC8068791 DOI: 10.3390/s21082702] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 04/05/2021] [Accepted: 04/08/2021] [Indexed: 11/16/2022]
Abstract
A dual strategy for the electrochemical detection for 20S proteasome (20S) is proposed, based on the oriented immobilization of a capture monoclonal antibody (Abβ) on a self-assembled monolayer of 4-mercaptophenylboronic acid (4-MPBA) on gold electrodes, which led to the Au/4-MPBA/Abβ immunosensor. The methodology comprises the correlation of 20S concentration with (i) its proteolytic activity toward the Z-LLE-AMC substrate, using the Au/4-MPBA/Abβ/20S, and (ii) the enzymatic activity of an alkaline phosphatase (AlkP) from the AlkP-labeled secondary antibody (Abcore-AlkP), which involves the conversion of aminophenylphosphate to the electroactive aminophenol using Au/4-MPBA/Abβ/20S/Abcore-AlkP. The step-by-step construction of the immunosensor and the interactions at its surface were evaluated by surface plasmon resonance and gravimetric analysis with quartz crystal microbalance, showing a high affinity between both antibodies and 20S. Morphological analysis by scanning electron microscopy demonstrated a pattern of parallel lines upon immobilization of Abβ on 4-MPBA and morphological changes to a well-organized granular structure upon binding of 20S. A voltametric and impedimetric characterization was performed after each step in the immunosensor construction. The two detection strategies were evaluated. It was shown that the immunosensor responds linearly with 20S concentration in the range between 5 and 100 µg mL-1, which corresponds to proteasome levels in serum in the case of diverse pathological situations, and LoD values of 1.4 and 0.2 µg mL-1 were calculated for the detection strategies. The immunosensor was applied to the detection of 20S in serum samples with recovery values ranging from 101 to 103%.
Collapse
Affiliation(s)
- Madalina M. Barsan
- National Institute of Materials Physics, Atomistilor 405A, 077125 Măgurele, Romania; (M.M.B.); (C.G.S.); (M.O.)
| | - Caroline G. Sanz
- National Institute of Materials Physics, Atomistilor 405A, 077125 Măgurele, Romania; (M.M.B.); (C.G.S.); (M.O.)
| | - Melania Onea
- National Institute of Materials Physics, Atomistilor 405A, 077125 Măgurele, Romania; (M.M.B.); (C.G.S.); (M.O.)
- Faculty of Physics, University of Bucharest, Atomistilor 405, 077125 Măgurele, Romania
| | - Victor C. Diculescu
- National Institute of Materials Physics, Atomistilor 405A, 077125 Măgurele, Romania; (M.M.B.); (C.G.S.); (M.O.)
| |
Collapse
|
7
|
Verma M, Chaudhary M, Singh A, Kaur N, Singh N. Naphthalimide-gold-based nanocomposite for the ratiometric detection of okadaic acid in shellfish. J Mater Chem B 2021; 8:8405-8413. [PMID: 32966537 DOI: 10.1039/d0tb01195a] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Okadaic acid (OA) is one of the known marine biotoxins produced by various dinoflagellates and exists in seafood such as shellfish. The consumption of contaminated shellfish with OA leads to diarrheic shellfish poisoning (DSP), which results in the inhibition of protein phosphatase enzymes in humans. This poisoning can cause immunotoxicity and tumor promotion due to the accumulation of okadaic acid in more than the allowed limit in bivalve molluscs. The reported methods for the detection of okadaic acid include mouse bioassays, immunoassays, chromatography coupled with spectroscopic techniques, electrochemical sensors and immunosensors. We have developed a naphthalimide-gold-based nanocomposite for the detection of okadaic acid. Individually, the organic nanoparticles (ONPs) of synthesized naphthalimide-based receptors and gold-coated ONPs are less sensitive for detection. However, fabrication of the composite of Au@ONPs and ONPs enhance the sensing properties and selectivity. The composite shows a ratiometric response in the UV-Vis absorption spectrum and quenching in the fluorescence profile with a detection limit of 20 nM for OA in aqueous medium. In cyclic voltammetry, a shift was observed in the cathodic peak (-0.532 V to -0.618 V) as well as in the anodic peak (-0.815 V to -0.847 V) with the addition of okadaic acid. To study the quick binding of the composite with OA, a time response experiment was performed. Also, the developed sensor retains its sensing ability in the pH range of 5-9 and in high salt conditions. Our developed composite can be used for the detection of OA in real applications.
Collapse
Affiliation(s)
- Meenakshi Verma
- Department of UCRD, Chandigarh University, Ghraun, Mohali, 140413, India
| | - Monika Chaudhary
- Centre for Biomedical Engineering, Indian Institute of Technology Ropar, Roopnagar, Punjab-140001, India
| | - Amanpreet Singh
- Department of Chemistry, Indian Institute of Technology Ropar, Roopnagar, Punjab-140001, India.
| | - Navneet Kaur
- Department of Chemistry, Panjab University, Chandigarh - 160014, India.
| | - Narinder Singh
- Department of Chemistry, Indian Institute of Technology Ropar, Roopnagar, Punjab-140001, India.
