1
|
Tokeshi M. Microfluidic paper-based analytical devices: proven applications and future prospects in therapeutic drug monitoring, homeland security, and chemical education. ANAL SCI 2025:10.1007/s44211-025-00758-0. [PMID: 40253480 DOI: 10.1007/s44211-025-00758-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2025] [Accepted: 03/24/2025] [Indexed: 04/21/2025]
Abstract
Since the report by Whitesides et al. in 2007 on paper-based microfluidic analytical devices (μPADs), numerous studies have been published. The characteristics of μPADs, such as low cost, simplicity, and suitability for resource-limited settings, make them promising for a wide range of applications, including medical diagnostics, environmental analysis, and food testing. While these applications have been well-documented, this review focuses on the less common applications in therapeutic drug monitoring, homeland security, and chemical education. Specifically, the μPADs discussed in this review were developed for the determination of lithium ions in blood for therapeutic drug monitoring, the determination of the nerve agent VX for homeland security, and the measurement of ascorbic acid and pH for chemical education.
Collapse
Affiliation(s)
- Manabu Tokeshi
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-Ku, Sapporo, 060-8628, Japan.
- Innovative Research Center for Preventive Medical Engineering, Nagoya University, Furo-Cho, Chikusa-Ku, Nagoya, 464-8603, Japan.
- Institute of Nano-Life-Systems, Institutes of Innovation for Future Society, Nagoya University, Furo-Cho, Chikusa-Ku, Nagoya, 464-8603, Japan.
| |
Collapse
|
2
|
Magar HS, Fayez M, Febbraio F, Hassan RYA. Esterase-2 mutant-based nanostructured amperometric biosensors for the selective determination of paraoxon (Neurotoxin). Anal Biochem 2025; 698:115751. [PMID: 39681172 DOI: 10.1016/j.ab.2024.115751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2024] [Revised: 11/29/2024] [Accepted: 12/12/2024] [Indexed: 12/18/2024]
Abstract
Organophosphate pesticides (OPs) are causing non-selective inhibition in enzymatic bioreceptors, thus the enzymatic-inhibition-based traditional assays are not suitable for their specific detection in food and environmental samples. Accordingly, a selective nanostructured electrochemical biosensing system was designed using six mutants of the esterase-2 (EST2 protein) enzymes from A. acidocaldarius to be exploited as targeting bio-receptors for the specific detection of OPs. Each of the EST2 mutant enzymes was immobilized on disposable screen-printed electrodes modified with Aluminum oxide (Al2O3)/Copper (Cu) nanocomposite. Consequently, chronoamperometric assay was fully optimized, and cross-reactivity study was carried out using paraoxon, malathion and chlorpyrifos. The comparative cross-reactivity study was performed on the six mutant proteins in terms of inhibitory percentage over a wide range of pesticide concentrations. Eventually, a wide dynamic inhibition range was achieved while the limit of detection for the paraoxon toxicity was 0.01 nM and the limit of quantification was 0.05 nM. Finally, paraoxon was selectively determined using the newly developed EST-based biosensor in different spiked food samples.
Collapse
Affiliation(s)
- Hend Samy Magar
- Applied Organic Chemistry Department, National Research Centre (NRC), Dokki, Giza, 2622, Egypt
| | - Muhammad Fayez
- Biosensors Research Lab, Zewail City of Science and Technology, 6th October City, Giza, 12578, Egypt
| | - Ferdinando Febbraio
- Institute of Biochemistry and Cell Biology, National Research Council (CNR), Via P. Castellino 111, 80131, Naples, Italy.
| | - Rabeay Y A Hassan
- Biosensors Research Lab, Zewail City of Science and Technology, 6th October City, Giza, 12578, Egypt; Applied Organic Chemistry Department, National Research Centre (NRC), Dokki, Giza, 2622, Egypt.
| |
Collapse
|
3
|
Fashedemi O, Ozoemena OC, Peteni S, Haruna AB, Shai LJ, Chen A, Rawson F, Cruickshank ME, Grant D, Ola O, Ozoemena KI. Advances in human papillomavirus detection for cervical cancer screening and diagnosis: challenges of conventional methods and opportunities for emergent tools. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2025; 17:1428-1450. [PMID: 39775553 PMCID: PMC11706323 DOI: 10.1039/d4ay01921k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2024] [Accepted: 12/19/2024] [Indexed: 01/11/2025]
Abstract
Human papillomavirus (HPV) infection is the main cause of cervical cancer and other cancers such as anogenital and oropharyngeal cancers. The prevention screening and treatment of cervical cancer has remained one of the top priorities of the World Health Organization (WHO). In 2020, the WHO came up with the 90-70-90 strategy aimed at eliminating cervical cancers as a public health problem by the year 2030. One of the key priorities of this strategy is the recommendation for countries to ensure that 70% of their women are screened using a high-performance test by the age of 35, and again by the age of 45. Over the years, several traditional methods (notably, Pap smear and nucleic acid-based techniques) have been used for the detection of cervical cancer. While these methods have significantly reduced the incidence of cervical cancer and death, they still come short of excellence for the total eradication of HPV infection. The challenges include low sensitivity, low specificity, poor reproducibility, the need for high-level specialists, and the high cost of access to the facilities, to mention a few. Interestingly, however, several efforts are being made today to mitigate these challenges. In this review, we discussed the pros and cons of the traditional screening and testing of HPV infections, the efforts being made to improve their performances, and the emergent tools (especially, the electrochemical methods) that promise to revolutionize the screening and testing of HPV infections. The main aim of the review is to provide some novel clues to researchers that would allow for the development of high-performance, affordable, and triage-suitable electrochemical-based diagnostic tools for HPV and cervical cancer.
Collapse
Affiliation(s)
- O Fashedemi
- Advanced Materials Group, Faculty of Engineering, The University of Nottingham, Nottingham NG7 2RD, UK.
| | | | - Siwaphiwe Peteni
- Molecular Science Institute, School of Chemistry, University of the Witwatersrand, Johannesburg 2050, South Africa.
| | - Aderemi B Haruna
- Molecular Science Institute, School of Chemistry, University of the Witwatersrand, Johannesburg 2050, South Africa.
| | - Leshweni J Shai
- Department of Biomedical Sciences, Tshwane University of Technology, Pretoria 0001, South Africa
| | - Aicheng Chen
- Department of Chemistry, University of Guelph, Ontario, Canada
| | - Frankie Rawson
- Advanced Materials Group, Faculty of Engineering, The University of Nottingham, Nottingham NG7 2RD, UK.
| | - Maggie E Cruickshank
- Aberdeen Centre for Women's Health Research, University of Aberdeen, Aberdeen AB25 2ZD, UK
| | - David Grant
- Advanced Materials Group, Faculty of Engineering, The University of Nottingham, Nottingham NG7 2RD, UK.
| | - Oluwafunmilola Ola
- Advanced Materials Group, Faculty of Engineering, The University of Nottingham, Nottingham NG7 2RD, UK.
| | - Kenneth I Ozoemena
- Molecular Science Institute, School of Chemistry, University of the Witwatersrand, Johannesburg 2050, South Africa.
| |
Collapse
|
4
|
Sharifi AR, Mazzaracchio V, Duranti L, Gullo L, Brannetti S, Peyravian M, Kiani MA, Arduini F. Nanopaper Integrated Smart Device: An Opto-Electrochemical Biosensor for Real-Time Dual On-Field Detection of Organophosphorus Pesticides. ACS Sens 2024; 9:6542-6552. [PMID: 39665808 DOI: 10.1021/acssensors.4c02000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2024]
Abstract
The frequent and excessive use of organophosphorus pesticides in the agriculture industry raises persistent concerns regarding their environmental protection and public health implications. Addressing these issues requires the development of affordable and reliable sensing platforms for on-field monitoring to mitigate their adverse impacts promptly. This study utilizes nanocellulose papers (bacterial and TEMPO-oxidized) combined with butyrylcholinesterase to create a novel reagent-free and orthogonal nanobioplatform featuring smart opto-electrochemical dual outputs. An integrated nano-PAD, preloaded with enzymes and enzymatic substrates, is fabricated using wax-printing and screen-printing technologies. The nano-PAD measures opto-electroactive products, specifically indoxyl and thiocholine, whose concentrations correlate directly with the enzymatic inhibition caused by paraoxon, used as the organophosphate model. To enhance user convenience and meet the requirements for smart real-time point-of-need detection, integration of the nano-PAD with a smartphone-operated miniaturized potentiostat and a self-developed portable smart optical reader is achieved. The developed bioanalytical platform, further supported by a self-developed Android application, enables accurate and efficient quantification of dual signals in real time. The system covers a wide detection range of paraoxon (20-100 ppb) and demonstrates reliable recovery levels (ranging from 98 to 107%) in a real matrix, specifically wastewater. Given these demonstrated capabilities, this innovative biosensing strategy holds substantial potential for practical application in environmental surveillance, facilitating timely and informed environmental management decisions, particularly in resource-limited settings where traditional analytical tools are inaccessible.
Collapse
Affiliation(s)
- Amir Reza Sharifi
- Chemistry and Chemical Engineering Research Center of Iran, Tehran 14335-186, Iran
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Via della Ricerca Scientifica 1, Rome 00133, Italy
| | - Vincenzo Mazzaracchio
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Via della Ricerca Scientifica 1, Rome 00133, Italy
| | - Leonardo Duranti
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Via della Ricerca Scientifica 1, Rome 00133, Italy
| | - Ludovica Gullo
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Via della Ricerca Scientifica 1, Rome 00133, Italy
| | - Simone Brannetti
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Via della Ricerca Scientifica 1, Rome 00133, Italy
| | - Mohammad Peyravian
- Chemistry and Chemical Engineering Research Center of Iran, Tehran 14335-186, Iran
| | - Mohammad Ali Kiani
- Chemistry and Chemical Engineering Research Center of Iran, Tehran 14335-186, Iran
| | - Fabiana Arduini
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Via della Ricerca Scientifica 1, Rome 00133, Italy
- SENSE4MED, via Bitonto 139, Rome 00133, Italy
| |
Collapse
|
5
|
Manoharan
Nair Sudha Kumari S, Thankappan Suryabai X. Sensing the Future-Frontiers in Biosensors: Exploring Classifications, Principles, and Recent Advances. ACS OMEGA 2024; 9:48918-48987. [PMID: 39713646 PMCID: PMC11656264 DOI: 10.1021/acsomega.4c07991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/04/2024] [Revised: 10/29/2024] [Accepted: 11/18/2024] [Indexed: 12/24/2024]
Abstract
Biosensors are transforming healthcare by delivering swift, precise, and economical diagnostic solutions. These analytical instruments combine biological indicators with physical transducers to identify and quantify biomarkers, thereby improving illness detection, management, and patient surveillance. Biosensors are widely utilized in healthcare for the diagnosis of chronic and infectious diseases, tailored treatment, and real-time health monitoring. This thorough overview examines several categories of biosensors and their uses in the detection of numerous biomarkers, including glucose, proteins, nucleic acids, and infections. Biosensors are commonly classified based on the type of transducer employed or the specific biorecognition element utilized. This review introduces a novel classification based on substrate morphology, offering a comprehensive perspective on biosensor categorization. Considerable emphasis is placed on the advancement of point-of-care biosensors, facilitating decentralized diagnostics and alleviating the strain on centralized healthcare systems. Recent advancements in nanotechnology have significantly improved the sensitivity, selectivity, and downsizing of biosensors, rendering them more efficient and accessible. The study examines problems such as stability, reproducibility, and regulatory approval that must be addressed to enable the widespread implementation of biosensors in clinical environments. The study examines the amalgamation of biosensors with wearable devices and smartphones, emphasizing the prospects for ongoing health surveillance and individualized medical care. This viewpoint clarifies the distinct types of biosensors and their particular roles, together with recent developments in the "smart biosensor" sector, facilitated by artificial intelligence and the Internet of Medical Things (IoMT). This novel approach seeks to deliver a comprehensive evaluation of the present condition of biosensor technology in healthcare, recent developments, and prospective paths, emphasizing their significance in influencing the future of medical diagnostics and patient care.
