1
|
Martínez-Moro R, Vázquez L, Pérez M, Del Pozo M, Vilas-Varela M, Castro-Esteban J, Petit-Domínguez MD, Casero E, Quintana C. Enhanced Electrochemical Detection of Nonelectroactive Compounds Based on Surface Supramolecular Interactions on Chevron-like Graphene Nanoribbons Modified through Click Chemistry. ACS OMEGA 2024; 9:39242-39252. [PMID: 39310175 PMCID: PMC11411676 DOI: 10.1021/acsomega.4c06639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2024] [Accepted: 08/02/2024] [Indexed: 09/25/2024]
Abstract
In this study, we have developed a nanostructured electrochemical sensor based on modified graphene nanoribbons tailored for the analysis of nonelectroactive compounds via a surface competitive assay. Stigmasterol, a nonelectroactive phytosterol, was selected as a representative case. Chevron-like graphene nanoribbons, chemically synthesized, were immobilized onto glassy carbon electrodes and covalently functionalized to allow the on-surface formation of a supramolecular complex. To this end, the nanoribbons were first modified through a diazotization process by electrochemical reduction of a 4-azidoaniline diazonium salt, leaving the electrode surface with azide groups exposed to solution. Next, the incorporation of a ferrocene group, as a redox probe, was carried out by a click chemistry reaction between ethynylferrocene and these azide groups. Finally, the recognition event leads to the formation of a supramolecular complex between ferrocene and a macrocyclic receptor on the electrode surface. To this end, the receptors cucurbit[7]uril, cucurbit[8]uril, and β-cyclodextrin were evaluated, with the better results obtained with β-cyclodextrin. Atomic force microscopy and scanning electron microscopy measurements were performed for the morphological characterization of the resulting electrochemical platform surface. The ability of β-cyclodextrin to form an inclusion complex with ferrocene or with stigmasterol allows to perform a competitive assay, which translates into the decrease and recovery of the ferrocene electrochemical signal. For stigmasterol determination, a linear concentration range between 200 and 750 μM and a detection limit of 60 μM were obtained, with relative errors and relative standard deviations less than 7.1 and 9.8%, respectively.
Collapse
Affiliation(s)
- Rut Martínez-Moro
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/Francisco Tomás y Valiente, No. 7, Madrid 28049, Spain
| | - Luis Vázquez
- Instituto de Ciencia de Materiales de Madrid (ICMM), CSIC, Campus de Excelencia de la Universidad Autónoma de Madrid, c/Sor Juana Inés de la Cruz, No. 3, Madrid 28049, Spain
| | - María Pérez
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/Francisco Tomás y Valiente, No. 7, Madrid 28049, Spain
| | - María Del Pozo
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/Francisco Tomás y Valiente, No. 7, Madrid 28049, Spain
| | - Manuel Vilas-Varela
- Centro Singular de Investigación en Química Biolóxica e Materiais Moleculares (CIQUS) and Departamento de Química Orgánica, Universidade de Santiago de Compostela, Santiago de Compostela 15782, Spain
| | - Jesús Castro-Esteban
- Centro Singular de Investigación en Química Biolóxica e Materiais Moleculares (CIQUS) and Departamento de Química Orgánica, Universidade de Santiago de Compostela, Santiago de Compostela 15782, Spain
| | - M Dolores Petit-Domínguez
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/Francisco Tomás y Valiente, No. 7, Madrid 28049, Spain
| | - Elena Casero
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/Francisco Tomás y Valiente, No. 7, Madrid 28049, Spain
| | - Carmen Quintana
- Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, Campus de Excelencia de la Universidad Autónoma de Madrid, c/Francisco Tomás y Valiente, No. 7, Madrid 28049, Spain
| |
Collapse
|
2
|
Redondo-Gómez C, Parreira P, Martins MCL, Azevedo HS. Peptide-based self-assembled monolayers (SAMs): what peptides can do for SAMs and vice versa. Chem Soc Rev 2024; 53:3714-3773. [PMID: 38456490 DOI: 10.1039/d3cs00921a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2024]
Abstract
Self-assembled monolayers (SAMs) represent highly ordered molecular materials with versatile biochemical features and multidisciplinary applications. Research on SAMs has made much progress since the early begginings of Au substrates and alkanethiols, and numerous examples of peptide-displaying SAMs can be found in the literature. Peptides, presenting increasing structural complexity, stimuli-responsiveness, and biological relevance, represent versatile functional components in SAMs-based platforms. This review examines the major findings and progress made on the use of peptide building blocks displayed as part of SAMs with specific functions, such as selective cell adhesion, migration and differentiation, biomolecular binding, advanced biosensing, molecular electronics, antimicrobial, osteointegrative and antifouling surfaces, among others. Peptide selection and design, functionalisation strategies, as well as structural and functional characteristics from selected examples are discussed. Additionally, advanced fabrication methods for dynamic peptide spatiotemporal presentation are presented, as well as a number of characterisation techniques. All together, these features and approaches enable the preparation and use of increasingly complex peptide-based SAMs to mimic and study biological processes, and provide convergent platforms for high throughput screening discovery and validation of promising therapeutics and technologies.
Collapse
Affiliation(s)
- Carlos Redondo-Gómez
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, Porto, 4200-135, Portugal.
- INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, Porto, 4200-135, Portugal
| | - Paula Parreira
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, Porto, 4200-135, Portugal.
- INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, Porto, 4200-135, Portugal
| | - M Cristina L Martins
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, Porto, 4200-135, Portugal.
- INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, Porto, 4200-135, Portugal
- ICBAS - Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Rua de Jorge Viterbo Ferreira, 4050-313 Porto, Portugal
| | - Helena S Azevedo
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, Porto, 4200-135, Portugal.
- INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, Porto, 4200-135, Portugal
| |
Collapse
|
3
|
Amiri A, Abedanzadeh S, Davaeil B, Shaabani A, Moosavi-Movahedi AA. Protein click chemistry and its potential for medical applications. Q Rev Biophys 2024; 57:e6. [PMID: 38619322 DOI: 10.1017/s0033583524000027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/16/2024]
Abstract
A revolution in chemical biology occurred with the introduction of click chemistry. Click chemistry plays an important role in protein chemistry modifications, providing specific, sensitive, rapid, and easy-to-handle methods. Under physiological conditions, click chemistry often overlaps with bioorthogonal chemistry, defined as reactions that occur rapidly and selectively without interfering with biological processes. Click chemistry is used for the posttranslational modification of proteins based on covalent bond formations. With the contribution of click reactions, selective modification of proteins would be developed, representing an alternative to other technologies in preparing new proteins or enzymes for studying specific protein functions in different biological processes. Click-modified proteins have potential in diverse applications such as imaging, labeling, sensing, drug design, and enzyme technology. Due to the promising role of proteins in disease diagnosis and therapy, this review aims to highlight the growing applications of click strategies in protein chemistry over the last two decades, with a special emphasis on medicinal applications.
Collapse
Affiliation(s)
- Ahmad Amiri
- Institute of Biochemistry and Biophysics (IBB), University of Tehran, Tehran, Iran
| | | | - Bagher Davaeil
- Institute of Biochemistry and Biophysics (IBB), University of Tehran, Tehran, Iran
| | - Ahmad Shaabani
- Department of Chemistry, Shahid Beheshti University, Tehran, Iran
| | | |
Collapse
|
4
|
Milchram L, Soldo R, Regele V, Schönthaler S, Degeorgi M, Baumgartner S, Kopp E, Weinhäusel A. A novel click chemistry-based peptide ELISA protocol: development and technical evaluation. Biotechniques 2022; 72:134-142. [PMID: 35234537 DOI: 10.2144/btn-2021-0107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
ELISA is the current standard for (auto)antibody diagnostics. Once established, ELISA protocols can be easily adapted for novel antigens; however, peptide-based protocols are rarely available. Herein the authors describe the results of a technical investigation of an indirect ELISA protocol using peptides conjugated onto a protein carrier based on click chemistry and immobilized in standard plastics. The authors compared this approach with the common biotin-avidin system and obtained a slightly improved limit of detection for purified IgG of 25-100 ng/well compared with 25-1000 ng/well. Reproducibility and stability of the methodological approach were conducted for further technical characterization. Indirect ELISA using immunoreactive peptides conjugated to bovine serum albumin offers a reliable method that is complementary to standard plastics and plate readers.
Collapse
Affiliation(s)
- Lisa Milchram
- Competence Unit Molecular Diagnostics, Center for Health and Bioresources, Austrian Institute of Technology, Giefinggasse 4, Vienna, 1210, Austria
| | - Regina Soldo
- Competence Unit Molecular Diagnostics, Center for Health and Bioresources, Austrian Institute of Technology, Giefinggasse 4, Vienna, 1210, Austria
| | - Valerie Regele
- Competence Unit Molecular Diagnostics, Center for Health and Bioresources, Austrian Institute of Technology, Giefinggasse 4, Vienna, 1210, Austria
| | - Silvia Schönthaler
- Competence Unit Molecular Diagnostics, Center for Health and Bioresources, Austrian Institute of Technology, Giefinggasse 4, Vienna, 1210, Austria
| | - Markus Degeorgi
- Competence Unit Molecular Diagnostics, Center for Health and Bioresources, Austrian Institute of Technology, Giefinggasse 4, Vienna, 1210, Austria
| | - Sophie Baumgartner
- Competence Unit Molecular Diagnostics, Center for Health and Bioresources, Austrian Institute of Technology, Giefinggasse 4, Vienna, 1210, Austria
| | - Elena Kopp
- Competence Unit Molecular Diagnostics, Center for Health and Bioresources, Austrian Institute of Technology, Giefinggasse 4, Vienna, 1210, Austria
| | - Andreas Weinhäusel
- Competence Unit Molecular Diagnostics, Center for Health and Bioresources, Austrian Institute of Technology, Giefinggasse 4, Vienna, 1210, Austria
| |
Collapse
|
5
|
Aayanifard Z, Alebrahim T, Pourmadadi M, Yazdian F, Dinani HS, Rashedi H, Omidi M. Ultra pH-sensitive detection of total and free prostate-specific antigen using electrochemical aptasensor based on reduced graphene oxide/gold nanoparticles emphasis on TiO 2/carbon quantum dots as a redox probe. Eng Life Sci 2021; 21:739-752. [PMID: 34764826 PMCID: PMC8576073 DOI: 10.1002/elsc.202000118] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 04/30/2021] [Accepted: 08/10/2021] [Indexed: 12/20/2022] Open
Abstract
The development of a rapid, sensitive, and straightforward detection method of prostate-specific antigen (PSA) is indispensable for the early diagnosis of prostate cancer (PCa). This work relates an electrochemical method using functionalized single-stranded DNA aptamer to diagnose PCa and benign prostate hyperplasia. The sensing platform relies on PSA recognition by aptamer/Au/GO-nanohybrid-modified glassy carbon electrode. Besides ferrocyanide TiO2/carbon quantum dots (CQDs) probe is used to investigate the effect of nanoparticle-containing electrolyte. Optimization of incubation time of aptamer/Au/GO-nanohybrid and volume fraction of nafion were done using Design Expert 10 software reporting 42.4 h and 0.095% V/V, respectively. In ferrocyanide medium, PSA detection as low as 3, 2.96, and 0.85 ng mL-1 was achieved with a dynamic range from 0.5 to 7 ng ml-1, in accord with clinical values, using cyclic voltammetry, square wave voltammetry, and electrochemical impedance spectroscopy, respectively. Moreover, this sensor exhibited conspicuous performance in TiO2/CQDs-containing medium with different pH values of 5.4 and 8 to distinguish total PSA and free PSA, resulting in very low limit of detections, 0.028, and 0.007 ng ml-1, respectively. The results manifested the proposed system as a forthcoming sensor in a clinical and point of care analysis of PSA.
