1
|
Li J, Zhao S, Bai L, Liu X, Shang L. Ratiometric fluorescence aptasensor for lysozyme based on the controllable excimer formation of perylene probe. Talanta 2025; 286:127521. [PMID: 39756257 DOI: 10.1016/j.talanta.2025.127521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2024] [Revised: 12/30/2024] [Accepted: 01/01/2025] [Indexed: 01/07/2025]
Abstract
As an important biological indicator, the abnormity of the lysozyme level is closely related to many diseases. Herein, we devise a novel ratiometric fluorescence aptasensor for lysozyme based on the controllable excimer formation of a perylene probe, N, N'-bis(6-caproic acid)-3,4:9,10-perylene diimide (PDI) induced by cationic silver nanoparticles (Ag NPs). Binding of lysozyme aptamer with multiple phosphate groups to cationic Ag NPs strongly hinders the formation of excimer, yielding intense monomer fluorescence of PDI probe. With the introduction of lysozyme, the adsorption of aptamer on the surface of Ag NPs will be weakened owing to the specific interactions between aptamer and lysozyme, which greatly facilitates the excimer formation of PDI. Based on the monomer-excimer transition triggered by lysozyme, ratiometric fluorescence aptasensor for lysozyme can be established. A good linear relationship between the ratio of monomer intensity to excimer intensity and the logarithm of lysozyme concentration was obtained in the range of 0.25-15 nM, and as few as 0.25 nM lysozyme could be easily detected. Moreover, excellent selectivity for lysozyme detection and satisfactory results in real sample analysis were also achieved. This work provides an innovative platform for the construction of simple, label-free ratiometric fluorescence sensors towards a wide range of analytes based on perylene probe.
Collapse
Affiliation(s)
- Juanmin Li
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an, 710054, PR China
| | - Shunsheng Zhao
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an, 710054, PR China
| | - Lihua Bai
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an, 710054, PR China
| | - Xiangrong Liu
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an, 710054, PR China
| | - Li Shang
- State Key Laboratory of Solidification Processing, School of Materials Science and Engineering, Northwestern Polytechnical University, Xi'an, 710072, PR China.
| |
Collapse
|
2
|
D'Agata R, Bellassai N, Spoto G. Exploiting the design of surface plasmon resonance interfaces for better diagnostics: A perspective review. Talanta 2024; 266:125033. [PMID: 37562226 DOI: 10.1016/j.talanta.2023.125033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 08/01/2023] [Accepted: 08/03/2023] [Indexed: 08/12/2023]
Abstract
Surface Plasmon Resonance based-sensors are promising tools for precision diagnostics as they can provide tests useful for early and, whenever possible, non-invasive disease detection and monitoring. The design of novel, robust and effective interfaces enabling the sensing of a variety of molecular interactions in a highly selective and sensitive manner is a necessary step to obtain both accurate and reliable detection by SPR. This review covers the recent research efforts in this area, specifically emphasizing well-designed interfaces and applications in real-life samples. In particular, after a short introduction which identifies some of the critical challenges, the emerging strategies for the integration of the linker, the metal substrate and the recognition element on the sensing interface will be explored and discussed in three sections, as well as the opportunities for building SPR biosensors, easy to use, and with excellent sensitivities. Finally, a summary of some of the more promising and latest diagnostic applications will be provided, presenting a new window into the near-future perspectives.
Collapse
Affiliation(s)
- Roberta D'Agata
- Department of Chemical Sciences, University of Catania, Viale Andrea Doria, 6, 95125, Catania, Italy; INBB, Istituto Nazionale di Biostrutture e Biosistemi, Viale Delle Medaglie D'Oro, 305, 00136, Roma, Italy.
| | - Noemi Bellassai
- Department of Chemical Sciences, University of Catania, Viale Andrea Doria, 6, 95125, Catania, Italy; INBB, Istituto Nazionale di Biostrutture e Biosistemi, Viale Delle Medaglie D'Oro, 305, 00136, Roma, Italy
| | - Giuseppe Spoto
- Department of Chemical Sciences, University of Catania, Viale Andrea Doria, 6, 95125, Catania, Italy; INBB, Istituto Nazionale di Biostrutture e Biosistemi, Viale Delle Medaglie D'Oro, 305, 00136, Roma, Italy
| |
Collapse
|
3
|
Akgönüllü S, Denizli A. Plasmonic nanosensors for pharmaceutical and biomedical analysis. J Pharm Biomed Anal 2023; 236:115671. [PMID: 37659267 DOI: 10.1016/j.jpba.2023.115671] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Revised: 08/04/2023] [Accepted: 08/17/2023] [Indexed: 09/04/2023]
Abstract
The detection and identification of clinical biomarkers with related sensitivity have become a source of considerable concern for biomedical analysis. There have been increasing efforts toward the development of single-molecule analytical platforms to overcome this concern. The latest developments in plasmonic nanomaterials include fascinating advances in energy, catalyst chemistry, optics, biotechnology, and medicine. Nanomaterials can be successfully applied to biomolecule and drug detection in plasmonic nanosensors for pharmaceutical and biomedical analysis. Plasmonic-based sensing technology exhibits high sensitivity and selectivity depending on surface plasmon resonance (SPR) or localized surface plasmon resonance (LSPR) phenomena. In this critical paper, we offer an overview of the methodology of the SPR, LSPR, surface-enhanced Raman scattering (SERS), surface-enhanced infrared absorption (SEIRA), surface-enhanced fluorescence (SEF), and plasmonic nanoplatforms advanced for pharmaceutical and biomedical applications. First of all, we present here a brief discussion of the above trends. We have devoted the last section to the explanation of SPR, LSPR, SERS, SEIRA, and SEF platforms, which have found a wide range of applications, and reviewed recent advances for biomedical and pharmaceutical analysis.
Collapse
Affiliation(s)
- Semra Akgönüllü
- Hacettepe University, Department of Chemistry, Ankara, Turkey
| | - Adil Denizli
- Hacettepe University, Department of Chemistry, Ankara, Turkey.
| |
Collapse
|
4
|
Beiki T, Najafpour-Darzi G, Mohammadi M, Shakeri M, Boukherroub R. Fabrication of a novel electrochemical biosensor based on a molecular imprinted polymer-aptamer hybrid receptor for lysozyme determination. Anal Bioanal Chem 2023; 415:899-911. [PMID: 36544030 DOI: 10.1007/s00216-022-04487-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 11/19/2022] [Accepted: 12/13/2022] [Indexed: 12/24/2022]
Abstract
In this work, a novel, sensitive, and rapid electrochemical biosensor was employed to detect lysozyme (Lys) using a double receptor of molecular imprinted polymer (MIP)-aptamer. First, a glassy carbon electrode (GCE) was modified with a nanocomposite consisting of multi-wall carbon nanotubes (MWCNTs), nitrogen-doped carbon quantum dots (N-CQDs), and chitosan. Subsequently, aptamer (Apt)-Lys complex was immobilized on MWCNTs-N-CQDs-chitosan/GCE via binding between carboxyl groups present in the nanocomposite and the terminal amine groups of the aptamer. Following that, methylene blue monomer was electrochemically polymerized around the Apt-Lys complex on the MWCNTs-N-CQDs-chitosan/GCE surface. Finally, after the template removal, the remaining cavities along with the aptamers created a new hybrid receptor of MIP-aptamer. The MWCNTs-N-CQDs-chitosan nanocomposite could provide large amounts of carboxyl groups for binding to amino-functionalized aptamers, considerable electrical conductivity, and a high surface-to-volume ratio. These beneficial features facilitated the Apt-Lys complex immobilization and gave improved electrochemical signal. The obtained MIP-aptamer hybrid receptor allowed lysozyme determination even at concentrations as low as 4.26 fM within the functional range of 1 fM to 100 nM.
