1
|
Qiu R, Zhong W, Zhang H, Zhu Y, Yang Z, Han L. A novel micro-CT approach for in situ visualization of the spatial dynamics of mesovoids in aerobic composting piles. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 369:122329. [PMID: 39241595 DOI: 10.1016/j.jenvman.2024.122329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 07/29/2024] [Accepted: 08/28/2024] [Indexed: 09/09/2024]
Abstract
The spatial configuration of mesovoids profoundly affects the aerobic composting microenvironment, which governs vital processes such as greenhouse gas production and emission, thermal conduction, and overall composting efficiency. Nondestructive in-situ characterization of the composting spatial structure is crucial to better understand its interaction mechanism with the microenvironment. In this study, a valuable contribution to the field of composting research was made by introducing micro-computed tomography (micro-CT) tool for in situ three-dimensional (3D) visual characterizing the void structure dynamics of straw and manure compost pile units at the mesoscale. Representative samples at different composting stages derived from wheat straw and cow manure were procured by pre-embedding samplers in laboratory-based aerobic composting reactor systems. Based on an advanced Skyscan 1275 micro-CT system, scanning conditions and image processing algorithms were determined, and the void structure and their dynamic changes in the pile unit during composting were in-situ 3D visualized for the first time. The micro-CT images effectively reveal well-developed void structures exhibiting spatiotemporal dynamics during composting, and they exhibit excellent consistency with conventional macrophysical effects and wet chemical analyses. Micro-CT quantification results of the void structure parameters changes in pile unit during composting were as follows: percentage of the total voidage and the connected voidage in pile unit were in the range of 52.34%-58.56%, indicating a very suitable composting spatial structural microenvironment. This new micro-CT method provides a valuable perspective for analyzing and understanding the complex aerobic composting process.
Collapse
Affiliation(s)
- Rongbin Qiu
- Engineering Laboratory for AgroBiomass Recycling & Valorizing, College of Engineering, China Agricultural University, Box 191, Beijing, 100083, China.
| | - Weizheng Zhong
- Engineering Laboratory for AgroBiomass Recycling & Valorizing, College of Engineering, China Agricultural University, Box 191, Beijing, 100083, China.
| | - Hehu Zhang
- Engineering Laboratory for AgroBiomass Recycling & Valorizing, College of Engineering, China Agricultural University, Box 191, Beijing, 100083, China.
| | - Ying Zhu
- Engineering Laboratory for AgroBiomass Recycling & Valorizing, College of Engineering, China Agricultural University, Box 191, Beijing, 100083, China.
| | - Zengling Yang
- Engineering Laboratory for AgroBiomass Recycling & Valorizing, College of Engineering, China Agricultural University, Box 191, Beijing, 100083, China.
| | - Lujia Han
- Engineering Laboratory for AgroBiomass Recycling & Valorizing, College of Engineering, China Agricultural University, Box 191, Beijing, 100083, China.
| |
Collapse
|
2
|
Ghasemzadeh F, Mortazavi N, Mallahi M, Gharib MH, Behnampour N, Badeleh MT, Asgari N. Association between psychological stress and mandibular condyle structure: an analytical cross-sectional study. BMC Musculoskelet Disord 2024; 25:563. [PMID: 39030530 PMCID: PMC11264819 DOI: 10.1186/s12891-024-07692-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Accepted: 07/15/2024] [Indexed: 07/21/2024] Open
Abstract
OBJECTIVE The potential influence of psychological factors on temporomandibular joint disorders has been clinically documented. To date, all research examining the impact of psychological stress on the temporomandibular joint has been conducted on animals. This study aims to explore the relationship between psychological stress and the structure of the human mandibular condyle. METHODS This cross-sectional study was performed on individuals, who were referred to the radiology division of 5th Azar Hospital for head and neck Computed Tomography (CT) scans. All participants completed a perceived stress questionnaire to determine their level of stress. Bone density and cortical bone thickness were measured as indicators of mandibular condyle structure. Based on multi-slice CT scan data, bone density was calculated in the anterior, middle, and posterior mandibular condyle. The cortical bone thickness was also measured at the anterior and posterior mandibular condyle. Statistical analysis was performed in R 4.0.2 software. RESULTS Seventy individuals, aged 18-59 years, participated in this study. The CT scans revealed a decrease in Hounsfield units (HU) and bone mineral density (BMD) in both the anterior and posterior regions. However, in the high-stress group, there was no significant difference in cortical bone thickness in the anterior and posterior regions of the condyle, nor in HU and BMD in the middle region of the condyle. An inverse correlation was observed between BMD and perceived stress in the anterior, middle, and posterior regions of both condyles. CONCLUSION The current findings indicate that recent psychological stress is associated with changes in the structure of the condyle.