Collapse
Affiliation(s)
- Zahra Aayanifard
- School of Chemical EngineeringCollege of EngineeringUniversity of TehranTehranIran
| | - Talieh Alebrahim
- School of Chemical EngineeringCollege of EngineeringUniversity of TehranTehranIran
| | | | - Fatemeh Yazdian
- Department of Life Science EngineeringFaculty of New Science and TechnologiesUniversity of TehranTehranIran
| | | | - Hamid Rashedi
- School of Chemical EngineeringCollege of EngineeringUniversity of TehranTehranIran
| | - Meisam Omidi
- Protein Research CenterShahid Beheshti UniversityTehranIran
| |
Collapse
|
6
|
Gao R, Liu B, Luo D, Su Y, Su L. Enhanced Immunosensor Using a Handheld pH Meter for the Point‐of‐Care, Sensitive Detection of Prostate Specific Antigen. ELECTROANAL 2021. [DOI: 10.1002/elan.202100285] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
- Rong Gao
- Engineering Laboratory for Synthetic Drugs (Ministry of Education of Guizhou Province) College of Pharmacy Guizhou University Guizhou 550025 PR China
| | - Bingqian Liu
- Engineering Laboratory for Synthetic Drugs (Ministry of Education of Guizhou Province) College of Pharmacy Guizhou University Guizhou 550025 PR China
| | - Dajuan Luo
- Engineering Laboratory for Synthetic Drugs (Ministry of Education of Guizhou Province) College of Pharmacy Guizhou University Guizhou 550025 PR China
| | - Yonghuan Su
- Engineering Laboratory for Synthetic Drugs (Ministry of Education of Guizhou Province) College of Pharmacy Guizhou University Guizhou 550025 PR China
| | - Lixia Su
- Engineering Laboratory for Synthetic Drugs (Ministry of Education of Guizhou Province) College of Pharmacy Guizhou University Guizhou 550025 PR China
| |
Collapse
|
7
|
Park S, Shin J, Kwon J, Lee W, Kim J, Kim G, Joo JM, Yang H. Interference-Free Duplex Detection of Total and Active Enzyme Concentrations at a Single Working Electrode. ACS Sens 2021; 6:1305-1311. [PMID: 33491444 DOI: 10.1021/acssensors.0c02597] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The duplex detection of both total and active enzyme concentrations without interferences at a single working electrode is challenging, especially when two different assays are combined. It is also challenging to obtain two different redox-cycling reactions without interference. Here, we present a simple but sensitive combined assay that is based on two redox-cycling reactions using two incubation periods and applied potentials at a single electrode. The assay combines an immunoassay for the determination of the total enzyme (total prostate-specific antigen, tPSA) concentration with a protease assay for the determination of the active enzyme (free PSA, fPSA) concentration. The immunoassay label and fPSA that are affinity-bound to the electrode are used for high sensitivity and specificity in the protease assay as well as the immunoassay. In the immunoassay, electrochemical-enzymatic (EN) redox cycling involving ferrocenemethanol is obtained at 0.1 V versus Ag/AgCl without incubation before the proteolytically released 4-amino-1-naphthol is generated. In the protease assay, EN redox cycling involving 4-amino-1-naphthol is obtained at 0.0 V after 30 min of incubation without ferrocenemethanol electro-oxidation. The detection procedure is almost the same as common electrochemical sandwich-type immunoassays, although the two different assays are combined. The duplex detection in buffer and serum is highly interference-free, specific, and sensitive. The detection limits for tPSA and fPSA are approximately 10 and 1 pg/mL, respectively.
