1
|
Comparison Between Effects of Galvanic and Vibration-Based Vestibular Stimulation on Postural Control and Gait Performance in Healthy Participants: A Systematic Review of Cross-Sectional Studies. Ann Biomed Eng 2024; 52:757-793. [PMID: 38148425 DOI: 10.1007/s10439-023-03425-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 12/08/2023] [Indexed: 12/28/2023]
Abstract
Electricity and vibration were two commonly used physical agents to provide vestibular stimulation in previous studies. This study aimed to systematically review the effects of galvanic (GVS) and vibration-based vestibular stimulation (VVS) on gait performance and postural control in healthy participants. Five bioscience and engineering databases, including MEDLINE via PubMed, CINAHL via EBSCO, Cochrane Library, Scopus, and Embase, were searched until March 19th, 2023. Studies published between 2000 and 2023 in English involving GVS and VVS related to gait performance and postural control were included. The procedure was followed via the Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines. The methodological quality of included studies was assessed using the NIH study quality assessment tool for observational cohort and cross-sectional studies. A total of 55 cross-sectional studies met the inclusion criteria and were included in this study. Five studies were good-quality while 49 were moderate-quality and 1 was poor-quality. There were 50 included studies involving GVS and 5 included studies involving VVS. GVS and VVS utilized different physical agents to provide vestibular stimulation and demonstrated similar effects on vestibular perception. Supra-threshold GVS and VVS produced vestibular perturbation that impaired gait performance and postural control, while sub-threshold GVS and VVS induced stochastic resonance phenomenon that led to an improvement. Bilateral vestibular stimulation demonstrated a greater effect on gait and posture than unilateral vestibular stimulation. Compared to GVS, VVS had the characteristics of better tolerance and fewer side effects, which may substitute GVS to provide more acceptable vestibular stimulation.
Collapse
|
2
|
Repetitive Low-Intensity Vestibular Noise Stimulation Partly Reverses Behavioral and Brain Activity Changes following Bilateral Vestibular Loss in Rats. Biomolecules 2023; 13:1580. [PMID: 38002261 PMCID: PMC10669117 DOI: 10.3390/biom13111580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 10/18/2023] [Accepted: 10/22/2023] [Indexed: 11/26/2023] Open
Abstract
Low-intensity noisy galvanic vestibular stimulation (nGVS) can improve static and dynamic postural deficits in patients with bilateral vestibular loss (BVL). In this study, we aimed to explore the neurophysiological and neuroanatomical substrates underlying nGVS treatment effects in a rat model of BVL. Regional brain activation patterns and behavioral responses to a repeated 30 min nGVS treatment in comparison to sham stimulation were investigated by serial whole-brain 18F-FDG-PET measurements and quantitative locomotor assessments before and at nine consecutive time points up to 60 days after the chemical bilateral labyrinthectomy (BL). The 18F-FDG-PET revealed a broad nGVS-induced modulation on regional brain activation patterns encompassing biologically plausible brain networks in the brainstem, cerebellum, multisensory cortex, and basal ganglia during the entire observation period post-BL. nGVS broadly reversed brain activity adaptions occurring in the natural course post-BL. The parallel behavioral locomotor assessment demonstrated a beneficial treatment effect of nGVS on sensory-ataxic gait alterations, particularly in the early stage of post-BL recovery. Stimulation-induced locomotor improvements were finally linked to nGVS brain activity responses in the brainstem, hemispheric motor, and limbic networks. In conclusion, combined 18F-FDG-PET and locomotor analysis discloses the potential neurophysiological and neuroanatomical substrates that mediate previously observed therapeutic nGVS effects on postural deficits in patients with BVL.
Collapse
|
3
|
Optimal Design of Galvanic Vestibular Stimulation for Patients with Vestibulopathy and Cerebellar Disorders. Brain Sci 2023; 13:1333. [PMID: 37759934 PMCID: PMC10526825 DOI: 10.3390/brainsci13091333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 09/02/2023] [Accepted: 09/15/2023] [Indexed: 09/29/2023] Open
Abstract
OBJECTIVES Galvanic vestibular stimulation (GVS) has shown positive outcomes in various neurological and psychiatric disorders, such as enhancing postural balance and cognitive functions. In order to expedite the practical application of GVS in clinical settings, our objective was to determine the best GVS parameters for patients with vestibulopathy and cerebellar disorders using optimal design calculation. METHODS A total of 31 patients (26 males, mean age 57.03 ± 14.75 years, age range 22-82 years) with either unilateral or bilateral vestibulopathy (n = 18) or cerebellar ataxia (n = 13) were enrolled in the study. The GVS intervention included three parameters, waveform (sinusoidal, direct current [DC], and noisy), amplitude (0.4, 0.8, and 1.2 mA), and duration of stimulation (5 and 30 min), resulting in a total of 18 GVS intervention modes as input variables. To evaluate the effectiveness of GVS, clinical vertigo and gait assessments were conducted using the Dizziness Visual Analogue Scale (D-VAS), Activities-specific Balance Confidence Scale (ABC), and Scale for Assessment and Rating of Ataxia (SARA) as output variables. Optimal design and local sensitivity analysis were employed to determine the most optimal GVS modes. RESULTS Patients with unilateral vestibulopathy experienced the most favorable results with either noisy or sinusoidal GVS at 0.4 mA amplitude for 30 min, followed by DC GVS at 0.8 mA amplitude for 5 min. Noisy GVS at 0.8 or 0.4 mA amplitude for 30 min demonstrated the most beneficial effects in patients with bilateral vestibulopathy. For patients with cerebellar ataxia, the optimal choices were noisy GVS with 0.8 or 0.4 mA amplitude for 5 or 30 min. CONCLUSIONS This study is the first to utilize design optimization methods to identify the GVS stimulation parameters that are tailored to individual-specific characteristics of dizziness and imbalance. A sensitivity analysis was carried out along with the optimal design to offset the constraints of a limited sample size, resulting in the identification of the most efficient GVS modes for patients suffering from vestibular and cerebellar disorders.
Collapse
|
4
|
Training augmentation using additive sensory noise in a lunar rover navigation task. Front Neurosci 2023; 17:1180314. [PMID: 37424995 PMCID: PMC10326282 DOI: 10.3389/fnins.2023.1180314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Accepted: 05/31/2023] [Indexed: 07/11/2023] Open
Abstract
Background The uncertain environments of future space missions means that astronauts will need to acquire new skills rapidly; thus, a non-invasive method to enhance learning of complex tasks is desirable. Stochastic resonance (SR) is a phenomenon where adding noise improves the throughput of a weak signal. SR has been shown to improve perception and cognitive performance in certain individuals. However, the learning of operational tasks and behavioral health effects of repeated noise exposure aimed to elicit SR are unknown. Objective We evaluated the long-term impacts and acceptability of repeated auditory white noise (AWN) and/or noisy galvanic vestibular stimulation (nGVS) on operational learning and behavioral health. Methods Subjects (n = 24) participated in a time longitudinal experiment to access learning and behavioral health. Subjects were assigned to one of our four treatments: sham, AWN (55 dB SPL), nGVS (0.5 mA), and their combination to create a multi-modal SR (MMSR) condition. To assess the effects of additive noise on learning, these treatments were administered continuously during a lunar rover simulation in virtual reality. To assess behavioral health, subjects completed daily, subjective questionnaires related to their mood, sleep, stress, and their perceived acceptance of noise stimulation. Results We found that subjects learned the lunar rover task over time, as shown by significantly lower power required for the rover to complete traverses (p < 0.005) and increased object identification accuracy in the environment (p = 0.05), but this was not influenced by additive SR noise (p = 0.58). We found no influence of noise on mood or stress following stimulation (p > 0.09). We found marginally significant longitudinal effects of noise on behavioral health (p = 0.06) as measured by strain and sleep. We found slight differences in stimulation acceptability between treatment groups, and notably nGVS was found to be more distracting than sham (p = 0.006). Conclusion Our results suggest that repeatedly administering sensory noise does not improve long-term operational learning performance or affect behavioral health. We also find that repetitive noise administration is acceptable in this context. While additive noise does not improve performance in this paradigm, if it were used for other contexts, it appears acceptable without negative longitudinal effects.
Collapse
|
5
|
CCR5-Δ32 polymorphism-a possible protective factor from gait impairment amongst post-stroke patients. Eur J Neurol 2023; 30:692-701. [PMID: 36380716 PMCID: PMC10107159 DOI: 10.1111/ene.15637] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 11/08/2022] [Accepted: 11/10/2022] [Indexed: 11/17/2022]
Abstract
BACKGROUND AND PURPOSE Stroke and small vessel disease cause gait disturbances and falls. The naturally occurring loss-of-function mutation in the C-C chemokine receptor 5 gene (CCR5-Δ32) has recently been reported as a protective factor in post-stroke motor and cognitive recovery. We sought to examine whether it also influences gait and balance measures up to 2 years after stroke. METHOD Participants were 575 survivors of first-ever, mild-moderate ischaemic stroke or transient ischaemic attack from the TABASCO prospective study, who underwent a 3 T magnetic resonance imaging at baseline and were examined by a multi-professional team 6, 12 and 24 months after the event, using neurological, neuropsychological and mobility examinations. Gait rhythm and the timing of the gait cycle were measured by force-sensitive insoles. CCR5-Δ32 status and gait measures were available for 335 patients. RESULTS CCR5-Δ32 carriers (16.4%) had higher gait speed and decreased (better) stride and swing time variability 6 and 12 months after the index event compared to non-carriers (p < 0.01 for all). The association remained significant after adjustment for age, gender, education, ethnicity and stroke severity. CONCLUSIONS Significant associations were found between gait measurements and CCR5-Δ32 loss-of-function mutation amongst stroke survivors. This is the first study showing that genetic predisposition may predict long-term gait function after ischaemic stroke.
