1
|
Song J, Liu H, Zhao Z, Lin P, Yan F. Flexible Organic Transistors for Biosensing: Devices and Applications. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2300034. [PMID: 36853083 DOI: 10.1002/adma.202300034] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 02/20/2023] [Indexed: 06/18/2023]
Abstract
Flexible and stretchable biosensors can offer seamless and conformable biological-electronic interfaces for continuously acquiring high-fidelity signals, permitting numerous emerging applications. Organic thin film transistors (OTFTs) are ideal transducers for flexible and stretchable biosensing due to their soft nature, inherent amplification function, biocompatibility, ease of functionalization, low cost, and device diversity. In consideration of the rapid advances in flexible-OTFT-based biosensors and their broad applications, herein, a timely and comprehensive review is provided. It starts with a detailed introduction to the features of various OTFTs including organic field-effect transistors and organic electrochemical transistors, and the functionalization strategies for biosensing, with a highlight on the seminal work and up-to-date achievements. Then, the applications of flexible-OTFT-based biosensors in wearable, implantable, and portable electronics, as well as neuromorphic biointerfaces are detailed. Subsequently, special attention is paid to emerging stretchable organic transistors including planar and fibrous devices. The routes to impart stretchability, including structural engineering and material engineering, are discussed, and the implementations of stretchable organic transistors in e-skin and smart textiles are included. Finally, the remaining challenges and the future opportunities in this field are summarized.
Collapse
Affiliation(s)
- Jiajun Song
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, 999077, P. R. China
| | - Hong Liu
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, 999077, P. R. China
| | - Zeyu Zhao
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, 999077, P. R. China
| | - Peng Lin
- Shenzhen Key Laboratory of Special Functional Materials and Guangdong Research Center for Interfacial Engineering of Functional Materials, College of Materials Science and Engineering, Shenzhen University, Shenzhen, 518060, P. R. China
| | - Feng Yan
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, 999077, P. R. China
- Research Institute of Intelligent Wearable Systems, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, 999077, P. R. China
| |
Collapse
|
2
|
Jiang X, Shi C, Wang Z, Huang L, Chi L. Healthcare Monitoring Sensors Based on Organic Transistors: Surface/Interface Strategy and Performance. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2308952. [PMID: 37951211 DOI: 10.1002/adma.202308952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 10/16/2023] [Indexed: 11/13/2023]
Abstract
Organic transistors possess inherent advantages such as flexibility, biocompatibility, customizable chemical structures, solution-processability, and amplifying capabilities, making them highly promising for portable healthcare sensor applications. Through convenient and diverse modifications at the material and device surfaces or interfaces, organic transistors allow for a wide range of sensor applications spanning from chemical and biological to physical sensing. In this comprehensive review, the surface and interface engineering aspect associated with four types of typical healthcare sensors is focused. The device operation principles and sensing mechanisms are systematically analyzed and highlighted, and particularly surface/interface functionalization strategies that contribute to the enhancement of sensing performance are focused. An outlook and perspective on the critical issues and challenges in the field of healthcare sensing using organic transistors are provided as well.