Collapse
Affiliation(s)
- Seonhwa Park
- Department of Chemistry, Pusan National University, Busan 46241, Korea
| | - Jeonghwa Shin
- Department of Chemistry, Pusan National University, Busan 46241, Korea
| | - Jungwook Kwon
- Department of Chemistry, Pusan National University, Busan 46241, Korea
| | - Woohyeong Lee
- Department of Chemistry, Pusan National University, Busan 46241, Korea
| | - Jihyeon Kim
- Department of Chemistry, Pusan National University, Busan 46241, Korea
| | - Gyeongho Kim
- Department of Chemistry, Pusan National University, Busan 46241, Korea
| | - Jung Min Joo
- Department of Chemistry, Pusan National University, Busan 46241, Korea
| | - Haesik Yang
- Department of Chemistry, Pusan National University, Busan 46241, Korea
| |
Collapse
|
8
|
Vanova V, Mitrevska K, Milosavljevic V, Hynek D, Richtera L, Adam V. Peptide-based electrochemical biosensors utilized for protein detection. Biosens Bioelectron 2021; 180:113087. [PMID: 33662844 DOI: 10.1016/j.bios.2021.113087] [Citation(s) in RCA: 72] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Revised: 02/04/2021] [Accepted: 02/10/2021] [Indexed: 02/07/2023]
Abstract
Proteins are generally detected as biomarkers for tracing or determining various disorders in organisms. Biomarker proteins can be tracked in samples with various origins and in different concentrations, revealing whether an organism is in a healthy or unhealthy state. In regard to detection, electrochemical biosensors are a potential fusion of electronics, chemistry, and biology, allowing for fast and early point-of-care detection from a biological sample with the advantages of high sensitivity, simple construction, and easy operation. Peptides present a promising approach as a biorecognition element when connected with electrochemical biosensors. The benefits of short peptides lie mainly in their good stability and selective affinity to a target analyte. Therefore, peptide-based electrochemical biosensors (PBEBs) represent an alternative approach for the detection of different protein biomarkers. This review provides a summary of the past decade of recently proposed PBEBs designed for protein detection, dividing them according to different protein types: (i) enzyme detection, including proteases and kinases; (ii) antibody detection; and (iii) other protein detection. According to these protein types, different sensing mechanisms are discussed, such as the peptide cleavage by a proteases, phosphorylation by kinases, presence of antibodies, and exploiting of affinities; furthermore, measurements are obtained by different electrochemical methods. A discussion and comparison of various constructions, modifications, immobilization strategies and different sensing techniques in terms of high sensitivity, selectivity, repeatability, and potential for practical application are presented.
Collapse
Affiliation(s)
- Veronika Vanova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Katerina Mitrevska
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Vedran Milosavljevic
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 61 200, Brno, Czech Republic
| | - David Hynek
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 61 200, Brno, Czech Republic
| | - Lukas Richtera
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 61 200, Brno, Czech Republic
| | - Vojtech Adam
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 61 200, Brno, Czech Republic.
| |
Collapse
|
9
|
Dowlatshahi S, Abdekhodaie MJ. Electrochemical prostate-specific antigen biosensors based on electroconductive nanomaterials and polymers. Clin Chim Acta 2021; 516:111-135. [PMID: 33545110 DOI: 10.1016/j.cca.2021.01.018] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 01/23/2021] [Accepted: 01/26/2021] [Indexed: 01/11/2023]
Abstract
Prostate cancer (PCa), the second most malignant neoplasm in men, is also the fifth leading cause of cancer-related deaths in men globally. Unfortunately, this malignancy remains largely asymptomatic until late-stage emergence when treatment is limited due to the lack of effective metastatic PCa therapeutics. Due to these limitations, early PCa detection through prostate-specific antigen (PSA) screening has become increasingly important, resulting in a more than 50% decrease in mortality. Conventional assays for PSA detection, such as enzyme-linked immunosorbent assay (ELISA), are labor intensive, relatively expensive, operator-dependent and do not provide adequate sensitivity. Electrochemical biosensors overcome these limitations because they are rapid, cost-effective, simple to use and ultrasensitive. This article reviews electrochemical PSA biosensors using electroconductive nanomaterials such as carbon-, metal-, metal oxide- and peptide-based nanostructures, as well as polymers to significantly improve conductivity and enhance sensitivity. Challenges associated with the development of these devices are discussed thus providing additional insight into their analytic strength as well as their potential use in early PCa detection.
Collapse
Affiliation(s)
- Sayeh Dowlatshahi
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Mohammad J Abdekhodaie
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran; Yeates School of Graduate Studies, Ryerson University, Toronto, Ontario, Canada.