Collapse
Affiliation(s)
- Fatemeh Ghasemzadeh
- Dental Research Center, Golestan University of Medical Sciences, Gorgan, Iran
| | - Nazanin Mortazavi
- Dental Research Center, Golestan University of Medical Sciences, Gorgan, Iran.
| | - Mysa Mallahi
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Golestan University of Medical Sciences, Gorgan, Iran
| | - Mohammad Hadi Gharib
- Department of Radiology, School of Medicine, 5th Azar Hospital, Golestan University of Medical Sciences, Gorgan, Iran
| | - Naser Behnampour
- Health Management and Social Development Research Center, Golestan University of Medical Sciences, Gorgan, Iran
| | - Mohammad Taghi Badeleh
- Department of Psychology, School of Medicine, Golestan University of Medical Sciences, Gorgan, Iran
| | - Negar Asgari
- Department of Microbiology, School of Medicine, Golestan University of Medical Sciences, Gorgan, Iran
| |
Collapse
|
3
|
Silveira A, Greving I, Longo E, Scheel M, Weitkamp T, Fleck C, Shahar R, Zaslansky P. Deep learning to overcome Zernike phase-contrast nanoCT artifacts for automated micro-nano porosity segmentation in bone. JOURNAL OF SYNCHROTRON RADIATION 2024; 31:136-149. [PMID: 38095668 PMCID: PMC10833422 DOI: 10.1107/s1600577523009852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 11/13/2023] [Indexed: 01/09/2024]
Abstract
Bone material contains a hierarchical network of micro- and nano-cavities and channels, known as the lacuna-canalicular network (LCN), that is thought to play an important role in mechanobiology and turnover. The LCN comprises micrometer-sized lacunae, voids that house osteocytes, and submicrometer-sized canaliculi that connect bone cells. Characterization of this network in three dimensions is crucial for many bone studies. To quantify X-ray Zernike phase-contrast nanotomography data, deep learning is used to isolate and assess porosity in artifact-laden tomographies of zebrafish bones. A technical solution is proposed to overcome the halo and shade-off domains in order to reliably obtain the distribution and morphology of the LCN in the tomographic data. Convolutional neural network (CNN) models are utilized with increasing numbers of images, repeatedly validated by `error loss' and `accuracy' metrics. U-Net and Sensor3D CNN models were trained on data obtained from two different synchrotron Zernike phase-contrast transmission X-ray microscopes, the ANATOMIX beamline at SOLEIL (Paris, France) and the P05 beamline at PETRA III (Hamburg, Germany). The Sensor3D CNN model with a smaller batch size of 32 and a training data size of 70 images showed the best performance (accuracy 0.983 and error loss 0.032). The analysis procedures, validated by comparison with human-identified ground-truth images, correctly identified the voids within the bone matrix. This proposed approach may have further application to classify structures in volumetric images that contain non-linear artifacts that degrade image quality and hinder feature identification.