Collapse
Affiliation(s)
- Xingyu Jiang
- Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, 199 Ren'ai Road, Suzhou, Jiangsu, 215123, P. R. China
| | - Cheng Shi
- Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, 199 Ren'ai Road, Suzhou, Jiangsu, 215123, P. R. China
| | - Zi Wang
- Suzhou Laboratory, 388 Ruoshui Road, Suzhou, 215123, P. R. China
| | - Lizhen Huang
- Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, 199 Ren'ai Road, Suzhou, Jiangsu, 215123, P. R. China
| | - Lifeng Chi
- Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, 199 Ren'ai Road, Suzhou, Jiangsu, 215123, P. R. China
| |
Collapse
|
3
|
Gadroy C, Boukraa R, Battaglini N, Le Derf F, Mofaddel N, Vieillard J, Piro B. An Electrolyte-Gated Graphene Field-Effect Transistor for Detection of Gadolinium(III) in Aqueous Media. BIOSENSORS 2023; 13:363. [PMID: 36979575 PMCID: PMC10046572 DOI: 10.3390/bios13030363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/04/2023] [Revised: 02/27/2023] [Accepted: 03/06/2023] [Indexed: 06/18/2023]
Abstract
In this work, an electrolyte-gated graphene field-effect transistor is developed for Gd3+ ion detection in water. The source and drain electrodes of the transistor are fabricated by photolithography on polyimide, while the graphene channel is obtained by inkjet-printing a graphene oxide ink subsequently electro-reduced to give reduced graphene oxide. The Gd3+-selective ligand DOTA is functionalized by an alkyne linker to be grafted by click chemistry on a gold electrode without losing its affinity for Gd3+. The synthesis route is fully described, and the ligand, the linker and the functionalized surface are characterized by electrochemical analysis and spectroscopy. The as functionalized electrode is used as gate in the graphene transistor so to modulate the source-drain current as a function of its potential, which is itself modulated by the concentration of Gd3+captured on the gate surface. The obtained sensor is able to quantify Gd3+ even in a sample containing several other potentially interfering ions such as Ni2+, Ca2+, Na+ and In3+. The quantification range is from 1 pM to 10 mM, with a sensitivity of 20 mV dec-1 expected for a trivalent ion. This paves the way for Gd3+ quantification in hospital or industrial wastewater.
Collapse
Affiliation(s)
- Charlène Gadroy
- Université de Rouen-Normandie, Campus d’Evreux, UMR-CNRS 6014, F-27000 Evreux, France
| | - Rassen Boukraa
- Université Paris Cité, CNRS, ITODYS, F-75013 Paris, France
| | | | - Franck Le Derf
- Université de Rouen-Normandie, Campus d’Evreux, UMR-CNRS 6014, F-27000 Evreux, France
| | - Nadine Mofaddel
- Université de Rouen-Normandie, Campus d’Evreux, UMR-CNRS 6014, F-27000 Evreux, France
| | - Julien Vieillard
- Université de Rouen-Normandie, Campus d’Evreux, UMR-CNRS 6014, F-27000 Evreux, France
| | - Benoît Piro
- Université Paris Cité, CNRS, ITODYS, F-75013 Paris, France
| |
Collapse
|
4
|
Electrolyte-gated organic field-effect transistors based on 2,6-dioctyltetrathienoacene as a convenient platform for fabrication of liquid biosensors. Russ Chem Bull 2022. [DOI: 10.1007/s11172-022-3635-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
5
|
Cao BP, Dai C, Wang X, Xiao Q, Wei D. Ultrasensitive and Regenerative Transistor Sensor Based on Dynamic Covalent Chemistry. SENSORS (BASEL, SWITZERLAND) 2022; 22:6947. [PMID: 36146305 PMCID: PMC9505547 DOI: 10.3390/s22186947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/14/2022] [Revised: 09/10/2022] [Accepted: 09/12/2022] [Indexed: 06/16/2023]
Abstract
Field-effect transistor (FET) sensors require not only high sensitivity but also excellent regeneration ability before widespread applications are possible. Although some regenerative FETs have been reported, their lowest limit of detection (LoD) barely achieves 10-15 mol L-1. Here, we develop a graphene FET with a regenerative sensing interface based on dynamic covalent chemistry (DCvC). The LoD down to 5.0 × 10-20 mol L-1 remains even after 10 regenerative cycles, around 4-5 orders of magnitude lower than existing transistor sensors. Owing to its ultra-sensitivity, regeneration ability, and advantages such as simplicity, low cost, label-free and real-time response, the FET sensor based on DCvC is valuable in applications such as medical diagnosis, environment monitoring, etc.