Collapse
Affiliation(s)
- Tavoos Beiki
- Biotechnology Research Laboratory, Department of Chemical Engineering, Babol Noshirvani University of Technology, Babol, 47148-71167, Iran
| | - Ghasem Najafpour-Darzi
- Biotechnology Research Laboratory, Department of Chemical Engineering, Babol Noshirvani University of Technology, Babol, 47148-71167, Iran.
| | - Maedeh Mohammadi
- Biotechnology Research Laboratory, Department of Chemical Engineering, Babol Noshirvani University of Technology, Babol, 47148-71167, Iran
| | - Mohsen Shakeri
- Department of Mechanical Engineering, Babol Noshirvani University of Technology, Babol, 47148-71167, Iran
| | - Rabah Boukherroub
- Univ. Lille, CNRS, Centrale Lille, Univ. Polytechnique Hauts-de-France, UMR 8520 - IEMN, F-59000, Lille, France
| |
Collapse
|
5
|
Bahri M, Gebre SH, Elaguech MA, Dajan FT, Sendeku MG, Tlili C, Wang D. Recent advances in chemical vapour deposition techniques for graphene-based nanoarchitectures: From synthesis to contemporary applications. Coord Chem Rev 2023. [DOI: 10.1016/j.ccr.2022.214910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
6
|
Tramonti V, Lofrumento C, Martina MR, Lucchesi G, Caminati G. Graphene Oxide/Silver Nanoparticles Platforms for the Detection and Discrimination of Native and Fibrillar Lysozyme: A Combined QCM and SERS Approach. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:600. [PMID: 35214929 PMCID: PMC8878839 DOI: 10.3390/nano12040600] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 01/26/2022] [Accepted: 02/06/2022] [Indexed: 11/17/2022]
Abstract
We propose a sensing platform based on graphene oxide/silver nanoparticles arrays (GO/AgNPs) for the detection and discrimination of the native and toxic fibrillar forms of an amyloid-prone protein, lysozyme, by means of a combination of Quartz Crystal Microbalance (QCM) and Surface Enhanced Raman Scattering (SERS) measurements. The GO/AgNPs layer system was obtained by Langmuir-Blodgett assembly of the silver nanoparticles followed by controlled adsorption of GO sheets on the AgNPs array. The adsorption of native and fibrillar lysozyme was followed by means of QCM, the measurements provided the kinetics and the mechanism of adsorption as a function of protein concentration as well as the mass and thickness of the adsorbed protein on both nanoplatforms. The morphology of the protein layer was characterized by Confocal Laser Scanning Microscopy experiments on Thioflavine T-stained samples. SERS experiments performed on arrays of bare AgNPs and of GO coated AgNP after native, or fibrillar, lysozyme adsorption allowed for the discrimination of the native form and toxic fibrillar structure of lysozyme. Results from combined QCM/SERS studies indicate a general construction paradigm for an efficient sensing platform with high selectivity and low detection limit for native and amyloid lysozyme.
Collapse
Affiliation(s)
| | | | | | | | - Gabriella Caminati
- Department of Chemistry and CSGI, University of Florence, Via della Lastruccia 3-13, 50019 Sesto Fiorentino, Italy; (V.T.); (C.L.); (M.R.M.); (G.L.)
| |
Collapse
|
7
|
|
8
|
Meng F, Aihaiti A, Li X, Zhang W, Qin Y, Zhu N, Zhang M. Functional graphene paper from smart building to sensor application. Biosens Bioelectron 2022; 203:114031. [DOI: 10.1016/j.bios.2022.114031] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 01/17/2022] [Accepted: 01/20/2022] [Indexed: 11/02/2022]
|
9
|
Chen XF, Zhao X, Yang Z. Aptasensors for the detection of infectious pathogens: design strategies and point-of-care testing. Mikrochim Acta 2022; 189:443. [PMID: 36350388 PMCID: PMC9643942 DOI: 10.1007/s00604-022-05533-w] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 10/10/2022] [Indexed: 11/11/2022]
Abstract
The epidemic of infectious diseases caused by contagious pathogens is a life-threatening hazard to the entire human population worldwide. A timely and accurate diagnosis is the critical link in the fight against infectious diseases. Aptamer-based biosensors, the so-called aptasensors, employ nucleic acid aptamers as bio-receptors for the recognition of target pathogens of interest. This review focuses on the design strategies as well as state-of-the-art technologies of aptasensor-based diagnostics for infectious pathogens (mainly bacteria and viruses), covering the utilization of three major signal transducers, the employment of aptamers as recognition moieties, the construction of versatile biosensing platforms (mostly micro and nanomaterial-based), innovated reporting mechanisms, and signal enhancement approaches. Advanced point-of-care testing (POCT) for infectious disease diagnostics are also discussed highlighting some representative ready-to-use devices to address the urgent needs of currently prevalent coronavirus disease 2019 (COVID-19). Pressing issues in aptamer-based technology and some future perspectives of aptasensors are provided for the implementation of aptasensor-based diagnostics into practical application.
Collapse
Affiliation(s)
- Xiao-Fei Chen
- Guangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology, Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center, Guangzhou), Guangzhou, 510070, People's Republic of China
| | - Xin Zhao
- Guangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology, Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center, Guangzhou), Guangzhou, 510070, People's Republic of China.
| | - Zifeng Yang
- State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, People's Republic of China.
- Guangzhou Laboratory, Guangzhou, 510320, People's Republic of China.
- Guangzhou Key Laboratory for Clinical Rapid Diagnosis and Early Warning of Infectious Diseases, Guangzhou, 510005, People's Republic of China.
| |
Collapse
|
10
|
Burdanova MG, Kharlamova MV, Kramberger C, Nikitin MP. Applications of Pristine and Functionalized Carbon Nanotubes, Graphene, and Graphene Nanoribbons in Biomedicine. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:3020. [PMID: 34835783 PMCID: PMC8626004 DOI: 10.3390/nano11113020] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 10/27/2021] [Accepted: 11/02/2021] [Indexed: 12/12/2022]
Abstract
This review is dedicated to a comprehensive description of the latest achievements in the chemical functionalization routes and applications of carbon nanomaterials (CNMs), such as carbon nanotubes, graphene, and graphene nanoribbons. The review starts from the description of noncovalent and covalent exohedral modification approaches, as well as an endohedral functionalization method. After that, the methods to improve the functionalities of CNMs are highlighted. These methods include the functionalization for improving the hydrophilicity, biocompatibility, blood circulation time and tumor accumulation, and the cellular uptake and selectivity. The main part of this review includes the description of the applications of functionalized CNMs in bioimaging, drug delivery, and biosensors. Then, the toxicity studies of CNMs are highlighted. Finally, the further directions of the development of the field are presented.