Collapse
Affiliation(s)
- Andreia Silveira
- Department for Restorative, Preventive and Pediatric Dentistry, Charité-Universitaetsmedizin, Berlin, Germany
| | - Imke Greving
- Institute of Materials Physics, Helmholtz-Zentrum Hereon, Geesthacht, Germany
| | - Elena Longo
- Elettra – Sincrotrone Trieste SCpA, Basovizza, Trieste, Italy
| | | | | | - Claudia Fleck
- Fachgebiet Werkstofftechnik / Chair of Materials Science and Engineering, Institute of Materials Science and Technology, Faculty III Process Sciences, Technische Universität Berlin, Berlin, Germany
| | - Ron Shahar
- Koret School of Veterinary Medicine, The Robert H. Smith Faculty of Agriculture, Food and Environmental Sciences, Hebrew University of Jerusalem, Rehovot, Israel
| | - Paul Zaslansky
- Department for Restorative, Preventive and Pediatric Dentistry, Charité-Universitaetsmedizin, Berlin, Germany
| |
Collapse
|
4
|
Jadzic J, Mijucic J, Bracanovic D, Nikolic S, Bracanovic M, Djuric M, Djonic D. Age-at-death estimation based on micro-CT assessment of pubic symphysis: Potentially new methodological approach. Forensic Sci Int 2023; 352:111851. [PMID: 37801865 DOI: 10.1016/j.forsciint.2023.111851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 08/28/2023] [Accepted: 09/28/2023] [Indexed: 10/08/2023]
Abstract
BACKGROUND Although various methods for age-at-death estimation of skeletal remains are available, this is still an unsolved issue in forensic anthropology, especially concerning elderly individuals. Moreover, the lack of population-specific methods often made age-at-death estimation unreliable in other populations. AIM Our study aimed to examine whether micro-computed tomography (micro-CT) analysis of pubic bone samples obtained from the contemporary Serbian population could be used in anthropological and forensic practice for age-at-death estimation. METHODOLOGY This study encompassed 62 pubic samples obtained from 26 adult male and 36 adult female cadaveric donors (age range: 22-91 years). Initially, staging according to the Suchey-Brooks phases was performed by two experienced investigators, followed by micro-CT assessment of pubic bone trabecular and cortical compartments (spatial resolution of the scans was 10 µm). RESULTS Our results revealed an age-associated decline in trabecular and cortical micro-architecture of elderly male and female individuals, with the most prominent changes present in trabecular bone volume fraction and total porosity of the anterior and posterior cortical surface of the pubic bone. Those parameters were used to generate age-at-death estimation equations. One sample t-test did not reveal a significant difference between estimated age-at-death and real (known) age-at-death in the overall sample (mean absolute error [MAE] of 4.76 years), female (MAE of 9.66 years) and male cadaveric donors (MAE of 6.10 years, p > 0.05). CONCLUSION Our data indicated that micro-architectural features of trabecular and cortical compartments of pubic bone could potentially be applied as an additional reliable method for age-at-death estimation in the Serbian population.
Collapse
Affiliation(s)
- Jelena Jadzic
- Center of Bone Biology, Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | - Jovana Mijucic
- Center of Bone Biology, Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | - Djurdja Bracanovic
- Department of Radiology, School of Dental Medicine, University of Belgrade, Belgrade, Serbia
| | - Slobodan Nikolic
- Center of Bone Biology, Faculty of Medicine, University of Belgrade, Belgrade, Serbia; Institute of Forensic Medicine, Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | - Milos Bracanovic
- Clinic for Emergency Surgery, Clinical Center of Serbia, Belgrade, Serbia
| | - Marija Djuric
- Center of Bone Biology, Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | - Danijela Djonic
- Center of Bone Biology, Faculty of Medicine, University of Belgrade, Belgrade, Serbia.
| |
Collapse
|
5
|
Qian W, Schmidt R, Turner JA, Bare SP, Lappe JM, Recker RR, Akhter MP. A pilot study on the nanoscale properties of bone tissue near lacunae in fracturing women. Bone Rep 2022; 17:101604. [PMID: 35874169 PMCID: PMC9304727 DOI: 10.1016/j.bonr.2022.101604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 07/09/2022] [Accepted: 07/12/2022] [Indexed: 11/17/2022] Open
Abstract
The goal of this study is to investigate the causes of osteoporosis-related skeletal fragility in postmenopausal women. We hypothesize that bone fragility in these individuals is largely due to mineral, and/or intrinsic material properties in the osteocyte lacunar/peri-lacunar regions of bone tissue. Innovative measurements with nanoscale resolution, including scanning electron microscope (SEM), an atomic force microscope that is integrated with infrared spectroscopy (AFM-IR), and nanoindentation, were used to characterize osteocyte lacunar and peri-lacunar properties in bone biopsies from fracturing (Cases) and matched (Age, BMD), non-fracturing (Controls) postmenopausal healthy women. In the peri-lacunar space, the nanoindentation results show that the modulus and hardness of the Controls are lower than the Cases. The AFM-IR results conclusively show that the mineral matrix, maturity (peak) (except in outer/far regions in Controls) were greater in Controls than in Cases. Furthermore, these results indicate that while mineral-to-matrix area ratio tend to be greater, the mineral maturity and crystallinity peak ratio "near" lacunae is greater than at regions "far" or more distance from lacunae in the Controls only. Due to the heterogeneity of bone structure, additional measurements are needed to provide more convincing evidence of altered lacunar characteristics and changes in the peri-lacunar bone as mechanisms related to postmenopausal women and fragility. Such findings would motivate new osteocyte-targeted treatments to reduce fragility fracture risks in these groups.