| |
Collapse
|
8
|
Emerging strategies to enhance the sensitivity of competitive ELISA for detection of chemical contaminants in food samples. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115861] [Citation(s) in RCA: 48] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
9
|
Antunes J, Justino C, da Costa JP, Cardoso S, Duarte AC, Rocha-Santos T. Graphene immunosensors for okadaic acid detection in seawater. Microchem J 2018. [DOI: 10.1016/j.microc.2018.01.041] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
10
|
Leonardo S, Toldrà A, Rambla-Alegre M, Fernández-Tejedor M, Andree KB, Ferreres L, Campbell K, Elliott CT, O'Sullivan CK, Pazos Y, Diogène J, Campàs M. Self-assembled monolayer-based immunoassays for okadaic acid detection in seawater as monitoring tools. MARINE ENVIRONMENTAL RESEARCH 2018; 133:6-14. [PMID: 29174400 DOI: 10.1016/j.marenvres.2017.11.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2017] [Revised: 11/10/2017] [Accepted: 11/12/2017] [Indexed: 06/07/2023]
Abstract
Rapid and cost-effective methods to monitor the presence of diarrhetic shellfish poisoning (DSP) toxins in seawater samples in an easy and reliable manner are required to protect human health and avoid economic losses to shellfish industry. Immunoassays for the detection of okadaic acid (OA) and dinophysistoxin-1 and dinophysistoxin-2 are developed by immobilising OA on self-assembled monothiols or dithiols in an ordered and oriented way, providing an effective limit of detection of ∼1 ng OA equiv./mL seawater. The immunoassays are applied to the analysis of the particulate fraction of seawater samples from two Catalan harbours (NW Mediterranean) and samples collected periodically from the Galician Rias (E Atlantic), as well as a reference mussel sample. Results are in agreement with LC-MS/MS and the certified values. OA concentration in seawater correlates with Dinophysis cell abundance, with a 1-2 weeks lag. The immunoassays provide powerful high-throughput analytical methods potentially applicable as alternative monitoring tools.
Collapse
Affiliation(s)
- Sandra Leonardo
- IRTA, Ctra. Poble Nou, Km. 5.5, 43540 Sant Carles de la Ràpita, Spain
| | - Anna Toldrà
- IRTA, Ctra. Poble Nou, Km. 5.5, 43540 Sant Carles de la Ràpita, Spain
| | | | | | - Karl B Andree
- IRTA, Ctra. Poble Nou, Km. 5.5, 43540 Sant Carles de la Ràpita, Spain
| | - Laura Ferreres
- IRTA, Ctra. Poble Nou, Km. 5.5, 43540 Sant Carles de la Ràpita, Spain
| | - Katrina Campbell
- Institute for Global Food Security, School of Biological Sciences, Queen's University, Stranmillis Road, Belfast, BT9 5AG, Northern Ireland, United Kingdom
| | - Christopher T Elliott
- Institute for Global Food Security, School of Biological Sciences, Queen's University, Stranmillis Road, Belfast, BT9 5AG, Northern Ireland, United Kingdom
| | - Ciara K O'Sullivan
- Departament d'Enginyeria Química, Universitat Rovira i Virgili, Av. Països Catalans, 26, 43007 Tarragona, Spain; Institució Catalana de Recerca i Estudis Avançats, Pg. Lluís Companys, 23, 08010 Barcelona, Spain
| | - Yolanda Pazos
- INTECMAR, Peirao de Vilaxoán, s/n, 36611 Vilagarcía de Arousa, Spain
| | - Jorge Diogène
- IRTA, Ctra. Poble Nou, Km. 5.5, 43540 Sant Carles de la Ràpita, Spain
| | - Mònica Campàs
- IRTA, Ctra. Poble Nou, Km. 5.5, 43540 Sant Carles de la Ràpita, Spain.
| |
Collapse
|
11
|
Kang C, Kang J, Lee NS, Yoon YH, Yang H. DT-Diaphorase as a Bifunctional Enzyme Label That Allows Rapid Enzymatic Amplification and Electrochemical Redox Cycling. Anal Chem 2017; 89:7974-7980. [PMID: 28696095 DOI: 10.1021/acs.analchem.7b01223] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
The most common enzyme labels in enzyme-linked immunosorbent assays are alkaline phosphatase and horseradish peroxidase, which, however, have some limitations for use in electrochemical immunosensors. This Article reports that the small and thermostable DT-diaphorase (DT-D) and electrochemically inactive 4-nitroso-1-naphthol (4-NO-1-N) can be used as a bifunctional enzyme label and a rapidly reacting substrate, respectively, for electrochemical immunosensors. This enzyme-substrate combination allows high signal amplification via rapid enzymatic amplification and electrochemical redox cycling. DT-D can convert an electrochemically inactive nitroso or nitro compound into an electrochemically active amine compound, which can then be involved in electrochemical-chemical (EC) and electrochemical-enzymatic (EN) redox cycling. Six nitroso and nitro compounds are tested in terms of signal-to-background ratio. Among them, 4-NO-1-N exhibits the highest signal-to-background ratio. The electrochemical immunosensor using DT-D and 4-NO-1-N detects parathyroid hormone (PTH) in phosphate-buffered saline containing bovine serum albumin over a wide range of concentrations with a low detection limit of 2 pg/mL. When the PTH concentration in clinical serum samples is measured using the developed immunosensor, the calculated concentrations are in good agreement with the concentrations obtained using a commercial instrument. Thus, the use of DT-D as an enzyme label is highly promising for sensitive electrochemical detection and point-of-care testing.
Collapse
Affiliation(s)
- Cheolho Kang
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University , Busan 46241, Korea
| | - Juyeon Kang
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University , Busan 46241, Korea
| | | | | | - Haesik Yang
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University , Busan 46241, Korea
| |
Collapse
|
12
|
Pan Y, Wan Z, Zhong L, Li X, Wu Q, Wang J, Wang P. Label-free okadaic acid detection using growth of gold nanoparticles in sensor gaps as a conductive tag. Biomed Microdevices 2017; 19:33. [DOI: 10.1007/s10544-017-0162-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
13
|
Marine Toxins Analysis for Consumer Protection. RECENT ADVANCES IN THE ANALYSIS OF MARINE TOXINS 2017. [DOI: 10.1016/bs.coac.2017.07.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
14
|
Wu H, Ohnuki H, Ota S, Murata M, Yoshiura Y, Endo H. New approach for monitoring fish stress: A novel enzyme-functionalized label-free immunosensor system for detecting cortisol levels in fish. Biosens Bioelectron 2016; 93:57-64. [PMID: 27771136 DOI: 10.1016/j.bios.2016.10.001] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2016] [Revised: 10/02/2016] [Accepted: 10/03/2016] [Indexed: 11/27/2022]
Abstract
Fishes display a wide variation in their physiological responses to stress, which is clearly evident in the plasma corticosteroid changes, chiefly cortisol levels in fish. As a well-known indicator of fish stress, a simple and rapid method for detecting cortisol changes especially sudden increases is desired. In this study, we describe an enzyme-functionalized label-free immunosensor system for detecting fish cortisol levels. Detection of cortisol using amperometry was achieved by immobilizing both anti-cortisol antibody (selective detection of cortisol) and glucose oxidase (signal amplification and non-toxic measurement) on an Au electrode surface with a self-assembled monolayer. This system is based on the maximum glucose oxidation output current change induced by the generation of a non-conductive antigen-antibody complex, which depends on the levels of cortisol in the sample. The immunosensor responded to cortisol levels with a linear decrease in the current in the range of 1.25-200ngml-1 (R=0.964). Since the dynamic range of the sensor can cover the normal range of plasma cortisol in fish, the samples obtained from the fish did not need to be diluted. Further, electrochemical measurement of one sample required only ~30min. The sensor system was applied to determine the cortisol levels in plasma sampled from Nile tilapia (Oreochromis niloticus), which were then compared with levels of the same samples determined using the conventional method (ELISA). Values determined using both methods were well correlated. These findings suggest that the proposed label-free immunosensor could be useful for rapid and convenient analysis of cortisol levels in fish without sample dilution. We also believe that the proposed system could be integrated in a miniaturized potentiostat for point-of-care cortisol detection and useful as a portable diagnostic in fish farms in the future.