Collapse
Affiliation(s)
- Sumitha Manoharan
Nair Sudha Kumari
- Centre for
Advanced Materials Research, Department of Physics, Government College for Women, Thiruvananthapuram, University of Kerala, Kerala 695014, India
| | - Xavier Thankappan Suryabai
- Centre for
Advanced Materials Research, Department of Physics, Government College for Women, Thiruvananthapuram, University of Kerala, Kerala 695014, India
| |
Collapse
|
6
|
Colozza N, Mazzaracchio V, Arduini F. Paper-Based Electrochemical (Bio)Sensors for the Detection of Target Analytes in Liquid, Aerosol, and Solid Samples. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2024; 17:127-147. [PMID: 38640070 DOI: 10.1146/annurev-anchem-061522-034228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/21/2024]
Abstract
The last decade has been incredibly fruitful in proving the multifunctionality of paper for delivering innovative electrochemical (bio)sensors. The paper material exhibits unprecedented versatility to deal with complex liquid matrices and facilitate analytical detection in aerosol and solid phases. Such remarkable capabilities are feasible by exploiting the intrinsic features of paper, including porosity, capillary forces, and its easy modification, which allow for the fine designing of a paper device. In this review, we shed light on the most relevant paper-based electrochemical (bio)sensors published in the literature so far to identify the smart functional roles that paper can play to bridge the gap between academic research and real-world applications in the biomedical, environmental, agrifood, and security fields. Our analysis aims to highlight how paper's multifarious properties can be artfully harnessed for breaking the boundaries of the most classical applications of electrochemical (bio)sensors.
Collapse
Affiliation(s)
- Noemi Colozza
- 1Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy;
- 2Sense4Med S.R.L., Rome, Italy
| | - Vincenzo Mazzaracchio
- 1Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy;
| | - Fabiana Arduini
- 1Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy;
- 2Sense4Med S.R.L., Rome, Italy
| |
Collapse
|
7
|
Saya L, Ratandeep, Arya B, Rastogi K, Verma M, Rani S, Sahu PK, Singh MR, Singh WR, Hooda S. Recent advances in sensing toxic nerve agents through DMMP model simulant using diverse nanomaterials-based chemical sensors. Talanta 2024; 272:125785. [PMID: 38394750 DOI: 10.1016/j.talanta.2024.125785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Revised: 02/08/2024] [Accepted: 02/12/2024] [Indexed: 02/25/2024]
Abstract
Recent terrorist assaults have demonstrated the need for the exploration and design of sustainable and stable chemical sensors with quick reaction times combined with great sensitivity. Among several classes of chemical warfare agents, nerve agents have been proven to be the most hazardous. Even short-term exposure to them can result in severe toxic effects. Human beings inadvertently face the after-effects of these chemicals even several years after these chemicals were used. Due to the extreme toxicity and difficulty in handling, dimethyl methylphosphonate (DMMP), a simulant of nerve agents with much lesser toxicity, is frequently used in laboratories as a substitute. Having a chemical structure almost identical to those of nerve agents, DMMP can mimic the properties of nerve agents. Through this paper, authors have attempted to introduce the evolution of several chemical sensors used to detect DMMP in recent years, including field-effect transistors, chemicapacitors, chemiresistors, and mass-sensitive sensors. A detailed discussion of the role of nanomaterials as chemical sensors in the detection of DMMP has been the main focus of the work through a comprehensive overview of the research on gas sensors that have been reported making use of the properties of a wide range of nanomaterials.
Collapse
Affiliation(s)
- Laishram Saya
- Department of Chemistry, Sri Venkateswara College (University of Delhi), Dhaula Kuan, New Delhi 110021, India; Department of Chemistry, Manipur University, Canchipur, Imphal 795003, Manipur, India; Polymer Research Laboratory, Department of Chemistry, Acharya Narendra Dev College (University of Delhi), Govindpuri, Kalkaji, New Delhi, 110019, India.
| | - Ratandeep
- School of Chemical Sciences and Advanced Materials Research Center, Indian Institute of Technology Mandi, Kamand, Mandi 175075, Himachal Pradesh, India
| | - Bipasa Arya
- Polymer Research Laboratory, Department of Chemistry, Acharya Narendra Dev College (University of Delhi), Govindpuri, Kalkaji, New Delhi, 110019, India
| | - Kanjika Rastogi
- Polymer Research Laboratory, Department of Chemistry, Acharya Narendra Dev College (University of Delhi), Govindpuri, Kalkaji, New Delhi, 110019, India
| | - Manisha Verma
- Department of Physics, Acharya Narendra Dev College, (University of Delhi), Govindpuri, Kalkaji, New Delhi, 110019, India
| | - Sanjeeta Rani
- Department of Physics, Acharya Narendra Dev College, (University of Delhi), Govindpuri, Kalkaji, New Delhi, 110019, India
| | - Prasanta Kumar Sahu
- Department of Chemistry, Shivaji College, (University of Delhi), Raja Garden, New Delhi, 110027, India
| | - M Ramananda Singh
- Department of Chemistry, Kirorimal College, (University of Delhi), Delhi, 110007, India
| | - W Rameshwor Singh
- Department of Chemistry, Manipur University, Canchipur, Imphal 795003, Manipur, India.
| | - Sunita Hooda
- Polymer Research Laboratory, Department of Chemistry, Acharya Narendra Dev College (University of Delhi), Govindpuri, Kalkaji, New Delhi, 110019, India.
| |
Collapse
|
8
|
Zhu F, Zhang H, Wu R, Lu Y, Wang J, A R, G TS, Zhu N, Zhang Z, Tang J. A dual-signal aptasensor based on cascade amplification for ultrasensitive detection of aflatoxin B1. Biosens Bioelectron 2024; 250:116057. [PMID: 38286091 DOI: 10.1016/j.bios.2024.116057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 01/02/2024] [Accepted: 01/19/2024] [Indexed: 01/31/2024]
Abstract
Aflatoxin B1 (AFB1) is considered as a serious carcinogenic mycotoxin that was widely detected in grains and foods, and its sensitive analysis is of key importance to avoid the health threats for consumers. In this study, a dual-signal aptasensor based on cascade of entropy-driven strand displacement reaction (ESDR) and linear rolling circle amplification (LRCA) was fabricated for ultrasensitive determination of AFB1. At the sensing system, the complementary strand would be released after the aptamer combined with AFB1, which will bring about the functional domains exposed, triggering the subsequent ESDR. Meanwhile, the two strands that were outputted by ESDR would incur the downstream LRCA reaction to produce a pair of long strands to assist in the generation of fluorescence and absorbance signals. Under the optimized conditions, the proposed aptasensor could achieve excellent sensitivity (limit of detection, 0.427 pg/mL) with satisfactory accuracy (recoveries, 92.8-107.9 %; RSD, 2.4-5.0 %), mainly ascribed to the cascade amplification. Importantly, owing to the flexibility design of nucleic acid primer, this analytical method can be applied in monitoring various hazardous substances according to the specific requirements. Our strategy provides some novel insights at signal amplification for rapid detection of AFB1 and other targets.
Collapse
Affiliation(s)
- Fang Zhu
- School of Emergency Management, School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang, 212013, China; School of Food and Biological Engineering, Jiangsu University, Zhenjiang, 212013, China
| | - Hu Zhang
- School of Emergency Management, School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang, 212013, China
| | - Ruoxi Wu
- School of Emergency Management, School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang, 212013, China
| | - Yanyan Lu
- School of Emergency Management, School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang, 212013, China
| | - Jin Wang
- School of Emergency Management, School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang, 212013, China
| | - Ravikumar A
- School of Emergency Management, School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang, 212013, China
| | - Tamil Selvan G
- School of Emergency Management, School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang, 212013, China
| | - Nuanfei Zhu
- School of Emergency Management, School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang, 212013, China
| | - Zhen Zhang
- School of Emergency Management, School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang, 212013, China.
| | - Jun Tang
- Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, 310015, China.
| |
Collapse
|
9
|
Seddaoui N, Colozza N, Gullo L, Arduini F. Paper as smart support for bioreceptor immobilization in electrochemical paper-based devices. Int J Biol Macromol 2023; 253:127409. [PMID: 37848114 DOI: 10.1016/j.ijbiomac.2023.127409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 10/08/2023] [Accepted: 10/10/2023] [Indexed: 10/19/2023]
Abstract
The use of paper as a smart support in the field of electrochemical sensors has been largely improved over the last 15 years, driven by its outstanding features such as foldability and porosity, which enable the design of reagent and equipment-free multi-analysis devices. Furthermore, the easy surface engineering of paper has been used to immobilize different bioreceptors, through physical adsorption, covalent bonding, and electrochemical polymerization, boosting the fine customization of the analytical performances of paper-based biosensors. In this review, we focused on the strategies to engineer the surface of the paper for the immobilization of (bio)recognition elements (eg., enzymes, antibodies, DNA, molecularly imprinted polymers) with the overriding goal to develop accurate and reliable paper-based electrochemical biosensors. Furthermore, we highlighted how to take advantage of paper for designing smart configurations by integrating different analytical processes in an eco-designed analytical tool, starting from the immobilization of the (bio)receptor and the reagents, through a designed sample flow along the device, until the analyte detection.