| |
Collapse
|
10
|
Hu Q, Gan S, Bao Y, Zhang Y, Han D, Niu L. Electrochemically Controlled ATRP for Cleavage-Based Electrochemical Detection of the Prostate-Specific Antigen at Femtomolar Level Concentrations. Anal Chem 2020; 92:15982-15988. [PMID: 33225684 DOI: 10.1021/acs.analchem.0c03467] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
As a single-chain glycoprotein with endopeptidase activity, the prostate-specific antigen (PSA) is valuable as an informative serum marker in diagnosing, staging, and prognosis of prostate cancer. In this report, an electrochemical biosensor based on the target-induced cleavage of a specific peptide substrate (PSA peptide) is designed for the highly selective detection of PSA at the femtomolar level, using electrochemically controlled atom transfer radical polymerization (eATRP) as a method for signal amplification. The PSA peptides, without free carboxyl sites, are attached to the gold surface via the N-terminal cysteine residue. The target-induced cleavage of PSA peptides results in the generation of carboxyl sites, to which the alkyl halide initiator α-bromophenylacetic acid (BPAA) is linked via the Zr(IV) linkers. Subsequently, the potentiostatic eATRP of ferrocenylmethyl methacrylate (FcMMA, as the monomer) leads to the surface-initiated grafting of high-density ferrocenyl polymers. As a result, a large amount of Fc redox tags can be recruited for signal amplification, through which the limit of detection (LOD) for PSA can be down to 3.2 fM. As the recognition element, the PSA peptide is easy to synthesize, chemically and thermally stable, and low-cost. Without the necessity of enzyme or nanoparticle labels, the eATRP-based amplification method is easy to operate and low-cost. Results also show that the cleavage-based electrochemical PSA biosensor is highly selective and applicable to PSA detection in complex biological samples. In view of these merits, the integration of the eATRP-based amplification method into cleavage-based recognition is believed to hold great promise for the electrochemical detection of PSA in clinical applications.
Collapse
Affiliation(s)
- Qiong Hu
- Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Shiyu Gan
- Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Yu Bao
- Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Yuwei Zhang
- Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Dongxue Han
- Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Li Niu
- Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| |
Collapse
|
11
|
An ultrasensitive label-free electrochemical immunosensor based on 3D porous chitosan-graphene-ionic liquid-ferrocene nanocomposite cryogel decorated with gold nanoparticles for prostate-specific antigen. Talanta 2020; 224:121787. [PMID: 33379016 DOI: 10.1016/j.talanta.2020.121787] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 10/12/2020] [Accepted: 10/15/2020] [Indexed: 12/14/2022]
Abstract
A highly sensitive and selective label-free electrochemical immunosensor was successfully fabricated for measuring prostate-specific antigen (PSA). A composite of chitosan, graphene, ionic liquid and ferrocene (CS-GR-IL-Fc) was drop casted onto a screen-printed carbon electrode (SPCE) and frozen to create a layer of 3D porous cryogel (CS-GR-IL-Fc cry) which was decorated with gold nanoparticles (AuNPs). The biocompatibility and porosity of the cryogel increased the surface area available for AuNPs loading via amino groups and the population of anti-PSA, immobilized on the AuNPs via chemisorption, could be increased. The CS-GR-IL-Fc cry displayed excellent conductivity, enhancing electron transfer and amplifying the current signal. Differential pulse voltammetry was employed to determine PSA by measuring the reduction in the Fc oxidation peak current in response to the formation of PSA/anti-PSA immunocomplex. Under the optimized incubation time and electrolyte pH, the developed immunosensor displayed excellent analytical performances, including a wide linear range at concentrations from 1.0 × 10-7 to 1.0 × 10-1 ng mL-1, with a very low limit of detection of 4.8 × 10-8 ng mL-1 and good reproducibility (relative standard deviation of <4.6%, n = 6), stability (90% sensitivity within 20 days), repeatability (12 cycles of binding-rebinding, the sensitivity > 90%) and selectivity. The results obtained from the device for the determination of PSA in human serum were consistent with results from the enzyme-linked immunosorbent assay (P > 0.05), and indicated the promising potential of the proposed immunosensor in clinical diagnosis.
Collapse
|
12
|
Svalova TS, Malysheva NN, Bubekova AK, Saigushkina AA, Medvedeva MV, Kozitsina AN. Effect of the Method for Immobilizing Receptor Layer on the Analytical Characteristics of a Label-Free Electrochemical Immunosensor for the Determination of Measles Antibodies. JOURNAL OF ANALYTICAL CHEMISTRY 2020. [DOI: 10.1134/s106193482002015x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
13
|
Negahdary M, Sattarahmady N, Heli H. Advances in prostate specific antigen biosensors-impact of nanotechnology. Clin Chim Acta 2020; 504:43-55. [PMID: 32004532 DOI: 10.1016/j.cca.2020.01.028] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 01/25/2020] [Accepted: 01/27/2020] [Indexed: 01/01/2023]
Abstract
Prostate cancer is one of the most dangerous and deadly cancers in elderly men. Early diagnosis using prostate-specific antigen (PSA) facilitates disease detection, management and treatment. Biosensors have recently been used as sensitive, selective, inexpensive and rapid diagnostic tools for PSA detection. In this review, a variety of PSA biosensors such as aptasensors, peptisensors and immunesensors are highlighted. These use aptamers, peptides and antibodies in the biorecognition element, respectively, and can detect PSA with very high sensitivity via electrochemical, electrochemiluminescence, fluorescence and surface-enhanced Raman spectroscopy. To improve the sensitivity of most of these PSA biosensors, different nanostructured materials have played a critical role.
