Zhou Y, Isaksson P, Persson C. An improved trabecular bone model based on Voronoi tessellation. J Mech Behav Biomed Mater 2023; 148:106172. [PMID: 37852087 DOI: 10.1016/j.jmbbm.2023.106172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 09/17/2023] [Accepted: 10/09/2023] [Indexed: 10/20/2023]
Abstract
BACKGROUND AND OBJECTIVE Accurate numerical and physical models of trabecular bone, correctly representing its complexity and variability, could be highly advantageous in the development of e.g. new bone-anchored implants due to the limited availability of real bone. Several Voronoi tessellation-based porous models have been reported in the literature, attempting to mimic the trabecular bone. However, these models have been limited to lattice rod-like structures, which are only structurally representative of very high-porosity trabecular bone. The objective of this study was to provide an improved model, more representative of trabecular bone of different porosity. METHODS Boolean operations were utilized to merge scaled Voronoi cells, thereby introducing different structural patterns, controlling porosity and to some extent anisotropy. The mechanical properties of the structures were evaluated using analytical estimations, numerical simulations, and experimental compression tests of 3D-printed versions of the structures. The capacity of the developed models to represent trabecular bone was assessed by comparing some key geometric features with trabecular bone characterized in previous studies. RESULTS The models gave the possibility to provide pore interconnectivity at relatively low porosities as well as both plate- and rod-like structures. The mechanical properties of the generated models were predictable with numerical simulations as well as an analytical approach. The permeability was found to be better than Sawbones at the same porosity. The models also showed the capability of matching e.g. some vertebral structures for key geometric features. CONCLUSIONS An improved numerical model for mimicking trabecular bone structures was successfully developed using Voronoi tessellation and Boolean operations. This is expected to benefit both computational and experimental studies by providing a more diverse and representative structure of trabecular bone.
Collapse
Affiliation(s)
- Yijun Zhou
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Box 35, Uppsala, 75121, Sweden.
| | - Per Isaksson
- Division of Applied Mechanics, Department of Materials Science and Engineering, Uppsala University, Box 35, Uppsala, 75121, Sweden.
| | - Cecilia Persson
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Box 35, Uppsala, 75121, Sweden.
| |
Collapse
|
2
|
Selection of animal bone surrogate samples for orthopaedic screw testing based on human radius CT-derived bone morphology. Med Eng Phys 2022; 103:103786. [DOI: 10.1016/j.medengphy.2022.103786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 01/26/2022] [Accepted: 03/01/2022] [Indexed: 11/17/2022]
|
3
|
Csernátony Z, Manó S, Tiba Z, Husi G, Jónás Z, Váradi T, Csámer L, Kovács ÁÉ. Critical analysis of in vitro stability testing of spinal implants and proposal for standardization. Expert Rev Med Devices 2022; 19:281-286. [PMID: 35297275 DOI: 10.1080/17434440.2022.2054331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
BACKGROUND The American Society for Testing and Materials (ASTM), considered the gold standard worldwide, requires only testing in physiological saline solution to simulate in vivo conditions in standard testing of spinal implants. RESEARCH DESIGN AND METHODS We conducted an in vitro study to identify an industrial lubricant with characteristics that are most similar to those of biologically lubricating fat, blood, and tissue fluids. The use of such a material could standardize the results of in vitro mechanical tests for better clinical applications. RESULTS Our study has shown that the lubricity of physiological saline was well below that of human soft tissues and tissue fluids, and among the motor oils, Castrol GTX3 provided a testing environment similar to that of a living organism. CONCLUSIONS With the intention of standardizing and preventing a biological hazard, we have developed a reproducible mechanical testing proposal based on our experiments, which, in addition, would allow us to avoid many misunderstandings and contingencies.
Collapse
Affiliation(s)
- Zoltán Csernátony
- University of Debrecen, Faculty of Medicine, Department of Orthopaedic Surgery, Laboratory of Biomechanics, Hungary
| | - Sándor Manó
- University of Debrecen, Faculty of Medicine, Department of Orthopaedic Surgery, Laboratory of Biomechanics, Hungary
| | - Zsolt Tiba
- Department of Aircrafts and Road Vehicles, University of Debrecen, Faculty of Engineering, Institute for Mechanical and Vehicle Engineering, Hungary
| | - Géza Husi
- Faculty of Engineering, Department of Mechatronics, University of Debrecen, Hungary
| | - Zoltán Jónás
- University of Debrecen, Faculty of Medicine, Department of Orthopaedic Surgery, Laboratory of Biomechanics, Hungary
| | - Tímea Váradi
- AC2T research GmbH, Department of Advanced Chemical Analysis, Technology and Research Center, Austria
| | - Loránd Csámer
- University of Debrecen, Faculty of Medicine, Department of Orthopaedic Surgery, Laboratory of Biomechanics, Hungary
| | - Ágnes Éva Kovács
- University of Debrecen, Faculty of Medicine, Department of Orthopaedic Surgery, Laboratory of Biomechanics, Hungary
| |
Collapse
|
4
|
Revel M, Bermond F, Duboeuf F, Mitton D, Follet H. Influence of loading conditions in finite element analysis assessed by HR-pQCT on ex vivo fracture prediction. Bone 2022; 154:116206. [PMID: 34547523 DOI: 10.1016/j.bone.2021.116206] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 09/15/2021] [Accepted: 09/15/2021] [Indexed: 12/17/2022]
Abstract
Many fractures occur in individuals with normal areal Bone Mineral Density (aBMD) measured by Dual X-ray Absorptiometry (DXA). High Resolution peripheral Quantitative Computed Tomography (HR-pQCT) allows for non-invasive evaluation of bone stiffness and strength through micro finite element (μFE) analysis at the tibia and radius. These μFE outcomes are strongly associated with fragility fractures but do not provide clear enhancement compared with DXA measurements. The objective of this study was to establish whether a change in loading conditions in standard μFE analysis assessed by HR-pQCT enhance the discrimination of low-trauma fractured radii (n = 11) from non-fractured radii (n = 16) obtained experimentally throughout a mechanical test reproducing a forward fall. Micro finite element models were created using HR-pQCT images, and linear analyses were performed using four different types of loading conditions (axial, non-axial with two orientations and torsion). No significant differences were found between the failure load assessed with the axial and non-axial models. The different loading conditions tested presented the same area under the receiver operating characteristic (ROC) curves of 0.79 when classifying radius fractures with an accuracy of 81.5%. In comparison, the area under the curve (AUC) is 0.77 from DXA-derived ultra-distal aBMD of the forearm with an accuracy of 85.2%. These results suggest that the restricted HR-pQCT scanned region seems not sensitive to loading conditions for the prediction of radius fracture risk based on ex vivo experiments (n = 27).
Collapse
Affiliation(s)
- M Revel
- Univ Lyon, Univ Claude Bernard Lyon 1, INSERM, LYOS UMR1033, F69008 Lyon, France; Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T9406, F69622 Lyon, France
| | - F Bermond
- Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T9406, F69622 Lyon, France
| | - F Duboeuf
- Univ Lyon, Univ Claude Bernard Lyon 1, INSERM, LYOS UMR1033, F69008 Lyon, France
| | - D Mitton
- Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T9406, F69622 Lyon, France
| | - H Follet
- Univ Lyon, Univ Claude Bernard Lyon 1, INSERM, LYOS UMR1033, F69008 Lyon, France.
| |
Collapse
|
5
|
Mikami K, Nemoto M, Nagura T, Nakamura M, Matsumoto M, Nakashima D. Machine Learning-Based Diagnosis in Laser Resonance Frequency Analysis for Implant Stability of Orthopedic Pedicle Screws. SENSORS 2021; 21:s21227553. [PMID: 34833628 PMCID: PMC8623959 DOI: 10.3390/s21227553] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Revised: 11/08/2021] [Accepted: 11/10/2021] [Indexed: 11/16/2022]
Abstract
Evaluation of the initial stability of implants is essential to reduce the number of implant failures of pedicle screws after orthopedic surgeries. Laser resonance frequency analysis (L-RFA) has been recently proposed as a viable diagnostic scheme in this regard. In a previous study, L-RFA was used to demonstrate the diagnosis of implant stability of monoaxial screws with a fixed head. However, polyaxial screws with movable heads are also frequently used in practice. In this paper, we clarify the characteristics of the laser-induced vibrational spectra of polyaxial screws which are required for making L-RFA diagnoses of implant stability. In addition, a novel analysis scheme of a vibrational spectrum using L-RFA based on machine learning is demonstrated and proposed. The proposed machine learning-based diagnosis method demonstrates a highly accurate prediction of implant stability (peak torque) for polyaxial pedicle screws. This achievement will contribute an important analytical method for implant stability diagnosis using L-RFA for implants with moving parts and shapes used in various clinical situations.
Collapse
Affiliation(s)
- Katsuhiro Mikami
- Faculty of Biology-Oriented Science and Technology, Kindai University, Wakayama 649-6493, Japan;
- Correspondence:
| | - Mitsutaka Nemoto
- Faculty of Biology-Oriented Science and Technology, Kindai University, Wakayama 649-6493, Japan;
| | - Takeo Nagura
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo 160-8582, Japan; (T.N.); (M.N.); (M.M.); (D.N.)
- Department of Clinical Biomechanics, Keio University School of Medicine, Tokyo 160-8582, Japan
| | - Masaya Nakamura
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo 160-8582, Japan; (T.N.); (M.N.); (M.M.); (D.N.)
| | - Morio Matsumoto
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo 160-8582, Japan; (T.N.); (M.N.); (M.M.); (D.N.)
| | - Daisuke Nakashima
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo 160-8582, Japan; (T.N.); (M.N.); (M.M.); (D.N.)
| |
Collapse
|
6
|
Nakashima D, Mikami K, Kikuchi S, Nishikino M, Kitamura T, Hasegawa N, Matsumoto M, Nakamura M, Nagura T. Laser resonance frequency analysis of pedicle screw stability: A cadaveric model bone study. J Orthop Res 2021; 39:2474-2484. [PMID: 33458845 PMCID: PMC8596623 DOI: 10.1002/jor.24983] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Revised: 12/31/2020] [Accepted: 01/11/2021] [Indexed: 02/04/2023]
Abstract
There is no evaluation method currently available to assess intraoperative pedicle screw fixation (PSF) strength. In this study, we established a laser-based resonance frequency analysis (RFA) system with high-speed, noncontact, quantitative measurements of PSF. Clinical investigations in the future can assess surgical failure risk of implants. We investigated the characteristics of the laser RFA and compared them with the conventional methods. We inserted a pedicle screw in the vertebral pedicle of human cadaver or model bone, followed by screw pull-out, peak torque, implant stability quotient (ISQ) value obtained by the magnetic dental RFA system, and fixation force of laser RFA. We compared the outcomes using best-fit linear or logarithmic approximations. For the model bone study, the resonance frequency (RF) versus peak torque/pull-out force (POF) demonstrated strong correlations using logarithmic approximation (vs. peak torque: R = 0.931, p < .001, vs. POF: R = 0.931, p < .001). RF strongly correlated with the ISQ value using linear approximation (R = 0.981, p < .001). For the cadaveric vertebrae study, the correlation coefficients between RF and the peak torque/POF were significant regardless of approximation method (peak torque: logarithmic: R = 0.716 vs. linear: R = 0.811; p < .001) (POF: logarithmic: R = 0.644 vs. linear: R = 0.548; p < .05). Thus, the results of this study revealed a constant correlation between RFA and conventional methods as a measurement validation, predicting favorable support for intraoperative PSF. RFA has the potential to be a new index for evaluating the implant fixation force.
Collapse
Affiliation(s)
- Daisuke Nakashima
- Department of Orthopedic SurgeryKeio University School of Medicine, ShinjukuTokyoJapan
| | - Katsuhiro Mikami
- Faculty of Biology‐Oriented Science and Technology, Kindai UniversityKinokawaWakayamaJapan
| | - Shunsuke Kikuchi
- Department of Orthopedic SurgeryKeio University School of Medicine, ShinjukuTokyoJapan
| | - Masaharu Nishikino
- The National Institutes for Quantum and Radiological Science and Technology Quantum Beam Science Research Directorate Kansai Photon Science InstituteKyotoJapan
| | - Toshiyuki Kitamura
- The National Institutes for Quantum and Radiological Science and Technology Quantum Beam Science Research Directorate Kansai Photon Science InstituteKyotoJapan
| | - Noboru Hasegawa
- The National Institutes for Quantum and Radiological Science and Technology Quantum Beam Science Research Directorate Kansai Photon Science InstituteKyotoJapan
| | - Morio Matsumoto
- Department of Orthopedic SurgeryKeio University School of Medicine, ShinjukuTokyoJapan
| | - Masaya Nakamura
- Department of Orthopedic SurgeryKeio University School of Medicine, ShinjukuTokyoJapan
| | - Takeo Nagura
- Department of Orthopedic SurgeryKeio University School of Medicine, ShinjukuTokyoJapan,Department of Clinical BiomechanicsKeio University School of Medicine, ShinjukuTokyoJapan
| |
Collapse
|
7
|
Hosseinitabatabaei S, Kawalilak CE, McDonald MP, Kontulainen SA, Johnston JD. Distal radius sections offer accurate and precise estimates of forearm fracture load. Clin Biomech (Bristol, Avon) 2020; 80:105144. [PMID: 32829235 DOI: 10.1016/j.clinbiomech.2020.105144] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 06/08/2020] [Accepted: 08/10/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Forearm fracture risk can be estimated via factor-of-risk: the ratio of applied impact force to forearm fracture load. Simple techniques are available for estimating impact force associated with a fall; estimating forearm fracture load is more challenging. Our aim was to assess whether failure load estimates of sections of the distal radius (acquired using High-Resolution peripheral Quantitative Computed Tomography and finite element modeling) offer accurate and precise estimates of forearm fracture load. METHODS We scanned a section of the distal radius of 19 cadaveric forearms (female, mean age 83.7, SD 8.3), and 34 women (75.0, 7.7). Sections were converted to finite element models and failure loads were acquired for different failure criteria. We assessed forearm fracture load using experimental testing simulating a fall on the outstretched hand. We used linear regression to derive relationships between ex vivo forearm fracture load and finite element derived distal radius failure load. We used derived regression coefficients to estimate forearm fracture load, and assessed explained variance and prediction error. We used root-mean-squared coefficients of variation to assess in vivo precision errors of estimated forearm fracture load. FINDINGS Failure load estimates of sections of the distal radius, used in conjunction with derived regression coefficients, explained 89-90% of the variance in experimentally-measured forearm fracture load with prediction errors <6.8% and precision errors <5.0%. INTERPRETATION Failure load estimates of distal radius sections can reliably estimate forearm fracture load experienced during a fall. Forearm fracture load estimates can be used to improve factor-of-risk predictions for forearm fracture.