Collapse
Affiliation(s)
- Narjiss Seddaoui
- Department of Chemical Science and Technologies, University of Rome "Tor Vergata", Via della Ricerca Scientifica, 00133 Rome, Italy
| | - Noemi Colozza
- Department of Chemical Science and Technologies, University of Rome "Tor Vergata", Via della Ricerca Scientifica, 00133 Rome, Italy; SENSE4MED S.R.L, Via Bitonto 139, 00133 Rome, Italy
| | - Ludovica Gullo
- Department of Chemical Science and Technologies, University of Rome "Tor Vergata", Via della Ricerca Scientifica, 00133 Rome, Italy
| | - Fabiana Arduini
- Department of Chemical Science and Technologies, University of Rome "Tor Vergata", Via della Ricerca Scientifica, 00133 Rome, Italy; SENSE4MED S.R.L, Via Bitonto 139, 00133 Rome, Italy.
| |
Collapse
|
10
|
Kumari R, Singh A, Azad UP, Chandra P. Insights into the Fabrication and Electrochemical Aspects of Paper Microfluidics-Based Biosensor Module. BIOSENSORS 2023; 13:891. [PMID: 37754125 PMCID: PMC10526938 DOI: 10.3390/bios13090891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 09/08/2023] [Accepted: 09/14/2023] [Indexed: 09/28/2023]
Abstract
Over the past ten years, microfluidic paper-based analytical devices (micro-PADs) have attracted a lot of attention as a viable analytical platform. It is expanding as a result of advances in manufacturing processes and device integration. Conventional microfluidics approaches have some drawbacks, including high costs, lengthy evaluation times, complicated fabrication, and the necessity of experienced employees. Hence, it is extremely important to construct a detection system that is quick, affordable, portable, and efficient. Nowadays, micro-PADs are frequently employed, particularly in electrochemical analyses, to replicate the classic standard laboratory experiments on a miniature paper chip. It has benefits like rapid assessment, small sample consumption, quick reaction, accuracy, and multiplex function. The goal of this review is to examine modern paper microfluidics-based electrochemical sensing devices for the detection of macromolecules, small molecules, and cells in a variety of real samples. The design and fabrication of micro-PADs using conventional and the latest techniques have also been discussed in detail. Lastly, the limitations and potential of these analytical platforms are examined in order to shed light on future research.
Collapse
Affiliation(s)
- Rohini Kumari
- Laboratory of Bio-Physio Sensors and Nanobioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi 221005, Uttar Pradesh, India; (R.K.); (A.S.)
| | - Akanksha Singh
- Laboratory of Bio-Physio Sensors and Nanobioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi 221005, Uttar Pradesh, India; (R.K.); (A.S.)
| | - Uday Pratap Azad
- Laboratory of Nanoelectrochemistry, Department of Chemistry, Guru Ghasidas Vishwavidyalaya (Central University), Bilaspur 495009, Chhattisgarh, India;
| | - Pranjal Chandra
- Laboratory of Bio-Physio Sensors and Nanobioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi 221005, Uttar Pradesh, India; (R.K.); (A.S.)
| |
Collapse
|
11
|
Zhu L, Wu M, Li R, Zhao Y, Lu Y, Wang T, Du L, Wan L. Research progress on pesticide residue detection based on microfluidic technology. Electrophoresis 2023; 44:1377-1404. [PMID: 37496295 DOI: 10.1002/elps.202300048] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 06/30/2023] [Accepted: 07/04/2023] [Indexed: 07/28/2023]
Abstract
The problem of pesticide residue contamination has attracted widespread attention and poses a risk to human health. The current traditional pesticide residue detection methods have difficulty meeting rapid and diverse field screening requirements. Microfluidic technology integrates functions from sample preparation to detection, showing great potential for quick and accurate high-throughput detection of pesticide residues. This paper reviews the latest research progress on microfluidic technology for pesticide residue detection. First, the commonly used microfluidic materials are summarized, including silicon, glass, paper, polydimethylsiloxane, and polymethyl methacrylate. We evaluated their advantages and disadvantages in pesticide residue detection applications. Second, the current pesticide residue detection technology based on microfluidics and its application to real samples are summarized. Finally, we discuss this technology's present challenges and future research directions. This study is expected to provide a reference for the future development of microfluidic technology for pesticide residue detection.
Collapse
Affiliation(s)
- Lv Zhu
- State Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, P. R. China
| | - Mengyao Wu
- State Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, P. R. China
| | - Ruiyu Li
- State Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, P. R. China
| | - Yunyan Zhao
- State Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, P. R. China
| | - Yang Lu
- State Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, P. R. China
| | - Ting Wang
- State Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, P. R. China
| | - Leilei Du
- State Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, P. R. China
- School of Ethnic Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu, P. R. China
| | - Li Wan
- State Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, P. R. China
| |
Collapse
|
12
|
Taufiq S, Waqar M, Sharif MN, Abbas SR. Towards portable rapid TB biosensor: Detecting Mycobacterium tuberculosis in raw sputum samples using functionalized screen printed electrodes. Bioelectrochemistry 2023; 150:108353. [PMID: 36603412 DOI: 10.1016/j.bioelechem.2022.108353] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 12/12/2022] [Accepted: 12/14/2022] [Indexed: 12/23/2022]
Abstract
Due to lack of robust, sensitive and low cost detection strategies, Tuberculosis (TB) remains a significant global health issue. WHO reports 1.5 million deaths per year, ∼80 % cases occur in low- to middle-income countries, where resource limitations complicate the diagnosis. Robust detection of TB infection is important to contain the spread and treat disease. We developed a label-free DNA biosensor based on commercially available screen printed electrodes (SPEs) (DropSens and Zensors) that can detect TB robustly, sensitively, and specifically via DNA hybridization with its IS6110 gene marker, in purified DNA and raw sputum samples. The fabricated biosensor was morphologically characterized by scanning electron microscopy coupled with energy dispersive X-ray spectroscopy. Cyclic voltammetry and Differential Pulse Voltammetry was used for electrochemical analysis of the modified electrode. The fabricated biosensor demonstrated satisfactory selectivity for Mycobacterium tuberculosis (MTB) against Salmonella typhimurium and Escherichia coli and was able to detect MTB; the limit of detection (LOD) of 1.90 nM with R2 = 0.993, when analyzed over a range of concentrations of DNA (0.5-10 nM). It is being exploited to detect target MTB from clinical samples, without DNA purification. The approach is robust, sensitive, and specific, requires low sample volume and can be extended towards portable point of care diagnosis of TB.
Collapse
Affiliation(s)
- Saman Taufiq
- Department of Industrial Biotechnology, Atta ur Rahman School of Applied Biosciences, National University of Science and Technology (NUST), Islamabad, Pakistan; Biosensors and Therapeutics Lab, School of Interdisciplinary Engineering and Sciences (SINES), NUST, Islamabad, Pakistan.
| | - Muhammad Waqar
- Department of Industrial Biotechnology, Atta ur Rahman School of Applied Biosciences, National University of Science and Technology (NUST), Islamabad, Pakistan
| | - Muhammad Nauman Sharif
- Department of Industrial Biotechnology, Atta ur Rahman School of Applied Biosciences, National University of Science and Technology (NUST), Islamabad, Pakistan; Biosensors and Therapeutics Lab, School of Interdisciplinary Engineering and Sciences (SINES), NUST, Islamabad, Pakistan.
| | - Shah Rukh Abbas
- Department of Industrial Biotechnology, Atta ur Rahman School of Applied Biosciences, National University of Science and Technology (NUST), Islamabad, Pakistan; Biosensors and Therapeutics Lab, School of Interdisciplinary Engineering and Sciences (SINES), NUST, Islamabad, Pakistan.
| |
Collapse
|
13
|
Al-Faiyz YSS, Sarfaraz S, Yar M, Munsif S, Khan AA, Amin B, Sheikh NS, Ayub K. Efficient Detection of Nerve Agents through Carbon Nitride Quantum Dots: A DFT Approach. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:251. [PMID: 36678006 PMCID: PMC9864457 DOI: 10.3390/nano13020251] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 12/29/2022] [Accepted: 01/01/2023] [Indexed: 06/17/2023]
Abstract
V-series nerve agents are very lethal to health and cause the inactivation of acetylcholinesterase which leads to neuromuscular paralysis and, finally, death. Therefore, rapid detection and elimination of V-series nerve agents are very important. Herein, we have carried out a theoretical investigation of carbon nitride quantum dots (C2N) as an electrochemical sensor for the detection of V-series nerve agents, including VX, VS, VE, VG, and VM. Adsorption of V-series nerve agents on C2N quantum dots is explored at M05-2X/6-31++G(d,p) level of theory. The level of theory chosen is quite adequate in systems describing non-bonding interactions. The adsorption behavior of nerve agents is characterized by interaction energy, non-covalent interaction (NCI), Bader's quantum theory of atoms in molecules (QTAIM), frontier molecular orbital (FMO), electron density difference (EDD), and charge transfer analysis. The computed adsorption energies of the studied complexes are in the range of -12.93 to -17.81 kcal/mol, which indicates the nerve agents are physiosorbed onto C2N surface through non-covalent interactions. The non-covalent interactions between V-series and C2N are confirmed through NCI and QTAIM analysis. EDD analysis is carried out to understand electron density shifting, which is further validated by natural bond orbital (NBO) analysis. FMO analysis is used to estimate the changes in energy gap of C2N on complexation through HOMO-LUMO energies. These findings suggest that C2N surface is highly selective toward VX, and it might be a promising candidate for the detection of V-series nerve agents.