Collapse
|
6
|
Effect of galvanic vestibular stimulation applied at the onset of stance on muscular activity and gait cycle duration in healthy individuals. Front Neural Circuits 2023; 16:1065647. [PMID: 36845254 PMCID: PMC9946991 DOI: 10.3389/fncir.2022.1065647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 12/28/2022] [Indexed: 02/11/2023] Open
Abstract
Locomotion requires the complex involvement of the spinal and supraspinal systems. So far, the role of vestibular input in gait has been assessed mainly with respect to gait stability. The noninvasive technique of galvanic vestibular stimulation (GVS) has been reported to decrease gait variability and increase gait speed, but the extent of its effect on spatiotemporal gait parameters is not fully known. Objective: Characterize vestibular responses during gait and determine the influence of GVS on cycle duration in healthy young participants. Methods: Fifteen right-handed individuals participated in the study. Electromyography (EMG) recordings of the bilateral soleus (SOL) and tibialis anterior muscles (TA) were performed. First, to determine stimulation intensity, an accelerometer placed on the vertex recorded the amplitude of the head tilts evoked by the GVS (1-4 mA, 200 ms) to establish a motor threshold (T). Second, while participants walked on a treadmill, GVS was applied at the onset of the stance phase during the treadmill gait with an intensity of 1 and 1.5 T with the cathode behind the right (RCathode) or left ear (LCathode). EMG traces were rectified, averaged (n = 30 stimuli), and analyzed. Latency, duration, and amplitude of vestibular responses as well as the mean duration of the gait cycles were measured. Results: GVS mainly induced long-latency responses in the right SOL, right TA and left TA. Only short-latency responses were triggered in the left SOL. Responses in the right SOL, left SOL and left TA were polarity dependent, being facilitatory with RCathode and inhibitory with LCathode, whereas responses in the right TA remained facilitatory regardless of the polarity. With the RCathode configuration, the stimulated cycle was prolonged compared with the control cycle at both 1 and 1.5 T, due to prolonged left SOL and TA EMG bursts, but no change was observed in right SOL and TA. With LCathode, GVS did not modify the cycle duration. Conclusion: During gait, a brief, low-intensity GVS pulse delivered at the right stance onset induced mainly long-latency polarity-dependent responses. Furthermore, a RCathode configuration increased the duration of the stimulated gait cycle by prolonging EMG activity on the anodic side. A similar approach could be explored to influence gait symmetry in individuals with neurological impairment.
Collapse
|
7
|
Inter-day and intra-day variations in effective intensity of noisy galvanic vestibular stimulation to improve postural stability in bilateral vestibulopathy. J Vestib Res 2023; 33:423-429. [PMID: 37840520 DOI: 10.3233/ves-230060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2023]
Abstract
BACKGROUND The reproducibility of the effective intensity of noisy galvanic vestibular stimulation (nGVS) to improve postural stability is not well known. OBJECTIVE We aimed to investigate inter-day and intra-day variations in effective intensity in patients with bilateral vestibulopathy (BVP). METHODS Thirteen BVP patients were measured for center-of-pressure movements in the standing posture at five time points: morning of the first test day, morning and evening of the second test day, and morning and evening of the third test day. The mean velocity, the envelopment area, and the root mean square were measured in the eyes-closed condition for 30 s during nGVS application ranging from 0 to 1000μA. The effective intensity was defined as the intensity at which all the three parameters measured during the stimulation were simultaneously smaller than the values at baseline (0μA). RESULTS Seven of the 13 patients had a common effective intensity throughout the three test days. Six patients on the second test day and five patients on the third test day had no common effective intensity between morning and evening. CONCLUSIONS The effective intensity of nGVS changes depending on the time during the day as well as between the days.
Collapse
|
8
|
Scoping out noisy galvanic vestibular stimulation: a review of the parameters used to improve postural control. Front Neurosci 2023; 17:1156796. [PMID: 37205050 PMCID: PMC10187481 DOI: 10.3389/fnins.2023.1156796] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 04/04/2023] [Indexed: 05/21/2023] Open
Abstract
Objective Noisy galvanic vestibular stimulation (nGVS) has been used to facilitate vestibular function and improve gait and balance in people with poor postural control. The aim of this scoping review is to collate, summarize and report on the nGVS parameters that have been used to augment postural control. Method A systematic scoping review was conducted up to December 2022. Data were extracted and synthesized from 31 eligible studies. Key nGVS parameters were identified, and the importance of these parameters and their influence on postural control evaluated. Results A range of nGVS parameters have been used to augment postural control, including; noise waveform, amplitude, frequency band, duration of stimulation, method of amplitude optimization, size and composition of electrodes and the electrode skin interface. Conclusion Systematic evaluation of the individual parameters that can be manipulated in the nGVS waveform identified that a broad array of settings have been utilized in each parameter across the studies. Choices made around the electrode and electrode-skin interface, as well as the amplitude, frequency band, duration and timing of the waveform are likely to influence the efficacy of nGVS. The ability to draw robust conclusions about the selection of optimal nGVS parameters to improve postural control, is hindered by a lack of studies that directly compare parameter settings or consider the variability in individuals' response to nGVS. We propose a guideline for the accurate reporting of nGVS parameters, as a first step toward establishing standardized stimulation protocols.
Collapse
|
9
|
[Bilateral peripheral vestibulopathy]. Zh Nevrol Psikhiatr Im S S Korsakova 2023; 123:24-30. [PMID: 37084361 DOI: 10.17116/jnevro202312304124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/23/2023]
Abstract
Bilateral vestibulopathy is a relatively widespread and at the same time rarely diagnosed cause of chronic postural instability. Numerous toxic factors, dysmetabolic, autoimmune and neurodegenerative processes can lead to this condition. The main clinical manifestations of bilateral vestibulopathy are balance disorders and visual disturbances (oscillopsia), which can significantly increase the risks of falls in such patients. In addition, cognitive and affective disorders, which also reduce the quality of life in patients with bilateral vestibulopathy, have been described and actively studied in recent years. The diagnosis of bilateral vestibulopathy is based on the results of a clinical neurovestibular study, including a dynamic visual acuity test and a Halmagyi test. A video head impulse test, a bithermal caloric test and a sinusoidal rotation test are used as instrumental methods confirming the dysfunction of the peripheral vestibular system. However, they are still not widespread in neurological practice. Treatment of bilateral vestibulopathy is reduced to vestibular rehabilitation. Encouraging results have been obtained in a number of studies using galvanic vestibular stimulation and the use of vestibular implants. In addition, cognitive rehabilitation methods are currently being developed, which presumably can also improve compensation for bilateral vestibular loss.
Collapse
|
10
|
Phase-dependent modulation of the vestibular-cerebellar network via combined alternating current stimulation influences human locomotion and posture. Front Neurosci 2022; 16:1057021. [PMID: 36590300 PMCID: PMC9795064 DOI: 10.3389/fnins.2022.1057021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 11/28/2022] [Indexed: 12/15/2022] Open
Abstract
Background Human locomotion induces rhythmic movements of the trunk and head. Vestibular signaling is relayed to multiple regions in the brainstem and cerebellum, and plays an essential role in maintaining head stability. However, how the vestibular-cerebellar network contributes to the rhythmic locomotor pattern in humans is unclear. Transcranial alternating current stimulation (tACS) has been used to investigate the effects of the task-related network between stimulation regions in a phase-dependent manner. Here, we investigated the relationship between the vestibular system and the cerebellum during walking imagery using combined tACS over the left cerebellum and alternating current galvanic vestibular stimulation (AC-GVS). Methods In Experiment 1, we tested the effects of AC-GVS alone at around individual gait stride frequencies. In Experiment 2, we then determined the phase-specificity of combined stimulation at the gait frequency. Combined stimulation was applied at in-phase (0° phase lag) or anti-phase (180° phase lag) between the left vestibular and left cerebellar stimulation, and the sham stimulation. We evaluated the AC-GVS-induced periodic postural response during walking imagery or no-imagery using the peak oscillatory power on the angular velocity signals of the head in both experiments. In Experiment 2, we also examined the phase-locking value (PLV) between the periodic postural responses and the left AC-GVS signals to estimate entrainment of the postural response by AC-GVS. Results AC-GVS alone induced the periodic postural response in the yaw and roll axes, but no interactions with imagery walking were observed in Experiment 1 (p > 0.05). By contrast, combined in-phase stimulation increased yaw motion (0.345 ± 0.23) compared with sham (-0.044 ± 0.19) and anti-phase stimulation (-0.066 ± 0.18) during imaginary walking (in-phase vs. other conditions, imagery: p < 0.05; no-imagery: p ≥ 0.125). Furthermore, there was a positive correlation between the yaw peak power of actual locomotion and in-phase stimulation in the imagery session (imagery: p = 0.041; no-imagery: p = 0.177). Meanwhile, we found no imagery-dependent effects in roll peak power or PLV, although in-phase stimulation enhanced roll motion and PLV in Experiment 2. Conclusion These findings suggest that combined stimulation can influence vestibular-cerebellar network activity, and modulate postural control and locomotion systems in a temporally sensitive manner. This novel combined tACS/AC-GVS stimulation approach may advance development of therapeutic applications.
Collapse
|
11
|
A portable and low-cost solution for real-time manipulation of the vestibular sense. J Neurosci Methods 2022; 382:109709. [PMID: 36116537 DOI: 10.1016/j.jneumeth.2022.109709] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 09/02/2022] [Accepted: 09/06/2022] [Indexed: 01/05/2023]
Abstract
BACKGROUND The vestibular system encodes head motion in space which is naturally accompanied by other sensory cues. Electrical stimuli, applied across the mastoid processes, selectively activate primary vestibular afferents which has spurred clinical and biomedical applications of electrical vestibular stimulation (EVS). When properly matched to head motion, EVS may also manipulate the closed-loop relationship between actions and vestibular feedback to reveal the mechanisms of sensorimotor recalibration and learning. NEW METHOD We designed a portable, low-cost real-time EVS system using an Arduino microcontroller programmed through Simulink that provides electrical currents based on head angular motion. We used well-characterized vestibular afferent physiological responses to head angular velocity and electrical current to compute head-motion equivalent of real-time modulatory EVS currents. We also examined if our system induced recalibration of the vestibular system during human balance control. RESULTS Our system operated at 199.997 Hz ( ± 0.005 Hz) and delivered head-motion-equivalent electrical currents with ∼10 ms delay. The output driving the current stimulator matched the implemented linear model for physiological vestibular afferent dynamics with minimal background noise (<0.2% of ± 10 V range). Participants recalibrated to the modulated closed-loop vestibular feedback using visual cues during standing balance, replicating earlier findings. COMPARISON WITH EXISTING METHODS EVS is typically used to impose external perturbations that are independent of one's own movement. We provided a solution using open-source hardware to implement a real-time, physiology based, and task-relevant vestibular modulations using EVS. CONCLUSIONS Our portable, low-cost vestibular modulation system will make physiological closed-loop vestibular manipulations more accessible thus encouraging novel investigations and biomedical applications of EVS.