Collapse
Affiliation(s)
- Maria G. Burdanova
- Center for Photonics and 2D Materials, Moscow Institute of Physics and Technology, Institutskii Pereulok 9, 141700 Dolgoprudny, Russia;
- Department of Physics, Moscow Region State University, Very Voloshinoy Street, 24, 141014 Mytishi, Russia
| | - Marianna V. Kharlamova
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Institutskii Pereulok 9, 141700 Dolgoprudny, Russia;
- Institute of Materials Chemistry, Vienna University of Technology, Getreidemarkt 9/BC/2, 1060 Vienna, Austria
| | - Christian Kramberger
- Faculty of Physics, University of Vienna, Strudlhofgasse 4, 1090 Vienna, Austria;
| | - Maxim P. Nikitin
- Phystech School of Biological and Medical Physics, Moscow Institute of Physics and Technology, Institutskii Pereulok 9, 141700 Dolgoprudny, Russia;
| |
Collapse
|
11
|
Yildiz G, Bolton-Warberg M, Awaja F. Graphene and graphene oxide for bio-sensing: General properties and the effects of graphene ripples. Acta Biomater 2021; 131:62-79. [PMID: 34237423 DOI: 10.1016/j.actbio.2021.06.047] [Citation(s) in RCA: 63] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 05/21/2021] [Accepted: 06/29/2021] [Indexed: 02/08/2023]
Abstract
The use of Graphene based materials, such as graphene oxide (GO), in biosensing applications is gaining significant interest, due to high signal output, with strong potential for high industrial growth rate. Graphene's excellent conduction and mechanical properties (such as toughness and elasticity) coupled with high reactivity to chemical molecules are some of its appealing properties. The presence of ripples on the surface (whether indigenous or induced) represents another property/variable that provide enormous potential if harnessed properly. In this article, we review the current knowledge regarding the use of graphene for biosensing. We discuss briefly the general topic of using graphene for biosensing applications with special emphasis on wearable graphene-based biosensors. The intrinsic ripples of graphene and their effect on graphene biosensing capabilities are thoroughly discussed. We dedicate a section also for the manipulation of intrinsic ripples. Then we review the use of Graphene oxide (GO) in biosensing and discuss the effect of ripples on its properties. We present a review of the current biosensor devices made out of GO for detection of different molecular targets. Finally, we present some thoughts for future perspectives and opportunities of this field. STATEMENT OF SIGNIFICANCE: Biosensors are tools that detect the presence and amount of a chemical substance, such as pregnancy tests and glucose monitoring devices. They are general portable, have short response times and are sensitive, making them highly effective. Gold and silver are used in biosensors and more recently, graphene. Graphene is sheets of carbon atoms and is the only two-dimensional crystal in nature. It has unique features allowing its effective use in biosensing applications, including the presence of ripples (non-flat areas that give it its electronic properties). The last comprehensive review of this topic was published in 2016. This paper reviews the current knowledge of graphene based biosensors, with a focus on ripples and their effect on graphene biosensing capabilities.
Collapse
|
12
|
Senturk H, Eksin E, Işık Ö, İlaslan Z, Mısırlı F, Erdem A. Impedimetric aptasensor for lysozyme detection based on carbon nanofibres enriched screen-printed electrodes. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138078] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
13
|
Melinte G, Selvolini G, Cristea C, Marrazza G. Aptasensors for lysozyme detection: Recent advances. Talanta 2021; 226:122169. [PMID: 33676711 DOI: 10.1016/j.talanta.2021.122169] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 01/26/2021] [Accepted: 01/27/2021] [Indexed: 02/06/2023]
Abstract
Lysozyme is an enzyme existing in multiple organisms where it plays various vital roles. The most important role is its antibacterial activity in the human body; in fact, it is also called "the body's own antibiotic". Despite its proven utility, lysozyme can potentially trigger allergic reactions in sensitive individuals, even in trace amounts. Therefore, lysozyme determination in foods is becoming of paramount importance. Traditional detection methods are expensive, time-consuming and they cannot be applied for fast in-situ quantification. Electrochemical and optical sensors have attracted an increasing attention due to their versatility and ability to reduce the disadvantages of traditional methods. Using an aptamer as the bioreceptor, the sensor selectivity is amplified due to the specific recognition of the analyte. This review is presenting the progresses made in lysozyme determination by means of electrochemical and optical aptasensors in the last five years. A critical overview on the methodologies employed for aptamer immobilization and on the strategies for signal amplification of the assays will be described. Different optical and electrochemical aptasensors will be discussed and compared in terms of analytical performances, versatility and real samples applications.
Collapse
Affiliation(s)
- Gheorghe Melinte
- "Ugo Schiff" Chemistry Department, University of Florence, Via della Lastruccia 3, Sesto Fiorentino (FI), 50019, Italy; Analytical Chemistry Department, Faculty of Pharmacy, "Iuliu Hatieganu" University of Medicine and Pharmacy, Strada Louis Pasteur 4, Cluj-Napoca, 400349, Romania
| | - Giulia Selvolini
- "Ugo Schiff" Chemistry Department, University of Florence, Via della Lastruccia 3, Sesto Fiorentino (FI), 50019, Italy
| | - Cecilia Cristea
- Analytical Chemistry Department, Faculty of Pharmacy, "Iuliu Hatieganu" University of Medicine and Pharmacy, Strada Louis Pasteur 4, Cluj-Napoca, 400349, Romania.
| | - Giovanna Marrazza
- "Ugo Schiff" Chemistry Department, University of Florence, Via della Lastruccia 3, Sesto Fiorentino (FI), 50019, Italy; Istituto Nazionale Biostrutture e Biosistemi (INBB), Unit of Florence, Viale Delle Medaglie D'Oro 305, 00136 Roma, Italy.
| |
Collapse
|
14
|
Sonaimuthu M, Nerthigan Y, Swaminathan N, Sharma N, Wu HF. Photoluminescent hydrophilic cyclodextrin-stabilized cysteine-protected copper nanoclusters for detecting lysozyme. Anal Bioanal Chem 2020; 412:7141-7154. [PMID: 32876723 DOI: 10.1007/s00216-020-02847-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 07/10/2020] [Accepted: 07/27/2020] [Indexed: 02/04/2023]
Abstract
Lysozyme (LYZ) sensors have attracted increased attention because rapid and sensitive detection of LYZ is highly desirable for various diseases associated with humans. In this research, we designed L-cysteine-protected ultra small photoluminescent (PL) copper nanoclusters (CuNCs) conjugated with β-cyclodextrin (β-CD) for rapid detection of LYZ in human serum samples at room temperature. The proposed β-CD-CuNCs exhibited excellent water solubility, ultrafine size, good dispersion, bright photoluminescence, and good photostability. The β-CD-CuNCs exhibit an excitation and emission maximum at 370 nm and 492 nm, respectively, with an absolute quantum yield (QY) of 54.6%. β-CD-CuNCs showed a fluorescence lifetime of 12.7 ns. The addition of LYZ would result in PL quenching from β-CD-CuNCs. The lowest detectable LYZ concentration was 50 nM for the naked eye and the limit of detection (LOD) and limit of quantification (LOQ) were 0.36 nM and 1.21 nM, respectively, by emission measurement observed in the LYZ concentration range from 30 to 100 nM. It is important to note that the PL β-CD-CuNC strategy possessed great selectivity toward LYZ relative to other biomolecules. The proposed nanosensor was efficiently applied to determine the LYZ level in human serum sample average recoveries from 96.15 to 104.05% and relative standard deviation (RSD) values lower than 3.0%. Moreover, the proposed sensing system showed many advantages, including high speed, high sensitivity, high selectivity, low cost, and simple preparation.
Collapse
Affiliation(s)
- Mohandoss Sonaimuthu
- Department of Chemistry, National Sun Yat-Sen University, 70, Lien-Hai Road, Kaohsiung, 80424, Taiwan
| | - Yowan Nerthigan
- Department of Chemistry, National Sun Yat-Sen University, 70, Lien-Hai Road, Kaohsiung, 80424, Taiwan
| | - Nandini Swaminathan
- Department of Chemistry, National Sun Yat-Sen University, 70, Lien-Hai Road, Kaohsiung, 80424, Taiwan
| | - Nallin Sharma
- Department of Chemistry, National Sun Yat-Sen University, 70, Lien-Hai Road, Kaohsiung, 80424, Taiwan
| | - Hui-Fen Wu
- Department of Chemistry, National Sun Yat-Sen University, 70, Lien-Hai Road, Kaohsiung, 80424, Taiwan. .,School of Pharmacy, College of Pharmacy, Kaohsiung Medical University, Kaohsiung, 807, Taiwan. .,International PhD program for Science, National Sun Yat-sen University, 70 Lien-hai Road, Kaohsiung, 80424, Taiwan. .,Institute of Medical Science and Technology, National Sun Yat-Sen University, Kaohsiung, 80424, Taiwan.