Collapse
Affiliation(s)
- Yasair S. S. Al-Faiyz
- Department of Chemistry, College of Science, King Faisal University, Al-Ahsa 31982, Saudi Arabia
| | - Sehrish Sarfaraz
- Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, Abbottabad 22060, Pakistan
| | - Muhammad Yar
- Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, Abbottabad 22060, Pakistan
| | - Sajida Munsif
- Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, Abbottabad 22060, Pakistan
| | - Adnan Ali Khan
- Centre for Computational Materials Science, University of Malakand, Chakdara 18800, Pakistan
- Department of Chemistry, University of Malakand, Chakdara 18800, Pakistan
| | - Bin Amin
- Department of Physics, Abbottabad University of Science & Technology, Abbottabad 22010, Pakistan
| | - Nadeem S. Sheikh
- Chemical Sciences, Faculty of Science, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong BE1410, Brunei
| | - Khurshid Ayub
- Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, Abbottabad 22060, Pakistan
| |
Collapse
|
14
|
Magar HS, Magd EEAE, Hassan RY, Fahim AM. Rapid impedimetric detection of cadmium ions using Nanocellulose/ligand/nanocomposite (CNT/Co3O4). Microchem J 2022. [DOI: 10.1016/j.microc.2022.107885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
15
|
Recent advances in enzyme inhibition based-electrochemical biosensors for pharmaceutical and environmental analysis. Talanta 2022. [DOI: 10.1016/j.talanta.2022.124092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
16
|
Silveri F, Della Pelle F, Scroccarello A, Mazzotta E, Di Giulio T, Malitesta C, Compagnone D. Carbon Black Functionalized with Naturally Occurring Compounds in Water Phase for Electrochemical Sensing of Antioxidant Compounds. Antioxidants (Basel) 2022; 11:antiox11102008. [PMID: 36290731 PMCID: PMC9598705 DOI: 10.3390/antiox11102008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 10/04/2022] [Accepted: 10/04/2022] [Indexed: 11/18/2022] Open
Abstract
A new sustainable route to nanodispersed and functionalized carbon black in water phase (W-CB) is proposed. The sonochemical strategy exploits ultrasounds to disaggregate the CB, while two selected functional naturally derived compounds, sodium cholate (SC) and rosmarinic acid (RA), act as stabilizing agents ensuring dispersibility in water adhering onto the CB nanoparticles’ surface. Strategically, the CB-RA compound is used to drive the AuNPs self-assembling at room temperature, resulting in a CB surface that is nanodecorated; further, this is achieved without the need for additional reagents. Electrochemical sensors based on the proposed nanomaterials are realized and characterized both morphologically and electrochemically. The W-CBs’ electroanalytical potential is proved in the anodic and cathodic window using caffeic acid (CF) and hydroquinone (HQ), two antioxidant compounds that are significant for food and the environment. For both antioxidants, repeatable (RSD ≤ 3.3%; n = 10) and reproducible (RSD ≤ 3.8%; n = 3) electroanalysis results were obtained, achieving nanomolar detection limits (CF: 29 nM; HQ: 44 nM). CF and HQ are successfully determined in food and environmental samples (recoveries 97–113%), and also in the presence of other phenolic classes and HQ structural isomers. The water dispersibility of the proposed materials can be an opportunity for (bio) sensor fabrication and sustainable device realization.
Collapse
Affiliation(s)
- Filippo Silveri
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via R. Balzarini 1, 64100 Teramo, Italy
| | - Flavio Della Pelle
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via R. Balzarini 1, 64100 Teramo, Italy
- Correspondence: (F.D.P.); (D.C.); Tel.: +39-0861-266948 (F.D.P.); +39-0861-266942 (D.C.)
| | - Annalisa Scroccarello
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via R. Balzarini 1, 64100 Teramo, Italy
| | - Elisabetta Mazzotta
- Laboratorio di Chimica Analitica, Dipartimento di Scienze e Tecnologie Biologiche e Ambientali (Di.S.Te.B.A.), Universitaà del Salento, Via Monteroni, 73100 Lecce, Italy
| | - Tiziano Di Giulio
- Laboratorio di Chimica Analitica, Dipartimento di Scienze e Tecnologie Biologiche e Ambientali (Di.S.Te.B.A.), Universitaà del Salento, Via Monteroni, 73100 Lecce, Italy
| | - Cosimino Malitesta
- Laboratorio di Chimica Analitica, Dipartimento di Scienze e Tecnologie Biologiche e Ambientali (Di.S.Te.B.A.), Universitaà del Salento, Via Monteroni, 73100 Lecce, Italy
| | - Dario Compagnone
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via R. Balzarini 1, 64100 Teramo, Italy
- Correspondence: (F.D.P.); (D.C.); Tel.: +39-0861-266948 (F.D.P.); +39-0861-266942 (D.C.)
| |
Collapse
|
17
|
Kaur H, Siwal SS, Chauhan G, Saini AK, Kumari A, Thakur VK. Recent advances in electrochemical-based sensors amplified with carbon-based nanomaterials (CNMs) for sensing pharmaceutical and food pollutants. CHEMOSPHERE 2022; 304:135182. [PMID: 35667504 DOI: 10.1016/j.chemosphere.2022.135182] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 05/18/2022] [Accepted: 05/28/2022] [Indexed: 06/15/2023]
Abstract
Foodborne-related infections due to additives and pollutants pose a considerable task for food processing enterprises. Therefore, the competent, cost-effective, and quick investigation of nutrition additives and contaminants is essential to reduce the threat of public fitness problems. The electrochemical sensor (ECS) shows facile and potent analytical approaches desirable for food protection and quality inspection over traditional methods. The consequence of a broad display of nanomaterials has paved the path for their relevance in designing high-performance ECSs appliances for medical diagnostics and conditions and food protection. This review article has discussed the importance of electrochemical-based sensors amplified with carbon-based nanomaterials (CNMs). Initially, we have demonstrated the types of pharmaceutical and food/agriculture pollutants (such as pesticides, heavy metals, antibiotics and other medical drugs) present in water. Subsequently, we have compiled the information on electrochemical techniques (such as voltammetric and electrochemical impedance spectroscopy) and their crucial parameters for detecting pollutants. Further, the applications of CNMs for sensing pharmaceutical and food pollutants have been demonstrated in detail. Finally, the topic has been concluded with existing challenges and future prospects.
Collapse
Affiliation(s)
- Harjot Kaur
- Department of Chemistry, M.M. Engineering College, Maharishi Markandeshwar (Deemed to Be University), Mullana-Ambala, Haryana, 133207, India
| | - Samarjeet Singh Siwal
- Department of Chemistry, M.M. Engineering College, Maharishi Markandeshwar (Deemed to Be University), Mullana-Ambala, Haryana, 133207, India.
| | - Gunjan Chauhan
- Department of Chemistry, M.M. Engineering College, Maharishi Markandeshwar (Deemed to Be University), Mullana-Ambala, Haryana, 133207, India
| | - Adesh Kumar Saini
- Department of Biotechnology, Maharishi Markandeshwar (Deemed to Be University), Mullana-Ambala, Haryana, 133207, India
| | - Anita Kumari
- Department of Chemistry, GGDSD College Rajpur (Palampur), Himachal Pradesh University, Shimla, 176061, India
| | - Vijay Kumar Thakur
- Biorefining and Advanced Materials Research Center, Scotland's Rural College (SRUC), Kings Buildings, Edinburgh, EH9 3JG, UK; School of Engineering, University of Petroleum & Energy Studies (UPES), Dehradun, Uttarakhand, India; Centre for Research & Development, Chandigarh University, Mohali, 140413, Punjab, India.
| |
Collapse
|
18
|
Sun Y, Jiang Q, Chen F, Cao Y. Paper‐based electrochemical sensor. ELECTROCHEMICAL SCIENCE ADVANCES 2022. [DOI: 10.1002/elsa.202100057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Affiliation(s)
- Yang Sun
- Department of Forensic Medicine Nanjing Medical University Nanjing Jiangsu P. R. China
| | - Qiao‐Yan Jiang
- Department of Forensic Medicine Nanjing Medical University Nanjing Jiangsu P. R. China
| | - Feng Chen
- Department of Forensic Medicine Nanjing Medical University Nanjing Jiangsu P. R. China
| | - Yue Cao
- Department of Forensic Medicine Nanjing Medical University Nanjing Jiangsu P. R. China
| |
Collapse
|
19
|
Kanapathy S, Obande GA, Chuah C, Shueb RH, Yean CY, Banga Singh KK. Sequence-Specific Electrochemical Genosensor for Rapid Detection of blaOXA-51-like Gene in Acinetobacter baumannii. Microorganisms 2022; 10:1413. [PMID: 35889132 PMCID: PMC9322073 DOI: 10.3390/microorganisms10071413] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 07/04/2022] [Accepted: 07/07/2022] [Indexed: 11/26/2022] Open
Abstract
Acinetobacter baumannii (A. baumannii) are phenotypically indistinguishable from the Acinetobacter calcoaceticus−A. baumannii (ACB) complex members using routine laboratory methods. Early diagnosis plays an important role in controlling A. baumannii infections and this could be assisted by the development of a rapid, yet sensitive diagnostic test. In this study, we developed an enzyme-based electrochemical genosensor for asymmetric PCR (aPCR) amplicon detection of the blaOXA-51-like gene in A. baumannii. A. baumanniiblaOXA-51-like gene PCR primers were designed, having the reverse primer modified at the 5′ end with FAM. A blaOXA-51-like gene sequence-specific biotin labelled capture probe was designed and immobilized using a synthetic oligomer (FAM-labelled) deposited on the working electrode of a streptavidin-modified, screen-printed carbon electrode (SPCE). The zot gene was used as an internal control with biotin and FAM labelled as forward and reverse primers, respectively. The blaOXA-51-like gene was amplified using asymmetric PCR (aPCR) to generate single-stranded amplicons that were detected using the designed SPCE. The amperometric current response was detected with a peroxidase-conjugated, anti-fluorescein antibody. The assay was tested using reference and clinical A. baumannii strains and other nosocomial bacteria. The analytical sensitivity of the assay at the genomic level and bacterial cell level was 0.5 pg/mL (1.443 µA) and 103 CFU/mL, respectively. The assay was 100% specific and sensitive for A. baumannii. Based on accelerated stability performance, the developed genosensor was stable for 1.6 years when stored at 4 °C and up to 28 days at >25 °C. The developed electrochemical genosensor is specific and sensitive and could be useful for rapid, accurate diagnosis of A. baumannii infections even in temperate regions.
Collapse
Affiliation(s)
- Swarnaletchumi Kanapathy
- Department of Medical Microbiology & Parasitology, School of Medical Sciences, Universiti Sains Malaysia, Health Campus, Kubang Kerian 16150, Kelantan, Malaysia; (S.K.); (C.C.); (R.H.S.); (C.Y.Y.)
| | - Godwin Attah Obande
- Department of Microbiology, Faculty of Science, Federal University of Lafia, Lafia 950101, Nasarawa State, Nigeria;
| | - Candy Chuah
- Department of Medical Microbiology & Parasitology, School of Medical Sciences, Universiti Sains Malaysia, Health Campus, Kubang Kerian 16150, Kelantan, Malaysia; (S.K.); (C.C.); (R.H.S.); (C.Y.Y.)
