1
|
Chew MS, Donadello K, Messina A. Editorial comment to intraoperative haemodynamic monitoring and management of adults having non-cardiac surgery: guidelines of the German society of Anaesthesiology and Intensive care medicine in collaboration with the German Association of the Scientific medical societies. J Clin Monit Comput 2024; 38:941-944. [PMID: 39060555 DOI: 10.1007/s10877-024-01203-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2024] [Accepted: 07/19/2024] [Indexed: 07/28/2024]
Affiliation(s)
- Michelle S Chew
- Department of Anaesthesia and Intensive Care, Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.
| | - Katia Donadello
- Department of Surgery, Dentistry, Gynaecology and Paediatrics, University of Verona, Verona, Italy
- Anaesthesia and Intensive Care B Unit, University Hospital Integrated Trust of Verona, Verona, Italy
| | - Antonio Messina
- Department of Anesthesia and Intensive Care Medicine, Humanitas Clinical and Research Center, Humanitas Hospital, Milan, Italy
| |
Collapse
|
2
|
Chaves RCDF, Barbas CSV, Queiroz VNF, Serpa Neto A, Deliberato RO, Pereira AJ, Timenetsky KT, Silva Júnior JM, Takaoka F, de Backer D, Celi LA, Corrêa TD. Assessment of fluid responsiveness using pulse pressure variation, stroke volume variation, plethysmographic variability index, central venous pressure, and inferior vena cava variation in patients undergoing mechanical ventilation: a systematic review and meta-analysis. Crit Care 2024; 28:289. [PMID: 39217370 PMCID: PMC11366151 DOI: 10.1186/s13054-024-05078-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Accepted: 08/24/2024] [Indexed: 09/04/2024] Open
Abstract
IMPORTANCE Maneuvers assessing fluid responsiveness before an intravascular volume expansion may limit useless fluid administration, which in turn may improve outcomes. OBJECTIVE To describe maneuvers for assessing fluid responsiveness in mechanically ventilated patients. REGISTRATION The protocol was registered at PROSPERO: CRD42019146781. INFORMATION SOURCES AND SEARCH PubMed, EMBASE, CINAHL, SCOPUS, and Web of Science were search from inception to 08/08/2023. STUDY SELECTION AND DATA COLLECTION Prospective and intervention studies were selected. STATISTICAL ANALYSIS Data for each maneuver were reported individually and data from the five most employed maneuvers were aggregated. A traditional and a Bayesian meta-analysis approach were performed. RESULTS A total of 69 studies, encompassing 3185 fluid challenges and 2711 patients were analyzed. The prevalence of fluid responsiveness was 49.9%. Pulse pressure variation (PPV) was studied in 40 studies, mean threshold with 95% confidence intervals (95% CI) = 11.5 (10.5-12.4)%, and area under the receiver operating characteristics curve (AUC) with 95% CI was 0.87 (0.84-0.90). Stroke volume variation (SVV) was studied in 24 studies, mean threshold with 95% CI = 12.1 (10.9-13.3)%, and AUC with 95% CI was 0.87 (0.84-0.91). The plethysmographic variability index (PVI) was studied in 17 studies, mean threshold = 13.8 (12.3-15.3)%, and AUC was 0.88 (0.82-0.94). Central venous pressure (CVP) was studied in 12 studies, mean threshold with 95% CI = 9.0 (7.7-10.1) mmHg, and AUC with 95% CI was 0.77 (0.69-0.87). Inferior vena cava variation (∆IVC) was studied in 8 studies, mean threshold = 15.4 (13.3-17.6)%, and AUC with 95% CI was 0.83 (0.78-0.89). CONCLUSIONS Fluid responsiveness can be reliably assessed in adult patients under mechanical ventilation. Among the five maneuvers compared in predicting fluid responsiveness, PPV, SVV, and PVI were superior to CVP and ∆IVC. However, there is no data supporting any of the above mentioned as being the best maneuver. Additionally, other well-established tests, such as the passive leg raising test, end-expiratory occlusion test, and tidal volume challenge, are also reliable.
