1
|
Hu Y, Dai X, Zhang H, Dai Q, Niu B, Jing G, Li Y, Fan G. Observing multi-frequency structured illumination patterns based on an evanescent field in a millimeter-scale polymer slide. OPTICS LETTERS 2024; 49:4903-4906. [PMID: 39207993 DOI: 10.1364/ol.532009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Accepted: 08/07/2024] [Indexed: 09/04/2024]
Abstract
Millimeter-scale slide optical waveguides (OWGs) show the potential to break the barrier of easy-to-use and versatility for total internal reflection (TIR) fluorescence technology. In this paper, multi-frequency structured illumination (SI) patterns resulting from the evanescent field (EF) on the surface of a millimeter-scale polymer slide OWG are observed by measuring the fluorescence intensity distribution of fluorescent dyes deposited on the top of the OWG. The frequency, intensity, and stability of the SI patterns show a strong dependence on the coupling angle of the incident light (changing with the incident position). The distribution of multi-frequency SI patterns in the frequency space is demonstrated for different numerical aperture (NA) imaging systems (NA = 0.3, 0.6, and 0.8), indicating the potential for enhanced resolution for low NA systems with a simple and cheap polymer slide.
Collapse
|
2
|
A Highly Integrated and Diminutive Fluorescence Detector for Point-of-Care Testing: Dual Negative Feedback Light-Emitting Diode (LED) Drive and Photoelectric Processing Circuits Design and Implementation. BIOSENSORS 2022; 12:bios12090764. [PMID: 36140149 PMCID: PMC9496958 DOI: 10.3390/bios12090764] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 09/08/2022] [Accepted: 09/14/2022] [Indexed: 11/17/2022]
Abstract
As an important detection tool in biochemistry, fluorescence detection has wide applications. Quantitative detection can be achieved by detecting fluorescence signals excited by excitation light at a specific wavelength range. Therefore, the key to fluorescence detection is the stable control of the excitation light and the accurate acquisition of weak photoelectric signals. Moreover, to improve portability and instantaneity, devices are developing in miniaturization and integration. As the core of such devices, fluorescence detectors should also have these features. Under this circumstance, we designed a highly integrated and diminutive fluorescence detector and focused on its excitation light driving and photoelectric signal processing. A current–light dual negative feedback light-emitting diode (LED) driving circuit was proposed to obtain constant current and luminance. In addition, a silicon photodiode (PD) was used to receive and convert the fluorescence signal to an electric signal. Then, amplifying, filtering, and analog-to-digital (A/D) converting were applied to make the detection of weak fluorescence signals possible. The test results showed that the designed circuit has wonderful performance, and the detector shows good linearity (R2 = 0.9967) and sensitivity (LOD = 0.077 nM) in the detection of fluorescein sodium solution. Finally, a real-time fluorescence polymerase chain reaction (real-time PCR) of Legionella pneumophila was carried out on a homemade platform equipped with this detector, indicating that the detector met the requirements of real-time PCR detection.
Collapse
|
3
|
Jeon HJ, Kim HS, Chung E, Lee DY. Nanozyme-based colorimetric biosensor with a systemic quantification algorithm for noninvasive glucose monitoring. Theranostics 2022; 12:6308-6338. [PMID: 36168630 PMCID: PMC9475463 DOI: 10.7150/thno.72152] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 08/20/2022] [Indexed: 11/10/2022] Open
Abstract
Diabetes mellitus accompanies an abnormally high glucose level in the bloodstream. Early diagnosis and proper glycemic management of blood glucose are essential to prevent further progression and complications. Biosensor-based colorimetric detection has progressed and shown potential in portable and inexpensive daily assessment of glucose levels because of its simplicity, low-cost, and convenient operation without sophisticated instrumentation. Colorimetric glucose biosensors commonly use natural enzymes that recognize glucose and chromophores that detect enzymatic reaction products. However, many natural enzymes have inherent defects, limiting their extensive application. Recently, nanozyme-based colorimetric detection has drawn attention due to its merits including high sensitivity, stability under strict reaction conditions, flexible structural design with low-cost materials, and adjustable catalytic activities. This review discusses various nanozyme materials, colorimetric analytic methods and mechanisms, recent machine learning based analytic methods, quantification systems, applications and future directions for monitoring and managing diabetes.