- Faculty of Health Sciences, Universiti Teknologi MARA, Kampus Bertam, Kepala Batas 13200, Penang, Malaysia
| | - Rafidah Hanim Shueb
- Department of Medical Microbiology & Parasitology, School of Medical Sciences, Universiti Sains Malaysia, Health Campus, Kubang Kerian 16150, Kelantan, Malaysia; (S.K.); (C.C.); (R.H.S.); (C.Y.Y.)
| | - Chan Yean Yean
- Department of Medical Microbiology & Parasitology, School of Medical Sciences, Universiti Sains Malaysia, Health Campus, Kubang Kerian 16150, Kelantan, Malaysia; (S.K.); (C.C.); (R.H.S.); (C.Y.Y.)
| | - Kirnpal Kaur Banga Singh
- Department of Medical Microbiology & Parasitology, School of Medical Sciences, Universiti Sains Malaysia, Health Campus, Kubang Kerian 16150, Kelantan, Malaysia; (S.K.); (C.C.); (R.H.S.); (C.Y.Y.)
| |
Collapse
|
20
|
A paper-based electrochemical device for the detection of pesticides in aerosol phase inspired by nature: A flower-like origami biosensor for precision agriculture. Biosens Bioelectron 2022; 205:114119. [DOI: 10.1016/j.bios.2022.114119] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 02/16/2022] [Accepted: 02/18/2022] [Indexed: 11/18/2022]
|
21
|
Silveri F, Della Pelle F, Scroccarello A, Ain Bukhari QU, Del Carlo M, Compagnone D. Modular graphene mediator film-based electrochemical pocket device for chlorpyrifos determination. Talanta 2022; 240:123212. [PMID: 35026635 DOI: 10.1016/j.talanta.2022.123212] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Revised: 12/01/2021] [Accepted: 01/04/2022] [Indexed: 12/12/2022]
Abstract
In this work, a redox-graphene (Rx-Gr) film with electron-mediating ability has been integrated into a modular flexible pocket device, giving rise to a reusable biosensing platform. The Rx-Gr has been obtained in water from graphite taking advantage of catechin, a redox-antioxidant, able to assist the sonochemical layered-material exfoliation, conferring electron mediating feature. A film composed exclusively of Rx-Gr has been transferred via thermal rolling onto a flexible PET-support that was used as the biosensor base. The biosensing platform, composed of office-grade materials, was then fabricated using a cutter-plotter and assembled by thermal lamination; an interchangeable paper-based strip was used to host the enzymatic reaction and drive the capillary flow. An acetylcholinesterase-based inhibition assay has been optimized onboard the pocket device to determine chlorpyriphos, a widespread environmental pesticide. The proposed set-up allows the determination of chlorpyriphos at low overpotential (0.2 V) with satisfactory sensitivity (LOD = 0.2 ppb), thanks to the straightforward electroactivity of the Rx-Gr film towards thiocholine (enzymatic product). The modular design allows 5 consecutive complete inhibition assays (control + inhibition measure) retaining the performance (RSD = 5.4%; n = 5). The coupling of bench-top technologies and a new functional graphene film resulted in the development of a cost-effective, reusable, transportable, and within everyone's reach biosensing platform.
Collapse
Affiliation(s)
- Filippo Silveri
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100, Teramo, Italy
| | - Flavio Della Pelle
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100, Teramo, Italy.
| | - Annalisa Scroccarello
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100, Teramo, Italy
| | - Qurat Ul Ain Bukhari
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100, Teramo, Italy
| | - Michele Del Carlo
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100, Teramo, Italy
| | - Dario Compagnone
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100, Teramo, Italy.
| |
Collapse
|
22
|
Zhang H, Li X, Zhu Q, Wang Z. The recent development of nanomaterials enhanced paper-based electrochemical analytical devices. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116140] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
23
|
Wang L, Peng X, Fu H. An electrochemical aptasensor for the sensitive detection of Pb2+ based on a chitosan/reduced graphene oxide/titanium dioxide. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106977] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
24
|
Li W, Pei Y, Wang J. Development and analysis of a novel AF11-2 aptamer capable of enhancing the fluorescence of aflatoxin B1. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2022.01.040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
25
|
Musile G, Agard Y, Wang L, De Palo EF, McCord B, Tagliaro F. Paper-based microfluidic devices: On-site tools for crime scene investigation. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116406] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
26
|
Electrochemical Biosensors for Tracing Cyanotoxins in Food and Environmental Matrices. BIOSENSORS-BASEL 2021; 11:bios11090315. [PMID: 34562905 PMCID: PMC8468299 DOI: 10.3390/bios11090315] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 08/30/2021] [Accepted: 09/01/2021] [Indexed: 12/13/2022]
Abstract
The adoption of electrochemical principles to realize on-field analytical tools for detecting pollutants represents a great possibility for food safety and environmental applications. With respect to the existing transduction mechanisms, i.e., colorimetric, fluorescence, piezoelectric etc., electrochemical mechanisms offer the tremendous advantage of being easily miniaturized, connected with low cost (commercially available) readers and unaffected by the color/turbidity of real matrices. In particular, their versatility represents a powerful approach for detecting traces of emerging pollutants such as cyanotoxins. The combination of electrochemical platforms with nanomaterials, synthetic receptors and microfabrication makes electroanalysis a strong starting point towards decentralized monitoring of toxins in diverse matrices. This review gives an overview of the electrochemical biosensors that have been developed to detect four common cyanotoxins, namely microcystin-LR, anatoxin-a, saxitoxin and cylindrospermopsin. The manuscript provides the readers a quick guide to understand the main electrochemical platforms that have been realized so far, and the presence of a comprehensive table provides a perspective at a glance.
Collapse
|
27
|
New tools of Electrochemistry at the service of (bio)sensing: From rational designs to electrocatalytic mechanisms. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115097] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
28
|
Yamaguchi A, Miyaguchi H, Ishida A, Tokeshi M. Paper-Based Analytical Device for the On-Site Detection of Nerve Agents. ACS APPLIED BIO MATERIALS 2021; 4:6512-6518. [PMID: 35006863 DOI: 10.1021/acsabm.1c00655] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We report a colorimetric paper-based microfluidic device based on an enzyme inhibition assay that allows the on-site detection of nerve agents by sampling and wicking. The sample and reagents are automatically transported through the channel where an enzyme inhibition reaction is conducted, followed by an enzyme-substrate reaction and a color reaction. This device can detect 0.1 μg/mL of the nerve agent VX in a 2.5 μL drop and is nerve agent selective and robust against temperature, pH, and several liquids. We confirmed that sampling procedures (dilution and wiping) are applicable to this device. Furthermore, the fabrication procedure is easy, and the cost is at most a few tens of cents. Thus, the present device provides a practical method for the urgent detection of nerve agents in suspected chemical terrorism incidents.
Collapse
Affiliation(s)
- Akinori Yamaguchi
- National Research Institute of Police Science, 6-3-1 Kashiwanoha, Kashiwa 277-0882, Japan.,Graduate School of Chemical Sciences and Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan
| | - Hajime Miyaguchi
- National Research Institute of Police Science, 6-3-1 Kashiwanoha, Kashiwa 277-0882, Japan
| | - Akihiko Ishida
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan
| | - Manabu Tokeshi
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan.,Innovative Research Centre for Preventive Medical Engineering, Nagoya University, Furo-cho Chikusa-ku, Nagoya 464-8601, Japan.,Institutes of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan
| |
Collapse
|
29
|
Zou X, Ji Y, Li H, Wang Z, Shi L, Zhang S, Wang T, Gong Z. Recent advances of environmental pollutants detection via paper-based sensing strategy. LUMINESCENCE 2021; 36:1818-1836. [PMID: 34342392 DOI: 10.1002/bio.4130] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 07/28/2021] [Accepted: 07/29/2021] [Indexed: 12/22/2022]
Abstract
Paper has become one of the most promising substrates for building low-cost and powerful sensing platforms due to its self-pumping ability and compatibility with multiple patterning methods. Paper-based sensors have been greatly developed in the field of environmental monitoring. In this review, we introduced the research and application of paper-based sensors in environmental monitoring, focusing on the deposition and patterning methods of building paper-based sensors, and summarized the applications of detecting environmental pollutants, including metal ions, anions, explosives, neurotoxins, volatile organic compounds, and small molecules. In addition, the development prospects and challenges of promoting paper-based sensors are also discussed. The current review will provide references for the construction of portable paper-based sensors, and has implications for the field of on-site real-time detection of the environment.
Collapse
Affiliation(s)
- Xue Zou
- Faculty of Geosciences and Environmental Engineering, Southwest Jiaotong University, Chengdu, Sichuan, China
| | - Yayun Ji
- Faculty of Geosciences and Environmental Engineering, Southwest Jiaotong University, Chengdu, Sichuan, China
| | - Hangzhou Li
- Faculty of Geosciences and Environmental Engineering, Southwest Jiaotong University, Chengdu, Sichuan, China
| | - Zhaoli Wang
- Chengdu Academy of Environmental Sciences, Chengdu, China
| | - Linhong Shi
- Faculty of Geosciences and Environmental Engineering, Southwest Jiaotong University, Chengdu, Sichuan, China
| | - Shengli Zhang
- Faculty of Geosciences and Environmental Engineering, Southwest Jiaotong University, Chengdu, Sichuan, China
| | - Tengfei Wang
- Faculty of Geosciences and Environmental Engineering, Southwest Jiaotong University, Chengdu, Sichuan, China
| | - Zhengjun Gong
- Faculty of Geosciences and Environmental Engineering, Southwest Jiaotong University, Chengdu, Sichuan, China.,State-province Joint Engineering Laboratory of Spatial Information Technology of High-Speed Rail Safety, Chengdu, Sichuan, China
| |
Collapse
|
30
|
Cioffi A, Mancini M, Gioia V, Cinti S. Office Paper-Based Electrochemical Strips for Organophosphorus Pesticide Monitoring in Agricultural Soil. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:8859-8865. [PMID: 34165948 DOI: 10.1021/acs.est.1c01931] [Citation(s) in RCA: 48] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Although the use of pesticides has highlighted obvious advantages on agricultural yields, intensive and widespread pesticide use raises serious environmental and health concerns. In particular, organophosphate pesticides represent >40% of the totality used in the field of agriculture, and developing countries face the issue of agricultural poisoning, also due to scarce monitoring programs. In this work, a decentralized, miniaturized, sustainable, and portable paper-based electrochemical biosensor for the quantification of organophosphorus pesticides' level has been realized. The proposed approach highlights the use of a very common paper-based substrate, namely, office paper. Office paper offers several advantages due to its nature: it allows one to print conductive strips for electrochemical connection, loading bio-hybrid nanosized probes (Prussian blue, carbon black, and butyrylcholinesterase), evaluating pesticides and reducing waste disposal compared to plastic-based strips. The portable system has been characterized by a low detection limit of 1.3 ng/mL, and accordingly to total discovered pesticide contents in EU agricultural soils, up to ca. 3 μg/mL, it can offer a valuable tool for fast monitoring. To demonstrate its effectiveness, soil and fruit vegetables have been used to perform in situ quantification. Good recovery percentages between 90 and 110% have been achieved in different matrices, highlighting to be suitable for field measurements, and a good correlation has been obtained in comparison with LC-MS analysis.