Collapse
Affiliation(s)
- Haiyun Wu
- Graduate School of Marine Science and Technology, Tokyo University of Marine Science and Technology, 4-5-7, Konan, Minato-ku, Tokyo 108-8477, Japan
| | - Hitoshi Ohnuki
- Graduate School of Marine Science and Technology, Tokyo University of Marine Science and Technology, 2-1-6, Etchujima, Koto-ku, Tokyo 135-8533, Japan
| | - Shirei Ota
- Graduate School of Marine Science and Technology, Tokyo University of Marine Science and Technology, 4-5-7, Konan, Minato-ku, Tokyo 108-8477, Japan
| | - Masataka Murata
- Hokkaido Industrial Technology Center, 379 Kikyo-cho, Hakodate, Hokkaido 041-0801, Japan
| | - Yasutoshi Yoshiura
- Yashima station, Stock Enhancement and Management Department, National Research Institute of Fisheries and Enhancement of Inland Sea, Japan Fisheries Research and Education Agency, 243 Yashima-higashi, Takamatsu, Kagawa 761-0111, Japan
| | - Hideaki Endo
- Graduate School of Marine Science and Technology, Tokyo University of Marine Science and Technology, 4-5-7, Konan, Minato-ku, Tokyo 108-8477, Japan.
| |
Collapse
|
15
|
Duffy GF, Moore EJ. Electrochemical Immunosensors for Food Analysis: A Review of Recent Developments. ANAL LETT 2016. [DOI: 10.1080/00032719.2016.1167900] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
16
|
Kokkinos C, Economou A, Prodromidis MI. Electrochemical immunosensors: Critical survey of different architectures and transduction strategies. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2015.11.020] [Citation(s) in RCA: 96] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
17
|
Gu H, Duan N, Wu S, Hao L, Xia Y, Ma X, Wang Z. Graphene oxide-assisted non-immobilized SELEX of okdaic acid aptamer and the analytical application of aptasensor. Sci Rep 2016; 6:21665. [PMID: 26898784 PMCID: PMC4761938 DOI: 10.1038/srep21665] [Citation(s) in RCA: 59] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2015] [Accepted: 01/28/2016] [Indexed: 12/25/2022] Open
Abstract
Okadaic acid (OA) is a low-molecular-weight marine toxin from shellfish that causes abdominal pain, vomiting and diarrhea, i.e., diarrheic shellfish poisoning. In this study, a ssDNA aptamer that specifically binds to OA with high affinity was obtained via Systematic Evolution of Ligands by Exponential Enrichment (SELEX) assisted by graphene oxide (GO). This aptamer was then applied to fabricate a novel direct competitive enzyme-linked aptamer assay (ELAA). At the optimized conditions, this ELAA method showed a low detection limit (LOD of 0.01 ng/mL), wide linear range (from 0.025 to 10 ng/mL), good recovery rate (92.86–103.34% in OA-spiked clam samples) and repeatability (RSD of 2.28–4.53%). The proposed method can be used to detect OA in seafood products with high sensitivity and can potentially be adapted for the determination of other small molecular analytes.
Collapse
Affiliation(s)
- Huajie Gu
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China
| | - Nuo Duan
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China
| | - Shijia Wu
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China
| | - Liling Hao
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China
| | - Yu Xia
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China
| | - Xiaoyuan Ma
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China
| | - Zhouping Wang
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China
| |
Collapse
|
18
|
Stipić F, Burić P, Jakšić Ž, Pletikapić G, Dutour Sikirić M, Zgrablić G, Frkanec L, Lyons DM. Antibody-based donor-acceptor spatial reconfiguration in decorated lanthanide-doped nanoparticle colloids for the quantification of okadaic acid biotoxin. Colloids Surf B Biointerfaces 2015; 135:481-489. [PMID: 26283497 DOI: 10.1016/j.colsurfb.2015.07.077] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Revised: 07/04/2015] [Accepted: 07/28/2015] [Indexed: 10/23/2022]
Abstract
With the increasing movement away from the mouse bioassay for the detection of toxins in commercially harvested shellfish, there is a growing demand for the development of new and potentially field-deployable tests in its place. In this direction we report the development of a simple and sensitive nanoparticle-based luminescence technique for the detection of the marine biotoxin okadaic acid. Photoluminescent lanthanide nanoparticles were conjugated with fluorophore-labelled anti-okadaic acid antibodies which, upon binding to okadaic acid, gave rise to luminescence resonance energy transfer from the nanoparticle to the organic fluorophore dye deriving from a reduction in distance between the two. The intensity ratio of the fluorophore: nanoparticle emission peaks was found to correlate with okadaic acid concentration, and the sensor showed a linear response in the 0.37-3.97 μM okadaic acid range with a limit of detection of 0.25 μM. This work may have important implications for the development of new, cheap, and versatile biosensors for a range of biomolecules and that are sufficiently simple to be applied in the field or at point-of-care.