Collapse
Affiliation(s)
- Wen Qian
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE 68588-0526, United States of America
| | - Roman Schmidt
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE 68588-0526, United States of America
| | - Joseph A. Turner
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE 68588-0526, United States of America
| | - Sue P. Bare
- Osteoporosis Research Center, Creighton University School of Medicine, Omaha, NE 68178, United States of America
| | - Joan M. Lappe
- Osteoporosis Research Center, Creighton University School of Medicine, Omaha, NE 68178, United States of America
| | - Robert R. Recker
- Osteoporosis Research Center, Creighton University School of Medicine, Omaha, NE 68178, United States of America
| | - Mohammed P. Akhter
- Osteoporosis Research Center, Creighton University School of Medicine, Omaha, NE 68178, United States of America
| |
Collapse
|
6
|
Guo A, Zheng Y, Zhong Y, Mo S, Fang S. Effect of chitosan/inorganic nanomaterial scaffolds on bone regeneration and related influencing factors in animal models: A systematic review. Front Bioeng Biotechnol 2022; 10:986212. [PMID: 36394038 PMCID: PMC9643585 DOI: 10.3389/fbioe.2022.986212] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 10/11/2022] [Indexed: 09/19/2023] Open
Abstract
Bone tissue engineering (BTE) provides a promising alternative for transplanting. Due to biocompatibility and biodegradability, chitosan-based scaffolds have been extensively studied. In recent years, many inorganic nanomaterials have been utilized to modify the performance of chitosan-based materials. In order to ascertain the impact of chitosan/inorganic nanomaterial scaffolds on bone regeneration and related key factors, this study presents a systematic comparison of various scaffolds in the calvarial critical-sized defect (CSD) model. A total of four electronic databases were searched without publication date or language restrictions up to April 2022. The Animal Research Reporting of In Vivo Experiments 2.0 guidelines (ARRIVE 2.0) were used to assess the quality of the included studies. Moreover, the risk of bias (RoB) was evaluated via the Systematic Review Center for Laboratory Animal Experimentation (SYRCLE) tool. After the screening, 22 studies were selected. None of these studies achieved high quality or had a low RoB. In the available studies, scaffolds reconstructed bone defects in radically different extensions. Several significant factors were identified, including baseline characteristics, physicochemical properties of scaffolds, surgery details, and scanning or reconstruction parameters of micro-computed tomography (micro-CT). Further studies should focus on not only improving the osteogenic performance of the scaffolds but also increasing the credibility of studies through rigorous experimental design and normative reports.
Collapse
Affiliation(s)
| | | | | | - Shuixue Mo
- College of Stomatology, Guangxi Medical University, Nanning, China
| | - Shanbao Fang
- College of Stomatology, Guangxi Medical University, Nanning, China
| |
Collapse
|
7
|
Lucia S, Alessandro P, Giulia B, Giada F, Massimo DF, Daniele B, Fouad K, Stefano S. The bone lid technique in lateral sinus lift: a systematic review and meta-analysis. Int J Implant Dent 2022; 8:33. [PMID: 36036281 PMCID: PMC9424465 DOI: 10.1186/s40729-022-00433-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2022] [Accepted: 08/20/2022] [Indexed: 02/08/2023] Open
Abstract
Objective This systematic review aimed at assessing the effect of the repositioned bone lid on bone augmentation in lateral sinus lift in pre-clinical in vivo and clinical studies. Secondary aims were to report on the healing of the bone window and to assess the implant survival rate. Material and methods Animal and human studies comparing lateral maxillary sinus floor elevation in combination or not with the repositioned bone lid were retrieved from MEDLINE (PubMed), Web of Science and Cochrane online library. Studies published in English up to April 2022 and reporting on histological and/or radiographic outcomes were considered. Case reports, case series and reviews were excluded. A hand search was also conducted. Risk of bias was assessed and meta-analysis performed to investigate the effect of the bone lid on new bone formation. Results After screening, 5 animal studies (4 in rabbits, 1 in sheep) and 2 clinical studies (1 RCT, 1 case–control) were included. Meta-analysis confirmed a higher new bone formation in rabbits at 2 and 8 weeks using the bone lid. The two clinical studies investigated lateral sinus lift with concomitant implant placement and reported similar results and high short-term implant success rate in both test and control groups. Conclusions The meta-analysis provided moderate evidence that the repositioned bone lid favored the formation of new bone to a higher extent as compared to resorbable membranes in animal studies. Implant success seems not to be influenced by the technique in the short term.