| |
Collapse
|
15
|
FRET-Based Aptasensor for the Selective and Sensitive Detection of Lysozyme. SENSORS 2020; 20:s20030914. [PMID: 32050422 PMCID: PMC7038949 DOI: 10.3390/s20030914] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 02/03/2020] [Accepted: 02/05/2020] [Indexed: 12/12/2022]
Abstract
Lysozyme is a conserved antimicrobial enzyme and has been cited for its role in immune modulation. Increase in lysozyme concentration in body fluids is also regarded as an early warning of some diseases such as Alzheimer’s, sarcoidosis, Crohn’s disease, and breast cancer. Therefore, a method for a sensitive and selective detection of lysozyme can benefit many different areas of research. In this regard, several aptamers that are specific to lysozyme have been developed, but there is still a lack of a detection method that is sensitive, specific, and quantitative. In this work, we demonstrated a single-molecule fluorescence resonance energy transfer (smFRET)-based detection of lysozyme using an aptamer sensor (also called aptasensor) in which the binding of lysozyme triggers its conformational switch from a low-FRET to high-FRET state. Using this strategy, we demonstrated that the aptasensor is sensitive down to 2.3 picomoles (30 nM) of lysozyme with a dynamic range extending to ~2 µM and has little to no interference from similar biomolecules. The smFRET approach used here requires a dramatically small amount of aptasensor (~3000-fold less as compared to typical bulk fluorescence methods), and it is cost effective compared to enzymatic and antibody-based approaches. Additionally, the aptasensor can be readily regenerated in situ via a process called toehold mediated strand displacement (TMSD). The FRET-based aptasensing of lysozyme that we developed here could be implemented to detect other protein biomarkers by incorporating protein-specific aptamers without the need for changing fluorophore-labeled DNA strands.
Collapse
|
16
|
Graphene-Based Biosensors for Detection of Biomarkers. MICROMACHINES 2020; 11:mi11010060. [PMID: 31947894 PMCID: PMC7019259 DOI: 10.3390/mi11010060] [Citation(s) in RCA: 82] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 12/23/2019] [Accepted: 12/30/2019] [Indexed: 12/16/2022]
Abstract
The development of biosensors with high sensitivity and low-detection limits provides a new direction for medical and personal care. Graphene and graphene derivatives have been used to prepare various types of biosensors due to their excellent sensing performance (e.g., high specific surface area, extraordinary electronic properties, electron transport capabilities and ultrahigh flexibility). This perspective review focuses on graphene-based biosensors for quantitative detection of cancer-related biomarkers such as DNA, miRNA, small molecules and proteins by integrating with different signal outputting approaches including fluorescent, electrochemistry, surface plasmon resonance, surface enhanced Raman scattering, etc. The article also discussed their challenges and potential solutions along with future prospects.
Collapse
|
17
|
Shahdeo D, Roberts A, Abbineni N, Gandhi S. Graphene based sensors. ANALYTICAL APPLICATIONS OF GRAPHENE FOR COMPREHENSIVE ANALYTICAL CHEMISTRY 2020. [PMCID: PMC7518956 DOI: 10.1016/bs.coac.2020.08.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
The two dimensional, honeycomb structured, single carbon layered graphene has extensively been used in the field of sensor detection due to its unique physicochemical properties. These properties such as excellent electrical conductivity, high electron mobility, tunable optical properties, room temperature quantum Hall effect, large surface to volume ratio, high mechanical strength, and ease of functionalization, make it an ideal nanomaterial for sensor development. This has enabled the fabrication of a large variety of highly sensitive sensors which include colorimetric, electrochemical, potentiometric, fluorescence, etc. based sensors. These sensors in conjugation with graphene or its derivatives such as graphene quantum dots, graphene oxide, reduced graphene oxide, etc. show highly desirable properties such as high sensitivity (detecting minute amounts of target analyte), specificity (no cross reactivity while detecting the target analyte), rapid results, low cost, extended storage shelf life and robustness (stability), and easy-to-use capabilities (user-friendly). This book chapter gives a detailed overview of all the advances made in the development and fabrication of novel graphene based sensors and their application in point of care (PoC) detection of various diseases as well as health monitoring devices. The different sensors, their methods of fabrication, their sensitivity and the analytes and biomolecules used have been discussed in detail and compared.
Collapse
|
18
|
Fatema KN, Oh WC. A Comprehensive Review: Development of Biosensors Based on
Graphene-Mesoporous Combined Materials. ACTA ACUST UNITED AC 2019. [DOI: 10.14233/ajmc.2019.ajmc-p76] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Reliable data obtained from analysis of DNA, proteins, bacteria and other disease-related molecules or organisms in biological samples have become a fundamental and crucial part of human health diagnostics and therapy. After a brief summary of the implication of template based ordered mesoporous materials in electrochemical science, the various types of inorganic and organic-inorganic hybrid mesostructured used to date in electroanalysis and the corresponding electrode configurations are
described. The development of non-invasive tests that are rapid, sensitive, specific and simple would allow patient discomfort to be prevented, delays in diagnosis to be avoided and the status of a disease to be followed up. The use of biosensors for the early diagnosis of diseases has become widely accepted as a point-of-care diagnosis with appropriate specificity in a short time. To allow a reliable diagnosis of a disease at an early stage, highly sensitive biosensors are required as the corresponding biomarkers are generally expressed at very low concentrations. In past 50 years, various biosensors have been researched and developed encompassing a wide range of applications. This contrasts the limited number of commercially available biosensors. Lately, graphene-based materials have been considered as superior over other nanomaterials for the development of sensitive biosensors. The advantages of graphenebased sensor interfaces are numerous, including enhanced surface loading of desired ligand due to the high surface-to-volume ratio, excellent conductivity and a small band gap that is beneficial for sensitive electrical and electrochemical read-outs, as well as tunable optical properties for optical read-outs such as fluorescence and plasmonics. In this paper, we review the advances made in recent years on graphenebased biosensors in the field of medical diagnosis.
Collapse
Affiliation(s)
- Kamrun Nahar Fatema
- Department of Advanced Materials Science & Engineering, Hanseo University, Seosan-si, Chungnam 356-706, Republic of Korea
| | - Won-Chun Oh
- Department of Advanced Materials Science & Engineering, Hanseo University, Seosan-si, Chungnam 356-706, Republic of Korea
| |
Collapse
|
19
|
Patil PO, Pandey GR, Patil AG, Borse VB, Deshmukh PK, Patil DR, Tade RS, Nangare SN, Khan ZG, Patil AM, More MP, Veerapandian M, Bari SB. Graphene-based nanocomposites for sensitivity enhancement of surface plasmon resonance sensor for biological and chemical sensing: A review. Biosens Bioelectron 2019; 139:111324. [PMID: 31121435 DOI: 10.1016/j.bios.2019.111324] [Citation(s) in RCA: 93] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2019] [Revised: 05/01/2019] [Accepted: 05/12/2019] [Indexed: 02/07/2023]
Abstract
Surface plasmon resonance (SPR) offers exceptional advantages such as label-free, in-situ and real-time measurement ability that facilitates the study of molecular or chemical binding events. Besides, SPR lacks in the detection of various binding events, particularly involving low molecular weight molecules. This drawback ultimately resulted in the development of several sensitivity enhancement methodologies and their application in the various area. Among graphene materials, graphene-based nanocomposites stands out owing to its significant properties such as strong adsorption of molecules, signal amplification by optical, high carrier mobility, electronic bridging, ease of fabrication and therefore, have established as an important sensitivity enhancement substrate for SPR. Also, graphene-based nanocomposites could amplify the signal generated by plasmon material and increase the sensitivity of molecular detection up to femto to atto molar level. This review focuses on the current important developments made in the potential research avenue of SPR and fiber optics based SPR for chemical and biological sensing. Latest trends and challenges in engineering and applications of graphene-based nanocomposites enhanced sensors for detecting minute and low concentration biological and chemical analytes are reviewed comprehensively. This review may aid in futuristic designing approaches and application of grapheneous sensor platforms for sensitive plasmonic nano-sensors.