Collapse
Affiliation(s)
- Filip Stipić
- Center for Marine Research, Ruđer Bošković Institute, G. Paliaga 5, 52210 Rovinj, Croatia
| | - Petra Burić
- Center for Marine Research, Ruđer Bošković Institute, G. Paliaga 5, 52210 Rovinj, Croatia
| | - Željko Jakšić
- Center for Marine Research, Ruđer Bošković Institute, G. Paliaga 5, 52210 Rovinj, Croatia
| | - Galja Pletikapić
- Department of Marine and Environmental Research, Ruđer Bošković Institute, Bijenička cesta 54, 10000 Zagreb, Croatia
| | - Maja Dutour Sikirić
- Department of Physical Chemistry, Ruđer Bošković Institute, Bijenička cesta 54, 10000 Zagreb, Croatia
| | - Goran Zgrablić
- Time Resolved X-Ray Spectroscopy Laboratory, Elettra-Sincrotrone Trieste, 34149 Basovizza, Italy
| | - Leo Frkanec
- Department of Organic Chemistry and Biochemistry, Ruđer Bošković Institute, Bijenička cesta 54, 10000 Zagreb, Croatia
| | - Daniel M Lyons
- Center for Marine Research, Ruđer Bošković Institute, G. Paliaga 5, 52210 Rovinj, Croatia.
| |
Collapse
|
19
|
Le Berre M, Kilcoyne M, Kane M. Generation of a panel of high affinity antibodies and development of a biosensor-based immunoassay for the detection of okadaic acid in shellfish. Toxicon 2015; 103:169-75. [DOI: 10.1016/j.toxicon.2015.06.030] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2015] [Revised: 06/22/2015] [Accepted: 06/23/2015] [Indexed: 10/23/2022]
|
20
|
Eissa S, Ng A, Siaj M, Tavares AC, Zourob M. Selection and identification of DNA aptamers against okadaic acid for biosensing application. Anal Chem 2013; 85:11794-801. [PMID: 24164310 DOI: 10.1021/ac402220k] [Citation(s) in RCA: 101] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
This work describes the selection and identification of DNA aptamers that bind with high affinity and specificity to okadaic acid (OA), a lipophilic marine biotoxin that accumulates in shellfish. The aptamers selected using systematic evolution of ligands by exponential enrichment (SELEX) exhibited dissociation constants in the nanomolar range. The aptamer with the highest affinity was then used for the fabrication of a label-free electrochemical biosensor for okadaic acid detection. The aptamer was first immobilized on the gold electrode by a self-assembly approach through Au-S interaction. The binding of okadaic acid to the aptamer immobilized on the electrode surface induces an alteration of the aptamer conformation causing a significant decrease in the electron-transfer resistance monitored by electrochemical impedance spectroscopy. The aptasensor showed a linear range for the concentrations of OA between 100 pg/mL and 60 ng/mL with a detection limit of 70 pg/mL. The dissociation constant of okadaic acid with the aptamer immobilized on the electrode surface showed good agreement with that determined using fluorescence assay in solution. Moreover, the aptasensor did not show cross-reactivity toward toxins with structures similar to okadaic acid such as dinophysis toxin-1 and 2 (DTX-1, DTX-2). Further biosensing applications of the selected aptamers are expected to offer promising alternatives to the traditional analytical and immunological methods for OA detection.
Collapse
Affiliation(s)
- Shimaa Eissa
- Institut National de la Recherche Scientifique, Centre-Énergie, Matériaux et Télécommunications , 1650 Boulevard Lionel Boulet, Varennes, Québec J3X 1S2, Canada
| | | | | | | | | |
Collapse
|
21
|
Hayat A, Andreescu S. Nanoceria Particles As Catalytic Amplifiers for Alkaline Phosphatase Assays. Anal Chem 2013; 85:10028-32. [DOI: 10.1021/ac4020963] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- Akhtar Hayat
- Department of Chemistry and
Biomolecular Science, Clarkson University, Potsdam, NY 13699, United States
| | - Silvana Andreescu
- Department of Chemistry and
Biomolecular Science, Clarkson University, Potsdam, NY 13699, United States
| |
Collapse
|
22
|
Vilariño N, Louzao MC, Fraga M, Rodríguez LP, Botana LM. Innovative detection methods for aquatic algal toxins and their presence in the food chain. Anal Bioanal Chem 2013; 405:7719-32. [PMID: 23820950 DOI: 10.1007/s00216-013-7108-6] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2013] [Accepted: 05/31/2013] [Indexed: 01/17/2023]
Abstract
Detection of aquatic algal toxins has become critical for the protection of human health. During the last 5 years, techniques such as optical, electrochemical, and piezoelectric biosensors or fluorescent-microsphere-based assays have been developed for the detection of aquatic algal toxins, in addition to optimization of existing techniques, to achieve higher sensitivities, specificity, and speed or multidetection. New toxins have also been incorporated in the array of analytical and biological methods. The impact of the former innovation on this field is highlighted by recent changes in legal regulations, with liquid chromatography-mass spectrometry becoming the official reference method for marine lipophilic toxins and replacing the mouse bioassay in many countries. This review summarizes the large international effort to provide routine testing laboratories with fast, sensitive, high-throughput, multitoxin, validated methods for the screening of seafood, algae, and water samples.