Collapse
Affiliation(s)
- Schiavon Lucia
- Department of Neurosciences, Dentistry Section, University of Padova, Via Giustiniani 2, 35128, Padua, Italy
| | - Perini Alessandro
- Department of Neurosciences, Dentistry Section, University of Padova, Via Giustiniani 2, 35128, Padua, Italy
| | - Brunello Giulia
- Department of Neurosciences, Dentistry Section, University of Padova, Via Giustiniani 2, 35128, Padua, Italy. .,Department of Oral Surgery, University Clinic of Düsseldorf, Moorenstrasse 5, 40225, Düsseldorf, Germany.
| | - Ferrante Giada
- Department of Neurosciences, Dentistry Section, University of Padova, Via Giustiniani 2, 35128, Padua, Italy
| | - Del Fabbro Massimo
- Department of Biomedical, Surgical and Dental Sciences, Università Degli Studi di Milano, Via Commenda 10, 20122, Milan, Italy.,Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Francesco Sforza, 35, 20122, Milan, Italy
| | | | - Khoury Fouad
- Department of Oral and Maxillofacial Surgery, University of Munster, Waldeyerstr. 30, 48149, Munster, Germany.,International Dental Implant Center, Private Clinic Schloss Schellenstein, Am Schellenstein 1, 59939, Olsberg, Germany
| | - Sivolella Stefano
- Department of Neurosciences, Dentistry Section, University of Padova, Via Giustiniani 2, 35128, Padua, Italy
| |
Collapse
|
8
|
Li Y, Lu S, Zhang Y, Li J, Zhang J, Zhang C, Xiong L. Multifunctional Imaging of Vessels, Brown Adipose Tissue, and Bones in the Visible and Second Near-infrared Region Using Dual-Emitting Polymer Dots. ACS APPLIED MATERIALS & INTERFACES 2022; 14:37504-37513. [PMID: 35970519 DOI: 10.1021/acsami.2c10420] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Dual-emitting polymer dots (dual-Pdots) in the visible and second near-infrared (NIR-II) region can facilitate the high-resolution imaging of the fine structure and improve the signal-to-noise ratio in in vivo imaging. Herein, combining high brightness of Pdots and multi-scale imaging, we synthesized dual-Pdots using a simple nano-coprecipitation method and performed multi-functional imaging of vessels, brown adipose tissue, and bones. Results showed that in vivo blood vessel imaging had a high resolution of up to 5.9 μm and bone imaging had a signal-to-noise ratio of 3.9. Moreover, dual-Pdots can accumulate in the interscapular brown adipose tissue within 2 min with a signal-to-noise ratio of 5.8. In addition, the prepared dual-Pdots can image the lymphatic valves and the frequency of contraction. Our study provides a feasible method of using Pdots as nanoprobes for multi-scale imaging in the fields of metabolic disorders, skeletal system diseases, and circulatory systems.