Collapse
Affiliation(s)
- Pravin O Patil
- H. R. Patel Institute of Pharmaceutical Education and Research, Shirpur, 425405, Maharashtra, India.
| | - Gaurav R Pandey
- H. R. Patel Institute of Pharmaceutical Education and Research, Shirpur, 425405, Maharashtra, India
| | - Ashwini G Patil
- R. C. Patel Arts, Science and Commerce College, Shirpur, 425405, Maharashtra, India
| | - Vivek B Borse
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, Guwahati, 781039, Assam, India
| | - Prashant K Deshmukh
- H. R. Patel Institute of Pharmaceutical Education and Research, Shirpur, 425405, Maharashtra, India
| | - Dilip R Patil
- R. C. Patel Arts, Science and Commerce College, Shirpur, 425405, Maharashtra, India
| | - Rahul S Tade
- H. R. Patel Institute of Pharmaceutical Education and Research, Shirpur, 425405, Maharashtra, India
| | - Sopan N Nangare
- H. R. Patel Institute of Pharmaceutical Education and Research, Shirpur, 425405, Maharashtra, India
| | - Zamir G Khan
- H. R. Patel Institute of Pharmaceutical Education and Research, Shirpur, 425405, Maharashtra, India
| | - Arun M Patil
- R. C. Patel Arts, Science and Commerce College, Shirpur, 425405, Maharashtra, India
| | - Mahesh P More
- H. R. Patel Institute of Pharmaceutical Education and Research, Shirpur, 425405, Maharashtra, India
| | - Murugan Veerapandian
- Council of Scientific and Industrial Research-Central Electrochemical Research Institute, Karaikudi-630003, Tamilnadu, India
| | - Sanjay B Bari
- H. R. Patel Institute of Pharmaceutical Education and Research, Shirpur, 425405, Maharashtra, India
| |
Collapse
|
20
|
Almohammed S, Zhang F, Rodriguez BJ, Rice JH. Electric Field-Induced Chemical Surface-Enhanced Raman Spectroscopy Enhancement from Aligned Peptide Nanotube-Graphene Oxide Templates for Universal Trace Detection of Biomolecules. J Phys Chem Lett 2019; 10:1878-1887. [PMID: 30925050 DOI: 10.1021/acs.jpclett.9b00436] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Semiconductor-graphene oxide-based surface-enhanced Raman spectroscopy substrates represent a new frontier in the field of surface-enhanced Raman spectroscopy (SERS). However, the application of graphene oxide has had limited success because of the poor Raman enhancement factors that are achievable in comparison to noble metals. In this work, we report chemical SERS enhancement enabled by the application of an electric field (10-25 V/mm) to aligned semiconducting peptide nanotube-graphene oxide composite structures during Raman measurements. The technique enables nanomolar detection sensitivity of glucose and nucleobases with up to 10-fold signal enhancement compared to metal-based substrates, which, to our knowledge, is higher than that previously reported for semiconductor-based SERS substrates. The increased Raman scattering is assigned to enhanced charge-transfer resonance enabled by work function lowering of the peptide nanotubes. These results provide insight into how semiconductor organic peptide nanotubes interact with graphene oxide, which may facilitate chemical biosensing, electronic devices, and energy-harvesting applications.
Collapse
Affiliation(s)
- Sawsan Almohammed
- School of Physics , University College Dublin , Belfield , Dublin 4 , Ireland
- Conway Institute of Biomolecular and Biomedical Research , University College Dublin , Belfield , Dublin 4 , Ireland
| | - Fengyuan Zhang
- School of Physics , University College Dublin , Belfield , Dublin 4 , Ireland
- Conway Institute of Biomolecular and Biomedical Research , University College Dublin , Belfield , Dublin 4 , Ireland
| | - Brian J Rodriguez
- School of Physics , University College Dublin , Belfield , Dublin 4 , Ireland
- Conway Institute of Biomolecular and Biomedical Research , University College Dublin , Belfield , Dublin 4 , Ireland
| | - James H Rice
- School of Physics , University College Dublin , Belfield , Dublin 4 , Ireland
| |
Collapse
|
21
|
Farcau C. Metal-coated microsphere monolayers as surface plasmon resonance sensors operating in both transmission and reflection modes. Sci Rep 2019; 9:3683. [PMID: 30842522 PMCID: PMC6403218 DOI: 10.1038/s41598-019-40261-x] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2018] [Accepted: 02/11/2019] [Indexed: 11/26/2022] Open
Abstract
Metal-coated microsphere monolayers (MCM) are a class of plasmonic crystals consisting of noble metal films over arrays of self-assembled colloidal microspheres. Despite their ease of fabrication and tunable plasmonic response, their optical sensing potential has been scarcely explored. Here, silver coated polystyrene sphere monolayers are proposed as surface plasmon resonance sensors capable of functioning in both transmission (T) and reflection (R) readout modes. An original and key point is the use of ~200 nm colloids, smaller than in MCM studied before. It allowed us to reveal a previously unobserved, additional/secondary Enhanced Optical Transmission band, which can be exploited in sensing, with higher sensitivity than the better-known main transmission band. The reflection configuration however, is almost an order of magnitude more efficient for sensing than the transmission one. We also evidenced a strong impact of the adsorbate location on the metal surface on the sensing efficiency. Electric field distribution analysis is performed to explain these results. Proof-of-concept experiments on the detection of 11-MUA molecular monolayers, performed in both readout modes, confirm the behaviors observed through FDTD simulations. Results in this paper can serve as guidelines for designing optimized sensors based on metal-coated colloidal monolayers, and more generally for plasmonic sensors based on metal nanostructured films.
Collapse
Affiliation(s)
- Cosmin Farcau
- National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Str., 400293, Cluj-Napoca, Romania. .,Institute for Interdisciplinary Research in Bio-Nano-Sciences, Babes-Bolyai University, 42 T. Laurian, 400271, Cluj-Napoca, Romania.
| |
Collapse
|
22
|
Fu F, Li L, Luo Q, Li Q, Guo T, Yu M, Song Y, Song E. Selective and sensitive detection of lysozyme based on plasmon resonance light-scattering of hydrolyzed peptidoglycan stabilized-gold nanoparticles. Analyst 2019; 143:1133-1140. [PMID: 29392248 DOI: 10.1039/c7an01570d] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
The simple, economic, rapid, and sensitive detection of lysozyme has an important significance for disease diagnosis since it is a potential biomarker. In this work, a new detection strategy for lysozyme was developed based on the change of the plasmon resonance light scattering (PRLS) signal of peptidoglycan stabilized gold nanoparticles (PGN-AuNPs). Peptidoglycan (PGN) was employed as a stabilizer to prepare PGN-AuNPs which have the properties of a uniform particle size, good stability, and a specific biological function. Due to the specific cleavage of lysozyme to PGN, a very simple specific and sensitive detection method for lysozyme was developed based on the PRLS signal of PGN-AuNPs after mixing with lysozyme for 1.5 h. The enhanced PRLS signals (ΔIPRLS, at 560 nm) increased linearly with increasing lysozyme in the range 5 nM to 1600 nM with the detection limit down to 2.32 nM (ΔIPRLS = 41.6397 + 0.5332c, R = 0.9961). When the PGN-AuNP based method was applied to assay lysozyme in authentic human serum samples, the recovery efficiency was 106.76-119.32% with the relative standard deviations in the range of 0.14-3.11%, showing good feasibility. The PGN-AuNP based method for lysozyme assay developed here is simple, rapid, selective, and sensitive, which is expected to provide a feasible new method for the diagnosis or prognosis of lysozyme-related diseases in a clinical setting.