Collapse
Affiliation(s)
- Hee-Jae Jeon
- Weldon School of Biomedical Engineering, Purdue University, Indiana 47906, USA
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon 24341, Republic of Korea
| | - Hyung Shik Kim
- Department of Bioengineering, College of Engineering, and BK FOUR Biopharmaceutical Innovation Leader for Education and Research Group, Hanyang University, Seoul 04763, Republic of Korea
| | - Euiheon Chung
- Department of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea
- AI Graduate School, GIST, Gwangju 61005, Republic of Korea
- Research Center for Photon Science Technology, GIST, Gwangju 61005, Republic of Korea
| | - Dong Yun Lee
- Department of Bioengineering, College of Engineering, and BK FOUR Biopharmaceutical Innovation Leader for Education and Research Group, Hanyang University, Seoul 04763, Republic of Korea
- Institute of Nano Science and Technology (INST), Hanyang University, Seoul 04763, Republic of Korea
- Institute for Bioengineering and Biopharmaceutical Research (IBBR), Hanyang University, Seoul 04763, Republic of Korea
- Elixir Pharmatech Inc., Seoul 07463, Republic of Korea
| |
Collapse
|
4
|
Guan T, Xu Z, Wang J, Liu Y, Shen X, Li X, Sun Y, Lei H. Multiplex optical bioassays for food safety analysis: Toward on-site detection. Compr Rev Food Sci Food Saf 2022; 21:1627-1656. [PMID: 35181985 DOI: 10.1111/1541-4337.12914] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 12/28/2021] [Accepted: 12/29/2021] [Indexed: 12/15/2022]
Abstract
Food safety analysis plays a significant role in controlling food contamination and supervision. In recent years, multiplex optical bioassays (MOBAs) have been widely applied to analyze multiple hazards due to their efficiency and low cost. However, due to the challenges such as multiplexing capacity, poor sensitivity, and bulky instrumentation, the further application of traditional MOBAs in food screening has been limited. In this review, effective strategies regarding food safety MOBAs are summarized, such as spatial-resolution modes performed in multi-T lines/dots strips or arrays of strip/microplate/microfluidic chip/SPR chip and signal-resolution modes employing distinguishable colorimetric/luminescence/fluorescence/surface plasma resonance/surface-enhanced Raman spectrum as signal tags. Following this, new trends on how to design engineered sensor architecture and exploit distinguishable signal reporters, how to improve both multiplexing capacity and sensitivity, and how to integrate these formats into smartphones so as to be mobile are summarized systematically. Typically, in the case of enhancing multiplexing capacity and detection throughput, microfluidic array chips with multichannel architecture would be a favorable approach to overcome the spatial and physical limitations of immunochromatographic assay (ICA) test strips. Moreover, noble metal nanoparticles and single-excitation, multiple-emission luminescence nanomaterials hold great potential in developing ultrasensitive MOBAs. Finally, the exploitation of innovative multiplexing strategy hybridized with powerful and widely available smartphones opens new perspectives to MOBAs. In future, the MOBAs should be more sensitive, have higher multiplexing capacity, and easier instrumentation.
Collapse
Affiliation(s)
- Tian Guan
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China
| | - Zhenlin Xu
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China.,Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
| | - Jin Wang
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China
| | - Yingju Liu
- Department of Applied Chemistry, College of Materials and Energy, South China Agricultural University, Guangzhou, China
| | - Xing Shen
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China
| | - Xiangmei Li
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China
| | - Yuanming Sun
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China
| | - Hongtao Lei
- Guangdong Provincial Key Laboratory of Food Quality and Safety / Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China.,Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
| |
Collapse
|
5
|
Murray LP, Mace CR. Usability as a guiding principle for the design of paper-based, point-of-care devices - A review. Anal Chim Acta 2020; 1140:236-249. [PMID: 33218486 DOI: 10.1016/j.aca.2020.09.063] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Revised: 09/28/2020] [Accepted: 09/30/2020] [Indexed: 12/14/2022]
Abstract
Due to their portability, versatility for supporting multiple assay formats, and potential for resulting in low-cost assays, paper-based analytical devices (PADs) are an increasingly popular format as a platform for the development of point-of-care tests. However, very few PADs have been translated successfully to their intended environments outside of academic settings. Often overlooked as a factor that inhibits translation, usability is a vital characteristic of any successful point-of-care test. Recent advancements in PAD design have demonstrated improved usability by simplifying various aspects of user operation, including sample collection, sample processing, device operation, detection, and readout/interpretation. Field testing at various stages of device design can offer critical feedback about device usability, especially when it involves the proposed end-user or other stakeholders. By highlighting advances in usability, we aim to encourage thoughtful and rigorous design at the academic prototyping stage to address one outstanding hurdle that limits the number of PADs that make it from the benchtop to the point-of-care.