Collapse
Affiliation(s)
- Ban-Peng Cao
- Jiangxi Key Laboratory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang 330013, China
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200433, China
| | - Changhao Dai
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200433, China
| | - Xuejun Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200433, China
| | - Qiang Xiao
- Jiangxi Key Laboratory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang 330013, China
| | - Dacheng Wei
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai 200433, China
| |
Collapse
|
6
|
Tran MT, Tran HV. Verbascoside extracted from Clerodendrum inerme: A natural monomer for the fabrication of a sensitive electrochemical Cu(II) sensor. JOURNAL OF CHEMICAL RESEARCH 2022. [DOI: 10.1177/17475198221096596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Verbascoside is isolated from the whole plants of the Verbenaceae family and demonstrates significant levels of bioactivity. In this work, we report on the isolation of verbascoside, a phenolic glycoside, from the stems of Clerodendrum inerme collected in Vietnam and verify its structure by comparing its spectroscopic data with those reported in the literature. Verbascoside is then applied as a monomer for the electrochemical deposition of a layer of polyverbascoside onto glassy carbon electrodes toward Cu2+ sensing. Electrochemical results demonstrate that the polyverbascoside-modified glassy carbon electrode is highly selective for Cu2+ ions compared to other evaluated ions including Ni2+ and Co2+. The developed sensor can detect Cu2+ in a concentration range from 0 to 175 μM with a sensitivity of 0.372 µA µM−1 and a limit of detection of 50 nM Cu2+ ions.
Collapse
Affiliation(s)
- Minh T Tran
- School of Chemical Engineering, Hanoi University of Science and Technology, Hanoi, Vietnam
| | - Hoang V Tran
- School of Chemical Engineering, Hanoi University of Science and Technology, Hanoi, Vietnam
| |
Collapse
|
7
|
Shao W, Shurin GV, He X, Zeng Z, Shurin MR, Star A. Cerebrospinal Fluid Leak Detection with a Carbon Nanotube-Based Field-Effect Transistor Biosensing Platform. ACS APPLIED MATERIALS & INTERFACES 2022; 14:1684-1691. [PMID: 34932323 DOI: 10.1021/acsami.1c19120] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Cerebrospinal fluid (CSF) leakage may lead to life-threatening complications if not detected promptly. However, gel electrophoresis, the gold-standard test for confirming CSF leakage by detecting beta2-transferrin (β2-Tf), requires 3-6 h and is labor-intensive. We developed a new β2-Tf detection platform for rapid identification of CSF leakage. The three-step design, which includes two steps of affinity chromatography and a rapid sensing step using a semiconductor-enriched single-walled carbon nanotube field-effect transistor (FET) sensor, circumvented the lack of selectivity that antitransferrin antibody exhibits for transferrin isoforms and markedly shortened the detection time. Furthermore, three different sensing configurations for the FET sensor were investigated for obtaining the optimal β2-Tf sensing results. Finally, body fluid (CSF and serum) tests employing our three-step strategy demonstrated high sensitivity, suggesting its potential to be used as a rapid diagnostic tool for CSF leakage.
Collapse
Affiliation(s)
- Wenting Shao
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Galina V Shurin
- Department of Pathology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania 15260, United States
| | - Xiaoyun He
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Zidao Zeng
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Michael R Shurin
- Department of Pathology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania 15260, United States
| | - Alexander Star
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
| |
Collapse
|
8
|
Affiliation(s)
- Liang Luo
- State Key Laboratory of Applied Organic Chemistry (SKLAOC) Lanzhou University Lanzhou P. R. China
| | - Zitong Liu
- State Key Laboratory of Applied Organic Chemistry (SKLAOC) Lanzhou University Lanzhou P. R. China
| |
Collapse
|
9
|
Abdollahiyan P, Hasanzadeh M, Pashazadeh-Panahi P, Seidi F. Application of Cys A@AuNPs supported amino acids towards rapid and selective identification of Hg(II) and Cu(II) ions in aqueous solution: An innovative microfluidic paper-based (μPADs) colorimetric sensing platform. J Mol Liq 2021. [DOI: 10.1016/j.molliq.2021.117020] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