Collapse
Affiliation(s)
- Fei Fu
- Key Laboratory of Luminescence and Real-Time Analytical Chemistry, Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing, 400715, China.
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Dual-functional polymer-modified magnetic nanoparticles for isolation of lysozyme. Anal Chim Acta 2018; 1035:70-76. [DOI: 10.1016/j.aca.2018.07.019] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2018] [Revised: 06/13/2018] [Accepted: 07/07/2018] [Indexed: 12/30/2022]
|
24
|
Primo EN, Kogan MJ, Verdejo HE, Bollo S, Rubianes MD, Rivas GA. Label-Free Graphene Oxide-Based Surface Plasmon Resonance Immunosensor for the Quantification of Galectin-3, a Novel Cardiac Biomarker. ACS APPLIED MATERIALS & INTERFACES 2018; 10:23501-23508. [PMID: 29985579 DOI: 10.1021/acsami.8b03039] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
We report the first optical biosensor for the novel and important cardiac biomarker, galectin-3 (Gal3), using the anti-Gal3 antibody as a biorecognition element and surface plasmon resonance (SPR) for transducing the bioaffinity event. The immunosensing platform was built at a thiolated Au surface modified by self-assembling four bilayers of poly(diallyldimethylammonium chloride) and graphene oxide (GO), followed by the covalent attachment of 3-aminephenylboronic acid (3ABA). The importance of GO, both as the anchoring point of the antibody and as a field enhancer for improving the biosensor sensitivity, was critically discussed. The advantages of using 3ABA to orientate the anti-Gal3 antibody through the selective link to the Fc region were also demonstrated. The new platform represents an interesting alternative for the label-free biosensing of Gal3 in the whole range of clinically relevant concentrations (linear range between 10.0 and 50.0 ng mL-1, detection limit of 2.0 ng mL-1) with successful application for Gal3 biosensing in enriched human serum samples.
Collapse
Affiliation(s)
- Emiliano N Primo
- INFIQC (CONICET), Haya de la Torre s/n, Ciudad Universitaria , X5000HUA Córdoba , Argentina
- Departamento de Fisicoquímica, Facultad de Ciencias Químicas , Universidad Nacional de Córdoba, Ciudad Universitaria , X5000HUA Córdoba , Argentina
| | - Marcelo J Kogan
- Advanced Center for Chronic Diseases (ACCDiS), Facultad de Ciencias Químicas y Farmacéuticas, Departamento de Química Farmacológica y Toxicológica , Universidad de Chile , 8380492 Santiago , Chile
| | - Hugo E Verdejo
- Advanced Center for Chronic Diseases (ACCDiS), División de Enfermedades Cardiovasculares, Facultad de Medicina , Pontificia Universidad Católica de Chile , 7500011 Santiago , Chile
| | - Soledad Bollo
- Advanced Center for Chronic Diseases (ACCDiS), Facultad de Ciencias Químicas y Farmacéuticas, Departamento de Química Farmacológica y Toxicológica , Universidad de Chile , 8380492 Santiago , Chile
| | - María D Rubianes
- INFIQC (CONICET), Haya de la Torre s/n, Ciudad Universitaria , X5000HUA Córdoba , Argentina
- Departamento de Fisicoquímica, Facultad de Ciencias Químicas , Universidad Nacional de Córdoba, Ciudad Universitaria , X5000HUA Córdoba , Argentina
| | - Gustavo A Rivas
- INFIQC (CONICET), Haya de la Torre s/n, Ciudad Universitaria , X5000HUA Córdoba , Argentina
- Departamento de Fisicoquímica, Facultad de Ciencias Químicas , Universidad Nacional de Córdoba, Ciudad Universitaria , X5000HUA Córdoba , Argentina
| |
Collapse
|
25
|
Abstract
Reliable data obtained from analysis of DNA, proteins, bacteria and other disease-related molecules or organisms in biological samples have become a fundamental and crucial part of human health diagnostics and therapy. The development of non-invasive tests that are rapid, sensitive, specific and simple would allow patient discomfort to be prevented, delays in diagnosis to be avoided and the status of a disease to be followed up. Bioanalysis is thus a progressive discipline for which the future holds many exciting opportunities. The use of biosensors for the early diagnosis of diseases has become widely accepted as a point-of-care diagnosis with appropriate specificity in a short time. To allow a reliable diagnosis of a disease at an early stage, highly sensitive biosensors are required as the corresponding biomarkers are generally expressed at very low concentrations. In the past 50 years, various biosensors have been researched and developed encompassing a wide range of applications. This contrasts the limited number of commercially available biosensors. When it comes to sensing of biomarkers with the required picomolar (pM) sensitivity for real-time sensing of biological samples, only a handful of sensing systems have been proposed, and these are often rather complex and costly. Lately, graphene-based materials have been considered as superior over other nanomaterials for the development of sensitive biosensors. The advantages of graphene-based sensor interfaces are numerous, including enhanced surface loading of the desired ligand due to the high surface-to-volume ratio, excellent conductivity and a small band gap that is beneficial for sensitive electrical and electrochemical read-outs, as well as tunable optical properties for optical read-outs such as fluorescence and plasmonics. In this paper, we review the advances made in recent years on graphene-based biosensors in the field of medical diagnosis.
Collapse
Affiliation(s)
- Sabine Szunerits
- Université de Lille, CNRS, Centrale Lille, ISEN, Université de Valenciennes, UMR 8520-IEMN, 59000 Lille, France
| | | |
Collapse
|
26
|
Zhang C, Parrello D, Brown PJB, Wall JD, Hu Z. A novel whole-cell biosensor of Pseudomonas aeruginosa to monitor the expression of quorum sensing genes. Appl Microbiol Biotechnol 2018; 102:6023-6038. [PMID: 29730766 DOI: 10.1007/s00253-018-9044-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 04/19/2018] [Accepted: 04/19/2018] [Indexed: 01/01/2023]
Abstract
A novel whole-cell biosensor was developed to noninvasively and simultaneously monitor the in situ genetic activities of the four quorum sensing (QS) networks in Pseudomonas aeruginosa PAO1, including the las, rhl, pqs, and iqs systems. P. aeruginosa PAO1 is a model bacterium for studies of biofilm and pathogenesis while both processes are closely controlled by the QS systems. This biosensor worked well by selectively monitoring the expression of one representative gene from each network. In the biosensor, the promoter regions of lasI, rhlI, pqsA, and ambB (QS genes) controlled the fluorescent reporter genes of Turbo YFP, mTag BFP2, mNEON Green, and E2-Orange, respectively. The biosensor was successful in monitoring the impact of an important environmental factor, salt stress, on the genetic regulation of QS networks. High salt concentrations (≥ 20 g·L-1) significantly downregulated rhlI, pqsA, and ambB after the biosensor was incubated for 17 h to 18 h at 37 °C, resulting in slow bacterial growth.