Collapse
Affiliation(s)
- Yuqiao Li
- Shanghai Med-X Engineering Center for Medical Equipment and Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, P. R. China
| | - Shuting Lu
- Shanghai Med-X Engineering Center for Medical Equipment and Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, P. R. China
| | - Yufan Zhang
- Shanghai Med-X Engineering Center for Medical Equipment and Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, P. R. China
| | - Jingru Li
- Shanghai Med-X Engineering Center for Medical Equipment and Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, P. R. China
| | - Juxiang Zhang
- Shanghai Med-X Engineering Center for Medical Equipment and Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, P. R. China
| | - Chunfu Zhang
- Shanghai Med-X Engineering Center for Medical Equipment and Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, P. R. China
| | - Liqin Xiong
- Shanghai Med-X Engineering Center for Medical Equipment and Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, P. R. China
| |
Collapse
|
9
|
Characterizing the Mechanical Behavior of Bone and Bone Surrogates in Compression Using pQCT. MATERIALS 2022; 15:ma15145065. [PMID: 35888531 PMCID: PMC9320168 DOI: 10.3390/ma15145065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 07/12/2022] [Accepted: 07/18/2022] [Indexed: 01/27/2023]
Abstract
Many axial and appendicular skeleton bones are subjected to repetitive loading during daily activities. Until recently, the structural analysis of fractures has been limited to 2D sections, and the dynamic assessment of fracture progression has not been possible. The structural failure was analyzed using step-wise micro-compression combined with time-lapsed micro-computed tomographic imaging. The structural failure was investigated in four different sample materials (two different bone surrogates, lumbar vertebral bodies from bovine and red deer). The samples were loaded in different force steps based on uniaxial compression tests. The micro-tomography images were used to create three-dimensional models from which various parameters were calculated that provide information about the structure and density of the samples. By superimposing two 3D images and calculating the different surfaces, it was possible to precisely analyze which trabeculae failed in which area and under which load. According to the current state of the art, bone mineral density is usually used as a value for bone quality, but the question can be raised as to whether other values such as trabecular structure, damage accumulation, and bone mineralization can predict structural competence better than bone mineral density alone.
Collapse
|
10
|
JI W, CHEN M, JI H. The calcium supplementation effect of calcium-binding oligopeptides from bonito (Auxis thazard) hydrolysate in rats. FOOD SCIENCE AND TECHNOLOGY 2022. [DOI: 10.1590/fst.101621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Affiliation(s)
- Wei JI
- Guangdong University of Education, China
| | | | - Hongwu JI
- Guangdong Ocean University, China; Guangdong Ocean University, China
| |
Collapse
|
11
|
Aróstica R, Aguilera A, Osses A, Minonzio JG. A simplified homogenization model applied to viscoelastic behavior of cortical bone at ultrasonic frequencies. J Biomech 2021; 131:110868. [PMID: 34923295 DOI: 10.1016/j.jbiomech.2021.110868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Revised: 11/12/2021] [Accepted: 11/16/2021] [Indexed: 10/19/2022]
Abstract
Cortical bone is a complex multiscale medium and its study is of importance for clinical fracture prevention. In particular, cortical attenuation is known to be linked with shock energy absorption and ability to resist fracture. However, the links between cortical bone absorption and its multiscale structure are still not well understood. This work is about the use of homogenized tensors in order to characterize the viscoelastic behavior of cortical bone at ultrasonic frequencies, i.e., about 0.1 to 10 MHz. Such tensors are derived from the cell problem via two-scale homogenization theory for linear elastic and Kelvin-Voigt viscoelastic descriptions. The elliptic formulations obtained from the cell problems are implemented within the range of medically-observed porosities. Microstructure is assessed considering cubic cells with cylindrical inclusion and transverse isotropic assumption. A simplified model, adding one temporal parameter τ per phase, allows a good agreement with experimental data. The corresponding attenuation is proportional to the square of the frequency, in agreement with Kramer-Kronig relations. This development is proposed in the context of robust clinical inverse problem approaches using a restricted number of parameter. Two main properties for the material filling the pores are adjusted and discussed: absorption and shear contribution. Best agreement with experimental data is observed for material inside the pores being solid and highly attenuating.