10
|
Liu C, Ye Z, Wei X, Mao S. Recent advances in field‐effect transistor sensing strategies for fast and highly efficient analysis of heavy metal ions. ELECTROCHEMICAL SCIENCE ADVANCES 2021. [DOI: 10.1002/elsa.202100137] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Affiliation(s)
- Chengbin Liu
- College of Environmental Science and Engineering, State Key Laboratory of Pollution Control and Resource Reuse Tongji University 1239 Siping Road Shanghai 200092 China
| | - Ziwei Ye
- College of Environmental Science and Engineering, State Key Laboratory of Pollution Control and Resource Reuse Tongji University 1239 Siping Road Shanghai 200092 China
| | - Xiaojie Wei
- College of Environmental Science and Engineering, State Key Laboratory of Pollution Control and Resource Reuse Tongji University 1239 Siping Road Shanghai 200092 China
| | - Shun Mao
- College of Environmental Science and Engineering, State Key Laboratory of Pollution Control and Resource Reuse Tongji University 1239 Siping Road Shanghai 200092 China
| |
Collapse
|
11
|
Man Y, Zou WS, Kong WL, Li W, Dong W, Zhao D, Qu Q, Wang Y. Brightly blue triazine-doped carbon dots for selective determination of Cu(II) in environment and imaging in cell. J Photochem Photobiol A Chem 2021. [DOI: 10.1016/j.jphotochem.2021.113321] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
12
|
Gall JL, Vasilijević S, Battaglini N, Mattana G, Noël V, Brayner R, Piro B. Algae-functionalized hydrogel-gated organic field-effect transistor. Application to the detection of herbicides. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.137881] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
13
|
Sensi M, Berto M, Gentile S, Pinti M, Conti A, Pellacani G, Salvarani C, Cossarizza A, Bortolotti CA, Biscarini F. Anti-drug antibody detection with label-free electrolyte-gated organic field-effect transistors. Chem Commun (Camb) 2021; 57:367-370. [PMID: 33325465 DOI: 10.1039/d0cc03399e] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The efficacy of immunotherapy can be undermined by the development of an immune response against a drug/antibody mediated by anti-drug antibodies (ADAs) in treated patients. We present the first label-free EGOFET immunosensor that integrates a biological drug, Nivolumab (Opdivo©), as a specific recognition moiety to quantitatively and selectively detect ADAs against the drug. The limit of detection is 100 fM. This demonstration is a prelude to the detection of ADAs in a clinical setting in the treatment of different pathologies, and it also enables rapid screening of biological drugs for immunogenicity.
Collapse
Affiliation(s)
- Matteo Sensi
- Dipartimento di Scienze della Vita - Università di Modena e Reggio Emilia, Via Campi 103, 41125 Modena, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Timoshenko RV, Vaneev AN, Savin NA, Klyachko NL, Parkhomenko YN, Salikhov SV, Majouga AG, Gorelkin PV, Erofeev AS. Promising Approaches for Determination of Copper Ions in Biological Systems. ACTA ACUST UNITED AC 2020. [DOI: 10.1134/s1995078020020196] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
15
|
Shaposhnik PA, Zapunidi SA, Shestakov MV, Agina EV, Ponomarenko SA. Modern bio and chemical sensors and neuromorphic devices based on organic semiconductors. RUSSIAN CHEMICAL REVIEWS 2020. [DOI: 10.1070/rcr4973] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This review summarizes and highlights the current state-of-the-art of research on chemical sensors and biosensors in liquid environment and neuromorphic devices based on electrolyte-gated organic transistors with the active semiconductor layer of organic π-conjugated materials (small molecules, oligomers and polymers). The architecture and principles of operation of electrolyte-gated organic transistors and the main advantages and drawbacks of these devices are considered in detail. The criteria for the selection of organic semiconductors for these devices are presented. The causes of degradation of semiconductor layers and ways of their elimination are discussed. Examples of the use of electrolyte-gated organic transistors as bio and chemical sensors, artificial synapses and computing devices are given.
The bibliography includes 132 references.