Collapse
Affiliation(s)
- Natalia Vilariño
- Departamento de Farmacología, Facultad de Veterinaria, Universidad de Santiago de Compostela, 27002, Lugo, Spain,
| | | | | | | | | |
Collapse
|
23
|
Nourani S, Ghourchian H, Boutorabi SM. Magnetic nanoparticle-based immunosensor for electrochemical detection of hepatitis B surface antigen. Anal Biochem 2013; 441:1-7. [PMID: 23831477 DOI: 10.1016/j.ab.2013.06.011] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2013] [Revised: 06/18/2013] [Accepted: 06/22/2013] [Indexed: 12/11/2022]
Abstract
An electrochemical immunosensor was developed for the detection of hepatitis B surface antigen (HBsAg). The biotinylated hepatitis B surface antibody was immobilized on streptavidin magnetic nanoparticles and used for targeting the HBsAg. By the addition of horseradish peroxidase conjugated with secondary antibody (HRP-HBsAb), a sandwich-type immunoassay format was formed. Aminophenol as substrate for conjugated HRP was enzymatically changed into 3-aminophenoxazone (3-APZ). This electroactive enzymatic production (3-APZ) was transferred into an electrochemical cell and monitored by cyclic voltammetry. Under optimal conditions, the cathodic current response of 3-APZ, which was proportional to the HBsAg concentration, was measured by a glassy carbon electrode. The immunosensor response was linear toward HBsAg in the concentration range from 0.001 to 0.015 ng/ml with a detection limit of 0.9 pg/ml at a signal/noise ratio of 3.
Collapse
Affiliation(s)
- Sara Nourani
- Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, Tehran, Iran
| | | | | |
Collapse
|
24
|
Automated, high performance, flow-through chemiluminescence microarray for the multiplexed detection of phycotoxins. Anal Chim Acta 2013; 787:211-8. [DOI: 10.1016/j.aca.2013.05.028] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2012] [Revised: 05/10/2013] [Accepted: 05/14/2013] [Indexed: 02/05/2023]
|
25
|
Improvement of the efficiency and simplification of ELISA tests for rapid and ultrasensitive detection of okadaic acid in shellfish. Food Control 2013. [DOI: 10.1016/j.foodcont.2012.05.028] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
26
|
Sassolas A, Hayat A, Catanante G, Marty JL. Detection of the marine toxin okadaic acid: Assessing seafood safety. Talanta 2013; 105:306-16. [DOI: 10.1016/j.talanta.2012.10.049] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2012] [Revised: 10/10/2012] [Accepted: 10/13/2012] [Indexed: 10/27/2022]
|
27
|
Eissa S, Zourob M. A graphene-based electrochemical competitive immunosensor for the sensitive detection of okadaic acid in shellfish. NANOSCALE 2012; 4:7593-7599. [PMID: 23108911 DOI: 10.1039/c2nr32146g] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A novel graphene-based voltammetric immunosensor for sensitive detection of okadaic acid (OA) was developed. A simple and efficient electrografting method was utilized to functionalize graphene-modified screen-printed carbon electrodes (GSPE) by the electrochemical reduction of in situ generated 4-carboxyphenyl diazonium salt in acidic aqueous solution. Next, the okadaic acid antibody was covalently immobilized on the carboxyphenyl modified graphene electrodes via carbodiimide chemistry. Square wave voltammetry (SWV) was used to investigate the stepwise assembly of the immunosensor. A competitive assay between OA and a fixed concentration of okadaic acid-ovalbumin conjugate (OA-OVA) for the immobilized antibodies was employed for the detection of okadaic acid. The decrease of the [Fe(CN)(6)](3-/4-) reduction peak current in the square wave voltammetry for various concentrations of okadaic acid was used for establishing the calibration curve. A linear relationship between the SWV peak current difference and OA concentration was obtained up to ~5000 ng L(-1). The developed immunosensor allowed a detection limit of 19 ng L(-1) of OA in PBS buffer. The matrix effect studied with spiked shellfish tissue extracts showed a good percentage of recovery and the method was also validated with certified reference mussel samples.
Collapse
Affiliation(s)
- Shimaa Eissa
- Institut national de la recherche scientifique, Centre - Energie, Matériaux et Télécommunications, 1650, Boul. Lionel Boulet, Varennes, Québec J3X 1S2, Canada
| | | |
Collapse
|
28
|
Rochelet M, Solanas S, Grossiord C, Maréchal P, Résa C, Vienney F, Barranger C, Joannes M. A thin layer-based amperometric enzyme immunoassay for the rapid and sensitive diagnosis of respiratory syncytial virus infections. Talanta 2012; 100:139-44. [PMID: 23141321 DOI: 10.1016/j.talanta.2012.07.088] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2012] [Revised: 07/28/2012] [Accepted: 07/31/2012] [Indexed: 11/17/2022]
Abstract
A simple electrochemical sandwich immunoassay involving a polystyrene microarray slide coated with monoclonal capture antibodies and carbon screen-printed sensors (SPS) was designed for the rapid diagnosis of respiratory syncytial virus (RSV). The detection of the antibody-antigen complex formation relied on the use of a horseradish peroxidase conjugate. Its chronoamperometric measurement detection was performed by confining a droplet of H(2)O(2)/3,3',5,5'-tetramethylbenzidine enzyme substrate/mediator solution within a thin layer between one spot of the microarray and the surface of one screen-printed electrochemical cell. The accumulation of the enzyme product in the thin film of liquid enhanced the electrochemical response which allowed the development of a rapid (25 min) and sensitive thin layer-based amperometric (TLA) enzyme immunoassay. The method was successfully compared to commercially-available immunofluorescent and real-time PCR assays for RSV testing in respiratory secretion clinical samples. This suggests that owing to its rapidity, convenience, low-cost, portability and ability to provide quantified results, the reported concept could be a promising point-of-care diagnostic tool to screen patients with suspected respiratory infection or other types of infectious diseases.