Collapse
Affiliation(s)
- Chiqian Zhang
- Department of Civil & Environmental Engineering, University of Missouri, Columbia, MO, USA
| | - Damien Parrello
- Department of Civil & Environmental Engineering, University of Missouri, Columbia, MO, USA
| | - Pamela J B Brown
- Division of Biological Sciences, University of Missouri, Columbia, MO, USA
| | - Judy D Wall
- Department of Biochemistry, University of Missouri, Columbia, MO, USA
| | - Zhiqiang Hu
- Department of Civil & Environmental Engineering, University of Missouri, Columbia, MO, USA.
| |
Collapse
|
27
|
Chen D, Mei Y, Hu W, Li CM. Electrochemically enhanced antibody immobilization on polydopamine thin film for sensitive surface plasmon resonance immunoassay. Talanta 2018; 182:470-475. [DOI: 10.1016/j.talanta.2018.02.038] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 02/02/2018] [Accepted: 02/08/2018] [Indexed: 12/31/2022]
|
28
|
Vasilescu A, Ye R, Boulahneche S, Lamraoui S, Jijie R, Medjram MS, Gáspár S, Singh SK, Kurungot S, Melinte S, Boukherroub R, Szunerits S. Porous reduced graphene oxide modified electrodes for the analysis of protein aggregation. Part 2: Application to the analysis of calcitonin containing pharmaceutical formulation. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.02.038] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
29
|
Giuffrida MC, Cigliana G, Spoto G. Ultrasensitive detection of lysozyme in droplet-based microfluidic devices. Biosens Bioelectron 2017; 104:8-14. [PMID: 29294408 DOI: 10.1016/j.bios.2017.12.042] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Revised: 12/20/2017] [Accepted: 12/26/2017] [Indexed: 12/27/2022]
Abstract
Lysozyme (LYS) is a bacteriolytic enzyme, available in secretions such as saliva, tears and human milk. LYS is an important defence molecule of the innate immune system, and its overexpression can be a consequence of diseases such as leukemia, kidney disease and sarcoidosis. This paper reports on a digital microfluidic-based approach that combines the gold nanoparticle-enhanced chemiluminescence with aptamer interaction to detect human lysozyme into droplets 20 nanoliters in volume. The described method allows identifying LYS with a 44.6 femtomolar limit of detection, using sample volume as low as 1μL and detection time in the range of 10min. We used luminol to generate the chemiluminescence and demonstrated that the compartmentalization of LYS in droplets also comprising gold nanoparticles provided enhanced luminescence. We functionalized the gold nanoparticles with a thiolated aptamer to achieve the required selectivity that allowed us to detect LYS in human serum.
Collapse
Affiliation(s)
- Maria Chiara Giuffrida
- Consorzio Interuniversitario "Istituto Nazionale Biostrutture e Biosistemi", c/o Dipartimento di Scienze Chimiche, Università di Catania, Viale Andrea Doria 6, Catania, Italy
| | - Giovanni Cigliana
- Clinical Pathology Unit, Regina Elena National Cancer Institute, Via Chianesi, Roma, Italy
| | - Giuseppe Spoto
- Consorzio Interuniversitario "Istituto Nazionale Biostrutture e Biosistemi", c/o Dipartimento di Scienze Chimiche, Università di Catania, Viale Andrea Doria 6, Catania, Italy; Dipartimento di Scienze Chimiche, Università di Catania, Viale Andrea Doria 6, I-95125 Catania, Italy.
| |
Collapse
|
30
|
Dinca V, Zaharie-Butucel D, Stanica L, Brajnicov S, Marascu V, Bonciu A, Cristocea A, Gaman L, Gheorghiu M, Astilean S, Vasilescu A. Functional Micrococcus lysodeikticus layers deposited by laser technique for the optical sensing of lysozyme. Colloids Surf B Biointerfaces 2017; 162:98-107. [PMID: 29190474 DOI: 10.1016/j.colsurfb.2017.11.058] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Revised: 11/13/2017] [Accepted: 11/22/2017] [Indexed: 12/17/2022]
Abstract
Whole cell optical biosensors, made by immobilizing whole algal, bacterial or mammalian cells on various supports have found applications in several fields, from ecology and ecotoxicity testing to biopharmaceutical production or medical diagnostics. We hereby report the deposition of functional bacterial layers of Micrococcus lysodeikticus (ML) via Matrix-Assisted Pulsed Laser Evaporation (MAPLE) on poly(diallyldimethylamonium) (PDDA)-coated-glass slides and their application as an optical biosensor for the detection of lysozyme in serum. Lysozyme is an enzyme upregulated in inflammatory diseases and ML is an enzymatic substrate for this enzyme. The MAPLE-deposited bacterial interfaces were characterised by Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), Fourier-Transformed Infrared Spectroscopy (FTIR), Raman and optical microscopy and were compared with control interfaces deposited via layer-by-layer on the same substrate. After MAPLE deposition and coating with graphene oxide (GO), ML-modified interfaces retained their functionality and sensitivity to lysozyme's lytic action. The optical biosensor detected lysozyme in undiluted serum in the clinically relevant range up to 10μgmL-1, in a fast and simple manner.
Collapse
Affiliation(s)
- Valentina Dinca
- National Institute for Laser, Plasma and Radiation Physics (INFLPR), 409 Atomistilor, 077125, Magurele, Romania
| | - Diana Zaharie-Butucel
- Nanobiophotonics Center, Interdisciplinary Research Institute in Bio-Nano-Sciences, 42 Treboniu Laurian, Cluj-Napoca, Romania
| | - Luciana Stanica
- International Centre of Biodynamics, 1B Intrarea Portocalelor, 060101, Bucharest, Romania
| | - Simona Brajnicov
- National Institute for Laser, Plasma and Radiation Physics (INFLPR), 409 Atomistilor, 077125, Magurele, Romania; University of Craiova, Faculty of Mathematics and Natural Science, 13 Alexandru Ioan Cuza, 200585, Craiova, Romania
| | - Valentina Marascu
- National Institute for Laser, Plasma and Radiation Physics (INFLPR), 409 Atomistilor, 077125, Magurele, Romania; University of Bucharest, Faculty of Physics, 405 Atomistilor, 077125, Magurele, Romania
| | - Anca Bonciu
- National Institute for Laser, Plasma and Radiation Physics (INFLPR), 409 Atomistilor, 077125, Magurele, Romania; University of Bucharest, Faculty of Physics, 405 Atomistilor, 077125, Magurele, Romania
| | - Andra Cristocea
- Fundeni Clinical Institute, Department of Gastroenterology and Hepatology, 258 Sos. Fundeni, Bucharest, Romania
| | - Laura Gaman
- "Carol Davila" University of Medicine and Pharmacy, Faculty of Medicine, Department of Biochemistry, 8 B-dul Eroilor Sanitari, 76241, Bucharest, Romania
| | - Mihaela Gheorghiu
- International Centre of Biodynamics, 1B Intrarea Portocalelor, 060101, Bucharest, Romania
| | - Simion Astilean
- Nanobiophotonics Center, Interdisciplinary Research Institute in Bio-Nano-Sciences, 42 Treboniu Laurian, Cluj-Napoca, Romania
| | - Alina Vasilescu
- International Centre of Biodynamics, 1B Intrarea Portocalelor, 060101, Bucharest, Romania.
| |
Collapse
|
31
|
Suvarnaphaet P, Pechprasarn S. Graphene-Based Materials for Biosensors: A Review. SENSORS (BASEL, SWITZERLAND) 2017; 17:E2161. [PMID: 28934118 PMCID: PMC5677231 DOI: 10.3390/s17102161] [Citation(s) in RCA: 201] [Impact Index Per Article: 25.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Revised: 09/12/2017] [Accepted: 09/16/2017] [Indexed: 02/07/2023]
Abstract
The advantages conferred by the physical, optical and electrochemical properties of graphene-based nanomaterials have contributed to the current variety of ultrasensitive and selective biosensor devices. In this review, we present the points of view on the intrinsic properties of graphene and its surface engineering concerned with the transduction mechanisms in biosensing applications. We explain practical synthesis techniques along with prospective properties of the graphene-based materials, which include the pristine graphene and functionalized graphene (i.e., graphene oxide (GO), reduced graphene oxide (RGO) and graphene quantum dot (GQD). The biosensing mechanisms based on the utilization of the charge interactions with biomolecules and/or nanoparticle interactions and sensing platforms are also discussed, and the importance of surface functionalization in recent up-to-date biosensors for biological and medical applications.