Collapse
|
12
|
The effect of galvanic vestibular stimulation on postural balance in Parkinson's disease: A systematic review and meta-analysis. J Neurol Sci 2022; 442:120414. [PMID: 36116217 DOI: 10.1016/j.jns.2022.120414] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 08/08/2022] [Accepted: 09/05/2022] [Indexed: 11/21/2022]
Abstract
People with Parkinson's disease (PD) develop postural imbalance and falls. Galvanic Vestibular Stimulation (GVS) may potentially improve postural balance in humans and hence reduce falls in PD. This systematic review and meta-analysis investigate the effects of GVS on postural balance in PD. Six separate databases and research registers were searched for cross-over design trials that evaluated the effects of GVS on postural balance in PD. We used standardized mean difference (Hedges' g) as a measure of effect size in all studies. We screened 223 studies, evaluated 14, of which five qualified for the meta-analysis. Among n = 40 patients in five studies (range n = 5 to 13), using a fixed effects model we found an effect size estimate of g = 0.43 (p < 0.001, 95% CI [0.29,0.57]). However, the test for residual heterogeneity was significant (p < 0.001), thus we used a random effects model and found a pooled effect size estimate of 0.62 (p > 0.05, 95% CI [- 0.17, 1.41], I2 = 96.21%). Egger's test was not significant and thus trim and funnel plot indicated no bias. To reduce heterogeneity, we performed sensitivity analysis and by removing one outlier study (n = 7 patients), we found an effect size estimate of 0.16 (p < 0.05, 95% CI [0.01, 0.31], I2 = 0%). Our meta-analysis found GVS has a favourable effect on postural balance in PD patients, but due to limited literature and inconsistent methodologies, this favourable effect must be interpreted with caution.
Collapse
|
13
|
Efficacy of nGVS to improve postural stability in people with bilateral vestibulopathy: A systematic review and meta-analysis. Front Neurosci 2022; 16:1010239. [PMID: 36248647 PMCID: PMC9553993 DOI: 10.3389/fnins.2022.1010239] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 08/24/2022] [Indexed: 11/25/2022] Open
Abstract
Objective Noisy galvanic vestibular stimulation (nGVS) has been used to boost vestibular afferent information to the central nervous system. This has the potential to improve postural control for people for whom vestibular signals are weak, such as in bilateral vestibulopathy (BVP). The aim of this systematic review and meta-analysis is to investigate the evidence for nGVS as a modality to improve postural control in people with BVP. Methods A comprehensive systematic search was conducted of five databases up to July 2022 to find studies applying nGVS to people with BVP, with the aim of improving postural control. Two independent reviewers screened and identified eligible studies, completed a risk of bias evaluation (Cochrane) and extracted relevant data. The standardized mean difference (SMD) based on Hedges' g was calculated as a measure of effect size for the primary outcome measure that best identified postural control, and a forest plot generated. Results Seven studies met the eligibility criteria, with five being suitable for meta-analysis. Meta-analysis revealed a moderate effect in favor of nGVS improving postural control during standing and walking [pooled SMD = 0.47 95% CI (0.25, 0.7)]. nGVS-mediated improvements in postural control were most evident in observations of reduced sway velocity when standing on a firm surface with eyes closed, and in the reduced variability of gait parameters, particularly those measuring lateral stability. Conclusions Coincident nGVS in people with BVP improves postural control during standing and walking. This improvement appears to be context specific, in that vestibular augmentation is most effective in situations where visual inputs are limited, and where reliable context specific proprioceptive cues are available. Further research is warranted investigating additional circumstances in which nGVS improves postural control, including investigating the residual, and sustained effects of nGVS. Systematic review registration https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=342147, identifier: 342147.
Collapse
|
14
|
Thresholds for vestibular and cutaneous perception and oculomotor response induced by galvanic vestibular stimulation. Front Neurol 2022; 13:955088. [PMID: 36034303 PMCID: PMC9413160 DOI: 10.3389/fneur.2022.955088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Accepted: 07/18/2022] [Indexed: 12/04/2022] Open
Abstract
Objectives In this study, the specific threshold intensities and response characteristics of galvanic vestibular stimulation (GVS) on vestibular (conscious) and cutaneous (detrimental) perception as well as oculomotor nystagmus (reflex) were determined. Methods The threshold intensities for vestibular and cutaneous perception and oculomotor response induced by GVS were determined in 25 right-handed healthy subjects (32.6 ± 7.2 years of age; 56% female). The subjects were seated upright, and eye movements were recorded while a direct GVS current was applied with paradigms of cathode on the right and anode on the left (CRAL) and also cathode on the left and anode on the right (CLAR). Results Subjects experienced dizziness, sense of spinning, or fall tendency, which was more frequently directed to the cathode (76%) than the anode (24%, p < 0.001, chi-square one-variable test) at mean current greater than 0.98 ± 0.29 mA (mean vestibular threshold). The current also triggered a more frequent mild tingling sensation at the cathode (56%) than the anode (30%) or on both sides (14%; p = 0.001, chi-square one-variable test) when above the mean cutaneous threshold of 0.9 ± 0.29 mA. Above the mean oculomotor threshold of 1.61 ± 0.35 mA, combined horizontal and torsional nystagmus was more frequent toward the cathode (86%) than toward the anode (p < 0.001, chi-square one-variable test). The mean oculomotor threshold was significantly higher than both the vestibular (p < 0.001, Mann–Whitney U-test) and cutaneous (p < 0.001, Mann–Whitney U-test) thresholds, which were comparable (p = 0.317, Mann–Whitney U-test). There was no significant disparity in these specific thresholds between the two GVS paradigms. The vestibular threshold was significantly higher in males than in females [1 (0.5–1.25) mA vs. 0.75 (0.625–1.125) mA, Z = −2.241, p = 0.025, Mann–Whitney U-test]. However, the thresholds of cutaneous perception and oculomotor response did not differ by sex. Conclusion The findings indicate that thresholds for vestibular and somatosensory perception are lower than the oculomotor threshold. Therefore, a strategy to reduce GVS current intensity to the level of vestibular or somatosensory perception threshold could elicit beneficial vestibular effects while avoiding undesirable effects such as oculomotor consequences.
Collapse
|
15
|
Effects of Low-Intensity Vestibular Noise Stimulation on Postural Instability in Patients with Parkinson's Disease. JOURNAL OF PARKINSON'S DISEASE 2022; 12:1611-1618. [PMID: 35491798 DOI: 10.3233/jpd-213127] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
BACKGROUND Postural instability is a major disabling factor in patients with advanced Parkinson's disease (PD) and often resistant to treatment. Previous studies indicated that imbalance in PD may be reduced by low-intensity noisy galvanic vestibular stimulation (nGVS). OBJECTIVE To investigate the potential mode of action of this therapeutic effect. In particular, we examined whether nGVS-induced reductions of body sway in PD are compatible with stochastic resonance (SR), a mechanism by which weak sensory noise stimulation can paradoxically enhance sensory information transfer. METHODS Effects of nGVS of varying intensities (0-0.7 mA) on body sway were examined in 15 patients with PD standing with eye closed on a posturographic force plate. We assumed a bell-shaped response curve with maximal reductions of sway at intermediate nGVS intensities to be indicative of SR. An established SR-curve model was fitted on individual patient outcomes and three experienced human raters had to judge whether responses to nGVS were consistent with the exhibition of SR. RESULTS nGVS-induced reductions of body sway compatible with SR were found in 10 patients (67%) with optimal improvements of 23±13%. In 7 patients (47%), nGVS-induced sway reductions exceeded the minimally important clinical difference (optimal improvement: 30±10%), indicative of strong SR. This beneficial effect was more likely in patients with advanced PD (R = 0.45; p = 0.045). CONCLUSIONS At least half of the assessed patients showed robust improvements in postural balance compatible with SR when treated with low-intensity nGVS. In particular, patients with more advanced disease stages and imbalance may benefit from the non-invasive and well-tolerated treatment with nGVS.
Collapse
|
16
|
Different Types of Mastoid Process Vibrations Affect Dynamic Margin of Stability Differently. Front Hum Neurosci 2022; 16:896221. [PMID: 35832875 PMCID: PMC9271872 DOI: 10.3389/fnhum.2022.896221] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 05/30/2022] [Indexed: 12/03/2022] Open
Abstract
The vestibular system is critical for human locomotion. Any deteriorated vestibular system leads to gait instability. In the past decades, these alternations in gait patterns have been majorly measured by the spatial-temporal gait parameters and respective variabilities. However, measuring gait characteristics cannot capture the full aspect of motor controls. Thus, to further understand the effects of deteriorated vestibular system on gait performance, additional measurement needs to be taken into consideration. This study proposed using the margin of stability (MOS) to identify the patterns of dynamic control under different types of mastoid vibrations in walking. This study hypothesized that (1) using the MOS method could facilitate the understanding of another aspect of motor control induced by different types of mastoid vibrations, and (2) applying the mastoid vibrations could induce the asymmetric MOS. Twenty healthy young adults were recruited. Two electromechanical vibrotactile transducers were placed on the bilateral mastoid process to apply different types of vestibular vibrations (bilateral, unilateral, and no vibration). A motion capture system with eight cameras was used to measure the MOSap (margin of stability in the anterior-posterior direction), MOSml (margin of stability in the medial-lateral direction), and respective variabilities. The results were in line with the hypotheses that both bilateral and unilateral mastoid vibrations significantly increased MOSap (p = 0.036, p < 0.001), MOSml (p = 0.012, p < 0.001), and respective variabilities p = 0.001, p < 0.001; p = 0.001, p < 0.01 when compared to the no vibration condition. Also, significantly larger MOSml (p = 0.001), MOSml variability (p < 0.023), MOSap (p < 0.001), and MOSap variability (p = 0.002) were observed under the unilateral vibration condition than that observed under the bilateral vibration condition. The above-mentioned result found that different types of mastoid vibrations affected the MOS differently, suggesting different patterns of control mechanisms under different sensory-conflicted situations. Besides, a significant difference between the dominant and non-dominant legs was observed in MOSml. Moreover, applying the unilateral mastoid vibrations induced a greater symmetric index of MOSml, suggesting that more active control in balance was needed in the medial-lateral than in the anterior-posterior direction.