Collapse
Affiliation(s)
- Murielle Rochelet
- Université de Bourgogne, UMR 1347 Agroécologie, 7 Boulevard Jeanne d'Arc, 21000 Dijon, France.
| | | | | | | | | | | | | | | |
Collapse
|
29
|
Automated flow-through amperometric immunosensor for highly sensitive and on-line detection of okadaic acid in mussel sample. Talanta 2012; 99:232-7. [PMID: 22967546 DOI: 10.1016/j.talanta.2012.05.045] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2012] [Revised: 05/11/2012] [Accepted: 05/19/2012] [Indexed: 12/30/2022]
Abstract
An electrochemical immunosensor for okadaic acid (OA) detection has been developed, and used in an indirect competitive immunoassay format under automated flow conditions. The biosensor was fabricated by injecting OA modified magnetic beads onto screen printed carbon electrode (SPCE) in the flow system. The OA present in the sample competed with the immobilized OA to bind with anti-okadaic acid monoclonal antibody (anti-OA-MAb). The secondary alkaline phosphatase labeled antibody was used to perform electrochemical detection. The current response obtained from the labeled alkaline phosphatase to 1-naphthyl phosphate decreased proportionally to the concentration of free OA in the sample. The calculated limit of detection (LOD) was 0.15 μg/L with a linear range of 0.19-25 μg/L. The good recoveries percentages validated the immunosensor application for real mussel samples. The developed system automatically controlled the incubation, washing and current measurement steps, showing its potential use for OA determination in field analysis.
Collapse
|
30
|
Hayat A, Barthelmebs L, Sassolas A, Marty JL. Development of a novel label-free amperometric immunosensor for the detection of okadaic acid. Anal Chim Acta 2012; 724:92-7. [PMID: 22483215 DOI: 10.1016/j.aca.2012.02.035] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2011] [Revised: 02/13/2012] [Accepted: 02/18/2012] [Indexed: 10/28/2022]
Abstract
Okadaic acid (OA), a lipophilic phycotoxin is mainly produced by toxigenic dinoflagellates. The need to develop high performing methods for OA analysis able to improve the traditional ones is evident. In this work, a novel experimental methodology for label-free detection of OA was developed. Protein G magnetic beads (protein-G-MBs) modified gold electrode was used to immobilize anti-OA monoclonal antibody (anti-OA-MAb). Preliminary, colorimetric tests were performed in order to validate protein-G-MBs and anti-OA-MAb reaction. Electrochemical detection was carried out by differential pulse voltammetry in ferri/ferrocyanide solution. The limit of detection value obtained (0.5 μg L(-1)) validated the developed electrochemical immunosensor as a promising tool for routine use. The matrix effect and the recovery rate were also assessed with real samples, showing a good percentage of recovery.
Collapse
Affiliation(s)
- Akhtar Hayat
- Université Perpignan Via Domitia, Institut de Modélisation et d'Analyse en Géo-Environnement et Santé, Perpignan, France
| | | | | | | |
Collapse
|
31
|
WANG QUAN, LIU YINGCHUN, LI JIAN, JIANG WEI, CHEN YONGJUN, SONG NINGNING. DEVELOPMENT OF A CHEMILUMINESCENT ELISA FOR DETERMINING OKADAIC ACID IN SHELLFISH. J FOOD QUALITY 2012. [DOI: 10.1111/j.1745-4557.2011.00423.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
32
|
Campàs M, Garibo D, Prieto-Simón B. Novel nanobiotechnological concepts in electrochemical biosensors for the analysis of toxins. Analyst 2012; 137:1055-67. [DOI: 10.1039/c2an15736e] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
33
|
Garibo D, Devic E, Marty JL, Diogène J, Unzueta I, Blázquez M, Campàs M. Conjugation of genetically engineered protein phosphatases to magnetic particles for okadaic acid detection. J Biotechnol 2012; 157:89-95. [DOI: 10.1016/j.jbiotec.2011.11.020] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2011] [Revised: 11/14/2011] [Accepted: 11/22/2011] [Indexed: 10/14/2022]
|
34
|
Gold nanolabels and enzymatic recycling dual amplification-based electrochemical immunosensor for the highly sensitive detection of carcinoembryonic antigen. Sci China Chem 2011. [DOI: 10.1007/s11426-011-4373-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
35
|
Hayat A, Barthelmebs L, Sassolas A, Marty JL. An electrochemical immunosensor based on covalent immobilization of okadaic acid onto screen printed carbon electrode via diazotization-coupling reaction. Talanta 2011; 85:513-8. [DOI: 10.1016/j.talanta.2011.04.034] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2011] [Revised: 03/30/2011] [Accepted: 04/11/2011] [Indexed: 11/25/2022]
|
36
|
Chunglok W, Khownarumit P, Rijiravanich P, Somasundrum M, Surareungchai W. Electrochemical immunoassay platform for high sensitivity protein detection based on redox-modified carbon nanotube labels. Analyst 2011; 136:2969-74. [PMID: 21647503 DOI: 10.1039/c1an15079k] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
We report a highly sensitive immunoassay protocol based on the use of redox-modified multi-walled carbon nanotubes (MWNTs) as electrochemical labels. The MWNTs were coated with methylene blue (MB) at an optically-determined loading of 3.41 × 10(-3) mol g(-1), and were then attached to secondary antibodies (Ab(2)) by adsorption. As a model analyte mouse IgG was collected by primary antibody (Ab(1))-coated magnetic beads. Following binding of the MB-MWNT-Ab(2) conjugates, IgG could be measured by MB reduction. Using differential pulse voltammetry for quantification, IgG was calibrated with a dynamic range of 0.1 pg mL(-1) to 100 pg mL(-1). Given the different possible Ab(1)-MB-MWNT-Ab(2) orientations on the magnetic beads, it was likely that not all the MB communicated with the electrode. A greater quantity of MB could be accessed by using the Fe(CN)(6)(3-/4-) redox couple as a solution phase mediator. This enabled us to lower the dynamic range down to 5 fg mL(-1) to 100 fg mL(-1).
Collapse
Affiliation(s)
- Wilanee Chunglok
- School of Bioresources and Technology, King Mongkut's University of Technology Thonburi, Bangkhuntien Campus, Bangkok, 10150, Thailand
| | | | | | | | | |
Collapse
|
37
|
Hayat A, Barthelmebs L, Marty JL. Enzyme-linked immunosensor based on super paramagnetic nanobeads for easy and rapid detection of okadaic acid. Anal Chim Acta 2011; 690:248-52. [DOI: 10.1016/j.aca.2011.02.031] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2010] [Revised: 02/04/2011] [Accepted: 02/12/2011] [Indexed: 10/18/2022]
|
38
|
Abstract
In this review, the current status of research in electrochemical immunosensors is considered. We primarily focus on label-free and enzyme-labeled immunosensors, and the analytical capabilities of these devices are discussed. Moreover, the use of magnetic beads as new materials for immunosensors coupled with electrochemical sensing is also described, together with the application of new molecules such as aptamers as specific biorecognition elements. Examples of the applicability of these devices in solving various analytical problems in clinical, environmental and food fields are reported. Finally, the prospects for the further development of immunosensor technologies are shown.