Collapse
Affiliation(s)
- Lara P Murray
- Department of Chemistry, Tufts University, Medford, MA, 02155, USA
| | - Charles R Mace
- Department of Chemistry, Tufts University, Medford, MA, 02155, USA.
| |
Collapse
|
6
|
Yang J, Wang K, Xu H, Yan W, Jin Q, Cui D. Detection platforms for point-of-care testing based on colorimetric, luminescent and magnetic assays: A review. Talanta 2019; 202:96-110. [PMID: 31171232 DOI: 10.1016/j.talanta.2019.04.054] [Citation(s) in RCA: 93] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 04/03/2019] [Accepted: 04/20/2019] [Indexed: 12/14/2022]
Abstract
Along with the considerable potential and increasing demand of the point-of-care testing (POCT), corresponding detection platforms have attracted great interest in both academic and practical fields. The first few generations of conventional detection devices tend to be costly, complicated to operate and hard to move on account of early limitations in the level of technological development and relatively high requirement of performance. Owing to the requirements for rapidity, simplicity, accuracy and cost controlling in the POCT, reader systems are urgently needed to be developed, upgraded and modified constantly, realizing on-site testing and healthcare management without a specific place or cumbersome operation. Accordingly, numerous rapid detection platforms with diverse size and performance have emerged such as bench-top apparatuses, handheld devices and intelligent detection devices. This review discusses various devices developed mainly for the detection of lateral flow test strips (LFTSs) or microfluidic strips in the POCT and summarizes these devices by size and portability. Furthermore, on the basis of various detection methods and diverse probes usually containing specific nanoparticles composites, three most common aspects of detection rationale in the POCT are selected to elaborate each kind of detection platforms in this paper: colorimetric assay, luminescent detection and magnetic signal detection. Herein, we focus on their structures, detection mechanisms and assay results, accompany with discussions and comments on the performances, costs and potential application, as well as advantages and limitations of each technique. In addition, perspectives on the future advances of detection platforms and some conclusions are proposed.
Collapse
Affiliation(s)
- Jinchuan Yang
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Key Laboratory of Thin Film and Microfabrication (Ministry of Education), Shanghai, 200240, PR China.
| | - Kan Wang
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Key Laboratory of Thin Film and Microfabrication (Ministry of Education), Shanghai, 200240, PR China.
| | - Hao Xu
- School of Naval Architecture, Ocean & Civil Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China.
| | - Wenqiang Yan
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Key Laboratory of Thin Film and Microfabrication (Ministry of Education), Shanghai, 200240, PR China.
| | - Qinghui Jin
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, PR China; Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, 315211, PR China.
| | - Daxiang Cui
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Key Laboratory of Thin Film and Microfabrication (Ministry of Education), Shanghai, 200240, PR China.
| |
Collapse
|
7
|
Sauer U. Analytical Protein Microarrays: Advancements Towards Clinical Applications. SENSORS (BASEL, SWITZERLAND) 2017; 17:E256. [PMID: 28146048 PMCID: PMC5335935 DOI: 10.3390/s17020256] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2016] [Revised: 01/13/2017] [Accepted: 01/23/2017] [Indexed: 01/28/2023]
Abstract
Protein microarrays represent a powerful technology with the potential to serve as tools for the detection of a broad range of analytes in numerous applications such as diagnostics, drug development, food safety, and environmental monitoring. Key features of analytical protein microarrays include high throughput and relatively low costs due to minimal reagent consumption, multiplexing, fast kinetics and hence measurements, and the possibility of functional integration. So far, especially fundamental studies in molecular and cell biology have been conducted using protein microarrays, while the potential for clinical, notably point-of-care applications is not yet fully utilized. The question arises what features have to be implemented and what improvements have to be made in order to fully exploit the technology. In the past we have identified various obstacles that have to be overcome in order to promote protein microarray technology in the diagnostic field. Issues that need significant improvement to make the technology more attractive for the diagnostic market are for instance: too low sensitivity and deficiency in reproducibility, inadequate analysis time, lack of high-quality antibodies and validated reagents, lack of automation and portable instruments, and cost of instruments necessary for chip production and read-out. The scope of the paper at hand is to review approaches to solve these problems.