Collapse
Affiliation(s)
- M Negahdary
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - N Sattarahmady
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran; Department of Medical Physics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - H Heli
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
| |
Collapse
|
14
|
Yáñez-Sedeño P, González-Cortés A, Campuzano S, Pingarrón JM. Copper(I)-Catalyzed Click Chemistry as a Tool for the Functionalization of Nanomaterials and the Preparation of Electrochemical (Bio)Sensors. SENSORS (BASEL, SWITZERLAND) 2019; 19:E2379. [PMID: 31137612 PMCID: PMC6566994 DOI: 10.3390/s19102379] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 05/20/2019] [Accepted: 05/22/2019] [Indexed: 01/30/2023]
Abstract
Proper functionalization of electrode surfaces and/or nanomaterials plays a crucial role in the preparation of electrochemical (bio)sensors and their resulting performance. In this context, copper(I)-catalyzed azide-alkyne cycloaddition (CuAAC) has been demonstrated to be a powerful strategy due to the high yields achieved, absence of by-products and moderate conditions required both in aqueous medium and under physiological conditions. This particular chemistry offers great potential to functionalize a wide variety of electrode surfaces, nanomaterials, metallophthalocyanines (MPcs) and polymers, thus providing electrochemical platforms with improved electrocatalytic ability and allowing the stable, reproducible and functional integration of a wide range of nanomaterials and/or different biomolecules (enzymes, antibodies, nucleic acids and peptides). Considering the rapid progress in the field, and the potential of this technology, this review paper outlines the unique features imparted by this particular reaction in the development of electrochemical sensors through the discussion of representative examples of the methods mainly reported over the last five years. Special attention has been paid to electrochemical (bio)sensors prepared using nanomaterials and applied to the determination of relevant analytes at different molecular levels. Current challenges and future directions in this field are also briefly pointed out.
Collapse
Affiliation(s)
- P Yáñez-Sedeño
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28040 Madrid, Spain.
| | - A González-Cortés
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28040 Madrid, Spain.
| | - S Campuzano
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28040 Madrid, Spain.
| | - J M Pingarrón
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28040 Madrid, Spain.
| |
Collapse
|
15
|
Fabrication of a novel and ultrasensitive label-free electrochemical aptasensor for detection of biomarker prostate specific antigen. Int J Biol Macromol 2019; 126:1065-1073. [PMID: 30611810 DOI: 10.1016/j.ijbiomac.2019.01.012] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 01/01/2019] [Accepted: 01/03/2019] [Indexed: 12/29/2022]
Abstract
In this study, a novel and efficient aptasensor based on immobilization of thiol terminated prostate specific antigen (PSA) binding DNA aptamer onto Au nanoparticles/fullerene C60-chitosan-ionic liquid/multiwalled carbon nanotubes/screen printed carbon electrode has been fabricated for ultrasensitive aptasensing of biomarker PSA. Formation of PSA-aptamer complex caused a variation in electrochemical impedance spectroscopic (EIS) and differential pulse voltammetric (DPV) responses of the aptasensor which enabled us to aptasensing of the PSA by EIS and DPV methods. Morphology and electrochemical properties of the fabricated aptasensor were examined by scanning electron microscopy (SEM), cyclic voltammetry (CV) and EIS. The aptasensor was successfully applied to the determination of PSA by EIS and DPV in the range of 1-200 pg mL-1 with a limit of detection (LOD) of 0.5 pg mL-1 and 2.5-90 ng mL-1 with a LOD of 1.5 ng mL-1, respectively. This aptasensor exhibited outstanding anti-interference ability towards co-existing molecules with good stability, sensitivity, repeatability and reproducibility. Practical application of the aptasensor was examined with analysis of the PSA levels in serum samples obtained from patients with prostate cancer using both the aptasensor and a reference method. The results revealed the proposed system to be a promising candidate for clinical analysis of PSA.
Collapse
|
16
|
A novel peptide/Fe3O4@SiO2-Au nanocomposite-based fluorescence biosensor for the highly selective and sensitive detection of prostate-specific antigen. Talanta 2018; 179:531-537. [DOI: 10.1016/j.talanta.2017.11.033] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2017] [Revised: 10/27/2017] [Accepted: 11/17/2017] [Indexed: 12/19/2022]
|
17
|
Yu Q, Wu Y, Liu Z, Lei S, Li G, Ye B. Novel electrochemical biosensor based on cationic peptide modified hemin/G-quadruples enhanced peroxidase-like activity. Biosens Bioelectron 2018; 107:178-183. [PMID: 29455028 DOI: 10.1016/j.bios.2018.02.014] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Revised: 02/02/2018] [Accepted: 02/02/2018] [Indexed: 12/21/2022]
Abstract
This work designed an artificial substrate peptide to synthesize peptide-hemin/G-quadruplex (peptide-DNAzyme) conjugates. In addition to enhancing catalytic activity of hemin/G-quadruplex, the peptide could also be induced and cleaved by prostate specific antigen (PSA). It was the first report on peptide-DNAzyme conjugates in application of the peptide biosensor. The polyethyleneimine-reduced graphene oxide@hollow platinum nanotubes (PEI-rGO@PtNTs) nanocomposites were cast on the glassy carbon electrode in order to form the interface of biocompatibility and huge surface area for bioprobes immobilization. In absence of PSA, the peptide-DNAzyme conjugates retained intact on the surface of the electrode to produce a strong response signal. But in presence of PSA, the peptide-DNAzyme conjugates were destroyed to release electron mediators, resulting in dramatical decrease of the electrochemicl signal. Therefore, the method had high sensitivity and super selectivity with the limit of detection calculated as 2.0 fg/mL. Furthermore, the strategy would be promising to apply for other proteases by transforming the synthetic peptide module of target.