Collapse
Affiliation(s)
- Seyedmahdi Hosseinitabatabaei
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada
| | - Chantal E Kawalilak
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada
| | - Matthew P McDonald
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada
| | - Saija A Kontulainen
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada; College of Kinesiology, University of Saskatchewan, 87 Campus Drive, Saskatoon, SK S7N 5B2, Canada
| | - James D Johnston
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada; Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada.
| |
Collapse
|
8
|
Stuck AK, Schenk D, Zysset P, Bütikofer L, Mathis A, Lippuner K. Reference values and clinical predictors of bone strength for HR-pQCT-based distal radius and tibia strength assessments in women and men. Osteoporos Int 2020; 31:1913-1923. [PMID: 32451557 DOI: 10.1007/s00198-020-05405-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Accepted: 03/27/2020] [Indexed: 10/24/2022]
Abstract
UNLABELLED Reference values for radius and tibia strength using multiple-stack high-resolution peripheral quantitative computed tomography (HR-pQCT) with homogenized finite element analysis are presented in order to derive critical values improving risk prediction models of osteoporosis. Gender and femoral neck areal bone mineral density (aBMD) were independent predictors of bone strength. INTRODUCTION The purpose was to obtain reference values for radius and tibia bone strength computed by using the homogenized finite element analysis (hFE) using multiple stacks with a HR-pQCT. METHODS Male and female healthy participants aged 20-39 years were recruited at the University Hospital of Bern. They underwent interview and clinical examination including hand grip, gait speed and DXA of the hip. The nondominant forearm and tibia were scanned with a double and a triple-stack protocol, respectively, using HR-pQCT (XCT II, SCANCO Medical AG). Bone strength was estimated by using the hFE analysis, and reference values were calculated using quantile regression. Multivariable analyses were performed to identify clinical predictors of bone strength. RESULTS Overall, 46 women and 41 men were recruited with mean ages of 25.1 (sd 5.0) and 26.2 (sd 5.2) years. Sex-specific reference values for bone strength were established. Men had significantly higher strength for radius (mean (sd) 6640 (1800) N vs. 4110 (1200) N; p < 0.001) and tibia (18,200 (4220) N vs. 11,970 (3150) N; p < 0.001) than women. In the two multivariable regression models with and without total hip aBMD, the addition of neck hip aBMD significantly improved the model (p < 0.001). No clinical predictors of bone strength other than gender and aBMD were identified. CONCLUSION Reference values for radius and tibia strength using multiple HR-pQCT stacks with hFE analysis are presented and provide the basis to help refining accurate risk prediction models. Femoral neck aBMD and gender were significant predictors of bone strength.
Collapse
Affiliation(s)
- A K Stuck
- Department of Geriatrics, Inselspital, Bern University Hospital, and University of Bern, Bern, 3010, Switzerland
| | - D Schenk
- ARTORG Center for Biomedical Engineering Research, University of Bern, Freiburgstrasse 3, 3010, Bern, Switzerland
| | - P Zysset
- ARTORG Center for Biomedical Engineering Research, University of Bern, Freiburgstrasse 3, 3010, Bern, Switzerland
| | - L Bütikofer
- CTU Bern, University of Bern, 3010, Bern, Switzerland
| | - A Mathis
- ARTORG Center for Biomedical Engineering Research, University of Bern, Freiburgstrasse 3, 3010, Bern, Switzerland
| | - K Lippuner
- Department of Osteoporosis, Inselspital, Bern University Hospital, University of Bern, Bern, 3010, Switzerland.
| |
Collapse
|
9
|
Johnston JD, McDonald MP, Kontulainen SA. Off-axis loads cause failure of the distal radius at lower magnitudes than axial loads: A side-to-side experimental study. J Orthop Res 2020; 38:1688-1692. [PMID: 31989687 DOI: 10.1002/jor.24601] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Accepted: 01/21/2020] [Indexed: 02/04/2023]
Abstract
Off-axis loading associated with a fall onto the outstretched hand has been hypothesized to induce distal radius failure at lower magnitudes than axially directed loading commonly used in biomechanical models for estimating fracture risk. However, this hypothesis has not been tested with side-to-side experimental testing. The objective of this study was to compare distal radius failure loads between forearm pairs experimentally tested in an axial or off-axis loading configuration. We acquired 18 pairs of cadaveric forearms from 18 female donors (mean age (standard deviation): 84.4 (7.9) years). Each forearm pair was tested to failure using either an axial compression test (vertical orientation with 0° dorsal inclination, 3°-6° radial inclination) or an off-axis test corresponding to the hand position during a fall (15° dorsal inclination, 3°-6° radial inclination). Failure testing was performed at 3 mm/s onto the palm of the hand until fracture occurred. Of the 18 pairs, 11 sustained a distal radius fracture. We compared failure loads between the two groups using a paired t test. Results indicated that failure load under off-axis loading was 29% lower than failure load under axial compressive loading (mean difference: -0.31 kN; 95% confidence interval: -0.47 to -0.16 kN, P = .001). In conclusion, off-axis loading associated with a fall onto the outstretched hand resulted in a 29% lower failure load. Integrating an off-axis loading configuration into current biomechanical models of distal radius bone strength may prevent overestimating of failure load and may offer a clinically relevant option to estimate distal radius fracture risk and monitor therapy efficacy.
Collapse
Affiliation(s)
- James D Johnston
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Matthew P McDonald
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Saija A Kontulainen
- College of Kinesiology, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| |
Collapse
|
10
|
Akgül T, Korkmaz M, Pehlivanoglu T, Bayram S, Özdemir MA, Karalar Ş. Biomechanical Comparison of Pull-out Strength of Different Cementation and Pedicle Screw Placement Techniques in a Calf Spine Model. Indian J Orthop 2020; 54:134-140. [PMID: 32952921 PMCID: PMC7474045 DOI: 10.1007/s43465-020-00199-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 07/11/2020] [Indexed: 02/04/2023]
Abstract
BACKGROUND We hypothesized that an entire pedicle screw tract cement augmentation has greater strength than traditional techniques. METHOD Twenty-four fresh frozen calf lumbar spines were randomized into three study groups, each having eight vertebrae: (1) screw cemented after vertebroplasty; (2) fenestrated cemented screw; and (3) cementation of the entire pedicle screw tract. For the right side screws, two pedicle screws were inserted in each vertebra with the standard position in the sagittal plane, whereas the left side screws were placed at a 30° angle craniocaudal plane. From the recorded force-displacement curves, the maximum peak load (failure load) of each screw was determined. The mode of failure was screw stripping at all levels tested. RESULTS The pull-out strength for standard screw replacement at the sagittal plane was 1843.3 N, 1707.45 N, and 5365.1 N consecutively. The failure load value in the standard position in the sagittal plane in the cementation of the entire pedicle screw tract group was significantly higher than that in the fenestrated cemented screw group and screw cemented after vertebroplasty (p < 0.001 and p < 0.001, respectively). The standard pedicle screw position in the sagittal plane showed a significant pull-out strength than the others (p < 0.001). CONCLUSION The pull-out strength of the cementation of the entire pedicle screw tract was 2.5 times higher than the others. The pull-out strength of the pedicle screws in malposition obtained the same strength to the standard positions after the augmentation procedure in our study.
Collapse
Affiliation(s)
- Turgut Akgül
- Department of Orthopedics and Traumatology, Faculty of Medicine, Istanbul University, Çapa Fatih, Istanbul, 34093 Turkey
| | - Murat Korkmaz
- Department of Orthopedics and Traumatology, Faculty of Medicine, KOÇ University, Istanbul, Turkey
| | - Tuna Pehlivanoglu
- Department of Orthopedics and Traumatology, Emsey Hospital, Istanbul, Turkey
| | - Serkan Bayram
- Department of Orthopedics and Traumatology, Faculty of Medicine, Istanbul University, Çapa Fatih, Istanbul, 34093 Turkey
| | - Mustafa Abdullah Özdemir
- Department of Orthopedics and Traumatology, Faculty of Medicine, Istanbul University, Çapa Fatih, Istanbul, 34093 Turkey
| | - Şahin Karalar
- Department of Orthopedics and Traumatology, Faculty of Medicine, Istanbul University, Çapa Fatih, Istanbul, 34093 Turkey
| |
Collapse
|
11
|
Misir A, Ozturk K, Kizkapan TB, Yildiz KI, Gur V, Sevencan A. Fracture lines and comminution zones in OTA/AO type 23C3 distal radius fractures: The distal radius map. J Orthop Surg (Hong Kong) 2019; 26:2309499017754107. [PMID: 29366391 DOI: 10.1177/2309499017754107] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVE This study was designed to define fracture lines and comminution zones in OTA/AO 23C3 distal radius fractures from axial computed tomography (CT) images that would influence surgical planning, development of new classifications, and possible implant designs. METHODS Thirty-four consecutive OTA/AO 23C3 fractures treated by a single surgeon between January 2014 and December 2014 were analyzed. For each fracture, maps of the fracture lines and zones of comminution were drawn. Each map was digitized and graphically superimposed to create a compilation of fracture lines and zones of comminution. Based on this compilation, major and minor fracture lines were identified and fracture patterns were defined. RESULTS All major fracture lines were distributed in the central region of the radius distal articular surface. There is a recurrent fracture pattern with a comminution zone including the scaphoid and lunate fossa; Lister's tubercle; and ulnar, volar, and radial zones. CONCLUSION It is important for the practicing surgeon to understand these four main fragments. Knowledge of this constant pattern should influence the development of new classifications and possible implant designs.
Collapse
Affiliation(s)
- Abdulhamit Misir
- 1 Department of Orthopaedics and Traumatology, Sanliurfa Training and Research Hospital, Sanliurfa, Turkey
| | - Kahraman Ozturk
- 2 Department of Hand and Upper Extremity Surgery, Baltalimani Bone and Joint Diseases Training and Research Hospital, Istanbul, Turkey
| | - Turan Bilge Kizkapan
- 3 Department of Orthopaedics and Traumatology, Baltalimani Bone and Joint Diseases Training and Research Hospital, Istanbul, Turkey
| | - Kadir Ilker Yildiz
- 3 Department of Orthopaedics and Traumatology, Baltalimani Bone and Joint Diseases Training and Research Hospital, Istanbul, Turkey
| | - Volkan Gur
- 1 Department of Orthopaedics and Traumatology, Sanliurfa Training and Research Hospital, Sanliurfa, Turkey
| | - Ahmet Sevencan
- 1 Department of Orthopaedics and Traumatology, Sanliurfa Training and Research Hospital, Sanliurfa, Turkey
| |
Collapse
|
12
|
Zhou B, Zhang Z, Hu Y, Wang J, Yu YE, Nawathe S, Nishiyama KK, Keaveny TM, Shane E, Guo XE. Regional Variations of HR-pQCT Morphological and Biomechanical Measurements of the Distal Radius and Tibia and Their Associations with Whole Bone Mechanical Properties. J Biomech Eng 2019; 141:2737740. [PMID: 31260520 DOI: 10.1115/1.4044175] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Indexed: 11/08/2022]
Abstract
High-resolution peripheral quantitative computed tomography (HRpQCT) is a promising imaging modality that provides in vivo three-dimensional assessment of bone microstructure by scanning fixed regions of the distal radius and tibia. However, how microstructural parameters and mechanical analysis based on these segment scans correlate to whole distal radius and tibia mechanics is not well-characterized. On 26 sets of cadaveric radius and tibia, HRpQCT scans were performed on the standard scan segment, a segment distal to the standard segment, and a segment proximal to the standard segment. Whole distal bone stiffness was determined through mechanical testing. Segment bone stiffness was estimated using linear finite element (FE) analysis based on segment scans. Standard morphological and Individual Trabecula Segmentation (ITS) analyses were used estimate microstructural properties. Significant variations in microstructural parameters were observed among segments at both sites. Correlation to whole distal bone stiffness was moderate for microstructural parameters at the standard segment, but correlation was significantly increased for FE-predicted segment bone stiffness based on standard segment scans. Similar correlation strengths were found between FE-predicted segment bone stiffness and whole distal bone stiffness. Additionally, microstructural parameters at the distal segment had higher correlation to whole distal bone stiffness than at standard or proximal segments. Our results suggest that FE-predicted segment stiffness is a better predictor of whole distal bone stiffness for clinical HRpQCT analysis, and that microstructural parameters at the distal segment is more highly correlated with whole distal bone stiffness than at the standard or proximal segments.
Collapse
Affiliation(s)
- Bin Zhou
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, New York, U.S.A
| | - Zhendong Zhang
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, New York, U.S.A.; Department of Orthopedic Surgery, First Affiliated Hospital, School of Medicine, Shihezi University, Shihezi, Xinjiang, China
| | - Yizhong Hu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, New York, U.S.A
| | - Ji Wang
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, New York, U.S.A
| | - Y Eric Yu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, New York, U.S.A
| | - Shashank Nawathe
- Orthopaedic Biomechanics Laboratory, Department of Mechanical Engineering, University of California, Berkeley, California, U.S.A
| | - Kyle K Nishiyama
- Division of Endocrinology, Department of Medicine, Columbia University, New York, New York, U.S.A
| | - Tony M Keaveny
- Orthopaedic Biomechanics Laboratory, Department of Mechanical Engineering, University of California, Berkeley, California, U.S.A
| | - Elizabeth Shane
- Division of Endocrinology, Department of Medicine, Columbia University, New York, New York, U.S.A
| | - X Edward Guo
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, 351 Engineering Terrace, Mail Code 8904, 1210 Amsterdam Avenue, New York, NY 10027, U.S.A
| |
Collapse
|
13
|
Du J, Brooke-Wavell K, Paggiosi MA, Hartley C, Walsh JS, Silberschmidt VV, Li S. Characterising variability and regional correlations of microstructure and mechanical competence of human tibial trabecular bone: An in-vivo HR-pQCT study. Bone 2019; 121:139-148. [PMID: 30658093 DOI: 10.1016/j.bone.2019.01.013] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Revised: 01/11/2019] [Accepted: 01/14/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Quantifying spatial distribution of trabecular bone mechanical competence and microstructure is important for early diagnosis of skeletal disorders and potential risk of fracture. The objective of this study was to determine a spatial distribution of trabecular mechanical and morphological properties in human distal tibia and examine the contribution of regional variability of trabecular microarchitecture to mechanical competence. METHODS A total of 340 representative volume elements at five anatomic regions of trabecular bone - anterior, posterior, lateral, medial and centre - from ten white European-origin postmenopausal women were studied. Region-specific trabecular parameters such as trabecular volume fraction, trabecular thickness, trabecular number, trabecular surface area, trabecular separation, plate-like structure fraction and finite element analysis of trabecular stiffness were determined based on in-vivo high resolution peripheral quantitative computed tomographic (HR-pQCT) images of distal tibiae from ten postmenopausal women. Mean values were compared using analysis of variance. The correlations between morphological parameters and stiffness were calculated. RESULTS Significant regional variation in trabecular microarchitecture of the human distal tibia was observed (p < 0.05), with up to 106% differences between lowest (central and anterior) and highest (medial and posterior) regions. Higher proportion of plate-like trabecular morphology (63% and 53%) was found in medial and posterior regions in the distal tibia. Stiffness estimated from finite element models also differed significantly (p < 0.05), with stiffness being 4.5 times higher in the highest (medial) than lowest (central) regions. The bone volume fraction was the strongest correlate of stiffness in all regions. CONCLUSION A novel finding of this study is the fact that significant regional variation of stiffness derived from two-phased FEA model with individual trabecula representation correlated highly to regional morphology obtained from in-vivo HR-pQCT images at the distal tibia. The correlations between regional morphological parameters and mechanical competence of trabecular bone were consistent at all regions studied, with regional BV/TV showing the highest correlation. The method developed for regional analysis of trabecular mechanical competence may offer a better insight into the relationship between mechanical behaviour and microstructure of bone. The findings provide evidence needed to further justify a larger-cohort feasibility study for early detection of bone degenerative diseases: examining regional variations in mechanical competence and trabecular specifications may allow better understanding of fracture risks in addition to others contributing factors.