Collapse
Affiliation(s)
- Alessia Cioffi
- Department of Pharmacy, University of Naples "Federico II", Via D. Montesano 49, 80131 Naples, Italy
| | - Marco Mancini
- Acea ElaboRi SpA, Via Vitorchiano 165, 00189 Rome, Italy
| | | | - Stefano Cinti
- Department of Pharmacy, University of Naples "Federico II", Via D. Montesano 49, 80131 Naples, Italy
- BAT Center-Interuniversity Center for Studies on Bioinspired Agro-Environmental Technology, University of Napoli "Federico II", 80055 Portici, Naples, Italy
| |
Collapse
|
31
|
Feasible study on poly(Pyrrole-co-Pyrrole-3-Carboxylic Acid)-modified electrode for detection of 17β-Estradiol. CHEMICAL PAPERS 2021. [DOI: 10.1007/s11696-021-01597-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
32
|
Jiang H, Guo Q, Zhang C, Sun Z, Weng X. Microfluidic origami nano-aptasensor for peanut allergen Ara h1 detection. Food Chem 2021; 365:130511. [PMID: 34237563 DOI: 10.1016/j.foodchem.2021.130511] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 06/22/2021] [Accepted: 06/26/2021] [Indexed: 12/17/2022]
Abstract
In this study, an origami microfluidic electrochemical nano-aptasensor was developed for the rapid detection of the peanut allergen Ara h1. Specifically, the microfluidic aptasensor was fabricated through sequential folding of a piece of chromatography paper substrate patterned with microchannel and screen-printed electrodes. Aptamer-decorated black phosphorus nanosheets (BPNSs) were electrodeposited onto the paper-based electrode surface as sensing probes for enhanced electrochemical detection and high specificity and selectivity. Critical design parameters (the concentration of probe, time for self-assembly of aptamer and reaction time) were investigated to optimize the aptasensor performance. The prepared aptasensor was able to complete detection within 20 min and demonstrated a linear range from 50 ~ 1000 ng/mL with a detection limit of 21.6 ng/mL. The aptasensor was successfully used to detect the Ara h1 spiked cookie dough sample. The proposed method reduces the gap between complex lab testing and food allergen analysis at the point of need.
Collapse
Affiliation(s)
- Hai Jiang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 611731, China; Institute of Electronic and Information Engineering of UESTC in Guangdong, Dongguan, Guangdong 523808, China
| | - Qian Guo
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 611731, China
| | - Cheng Zhang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 611731, China
| | - Zhikang Sun
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 611731, China
| | - Xuan Weng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 611731, China; Institute of Electronic and Information Engineering of UESTC in Guangdong, Dongguan, Guangdong 523808, China.
| |
Collapse
|
33
|
Noviana E, Ozer T, Carrell CS, Link JS, McMahon C, Jang I, Henry CS. Microfluidic Paper-Based Analytical Devices: From Design to Applications. Chem Rev 2021; 121:11835-11885. [DOI: 10.1021/acs.chemrev.0c01335] [Citation(s) in RCA: 91] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Eka Noviana
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Universitas Gadjah Mada, Yogyakarta, Indonesia 55281
| | - Tugba Ozer
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department of Bioengineering, Faculty of Chemical and Metallurgical Engineering, Yildiz Technical University, Istanbul, Turkey 34220
| | - Cody S. Carrell
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Jeremy S. Link
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Catherine McMahon
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Ilhoon Jang
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Institute of Nano Science and Technology, Hanyang University, Seoul, South Korea 04763
| | - Charles S. Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| |
Collapse
|
34
|
Abstract
Membraneless microfluidic fuel cells (MMFCs) are being studied extensively as an alternative to batteries and conventional membrane fuel cells because of their simple functioning and lower manufacturing cost. MMFCs use the laminar flow of reactant species (fuel and oxidant) to eliminate the electrolyte membrane, which has conventionally been used to isolate anodic and cathodic half-cell reactions. This review article summarizes the MMFCs with six major categories of flow configurations that have been reported from 2002 to 2020. The discussion highlights the critical factors that affect and limit the performance of MMFCs. Since MMFCs are diffusion-limited, most of this review focuses on how different flow configurations act to reduce or modify diffusive mixing and depletion zones to enhance the power density output. Research opportunities are also pointed out, and the challenges in MMFCs are suggested to improve cell performance and make them practical in the near future.
Collapse
|
35
|
Rana K, Mittal J, Narang J, Mishra A, Pudake RN. Graphene Based Electrochemical DNA Biosensor for Detection of False Smut of Rice (Ustilaginoidea virens). THE PLANT PATHOLOGY JOURNAL 2021; 37:291-298. [PMID: 34111918 PMCID: PMC8200582 DOI: 10.5423/ppj.oa.11.2020.0207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Revised: 04/19/2021] [Accepted: 05/15/2021] [Indexed: 06/12/2023]
Abstract
False smut caused by Ustilaginoidea virens is an important rice fungal disease that significantly decreases its production. In the recent past, conventional methods have been developed for its detection that is time-consuming and need high-cost equipments. The research and development in nanotechnology have made it possible to assemble efficient recognition interfaces in biosensors. In this study, we present a simple, sensitive, and selective oxidized graphene-based geno-biosensor for the detection of rice false smut. The biosensor has been developed using a probe DNA as a biological recognition element on paper electrodes, and oxidized graphene to enhance the limit of detection and sensitivity of the sensor. Probe single-stranded DNA (ssDNA) and target ssDNA hybridization on the interface surface has been quantitatively measured with the electrochemical analysis tools namely, cyclic voltammetry, and linear sweep voltammetry. To confirm the selectivity of the device, probe hybridization with non-complementary ssDNA target has been studied. In our study, the developed sensor was able to detect up to 10 fM of target ssDNA. The paper electrodes were employed to produce an effective and cost-effective platform for the immobilization of the DNA and can be extended to design low-cost biosensors for the detection of the other plant pathogens.
Collapse
Affiliation(s)
- Kritika Rana
- Amity Institute of Nanotechnology, Amity University Uttar Pradesh, Noida 201303, UP, India
| | - Jagjiwan Mittal
- Amity Institute of Nanotechnology, Amity University Uttar Pradesh, Noida 201303, UP, India
| | - Jagriti Narang
- Amity Institute of Nanotechnology, Amity University Uttar Pradesh, Noida 201303, UP, India
- Current address: Department of Biotechnology, Jamia Hamdard, New Delhi 110062, UP, India
| | - Annu Mishra
- Amity Institute of Nanotechnology, Amity University Uttar Pradesh, Noida 201303, UP, India
| | - Ramesh Namdeo Pudake
- Amity Institute of Nanotechnology, Amity University Uttar Pradesh, Noida 201303, UP, India
| |
Collapse
|
36
|
Colozza N, Kehe K, Popp T, Steinritz D, Moscone D, Arduini F. Paper-based electrochemical sensor for on-site detection of the sulphur mustard. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:25069-25080. [PMID: 29934830 DOI: 10.1007/s11356-018-2545-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Accepted: 06/13/2018] [Indexed: 06/08/2023]
Abstract
Herein, we report a novel paper-based electrochemical sensor for on-site detection of sulphur mustards. This sensor was conceived combining office paper-based electrochemical sensor with choline oxidase enzyme to deliver a sustainable sensing tool. The mustard agent detection relies on the evaluation of inhibition degree of choline oxidase, which is reversibly inhibited by sulphur mustards, by measuring the enzymatic by-product H2O2 in chronoamperometric mode. A nanocomposite constituted of Prussian Blue nanoparticles and Carbon Black was used as working electrode modifier to improve the electroanalytical performances. This bioassay was successfully applied for the measurement of a sulphur mustard, Yprite, obtaining a detection limit in the millimolar range (LOD = 0.9 mM). The developed sensor, combined with a portable and easy-to-use instrumentation, can be applied for a fast and cost-effective detection of sulphur mustards.
Collapse
Affiliation(s)
- Noemi Colozza
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy
| | - Kai Kehe
- Bundeswehr Medical Academy, Medical CBRN Defense, Munich, Germany
| | - Tanja Popp
- Bundeswehr Institute of Pharmacology and Toxicology, Munich, Germany
- Walther-Straub-Institute of Pharmacology and Toxicology, Ludwig-Maximilians-Universität, Munich, Germany
| | - Dirk Steinritz
- Bundeswehr Institute of Pharmacology and Toxicology, Munich, Germany
- Walther-Straub-Institute of Pharmacology and Toxicology, Ludwig-Maximilians-Universität, Munich, Germany
| | - Danila Moscone
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy
| | - Fabiana Arduini
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy.
| |
Collapse
|
37
|
Flores-Hernandez DR, Santamaria-Garcia VJ, Melchor-Martínez EM, Sosa-Hernández JE, Parra-Saldívar R, Bonilla-Rios J. Paper and Other Fibrous Materials-A Complete Platform for Biosensing Applications. BIOSENSORS 2021; 11:128. [PMID: 33919464 PMCID: PMC8143474 DOI: 10.3390/bios11050128] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 04/02/2021] [Accepted: 04/06/2021] [Indexed: 01/22/2023]
Abstract
Paper-based analytical devices (PADs) and Electrospun Fiber-Based Biosensors (EFBs) have aroused the interest of the academy and industry due to their affordability, sensitivity, ease of use, robustness, being equipment-free, and deliverability to end-users. These features make them suitable to face the need for point-of-care (POC) diagnostics, monitoring, environmental, and quality food control applications. Our work introduces new and experienced researchers in the field to a practical guide for fibrous-based biosensors fabrication with insight into the chemical and physical interaction of fibrous materials with a wide variety of materials for functionalization and biofunctionalization purposes. This research also allows readers to compare classical and novel materials, fabrication techniques, immobilization methods, signal transduction, and readout. Moreover, the examined classical and alternative mathematical models provide a powerful tool for bioanalytical device designing for the multiple steps required in biosensing platforms. Finally, we aimed this research to comprise the current state of PADs and EFBs research and their future direction to offer the reader a full insight on this topic.