Collapse
|
17
|
Combining vestibular rehabilitation with noisy galvanic vestibular stimulation for treatment of bilateral vestibulopathy. J Neurol 2022; 269:5731-5737. [PMID: 35212789 PMCID: PMC9553809 DOI: 10.1007/s00415-022-11033-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 02/10/2022] [Accepted: 02/15/2022] [Indexed: 12/27/2022]
Abstract
Objective Noisy galvanic vestibular stimulation (nGVS) has been shown to partly restore vestibular function and to stabilize stance and gait in patients with incomplete bilateral vestibulopathy (BVP). Here, we examined potential synergistic effects of nGVS when combined with standardized vestibular rehabilitation training (VRT). Methods 23 patients with confirmed BVP received a 30-min vestibular rehabilitation training (VRT) program three times a week for 2 weeks. The intervention group (n = 12) was stimulated with nGVS (at individually determined optimal amplitudes) during training, whereas the control group (n = 11) received zero-amplitude nGVS (sham stimulation) during training. Outcome measurements assessed at baseline, after 2 weeks of training, and at 2-week follow-up included quantitative posturography, instrumented gait analysis, Timed Up and Go Test (TUG), Functional Gait Assessment (FGA), and clinical scores related to quality of life and balance confidence. Results After 2 weeks of VRT, all patients showed moderate improvement in balance. Irrespective of nGVS treatment, performance improved in the TUG (p < 0.013), and in the FGA (p < 0.040). Furthermore, base of support when walking with closed eyes was reduced after 2-week training (p < 0.003). Postural sway did not change. There was no difference between groups and thereby no evidence for an additional influence of nGVS on the VRT treatment effects. Conclusion nGVS does not induce synergistic treatment effects in combination with VRT in patients with BVP when applied during treatment sessions. Hence, rather than being applied in parallel, nGVS and VRT might be complementary therapeutic options with nGVS being used during postural activities in daily life, e.g., walking.
Collapse
|
18
|
Noisy Galvanic Vestibular Stimulation Combined With a Multisensory Balance Program in Older Adults With Moderate to High Fall Risk: Protocol for a Feasibility Study for a Randomized Controlled Trial. JMIR Res Protoc 2021; 10:e32085. [PMID: 34609323 PMCID: PMC8527374 DOI: 10.2196/32085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 08/10/2021] [Accepted: 08/10/2021] [Indexed: 11/19/2022] Open
Abstract
Background Reduced mobility and falls are common among older adults. Balance retraining programs are effective in reducing falls and in improving balance and mobility. Noisy galvanic vestibular stimulation is a low-level electrical stimulation used to reduce the threshold for the firing of vestibular neurons via a mechanism of stochastic resonance. Objective This study aims to determine the feasibility of using noisy galvanic vestibular stimulation to augment a balance training program for older adults at risk of falls. We hypothesize that noisy galvanic vestibular stimulation will enhance the effects of balance retraining in older adults at risk of falls Methods In this 3-armed randomized controlled trial, community dwelling older adults at risk of falling will be randomly assigned to a noisy galvanic vestibular stimulation plus balance program (noisy galvanic vestibular stimulation group), sham plus balance program (sham group), or a no treatment group (control). Participants will attend the exercise group twice a week for 8 weeks with assessment of balance and gait pretreatment, posttreatment, and at 3 months postintervention. Primary outcome measures include postural sway, measured by center of pressure velocity, area and root mean square, and gait parameters such as speed, step width, step variability, and double support time. Spatial memory will also be measured using the triangle completion task and the 4 Mountains Test. Results Recruitment began in November 2020. Data collection and analysis are expected to be completed by December 2022. Conclusions This study will evaluate the feasibility of using noisy galvanic vestibular stimulation alongside balance retraining in older adults at risk of falls and will inform the design of a fully powered randomized controlled trial. Trial Registration New Zealand Clinical Trials Registry (ACTRN12620001172998); https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=379944 International Registered Report Identifier (IRRID) DERR1-10.2196/32085
Collapse
|
19
|
Comparing activated brain regions between noisy and conventional galvanic vestibular stimulation using functional magnetic resonance imaging. Neuroreport 2021; 32:583-587. [PMID: 33850089 DOI: 10.1097/wnr.0000000000001629] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Galvanic vestibular stimulation (GVS) enhances vestibular sensory inputs in vestibular afferents. However, it is unclear whether noisy and conventional GVS activate different regions of the brain. The purpose of this study was to investigate the differences in activated brain regions between those two interventions using functional MRI (fMRI). METHODS Twenty-four healthy volunteers who met the inclusion/exclusion criteria were randomly assigned to the noisy GVS or conventional GVS groups. Brain activity was measured during stimulation and compared with that during resting fMRI. This study used a blocked design comprising four task-rest blocks, each consisting of a 30-s period of vestibular stimulation followed by a 30-s period of rest. We evaluated the differences in contrast images between the noisy and conventional GVS groups. RESULTS The noisy GVS group showed significantly increased activation in the vestibular system-related brain regions, including the insula and central operculum. The conventional GVS group showed significant activity in multisensory areas, including the supramarginal gyrus, central operculum and opercular part of the inferior frontal gyrus. Thus, the noisy GVS group showed significantly increased activity in the insula, putamen and central operculum compared with the conventional GVS group. CONCLUSIONS Noisy GVS could increase brain activity in the insular peripheral region compared to conventional GVS. Our results extend the literature about the importance of the stochastic resonance of noise addition for the vestibular system.
Collapse
|
20
|
Cortical Effects of Noisy Galvanic Vestibular Stimulation Using Functional Near-Infrared Spectroscopy. SENSORS 2021; 21:s21041476. [PMID: 33672519 PMCID: PMC7923808 DOI: 10.3390/s21041476] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2021] [Revised: 02/03/2021] [Accepted: 02/16/2021] [Indexed: 11/25/2022]
Abstract
Noisy galvanic vestibular stimulation (nGVS) can improve different motor, sensory, and cognitive behaviors. However, it is unclear how this stimulation affects brain activity to facilitate these improvements. Functional near-infrared spectroscopy (fNIRS) is inexpensive, portable, and less prone to motion artifacts than other neuroimaging technology. Thus, fNIRS has the potential to provide insight into how nGVS affects cortical activity during a variety of natural behaviors. Here we sought to: (1) determine if fNIRS can detect cortical changes in oxygenated (HbO) and deoxygenated (HbR) hemoglobin with application of subthreshold nGVS, and (2) determine how subthreshold nGVS affects this fNIRS-derived hemodynamic response. A total of twelve healthy participants received nGVS and sham stimulation during a seated, resting-state paradigm. To determine whether nGVS altered activity in select cortical regions of interest (BA40, BA39), we compared differences between nGVS and sham HbO and HbR concentrations. We found a greater HbR response during nGVS compared to sham stimulation in left BA40, a region previously associated with vestibular processing, and with all left hemisphere channels combined (p < 0.05). We did not detect differences in HbO responses for any region during nGVS (p > 0.05). Our results suggest that fNIRS may be suitable for understanding the cortical effects of nGVS.
Collapse
|
21
|
Effect of noisy galvanic vestibular stimulation on dynamic posture sway under visual deprivation in patients with bilateral vestibular hypofunction. Sci Rep 2021; 11:4229. [PMID: 33608568 PMCID: PMC7896086 DOI: 10.1038/s41598-021-83206-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Accepted: 01/27/2021] [Indexed: 01/31/2023] Open
Abstract
A single-blind study to investigate the effects of noisy galvanic vestibular stimulation (nGVS) in straight walking and 2 Hz head yaw walking for healthy and bilateral vestibular hypofunction (BVH) participants in light and dark conditions. The optimal stimulation intensity for each participant was determined by calculating standing stability on a force plate while randomly applying six graded nGVS intensities (0-1000 µA). The chest-pelvic (C/P) ratio and lateral deviation of the center of mass (COM) were measured by motion capture during straight and 2 Hz head yaw walking in light and dark conditions. Participants were blinded to nGVS served randomly and imperceivably. Ten BVH patients and 16 healthy participants completed all trials. In the light condition, the COM lateral deviation significantly decreased only in straight walking (p = 0.037) with nGVS for the BVH. In the dark condition, both healthy (p = 0.026) and BVH (p = 0.017) exhibited decreased lateral deviation during nGVS. The C/P ratio decreased significantly in BVH for 2 Hz head yaw walking with nGVS (p = 0.005) in light conditions. This study demonstrated that nGVS effectively reduced walking deviations, especially in visual deprived condition for the BVH. Applying nGVS with different head rotation frequencies and light exposure levels may accelerate the rehabilitation process for patients with BVH.Clinical Trial Registration This clinical trial was prospectively registered at www.clinicaltrials.gov with the Unique identifier: NCT03554941. Date of registration: (13/06/2018).