Collapse
Affiliation(s)
- Juan Du
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Leicestershire, UK
| | | | | | - Chris Hartley
- School of Sport, Exercise and Health Science, Loughborough University, Leicestershire, UK
| | - Jennifer S Walsh
- Mellanby Centre for Bone Research, University of Sheffield, Sheffield, UK
| | - Vadim V Silberschmidt
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Leicestershire, UK
| | - Simin Li
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Leicestershire, UK.
| |
Collapse
|
14
|
Nakashima D, Ishii K, Nishiwaki Y, Kawana H, Jinzaki M, Matsumoto M, Nakamura M, Nagura T. Quantitative CT-based bone strength parameters for the prediction of novel spinal implant stability using resonance frequency analysis: a cadaveric study involving experimental micro-CT and clinical multislice CT. Eur Radiol Exp 2019; 3:1. [PMID: 30671863 PMCID: PMC6342748 DOI: 10.1186/s41747-018-0080-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Accepted: 11/20/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND To predict conventional test forces (peak torque and pull-out force) and a new test force (implant stability quotient [ISQ] value of a spinal pedicle screw) from computed tomography (CT) parameters, including micro-architectural parameters, using high-resolution micro-CT and clinical multislice CT (MSCT) in human cadaveric vertebrae. METHODS Micro-CT scans before/after screw insertion (n = 68) and MSCT scans before screw insertion (n = 58) of human cadaveric vertebrae were assessed for conventional test forces and ISQ value. Three-dimensional volume position adjustment between pre-insertion micro-CT and MSCT scans and post-insertion scans (micro-CT) was performed to extract the volume of the cancellous bone surrounding the pedicle screw. The following volume bone mineral density and micro-architectural parameters were calculated: bone volume fraction, bone surface density (bone surface/total volume (BS/TV)), trabecular thickness, trabecular separation, trabecular number, structure model index, and number of nodes (branch points) of the cancellous bone network/total volume (NNd/TV) using Spearman's rank correlation coefficient with Bonferroni correction. RESULTS Conventional test forces showed the strongest correlation with BS/TV: peak torque, ρ = 0.811, p = 4.96 × 10-17(micro-CT) and ρ = 0.730, p = 7.87 × 10-11 (MSCT); pull-out force, ρ = 0.730, p = 1.64 × 10-12 (micro-CT) and ρ = 0.693, p = 1.64 × 10-9 (MSCT). ISQ value showed the strongest correlation with NNd/TV: ρ = 0.607, p = 4.01 × 10-8 (micro-CT) and ρ = 0.515, p = 3.52 × 10-5 (MSCT). CONCLUSIONS Test forces, including the ISQ value, can be predicted using micro-CT and MSCT parameters. This is useful for establishing a preoperative fixation strength evaluation system.
Collapse
Affiliation(s)
- Daisuke Nakashima
- Department of Orthopedic surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku, Tokyo, Japan
| | - Ken Ishii
- Department of Orthopedic surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku, Tokyo, Japan.,Department of Orthopedic surgery, International University of Health and Welfare School of Medicine, Narita, Chiba, Japan
| | - Yuji Nishiwaki
- Department of Environmental and Occupational Health, School of Medicine, Toho University, Tokyo, Japan
| | - Hiromasa Kawana
- Department of Dentistry and Oral Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Masahiro Jinzaki
- Department of Radiology, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Morio Matsumoto
- Department of Orthopedic surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku, Tokyo, Japan
| | - Masaya Nakamura
- Department of Orthopedic surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku, Tokyo, Japan
| | - Takeo Nagura
- Department of Orthopedic surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku, Tokyo, Japan. .,Department of Clinical Biomechanics, Keio University School of Medicine, Shinjuku, Tokyo, Japan.
| |
Collapse
|
15
|
Yadav S, Sachs E, Vishwanath M, Knecht K, Upadhyay M, Nanda R, Tadinada A. Gender and growth variation in palatal bone thickness and density for mini-implant placement. Prog Orthod 2018; 19:43. [PMID: 30393829 PMCID: PMC6215790 DOI: 10.1186/s40510-018-0241-1] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Accepted: 09/07/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The objective was to compare the palatal bone thickness (PBT) and palatal bone density (PBD) in the anterior, middle, and posterior part of the palate in males and females. METHODS This retrospective study reviewed cone beam computed tomography scans of 359 patients. The scans were divided into 99 growing males, 105 growing females, 74 non-growing males, and 81 non-growing females. The measurements of PBT and PBD were made in between the canine and first premolar, the first premolar and second premolar, the second premolar and first molar, and the first molar and second molar. The measurements were made in the center of the palate and 4 mm away from the center. ANOVA was used to analyze the PBT and PBD in different areas between four different groups. RESULTS The PBT was lower (P < 0.0001) as we moved from the anterior to the posterior palate. The PBT was more (P < 0.001) in the center of the palate than 4 mm away from the center, except in between the canine and first premolar. The growing male and non-growing male had higher (P < 0.0001) PBT than the growing female and non-growing female in between the canine and first premolar and the first premolar and second premolar both in the center and 4 mm away from it. The PBD was higher (P < 0.05) in between the canine and first premolar area at the center of the palate and between the second premolar and first molar 4 mm away from the center in all the experimental groups. CONCLUSIONS There exists a definite gender and growth variation in the PBT and PBD in different parts of the palate. Palatal bone thickness between the males and females revealed that the males had significantly higher PBT than the females.
Collapse
Affiliation(s)
- Sumit Yadav
- Division of Orthodontics, University of Connecticut Health Center, Farmington, USA. .,School of Dental Medicine, University of Connecticut Health Center, 263 Farmington Avenue, L7062A MC1725, Farmington, CT, 06030, USA.
| | - Emily Sachs
- School of Dental Medicine, University of Connecticut Health Center, 263 Farmington Avenue, L7062A MC1725, Farmington, CT, 06030, USA
| | - Meenakshi Vishwanath
- Division of Orthodontics, University of Nebraska Medical Center, Farmington, USA
| | | | - Madhur Upadhyay
- Division of Orthodontics, University of Connecticut Health Center, Farmington, USA
| | - Ravindra Nanda
- Division of Orthodontics, University of Connecticut Health Center, Farmington, USA
| | - Aditya Tadinada
- Division of Oral Health and Diagnostic Sciences, University of Connecticut Health Center, Farmington, USA
| |
Collapse
|
16
|
Shaw SC, Parsons CM, Fuggle NR, Edwards MH, Robinson SM, Dennison EM, Cooper C, Ward KA. Diet Quality and Bone Measurements Using HRpQCT and pQCT in Older Community-Dwelling Adults from the Hertfordshire Cohort Study. Calcif Tissue Int 2018; 103:494-500. [PMID: 29931462 PMCID: PMC6174074 DOI: 10.1007/s00223-018-0445-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Accepted: 06/14/2018] [Indexed: 01/10/2023]
Abstract
There are few data describing associations between dietary patterns and bone microarchitecture. This study investigated the relationship between diet quality and HRpQCT and pQCT measures in older adults. Data were available for 184 men and 166 women. Dietary data were collected at baseline (1998-2003) using an administered food frequency questionnaire. A 'prudent' diet score (PDS) was identified using principal component analysis and used as an indicator of dietary quality. HRpQCT and pQCT images were acquired at follow-up in 2012, from the non-dominant distal radius and tibia using Scanco XtremeCT and Stratec XCT2000 instrument scanners, respectively. The mean (SD) PDS was - 0.24 (1.23) for men and 0.62 (1.14) for women. In women, a significant positive relationship was found between baseline dietary pattern and total and trabecular area at both the radius and the tibia, measured by HRpQCT. Similar trends were observed with pQCT parameters. Positive associations were observed for tibia total area (38% slice). At the radius, significant positive associations were found for total area (4% slice) and polar strength strain index (33% slice). All relationships remained robust to adjustment. For men, although patterns were similar, there were no significant associations for HRpQCT outcomes. Significant associations were observed for baseline PDS and polar strength strain and total area (66% slice) at the radius, measured by pQCT. Our data suggest that diets high in fruit, vegetables, oily fish and whole grain cereals in early old age are associated with greater bone size but not volumetric bone density or microarchitecture in later life in women.
Collapse
Affiliation(s)
- S C Shaw
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton General Hospital, Southampton, SO16 6YD, UK
- Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS FT, Southampton, UK
| | - C M Parsons
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton General Hospital, Southampton, SO16 6YD, UK
| | - N R Fuggle
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton General Hospital, Southampton, SO16 6YD, UK
| | - M H Edwards
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton General Hospital, Southampton, SO16 6YD, UK
- Portsmouth Hospitals NHS Trust, Portsmouth, UK
| | - S M Robinson
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton General Hospital, Southampton, SO16 6YD, UK
- Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS FT, Southampton, UK
| | - E M Dennison
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton General Hospital, Southampton, SO16 6YD, UK
| | - C Cooper
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton General Hospital, Southampton, SO16 6YD, UK.
- Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS FT, Southampton, UK.
- National Institute for Health Research Musculoskeletal Biomedical Research Unit, University of Oxford, Oxford, OX3 7LE, UK.
| | - K A Ward
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton General Hospital, Southampton, SO16 6YD, UK
- MRC Elsie Widdowson Laboratory, Cambridge, UK
| |
Collapse
|
17
|
Nakashima D, Ishii K, Matsumoto M, Nakamura M, Nagura T. A study on the use of the Osstell apparatus to evaluate pedicle screw stability: An in-vitro study using micro-CT. PLoS One 2018; 13:e0199362. [PMID: 29953480 PMCID: PMC6023144 DOI: 10.1371/journal.pone.0199362] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Accepted: 06/06/2018] [Indexed: 11/18/2022] Open
Abstract
Pull-out force and insertion torque have not been generally used as intraoperative measures for the evaluation of pedicle screw stability because of their invasiveness. On the other hand, resonance frequency analysis is a non-invasive and repeatable technique that has been clinically used in dentistry to evaluate implant stability e.g. by the Osstell apparatus. In this study, the characteristics of the implant stability quotient (ISQ) value obtained by the Osstell apparatus in the field of spinal surgery were investigated. Biomechanical test materials simulating human bone were used to provide a comparative platform for evaluating each fixation strength measure, including pull-out force, insertion torque, and the ISQ value. To perform pull-out force measurement and to repeat pedicle screw insertion and removal, loosening was artificially created, and its effect was investigated. The grade of loosening was quantified on a micro-CT image after pedicle screw removal. In the comparison of the 3 fixation strength measures, the correlations of the ISQ value with the pull-out force (R2 = 0.339 p <0.0001) and the insertion torque (R2 = 0.337 p <0.0001) were lower than the correlation between pull-out force and insertion torque (R2 = 0.918 p <0.0001). On a micro-CT study, the material volume of the internal threads disappeared after destruction of its integrity due to repeated pedicle screw insertion and removal. Material integrity destruction of the internal threads decreased only the pull-out force and the insertion torque, but it did not affect the ISQ value. The ISQ value only decreased when the material volume of the internal threads disappeared, probably because the ISQ value reflects the resistance against a force in the perpendicular direction of the screw, unlike the conventional measures of fixation strength, such as pull-out force and insertion torque, which reflect axial load.
Collapse
Affiliation(s)
- Daisuke Nakashima
- Department of Orthopedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Ken Ishii
- Department of Orthopedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan.,Department of Orthopedic Surgery, International University of Health and Welfare School of Medicine, Narita, Chiba, Japan
| | - Morio Matsumoto
- Department of Orthopedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Masaya Nakamura
- Department of Orthopedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| | - Takeo Nagura
- Department of Orthopedic Surgery, Keio University School of Medicine, Shinjuku, Tokyo, Japan.,Department of Clinical Biomechanics, Keio University School of Medicine, Shinjuku, Tokyo, Japan
| |
Collapse
|
18
|
Bonaretti S, Majumdar S, Lang TF, Khosla S, Burghardt AJ. The comparability of HR-pQCT bone measurements is improved by scanning anatomically standardized regions. Osteoporos Int 2017; 28:2115-2128. [PMID: 28391447 PMCID: PMC5526099 DOI: 10.1007/s00198-017-4010-7] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2016] [Accepted: 03/13/2017] [Indexed: 12/16/2022]
Abstract
UNLABELLED We investigated the sensitivity of distal bone density, structure, and strength measurements by high-resolution peripheral quantitative computed tomography (HR-pQCT) to variability in limb length. Our results demonstrate that HR-pQCT should be performed at a standard %-of-total-limb-length to avoid substantial measurement bias in population study comparisons and the evaluation of individual skeletal status in a clinical context. INTRODUCTION High-resolution peripheral quantitative computed tomography (HR-pQCT) measures of bone do not account for anatomic variability in bone length: a 1-cm volume is acquired at a fixed offset from an anatomic landmark. Our goal was to evaluate HR-pQCT measurement variability introduced by imaging fixed vs. proportional volumes and to propose a standard protocol for relative anatomic positioning. METHODS Double-length (2-cm) scans were acquired in 30 adults. We compared measurements from 1-cm sub-volumes located at the default fixed offset, and the average %-of-length offset. The average position corresponded to 4.0% ± 1.1 mm for radius, and 7.2% ± 2.2 mm for tibia. We calculated the RMS difference in bone parameters and T-scores to determine the measurement variability related to differences in limb length. We used anthropometric ratios to estimate the mean limb length for published HR-pQCT reference data, and then calculated mean %-of-length offsets. RESULTS Variability between fixed vs. relative scan positions was highest in the radius, and for cortical bone in general (RMS difference Ct.Th = 19.5%), while individuals had T-score differentials as high as +3.0 SD (radius Ct.BMD). We estimated that average scan position for published HR-pQCT reference data corresponded to 4.0% at the radius, and 7.3% at tibia. CONCLUSION Variability in limb length introduces significant bias to HR-pQCT measures, confounding cross-sectional analyses and limiting the clinical application for individual assessment of skeletal status. We propose to standardize scan positioning using 4.0 and 7.3% of total bone length for the distal radius and tibia, respectively.