Collapse
Affiliation(s)
| | | | | | | | | | - Jaime Bonilla-Rios
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Avenida Eugenio Garza Sada 2501, Monterrey 64849, NL, Mexico; (D.R.F.-H.); (V.J.S.-G.); (E.M.M.-M.); (J.E.S.-H.); (R.P.-S.)
| |
Collapse
|
38
|
Ng JS, Hashimoto M. 3D-PAD: Paper-Based Analytical Devices with Integrated Three-Dimensional Features. BIOSENSORS 2021; 11:84. [PMID: 33802637 PMCID: PMC8002416 DOI: 10.3390/bios11030084] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 02/14/2021] [Accepted: 02/16/2021] [Indexed: 11/16/2022]
Abstract
This paper describes the use of fused deposition modeling (FDM) printing to fabricate paper-based analytical devices (PAD) with three-dimensional (3D) features, which is termed as 3D-PAD. Material depositions followed by heat reflow is a standard approach for the fabrication of PAD. Such devices are primarily two-dimensional (2D) and can hold only a limited amount of liquid samples in the device. This constraint can pose problems when the sample consists of organic solvents that have low interfacial energies with the hydrophobic barriers. To overcome this limitation, we developed a method to fabricate PAD integrated with 3D features (vertical walls as an example) by FDM 3D printing. 3D-PADs were fabricated using two types of thermoplastics. One thermoplastic had a low melting point that formed hydrophobic barriers upon penetration, and another thermoplastic had a high melting point that maintained 3D features on the filter paper without reflowing. We used polycaprolactone (PCL) for the former, and polylactic acid (PLA) for the latter. Both PCL and PLA were printed with FDM without gaps at the interface, and the resulting paper-based devices possessed hydrophobic barriers consisting of PCL seamlessly integrated with vertical features consisting of PLA. We validated the capability of 3D-PAD to hold 30 μL of solvents (ethanol, isopropyl alcohol, and acetone), all of which would not be retained on conventional PADs fabricated with solid wax printers. To highlight the importance of containing an increased amount of liquid samples, a colorimetric assay for the formation of dimethylglyoxime (DMG)-Ni (II) was demonstrated using two volumes (10 μL and 30 μL) of solvent-based dimethylglyoxime (DMG). FDM printing of 3D-PAD enabled the facile construction of 3D structures integrated with PAD, which would find applications in paper-based chemical and biological assays requiring organic solvents.
Collapse
Affiliation(s)
- James S. Ng
- Pillar of Engineering Product Development, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore;
| | - Michinao Hashimoto
- Pillar of Engineering Product Development, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore;
- SUTD-MIT International Design Centre, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore
- Digital Manufacturing and Design Centre, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore
| |
Collapse
|
39
|
Abstract
Over the past decades, microfluidic devices based on many advanced techniques have aroused widespread attention in the fields of chemical, biological, and analytical applications. Integration of microdevices with a variety of chip designs will facilitate promising functionality. Notably, the combination of microfluidics with functional nanomaterials may provide creative ideas to achieve rapid and sensitive detection of various biospecies. In this review, focused on the microfluids and microdevices in terms of their fabrication, integration, and functions, we summarize the up-to-date developments in microfluidics-based analysis of biospecies, where biomarkers, small molecules, cells, and pathogens as representative biospecies have been explored in-depth. The promising applications of microfluidic biosensors including clinical diagnosis, food safety control, and environmental monitoring are also discussed. This review aims to highlight the importance of microfluidics-based biosensors in achieving high throughput, highly sensitive, and low-cost analysis and to promote microfluidics toward a wider range of applications.
Collapse
Affiliation(s)
- Yanlong Xing
- Key Laboratory of Emergency and Trauma, Ministry of Education, Key Laboratory of Hainan Trauma and Disaster Rescue, The First Affiliated Hospital of Hainan Medical University, College of Pharmacy, Institute of Functional Materials and Molecular Imaging, College of Emergency and Trauma, Hainan Medical University, Haikou 571199, China
| | - Linlu Zhao
- Key Laboratory of Emergency and Trauma, Ministry of Education, Key Laboratory of Hainan Trauma and Disaster Rescue, The First Affiliated Hospital of Hainan Medical University, College of Pharmacy, Institute of Functional Materials and Molecular Imaging, College of Emergency and Trauma, Hainan Medical University, Haikou 571199, China
| | - Ziyi Cheng
- Key Laboratory of Emergency and Trauma, Ministry of Education, Key Laboratory of Hainan Trauma and Disaster Rescue, The First Affiliated Hospital of Hainan Medical University, College of Pharmacy, Institute of Functional Materials and Molecular Imaging, College of Emergency and Trauma, Hainan Medical University, Haikou 571199, China
| | - Chuanzhu Lv
- Key Laboratory of Emergency and Trauma, Ministry of Education, Key Laboratory of Hainan Trauma and Disaster Rescue, The First Affiliated Hospital of Hainan Medical University, College of Pharmacy, Institute of Functional Materials and Molecular Imaging, College of Emergency and Trauma, Hainan Medical University, Haikou 571199, China
| | - Feifei Yu
- Key Laboratory of Emergency and Trauma, Ministry of Education, Key Laboratory of Hainan Trauma and Disaster Rescue, The First Affiliated Hospital of Hainan Medical University, College of Pharmacy, Institute of Functional Materials and Molecular Imaging, College of Emergency and Trauma, Hainan Medical University, Haikou 571199, China
| | - Fabiao Yu
- Key Laboratory of Emergency and Trauma, Ministry of Education, Key Laboratory of Hainan Trauma and Disaster Rescue, The First Affiliated Hospital of Hainan Medical University, College of Pharmacy, Institute of Functional Materials and Molecular Imaging, College of Emergency and Trauma, Hainan Medical University, Haikou 571199, China
| |
Collapse
|
40
|
Abdelrahman MS, Khattab TA, Kamel S. Hydrazone‐Based Supramolecular Organogel for Selective Chromogenic Detection of Organophosphorus Nerve Agent Mimic. ChemistrySelect 2021. [DOI: 10.1002/slct.202004850] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Meram S. Abdelrahman
- Dyeing Printing and Auxiliaries Department National Research Centre Cairo 12622 Egypt
| | - Tawfik A. Khattab
- Dyeing Printing and Auxiliaries Department National Research Centre Cairo 12622 Egypt
| | - Samir Kamel
- Chemical Industries Research Division National Research Centre Cairo 12622 Egypt
| |
Collapse
|
41
|
Costa-Rama E, Fernández-Abedul MT. Paper-Based Screen-Printed Electrodes: A New Generation of Low-Cost Electroanalytical Platforms. BIOSENSORS 2021; 11:51. [PMID: 33669316 PMCID: PMC7920281 DOI: 10.3390/bios11020051] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/20/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
Abstract
Screen-printed technology has helped considerably to the development of portable electrochemical sensors since it provides miniaturized but robust and user-friendly electrodes. Moreover, this technology allows to obtain very versatile transducers, not only regarding their design, but also their ease of modification. Therefore, in the last decades, the use of screen-printed electrodes (SPEs) has exponentially increased, with ceramic as the main substrate. However, with the growing interest in the use of cheap and widely available materials as the basis of analytical devices, paper or other low-cost flat materials have become common substrates for SPEs. Thus, in this revision, a comprehensive overview on paper-based SPEs used for analytical proposes is provided. A great variety of designs is reported, together with several examples to illustrate the main applications.
Collapse
|
42
|
Sardini E, Serpelloni M, Tonello S. Printed Electrochemical Biosensors: Opportunities and Metrological Challenges. BIOSENSORS 2020; 10:E166. [PMID: 33158129 PMCID: PMC7694196 DOI: 10.3390/bios10110166] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 10/30/2020] [Accepted: 11/02/2020] [Indexed: 12/14/2022]
Abstract
Printed electrochemical biosensors have recently gained increasing relevance in fields ranging from basic research to home-based point-of-care. Thus, they represent a unique opportunity to enable low-cost, fast, non-invasive and/or continuous monitoring of cells and biomolecules, exploiting their electrical properties. Printing technologies represent powerful tools to combine simpler and more customizable fabrication of biosensors with high resolution, miniaturization and integration with more complex microfluidic and electronics systems. The metrological aspects of those biosensors, such as sensitivity, repeatability and stability, represent very challenging aspects that are required for the assessment of the sensor itself. This review provides an overview of the opportunities of printed electrochemical biosensors in terms of transducing principles, metrological characteristics and the enlargement of the application field. A critical discussion on metrological challenges is then provided, deepening our understanding of the most promising trends in order to overcome them: printed nanostructures to improve the limit of detection, sensitivity and repeatability; printing strategies to improve organic biosensor integration in biological environments; emerging printing methods for non-conventional substrates; microfluidic dispensing to improve repeatability. Finally, an up-to-date analysis of the most recent examples of printed electrochemical biosensors for the main classes of target analytes (live cells, nucleic acids, proteins, metabolites and electrolytes) is reported.
Collapse
Affiliation(s)
- Emilio Sardini
- Department of Information Engineering, University of Brescia, Via Branze 38, 25123 Brescia, Italy; (E.S.); (M.S.)
| | - Mauro Serpelloni
- Department of Information Engineering, University of Brescia, Via Branze 38, 25123 Brescia, Italy; (E.S.); (M.S.)
| | - Sarah Tonello
- Department of Information Engineering, University of Padova, Via Gradenigo 6, 35131 Padova, Italy
| |
Collapse
|
43
|
Shen Y, Modha S, Tsutsui H, Mulchandani A. An origami electrical biosensor for multiplexed analyte detection in body fluids. Biosens Bioelectron 2020; 171:112721. [PMID: 33091685 DOI: 10.1016/j.bios.2020.112721] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 10/08/2020] [Accepted: 10/10/2020] [Indexed: 12/14/2022]
Abstract
We developed an affordable, highly sensitive, and specific paper-based microfluidic platform for fast multiplexed detections of important biomarkers in various body fluids, including urine, saliva, serum, and whole blood. The sensor array consisted of five individual sensing channels with various functionalities that only required a micro liter-sized sample, which was equally split into aliquots by the built-in paper microfluidics. We achieved the individual functionalizations of various bioreceptors by employing the use of wax barriers and 'paper bridges' in an easy and low-cost manner. Pyrene carboxylic acid-modified single-walled carbon nanotubes (PCA/SWNTs) were deposited by quantitative inkjet printing with an optimal 3-dimensional semiconductor density on a paper substrate. Multiple antibodies were immobilized onto the SWNTs surface for highly sensitive and specific field-effect transistor (FET)/chemiresistor (CR) biosensors. We explored the optimal sensing conditions for the paper-based CR biosensor to achieve high sensitivities and specificities towards the target biomarker proteins (human serum albumin (HSA) and human immunoglobulin G (HIgG)) and achieved an ultralow detectable concentration of HSA and HIgG at 1.5 pM. Besides, origami folding was employed to simplify the fabrication process further. The sensing platform described in this work was cost-effective, semi-automated, and user-friendly. It demonstrated the capability of having multiple sensing functions in one paper-based microfluidic sensing platform. It envisioned the potential of a point-of-care device with full-analysis for practical diagnostics in an ASSURED (Affordable, Sensitive, Specific, User-friendly, Rapid and robust, Equipment-free and Deliverable to end-users) fashion for a quick test of targets of interest.