Collapse
|
39
|
Liu Q, Han M, Bao J, Jiang X, Dai Z. CdSe quantum dots as labels for sensitive immunoassay of cancer biomarker proteins by electrogenerated chemiluminescence. Analyst 2011; 136:5197-203. [DOI: 10.1039/c1an15581d] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
40
|
An electrochemical enzyme bioaffinity electrode based on biotin–streptavidin conjunction and bienzyme substrate recycling for amplification. Anal Biochem 2010; 405:121-6. [DOI: 10.1016/j.ab.2010.05.025] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2010] [Revised: 05/19/2010] [Accepted: 05/21/2010] [Indexed: 11/18/2022]
|
41
|
Biological methods for marine toxin detection. Anal Bioanal Chem 2010; 397:1673-81. [PMID: 20458470 DOI: 10.1007/s00216-010-3782-9] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2010] [Revised: 04/13/2010] [Accepted: 04/23/2010] [Indexed: 10/19/2022]
Abstract
The presence of marine toxins in seafood poses a health risk to human consumers which has prompted the regulation of the maximum content of marine toxins in seafood in the legislations of many countries. Most marine toxin groups are detected by animal bioassays worldwide. Although this method has well known ethical and technical drawbacks, it is the official detection method for all regulated phycotoxins except domoic acid. Much effort by the scientific and regulatory communities has been focused on the development of alternative techniques that enable the substitution or reduction of bioassays; some of these have recently been included in the official detection method list. During the last two decades several biological methods including use of biosensors have been adapted for detection of marine toxins. The main advances in marine toxin detection using this kind of technique are reviewed. Biological methods offer interesting possibilities for reduction of the number of biosassays and a very promising future of new developments.
Collapse
|
42
|
Gerssen A, Pol-Hofstad IE, Poelman M, Mulder PP, van den Top HJ, de Boer J. Marine toxins: chemistry, toxicity, occurrence and detection, with special reference to the Dutch situation. Toxins (Basel) 2010; 2:878-904. [PMID: 22069615 PMCID: PMC3153220 DOI: 10.3390/toxins2040878] [Citation(s) in RCA: 83] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2010] [Revised: 04/14/2010] [Accepted: 04/22/2010] [Indexed: 11/29/2022] Open
Abstract
Various species of algae can produce marine toxins under certain circumstances. These toxins can then accumulate in shellfish such as mussels, oysters and scallops. When these contaminated shellfish species are consumed severe intoxication can occur. The different types of syndromes that can occur after consumption of contaminated shellfish, the corresponding toxins and relevant legislation are discussed in this review. Amnesic Shellfish Poisoning (ASP), Paralytic Shellfish Poisoning (PSP), Diarrheic Shellfish Poisoning (DSP) and Azaspiracid Shellfish Poisoning (AZP) occur worldwide, Neurologic Shellfish Poisoning (NSP) is mainly limited to the USA and New Zealand while the toxins causing DSP and AZP occur most frequently in Europe. The latter two toxin groups are fat-soluble and can therefore also be classified as lipophilic marine toxins. A detailed overview of the official analytical methods used in the EU (mouse or rat bioassay) and the recently developed alternative methods for the lipophilic marine toxins is given. These alternative methods are based on functional assays, biochemical assays and chemical methods. From the literature it is clear that chemical methods offer the best potential to replace the animal tests that are still legislated worldwide. Finally, an overview is given of the situation of marine toxins in The Netherlands. The rat bioassay has been used for monitoring DSP and AZP toxins in The Netherlands since the 1970s. Nowadays, a combination of a chemical method and the rat bioassay is often used. In The Netherlands toxic events are mainly caused by DSP toxins, which have been found in Dutch shellfish for the first time in 1961, and have reoccurred at irregular intervals and in varying concentrations. From this review it is clear that considerable effort is being undertaken by various research groups to phase out the animal tests that are still used for the official routine monitoring programs.
Collapse
Affiliation(s)
- Arjen Gerssen
- RIKILT, Institute of Food Safety, Wageningen UR, Akkermaalsbos 2, 6708 WB Wageningen, The Netherlands; (P.P.J.M.); (H.J.T.)
- Author to whom correspondence should be addressed; ; Tel.: +0031-317-480433; Fax: 0031-317-417717
| | - Irene E. Pol-Hofstad
- Microbiological Laboratory for Health Protection, National Institute for Public Health and the Environment, A. van Leeuwenhoeklaan 9, 3720 BA Bilthoven, The Netherlands;
| | - Marnix Poelman
- IMARES, Wageningen UR, Korringaweg 5, 4401 NT Yerseke, The Netherlands;
| | - Patrick P.J. Mulder
- RIKILT, Institute of Food Safety, Wageningen UR, Akkermaalsbos 2, 6708 WB Wageningen, The Netherlands; (P.P.J.M.); (H.J.T.)
| | - Hester J. van den Top
- RIKILT, Institute of Food Safety, Wageningen UR, Akkermaalsbos 2, 6708 WB Wageningen, The Netherlands; (P.P.J.M.); (H.J.T.)
| | - Jacob de Boer
- Institute for Environmental Studies, VU University, De Boelelaan 1087, 1081 HV Amsterdam, The Netherlands;
| |
Collapse
|
43
|
Use of biosensors as alternatives to current regulatory methods for marine biotoxins. SENSORS 2009; 9:9414-43. [PMID: 22291571 PMCID: PMC3260648 DOI: 10.3390/s91109414] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2009] [Revised: 10/27/2009] [Accepted: 10/28/2009] [Indexed: 12/12/2022]
Abstract
Marine toxins are currently monitored by means of a bioassay that requires the use of many mice, which poses a technical and ethical problem in many countries. With the exception of domoic acid, there is a legal requirement for the presence of other toxins (yessotoxin, saxitoxin and analogs, okadaic acid and analogs, pectenotoxins and azaspiracids) in seafood to be controlled by bioassay, but other toxins, such as palytoxin, cyclic imines, ciguatera and tetrodotoxin are potentially present in European food and there are no legal requirements or technical approaches available to identify their presence. The need for alternative methods to the bioassay is clearly important, and biosensors have become in recent years a feasible alternative to animal sacrifice. This review will discuss the advantages and disadvantages of using biosensors as alternatives to animal assays for marine toxins, with particular focus on surface plasmon resonance (SPR) technology.