Collapse
Affiliation(s)
- Renato Carneiro de Freitas Chaves
- Department of Intensive Care, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil.
- Department of Anesthesiology, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil.
- Department of Pneumology, Instituto do Coração (INCOR), Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil.
- MIT Critical Data, Laboratory for Computational Physiology, Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, USA.
- Department of Critical Care Medicine and Anesthesiology, Hospital Israelita Albert Einstein, Avenida Albert Einstein, 627/701, 5° Floor, São Paulo, SP, 05651-901, Brazil.
| | - Carmen Silvia Valente Barbas
- Department of Intensive Care, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
- Department of Pneumology, Instituto do Coração (INCOR), Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | - Veronica Neves Fialho Queiroz
- Department of Anesthesiology, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
- Department of Anesthesiology, Takaoka Anestesia, São Paulo, SP, Brazil
| | - Ary Serpa Neto
- Department of Intensive Care, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
- Australian and New Zealand Intensive Care Research Centre (ANZIC-RC), Melbourne, VIC, Australia
- Department of Intensive Care, Melbourne Medical School, University of Melbourne, Austin Hospital, Melbourne, Australia
| | - Rodrigo Octavio Deliberato
- MIT Critical Data, Laboratory for Computational Physiology, Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, USA
- Translational Health Intelligence and Knowledge Lab, Department of Biostatistics, Health Informatics and Data Science, University of Cincinnati, Cincinnati, OH, USA
- Division of Biomedical Informatics, Cincinnati Children's Hospital, Cincinnati, OH, USA
| | - Adriano José Pereira
- Department of Intensive Care, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
| | | | | | - Flávio Takaoka
- Department of Anesthesiology, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
- Department of Anesthesiology, Takaoka Anestesia, São Paulo, SP, Brazil
| | - Daniel de Backer
- Department of Intensive Care, CHIREC Hospitals, Université Libre de Bruxelles, Brussels, Belgium
| | - Leo Anthony Celi
- MIT Critical Data, Laboratory for Computational Physiology, Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, USA
| | | |
Collapse
|
3
|
Messina A, Caporale M, Calabrò L, Lionetti G, Bono D, Matronola GM, Brunati A, Frassanito L, Morenghi E, Antonelli M, Chew MS, Cecconi M. Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression. Crit Care 2023; 27:431. [PMID: 37940953 PMCID: PMC10631038 DOI: 10.1186/s13054-023-04706-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 10/23/2023] [Indexed: 11/10/2023] Open
Abstract
BACKGROUND Pulse pressure and stroke volume variation (PPV and SVV) have been widely used in surgical patients as predictors of fluid challenge (FC) response. Several factors may affect the reliability of these indices in predicting fluid responsiveness, such as the position of the patient, the use of laparoscopy and the opening of the abdomen or the chest, combined FC characteristics, the tidal volume (Vt) and the type of anesthesia. METHODS Systematic review and metanalysis of PPV and SVV use in surgical adult patients. The QUADAS-2 scale was used to assess the risk of bias of included studies. We adopted a metanalysis pooling of aggregate data from 5 subgroups of studies with random effects models using the common-effect inverse variance model. The area under the curve (AUC) of pooled receiving operating characteristics (ROC) curves was reported. A metaregression was performed using FC type, volume, and rate as independent variables. RESULTS We selected 59 studies enrolling 2,947 patients, with a median of fluid responders of 55% (46-63). The pooled AUC for the PPV was 0.77 (0.73-0.80), with a mean threshold of 10.8 (10.6-11.0). The pooled AUC for the SVV was 0.76 (0.72-0.80), with a mean threshold of 12.1 (11.6-12.7); 19 studies (32.2%) reported the grey zone of PPV or SVV, with a median of 56% (40-62) and 57% (46-83) of patients included, respectively. In the different subgroups, the AUC and the best thresholds ranged from 0.69 and 0.81 and from 6.9 to 11.5% for the PPV, and from 0.73 to 0.79 and 9.9 to 10.8% for the SVV. A high Vt and the choice of colloids positively impacted on PPV performance, especially among patients with closed chest and abdomen, or in prone position. CONCLUSION The overall performance of PPV and SVV in operating room in predicting fluid responsiveness is moderate, ranging close to an AUC of 0.80 only some subgroups of surgical patients. The grey zone of these dynamic indices is wide and should be carefully considered during the assessment of fluid responsiveness. A high Vt and the choice of colloids for the FC are factors potentially influencing PPV reliability. TRIAL REGISTRATION PROSPERO (CRD42022379120), December 2022. https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=379120.