Collapse
Affiliation(s)
- Ursula Sauer
- AIT Austrian Institute of Technology GmbH, Center for Health and Bioresources, 3430 Tulln, Austria.
| |
Collapse
|
8
|
Badugu R, Mao J, Blair S, Zhang D, Descrovi E, Angelini A, Huo Y, Lakowicz JR. Bloch Surface Wave-Coupled Emission at Ultra-Violet Wavelengths. THE JOURNAL OF PHYSICAL CHEMISTRY. C, NANOMATERIALS AND INTERFACES 2016; 120:28727-28734. [PMID: 28725334 PMCID: PMC5512112 DOI: 10.1021/acs.jpcc.6b08086] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
The interaction of fluorophores with nearby metallic structures is now an active area of research. Dielectric photonic structures offer some advantages over plasmonic structures, namely small energy losses and less quenching. We describe a dielectric one-dimensional photonic crystal (1DPC), which supports Bloch surface waves (BSWs) from 280 to 440 nm. This BSW structure is a quartz slide coated with alternating layers of SiO2 and Si3N4. We show that this structure displays BSWs and that the near-UV fluorophore, 2-aminopurine (2-AP), on the top surface of the structure couples with the BSWs. Fluorophores do not have to be inside the structure for coupling and show a narrow angular distribution, with an angular separation of wavelengths. The Bloch wave-coupled emission (BWCE) radiates through the dielectric layer. These BSW structures, with useful wavelength range for detection of intrinsic protein and cofactor fluorescence, provide opportunities for novel optical configurations for bioassays with surface-localized biomolecules and for optical imaging using the coupled emission.
Collapse
Affiliation(s)
- Ramachandram Badugu
- Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology, University of Maryland School of Medicine, 725 West Lombard Street, Baltimore, MD 21201, USA
| | - Jieying Mao
- Department of Physics and Astronomy, University of Utah, 50 S. Central Campus Drive, Salt Lake City, UT 84112, USA
| | - Steve Blair
- Department of Electrical and Computer Engineering, University of Utah, 50 S. Central Campus Drive, Salt Lake City, UT 84112, USA
| | - Douguo Zhang
- Institute of Photonics, Department of Optics and Optical Engineering, University of Science and Technology of China, Hefei, Anhui, 230026, China
| | - Emiliano Descrovi
- Department of Applied Science and Technology, Polytechnic University of Turin, Corso Daca degli Abruzzi 24, 10129 Turin, Italy
| | - Angelo Angelini
- Department of Applied Science and Technology, Polytechnic University of Turin, Corso Daca degli Abruzzi 24, 10129 Turin, Italy
| | - Yiping Huo
- Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology, University of Maryland School of Medicine, 725 West Lombard Street, Baltimore, MD 21201, USA
| | - Joseph R. Lakowicz
- Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology, University of Maryland School of Medicine, 725 West Lombard Street, Baltimore, MD 21201, USA
| |
Collapse
|
9
|
Lee S, Srinivasan B, Vemulapati S, Mehta S, Erickson D. Personalized nutrition diagnostics at the point-of-need. LAB ON A CHIP 2016; 16:2408-2417. [PMID: 27272753 DOI: 10.1039/c6lc00393a] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Micronutrient deficiency is widespread and negatively impacts morbidity, mortality, and quality of life globally. On-going advancements in nutritional biomarker discovery are enabling objective and accurate assessment of an individual's micronutrient and broader nutritional status. The vast majority of such assessment however still needs to be conducted in traditional centralized laboratory facilities which are not readily accessible in terms of cost and time in both the developed and developing countries. Lab-on-a-chip (LOC) technologies are enabling an increasing number of biochemical reactions at the point-of-need (PON) settings, and can significantly improve the current predicament in nutrition diagnostics by allowing rapid evaluation of one's nutritional status and providing an easy feedback mechanism for tracking changes in diet or supplementation. We believe that nutrition diagnostics represents a particularly appealing opportunity over other PON applications for two reasons: (1) healthy ranges for many micronutrients are well defined which allows for an unbiased diagnosis, and (2) many deficiencies can be reversed through changes in diet or supplementation before they become severe. In this paper, we provide background on nutritional biomarkers used in nutrition diagnostics and review the emerging technologies that exploit them at the point-of-need.