Collapse
Affiliation(s)
- S Bonaretti
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology & Biomedical Imaging, University of California, QB3 Building, Suite 203, 1700 4th St, San Francisco, CA, 94158, USA
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - S Majumdar
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology & Biomedical Imaging, University of California, QB3 Building, Suite 203, 1700 4th St, San Francisco, CA, 94158, USA
| | - T F Lang
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology & Biomedical Imaging, University of California, QB3 Building, Suite 203, 1700 4th St, San Francisco, CA, 94158, USA
| | - S Khosla
- Division of Endocrinology, Metabolism and Nutrition, Department of Internal Medicine, College of Medicine, Mayo Clinic, Rochester, MN, USA
| | - A J Burghardt
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology & Biomedical Imaging, University of California, QB3 Building, Suite 203, 1700 4th St, San Francisco, CA, 94158, USA.
| |
Collapse
|
19
|
Bonaretti S, Vilayphiou N, Chan CM, Yu A, Nishiyama K, Liu D, Boutroy S, Ghasem-Zadeh A, Boyd SK, Chapurlat R, McKay H, Shane E, Bouxsein ML, Black DM, Majumdar S, Orwoll ES, Lang TF, Khosla S, Burghardt AJ. Operator variability in scan positioning is a major component of HR-pQCT precision error and is reduced by standardized training. Osteoporos Int 2017; 28:245-257. [PMID: 27475931 PMCID: PMC5568957 DOI: 10.1007/s00198-016-3705-5] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2015] [Accepted: 07/07/2016] [Indexed: 02/02/2023]
Abstract
UNLABELLED In this study, we determined that operator positioning precision contributes significant measurement error in high-resolution peripheral quantitative computed tomography (HR-pQCT). Moreover, we developed software to quantify intra- and inter-operator variability and demonstrated that standard positioning training (now available as a web-based application) can significantly reduce inter-operator variability. INTRODUCTION HR-pQCT is increasingly used to assess bone quality, fracture risk, and anti-fracture interventions. The contribution of the operator has not been adequately accounted in measurement precision. Operators acquire a 2D projection ("scout view image") and define the region to be scanned by positioning a "reference line" on a standard anatomical landmark. In this study, we (i) evaluated the contribution of positioning variability to in vivo measurement precision, (ii) measured intra- and inter-operator positioning variability, and (iii) tested if custom training software led to superior reproducibility in new operators compared to experienced operators. METHODS To evaluate the operator in vivo measurement precision, we compared precision errors calculated in 64 co-registered and non-co-registered scan-rescan images. To quantify operator variability, we developed software that simulates the positioning process of the scanner's software. Eight experienced operators positioned reference lines on scout view images designed to test intra- and inter-operator reproducibility. Finally, we developed modules for training and evaluation of reference line positioning. We enrolled six new operators to participate in a common training, followed by the same reproducibility experiments performed by the experienced group. RESULTS In vivo precision errors were up to threefold greater (Tt.BMD and Ct.Th) when variability in scan positioning was included. The inter-operator precision errors were significantly greater than the short-term intra-operator precision (p < 0.001). New trained operators achieved comparable intra-operator reproducibility to experienced operators and lower inter-operator reproducibility (p < 0.001). Precision errors were significantly greater for the radius than for the tibia. CONCLUSION Operator reference line positioning contributes significantly to in vivo measurement precision and is significantly greater for multi-operator datasets. Inter-operator variability can be significantly reduced using a systematic training platform, now available online ( http://webapps.radiology.ucsf.edu/refline/ ).
Collapse
Affiliation(s)
- S Bonaretti
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA.
- Department of Radiology, Stanford University, Stanford, CA, USA.
| | | | - C M Chan
- University of California Berkeley, Berkeley, CA, USA
| | - A Yu
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - K Nishiyama
- Division of Endocrinology, Department of Medicine, Columbia University Medical Center, New York, NY, USA
| | - D Liu
- University of British Columbia, Vancouver, BC, Canada
| | - S Boutroy
- INSERM UMR 1033, Université de Lyon, Lyon, France
| | - A Ghasem-Zadeh
- Department of Medicine, Austin Health, University of Melbourne, Melbourne, Australia
| | - S K Boyd
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - R Chapurlat
- INSERM UMR 1033, Université de Lyon, Lyon, France
| | - H McKay
- University of British Columbia, Vancouver, BC, Canada
| | - E Shane
- Division of Endocrinology, Department of Medicine, Columbia University Medical Center, New York, NY, USA
| | - M L Bouxsein
- Center for Advanced Orthopaedic Studies, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - D M Black
- Department of Epidemiology and Biostatistics, University of California, San Francisco, CA, USA
| | - S Majumdar
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - E S Orwoll
- Division of Endocrinology, Bone and Mineral Unit, Oregon Health & Science University, Portland, OR, USA
| | - T F Lang
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - S Khosla
- Division of Endocrinology, Metabolism and Nutrition, Department of Internal Medicine, College of Medicine, Mayo Clinic, Rochester, MN, USA
| | - A J Burghardt
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| |
Collapse
|
20
|
Casagrande DJ, Morris RP, Carayannopoulos NL, Buford WL. Relationship Between Ulnar Variance, Cortical Bone Density, and Load to Failure in the Distal Radius at the Typical Site of Fracture Initiation. J Hand Surg Am 2016; 41:e461-e468. [PMID: 27707565 DOI: 10.1016/j.jhsa.2016.08.021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Revised: 08/24/2016] [Accepted: 08/28/2016] [Indexed: 02/02/2023]
Abstract
PURPOSE Increased ulnar variance has been shown to lead to diminished load borne by the distal radius. The purpose of this study was to determine the correlations among ulnar variance, bone mineral density, and load to failure at the distal radius. METHODS Posteroanterior radiographs and computed tomographic scans were taken of 12 cadaveric forearms in neutral rotation. Ulnar variance was measured for each wrist by the method of perpendiculars. Measurements of cortical, trabecular, and combined bone density were made at the distal radius. We performed linear regression analysis and correlation analysis to determine the relationship between bone densities and ulnar variance measurements. Next, we loaded the 12 cadaveric radii to failure under axial compression. Linear regression analysis and correlation analysis were then performed to determine the relationship between load to failure and both ulnar variance and cortical density. RESULTS Increased ulnar variance was significantly correlated with decreased cortical bone density at the distal radius and both were correlated with decreased load to failure. We found no correlation between ulnar variance and trabecular density or combined trabecular and cortical bone density at the distal radius. CONCLUSIONS Our study found that increased ulnar variance and decreased cortical bone mineral density correlates with decreased load to failure under axial compression. CLINICAL RELEVANCE Ulnar variance is linked to both bone quality and load to failure at the distal radius.
Collapse
Affiliation(s)
- Danielle J Casagrande
- Department of Orthopaedic Surgery and Rehabilitation, University of Texas Medical Branch, Galveston, TX.
| | - Randal P Morris
- Department of Orthopaedic Surgery and Rehabilitation, University of Texas Medical Branch, Galveston, TX
| | | | - William L Buford
- Department of Orthopaedic Surgery and Rehabilitation, University of Texas Medical Branch, Galveston, TX
| |
Collapse
|
21
|
Kawalilak CE, Kontulainen SA, Amini MA, Lanovaz JL, Olszynski WP, Johnston JD. In vivo precision of three HR-pQCT-derived finite element models of the distal radius and tibia in postmenopausal women. BMC Musculoskelet Disord 2016; 17:389. [PMID: 27619649 PMCID: PMC5020521 DOI: 10.1186/s12891-016-1238-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2015] [Accepted: 08/31/2016] [Indexed: 01/09/2023] Open
Abstract
Background The distal radius is the most common osteoporotic fracture site occurring in postmenopausal women. Finite element (FE) modeling is a non-invasive mathematical technique that can estimate bone strength using inputted geometry/micro-architecture and tissue material properties from computed tomographic images. Our first objective was to define and compare in vivo precision errors for three high-resolution peripheral quantitative computed tomography (HR-pQCT, XtremeCT; Scanco) based FE models of the distal radius and tibia in postmenopausal women. Our second objective was to assess the role of scan interval, scan quality, and common region on precision errors of outcomes for each FE model. Methods Models included: single-tissue model (STM), cortical-trabecular dual-tissue model (DTM), and one scaled model using imaged bone mineral density (E-BMD). Using HR-pQCT, we scanned the distal radius and tibia of 34 postmenopausal women (74 ± 7 years), at two time points. Primary outcomes included: tissue stiffness, apparent modulus, average von Mises stress, and failure load. Precision errors (root-mean-squared coefficient of variation, CV%RMS) were calculated. Multivariate ANOVA was used to compare the mean of individual CV% among the 3 HR-pQCT-based FE models. Spearman correlations were used to characterize the associations between precision errors of all FE model outcomes and scan/time interval, scan quality, and common region. Significance was accepted at P < 0.05. Results At the distal radius, CV%RMS precision errors were <9 % (Range STM: 2.8–5.3 %; DTM: 2.9–5.4 %; E-BMD: 4.4–8.7 %). At the distal tibia, CV%RMS precision errors were <6 % (Range STM: 2.7–4.8 %; DTM: 2.9–3.8 %; E-BMD: 1.8–2.5 %). At the radius, Spearman correlations indicated associations between the common region and associated precision errors of the E-BMD-derived apparent modulus (ρ = −0.392; P < 0.001) and von Mises stress (ρ = −0.297; P = 0.007). Conclusion Results suggest that the STM and DTM are more precise for modeling apparent modulus, average von Mises stress, and failure load at the distal radius. Precision errors were comparable for all three models at the distal tibia. Results indicate that the noted differences in precision error at the distal radius were associated with the common scan region, illustrating the importance of participant repositioning within the cast and reference line placement in the scout view during the scanning process.
Collapse
Affiliation(s)
- C E Kawalilak
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK, S7N 5A9, Canada.
| | - S A Kontulainen
- College of Kinesiology, University of Saskatchewan, Saskatoon, Canada
| | - M A Amini
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK, S7N 5A9, Canada
| | - J L Lanovaz
- College of Kinesiology, University of Saskatchewan, Saskatoon, Canada
| | - W P Olszynski
- College of Medicine, University of Saskatchewan, Saskatoon, Canada
| | - J D Johnston
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK, S7N 5A9, Canada
| |
Collapse
|
22
|
Wakasugi T, Shirasaka R. Intramedullary Nail Fixation for Displaced and Unstable Distal Radial Fractures in Patients Aged 65 Years or Older. J Hand Surg Asian Pac Vol 2016; 21:59-63. [PMID: 27454504 DOI: 10.1142/s2424835516500089] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND Distal radius fractures in elderly patients are now commonly treated with a volar locking plate, but flexor pollicis longus dysfunction caused by stripping of the muscle and tendon irritation and rupture caused by prominence of the implant have been reported. Intramedullary implants can stabilize distal radius fractures while minimally affecting the flexor and extensor tendons and muscles around the site, but osteoporosis in elderly patients might affect the radiographic and functional results of distal radius fractures treated by intramedullary implants. We investigated the radiographic and functional results of intramedullary implants for distal radius fractures in patients ≥65 years of age. METHODS We reviewed medical records of 40 patients with extra-articular or simple intra-articular fractures with the sagittal fracture line treated by an intramedullary implant. RESULTS All fractures achieved bony union, with an average radial inclination of 24.9 degrees, volar tilt of 9.2 degrees, and ulnar variance of 0.7 mm. We encountered one case of postoperative volar displacement of the distal fragment due to the small size of the intramedullary implant. The average range of motion was 69.8 and 59.9 degrees for dorsal and palmar wrist flexion, respectively. Average percentile grip strength of the uninjured side was 97%. The average Mayo modified wrist score at final follow-up was 91.9 points, with 20 patients graded as excellent, 16 as good, and 4 as fair. CONCLUSIONS The findings of this study indicate that intramedullary implants for dorsally displaced extra-articular or simple intraarticular distal radius fractures may offer good radiological and functional outcomes without hardware irritation in elderly patients. Distal radius fractures with an osteoporotic, large medullary canal should be stabilized by implants of an appropriate size.