Collapse
|
16
|
Kotuniak R, Strampraad MJF, Bossak‐Ahmad K, Wawrzyniak UE, Ufnalska I, Hagedoorn P, Bal W. Key Intermediate Species Reveal the Copper(II)-Exchange Pathway in Biorelevant ATCUN/NTS Complexes. Angew Chem Int Ed Engl 2020; 59:11234-11239. [PMID: 32267054 PMCID: PMC7383912 DOI: 10.1002/anie.202004264] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Indexed: 01/31/2023]
Abstract
The amino-terminal copper and nickel/N-terminal site (ATCUN/NTS) present in proteins and bioactive peptides exhibits high affinity towards CuII ions and have been implicated in human copper physiology. Little is known, however, about the rate and exact mechanism of formation of such complexes. We used the stopped-flow and microsecond freeze-hyperquenching (MHQ) techniques supported by steady-state spectroscopic and electrochemical data to demonstrate the formation of partially coordinated intermediate CuII complexes formed by glycyl-glycyl-histidine (GGH) peptide, the simplest ATCUN/NTS model. One of these novel intermediates, characterized by two-nitrogen coordination, t1/2 ≈100 ms at pH 6.0 and the ability to maintain the CuII /CuI redox pair is the best candidate for the long-sought reactive species in extracellular copper transport.
Collapse
Affiliation(s)
- Radosław Kotuniak
- Department of BiophysicsInstitute of Biochemistry and Biophysics Polish Academy of SciencesPawińskiego 5a02-106WarsawPoland
| | - Marc J. F. Strampraad
- Department of BiotechnologyDelft University of TechnologyVan der Maasweg 92629HZDelftThe Netherlands
| | - Karolina Bossak‐Ahmad
- Department of BiophysicsInstitute of Biochemistry and Biophysics Polish Academy of SciencesPawińskiego 5a02-106WarsawPoland
| | - Urszula E. Wawrzyniak
- Chair of Medical BiotechnologyFaculty of ChemistryWarsaw University of TechnologyNoakowskiego 300-664WarsawPoland
| | - Iwona Ufnalska
- Chair of Medical BiotechnologyFaculty of ChemistryWarsaw University of TechnologyNoakowskiego 300-664WarsawPoland
| | - Peter‐Leon Hagedoorn
- Department of BiotechnologyDelft University of TechnologyVan der Maasweg 92629HZDelftThe Netherlands
| | - Wojciech Bal
- Department of BiophysicsInstitute of Biochemistry and Biophysics Polish Academy of SciencesPawińskiego 5a02-106WarsawPoland
| |
Collapse
|
17
|
Kotuniak R, Strampraad MJF, Bossak‐Ahmad K, Wawrzyniak UE, Ufnalska I, Hagedoorn P, Bal W. Key Intermediate Species Reveal the Copper(II)‐Exchange Pathway in Biorelevant ATCUN/NTS Complexes. Angew Chem Int Ed Engl 2020. [DOI: 10.1002/ange.202004264] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Radosław Kotuniak
- Department of Biophysics Institute of Biochemistry and Biophysics Polish Academy of Sciences Pawińskiego 5a 02-106 Warsaw Poland
| | - Marc J. F. Strampraad
- Department of Biotechnology Delft University of Technology Van der Maasweg 9 2629 HZ Delft The Netherlands
| | - Karolina Bossak‐Ahmad
- Department of Biophysics Institute of Biochemistry and Biophysics Polish Academy of Sciences Pawińskiego 5a 02-106 Warsaw Poland
| | - Urszula E. Wawrzyniak
- Chair of Medical Biotechnology Faculty of Chemistry Warsaw University of Technology Noakowskiego 3 00-664 Warsaw Poland
| | - Iwona Ufnalska
- Chair of Medical Biotechnology Faculty of Chemistry Warsaw University of Technology Noakowskiego 3 00-664 Warsaw Poland
| | - Peter‐Leon Hagedoorn
- Department of Biotechnology Delft University of Technology Van der Maasweg 9 2629 HZ Delft The Netherlands
| | - Wojciech Bal
- Department of Biophysics Institute of Biochemistry and Biophysics Polish Academy of Sciences Pawińskiego 5a 02-106 Warsaw Poland
| |
Collapse
|
18
|
Le Gall J, Mouillard F, Le TN, Vu TT, Mattana G, Brayner R, Zrig S, Noël V, Piro B. Monitoring photosynthetic microorganism activity with an electrolyte-gated organic field effect transistor. Biosens Bioelectron 2020; 157:112166. [PMID: 32250936 DOI: 10.1016/j.bios.2020.112166] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 03/10/2020] [Accepted: 03/20/2020] [Indexed: 01/16/2023]
Abstract
Among organic thin film transistors (OTFTs), Organic Electrochemical Transistors (OECTs) have been extensively used for cell monitoring while Electrolyte-Gated Organic Field-Effect Transistors (EGOFETs) have never been described for that kind of application. However, EGOFETs are well adapted for this use because, as well as OECTs, they can operate directly in aqueous solutions such as cells culture media, but they offer much a higher on/off ratio which could lead to better sensitivity. As a proof of concept, we propose herein to monitor the photosynthetic activity of a cyanobacterium (Anabaena flos-aquae) contained within an EGOFET's electrolyte.