Collapse
|
44
|
Prieto-Simón B, Miyachi H, Karube I, Saiki H. High-sensitive flow-based kinetic exclusion assay for okadaic acid assessment in shellfish samples. Biosens Bioelectron 2009; 25:1395-401. [PMID: 19939663 DOI: 10.1016/j.bios.2009.10.039] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2009] [Revised: 10/23/2009] [Accepted: 10/23/2009] [Indexed: 11/16/2022]
Abstract
Episodes of shellfish contamination with okadaic acid (OA) are a human health threat that is causing increasing concern. As a way to overcome the shortcomings involved in the reference methods of analysis set by legislations, alternative procedures are envisaged. This paper describes the development of different immunosensors for the analysis of OA, focusing on the comparison of their sensitivity, precision, ease of use and sample matrix effects. Initially, a surface plasmon resonance (SPR)-based immunosensor was developed, which enabled the quantification of the toxin in mussel samples at concentrations in the range of the 160 microg kg(-1) European regulatory limit with good percentages of recovery. Nevertheless, calibration curves with spiked mussel samples showed that matrix effects could not be neglected. Alternatively, a flow-immunosensing system based on kinetic exclusion measurements was developed achieving the theoretical lowest limit of detection enabled by the affinity of the anti-OA antibody (IC(70)=0.03 microg L(-1) in the assay solution). This highly sensitive automated system allows rapid and reliable OA quantification, with no significant matrix effects for the analysis of spiked mussel and scallop samples. Performance features such as high sensitivity and precision, low limits of detection and simplicity of the analysis protocol, shows the biosensing-systems based on kinetic exclusion measurements for toxin detection in shellfish samples as highly performing tools for rapid and continuous screening.
Collapse
Affiliation(s)
- Beatriz Prieto-Simón
- School of Bioscience and Biotechnology, Tokyo University of Technology, Katayanagi Institute, Tokyo, Japan.
| | | | | | | |
Collapse
|
45
|
Antibody-based sensors: principles, problems and potential for detection of pathogens and associated toxins. SENSORS 2009; 9:4407-45. [PMID: 22408533 PMCID: PMC3291918 DOI: 10.3390/s90604407] [Citation(s) in RCA: 190] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2009] [Revised: 05/26/2009] [Accepted: 05/26/2009] [Indexed: 01/30/2023]
Abstract
Antibody-based sensors permit the rapid and sensitive analysis of a range of pathogens and associated toxins. A critical assessment of the implementation of such formats is provided, with reference to their principles, problems and potential for 'on-site' analysis. Particular emphasis is placed on the detection of foodborne bacterial pathogens, such as Escherichia coli and Listeria monocytogenes, and additional examples relating to the monitoring of fungal pathogens, viruses, mycotoxins, marine toxins and parasites are also provided.
Collapse
|
46
|
Bojorge Ramírez N, Salgado AM, Valdman B. The evolution and developments of immunosensors for health and environmental monitoring: problems and perspectives. BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING 2009. [DOI: 10.1590/s0104-66322009000200001] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Affiliation(s)
| | | | - B. Valdman
- Universidade Federal de Rio de Janeiro, Brasil
| |
Collapse
|
47
|
Tang D, Niessner R, Knopp D. Flow-injection electrochemical immunosensor for the detection of human IgG based on glucose oxidase-derivated biomimetic interface. Biosens Bioelectron 2008; 24:2125-30. [PMID: 19109003 DOI: 10.1016/j.bios.2008.11.008] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2008] [Revised: 10/24/2008] [Accepted: 11/07/2008] [Indexed: 11/25/2022]
Abstract
A newly flow-through electrochemical immunosensor for monitoring IgG in human serum has been developed by using core-shell SiO(2)/Au nanocomposites and poly(amidoamine) G4 dendrimer as matrices. The ferrocenecarboaldehyde-labeled anti-IgG biomolecules were initially chemisorbed onto the nanoparticle surface, and then glucose oxidase (GOx), as a blocking reagent instead of bovine serum albumin (BSA), was backfilled onto the modified surface. The formation of the antibody-antigen complex by a simple one-step immunoreaction between the immobilized anti-IgG and IgG in sample solution introduced a barrier of direct electrical communication between the immobilized GOx and the base surface, and decreased the immobilized GOx toward the catalytic oxidation of glucose. The performance and factors influencing the performance of the immunosensor were evaluated. Under optimal conditions, the linear range of the developed immunosensor by using GOx as enhancer was from 5.0 x 10(-6) to 9.6 x 10(-4)mol/L with a detection limit of 8.0 x 10(-7)mol/L IgG (at 3delta), while the detection limit by using BSA was 1.5 x 10(-5)mol/L IgG (at 3delta) with the linear range from 3.5 x 10(-5) to 1.2 x 10(-3)mol/L. The selectivity, reproducibility and stability of the proposed immunosensor were acceptable. The IgG contents in 37 human serum samples obtained by the proposed method are identical with the data of clinical laboratory.
Collapse
Affiliation(s)
- Dianping Tang
- Chair for Analytical Chemistry, Institute of Hydrochemistry, Technische Universität München, Marchioninistrasse 17, D-81377 München, Germany
| | | | | |
Collapse
|