Collapse
Affiliation(s)
- Takuma Wakasugi
- 1 Department of Orthopaedic Surgery, Tsuchiura Kyodo Hospital, Ibaraki, Japan
| | - Ritsuro Shirasaka
- 1 Department of Orthopaedic Surgery, Tsuchiura Kyodo Hospital, Ibaraki, Japan
| |
Collapse
|
23
|
Boutroy S, Khosla S, Sornay-Rendu E, Zanchetta MB, McMahon DJ, Zhang CA, Chapurlat RD, Zanchetta J, Stein EM, Bogado C, Majumdar S, Burghardt AJ, Shane E. Microarchitecture and Peripheral BMD are Impaired in Postmenopausal White Women With Fracture Independently of Total Hip T-Score: An International Multicenter Study. J Bone Miner Res 2016; 31:1158-66. [PMID: 26818785 PMCID: PMC4891284 DOI: 10.1002/jbmr.2796] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2015] [Revised: 12/23/2015] [Accepted: 12/29/2015] [Indexed: 11/06/2022]
Abstract
Because single-center studies have reported conflicting associations between microarchitecture and fracture prevalence, we included high-resolution peripheral quantitative computed tomography (HR-pQCT) data from five centers worldwide into a large multicenter analysis of postmenopausal women with and without fracture. Volumetric BMD (vBMD) and microarchitecture were assessed at the distal radius and tibia in 1379 white postmenopausal women (age 67 ± 8 years); 470 (34%) had at least one fracture including 349 with a major fragility fracture. Age, height, weight, and total hip T-score differed across centers and were employed as covariates in analyses. Women with fracture had higher BMI, were older, and had lower total hip T-score, but lumbar spine T-score was similar between groups. At the radius, total and trabecular vBMD and cortical thickness were significantly lower in fractured women in three out of five centers, and trabecular number in two centers. Similar results were found at the tibia. When data from five centers were combined, however, women with fracture had significantly lower total, trabecular, and cortical vBMD (2% to 7%), lower trabecular number (4% to 5%), and thinner cortices (5% to 6%) than women without fracture after adjustment for covariates. Results were similar at the radius and tibia. Similar results were observed with analysis restricted to major fragility fracture, vertebral and hip fractures, and peripheral fracture (at the radius). When focusing on osteopenic women, each SD decrease of total and trabecular vBMD was associated with a significantly increased risk of major fragility fracture (OR = 1.55 to 1.88, p < 0.01) after adjustment for covariates. Moreover, trabecular architecture modestly improved fracture discrimination beyond peripheral total vBMD. In conclusion, we observed differences by center in the magnitude of fracture/nonfracture differences at both the distal radius and tibia. However, when data were pooled across centers and the sample size increased, we observed significant and consistent deficits in vBMD and microarchitecture independent of total hip T-score in all postmenopausal white women with fracture and in the subgroup of osteopenic women, compared to women who never had a fracture. © 2016 American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Stephanie Boutroy
- College of Physicians and Surgeons, Columbia University Medical Center, New York, NY, USA.,INSERM UMR1033, Université de Lyon, Hospices Civils de Lyon, Lyon, France
| | - Sundeep Khosla
- Endocrine Research Unit, College of Medicine, Mayo Clinic, Rochester, MN, USA
| | | | - Maria Belen Zanchetta
- Instituto de Diagnóstico e Investigaciones Metabolicas (IDIM), Universidad del Salvador, Buenos Aires, Argentina
| | - Donald J McMahon
- College of Physicians and Surgeons, Columbia University Medical Center, New York, NY, USA
| | - Chiyuan A Zhang
- College of Physicians and Surgeons, Columbia University Medical Center, New York, NY, USA
| | - Roland D Chapurlat
- INSERM UMR1033, Université de Lyon, Hospices Civils de Lyon, Lyon, France
| | - Jose Zanchetta
- Instituto de Diagnóstico e Investigaciones Metabolicas (IDIM), Universidad del Salvador, Buenos Aires, Argentina
| | - Emily M Stein
- College of Physicians and Surgeons, Columbia University Medical Center, New York, NY, USA
| | - Cesar Bogado
- Instituto de Diagnóstico e Investigaciones Metabolicas (IDIM), Universidad del Salvador, Buenos Aires, Argentina
| | - Sharmila Majumdar
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Andrew J Burghardt
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Elizabeth Shane
- College of Physicians and Surgeons, Columbia University Medical Center, New York, NY, USA
| |
Collapse
|
24
|
Kawalilak CE, Johnston JD, Cooper DML, Olszynski WP, Kontulainen SA. Role of endocortical contouring methods on precision of HR-pQCT-derived cortical micro-architecture in postmenopausal women and young adults. Osteoporos Int 2016; 27:789-96. [PMID: 26252976 DOI: 10.1007/s00198-015-3262-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2015] [Accepted: 07/24/2015] [Indexed: 10/23/2022]
Abstract
UNLABELLED Precision errors of cortical bone micro-architecture from high-resolution peripheral quantitative computed tomography (pQCT) ranged from 1 to 16 % and did not differ between automatic or manually modified endocortical contour methods in postmenopausal women or young adults. In postmenopausal women, manually modified contours led to generally higher cortical bone properties when compared to the automated method. INTRODUCTION First, the objective of the study was to define in vivo precision errors (coefficient of variation root mean square (CV%RMS)) and least significant change (LSC) for cortical bone micro-architecture using two endocortical contouring methods: automatic (AUTO) and manually modified (MOD) in two groups (postmenopausal women and young adults) from high-resolution pQCT (HR-pQCT) scans. Second, it was to compare precision errors and bone outcomes obtained with both methods within and between groups. METHODS Using HR-pQCT, we scanned twice the distal radius and tibia of 34 postmenopausal women (mean age ± SD 74 ± 7 years) and 30 young adults (27 ± 9 years). Cortical micro-architecture was determined using AUTO and MOD contour methods. CV%RMS and LSC were calculated. Repeated measures and multivariate ANOVA were used to compare mean CV% and bone outcomes between the methods within and between the groups. Significance was accepted at P < 0.05. RESULTS CV%RMS ranged from 0.9 to 16.3 %. Within-group precision did not differ between evaluation methods. Compared to young adults, postmenopausal women had better precision for radial cortical porosity (precision difference 9.3 %) and pore volume (7.5 %) with MOD. Young adults had better precision for cortical thickness (0.8 %, MOD) and tibial cortical density (0.2 %, AUTO). In postmenopausal women, MOD resulted in 0.2-54 % higher values for most cortical outcomes, as well as 6-8 % lower radial and tibial cortical BMD and 2 % lower tibial cortical thickness. CONCLUSIONS Results suggest that AUTO and MOD endocortical contour methods provide comparable repeatability. In postmenopausal women, manual modification of endocortical contours led to generally higher cortical bone properties when compared to the automated method, while no between-method differences were observed in young adults.
Collapse
Affiliation(s)
- C E Kawalilak
- College of Kinesiology, University of Saskatchewan, 87 Campus Drive, Saskatoon, SK, S7N 5B2, Canada.
| | - J D Johnston
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK, S7N 5A9, Canada.
| | - D M L Cooper
- Department of Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, 107 Wiggins Road, Saskatoon, SK, S7N 5E5, Canada.
| | - W P Olszynski
- Director of the Saskatoon CaMos Centre; College of Medicine, University of Saskatchewan, 39 23rd St E Suite 103, Saskatoon, SK, S7K 0H6, Canada.
| | - S A Kontulainen
- College of Kinesiology, University of Saskatchewan, 87 Campus Drive, Saskatoon, SK, S7N 5B2, Canada.
| |
Collapse
|
25
|
Femoral condyle insufficiency fractures: associated clinical and morphological findings and impact on outcome. Skeletal Radiol 2015; 44:1785-94. [PMID: 26290325 DOI: 10.1007/s00256-015-2234-1] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Revised: 08/01/2015] [Accepted: 08/03/2015] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To determine the characteristics of femoral condyle insufficiency fracture (FCIF) lesions and their relative associations with the risk of clinical progression. MATERIALS AND METHODS This HIPAA-compliant retrospective study was approved by our Institutional Review Board. Seventy-three patients (age range, 19-95) were included after excluding patients with post-traumatic fractures, bone marrow infarct, osteochondritis dissecans, or underlying tumor. Two board-certified musculoskeletal radiologists classified morphologic findings including lesion diameter, associated bone marrow edema pattern, and associated cartilage/meniscus damage. Electronic medical charts were evaluated for symptoms, risk factors, and longitudinal outcomes, including total knee arthroplasty (TKA). Imaging characteristics were correlated with clinical findings, and comparison of outcome groups was performed using a regression model adjusted for age. RESULTS The majority of patients with FCIF were women (64.4%, 47/73), on average 10 years older than men (66.28 ± 15.86 years vs. 56.54 ± 10.39 years, p = 0.005). The most common location for FCIF was the central weight-bearing surface of the medial femoral condyle; overlying full thickness cartilage loss (75.7%, 53/70) and ipsilateral meniscal injury (94.1%, 64/68) were frequently associated. Clinical outcomes were variable, with 23.9% (11/46) requiring TKA. Cartilage WORMS score, adjacent cartilage loss, and contralateral meniscal injury, in addition to decreased knee range of motion at presentation, were significantly associated with progression to TKA (p < 0.05). CONCLUSIONS FCIF are frequently associated with overlying cartilage loss and ipsilateral meniscal injury. The extent of cartilage loss and meniscal damage, in addition to loss of knee range of motion at the time of presentation, are significantly associated with clinical progression.
Collapse
|
26
|
Obert L, Loisel F, Gasse N, Lepage D. Distal radius anatomy applied to the treatment of wrist fractures by plate: a review of recent literature. SICOT J 2015; 1:14. [PMID: 27163070 PMCID: PMC4849245 DOI: 10.1051/sicotj/2015012] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Few studies on the anatomy of the radial epiphysis have been published in the past 10 years. However, with the availability of new intra- and extra-medullary implants and the recent rash of avoidable iatrogenic injuries, now is the time for a more detailed description of the metaphyseal-epiphyseal regions in the distal radius. Published studies on distal radius anatomy in recent years have focused on three aspects: distal limit and watershed line, dorsal tubercle, and wrist columns. Furthermore, a fresh look at distal radius biomechanics shows that the loads experienced by the distal radius vary greatly. This information should be taken into account during volar plating of distal radius fractures.
Collapse
Affiliation(s)
- Laurent Obert
- Orthopaedic, Traumatology, Plastic & Hand Surgery Unit, University Hospital of Besançon 25000 Besançon France ; Intervention, Innovation, Imagery, Engineering in Health (EA 4268), Medical and Pharmacology Section, IFR 133, University of Franche-Comté 25000 Besançon France
| | - François Loisel
- Orthopaedic, Traumatology, Plastic & Hand Surgery Unit, University Hospital of Besançon 25000 Besançon France
| | - Nicolas Gasse
- Clinique Saint Vincent 40 chemin des Tilleroyes 25044 Besançon Cedex France
| | - Daniel Lepage
- Orthopaedic, Traumatology, Plastic & Hand Surgery Unit, University Hospital of Besançon 25000 Besançon France ; Intervention, Innovation, Imagery, Engineering in Health (EA 4268), Medical and Pharmacology Section, IFR 133, University of Franche-Comté 25000 Besançon France
| |
Collapse
|
27
|
Nirody JA, Cheng KP, Parrish RM, Burghardt AJ, Majumdar S, Link TM, Kazakia GJ. Spatial distribution of intracortical porosity varies across age and sex. Bone 2015; 75:88-95. [PMID: 25701139 PMCID: PMC4454740 DOI: 10.1016/j.bone.2015.02.006] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2014] [Revised: 01/15/2015] [Accepted: 02/06/2015] [Indexed: 11/25/2022]
Abstract
Cortical bone porosity is a major determinant of strength, stiffness, and fracture toughness of cortical tissue. The goal of this work was to investigate changes in spatial distribution and microstructure of cortical porosity associated with aging in men and women. The specific aims were to: 1) develop an automated technique for spatial analysis of cortical microstructure based on HR-pQCT data, and; 2) apply this technique to explore sex- and age-specific spatial distribution and microstructure of porosity within the cortex. We evaluated HR-pQCT images of the distal tibia from a cross-sectional cohort of 145 individuals, characterizing detectable pores as being in the endosteal, midcortical, or periosteal layers of the cortex. Metrics describing porosity, pore number, and pore size were quantified within each layer and compared across sexes, age groups, and cortical layers. The elderly cohort (65-78 years, n=22) displayed higher values than the young cohort (20-29 years, n=29) for all parameters both globally and within each layer. While all three layers displayed significant age-related porosity increases, the greatest difference in porosity between the young and elderly cohort was in the midcortical layer (+344%, p<0.001). Similarly, the midcortical layer reflected the greatest differences between young and elderly cohorts in both pore number (+243%, p<0.001) and size (+28%, p<0.001). Females displayed greater age-related changes in porosity and pore number than males. Females and males displayed comparable small to non-significant changes with age in pore size. In summary, considerable variability exists in the spatial distribution of detectable cortical porosity at the distal tibia, and this variability is dependent on age and sex. Intracortical pore distribution analysis may ultimately provide insight into both mechanisms of pore network expansion and biomechanical consequences of pore distribution.
Collapse
Affiliation(s)
- Jasmine A Nirody
- Biophysics Graduate Group, University of California, Berkeley, CA, USA.
| | - Karen P Cheng
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA; Department of Bioengineering, University of California, Berkeley, CA.
| | - Robin M Parrish
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA.
| | - Andrew J Burghardt
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA.
| | - Sharmila Majumdar
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA.
| | - Thomas M Link
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA.
| | - Galateia J Kazakia
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA.
| |
Collapse
|
28
|
Lutz M, Steck R, Sitte I, Rieger M, Schuetz M, Klestil T. The metaphyseal bone defect in distal radius fractures and its implication on trabecular remodeling-a histomorphometric study (case series). J Orthop Surg Res 2015; 10:61. [PMID: 25956925 PMCID: PMC4429963 DOI: 10.1186/s13018-015-0205-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2014] [Accepted: 03/29/2015] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The invention of the locking plate technology leads to alterations of treatment strategies at metaphyseal fracture sites with the concept of spontaneous remodeling of trabecular bone voids. Whereas trabecular regeneration has been proven in experimental animal studies, no histologic data exist on human fracture healing with special emphasis on bone voids. METHODS In order to qualify the trabecular bone remodeling capacity in vivo, bone specimens from the metaphyseal bone void were analyzed 14 months after trauma using quantitative histomorphometry. Twenty-five patients with an unstable dorsally displaced distal radius fracture were fixed with a palmar locking plate without additional bone graft or substitute. At implant removal, specimens from the previous compression void were harvested with a trephine in a volar-dorsal direction. In 16 patients, histomorphometric analysis could be performed, comparing the dorsal trabecular network with the volar, non-compressed ultrastructure. RESULTS Significant differences for bone volume/total volume (BV/TV), trabecular number (TbN) and trabecular separation (TbSp), but not for trabecular thickness (TbTh) and osteoid volume/total volume (OV/TV), were detected. Neither patient age, defect size nor gender had a significant influence on bone remodeling. CONCLUSIONS The results of this study indicate that trabecular bone remodeling does not lead to pre-trauma bone quality in metaphyseal bone compression voids following reduction and application of a locking plate.