Collapse
Affiliation(s)
- Antonio Messina
- Department of Anaesthesia and Intensive Care Medicine, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano - Milan, Italy.
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy.
| | - Mariagiovanna Caporale
- Department of Anesthesia and Intensive Care, Fondazione Policlinico Universitario 'A. Gemelli' IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Lorenzo Calabrò
- Department of Anaesthesia and Intensive Care Medicine, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano - Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
| | - Giulia Lionetti
- Department of Anaesthesia and Intensive Care Medicine, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano - Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
| | - Daniele Bono
- Department of Anaesthesia and Intensive Care Medicine, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano - Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
| | - Guia Margherita Matronola
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
| | - Andrea Brunati
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
| | - Luciano Frassanito
- Department of Anesthesia and Intensive Care, Fondazione Policlinico Universitario 'A. Gemelli' IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Emanuela Morenghi
- Department of Anaesthesia and Intensive Care Medicine, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano - Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
| | - Massimo Antonelli
- Department of Anesthesia and Intensive Care, Fondazione Policlinico Universitario 'A. Gemelli' IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Michelle S Chew
- Department of Anaesthesia and Intensive Care, Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Maurizio Cecconi
- Department of Anaesthesia and Intensive Care Medicine, IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano - Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072, Pieve Emanuele, Milan, Italy
| |
Collapse
|
4
|
Wu M, Dai Z, Liang Y, Liu X, Zheng X, Zhang W, Bo J. Respiratory variation in the internal jugular vein does not predict fluid responsiveness in the prone position during adolescent idiopathic scoliosis surgery: a prospective cohort study. BMC Anesthesiol 2023; 23:360. [PMID: 37932674 PMCID: PMC10626766 DOI: 10.1186/s12871-023-02313-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 10/19/2023] [Indexed: 11/08/2023] Open
Abstract
BACKGROUND Respiratory variation in the internal jugular vein (IJVV) has not shown promising results in predicting volume responsiveness in ventilated patients with low tidal volume (Vt) in prone position. We aimed to determine whether the baseline respiratory variation in the IJVV value measured by ultrasound might predict fluid responsiveness in patients with adolescent idiopathic scoliosis (AIS) undergoing posterior spinal fusion (PSF) with low Vt. METHODS According to the fluid responsiveness results, the included patients were divided into two groups: those who responded to volume expansion, denoted the responder group, and those who did not respond, denoted the non-responder group. The primary outcome was determination of the value of baseline IJVV in predicting fluid responsiveness (≥15% increases in stroke volume index (SVI) after 7 ml·kg-1 colloid administration) in patients with AIS undergoing PSF during low Vt ventilation. Secondary outcomes were estimation of the diagnostic performance of pulse pressure variation (PPV), stroke volume variation (SVV), and the combination of IJVV and PPV in predicting fluid responsiveness in this surgical setting. The ability of each parameter to predict fluid responsiveness was assessed using a receiver operating characteristic curve. RESULTS Fifty-six patients were included, 36 (64.29%) of whom were deemed fluid responsive. No significant difference in baseline IJVV was found between responders and non-responders (25.89% vs. 23.66%, p = 0.73), and no correlation was detected between baseline IJVV and the increase in SVI after volume expansion (r = 0.14, p = 0.40). A baseline IJVV greater than 32.00%, SVV