Collapse
Affiliation(s)
- Jérémy Le Gall
- Université de Paris, ITODYS, CNRS, UMR 7086, 15 Rue J-A de Baïf, F-75013, Paris, France
| | - Flavien Mouillard
- Université de Paris, ITODYS, CNRS, UMR 7086, 15 Rue J-A de Baïf, F-75013, Paris, France
| | - Trung Ngoc Le
- Department of Advanced Materials Science and Nanotechnology (AMSN), University of Science and Technology of Hanoi (USTH), Vietnam Academy of Science and Technology (VAST), 18 Hoang Quoc Viet, Nghĩa Đô, Cầu Giấy, Hanoi, Viet Nam
| | - Thi Thu Vu
- Department of Advanced Materials Science and Nanotechnology (AMSN), University of Science and Technology of Hanoi (USTH), Vietnam Academy of Science and Technology (VAST), 18 Hoang Quoc Viet, Nghĩa Đô, Cầu Giấy, Hanoi, Viet Nam
| | - Giorgio Mattana
- Université de Paris, ITODYS, CNRS, UMR 7086, 15 Rue J-A de Baïf, F-75013, Paris, France
| | - Roberta Brayner
- Université de Paris, ITODYS, CNRS, UMR 7086, 15 Rue J-A de Baïf, F-75013, Paris, France
| | - Samia Zrig
- Université de Paris, ITODYS, CNRS, UMR 7086, 15 Rue J-A de Baïf, F-75013, Paris, France
| | - Vincent Noël
- Université de Paris, ITODYS, CNRS, UMR 7086, 15 Rue J-A de Baïf, F-75013, Paris, France.
| | - B Piro
- Université de Paris, ITODYS, CNRS, UMR 7086, 15 Rue J-A de Baïf, F-75013, Paris, France.
| |
Collapse
|
19
|
Synhaivska O, Mermoud Y, Baghernejad M, Alshanski I, Hurevich M, Yitzchaik S, Wipf M, Calame M. Detection of Cu 2+ Ions with GGH Peptide Realized with Si-Nanoribbon ISFET. SENSORS 2019; 19:s19184022. [PMID: 31540412 PMCID: PMC6766833 DOI: 10.3390/s19184022] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 08/29/2019] [Accepted: 09/12/2019] [Indexed: 12/19/2022]
Abstract
The presence of heavy metal ions such as copper in the human body at certain concentrations and specific conditions can lead to the development of different diseases. The currently available analytical detection methods remain expensive, time-consuming, and often require sample pre-treatment. The development of specific and quantitative, easy-in-operation, and cost-effective devices, capable of monitoring the level of Cu2+ ions in environmental and physiological media, is necessary. We use silicon nanoribbon (SiNR) ion-sensitive field effect transistor (ISFET) devices modified with a Gly-Gly-His peptide for the detection of copper ions in a large concentration range. The specific binding of copper ions causes a conformational change of the ligand, and a deprotonation of secondary amine groups. By performing differential measurements, we gain a deeper insight into the details of the ion-ligand interaction. We highlight in particular the importance of considering non-specific interactions to explain the sensors' response.