Collapse
Affiliation(s)
- Reidmen Aróstica
- Departamento de Ingeniería Matemática and Center for Mathematical Modeling UMI CNRS 2807, FCFM, Universidad de Chile, Av. Beaucheff 851, Santiago, Chile.
| | - Ana Aguilera
- Escuela de Ingeniería Informática, Universidad de Valparaíso, Valparaíso, Chile.
| | - Axel Osses
- Departamento de Ingeniería Matemática and Center for Mathematical Modeling UMI CNRS 2807, FCFM, Universidad de Chile, Av. Beaucheff 851, Santiago, Chile; Millenium Nucleus in Cardiovascular Magnetic Resonance, Cardio MR, Chile; Millenium Nucleus Applied Control and Inverse Problems, ACIP, Chile.
| | - Jean-Gabriel Minonzio
- Escuela de Ingeniería Informática, Universidad de Valparaíso, Valparaíso, Chile; Centro de Investigación y Desarrollo en Ingeniería en Salud, Universidad de Valparaíso, Valparaíso, Chile.
| |
Collapse
|
12
|
Yarrow JF, Wnek RD, Conover CF, Reynolds MC, Buckley KH, Kura JR, Sutor TW, Otzel DM, Mattingly AJ, Croft S, Aguirre JI, Borst SE, Beck DT, McCullough DJ. Bone loss after severe spinal cord injury coincides with reduced bone formation and precedes bone blood flow deficits. J Appl Physiol (1985) 2021; 131:1288-1299. [PMID: 34473574 DOI: 10.1152/japplphysiol.00444.2021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Diminished bone perfusion develops in response to disuse and has been proposed as a mechanism underlying bone loss. Bone blood flow (BF) has not been investigated within the unique context of severe contusion spinal cord injury (SCI), a condition that produces neurogenic bone loss that is precipitated by disuse and other physiological consequences of central nervous system injury. Herein, 4-mo-old male Sprague-Dawley rats received T9 laminectomy (SHAM) or laminectomy with severe contusion SCI (n = 20/group). Time course assessments of hindlimb bone microstructure and bone perfusion were performed in vivo at 1- and 2-wk postsurgery via microcomputed tomography (microCT) and intracardiac microsphere infusion, respectively, and bone turnover indices were determined via histomorphometry. Both groups exhibited cancellous bone loss beginning in the initial postsurgical week, with cancellous and cortical bone deficits progressing only in SCI thereafter. Trabecular bone deterioration coincided with uncoupled bone turnover after SCI, as indicated by signs of ongoing osteoclast-mediated bone resorption and a near-complete absence of osteoblasts and cancellous bone formation. Bone BF was not different between groups at 1 wk, when both groups displayed bone loss. In comparison, femur and tibia perfusion was 30%-40% lower in SCI versus SHAM at 2 wk, with the most pronounced regional BF deficits occurring at the distal femur. Significant associations existed between distal femur BF and cancellous and cortical bone loss indices. Our data provide the first direct evidence indicating that bone BF deficits develop in response to SCI and temporally coincide with suppressed bone formation and with cancellous and cortical bone deterioration.NEW & NOTEWORTHY We provide the first direct evidence indicating femur and tibia blood flow (BF) deficits exist in conscious (awake) rats after severe contusion spinal cord injury (SCI), with the distal femur displaying the largest BF deficits. Reduced bone perfusion temporally coincided with unopposed bone resorption, as indicated by ongoing osteoclast-mediated bone resorption and a near absence of surface-level bone formation indices, which resulted in severe cancellous and cortical microstructural deterioration after SCI.