Collapse
|
22
|
The potential of noisy galvanic vestibular stimulation for optimizing and assisting human performance. Neuropsychologia 2021; 152:107751. [PMID: 33434573 DOI: 10.1016/j.neuropsychologia.2021.107751] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 01/07/2021] [Accepted: 01/08/2021] [Indexed: 12/17/2022]
Abstract
Noisy galvanic vestibular stimulation (nGVS) is an emerging non-invasive brain stimulation technique. It involves applying alternating currents of different frequencies and amplitudes presented in a random, or noisy, manner through electrodes on the mastoid bones behind the ears. Because it directly activates vestibular hair cells and afferents and has an indirect effect on a variety of brain regions, it has the potential to impact many different functions. The objective of this review is twofold: (1) to review how nGVS affects motor, sensory, and cognitive performance in healthy adults; and (2) to discuss potential clinical applications of nGVS. First, we introduce the technique. We then describe the regions receiving and processing vestibular information. Next, we discuss the effects of nGVS on motor, sensory, and cognitive function in healthy adults. Subsequently, we outline its potential clinical applications. Finally, we highlight other electrical stimulation technologies and discuss why nGVS offers an alternative or complementary approach. Overall, nGVS appears promising for optimizing human performance and as an assistive technology, though further research is required.
Collapse
|
23
|
Modification of Eye-Head Coordination With High Frequency Random Noise Stimulation. Front Hum Neurosci 2020; 14:592021. [PMID: 33328937 PMCID: PMC7718003 DOI: 10.3389/fnhum.2020.592021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Accepted: 10/15/2020] [Indexed: 11/26/2022] Open
Abstract
The vestibulo-ocular reflex (VOR) plays an important role in controlling the gaze at a visual target. Although patients with vestibular hypofunction aim to improve their VOR function, some retain dysfunction for a long time. Previous studies have explored the effects of direct current stimulation on vestibular function; however, the effects of random noise stimulation on eye–head coordination have not previously been tested. Therefore, we aimed to clarify the effects of high frequency noisy vestibular stimulation (HF-nVS) on eye–head coordination related to VOR function. Thirteen healthy young adult participants with no serious disease took part in our study. The current amplitude and density used were 0.4 mA and 0.2 mA/cm2, respectively, with a random noise frequency of 100–640 Hz. The electrodes were located on both mastoid processes. The stimulus duration and fade in/out duration were 600 and 10 s, respectively. Subjects oscillated their head horizontally, gazing at the fixation point, at 1 Hz (0.5 cycles/s) for 30 repetitions. The coordination of eye–head movements was measured by eye-tracking and a motion capture system. Peak-to-peak angles for eye and head movement and deviation of the visual line from the fixation target revealed no significant differences between HF-nVS and sham. The lag time between the eye and head movement with HF-nVS post-stimulation was significantly shorter than that of the sham. We found that HF-nVS can reduce the lag time between eye and head movement and improve coordination, contributing to a clear retinal image. This technique could be applied as a form of VOR training for patients with vestibular hypofunction.
Collapse
|
24
|
Effects of white noise in walking on walking time, state anxiety, and fear of falling among the elderly with mild dementia. Brain Behav 2020; 10:e01874. [PMID: 33034429 PMCID: PMC7749535 DOI: 10.1002/brb3.1874] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 08/07/2020] [Accepted: 09/17/2020] [Indexed: 11/30/2022] Open
Abstract
OBJECTIVE This study aimed to analyze the effects of white noise in walking on the walking time, state anxiety, and fear of falling of the elderly with mild dementia. METHODS Subjects were 32 elderlies with mild dementia, and they divided into experimental group and control group, respectively. In the experimental group, walking program with white noise was applied 3 times a week for 4 weeks. White noise was provided by white noise generator in walking program. In the control group, walking program only was applied. To measure the effect of white noise in walking among the subjects, the walking time, state anxiety, and fear of falling were measured. Walking time was measured by Timed Up and Go test. State anxiety related in walking was measured by Korean version of State-Trait Anxiety Inventory. Fear of falling was used by Korean Falls Efficacy Scale. RESULTS The results of walking time showed the increase in both groups, but the statistically significant difference was not shown. However, the results of state anxiety and fear of falling showed decrease and the statistically significant difference was shown (p < .01). In comparative analysis, the statistically significant difference in the results of gate velocity between groups was not shown. However, in the results of state anxiety and fear of falling the statistically significant difference between groups was shown (p < .01). CONCLUSIONS White noise in walking should be induced positively to decrease the state anxiety and fear of falling in walking among elderly with mild dementia. Thus, in their environment, to decrease of state anxiety and fear of falling occurring in walking, the application of white noise in walking situation should be considered to apply for them.
Collapse
|
25
|
Head orientation and gait stability in young adults, dancers and older adults. Gait Posture 2020; 80:68-73. [PMID: 32492622 DOI: 10.1016/j.gaitpost.2020.05.035] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Revised: 04/07/2020] [Accepted: 05/20/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND Control of body orientation requires head motion detection by the vestibular system and small changes with respect to the gravitational acceleration vector could cause destabilization. RESEARCH QUESTION We aimed to compare the effects of different head orientations on gait stability in young adults, dancers and older adults. METHODS Three groups of 10 subjects were evaluated, the first composed of young adults (aged 18-30 years), the second composed of young healthy dancers under high performance dance training (aged 18-30 years), and the third group composed of community-dwelling older adults (aged 65-80 years). Participants walked on a treadmill at their preferred speed in four distinct head orientation conditions for four minutes each: control (neutral orientation); dynamic yaw (following a target over 45° bilaterally); up (15° neck extension), and down (40° neck flexion). Foot and trunk kinematic data were acquired using a 3D motion capture system and the gait pattern was assessed by basic gait parameters (step length, stride width and corresponding variability) and gait stability (local divergence exponents and margins of stability). Main effects of conditions and groups, as well as their interaction effects, were evaluated by repeated-measures analysis of variance. RESULTS Interactions of group and head orientation were found for both step length and stride width variability; main effects of head orientation were found for all evaluated parameters and main effects of group were found for step length and its variability and local divergence exponents in all directions. SIGNIFICANCE As expected, the older adults group showed less stable gait (higher local divergence exponent), the shortest step length and greater step length variability. However, contrary to expectation, the dancers were not more stable. The yaw condition was the most challenging for all groups and the down condition seemed to be least challenging.
Collapse
|
26
|
Impact of galvanic vestibular stimulation-induced stochastic resonance on the output of the vestibular system: A systematic review. Brain Stimul 2020; 13:533-535. [DOI: 10.1016/j.brs.2020.01.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 01/07/2020] [Accepted: 01/08/2020] [Indexed: 11/21/2022] Open
|
27
|
Effects of perceptible and imperceptible galvanic vestibular stimulation on the postural control of patients with bilateral vestibulopathy. J Neurol 2020; 267:2383-2397. [DOI: 10.1007/s00415-020-09852-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 04/17/2020] [Accepted: 04/18/2020] [Indexed: 01/01/2023]
|
28
|
Subthreshold stochastic vestibular stimulation affects balance-challenged standing and walking. PLoS One 2020; 15:e0231334. [PMID: 32275736 PMCID: PMC7147773 DOI: 10.1371/journal.pone.0231334] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Accepted: 03/20/2020] [Indexed: 11/19/2022] Open
Abstract
Subthreshold stochastic vestibular stimulation (SVS) is thought to enhance vestibular sensitivity and improve balance. However, it is unclear how SVS affects standing and walking when balance is challenged, particularly when the eyes are open. It is also unclear how different methods to determine stimulation intensity influence the effects. We aimed to determine (1) whether SVS affects stability when balance is challenged during eyes-open standing and overground walking tasks, and (2) how the effects differ based on whether optimal stimulation amplitude is derived from sinusoidal or cutaneous threshold techniques. Thirteen healthy adults performed balance-unchallenged and balance-challenged standing and walking tasks with SVS (0–30 Hz zero-mean, white noise electrical stimulus) or sham stimulation. For the balance-challenged condition, participants had inflatable rubber hemispheres attached to the bottom of their shoes to reduce the control provided by moving the center of pressure under their base of support. In different blocks of trials, we set SVS intensity to either 50% of participants’ sinusoidal (motion) threshold or 80% of participants’ cutaneous threshold. SVS reduced medial-lateral trunk velocity root mean square in the balance-challenged (p < 0.05) but not in the balance-unchallenged condition during standing. Regardless of condition, SVS decreased step-width variability and marginally increased gait speed when walking with the eyes open (p < 0.05). SVS intensity had minimal effect on the standing and walking measures. Taken together, our results provide insight into the effectiveness of SVS at improving balance-challenged, eyes-open standing and walking performance in healthy adults.
Collapse
|
29
|
Noisy galvanic vestibular stimulation has a greater ameliorating effect on posture in unstable subjects: a feasibility study. Sci Rep 2019; 9:17189. [PMID: 31748596 PMCID: PMC6868214 DOI: 10.1038/s41598-019-53834-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Accepted: 11/04/2019] [Indexed: 01/28/2023] Open
Abstract
Ameliorating effect of noisy galvanic vestibular stimulation (nGVS) on posture varies among subjects. In this feasibility study, we investigated the association between original postural instability and the ameliorating effect of nGVS on posture. Data were collected in a previously published study. Thirty healthy elderly were recruited. Two nGVS sessions (30 min or 3 h) were performed in a randomised order. The optimal intensity of nGVS, the most effective intensity for improving posture, was determined before each session. Posture was measured for 30 s during and after nGVS in the eyes-closed/foam rubber condition. The velocity, envelopment area, and root mean square of the centre of pressure movement without nGVS were significantly larger in the group with an optimal intensity than those in the group without an optimal intensity. There was a significant positive correlation between these values and the long-term ameliorating effects. The ratio of the values in the eyes-closed/foam rubber condition to those in the eyes-open condition was significantly larger in the group with an optimal intensity, and had a significant correlation with the long-term ameliorating effects. The ameliorating effects are greater in subjects who were originally unstable and in those whose postural stability was relatively independent of vestibular input.