Collapse
Affiliation(s)
- Qian Yu
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, PR China
| | - Yongmei Wu
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, PR China.
| | - Zi Liu
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, PR China
| | - Sheng Lei
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, PR China
| | - Gaiping Li
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, PR China
| | - Baoxian Ye
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, PR China.
| |
Collapse
|
18
|
Puiu M, Bala C. Peptide-based biosensors: From self-assembled interfaces to molecular probes in electrochemical assays. Bioelectrochemistry 2017; 120:66-75. [PMID: 29182910 DOI: 10.1016/j.bioelechem.2017.11.009] [Citation(s) in RCA: 61] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2017] [Revised: 11/21/2017] [Accepted: 11/21/2017] [Indexed: 02/06/2023]
Abstract
Redox-tagged peptides have emerged as functional materials with multiple applications in the area of sensing and biosensing applications due to their high stability, excellent redox properties and versatility of biomolecular interactions. They allow direct observation of molecular interactions in a wide range of affinity and enzymatic assays and act as electron mediators. Short helical peptides possess the ability to self-assemble in specific configurations with the possibility to develop in highly-ordered, stable 1D, 2D and 3D architectures in a hierarchical controlled manner. We provide here a brief overview of the electrochemical techniques available to study the electron transfer in peptide films with particular interest in developing biosensors with immobilized peptide motifs, for biological and clinical applications.
Collapse
Affiliation(s)
- Mihaela Puiu
- R&D Center LaborQ, University of Bucharest, 4-12 Regina Elisabeta Blvd., 030018 Bucharest, Romania
| | - Camelia Bala
- R&D Center LaborQ, University of Bucharest, 4-12 Regina Elisabeta Blvd., 030018 Bucharest, Romania; Department of Analytical Chemistry, University of Bucharest, 4-12 Regina Elisabeta Blvd., 030018 Bucharest, Romania.
| |
Collapse
|
19
|
Using reduced graphene oxide-Ca:CdSe nanocomposite to enhance photoelectrochemical activity of gold nanoparticles functionalized tungsten oxide for highly sensitive prostate specific antigen detection. Biosens Bioelectron 2017; 96:239-245. [DOI: 10.1016/j.bios.2017.04.052] [Citation(s) in RCA: 116] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2017] [Revised: 04/09/2017] [Accepted: 04/20/2017] [Indexed: 12/31/2022]
|
20
|
Damborska D, Bertok T, Dosekova E, Holazova A, Lorencova L, Kasak P, Tkac J. Nanomaterial-based biosensors for detection of prostate specific antigen. Mikrochim Acta 2017; 184:3049-3067. [PMID: 29109592 PMCID: PMC5669453 DOI: 10.1007/s00604-017-2410-1] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Screening serum for the presence of prostate specific antigen (PSA) belongs to the most common approach for the detection of prostate cancer. This review (with 156 refs.) addresses recent developments in PSA detection based on the use of various kinds of nanomaterials. It starts with an introduction into the field, the significance of testing for PSA, and on current limitations. A first main section treats electrochemical biosensors for PSA, with subsections on methods based on the use of gold electrodes, graphene or graphene-oxide, carbon nanotubes, hybrid nanoparticles, and other types of nanoparticles. It also covers electrochemical methods based on the enzyme-like activity of PSA, on DNA-, aptamer- and biofuel cell-based methods, and on the detection of PSA via its glycan part. The next main section covers optical biosensors, with subsections on methods making use of surface plasmon resonance (SPR), localized SPR and plasmonic ELISA-like schemes. This is followed by subsections on methods based on the use of fiber optics, fluorescence, chemiluminescence, Raman scattering and SERS, electrochemiluminescence and cantilever-based methods. The most sensitive biosensors are the electrochemical ones, with lowest limits of detection (down to attomolar concentrations), followed by mass cantilever sensing and electrochemilumenescent strategies. Optical biosensors show lower performance, but are still more sensitive compared to standard ELISA. The most commonly applied nanomaterials are metal and carbon-based ones and their hybrid composites used for different amplification strategies. The most attractive sensing schemes are summarized in a Table. The review ends with a section on conclusions and perspectives.