Collapse
Affiliation(s)
- Martin Lutz
- Department for Trauma Surgery, LK Baden Mödling, Sr. M. Restituta Gasse 12, 2340, Mödling, Austria.
| | - Roland Steck
- Institute of Health and Biomedical Innovation, Queensland University of Technology Brisbane, 60 Musk Avenue, Kelvin Grove QLD, 4059, Brisbane, Australia.
| | - Ingrid Sitte
- Department for Trauma Surgery, Medical University Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
| | - Michael Rieger
- Department for Radiology General Hospital Hall in Tirol, Milser Strasse 10, 6060, Hall in Tirol, Austria.
| | - Michael Schuetz
- Institute of Health and Biomedical Innovation, Queensland University of Technology Brisbane, 60 Musk Avenue, Kelvin Grove QLD, 4059, Brisbane, Australia.
| | - Thomas Klestil
- Department for Trauma Surgery, LK Baden Mödling, Sr. M. Restituta Gasse 12, 2340, Mödling, Austria.
| |
Collapse
|
29
|
Ferrucci L, Baroni M, Ranchelli A, Lauretani F, Maggio M, Mecocci P, Ruggiero C. Interaction between bone and muscle in older persons with mobility limitations. Curr Pharm Des 2015; 20:3178-97. [PMID: 24050165 DOI: 10.2174/13816128113196660690] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2013] [Accepted: 09/13/2013] [Indexed: 12/18/2022]
Abstract
Aging is associated with a progressive loss of bone-muscle mass and strength. When the decline in mass and strength reaches critical thresholds associated with adverse health outcomes, they are operationally considered geriatric conditions and named, respectively, osteoporosis and sarcopenia. Osteoporosis and sarcopenia share many of the same risk factors and both directly or indirectly cause higher risk of mobility limitations, falls, fractures and disability in activities of daily living. This is not surprising since bones adapt their morphology and strength to the long-term loads exerted by muscle during anti-gravitational and physical activities. Non-mechanical systemic and local factors also modulate the mechanostat effect of muscle on bone by affecting the bidirectional osteocyte-muscle crosstalk, but the specific pathways that regulate these homeostatic mechanisms are not fully understood. More research is required to reach a consensus on cut points in bone and muscle parameters that identify individuals at high risk for adverse health outcomes, including falls, fractures and disability. A better understanding of the muscle-bone physiological interaction may help to develop preventive strategies that reduce the burden of musculoskeletal diseases, the consequent disability in older persons and to limit the financial burden associated with such conditions. In this review, we summarize age-related bone-muscle changes focusing on the biomechanical and homeostatic mechanisms that explain bone-muscle interaction and we speculate about possible pathological events that occur when these mechanisms become impaired. We also report some recent definitions of osteoporosis and sarcopenia that have emerged in the literature and their implications in clinical practice. Finally, we outline the current evidence for the efficacy of available anti-osteoporotic and proposed antisarcopenic interventions in older persons.
Collapse
Affiliation(s)
| | | | | | | | | | | | - C Ruggiero
- Institute of Gerontology and Geriatrics, Department of Medicine, University of Perugia, S. Andrea delle Fratte, 06100, Perugia, Italy.
| |
Collapse
|
30
|
Kawalilak CE, Johnston JD, Olszynski WP, Kontulainen SA. Characterizing microarchitectural changes at the distal radius and tibia in postmenopausal women using HR-pQCT. Osteoporos Int 2014; 25:2057-66. [PMID: 24781379 DOI: 10.1007/s00198-014-2719-0] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2013] [Accepted: 04/11/2014] [Indexed: 10/25/2022]
Abstract
UNLABELLED Limited prospective evidence exists regarding bone microarchitectural deterioration. We report annual changes in trabecular and cortical bone microarchitecture at the distal radius and tibia in postmenopausal women. Lost trabeculae with corresponding increase in trabecular thickness at the radius and thinning tibial cortex indicated trabecularization of the cortex at both sites. INTRODUCTION Osteoporosis is characterized by low bone mass and the deterioration of bone microarchitecture. However, limited prospective evidence exists regarding bone microarchitectural changes in postmenopausal women: a population prone to sustaining osteoporotic fractures. Our primary objective was to characterize the annual change in bone area, density, and microarchitecture at the distal radius and distal tibia in postmenopausal women. METHODS Distal radius and tibia were measured using high-resolution peripheral quantitative computed tomography (HR-pQCT) at baseline and 1 year later in 51 women (mean age ± SD, 77 ± 7 years) randomly sampled from the Saskatoon cohort of the Canadian Multicentre Osteoporosis Study (CaMos). We used repeated measures analysis of variance (ANOVA) with Bonferroni adjustment for multiple comparisons to characterize the mean annual change in total density, cortical perimeter, trabecular and cortical bone area, density, content, and microarchitecture. Significant changes were accepted at P < 0.05. RESULTS At the distal radius in women without bone-altering drugs, total density (-1.7%) and trabecular number (-6.4%) decreased, while trabecular thickness (+6.0%), separation (+8.6%), and heterogeneity (+12.1%) increased. At their distal tibia, cortical area (-4.5%), density (-1.9%), content (-6.3%), and thickness (-4.4%) decreased, while trabecular area (+0.4%) increased. CONCLUSIONS The observed loss of trabeculae with concomitant increase in trabecular size at the distal radius and the declined cortical thickness, density, and content at the distal tibia indicated a site-specific trabecularization of the cortical bone in postmenopausal women.
Collapse
Affiliation(s)
- C E Kawalilak
- College of Kinesiology, University of Saskatchewan, 87 Campus Drive, Saskatoon, SK, S7N 5B2, Canada,
| | | | | | | |
Collapse
|
31
|
Lavado-Garcia JM, Moran JM, Roncero-Martin R, Calderon-Garcia JF, Pedrera-Canal M, Rodriguez-Dominguez T, Fernandez-Fernandez P, Pedrera-Zamorano JD. Quantitative ultrasound measurements of the calcaneus and hand phalanges in elderly Spanish men: relationship with peripheral bone mineral density of the hand phalanges. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2014; 33:1279-1285. [PMID: 24958415 DOI: 10.7863/ultra.33.7.1279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
OBJECTIVES The aims of this pilot study were to describe quantitative ultrasound (US) measurements and peripheral bone mineral density (BMD) of the hand phalanges on dual-energy x-ray absorptiometry and to examine the correlations between them in elderly Spanish men. METHODS We studied 199 healthy men (mean age ± SD, 73.31 ± 5.10 years). The participants were not taking any medications, and they reported no diseases, including diseases that are associated with abnormalities in mineral metabolism. Phalangeal and calcaneal quantitative US measurements and phalangeal BMD measurements were performed in all participants. RESULTS A bivariate correlation analysis showed no association between quantitative US assessments at the phalanges or the calcaneus (P = .409). After adjustment for potential confounders, the correlation between phalangeal BMD and phalangeal quantitative US measurements was r = 0.417 (P < .0001), and the correlation for calcaneal quantitative US was r = 0.26 (P = .001). Further adjustment by percentage of body fat increased quantitative US correlations with phalangeal BMD: r = 0.450 (P < .0001) at the phalanges; r = 0.291 (P = .001) at the calcaneus. CONCLUSIONS There is a small correlation between quantitative US measurements at the calcaneus and phalangeal BMD that increases to a moderate level with quantitative US measurements at the phalanges in elderly Spanish men.
Collapse
Affiliation(s)
| | - Jose M Moran
- Metabolic Bone Diseases Research Group, University of Extremadura, Cáceres, Spain
| | - Raul Roncero-Martin
- Metabolic Bone Diseases Research Group, University of Extremadura, Cáceres, Spain
| | | | - Maria Pedrera-Canal
- Metabolic Bone Diseases Research Group, University of Extremadura, Cáceres, Spain
| | | | | | | |
Collapse
|
32
|
Ellouz R, Chapurlat R, van Rietbergen B, Christen P, Pialat JB, Boutroy S. Challenges in longitudinal measurements with HR-pQCT: evaluation of a 3D registration method to improve bone microarchitecture and strength measurement reproducibility. Bone 2014; 63:147-57. [PMID: 24614646 DOI: 10.1016/j.bone.2014.03.001] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2013] [Revised: 02/10/2014] [Accepted: 03/02/2014] [Indexed: 02/04/2023]
Abstract
Definition of identical regions between repeated computed tomography (CT) scans is a key factor to monitor changes in bone microarchitecture. In longitudinal studies, accurate determination of the volume of interest (VOI), using three dimensional (3D) registration may improve precision. Therefore, the aim of our study was to investigate the short-term reproducibility of bone geometry, density, microstructure and biomechanical parameters assessed by HR-pQCT and micro-finite element (μFE) derived analyses, using the cross-sectional area (CSA) registration method in comparison with the use of 3D registration, to find overlapping regions between scans. Fifteen healthy individuals (aged 21-47 years) underwent 3 separate scans at the distal radius and tibia, within a one-month interval. Reproducibility was assessed after double contouring the cortical compartment and after applying three different methods to determine the common region between repeated scans: (i) the VOI was determined with no registration, i.e., on 110 slices, (ii) the VOI was determined after CSA-based registration, and (iii) the VOI was determined after 3D registration. Both pre- and post-registration short-term reproducibility for each subject was determined. With no registration, CVrms of geometry parameters ranged from 0.5 to 3.7%, showing a slight variation in the CSA between scans. When the CSA registration method was employed, the variability of geometry (CVrms<1.8%) and density parameters (CVrms<1.8%), was better than that obtained without registration. By removing the effect of repositioning, the 3D registration further improved the reproducibility of cortical bone measurements compared to other methods. Indeed, significant improvements were found for cortical geometry and microstructure measurements (CVrms ranged from 0.4% to 10.7% at both sites; p<0.05), whereas the impact on trabecular bone measurements was restricted to its geometry parameter. The repositioning error was significantly reduced, most markedly at the radius compared to the tibia. For μFE measures, the impact of 3D registration on whole bone stiffness was negligible, indicating adequate assessment of longitudinal changes in estimated biomechanical properties, even without registration. In conclusion, we have shown that the 3D registration improved the identification of the common region retained for longitudinal analysis, contributing to improve the reproducibility of cortical bone parameter measurements. We also quantified the minimally detectable bone changes to help designing future studies with HR-pQCT.
Collapse
Affiliation(s)
| | | | - Bert van Rietbergen
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, The Netherlands.
| | - Patrik Christen
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, The Netherlands.
| | | | | |
Collapse
|
33
|
Hazrati Marangalou J, Ito K, Taddei F, van Rietbergen B. Inter-individual variability of bone density and morphology distribution in the proximal femur and T12 vertebra. Bone 2014; 60:213-20. [PMID: 24370733 DOI: 10.1016/j.bone.2013.12.019] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2013] [Revised: 12/16/2013] [Accepted: 12/17/2013] [Indexed: 01/16/2023]
Abstract
Bone geometry, density and microstructure can vary widely between subjects. Knowledge about this variation in a population is of interest in particular for the design of orthopedic implants and interventions. The goal of this study is to investigate the local variability of bone density and microstructural parameters between subjects using a novel inter-subject image registration approach. Human proximal femora of 29 and T12 vertebrae of 20 individuals were scanned using a HR-pQCT and a micro-CT system, respectively. A pre-defined iso-anatomic mesh template was morphed to each micro-CT scan. For each element bone volume fraction and other morphological parameters (Tb.Th, Tb.N, Tb.Sp, SMI, DA) were determined and assigned to the element. A coefficient of variation (CV) was calculated for each parameter at each element location of the 29 femora and 20 T12 vertebrae. Contour plots of the CV distribution revealed very detailed information about the inter-individual variation in bone density and morphology. It is also shown that analyzing large sub-volumes, as commonly done in previous studies, would miss much of this variation. Detailed quantitative information of bone morphological parameters for each sample in the femur and the T12 database and their inter-individual variability are available from the mesh templates as supplementary data (http://w3.bmt.tue.nl/nl/fe_database/). We expect that these results can help to optimize implants and orthopedic procedures by taking local bone morphological parameter variations into account.
Collapse
Affiliation(s)
- Javad Hazrati Marangalou
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Keita Ito
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Fulvia Taddei
- Laboratorio di Tecnologia Medica, Istituti Ortopedici Rizzoli, Bologna, Italy
| | - Bert van Rietbergen
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| |
Collapse
|
34
|
Ab-Lazid R, Perilli E, Ryan MK, Costi JJ, Reynolds KJ. Does cancellous screw insertion torque depend on bone mineral density and/or microarchitecture? J Biomech 2013; 47:347-53. [PMID: 24360200 DOI: 10.1016/j.jbiomech.2013.11.030] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2013] [Revised: 11/08/2013] [Accepted: 11/18/2013] [Indexed: 11/30/2022]
Abstract
During insertion of a cancellous bone screw, the torque level reaches a plateau, at the engagement of all the screw threads prior to the screw head contact. This plateau torque (T(Plateau)) was found to be a good predictor of the insertion failure torque (stripping) and also exhibited strong positive correlations with areal bone mineral density (aBMD) in ovine bone. However, correlations between T(Plateau) and aBMD, as well as correlations between T(Plateau) and bone microarchitecture, have never been explored in human bone. The aim of this study was to determine whether T(Plateau), a predictor of insertion failure torque, depends on aBMD and/or bone microarchitecture in human femoral heads. Fifty-two excised human femoral heads were obtained. The aBMD and microarchitecture of each specimen were evaluated using dual X-ray Absorptiometry and micro-computed tomography. A cancellous screw was inserted into specimens using an automated micro-mechanical test device, and T(Plateau) was calculated from the insertion profile. T(Plateau) exhibited the strongest correlation with the structure model index (SMI, R=-0.82, p<0.001), followed by bone volume fraction (BV/TV, R=0.80, p<0.01) and aBMD (R=0.76, p<0.01). Stepwise forward regression analysis showed an increase for the prediction of T(Plateau) when aBMD was combined with microarchitectural parameters, i.e., aBMD combined with SMI (R(2) increased from 0.58 to 0.72) and aBMD combined with BV/TV and BS/TV (R(2) increased from 0.58 to 0.74). In conclusion, T(Plateau), a strong predictor for insertion failure torque, is significantly dependent on bone microarchitecture (particularly SMI and BV/TV) and aBMD.