greater than 14.30%, PPV greater than 11.00%, and a combination of IJVV and PPV greater than 64.00% had utility in identifying fluid responsiveness, with a sensitivity of 33.33%, 77.78%, 55.56%, and 55.56%, respectively, and a specificity of 80.00%, 50.00%, 65.00%, and 65.00%, respectively. The area under the receiver operating characteristic curve for the baseline values of IJVV, SVV, PPV, and the combination of IJVV and PPV was 0.52 (95% CI, 0.38-0.65, p=0.83), 0.54 (95% CI, 0.40-0.67, p=0.67), 0.58 (95% CI, 0.45-0.71, p=0.31), and 0.57 (95% CI, 0.43-0.71, p=0.37), respectively. CONCLUSIONS Ultrasonic-derived IJVV lacked accuracy in predicting fluid responsiveness in patients with AIS undergoing PSF during low Vt ventilation. In addition, the baseline values of PPV, SVV, and the combination of IJVV and PPV did not predict fluid responsiveness in this surgical setting. TRAIL REGISTRATION This trial was registered at www.chictr.org (ChiCTR2200064947) on 24/10/2022. All data were collected through chart review.
Collapse
Affiliation(s)
- Mimi Wu
- Department of Anesthesiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, People's Republic of China
| | - Zhao Dai
- Department of Anesthesiology, The Affiliated Yantai Yuhuangding Hospital of Qingdao University, Yantai, People's Republic of China
| | - Ying Liang
- Department of Anesthesiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, People's Republic of China
| | - Xiaojie Liu
- Department of Anesthesiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, People's Republic of China
| | - Xu Zheng
- Department of Anesthesiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, People's Republic of China
| | - Wei Zhang
- Department of Anesthesiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, People's Republic of China.
| | - Jinhua Bo
- Department of Anesthesiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, People's Republic of China.
| |
Collapse
|
5
|
de Courson H, Chadefaux G, Abel B, Georges D, Verchere E, Biais M. Ability of the Analgesia Nociception Index variations to identify a response to a volume expansion of 250 mL of crystalloids in the operating room (REVANI): a prospective observational study. BMC Anesthesiol 2023; 23:218. [PMID: 37344801 DOI: 10.1186/s12871-023-02181-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 06/15/2023] [Indexed: 06/23/2023] Open
Abstract
BACKGROUND Analgesia Nociception Index (ANI) is a device based on analysis of the R-R interval and respiratory sinus arrhythmia to assess the balance between sympathetic and parasympathetic activity. The autonomic system is directly affected by load changes. Therefore, monitoring sympathetic tone and its change could theoretically allow tracking of load changes during volume expansion. The aim of the present study was to determine whether changes in ANI are able to track the increase in stroke volume caused by volume expansion (SV). METHODS This prospective observational study included mechanically ventilated patients undergoing neurosurgery and benefiting from SV monitoring. Exclusion criteria were cardiac dysfunction, arrhythmias, beta-blockade therapy, and dysautonomia. SV was optimized by fluid administration of 250 ml of crystalloid fluid. A positive fluid increase was defined as a SV increase of 10% or more from baseline. Changes in SV and medium ANI (ANIm) were recorded before and 4 to 5 min after volume expansion. RESULTS Sixty-nine patients had 104 fluid challenges (36 positive and 68 negative). Volume expansion resulted in a greater ANI increase in responders than in nonresponders. The change in ANIm > 5 predicted fluid responsiveness with a sensitivity of 68.4% (95% CI: 67.4% to 69.5%) and a specificity of 51.2% (95% CI: 50.1% to 52.3%). The area under the receiver operating characteristic curve was 0.546 (95% CI: 0.544 to 0.549) and appeared to be affected by remifentanil dose and baseline ANI. CONCLUSION Changes in ANIm induced by fluid challenge is not able to predict fluid responsiveness in mechanically ventilated patients undergoing neurosurgery. TRIAL REGISTRATION Clinical trial registration: NCT04223414.