Collapse
Affiliation(s)
- Phitsini Suvarnaphaet
- Faculty of Biomedical Engineering, Rangsit University, Pathum Thani 12000, Thailand.
| | - Suejit Pechprasarn
- Faculty of Biomedical Engineering, Rangsit University, Pathum Thani 12000, Thailand.
| |
Collapse
|
32
|
Abstract
Leukemia is a cancer of blood cells and bone marrow, leading to death in many patients mainly in children. Over the last several years, aptamers generated by SELEX (Systematic evolution of ligands by exponential enrichment) method, have quickly become a new class of targeting ligands for drug delivery applications and recently have been widely exploited in different biomedical applications, due to several potent properties such as high binding affinity and selectivity, low or no immunogenicity and toxicity, low cost and thermal stability. In this review, we presented in details about aptamers involved in targeting, and treatment of leukemia. Moreover, some analytical approaches such as electrochemical and optical aptasensors were introduced for detection and diagnosis of leukemia. Finally, we discussed about the directions and challenges of aptamer application in this field.
Collapse
|
33
|
Wang Q, Vasilescu A, Wang Q, Coffinier Y, Li M, Boukherroub R, Szunerits S. Electrophoretic Approach for the Simultaneous Deposition and Functionalization of Reduced Graphene Oxide Nanosheets with Diazonium Compounds: Application for Lysozyme Sensing in Serum. ACS APPLIED MATERIALS & INTERFACES 2017; 9:12823-12831. [PMID: 28323404 DOI: 10.1021/acsami.6b15955] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Electrophoretic deposition (EPD) of reduced graphene oxide nanosheets (rGO) offers several advantages over other surface coating approaches, including process simplicity, uniformity of the deposited films, and good control of the film thickness. The EPD conditions might also be of interest for the reduction of diazonium salts, which upon the release of N2 molecules and generation of radicals, can form covalent bonds with the sp2 hybridized carbon lattice atoms of rGO films. In this work, we report on the coating of gold electrodes in one step with rGO/polyethylenimine (PEI) thin films and their simultaneous modification using different phenyl (Ph) diazonium salt precursors bearing various functionalities such as -B(OH)2, -COOH, and -C≡CH. We show further the interest of such interfaces for designing highly sensitive sensing platforms. Azide-terminated lysozyme aptamers were clicked onto the rGO/PEI/Ph-alkynyl matrix and used for the sensing of lysozyme levels in patients suffering from inflammatory bowel disease (IBD), where lysozyme levels are up-regulated. The approach attained the required demand for the determination of lysozyme level in patients suffering from IBD with a 200 fM detection limit and a linear range up to 20 pM without signal amplification.
Collapse
Affiliation(s)
- Qian Wang
- Univ. Lille, CNRS, Centrale Lille, ISEN, Univ. Valenciennes, UMR 8520-IEMN , F-59000 Lille, France
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), Shandong University , Jinan 250061, China
| | - Alina Vasilescu
- International Center of Biodynamics , 1B Intrarea Portocalelor, Sector 6, 060101, Bucharest, Romania
| | - Qi Wang
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), Shandong University , Jinan 250061, China
| | - Yannick Coffinier
- Univ. Lille, CNRS, Centrale Lille, ISEN, Univ. Valenciennes, UMR 8520-IEMN , F-59000 Lille, France
| | - Musen Li
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials (Ministry of Education), Shandong University , Jinan 250061, China
| | - Rabah Boukherroub
- Univ. Lille, CNRS, Centrale Lille, ISEN, Univ. Valenciennes, UMR 8520-IEMN , F-59000 Lille, France
| | - Sabine Szunerits
- Univ. Lille, CNRS, Centrale Lille, ISEN, Univ. Valenciennes, UMR 8520-IEMN , F-59000 Lille, France
| |
Collapse
|
34
|
Liu H, Zhang Y, Liu Z, Wang P, Mo X, Fu W, Liu W, Cheng Y, Han W. LYG1 exerts antitumor function through promoting the activation, proliferation, and function of CD4 + T cells. Oncoimmunology 2017; 6:e1292195. [PMID: 28507796 DOI: 10.1080/2162402x.2017.1292195] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2016] [Revised: 01/30/2017] [Accepted: 02/01/2017] [Indexed: 02/04/2023] Open
Abstract
Identification of novel stimulatory cytokines with antitumor function would have great value in tumor immunotherapy investigations. Here, we report LYG1 (Lysozyme G-like 1) identified through the strategy of Immunogenomics as a novel classical secretory protein with tumor-inhibiting function. LYG1 recombinant protein (rhLYG1) could significantly suppress the growth of B16 tumors in WT B6 mice, but not in SCID-beige mice, Rag1-/- mice, CD4+- or CD8+ T cell-deleted mice. It could increase the number of CD4+ and CD8+ T cells in tumor-infiltrating lymphocytes, tumor-draining lymph nodes, and spleens, and promote IFNγ production by T cells in tumor-bearing mice. In vitro experiments demonstrated that rhLYG1 could directly enhance IFNγ secretion by CD4+ T cells, but not CD8+ T cells. Moreover, it could promote the activation, proliferation, and IFNγ production of tumor antigen-specific CD4+ T cells. The tumor-inhibiting effect of LYG1 was eliminated in Ifng-/- mice. Furthermore, LYG1 deficiency accelerated B16 and LLC1 tumor growth and inhibited the function of T cells. In summary, our findings reveal a tumor-inhibiting role for LYG1 through promoting the activation, proliferation, and function of CD4+ T cells in antitumor immune responses, offering implications for novel tumor immunotherapy.
Collapse
Affiliation(s)
- Huihui Liu
- Department of Immunology, School of Basic Medical Sciences, Peking University Health Science Center, Peking University Center for Human Disease Genomics, Key Laboratory of Medical Immunology, Ministry of Health, Beijing, China.,Department of Hematology, Peking University First Hospital, Beijing, China
| | - Yanfei Zhang
- Department of Immunology, School of Basic Medical Sciences, Peking University Health Science Center, Peking University Center for Human Disease Genomics, Key Laboratory of Medical Immunology, Ministry of Health, Beijing, China.,Genomic Medicine Institute, Geisinger Health System, Danville, CA, USA
| | - Zhengyang Liu
- Department of Immunology, School of Basic Medical Sciences, Peking University Health Science Center, Peking University Center for Human Disease Genomics, Key Laboratory of Medical Immunology, Ministry of Health, Beijing, China
| | - Pingzhang Wang
- Department of Immunology, School of Basic Medical Sciences, Peking University Health Science Center, Peking University Center for Human Disease Genomics, Key Laboratory of Medical Immunology, Ministry of Health, Beijing, China
| | - Xiaoning Mo
- Department of Immunology, School of Basic Medical Sciences, Peking University Health Science Center, Peking University Center for Human Disease Genomics, Key Laboratory of Medical Immunology, Ministry of Health, Beijing, China
| | - Weiwei Fu
- Department of Immunology, School of Basic Medical Sciences, Peking University Health Science Center, Peking University Center for Human Disease Genomics, Key Laboratory of Medical Immunology, Ministry of Health, Beijing, China
| | - Wanchang Liu
- Department of Immunology, School of Basic Medical Sciences, Peking University Health Science Center, Peking University Center for Human Disease Genomics, Key Laboratory of Medical Immunology, Ministry of Health, Beijing, China
| | - Yingying Cheng
- Department of Immunology, School of Basic Medical Sciences, Peking University Health Science Center, Peking University Center for Human Disease Genomics, Key Laboratory of Medical Immunology, Ministry of Health, Beijing, China
| | - Wenling Han
- Department of Immunology, School of Basic Medical Sciences, Peking University Health Science Center, Peking University Center for Human Disease Genomics, Key Laboratory of Medical Immunology, Ministry of Health, Beijing, China
| |
Collapse
|
35
|
|