Collapse
|
30
|
Effects of Noisy Galvanic Vestibular Stimulation During a Bimanual Tracking Robotic Task. Front Neurosci 2019; 13:1132. [PMID: 31749673 PMCID: PMC6843009 DOI: 10.3389/fnins.2019.01132] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Accepted: 10/07/2019] [Indexed: 12/21/2022] Open
Abstract
Background Noisy galvanic vestibular stimulation (nGVS) has been shown to improve motor performance in people with and without disabilities. Previous investigations on the use of nGVS to improve upper-limb motor performance have focused on unimanual fine motor movements, nevertheless, bimanual gross movements are also essential for conducting activities of daily living and can be affected as a result of cerebral dysfunction. Consequently, in this study we investigated the effects of nGVS on bimanual gross motor performance. Methods Twelve healthy participants completed a visuomotor task in which they performed bimanual upper-limb movements using two robots. During the task, participants tracked a target that oscillated following a sinusoidal amplitude-modulated trajectory. In half of the trials, participants received subthreshold nGVS, in the other half, they received sham stimulation. Primary outcome measure: percent improvement in root mean square error (RMSE) between the target’s and cursors’ trajectories. Secondary outcome measures: percent improvement in lag between the cursors and target; and percent improvement in RMSE between the cursors’ trajectories. A post-test questionnaire was administered to evaluate the experience of participants. Results Tracking error was not affected by nGVS: left −2.6(5.5)%, p = 0.128; right −0.9(6.2)%, p = 0.639; nor was bimanual coordination −1.5(9.6)%, p = 0.590. When comparing if one hand was affected more than the other, we did not find a statistically significant difference (−1.7(3.3)%, p = 0.098). Similar results were found for the lag. Questionnaire results indicated that the robotic devices did not limit participants’ movements, did not make participants feel unsafe, nor were they difficult to control. Furthermore, participants did not feel unsafe with the nGVS device, nor did they report any discomfort due to nGVS. Conclusion Results suggest that nGVS applied to people without disabilities do not affect bimanual gross motor performance. However, as this was the first study to investigate such effects, stimulation parameters were based on previous unimanual fine motor studies. Future studies should investigate optimal stimulation parameters for improving upper-limb gross motor performance. Overall, participants felt safe using the robotic devices and receiving the noisy electrical stimulation. As such, a similar setup could potentially be employed for subsequent studies investigating the relation between upper-limb performance and nGVS.
Collapse
|
31
|
Electrical Vestibular Stimulation in Humans: A Narrative Review. Audiol Neurootol 2019; 25:6-24. [PMID: 31533097 DOI: 10.1159/000502407] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Accepted: 07/29/2019] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND In patients with bilateral vestibulopathy, the regular treatment options, such as medication, surgery, and/or vestibular rehabilitation, do not always suffice. Therefore, the focus in this field of vestibular research shifted to electrical vestibular stimulation (EVS) and the development of a system capable of artificially restoring the vestibular function. Key Message: Currently, three approaches are being investigated: vestibular co-stimulation with a cochlear implant (CI), EVS with a vestibular implant (VI), and galvanic vestibular stimulation (GVS). All three applications show promising results but due to conceptual differences and the experimental state, a consensus on which application is the most ideal for which type of patient is still missing. SUMMARY Vestibular co-stimulation with a CI is based on "spread of excitation," which is a phenomenon that occurs when the currents from the CI spread to the surrounding structures and stimulate them. It has been shown that CI activation can indeed result in stimulation of the vestibular structures. Therefore, the question was raised whether vestibular co-stimulation can be functionally used in patients with bilateral vestibulopathy. A more direct vestibular stimulation method can be accomplished by implantation and activation of a VI. The concept of the VI is based on the technology and principles of the CI. Different VI prototypes are currently being evaluated regarding feasibility and functionality. So far, all of them were capable of activating different types of vestibular reflexes. A third stimulation method is GVS, which requires the use of surface electrodes instead of an implanted electrode array. However, as the currents are sent through the skull from one mastoid to the other, GVS is rather unspecific. It should be mentioned though, that the reported spread of excitation in both CI and VI use also seems to induce a more unspecific stimulation. Although all three applications of EVS were shown to be effective, it has yet to be defined which option is more desirable based on applicability and efficiency. It is possible and even likely that there is a place for all three approaches, given the diversity of the patient population who serves to gain from such technologies.
Collapse
|
32
|
Abstract
Purpose of review Bilateral vestibular deficits exist and their prevalence is more important than believed by the medical community. Their severe impact has inspired several teams to develop technical solutions in an attempt to rehabilitate patients. A particularly promising pathway is the vestibular implant. This article describes the main milestones in this field, mainly focusing on work conducted in human patients. Recent findings There have been substantial research efforts, first in animals and more recently in humans, toward the development of vestibular implants. Humans have demonstrated surprising adaptation capabilities to the artificial vestibular signal. Today, the possibility of restoring vestibular reflexes, particularly the vestibulo-ocular reflex, and even achieving useful function in close-to-reality tasks (i.e. improving visual abilities while walking) have been demonstrated in humans. Summary The vestibular implant opens new perspectives, not only as an effective therapeutic tool, but also pushes us to go beyond current knowledge and well-established clinical concepts.
Collapse
|
33
|
Increased brain responsivity to galvanic vestibular stimulation in bilateral vestibular failure. NEUROIMAGE-CLINICAL 2019; 24:101942. [PMID: 31382239 PMCID: PMC6690736 DOI: 10.1016/j.nicl.2019.101942] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2018] [Revised: 05/31/2019] [Accepted: 07/17/2019] [Indexed: 01/30/2023]
Abstract
In this event-related functional magnetic resonance imaging (fMRI) study we investigated how the brain of patients with bilateral vestibular failure (BVF) responds to vestibular stimuli. We used imperceptible noisy galvanic vestibular stimulation (GVS) and perceptible bi-mastoidal GVS intensities and related the corresponding brain activity to the evoked motion perception. In contrast to caloric irrigation, GVS stimulates the vestibular organ at its potentially intact afferent nerve site. Motion perception thresholds and cortical responses were compared between 26 BVF patients to 27 age-matched healthy control participants. To identify the specificity of vestibular cortical responses we used a parametric design with different stimulus intensities (noisy imperceptible, low perceptible, high perceptible) allowing region-specific stimulus response functions. In a 2 × 3 flexible factorial design all GVS-related brain activities were contrasted with a sham condition that did not evoke perceived motion. Patients had a higher motion perception threshold and rated the vestibular stimuli higher than the healthy participants. There was a stimulus intensity related and region-specific increase of activity with steep stimulus response functions in parietal operculum (e.g. OP2), insula, superior temporal gyrus, early visual cortices (V3) and cerebellum while activity in the hippocampus and intraparietal sulcus did not correlate with vestibular stimulus intensity. Using whole brain analysis, group comparisons revealed increased brain activity in early visual cortices (V3) and superior temporal gyrus of patients but there was no significant interaction, i.e. stimulus-response function in these regions were still similar in both groups. Brain activity in these regions during (high)GVS increased with higher dizziness-related handicap scores but was not related to the degree of vestibular impairment or disease duration. nGVS did not evoke cortical responses in any group. Our data indicate that perceptible GVS-related cortical responsivity is not diminished but increased in multisensory (visual-vestibular) cortical regions despite bilateral failure of the peripheral vestibular organ. The increased activity in early visual cortices (V3) and superior temporal gyrus of BVF patients has several potential implications: (i) their cortical reciprocal inhibitory visuo-vestibular interaction is dysfunctional, (ii) it may contribute to the visual dependency of BVF patients, and (iii) it needs to be considered when BVF patients receive peripheral vestibular stimulation devices, e.g. vestibular implants or portable GVS devices. Imperceptible nGVS did not elicit cortical brain responses making it unlikely that the reported balance improvement of BVF by nGVS is mediated by cortical mechanisms. Responsivity to galvanic vestibular stimuli is increased in the visual and superior temporal Cortex of patients with bilateral vestibulopathy. Group differences correlated with clinical scores of disability. Dysfunctional visual-vestibular interaction is proposed.
Collapse
|
34
|
Noisy galvanic vestibular stimulation modulates spatial memory in young healthy adults. Sci Rep 2019; 9:9310. [PMID: 31249334 PMCID: PMC6597709 DOI: 10.1038/s41598-019-45757-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Accepted: 06/14/2019] [Indexed: 02/07/2023] Open
Abstract
Hippocampal and striatal circuits play important roles in spatial navigation. These regions integrate environmental information and receive intrinsic afferent inputs from the vestibular system. Past research indicates that galvanic vestibular stimulation (GVS) is a non-invasive technique that modulates hippocampal and striatal activities. There are also evidences for enhanced motor and cognitive functions through GVS. This study extends previous research to investigate whether noisy GVS may improve hippocampal- and striatal-associated aspects of spatial navigation performance. Using a virtual navigation task, we examined effects of noisy GVS on spatial learning and memory. To probe the participants’ sensitivity to hippocampal- or striatal-associated spatial information, we either enlarged the virtual environment’s boundary or replaced an intra-environmental location cue, respectively. Noisy GVS or sham stimulation was applied online during the learning phase in a within-subject crossover design. The results showed that noisy GVS enhanced spatial learning and the sensitivity foremost to hippocampal-dependent spatial information both in males and females. Individual differences in spatial working memory capacity moderated the effects of GVS, with individuals with lower capacity benefitting more from the stimulation. Furthermore, sex-related differences in GVS effects on the two forms of spatial representations may reflect differences between males and females in preferred spatial strategies.