Collapse
Affiliation(s)
| | | | - Benjamin Abel
- Centre Hospitalier Universitaire de Bordeaux, Bordeaux, France
| | | | - Eric Verchere
- Centre Hospitalier Universitaire de Bordeaux, Bordeaux, France
| | - Matthieu Biais
- Centre Hospitalier Universitaire de Bordeaux, Bordeaux, France.
- Service d'Anesthésie-Réanimation, Groupe Hospitalier Pellegrin, Place Amélie Raba Léon, 33000, Bordeaux, France.
| |
Collapse
|
6
|
Huang H, Wu C, Shen Q, Fang Y, Xu H. Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2022; 26:20. [PMID: 35031070 PMCID: PMC8760720 DOI: 10.1186/s13054-022-03890-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 01/08/2022] [Indexed: 01/06/2023]
Abstract
Background The ability of end-tidal carbon dioxide (ΔEtCO2) for predicting fluid responsiveness has been extensively studied with conflicting results. This meta-analysis aimed to explore the value of ΔEtCO2 for predicting fluid responsiveness during the passive leg raising (PLR) test in patients with mechanical ventilation. Methods PubMed, Embase, and Cochrane Central Register of Controlled Trials were searched up to November 2021. The diagnostic odds ratio (DOR), sensitivity, and specificity were calculated. The summary receiver operating characteristic curve was estimated, and the area under the curve (AUROC) was calculated. Q test and I2 statistics were used for study heterogeneity and publication bias was assessed by Deeks’ funnel plot asymmetry test. We performed meta-regression analysis for heterogeneity exploration and sensitivity analysis for the publication bias. Results Overall, six studies including 298 patients were included in this review, of whom 149 (50%) were fluid responsive. The cutoff values of ΔEtCO2 in four studies was 5%, one was 5.8% and the other one was an absolute increase 2 mmHg. Heterogeneity between studies was assessed with an overall Q = 4.098, I2 = 51%, and P = 0.064. The pooled sensitivity and specificity for the overall population were 0.79 (95% CI 0.72–0.85) and 0.90 (95% CI 0.77–0.96), respectively. The DOR was 35 (95% CI 12–107). The pooled AUROC was 0.81 (95% CI 0.77–0.84). On meta-regression analysis, the number of patients was sources of heterogeneity. The sensitivity analysis showed that the pooled DOR ranged from 21 to 140 and the pooled AUC ranged from 0.92 to 0.96 when one study was omitted. Conclusions Though the limited number of studies included and study heterogeneity, our meta-analysis confirmed that the ΔEtCO2 performed moderately in predicting fluid responsiveness during the PLR test in patients with mechanical ventilation.
Collapse
Affiliation(s)
- Haijun Huang
- Department of Emergency, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, 310018, Zhejiang, China
| | - Chenxia Wu
- Department of Emergency, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, 310018, Zhejiang, China
| | - Qinkang Shen
- Department of Emergency, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, 310018, Zhejiang, China
| | - Yixin Fang
- Department of Emergency, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, 310018, Zhejiang, China
| | - Hua Xu
- Department of Emergency, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, 310018, Zhejiang, China.
| |
Collapse
|
7
|
Relationship between variations in cardiac output and end-tidal CO 2 after phenylephrine infusion in anaesthetised patients. Br J Anaesth 2021; 126:e174-e176. [PMID: 33674072 DOI: 10.1016/j.bja.2021.02.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 01/29/2021] [Accepted: 02/04/2021] [Indexed: 11/22/2022] Open
|