Collapse
Affiliation(s)
- Rosidah Ab-Lazid
- Medical Device Research Institute, School of Computer Science, Engineering and Mathematics, Flinders University, GP.O. Box 2100, Adelaide, South Australia 5001, Australia.
| | - Egon Perilli
- Medical Device Research Institute, School of Computer Science, Engineering and Mathematics, Flinders University, GP.O. Box 2100, Adelaide, South Australia 5001, Australia
| | - Melissa K Ryan
- Medical Device Research Institute, School of Computer Science, Engineering and Mathematics, Flinders University, GP.O. Box 2100, Adelaide, South Australia 5001, Australia
| | - John J Costi
- Medical Device Research Institute, School of Computer Science, Engineering and Mathematics, Flinders University, GP.O. Box 2100, Adelaide, South Australia 5001, Australia
| | - Karen J Reynolds
- Medical Device Research Institute, School of Computer Science, Engineering and Mathematics, Flinders University, GP.O. Box 2100, Adelaide, South Australia 5001, Australia
| |
Collapse
|
35
|
Vale AC, Aleixo IP, Lúcio M, Saraiva A, Caetano-Lopes J, Rodrigues A, Amaral PM, Rosa LG, Monteiro J, Fonseca JE, Vaz MF, Canhão H. At the moment of occurrence of a fragility hip fracture, men have higher mechanical properties values in comparison with women. BMC Musculoskelet Disord 2013; 14:295. [PMID: 24131745 PMCID: PMC4015558 DOI: 10.1186/1471-2474-14-295] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2012] [Accepted: 10/01/2013] [Indexed: 02/04/2023] Open
Abstract
Background It is well established that males have lower fracture risk in comparison with females, which suggests a higher bone resistance in men. The aim of our study was to find out if in older patients with hip fragility fractures, gender has also an impact on trabecular bone material behaviour, specifically to determine whether trabecular mechanical properties under compressive loading differ between men and women who suffered a fragility hip fracture. Methods Femoral epiphyses were consecutively collected during hip replacement surgery due to proximal femur fragility fracture. Trabecular bone cylinders were drilled and submitted to uniaxial compression tests and mechanical properties were assessed. Results Seventy-three patients, 55 women (mean age 81 years and standard deviation of 7 years) and 18 men (mean age 81 years and standard deviation of 8 years) were evaluated. The ultimate stress of trabecular bone was significantly higher in men than in women: the median values and the interquartile range (IQR) were respectively 8.04(5.35-10.90) MPa vs. 4.46(3.02-7.73) MPa, (p-value = 0.005). The same difference between male and female was observed in the Young’s modulus: 293.68(166.67-538.18) MPa vs. 174.26(73.07-322.28) MPa, (p-value = 0.028), and also in the energy to failure: 0.25(0.07-0.42) MJ/m3 vs. 0.11(0.05-0.25) MJ/m3, (p-value = 0.058). These differences were also verified after adjusting the analysis for age in a multivariate model analysis. Conclusions Our observations demonstrated that, even in a population who suffered a fragility hip fracture, men still have higher trabecular bone mechanical properties in comparison with women.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | - João E Fonseca
- Rheumatology Research Unit, Instituto de Medicina Molecular, Faculdade de Medicina da Universidade de Lisboa, Lisbon, Portugal.
| | | | | |
Collapse
|
36
|
Cylinders or walls? A new computational model to estimate the MR transverse relaxation rate dependence on trabecular bone architecture. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2013; 27:349-61. [PMID: 24061609 DOI: 10.1007/s10334-013-0402-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2012] [Revised: 08/22/2013] [Accepted: 08/22/2013] [Indexed: 10/26/2022]
Abstract
OBJECTIVE Bone density is distributed in a complex network of interconnecting trabecular plates and rods that are interspersed with bone marrow. A computational model to assess the dependence of the relaxation rate on the geometry of bone can consider the distribution of bone material in the form of two components: cylinders and open walls (walls with gaps). We investigate whether the experimentally known dependence of the transverse relaxation rate on the trabecular bone structure can be usefully interpreted in terms of these two components. MATERIALS AND METHODS We established a computer model based on an elementary computational cell. The model includes a variable number of open walls and infinitely long cylinders as well as multiple geometric parameters. The transverse relaxation rate is computed as a function of these parameters. Within the model, increasing the trabecular spacing with a fixed trabecular radius is equivalent to thinning the trabeculae while maintaining constant spacing. RESULTS Increasing the number of cylinder and wall gap elements beyond their nearest neighbors does not change the transverse relaxation rate. Although the absolute contribution to the relaxation due to open walls is on average more important than that due to cylinders, the latter drops off rapidly. The change on transverse relaxation rate is larger for changing cylinder geometry than for changing wall geometry, as it can be seen from the effect on the relaxation rate when trabecular spacing is varied, compared to varying the size of wall gaps. CONCLUSION Our results provide strong evidence that trabecular thinning, which is associated with increasing age, decreases the relaxation rates. The effect of thinning plates and rods on the transverse relaxation can be understood in terms of simple cylinders and open walls. A reduction in the relaxation rate can be seen as an indication of thinning cylinders, corresponding to reduced bone stability and ultimately, osteoporosis.
Collapse
|
37
|
Ou LC, Sun ZJ, Chang YF, Chang CS, Chao TH, Kuo PH, Lin RM, Wu CH. Epidemiological survey of quantitative ultrasound in risk assessment of falls in middle-aged and elderly people. PLoS One 2013; 8:e71053. [PMID: 23951077 PMCID: PMC3737261 DOI: 10.1371/journal.pone.0071053] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2013] [Accepted: 06/26/2013] [Indexed: 11/18/2022] Open
Abstract
UNLABELLED The risk assessment of falls is important, but still unsatisfactory and time-consuming. Our objective was to assess quantitative ultrasound (QUS) in the risk assessment of falls. Our study was designed as epidemiological cross-sectional study occurring from March 2009 to February 2010 by community survey at a medical center. The participants were collected from systemic sample of 1,200 community-dwelling people (Male/Female = 524/676) 40 years old and over in Yunlin County, Mid-Taiwan. Structural questionnaires including socioeconomic status, living status, smoking and drinking habits, exercise and medical history were completed. Quantitative ultrasound (QUS) at the non-dominant distal radial area (QUS-R) and the left calcaneal area (QUS-C) were measured. The overall prevalence of falls was 19.8%. In men, the independently associated factors for falls were age (OR: 1.04; 95%CI: 1.01~1.06), fracture history (OR: 1.89; 95%CI: 1.12~3.19), osteoarthritis history (OR: 3.66; 95%CI: 1.15~11.64) and speed of sound (OR: 0.99; 95%CI: 0.99~1.00; p<0.05) by QUS-R. In women, the independently associated factors for falls were current drinking (OR: 3.54; 95%CI: 1.35∼9.31) and broadband ultrasound attenuation (OR: 0.98; 95%CI: 0.97~0.99; p<0.01) by QUS-C. The cutoffs at -2.5< T-score<-1 derived using QUS-R (OR: 2.85; 95%CI: 1.64~4.96; p<0.01) in men or T-score ≦-2.5 derived using QUS-C (OR: 2.72; 95%CI: 1.42~5.21; p<0.01) in women showed an independent association with falls. The lowest T-score derived using either QUS-R or QUS-C was also revealed as an independent factor for falls in both men (OR: 2.13; 95%CI: 1.03~4.43; p<0.05) and women (OR: 2.36; 95%CI: 1.13~4.91; p<0.05). CONCLUSIONS Quantitative ultrasounds, measured either at the radial or calcaneal area, are convenient tools by which to assess the risk of falls in middle-aged and elderly people.
Collapse
Affiliation(s)
- Ling-Chun Ou
- Department of Internal Medicine, National Cheng Kung University Hospital Dou-Liou Branch, Yunlin, Taiwan
| | - Zih-Jie Sun
- Department of Internal Medicine, National Cheng Kung University Hospital Dou-Liou Branch, Yunlin, Taiwan
- Institute of Gerontology, National Cheng Kung University Medical College, Tainan, Taiwan
| | - Yin-Fan Chang
- Department of Family Medicine, National Cheng Kung University Hospital, Tainan, Taiwan
| | - Chin-Sung Chang
- Department of Family Medicine, National Cheng Kung University Hospital, Tainan, Taiwan
| | - Ting-Hsing Chao
- Department of Internal Medicine, National Cheng Kung University Hospital Dou-Liou Branch, Yunlin, Taiwan
| | - Po-Hsiu Kuo
- Department of Public Health and Institute of Epidemiology and Preventive Medicine, College of Public Health, National Taiwan University, Taipei, Taiwan
| | - Ruey-Mo Lin
- Department of Orthopadics, National Cheng Kung University Hospital Dou-Liou Branch, Yunlin, Taiwan
| | - Chih-Hsing Wu
- Department of Family Medicine, National Cheng Kung University Hospital, Tainan, Taiwan
- Institute of Gerontology, National Cheng Kung University Medical College, Tainan, Taiwan
- Institute of Behavior Medicine, National Cheng Kung University Medical College, Tainan, Taiwan
| |
Collapse
|
38
|
Affiliation(s)
- M. Gföhler
- Faculty of Mechanical and Industrial Engineering; University of Technology; Vienna; Austria
| | - C. Peham
- Companion Animals and Horses; University of Veterinary Medicine; Vienna; Austria
| |
Collapse
|
39
|
Vanderoost J, Søe K, Merrild DMH, Delaissé JM, van Lenthe GH. Glucocorticoid-induced changes in the geometry of osteoclast resorption cavities affect trabecular bone stiffness. Calcif Tissue Int 2013. [PMID: 23187898 DOI: 10.1007/s00223-012-9674-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Bone fracture risk can increase through bone microstructural changes observed in bone pathologies, such as glucocorticoid-induced osteoporosis. Resorption cavities present one of these microstructural aspects. We recently found that glucocorticoids (GCs) affect the shape of the resorption cavities. Specifically, we found that in the presence of GC osteoclasts (OCs) cultured on bone slices make more trenchlike cavities, compared to rather round cavities in the absence of GCs, while the total eroded surface remained constant. For this study, we hypothesized that trenchlike cavities affect bone strength differently compared to round cavities. To test this hypothesis, we cultured OCs on bone slices in the presence and absence of GC and quantified their dimensions. These data were used to model the effects of OC resorption cavities on bone mechanical properties using a validated beam-shell finite element model of trabecular bone. We demonstrated that a change in the geometry of resorption cavities is sufficient to affect bone competence. After correcting for the increased EV/BV with GCs, the difference to the control condition was no longer significant, indicating that the GC-induced increase in EV/BV, which is closely related to the shape of the cavities, highly determines the stiffness effect. The lumbar spine was the anatomic site most affected by the GC-induced changes on the shape of the cavities. These findings might explain the clinical observation that the prevalence of vertebral fractures during GC treatment increases more than hip, forearm and other nonvertebral fractures.
Collapse
Affiliation(s)
- Jef Vanderoost
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300c b2419, 3001, Leuven, Belgium
| | | | | | | | | |
Collapse
|
40
|
Burghardt AJ, Pialat JB, Kazakia GJ, Boutroy S, Engelke K, Patsch JM, Valentinitsch A, Liu D, Szabo E, Bogado CE, Zanchetta MB, McKay HA, Shane E, Boyd SK, Bouxsein ML, Chapurlat R, Khosla S, Majumdar S. Multicenter precision of cortical and trabecular bone quality measures assessed by high-resolution peripheral quantitative computed tomography. J Bone Miner Res 2013; 28:524-36. [PMID: 23074145 PMCID: PMC3577969 DOI: 10.1002/jbmr.1795] [Citation(s) in RCA: 95] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/04/2012] [Revised: 09/28/2012] [Accepted: 10/03/2012] [Indexed: 01/20/2023]
Abstract
High-resolution peripheral quantitative computed tomography (HR-pQCT) has recently been introduced as a clinical research tool for in vivo assessment of bone quality. The utility of this technology to address important skeletal health questions requires translation to standardized multicenter data pools. Our goal was to evaluate the feasibility of pooling data in multicenter HR-pQCT imaging trials. Reproducibility imaging experiments were performed using structure and composition-realistic phantoms constructed from cadaveric radii. Single-center precision was determined by repeat scanning over short-term (<72 hours), intermediate-term (3-5 months), and long-term intervals (28 months). Multicenter precision was determined by imaging the phantoms at nine different HR-pQCT centers. Least significant change (LSC) and root mean squared coefficient of variation (RMSCV) for each interval and across centers was calculated for bone density, geometry, microstructure, and biomechanical parameters. Single-center short-term RMSCVs were <1% for all parameters except cortical thickness (Ct.Th) (1.1%), spatial variability in cortical thickness (Ct.Th.SD) (2.6%), standard deviation of trabecular separation (Tb.Sp.SD) (1.8%), and porosity measures (6% to 8%). Intermediate-term RMSCVs were generally not statistically different from short-term values. Long-term variability was significantly greater for all density measures (0.7% to 2.0%; p < 0.05 versus short-term) and several structure measures: cortical thickness (Ct.Th) (3.4%; p < 0.01 versus short-term), cortical porosity (Ct.Po) (15.4%; p < 0.01 versus short-term), and trabecular thickness (Tb.Th) (2.2%; p < 0.01 versus short-term). Multicenter RMSCVs were also significantly higher than short-term values: 2% to 4% for density and micro-finite element analysis (µFE) measures (p < 0.0001), 2.6% to 5.3% for morphometric measures (p < 0.001), whereas Ct.Po was 16.2% (p < 0.001). In the absence of subject motion, multicenter precision errors for HR-pQCT parameters were generally less than 5%. Phantom-based multicenter precision was comparable to previously reported in in vivo single-center precision errors, although this was approximately two to five times worse than ex vivo short-term precision. The data generated from this study will contribute to the future design and validation of standardized procedures that are broadly translatable to multicenter study designs.
Collapse
Affiliation(s)
- Andrew J Burghardt
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Subject-specific bone loading estimation in the human distal radius. J Biomech 2013; 46:759-66. [DOI: 10.1016/j.jbiomech.2012.11.016] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2012] [Revised: 11/08/2012] [Accepted: 11/09/2012] [Indexed: 11/17/2022]
|
42
|
Kazakia GJ, Nirody JA, Bernstein G, Sode M, Burghardt AJ, Majumdar S. Age- and gender-related differences in cortical geometry and microstructure: Improved sensitivity by regional analysis. Bone 2013; 52:623-31. [PMID: 23142360 PMCID: PMC3564644 DOI: 10.1016/j.bone.2012.10.031] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2011] [Revised: 08/29/2012] [Accepted: 10/31/2012] [Indexed: 01/07/2023]
Abstract
OBJECTIVE While the importance of cortical structure quantification is increasingly underscored by recent literature, conventional analysis techniques obscure potentially important regional variations in cortical structure. The objective of this study was to characterize the spatial variability in cortical geometry and microstructure at the distal radius and tibia using high resolution peripheral quantitative computed tomography (HR-pQCT). We show that spatially-resolved analysis is able to identify cortical sub-regions with increased sensitivity to the effects of gender and aging. METHODS HR-pQCT scans of 146 volunteers (92 female/54 male) spanning a wide range of ages (20-78years) were analyzed. For each subject, radius and tibia scans were obtained using a clinical HR-pQCT system. Measures describing geometry (cortical bone thickness (Ct.Th)), microstructure (porosity (Ct.Po), pore diameter (Ct.Po.Dm), and pore size heterogeneity (Ct.Po.Dm SD)), and cortical bone density were calculated from the image data. Biomechanical parameters describing load and stress distribution were calculated using linear finite element analysis. Cortical quadrants were defined based on anatomic axes to quantify regional parameter variation. Subjects were categorized by gender, and age, and menopausal status for analysis. RESULTS Significant regional variation was found in all geometric and microstructural parameters in both the radius and tibia. In general, the radius showed more pronounced and significant variations in all parameters as compared with the tibia. At both sites, Ct.Po displayed the greatest regional variations. Correlation coefficients for Ct.Po and Ct.Th with respect to load and stress distribution provided evidence of an association between regional cortical structure and biomechanics in the tibia. Comparing women to men, differences in Ct.Po were most pronounced in the anterior quadrant of the radius (36% lower in women (p<0.01)) and the posterior quadrant of the tibia (27% lower in women (p<0.01)). Comparing elderly to young women, differences in Ct.Po were most pronounced in the lateral quadrant of the radius (328% higher in elderly women (p<0.001)) and the anterior quadrant of the tibia (433% higher in elderly women (p<0.001)). Comparing elderly to young men, the most pronounced age differences were found in the anterior radius (205% higher in elderly men, (p<0.001)) and the anterior tibia (190% higher in elderly men (p<0.01)). All subregional Ct.Po differences provided greater sensitivity to gender and age effects than those based on the global means. CONCLUSION These results show significant regional variation in all geometric and microarchitectural parameters studied in both the radius and tibia. Quantification of region-specific parameters provided increased sensitivity in the analysis of age- and gender-related differences, in many cases providing statistically significant differentiation of groups where conventional global analysis failed to detect differences. These results suggest that regional analysis may be important in studies of disease and therapeutic effects, particularly where microstructural parameters based on global analyses have thus far failed to identify a response in bone quality.