Collapse
Affiliation(s)
- Seoho Lee
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY 14853, USA.
| | | | | | | | | |
Collapse
|
10
|
Choi S. Powering point-of-care diagnostic devices. Biotechnol Adv 2016; 34:321-30. [DOI: 10.1016/j.biotechadv.2015.11.004] [Citation(s) in RCA: 79] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2015] [Revised: 11/24/2015] [Accepted: 11/25/2015] [Indexed: 12/22/2022]
|
11
|
Xing X, Liu W, Li T, Xing S, Fu X, Wu D, Liu D, Wang Z. A portable optical waveguide resonance light-scattering scanner for microarray detection. Analyst 2015; 141:199-205. [PMID: 26567521 DOI: 10.1039/c5an01839k] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
In the present work, a portable and low-cost planar waveguide based resonance light scattering (RLS) scanner (termed as: PW-RLS scanner) has been developed for microarray detection. The PW-RLS scanner employs a 2 × 4 white light emitting diode array (WLEDA) as the excitation light source, a folded optical path with a complementary metal oxide semiconductor (CMOS) as the signal/image acquisition device and stepper motors with gear drives as the mechanical drive system. The biological binding/recognizing events on the microarray can be detected with an evanescent waveguide-directed illumination and light-scattering label (e.g., nanoparticles) while the microarray slide acts as an evanescent waveguide substrate. The performance of the as-developed PW-RLS scanner has been evaluated by analyzing type 2 diabetes mellitus (T2DM) risk genes. Highly selective and sensitive (less than 1% allele frequency at the attomole-level) T2DM risk gene detection is achieved using single-stranded DNA functionalized gold nanoparticles (ssDNA-GNPs) as detection probes. Additionally, the successful simultaneous analysis of 15 T2DM patient genotypes suggests that the device has great potential for the realization of a personalized diagnostic test for a given disease or patient follow-up.
Collapse
Affiliation(s)
- Xuefeng Xing
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, P. R. China.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Klapproth H, Bednar S, Baader J, Lehmann M, Freund I, Brandstetter T, Rühe J. Development of a multi-analyte CMOS sensor for point-of-care testing. SENSING AND BIO-SENSING RESEARCH 2015. [DOI: 10.1016/j.sbsr.2015.08.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
|
13
|
Díaz-González M, Salvador JP, Bonilla D, Marco MP, Fernández-Sánchez C, Baldi A. A microfluidic device for the automated electrical readout of low-density glass-slide microarrays. Biosens Bioelectron 2015. [PMID: 26210466 DOI: 10.1016/j.bios.2015.07.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Microarrays are a powerful platform for rapid and multiplexed analysis in a wide range of research fields. Electrical readout systems have emerged as an alternative to conventional optical methods for microarray analysis thanks to its potential advantages like low-cost, low-power and easy miniaturization of the required instrumentation. In this work an automated electrical readout system for low-cost glass-slide microarrays is described. The system enables the simultaneous conductimetric detection of up to 36 biorecognition events by incorporating an array of interdigitated electrode transducers. A polydimethylsiloxane microfluidic structure has been designed that creates microwells over the transducers and incorporates the microfluidic channels required for filling and draining them with readout and cleaning solutions, thus making the readout process fully automated. Since the capture biomolecules are not immobilized on the transducer surface this readout system is reusable, in contrast to previously reported electrochemical microarrays. A low-density microarray based on a competitive enzymatic immunoassay for atrazine detection was used to test the performance of the readout system. The electrical assay shows a detection limit of 0.22±0.03 μg L(-1) similar to that obtained with fluorescent detection and allows the direct determination of the pesticide in polluted water samples. These results proved that an electrical readout system such as the one presented in this work is a reliable and cost-effective alternative to fluorescence scanners for the analysis of low-density microarrays.