Collapse
Affiliation(s)
- Olena Synhaivska
- Transport at Nanoscale Interfaces Laboratory, Empa-Swiss Federal Laboratories for Materials Science and Technology, Ueberlandstrasse 129, CH-8600 Duebendorf, Switzerland.
- Department of Physics, University of Basel, Klingelbergstrasse 82, CH-4056 Basel, Switzerland.
| | - Yves Mermoud
- Transport at Nanoscale Interfaces Laboratory, Empa-Swiss Federal Laboratories for Materials Science and Technology, Ueberlandstrasse 129, CH-8600 Duebendorf, Switzerland.
- Department of Physics, University of Basel, Klingelbergstrasse 82, CH-4056 Basel, Switzerland.
| | - Masoud Baghernejad
- Transport at Nanoscale Interfaces Laboratory, Empa-Swiss Federal Laboratories for Materials Science and Technology, Ueberlandstrasse 129, CH-8600 Duebendorf, Switzerland.
| | - Israel Alshanski
- Institute of Chemistry, The Hebrew University of Jerusalem, Safra Campus, Givat Ram, Jerusalem 91904, Israel.
| | - Mattan Hurevich
- Institute of Chemistry, The Hebrew University of Jerusalem, Safra Campus, Givat Ram, Jerusalem 91904, Israel.
| | - Shlomo Yitzchaik
- Institute of Chemistry, The Hebrew University of Jerusalem, Safra Campus, Givat Ram, Jerusalem 91904, Israel.
| | - Mathias Wipf
- Transport at Nanoscale Interfaces Laboratory, Empa-Swiss Federal Laboratories for Materials Science and Technology, Ueberlandstrasse 129, CH-8600 Duebendorf, Switzerland.
| | - Michel Calame
- Transport at Nanoscale Interfaces Laboratory, Empa-Swiss Federal Laboratories for Materials Science and Technology, Ueberlandstrasse 129, CH-8600 Duebendorf, Switzerland.
- Department of Physics, University of Basel, Klingelbergstrasse 82, CH-4056 Basel, Switzerland.
| |
Collapse
|
20
|
Liu N, Chen R, Wan Q. Recent Advances in Electric-Double-Layer Transistors for Bio-Chemical Sensing Applications. SENSORS 2019; 19:s19153425. [PMID: 31387221 PMCID: PMC6696065 DOI: 10.3390/s19153425] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 07/25/2019] [Accepted: 08/01/2019] [Indexed: 12/20/2022]
Abstract
As promising biochemical sensors, ion-sensitive field-effect transistors (ISFETs) are used widely in the growing field of biochemical sensing applications. Recently, a new type of field-effect transistor gated by ionic electrolytes has attracted intense attention due to the extremely strong electric-double-layer (EDL) gating effect. In such devices, the carrier density of the semiconductor channel can be effectively modulated by an ion-induced EDL capacitance at the semiconductor/electrolyte interface. With advantages of large specific capacitance, low operating voltage and sensitive interfacial properties, various EDL-based transistor (EDLT) devices have been developed for ultrasensitive portable sensing applications. In this article, we will review the recent progress of EDLT-based biochemical sensors. Starting with a brief introduction of the concepts of EDL capacitance and EDLT, we describe the material compositions and the working principle of EDLT devices. Moreover, the biochemical sensing performances of several important EDLTs are discussed in detail, including organic-based EDLTs, oxide-based EDLTs, nanomaterial-based EDLTs and neuromorphic EDLTs. Finally, the main challenges and development prospects of EDLT-based biochemical sensors are listed.
Collapse
Affiliation(s)
- Ning Liu
- Nanchang Institute of Technology, Nanchang 330099, China
- School of Electronic Science & Engineering, Nanjing University, Nanjing 210093, China
| | - Ru Chen
- Nanchang Institute of Technology, Nanchang 330099, China
| | - Qing Wan
- School of Electronic Science & Engineering, Nanjing University, Nanjing 210093, China.
| |
Collapse
|