Collapse
Affiliation(s)
- Galateia J Kazakia
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA.
| | | | | | | | | | | |
Collapse
|
43
|
Characterisation of Trabecular Bone Structure. STUDIES IN MECHANOBIOLOGY, TISSUE ENGINEERING AND BIOMATERIALS 2013. [DOI: 10.1007/8415_2011_113] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
44
|
Abstract
The diagnosis and management of osteoporosis have been improved by the development of new quantitative methods of skeletal assessment and by the availability of an increasing number of therapeutic options, respectively. A number of imaging methods exist and all have advantages and disadvantages. Dual-energy X-ray absorptiometry (DXA) is the most widely available and commonly utilized method for clinical diagnosis of osteoporosis and will remain so for the foreseeable future. The WHO 10-year fracture risk assessment tool (FRAX(®)) will improve clinical use of DXA and the cost-effectiveness of therapeutic intervention. Improved reporting of radiographic features that suggest osteoporosis and the presence of vertebral fracture, which are powerful predictors of future fractures, could increase the frequency of appropriate DXA referrals. Quantitative CT remains predominantly a research tool, but has advantages over DXA--allowing measurement of volumetric density, separate measures of cortical and trabecular bone density, and evaluation of bone shape and size. High resolution imaging, using both CT and MRI, has been introduced to measure trabecular and cortical bone microstructure. Although these methods provide detailed insights into the effects of disease and therapies on bone, they are technically challenging and not widely available, so they are unlikely to be used in clinical practice.
Collapse
Affiliation(s)
- Judith E Adams
- Manchester Academic Health Science Centre, The Royal Infirmary and University of Manchester, Department of Radiology, The Royal Infirmary, Manchester M13 9WL, UK.
| |
Collapse
|
45
|
Popp AW, Windolf M, Senn C, Tami A, Richards RG, Brianza S, Schiuma D. Prediction of bone strength at the distal tibia by HR-pQCT and DXA. Bone 2012; 50:296-300. [PMID: 22088678 DOI: 10.1016/j.bone.2011.10.033] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2011] [Revised: 10/13/2011] [Accepted: 10/29/2011] [Indexed: 10/15/2022]
Abstract
BACKGROUND Areal bone mineral density (aBMD) at the distal tibia, measured at the epiphysis (T-EPI) and diaphysis (T-DIA), is predictive for fracture risk. Structural bone parameters evaluated at the distal tibia by high resolution peripheral quantitative computed tomography (HR-pQCT) displayed differences between healthy and fracture patients. With its simple geometry, T-DIA may allow investigating the correlation between bone structural parameter and bone strength. METHODS Anatomical tibiae were examined ex vivo by DXA (aBMD) and HR-pQCT (volumetric BMD (vBMD) and bone microstructural parameters). Cortical thickness (CTh) and polar moment of inertia (pMOI) were derived from DXA measurements. Finally, an index combining material (BMD) and mechanical property (polar moment of inertia, pMOI) was defined and analyzed for correlation with torque at failure and stiffness values obtained by biomechanical testing. RESULTS Areal BMD predicted the vBMD at T-EPI and T-DIA. A high correlation was found between aBMD and microstructural parameters at T-EPIas well as between aBMD and CTh at T-DIA. Finally, at T-DIA both indexes combining BMD and pMOI were strongly and comparably correlated with torque at failure and bone stiffness. CONCLUSION Ex vivo, at the distal tibial diaphysis, a novel index combining BMD and pMOI, which can be calculated directly from a single DXA measurement, predicted bone strength and stiffness better than either parameter alone and with an order of magnitude comparable to that of HR-pQCT. Whether this index is suitable for better prediction of fracture risk in vivo deserves further investigation.
Collapse
|
46
|
Abstract
The age-related reduction in bone mass is disproportionally related to skeletal weakening, suggesting that microarchitectural changes are also important determinants of bone quality. The study of cortical and trabecular microstructure, which for many years was mainly based on two-dimensional histologic and scanning electron microscopy imaging, gained a tremendous momentum in the last decade and a half, due to the introduction of microcomputed tomography (μCT). This technology provides highly accurate qualitative and quantitative analyses based on three-dimensional images at micrometer resolution, which combined with finite elemental analysis predicts the biomechanical implications of microstructural changes. Global μCT analyses of trabecular bone have repeatedly suggested that the main age-related change in this compartment is a decrease in trabecular number with unaltered, or even increased, trabecular thickness. However, we show here that this may result from a bias whereby thick trabeculae near the cortex and the early clearance of thin struts mask authentic trabecular thinning. The main cortical age-related change is increased porosity due to negatively balanced osteonal remodeling and expansion of Haversian canals, which occasionally merge with endosteal and periosteal resorption bays, thus leading to rapid cortical thinning and cortical weakening. The recent emergence of CT systems with submicrometer resolution provides novel information on the age-related decrease in osteocyte lacunar density and related micropetrosis, the result of lacunar hypermineralization. Last but not least, the use of the submicrometer CT systems confirmed the occurrence of microcracks in the skeletal mineralized matrix and vastly advanced their morphologic characterization and mode of initiation and propagation.
Collapse
Affiliation(s)
- Yankel Gabet
- Department of Anatomy and Anthropology, Sackler School of Medicine, Tel Aviv University, Tel Aviv, 69978, Israel
| | | |
Collapse
|
47
|
Melton LJ, Riggs BL, Müller R, Achenbach SJ, Christen D, Atkinson EJ, Amin S, Khosla S. Determinants of forearm strength in postmenopausal women. Osteoporos Int 2011; 22:3047-54. [PMID: 21308363 PMCID: PMC3150635 DOI: 10.1007/s00198-011-1540-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2010] [Accepted: 12/20/2010] [Indexed: 12/31/2022]
Abstract
UNLABELLED Bone strength at the ultradistal radius, quantified by micro-finite element modeling, can be predicted by variables obtained from high-resolution peripheral quantitative computed tomography scans. The specific formula for this bone strength surrogate (-555.2 + 8.1 × [trabecular vBMD] + 19.6 × [cortical area] + 4.2 × [total cross-sectional area]) should be validated and tested in fracture risk assessment. INTRODUCTION The purpose of this study was to identify key determinants of ultradistal radius (UDR) strength and evaluate their relationships with age, sex steroid levels, and measures of habitual skeletal loading. METHODS UDR failure load (~strength) was assessed by micro-finite element (μFE) modeling in 105 postmenopausal controls from an earlier forearm fracture case-control study. Predictors of bone strength obtained by high-resolution peripheral quantitative computed tomography (HRpQCT) in this group were then evaluated in a population-based cohort of 214 postmenopausal women. Sex steroids were measured by mass spectrometry. RESULTS A surrogate variable (-555.2 + 8.1 × [trabecular vBMD] + 19.6 × [cortical area] + 4.2 × [total cross-sectional area]) predicted UDR strength modeled by μFE (R(2) = 0.81), and all parameters except total cross-sectional area declined with age. Evaluated cross-sectionally, the 21% fall in predicted bone strength between ages 40-49 years and 80+ years more resembled the change in trabecular volumetric bone mineral density (vBMD) (-15%) than that in cortical area (-41%). In multivariable analyses, measures of body composition and physical activity were stronger predictors of UDR trabecular vBMD, cortical area, total cross-sectional area, and predicted bone strength than were sex steroid levels, but bio-available estradiol and testosterone were correlated with body mass. CONCLUSIONS Bone strength at the UDR, as quantified by μFE, can be predicted from variables obtained by HRpQCT. Predicted bone strength declines with age with changes in UDR trabecular vBMD and cortical area, related in turn to reduced skeletal loading and sex steroid levels. The predicted bone strength formula should be validated and tested in fracture risk assessment.
Collapse
Affiliation(s)
- L J Melton
- Division of Epidemiology, Department of Health Sciences Research, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA.
| | | | | | | | | | | | | | | |
Collapse
|
48
|
Edwards WB, Troy KL. Simulating Distal Radius Fracture Strength Using Biomechanical Tests: A Modeling Study Examining the Influence of Boundary Conditions. J Biomech Eng 2011; 133:114501. [DOI: 10.1115/1.4005428] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Distal radius fracture strength has been quantified using in vitro biomechanical testing. These tests are frequently performed using one of two methods: (1) load is applied directly to the embedded isolated radius or (2) load is applied through the hand with the wrist joint intact. Fracture loads established using the isolated radius method are consistently 1.5 to 3 times greater than those for the intact wrist method. To address this discrepancy, a validated finite element modeling procedure was used to predict distal radius fracture strength for 22 female forearms under boundary conditions simulating the isolated radius and intact wrist method. Predicted fracture strength was highly correlated between methods (r = 0.94; p < 0.001); however, intact wrist simulations were characterized by significantly reduced cortical shell load carriage and increased stress and strain concentrations. These changes resulted in fracture strength values less than half those predicted for the isolated radius simulations (2274 ± 824 N for isolated radius, 1124 ± 375 N for intact wrist; p < 0.001). The isolated radius method underestimated the mechanical importance of the trabecular compartment compared to the more physiologically relevant intact wrist scenario. These differences should be borne in mind when interpreting the physiologic importance of mechanical testing and simulation results.
Collapse
Affiliation(s)
- W. Brent Edwards
- Department of Kinesiology and Nutrition, University of Illinois at Chicago, Chicago, IL 60612
| | - Karen L. Troy
- Department of Kinesiology and Nutrition and Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60612
| |
Collapse
|
49
|
Burghardt AJ, Link TM, Majumdar S. High-resolution computed tomography for clinical imaging of bone microarchitecture. Clin Orthop Relat Res 2011; 469:2179-93. [PMID: 21344275 PMCID: PMC3126972 DOI: 10.1007/s11999-010-1766-x] [Citation(s) in RCA: 174] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The role of bone structure, one component of bone quality, has emerged as a contributor to bone strength. The application of high-resolution imaging in evaluating bone structure has evolved from an in vitro technology for small specimens to an emerging clinical research tool for in vivo studies in humans. However, many technical and practical challenges remain to translate these techniques into established clinical outcomes. QUESTIONS/PURPOSES We reviewed use of high-resolution CT for evaluating trabecular microarchitecture and cortical ultrastructure of bone specimens ex vivo, extension of these techniques to in vivo human imaging studies, and recent studies involving application of high-resolution CT to characterize bone structure in the context of skeletal disease. METHODS We performed the literature review using PubMed and Google Scholar. Keywords included CT, MDCT, micro-CT, high-resolution peripheral CT, bone microarchitecture, and bone quality. RESULTS Specimens can be imaged by micro-CT at a resolution starting at 1 μm, but in vivo human imaging is restricted to a voxel size of 82 μm (with actual spatial resolution of ~ 130 μm) due to technical limitations and radiation dose considerations. Presently, this mode is limited to peripheral skeletal regions, such as the wrist and tibia. In contrast, multidetector CT can assess the central skeleton but incurs a higher radiation burden on the subject and provides lower resolution (200-500 μm). CONCLUSIONS CT currently provides quantitative measures of bone structure and may be used for estimating bone strength mathematically. The techniques may provide clinically relevant information by enhancing our understanding of fracture risk and establishing the efficacy of antifracture for osteoporosis and other bone metabolic disorders.
Collapse
Affiliation(s)
- Andrew J. Burghardt
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California, San Francisco, Campus Box 2520, QB3 Building, 2nd Floor, Suite 203, 1700 4th Street, San Francisco, CA 94158 USA
| | - Thomas M. Link
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California, San Francisco, Campus Box 2520, QB3 Building, 2nd Floor, Suite 203, 1700 4th Street, San Francisco, CA 94158 USA
| | - Sharmila Majumdar
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California, San Francisco, Campus Box 2520, QB3 Building, 2nd Floor, Suite 203, 1700 4th Street, San Francisco, CA 94158 USA
| |
Collapse
|
50
|
Wang Q, Ghasem-Zadeh A, Wang XF, Iuliano-Burns S, Seeman E. Trabecular bone of growth plate origin influences both trabecular and cortical morphology in adulthood. J Bone Miner Res 2011; 26:1577-83. [PMID: 21312271 DOI: 10.1002/jbmr.360] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Skeletal fragility is common at metaphyseal regions of long bones. The cortices of this region are derived by coalescence of trabeculae around the periphery of the growth plate, not by periosteal apposition, as occurs in the diaphyses. We therefore hypothesized that trabecular bone in childhood predicted both cortical and trabecular morphology in adulthood. To test this hypothesis, we measured distal radial and tibial structure using high-resolution peripheral quantitative computed tomography in 61 daughter-mother pairs, mean age 12.5 years (range 7 to 19 years) and 44.1 years (range 32 to 50 years), respectively. The daughters' trabecular bone volume (BV/TV), thickness, number, and separation predicted the corresponding traits in their mothers. Their trabecular BV/TV also predicted their mothers' cortical thickness (r = 0.32, p = .02). By contrast, the daughters' cortical thickness did not predict their mothers' cortical thickness. The daughters had higher trabecular BV/TV than their mothers (mean ± SD, radius 0.134 ± 0.024 versus 0.124 ± 0.033, p = .03; tibia 0.145 ± 0.021 versus 0.135 ± 0.032, p < .01) owing to greater trabecular number, not thickness, and less trabecular separation. Abnormalities in the development of metaphyseal trabecular bone are likely to influence fragility in both trabecular and cortical bone of this region in adulthood.
Collapse
Affiliation(s)
- Qingju Wang
- Endocrine Centre, Heidelberg Repatriation Hospital, Austin Health, Department of Medicine, University of Melbourne, Heidelberg, Victoria, Australia.
| | | | | | | | | |
Collapse
|