Collapse
|
35
|
Galvanic vestibular stimulation: from basic concepts to clinical applications. J Neurophysiol 2019; 121:2237-2255. [DOI: 10.1152/jn.00035.2019] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Galvanic vestibular stimulation (GVS) plays an important role in the quest to understand sensory signal processing in the vestibular system under normal and pathological conditions. It has become a highly relevant tool to probe neuronal computations and to assist in the differentiation and treatment of vestibular syndromes. Following its accidental discovery, GVS became a diagnostic tool that generates eye movements in the absence of head/body motion. With the possibility to record extracellular and intracellular spikes, GVS became an indispensable method to activate or block the discharge in vestibular nerve fibers by cathodal and anodal currents, respectively. Bernie Cohen, in his attempt to decipher vestibular signal processing, has used this method in a number of hallmark studies that have added to our present knowledge, such as the link between selective electrical stimulation of semicircular canal nerves and the generation of directionally corresponding eye movements. His achievements paved the way for other major milestones including the differential recruitment order of vestibular fibers for cathodal and anodal currents, pronounced discharge adaptation of irregularly firing afferents, potential activation of hair cells, and fiber type-specific activation of central circuits. Previous disputes about the structural substrate for GVS are resolved by integrating knowledge of ion channel-related response dynamics of afferents, fiber type-specific innervation patterns, and central convergence and integration of semicircular canal and otolith signals. On the basis of solid knowledge of the methodology, specific waveforms of GVS are currently used in clinical diagnosis and patient treatment, such as vestibular implants and noisy galvanic stimulation.
Collapse
|
36
|
Investigation on the effect of noisy galvanic vestibular stimulation on fine motor skills during a visuomotor task in healthy participants. PLoS One 2019; 14:e0216214. [PMID: 31048906 PMCID: PMC6497271 DOI: 10.1371/journal.pone.0216214] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Accepted: 04/16/2019] [Indexed: 11/24/2022] Open
Abstract
Noisy galvanic vestibular stimulation (nGVS) has been shown to improve dynamic walking stability, affect postural responses, enhance balance in healthy subjects, and influence motor performance in individuals with Parkinson’s disease. Although the studies to fully characterize the effect of nGVS are still ongoing, stochastic resonance theory which states that the addition of noisy signal may enhance a weak sensory input signals transmission in a non-linear system may provide a possible explanation for the observed positive effects of nGVS. This study explores the effect of nGVS on fine tracking behavior in healthy subjects. Ten healthy participants performed a computer-based visuomotor task by controlling an object with a joystick to follow an amplitude-modulated signal path while simultaneously receiving a sham or pink noise nGVS. The stimulation was generated to have a zero-mean, linearly detrended 1/f-type power spectrum, Gaussian distribution within 0.1–10 Hz range, and a standard deviation (SD) set to 90% based on each participant’s cutaneous threshold value. Results show that simultaneous nGVS delivery statistically improved the tracking performance with a decreased root-mean-squared error of 5.71±6.20% (mean±SD), a decreased time delay of 11.88±9.66% (mean±SD), and an increased signal-to-noise ratio of 2.93% (median, interquartile range (IQR) 3.31%). This study showed evidence that nGVS may be beneficial in improving sensorimotor performance during a fine motor tracking task requiring fine wrist movement in healthy subjects. Further research with a more comprehensive subset of tasks is required to fully characterize the effects of nGVS on fine motor skills.
Collapse
|
37
|
Postural control during galvanic vestibular stimulation in patients with persistent perceptual-postural dizziness. J Neurol 2019; 266:1236-1249. [PMID: 30809703 DOI: 10.1007/s00415-019-09255-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Revised: 02/15/2019] [Accepted: 02/18/2019] [Indexed: 12/15/2022]
Abstract
Over the past years galvanic vestibular stimulation (GVS) has been increasingly applied to stimulate the vestibular system in health and disease, but not in patients with persistent postural-perceptual dizziness (PPPD) yet. We functionally tested motion perception thresholds and postural responses to imperceptible noisy (nGVS) and perceptible bimastoidal GVS intensities in patients with PPPD with normal vestibulo-ocular reflexes. We hypothesized that GVS destabilizes PPPD patients under simple postural conditions stronger compared to healthy controls. They were compared to healthy subjects under several conditions each with the eyes open and closed: baseline with firm platform support, standing on foam and cognitive demand (count backward). Low and high GVS intensities (range 0.8-2.8 mA) were applied according to the individual thresholds and compared with no GVS. PPPD patients showed a reduced perception threshold to GVS compared to healthy control subjects. Median postural sway speed increased with stimulus intensity and on eye closure, but there was no group difference, irrespective of the experimental condition. Romberg's ratio was consistently lower during nGVS than in all other conditions. Group-related dissociable effects were found with the eyes closed in (i) the baseline condition in which high GVS elicited higher postural sway of PPPD patients and (ii) in the foam condition, with better postural stability of PPPD patients during perceptible GVS. Group and condition differences of postural control were neither related to anxiety nor depression scores. GVS may be helpful to identify thresholds of vestibular perception and to modulate vestibulo-spinal reflexes in PPPD, with dissociable effects with respect to perceptible and imperceptible stimuli. The sway increase in the baseline of PPPD may be related to an earlier transition from open- to closed-loop mode of postural control. In contrast, the smaller sway of PPPD in the foam condition under visual deprivation is in line with the known balance improvement under more demanding postural challenges in PPPD. It is associated with a prolonged transition from open- to closed-loop postural feedback control. It could also reflect a shift of intersensory weighting with a smaller dependence on proprioceptive feedback control in PPPD patients under complex tasks. In summary, GVS discloses differences between simple and complex balance tasks in PPPD.
Collapse
|
38
|
Noisy Galvanic Vestibular Stimulation Primarily Affects Otolith-Mediated Motion Perception. Neuroscience 2019; 399:161-166. [DOI: 10.1016/j.neuroscience.2018.12.031] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2018] [Revised: 12/17/2018] [Accepted: 12/18/2018] [Indexed: 10/27/2022]
|
39
|
Abstract
Multisensory integration is essential for maintenance of motor and cognitive abilities, thereby ensuring normal function and personal autonomy. Balance control is challenged during senescence or in motor disorders, leading to potential falls. Increased uncertainty in sensory signals is caused by a number of factors including noise, defined as a random and persistent disturbance that reduces the clarity of information. Counter-intuitively, noise can be beneficial in some conditions. Stochastic resonance is a mechanism whereby a particular level of noise actually enhances the response of non-linear systems to weak sensory signals. Here we review the effects of stochastic resonance on sensory modalities and systems directly involved in balance control. We highlight its potential for improving sensorimotor performance as well as cognitive and autonomic functions. These promising results demonstrate that stochastic resonance represents a flexible and non-invasive technique that can be applied to different modalities simultaneously. Finally we point out its benefits for a variety of scenarios including in ambulant elderly, skilled movements, sports and to patients with sensorimotor or autonomic dysfunctions.
Collapse
|
40
|
You are better off running than walking revisited: Does an acute vestibular imbalance affect muscle synergies? Hum Mov Sci 2018; 62:150-160. [PMID: 30384183 DOI: 10.1016/j.humov.2018.10.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Revised: 08/31/2018] [Accepted: 10/21/2018] [Indexed: 12/30/2022]
Abstract
It has been suggested that vestibular cues are inhibited for the benefit of spinal locomotor centres in parallel with the increase in locomotion speed. This study aimed at quantifying the influence of a transient vestibular tone imbalance (TVTI) on gait kinematics, muscle activity and muscle synergies during walking and running. Twelve participants walk or run at a self-selected speed with or without TVTI, which was generated by 10 body rotations just prior the locomotion task. Three-dimensional lower-limb kinematic was recorded simultaneously with the surface electromyographic (EMG) activity of 8 muscles to extract muscle synergies via non-negative matrix factorization. Under TVTI, there was an increased gait deviation in walking compared to running (22.8 ± 8.4° and 8.5 ± 3.6°, respectively; p < 0.01), while the number (n = 4) and the composition of the muscle synergies did not differ across conditions (p = 0.78). A higher increase (p < 0.05) in EMG activity due to TVTI was found during walking compared to running, especially during stance. These findings confirmed that the central nervous system inhibited misleading vestibular signals according to the increase in locomotion speed for the benefit of spinal mechanisms, expressed by the muscle synergies.
Collapse
|
41
|
Noisy Galvanic Vestibular Stimulation Sustainably Improves Posture in Bilateral Vestibulopathy. Front Neurol 2018; 9:900. [PMID: 30405522 PMCID: PMC6204397 DOI: 10.3389/fneur.2018.00900] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Accepted: 10/03/2018] [Indexed: 11/26/2022] Open
Abstract
Patients with bilateral vestibulopathy (BV) suffer from persistent postural imbalance, leading to a marked decrease in quality of life and a higher risk of falls. However, so far, the effective treatments for BV are very limited. We examined whether long-term noisy galvanic vestibular stimulation (nGVS) keeps improving body balance after the cessation of the stimulus in BV patients. Thirteen BV patients received nGVS for 30 min with a lower intensity than the intensity at which they feel any cutaneous sensations, and their postural movement was monitored for 6 h after the stimuli. The same session was repeated at 14-day intervals. Stance tasks on two legs were performed with eyes closed. The velocity of the center of pressure (COP) movement, the area enclosed by the COP movement, and the root mean square of the displacement of the COP were measured. The power spectrum of the COP movement was assessed. Subjective improvement of body balance was graded as worsened (−2), slightly worsened (−1), unchanged (0), slightly improved (+1) and improved (+2) in comparison with that without nGVS. In each session, the velocity of the COP movement was significantly improved for 6 h after the stimulus had ceased (P < 0.01). Concomitantly, the mean frequency of the COP power spectrum was significantly reduced in the anterior-posterior axis (P < 0.05). Subjective symptoms of imbalance were improved during the post-stimulation effect (P < 0.05). nGVS leads to an improvement in body balance that lasts for several hours after the end of the stimulus in BV patients with a reduction in the high-frequency components of their postural movement. This trial was registered with the University Hospital Medical Information Network (UMIN) Clinical Trials Registry (UMINCTR: UMIN000028054).