Collapse
Affiliation(s)
- Yu Shen
- Department of Chemical and Environmental Engineering, University of California, Riverside, Riverside, CA, 92521, USA
| | - Sidharth Modha
- Department of Bioengineering, University of California, Riverside, Riverside, CA, 92521, USA
| | - Hideaki Tsutsui
- Department of Bioengineering, University of California, Riverside, Riverside, CA, 92521, USA; Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, 92521, USA; Stem Cell Center, University of California, Riverside, Riverside, CA, 92521, USA
| | - Ashok Mulchandani
- Department of Chemical and Environmental Engineering, University of California, Riverside, Riverside, CA, 92521, USA; Center for Environmental Research and Technology (CE-CERT), University of California, Riverside, Riverside, CA, 92507, USA.
| |
Collapse
|
44
|
Liu M, Zhao Y, Monshat H, Tang Z, Wu Z, Zhang Q, Lu M. An IoT-enabled paper sensor platform for real-time analysis of isothermal nucleic acid amplification tests. Biosens Bioelectron 2020; 169:112651. [PMID: 33002794 DOI: 10.1016/j.bios.2020.112651] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 09/02/2020] [Accepted: 09/23/2020] [Indexed: 12/26/2022]
Abstract
Paper-based sensors can be exploited to develop low-cost, disposable, and rapid assays for the detection of a large variety of analytes. We report a paper-based sensor system for a point-of-care (POC) nucleic acid amplification test that can quantitatively detect multiple genes from different pathogens. The POC system combines a paper sensor chip and a portable instrument, which is built on an Internet of Things (IoT) platform. The paper-based sensor provides the functions of reagent storage, sample transportation, and nucleic acid amplification. The IoT instrument uses an Arduino microcontroller to control temperature, collect fluorescence images, and store the data in cloud storage via a WiFi network. A compact fluorescence reader was designed to measure fluorescence images of the amplicons during a loop-mediated isothermal amplification reaction in real-time. The real-time detection capability enables the quantitative analysis of target genes. The results show that the paper-based sensor cam distinguish multiple genes of the genomic DNA extracted from Escherichia coli and Campylobacter jejuni, with the concentration as low as 2 × 103 copies/μL. The affordable instrument, in conjunction with the disposable paper sensor chip, would have a great potential for POC detections of pathogens.
Collapse
Affiliation(s)
- Mingdian Liu
- Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, 50011, USA
| | - Yuxin Zhao
- Department of Chemical and Biological Engineering, Iowa State University, Ames, IA, 50011, USA
| | - Hosein Monshat
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA
| | - Zheyuan Tang
- Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, 50011, USA
| | - Zuowei Wu
- Department of Veterinary Microbiology and Preventive Medicine, Iowa State University, Ames, IA, 50011, USA
| | - Qijing Zhang
- Department of Veterinary Microbiology and Preventive Medicine, Iowa State University, Ames, IA, 50011, USA
| | - Meng Lu
- Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, 50011, USA; Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA.
| |
Collapse
|
45
|
Chu T, Chu J, Gao B, He B. Modern evolution of paper-based analytical devices for wearable use: from disorder to order. Analyst 2020; 145:5388-5399. [PMID: 32700700 DOI: 10.1039/d0an00994f] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Paper devices have attracted great attention for their rapid development in multiple fields, such as life sciences, biochemistry, and materials science. When manufacturing paper chips, flexible materials, such as cellulose paper or other porous flexible membranes, can offer several advantages in terms of their flexibility, lightweight, low cost, safety and wearability. However, traditional cellulose paper sheets with chaotic cellulose fiber constitutions do not have special structures and optical characteristics, leading to poor repeatability and low sensitivity during biochemical sensing, limiting their wide application. Recent evidence showed that the addition of ordered structure provides a promising method for manufacturing intelligent flexible devices, making traditional flexible devices with multiple functions (microfluidics, motion detection and optical display). There is an urgent need for an overall summary of the evolution of paper devices so that readers can fully understand the field. Hence, in this review, we summarized the latest developments in intelligent paper devices, starting with the fabrication of paper and smart flexible paper devices, in the fields of biology, chemistry, electronics, etc. First, we outlined the manufacturing methods and applications of both traditional cellulose paper devices and modern smart devices based on pseudopaper (order paper). Then, considering different materials, such as cellulose, nitrocellulose, nature sourced photonic crystals (photonic crystals sourced from nature directly) and artificial photonic crystals, we summarized a new type of smart flexible device containing an ordered structure. Next, the applications of paper devices in biochemical sensing, wearable sensing, and cross-scale sensing were discussed. Finally, we summarized the development direction of this field. The aim of this review is to take an integral cognition approach to the development of smart flexible paper devices in multiple fields and promote communications between materials science, biology, chemistry and electrical science.
Collapse
Affiliation(s)
- Tianshu Chu
- School of Pharmaceutical Sciences, Nanjing Tech University, Nanjing 211816, China.
| | | | | | | |
Collapse
|
46
|
Ng JS, Hashimoto M. Fabrication of paper microfluidic devices using a toner laser printer. RSC Adv 2020; 10:29797-29807. [PMID: 35518222 PMCID: PMC9056319 DOI: 10.1039/d0ra04301j] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 07/23/2020] [Indexed: 12/23/2022] Open
Abstract
This paper describes a method to fabricate microfluidic paper-based analytical devices (μPADs) using a toner laser printer. Multiple methods have been reported for the fabrication of μPADs for point-of-care diagnostics and environmental monitoring. Despite successful demonstrations, however, existing fabrication methods depend on particular printers, in-house instruments, and synthetic materials. In particular, recent discontinuation of the solid wax printer has made it difficult to fabricate μPADs with readily available instruments. Herein we reported the fabrication of μPADs using the most widely available type of printer: a toner laser printer. Heating of printed toner at 200 °C allowed the printed toner to reflow, and the spreading of the hydrophobic polymer through the filter paper was characterized. Using the developed μPADs, we conducted model colorimetric assays for glucose and bovine serum albumin (BSA). We found that heating of filter paper at 200 °C for 60 min caused the pyrolysis of cellulose in the paper. The pyrolysis resulted in the formation of aldehydes that could interfere with molecular assays involving redox reactions. To overcome this problem, we confirmed that the removal of the aldehyde could be readily achieved by washing the μPADs with aqueous bleach. Overall, the developed fabrication method should be compatible with most toner laser printers and will make μPADs accessible in resource-limited circumstances.
Collapse
Affiliation(s)
- James S Ng
- Pillar of Engineering Product Development, Singapore University of Technology and Design 8 Somapah Road Singapore 487372 Singapore +65 6499 4867
| | - Michinao Hashimoto
- Pillar of Engineering Product Development, Singapore University of Technology and Design 8 Somapah Road Singapore 487372 Singapore +65 6499 4867
- SUTD-MIT International Design Centre, Singapore University of Technology and Design 8 Somapah Road Singapore 487372 Singapore
- Digital Manufacturing and Design Centre, Singapore University of Technology and Design 8 Somapah Road Singapore 487372 Singapore
| |
Collapse
|
47
|
Fabrication of Bioprobe Self-Assembled on Au-Te Nanoworm Structure for SERS Biosensor. MATERIALS 2020; 13:ma13143234. [PMID: 32708092 PMCID: PMC7412440 DOI: 10.3390/ma13143234] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 07/17/2020] [Accepted: 07/17/2020] [Indexed: 11/16/2022]
Abstract
In the present study, we propose a novel biosensor platform using a gold-tellurium (Au-Te) nanoworm structure through surface-enhanced Raman spectroscopy (SERS). Au-Tenanoworm was synthesized by spontaneous galvanic replacement of sacrificial Te nanorods templated with Au (III) cations under ambient conditions. The fabricated Au-Te nanoworm exhibited an interconnected structure of small spherical nanoparticles and was found to be effective at enhancing Raman scattering. The Au-Te nanoworm-immobilized substrate exhibited the ability to detect thyroxine using an aptamer-tagged DNA three-way junction (3WJ) and glycoprotein 120 (GP120) human immunodeficiency virus (HIV) using an antibody. The modified substrates were investigated by scanning electron microscopy and atomic force microscopy (AFM). The optimal Au-Te nanoworm concentration and immobilization time for the thyroxine biosensor platform were further determined by SERS experimentation. Thus, the present study showed that the Au-Te nanoworm structure could be applied to various biosensor platforms.
Collapse
|
48
|
Yáñez-Sedeño P, Campuzano S, Pingarrón JM. Screen-Printed Electrodes: Promising Paper and Wearable Transducers for (Bio)Sensing. BIOSENSORS 2020; 10:E76. [PMID: 32660011 PMCID: PMC7400178 DOI: 10.3390/bios10070076] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 07/05/2020] [Accepted: 07/07/2020] [Indexed: 12/18/2022]
Abstract
Screen-printing technology has revolutionized many fields, including that of electrochemical biosensing. Due to their current relevance, this review, unlike other papers, discusses the relevant aspects of electrochemical biosensors manufactured using this technology in connection to both paper substrates and wearable formats. The main trends, advances, and opportunities provided by these types of devices, with particular attention to the environmental and biomedical fields, are addressed along with illustrative fundamentals and applications of selected representative approaches from the recent literature. The main challenges and future directions to tackle in this research area are also pointed out.
Collapse
Affiliation(s)
- Paloma Yáñez-Sedeño
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (S.C.); (J.M.P.)
| | | | | |
Collapse
|
49
|
Sustainable materials for the design of forefront printed (bio)sensors applied in agrifood sector. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115909] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
50
|
Colozza N, Sassolini A, Agosta L, Bonfanti A, Hermansson K, Arduini F. A Paper‐Based Potentiometric Sensor for Solid Samples: Corrosion Evaluation of Reinforcements Embedded in Concrete Structures as a Case Study. ChemElectroChem 2020. [DOI: 10.1002/celc.202000330] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Noemi Colozza
- Dipartimento di Scienze e Tecnologie Chimiche Università di Roma Tor Vergata Via della Ricerca Scientifica 00133 Rome Italy
| | | | - Lorenzo Agosta
- Department of Chemistry-Ångström /Uppsala University Box 538 S-75121 Uppsala Sweden
| | - Alfredo Bonfanti
- Municipality of Milan – Monuments and Fountains Maintenance and Management Office
| | - Kersti Hermansson
- Department of Chemistry-Ångström /Uppsala University Box 538 S-75121 Uppsala Sweden
| | - Fabiana Arduini
- Dipartimento di Scienze e Tecnologie Chimiche Università di Roma Tor Vergata Via della Ricerca Scientifica 00133 Rome Italy
- SENSE4MED via Renato Rascel 30 00128 Rome Italy
| |
Collapse
|