Collapse
Affiliation(s)
- María Díaz-González
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Spain.
| | - J Pablo Salvador
- Nanobiotechnology for Diagnostics (Nb4D) Group, IQAC-CSIC, Jordi Girona 18-26, 08034 Barcelona, Spain
| | - Diana Bonilla
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Spain
| | - M Pilar Marco
- Nanobiotechnology for Diagnostics (Nb4D) Group, IQAC-CSIC, Jordi Girona 18-26, 08034 Barcelona, Spain
| | - César Fernández-Sánchez
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Spain
| | - Antoni Baldi
- Instituto de Microelectrónica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Barcelona, Spain
| |
Collapse
|
14
|
Mendez MH, Joh DY, Gupta R, Polascik TJ. Current Trends and New Frontiers in Focal Therapy for Localized Prostate Cancer. Curr Urol Rep 2015; 16:35. [DOI: 10.1007/s11934-015-0513-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
15
|
Hu Z, Glidle A, Ironside C, Cooper JM, Yin H. An integrated microspectrometer for localised multiplexing measurements. LAB ON A CHIP 2015; 15:283-289. [PMID: 25367674 DOI: 10.1039/c4lc00952e] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We describe the development of an integrated lensed Arrayed Waveguide Grating (AWG) microspectrometer for localized multiplexing fluorescence measurements. The device, which has a footprint that is only 1 mm wide and 1 cm long, is capable of spectroscopic measurements on chip. Multiple fluorescence signals were measured simultaneously based upon simple intensity readouts from a CCD camera. We also demonstrate the integration of the AWG spectrometer with a microfluidic platform using a lensing function to confine the beam shape for focused illumination. This capability enhances signal collection, gives better spatial resolution, and provides a route for the analysis of small volume samples (e.g. cells) in flow. To show these capabilities we developed a novel "bead-AWG" platform with which we demonstrate localized multiplexed fluorescence detection either simultaneously or successively. Such an integrated system provides the basis for a portable system capable of optical detection of multi-wavelength fluorescence from a single defined location.
Collapse
Affiliation(s)
- Zhixiong Hu
- Division of Biomedical Engineering, School of Engineering, University of Glasgow, Glasgow, UK.
| | | | | | | | | |
Collapse
|
16
|
Pérez JM, Jofre M, Martínez P, Yáñez MA, Catalan V, Pruneri V. An image cytometer based on angular spatial frequency processing and its validation for rapid detection and quantification of waterborne microorganisms. Analyst 2015; 140:7734-41. [DOI: 10.1039/c5an01338k] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Image cytometer based on angular spatial frequency processing for the early detection of waterborne bacteria.
Collapse
Affiliation(s)
- J. M. Pérez
- ICFO-Institut de Ciencies Fotoniques
- The Barcelona Institute of Science and Technology
- 08860 Castelldefels
- Spain
| | - M. Jofre
- ICFO-Institut de Ciencies Fotoniques
- The Barcelona Institute of Science and Technology
- 08860 Castelldefels
- Spain
| | - P. Martínez
- ICFO-Institut de Ciencies Fotoniques
- The Barcelona Institute of Science and Technology
- 08860 Castelldefels
- Spain
| | | | | | - V. Pruneri
- ICFO-Institut de Ciencies Fotoniques
- The Barcelona Institute of Science and Technology
- 08860 Castelldefels
- Spain
- ICREA – Institució Catalana de Recerca i Estudis Avançats
| |
Collapse
|
17
|
An Optofluidic Lens Array Microchip for High Resolution Stereo Microscopy. MICROMACHINES 2014. [DOI: 10.3390/mi5030607] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
18
|
A fast and simple label-free immunoassay based on a smartphone. Biosens Bioelectron 2014; 58:395-402. [DOI: 10.1016/j.bios.2014.02.077] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2013] [Revised: 02/14/2014] [Accepted: 02/27/2014] [Indexed: 11/24/2022]
|
19
|
Integrated planar optical waveguide interferometer biosensors: A comparative review. Biosens Bioelectron 2014; 58:287-307. [DOI: 10.1016/j.bios.2014.02.049] [Citation(s) in RCA: 215] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2013] [Revised: 02/10/2014] [Accepted: 02/11/2014] [Indexed: 02/04/2023]
|