Collapse
|
42
|
Effects of Galvanic Vestibular Stimulation on Upper and Lower Extremities Motor Symptoms in Parkinson's Disease. Front Neurosci 2018; 12:633. [PMID: 30254564 PMCID: PMC6141687 DOI: 10.3389/fnins.2018.00633] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2018] [Accepted: 08/23/2018] [Indexed: 11/17/2022] Open
Abstract
As a neurodegenerative movement disorder, Parkinson’s disease (PD) is commonly characterized by motor symptoms such as resting tremor, rigidity, bradykinesia, and balance and postural impairments. While the main cause of PD is still not clear, it is shown that the basal ganglia loop, which has a role in adjusting a planned movement execution through fine motor control, is altered during this disease and contributes toward the manifested motor symptoms. Galvanic vestibular stimulation (GVS) is a non-invasive technique to influence the vestibular system and stimulate the motor system. This study explores how the motor symptoms of upper and lower extremities in PD are instantly affected by vestibular stimulation. In this regard, direct current GVS was applied to 11 individuals with PD on medication while they were performing two sets of experiments: (1) Instrumented Timed Up and Go (iTUG) test and (2) finger tapping task. The performance of participants was recorded with accelerometers and cameras for offline processing of data. Several outcome measures including coefficient of variation of the step duration, gait phase, phase coordination index, tapping score, and the number and duration of manual motor blocks (MMBs) were considered for objective quantifying of performance. Results showed that almost all of considered outcome measures were improved with the application of GVS and that the improvement in the coefficient of variation of the step duration, the tapping score, and the number of MMBs was statistically significant (p-value < 0.05). The results of this study suggest that GVS can be used to alleviate some of the common motor symptoms of PD. Further research is required to fully characterize the effects of GVS and determine its efficacy in the long term.
Collapse
|
43
|
Effect of vibration during visual-inertial integration on human heading perception during eccentric gaze. PLoS One 2018; 13:e0199097. [PMID: 29902253 PMCID: PMC6002115 DOI: 10.1371/journal.pone.0199097] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2017] [Accepted: 05/31/2018] [Indexed: 11/21/2022] Open
Abstract
Heading direction is determined from visual and inertial cues. Visual headings use retinal coordinates while inertial headings use body coordinates. Thus during eccentric gaze the same heading may be perceived differently by visual and inertial modalities. Stimulus weights depend on the relative reliability of these stimuli, but previous work suggests that the inertial heading may be given more weight than predicted. These experiments only varied the visual stimulus reliability, and it is unclear what occurs with variation in inertial reliability. Five human subjects completed a heading discrimination task using 2s of translation with a peak velocity of 16cm/s. Eye position was ±25° left/right with visual, inertial, or combined motion. The visual motion coherence was 50%. Inertial stimuli included 6 Hz vertical vibration with 0, 0.10, 0.15, or 0.20cm amplitude. Subjects reported perceived heading relative to the midline. With an inertial heading, perception was biased 3.6° towards the gaze direction. Visual headings biased perception 9.6° opposite gaze. The inertial threshold without vibration was 4.8° which increased significantly to 8.8° with vibration but the amplitude of vibration did not influence reliability. With visual-inertial headings, empirical stimulus weights were calculated from the bias and compared with the optimal weight calculated from the threshold. In 2 subjects empirical weights were near optimal while in the remaining 3 subjects the inertial stimuli were weighted greater than optimal predictions. On average the inertial stimulus was weighted greater than predicted. These results indicate multisensory integration may not be a function of stimulus reliability when inertial stimulus reliability is varied.
Collapse
|
44
|
Efficacy of Stochastic Vestibular Stimulation to Improve Locomotor Performance During Adaptation to Visuomotor and Somatosensory Distortion. Front Physiol 2018; 9:301. [PMID: 29651250 PMCID: PMC5885191 DOI: 10.3389/fphys.2018.00301] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Accepted: 03/13/2018] [Indexed: 11/13/2022] Open
Abstract
Astronauts exposed to microgravity face sensorimotor challenges affecting balance control when readapting to Earth's gravity upon return from spaceflight. Small amounts of electrical noise applied to the vestibular system have been shown to improve balance control during standing and walking under discordant sensory conditions in healthy subjects, likely by enhancing information transfer through the phenomenon of stochastic resonance. The purpose of this study was to test the hypothesis that imperceptible levels of stochastic vestibular stimulation (SVS) could improve short-term adaptation to a locomotor task in a novel sensory discordant environment. Healthy subjects (14 males, 10 females, age = 28.7 ± 5.3 years, height = 167.2 ± 9.6 cm, weight = 71.0 ± 12.8 kg) were tested for perceptual thresholds to sinusoidal currents applied across the mastoids. Subjects were then randomly and blindly assigned to an SVS group receiving a 0–30 Hz Gaussian white noise electrical stimulus at 50% of their perceptual threshold (stim) or a control group receiving zero stimulation during Functional Mobility Tests (FMTs), nine trials of which were done under conditions of visual discordance (wearing up/down vision reversing goggles). Time to complete the course (TCC) was used to test the effect of SVS between the two groups across the trials. Adaptation rates from the normalized TCCs were also compared utilizing exponent values of power fit trendline equations. A one-tailed independent-samples t-test indicated these adaptation rates were significantly faster in the stim group (n = 12) than the control (n = 12) group [t(16.18) = 2.00, p = 0.031]. When a secondary analysis was performed comparing “responders” (subjects who showed faster adaptation rates) of the stim (n = 7) group to the control group (n = 12), independent-samples t-tests revealed significantly faster trial times for the last five trials with goggles in the stim group “responders” than the controls. The data suggests that SVS may be capable of improving short-term adaptation to a locomotion task done under sensory discordance in a group of responsive subjects.
Collapse
|
45
|
Noisy vestibular stimulation increases gait speed in normals and in bilateral vestibulopathy. Brain Stimul 2018; 11:709-715. [PMID: 29563049 DOI: 10.1016/j.brs.2018.03.005] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Revised: 03/06/2018] [Accepted: 03/07/2018] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Galvanic vestibular stimulation delivered as zero-mean current noise (noisy GVS) has been shown to improve static and dynamic postural stability probably by enhancing vestibular information. OBJECTIVE /Hypothesis: To examine the effect of an imperceptible level of noisy GVS on dynamic locomotion in normal subjects as well as in patients with bilateral vestibulopathy. METHODS Walking performance of 19 healthy subjects and 12 patients with bilateral vestibulopathy at their preferred speed was examined during application of noisy GVS with an amplitude ranging from 0 to 1000 μA. The gait velocity, stride length and stride time were analyzed. RESULTS Noisy GVS had significant effects on gait velocity, stride length and stride time in healthy subjects as well as in patients with bilateral vestibulopathy (p < 0.05). The optimal amplitude of noisy GVS improved gait velocity by 10.9 ± 1.2%, stride length by 5.7 ± 1.2% and stride time by 4.6 ± 7% (p < 0.0001) compared to the control session in healthy subjects. The optimal stimulus improved gait velocity by 12.8 ± 1.3%, stride length by 8.3 ± 1.1% and stride time by 3.7 ± 7% (p < 0.0001) in patients with bilateral vestibulopathy. The improved values of these parameters of locomotion by noisy GVS in the patients were not significantly different from those in healthy subjects in the control condition (p > 0.4). CONCLUSION Noisy GVS is effective in improving gait performance in healthy subjects as well as in patients with bilateral vestibulopathy.
Collapse
|
46
|
Noisy vestibular stimulation improves vestibulospinal function in patients with bilateral vestibulopathy. J Neurol 2018; 265:57-62. [DOI: 10.1007/s00415-018-8814-y] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Revised: 02/25/2018] [Accepted: 02/26/2018] [Indexed: 10/17/2022]
|
47
|
Stochastic resonance in the human vestibular system – Noise-induced facilitation of vestibulospinal reflexes. Brain Stimul 2018; 11:261-263. [DOI: 10.1016/j.brs.2017.10.016] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Accepted: 10/21/2017] [Indexed: 11/26/2022] Open
|
48
|
Noisy Galvanic Stimulation Improves Roll-Tilt Vestibular Perception in Healthy Subjects. Front Neurol 2018; 9:83. [PMID: 29545766 PMCID: PMC5837962 DOI: 10.3389/fneur.2018.00083] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Accepted: 02/06/2018] [Indexed: 11/13/2022] Open
Abstract
It has recently been demonstrated that noisy galvanic vestibular stimulation (nGVS) delivered as imperceptible white noise can improve balance control via the induction of stochastic resonance. However, it is unclear whether these balance improvements are accompanied by simultaneous enhancement to vestibular motion perception. In this study, 15 healthy subjects performed 8 quiet-stance tasks on foam with eyes closed at 8 different nGVS amplitudes ranging from 0 mA (baseline) to 0.5 mA. The nGVS amplitude that improved balance performance most compared to baseline was assigned as the optimal nGVS amplitude. Optimal nGVS amplitudes could be determined for 13 out of 15 subjects, who were included in the subsequent experimental procedures. The effect of nGVS delivered at the determined optimal intensity on vestibular perceptual thresholds was examined using direction-recognition tasks on a motion platform, testing roll rotations at 0.2, 0.5, and 1.0 Hz, both with active and sham nGVS stimulations. nGVS significantly reduced direction-recognition thresholds compared to the sham condition at 0.5 and 1.0 Hz, while no significant effect of nGVS was found at 0.2 Hz. Interestingly, no correlation was found between nGVS-induced improvements in balance control and vestibular motion perception at 0.5 and 1 Hz, which may suggest different mechanisms by which nGVS affects both modalities. For the first time, we show that nGVS can enhance roll vestibular motion perception. The outcomes of this study are likely to be relevant for the potential therapeutic use of nGVS in patients with balance problems.
Collapse
|
49
|
Effect of noisy galvanic vestibular stimulation on center of pressure sway of static standing posture. Brain Stimul 2018; 11:85-93. [DOI: 10.1016/j.brs.2017.10.007] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2017] [Revised: 10/12/2017] [Accepted: 10/13/2017] [Indexed: 10/18/2022] Open
|
50
|
Noisy galvanic vestibular stimulation: an emerging treatment option for bilateral vestibulopathy. J Neurol 2017; 264:81-86. [DOI: 10.1007/s00415-017-8481-4] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Revised: 03/31/2017] [Accepted: 04/01/2017] [Indexed: 01/22/2023]
|