Collapse
Affiliation(s)
- Dominika Damborska
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Tomas Bertok
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Erika Dosekova
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Alena Holazova
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Lenka Lorencova
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Peter Kasak
- Center for Advanced Materials, Qatar University, P.O. Box 2713, Doha, Qatar
| | - Jan Tkac
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| |
Collapse
|
21
|
Yang K, Hu Y, Dong N, Zhu G, Zhu T, Jiang N. A novel SERS-based magnetic aptasensor for prostate specific antigen assay with high sensitivity. Biosens Bioelectron 2017; 94:286-291. [PMID: 28292735 DOI: 10.1016/j.bios.2017.02.048] [Citation(s) in RCA: 74] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2016] [Revised: 02/07/2017] [Accepted: 02/28/2017] [Indexed: 12/21/2022]
Abstract
The accurate and highly sensitive detection of prostate specific antigen (PSA) is particularly important, especially for obese men and patients. In this report, we present a novel aptamer-based surface-enhanced Raman scattering (SERS) sensor that employs magnetic nanoparticles (MNPs) core-Au nanoparticles (AuNPs) satellite assemblies to detect PSA. The high specific biorecognition between aptamer and PSA caused the dissolution of the core-satellite assemblies, thus the concentration of functionalized AuNPs (signal probes) existing in the supernatant was on the rise with the continual addition of PSA. The aptamer-modified MNPs were used as supporting materials and separation tools in the present sensor. With the assistance of magnet, the mixture was removed from the supernatant for the concentration effects. It was found that the corresponding SERS signals from the supernatant were in direct correlation to PSA concentrations over a wide range and the limit of detection (LOD) was as low as 5.0pg/mL. Excellent recovery was also obtained to assess the feasibility of this method for human serum samples detection. All of these results show a promising application of this method. And this novel sensor can be used for the accurate and highly sensitive detection of PSA in clinic samples in the future.
Collapse
Affiliation(s)
- Kang Yang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Yongjun Hu
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
| | - Ning Dong
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Guichi Zhu
- Laboratory of Biosensors & Nanomachines, Département de Chimie, Université de Montréal, Québec, Canada
| | - Tingfeng Zhu
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Ningjing Jiang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| |
Collapse
|
22
|
Parnsubsakul A, Safitri RE, Rijiravanich P, Surareungchai W. Electrochemical assay of proteolytically active prostate specific antigen based on anodic stripping voltammetry of silver enhanced gold nanoparticle labels. J Electroanal Chem (Lausanne) 2017. [DOI: 10.1016/j.jelechem.2016.12.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
23
|
Heydari-Bafrooei E, Shamszadeh NS. Electrochemical bioassay development for ultrasensitive aptasensing of prostate specific antigen. Biosens Bioelectron 2016; 91:284-292. [PMID: 28033557 DOI: 10.1016/j.bios.2016.12.048] [Citation(s) in RCA: 68] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2016] [Revised: 12/19/2016] [Accepted: 12/20/2016] [Indexed: 01/22/2023]
Abstract
A densely packed gold nanoparticles on the rGO-MWCNT platform was used as the basis for an ultrasensitive label-free electrochemical aptasensor to detect the biomarker prostate specific antigen (PSA) in serum. The detection was based on that the variation of electron transfer resistance (Rct) and differential pulse voltammetry (DPV) current were relevant to the formation of PSA-aptamer complex at the modified electrode surface. Compared with pure AuNPs, rGO-MWCNT and MWCNT/AuNPs, the rGO-MWCNT/AuNPs nanocomposite modified electrode was the most sensitive aptasensing platform for the determination of PSA. Two calibration curves were prepared from the data obtained from the DPV and electrochemical impedance spectroscopy (EIS) by plotting the peak current and Rct against PSA concentration, respectively. The proposed aptasensor had an extremely low LOD of 1.0pgmL-1 PSA within the detection range of 0.005-20ngmL-1 and 0.005-100ngmL-1 for DPV and EIS calibration curves, respectively. This sensor exhibited outstanding anti-interference ability towards co-existing molecules with good stability, sensitivity, and reproducibility. Clinical application was performed with analysis of the PSA levels in serum samples obtained from patients with prostate cancer using both the aptasensor and Immunoradiometric assay. The results revealed the proposed system to be a promising candidate for clinical analysis of PSA.
Collapse
Affiliation(s)
- Esmaeil Heydari-Bafrooei
- Department of Chemistry, Faculty of Science, Vali-e-Asr University of Rafsanjan, 77188-97111, Iran; High Temperature Fuel Cell Research Group, Vali-e-Asr University of Rafsanjan, 77188-97111, Iran.
| | - Nazgol Sadat Shamszadeh
- Department of Chemistry, Faculty of Science, Vali-e-Asr University of Rafsanjan, 77188-97111, Iran
| |
Collapse
|
24
|
Pham-Truong TN, Lafolet F, Ghilane J, Randriamahazaka H. Surface functionalization with redox active molecule-based imidazolium via click chemistry. Electrochem commun 2016. [DOI: 10.1016/j.elecom.2016.06.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
25
|
Rahi A, Sattarahmady N, Heli H. Label-free electrochemical aptasensing of the human prostate-specific antigen using gold nanospears. Talanta 2016; 156-157:218-224. [PMID: 27260456 DOI: 10.1016/j.talanta.2016.05.029] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 04/03/2016] [Accepted: 05/05/2016] [Indexed: 12/22/2022]
Abstract
Gold nanospears were electrodeposited with the assistance of arginine as a soft template and precise selection of experimental parameters. The nanospears were then employed as a transducer to immobilize an aptamer of prostate-specific antigen (PSA) and fabrication of a label-free electrochemical aptasensor. The aptasensor was employed for the detection of PSA with a linear concentration range of 0.125-200ngmL(-1) and a limit of detection of 50pgmL(-1). The aptasensor was successfully applied to detect PSA in blood serum samples of healthy and patient persons.
Collapse
Affiliation(s)
- A Rahi
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - N Sattarahmady
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran; Department of Medical Physics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - H Heli
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
| |
Collapse
|