Collapse
Affiliation(s)
- Joshua F Yarrow
- Research Service, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, Florida.,Brain Rehabilitation Research Center, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, Florida.,Division of Endocrinology, Diabetes, and Metabolism, University of Florida College of Medicine, Gainesville, Florida
| | - Russell D Wnek
- Research Service, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, Florida
| | - Christine F Conover
- Research Service, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, Florida
| | - Michael C Reynolds
- Research Service, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, Florida
| | - Kinley H Buckley
- Research Service, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, Florida
| | - Jayachandra R Kura
- Research Service, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, Florida
| | - Tommy W Sutor
- Research Service, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, Florida
| | - Dana M Otzel
- Brain Rehabilitation Research Center, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, Florida
| | - Alex J Mattingly
- Geriatrics Research, Education, and Clinical Center, North Florida/South Georgia Veterans Health System, Gainesville, Florida
| | - Summer Croft
- Department of Physiological Sciences, University of Florida College of Veterinary Medicine, Gainesville, Florida
| | - J Ignacio Aguirre
- Department of Physiological Sciences, University of Florida College of Veterinary Medicine, Gainesville, Florida
| | - Stephen E Borst
- Research Service, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, Florida
| | - Darren T Beck
- Department of Cell Biology and Physiology, Edward Via College of Osteopathic Medicine-Auburn Campus, Auburn, Alabama
| | - Danielle J McCullough
- Department of Cell Biology and Physiology, Edward Via College of Osteopathic Medicine-Auburn Campus, Auburn, Alabama
| |
Collapse
|
13
|
Subchondral Bone Relative Area and Density in Human Osteoarthritic Femoral Heads Assessed with Micro-CT before and after Mechanical Embedding of the Innovative Multi-Spiked Connecting Scaffold for Resurfacing THA Endoprostheses: A Pilot Study. J Clin Med 2021; 10:jcm10132937. [PMID: 34208953 PMCID: PMC8268800 DOI: 10.3390/jcm10132937] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/27/2021] [Accepted: 06/28/2021] [Indexed: 12/19/2022] Open
Abstract
The multi-spiked connecting scaffold (MSC-Scaffold) prototype is the essential innovation in the fixation of components of resurfacing total hip arthroplasty (THRA) endoprostheses in the subchondral trabecular bone. We conducted the computed micro-tomography (micro-CT) assessment of the subchondral trabecular bone microarchitecture before and after the MSC-Scaffold embedding in femoral heads removed during long-stem endoprosthesis total hip arthroplasty (THA) of different bone densities from 4 patients with hip osteoarthritis (OA). The embedding of the MSC-Scaffold in subchondral trabecular bone causes the change in its relative area (BA/TA, bone area/total area ratio) ranged from 18.2% to 24.7% (translating to the calculated density ρB relative change 11.1–14.4%, and the compressive strength S relative change 75.3–122.7%) regardless of its initial density (before the MSC-Scaffold embedding). The densification of the trabecular microarchitecture of subchondral trabecular bone due to the MSC-Scaffold initial embedding gradually decreases with the increasing distance from the apexes of the MSC-Scaffold’s spikes while the spatial extent of this subchondral trabecular bone densification ranged from 1.5 to 2.5 mm (which is about half the height of the MSC-Scaffold’s spikes). It may be suggested, despite the limited number of examined femoral heads, that: (1) the magnitude of the effect of the MSC-Scaffold embedding on subchondral trabecular bone densification may be a factor contributing to the maintenance of the MSC-Scaffold also for decreased initial bone density values, (2) the deeper this effect of the subchondral trabecular bone densification, the better strength of subchondral trabecular bone, and as consequence, the better post-operative embedding of the MSC-Scaffold in the bone should be expected.
Collapse
|
14
|
Koudelka P, Kytyr D, Fila T, Sleichrt J, Rada V, Zlamal P, Benes P, Bendova V, Kumpova I, Vopalensky M. A Method for Evaluation the Fatigue Microcrack Propagation in Human Cortical Bone Using Differential X-ray Computed Tomography. MATERIALS 2021; 14:ma14061370. [PMID: 33799895 PMCID: PMC8001655 DOI: 10.3390/ma14061370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 03/04/2021] [Accepted: 03/08/2021] [Indexed: 11/16/2022]
Abstract
Fatigue initiation and the propagation of microcracks in a cortical bone is an initial phase of damage development that may ultimately lead to the formation of macroscopic fractures and failure of the bone. In this work, a time-resolved high-resolution X-ray micro-computed tomography (CT) was performed to investigate the system of microcracks in a bone sample loaded by a simulated gait cycle. A low-cycle (1000 cycles) fatigue loading in compression with a 900 N peak amplitude and a 0.4 Hz frequency simulating the slow walk for the initialization of the internal damage of the bone was used. An in-house developed laboratory X-ray micro-CT imaging system coupled with a compact loading device were employed for the in situ uni-axial fatigue experiments reaching a μ2μm effective voxel size. To reach a comparable quality of the reconstructed 3D images with the SEM microscopy, projection-level corrections and focal spot drift correction were performed prior to the digital volume correlation and evaluation using differential tomography for the identification of the individual microcracks in the microstructure. The microcracks in the intact bone, the crack formation after loading, and the changes in the topology of the microcracks were identified on a volumetric basis in the microstructure of the bone.
Collapse
|