1
|
Chen JL, Njoku DI, Tang C, Gao Y, Chen J, Peng YK, Sun H, Mao G, Pan M, Tam NFY. Advances in Microfluidic Paper-Based Analytical Devices (µPADs): Design, Fabrication, and Applications. SMALL METHODS 2024:e2400155. [PMID: 38781604 DOI: 10.1002/smtd.202400155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 05/01/2024] [Indexed: 05/25/2024]
Abstract
Microfluidic Paper-based Analytical Devices (µPADs) have emerged as a new class of microfluidic systems, offering numerous advantages over traditional microfluidic chips. These advantages include simplicity, cost-effectiveness, stability, storability, disposability, and portability. As a result, various designs for different types of assays are developed and investigated. In recent years, µPADs are combined with conventional detection methods to enable rapid on-site detection, providing results comparable to expensive and sophisticated large-scale testing methods that require more time and skilled personnel. The application of µPAD techniques is extensive in environmental quality control/analysis, clinical diagnosis, and food safety testing, paving the way for on-site real-time diagnosis as a promising future development. This review focuses on the recent research advancements in the design, fabrication, material selection, and detection methods of µPADs. It provides a comprehensive understanding of their principles of operation, applications, and future development prospects.
Collapse
Affiliation(s)
- Jian Lin Chen
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
| | - Demian Ifeanyi Njoku
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Cui Tang
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Yaru Gao
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Jiayu Chen
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Yung-Kang Peng
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
| | - Hongyan Sun
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
| | - Guozhu Mao
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300350, P. R. China
| | - Min Pan
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Nora Fung-Yee Tam
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
| |
Collapse
|
2
|
Cabo J, Favresse J. Application of analytical performance specifications for urine test strip methods: Importance of reflectance signals. Clin Chim Acta 2023; 550:117534. [PMID: 37739023 DOI: 10.1016/j.cca.2023.117534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 09/01/2023] [Accepted: 09/01/2023] [Indexed: 09/24/2023]
Abstract
INTRODUCTION Urinalysis is essential for diagnosing kidney-related medical conditions. Urine test strip analysis serves as an initial and efficient screening method for reflex testing with accurate quantitative methods. MATERIALS AND METHODS Freshly voided urines (n = 206) were analysed using two urine test strip brands on UC-MAX (Menarini) and cobas u 601 (Roche Diagnostics) instruments. Ordinal scale categories and reflectance signals (if available) were both used for the comparison with reference quantitative methods for glucose, proteins and albumin (cobas 503). Samples were considered positive when glucose > 15 or ≥ 54 mg/dL, proteins ≥ 200 mg/L and albumin ≥ 10 mg/L. Optimized reflectance thresholds were calculated by ROC curve analysis. Analytical performance specifications (APS) for trueness of test strip were gathered from the EFLM guideline (FPD, FNG, FNC). RESULTS Reflectance signals were significantly lower in urine samples considered positive by the reference method (p < 0.0001). Reflectance signals were also correlated with quantitative measurements, showing strong correlation (0.754 to 0.969). Only the use of optimized reflectance thresholds on cobas u 601 achieved at least the minimum EFLM APS (FPD < 20%, FNG < 50% and FNC < 10%). CONCLUSION The use of reflectance signals from urine test strips enhanced accuracy for glucose, proteins, and albumin measurement and may contribute to improve diagnosis of diverse kidney-related conditions.
Collapse
Affiliation(s)
- Julien Cabo
- Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium.
| | - Julien Favresse
- Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium; Department of Pharmacy, Namur Research Institute for Life Sciences, Namur Thrombosis and Hemostasis Center, University of Namur, Namur, Belgium
| |
Collapse
|
3
|
Aper SJA, Gijzen K, Luimstra JJ, van der Valk JTMH, Russcher A, Koçer RG, Liesting EC, Jacobs LHJ, Lentjes EGWM, Demir AY. Evaluation of the Atellica ® UAS 800: a new member of the automated urine sediment analyzer family. Scandinavian Journal of Clinical and Laboratory Investigation 2021; 81:585-592. [PMID: 34686074 DOI: 10.1080/00365513.2021.1986856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
BACKGROUND In 2017 the Atellica® UAS 800 urine sediment analyzer was introduced by Siemens Healthineers. We investigated its applicability in the standardization and automation of the laboratory urinalysis workflow, including the prediction of urine culture outcome and glomerular pathology. METHODS We evaluated the performance characteristics of the Atellica® UAS 800 and its correlation with the iQ200 (Beckman Coulter). In addition, we studied the agreement between Atellica® UAS 800 and CLINITEK Novus® and determined the predictive value of bacteria and leukocyte counts for urine culture outcome. Furthermore, we investigated the ability of Atellica® UAS 800 to identify pathological casts and dysmorphic erythrocytes in comparison to manual microscopy. RESULTS Erythrocyte and leukocyte analyses indicated high intra- and inter-run precisions and good correlations with the iQ200. We found that the Atellica® UAS 800 detects bacteria with higher sensitivity than the iQ200. The Atellica® UAS 800 and CLINITEK Novus® showed a high degree of conformity. We determined seven combinations of clinical cut-off values of bacteria and leukocytes for predicting urine culture outcome with sensitivity, specificity, and negative predictive values of 95%, 52%, and 93%, respectively. Using the Atellica® UAS 800, hyaline casts, erythrocyte casts, leukocyte casts, and dysmorphic erythrocytes were correctly recognized in 76%, 22%, 2%, and 39% of the samples, respectively. CONCLUSIONS The Atellica® UAS 800 is a robust, fast, and user-friendly analyzer, which accurately quantifies erythrocytes, leukocytes, bacteria and squamous epithelial cells, and may be utilized for predicting positive urine cultures. The detection of clinically important pathological casts and dysmorphic erythrocytes proved insufficient.
Collapse
Affiliation(s)
- Stijn J A Aper
- Central Diagnostic Laboratory, University Medical Center, Utrecht, The Netherlands.,Laboratory for Clinical Chemistry, Hematology, and Immunology, Diakonessenhuis, Utrecht, The Netherlands
| | - Karlijn Gijzen
- Laboratory for Clinical Chemistry and Hematology, Meander Medical Centre, Amersfoort, The Netherlands
| | - Jolien J Luimstra
- Laboratory for Clinical Chemistry and Hematology, Meander Medical Centre, Amersfoort, The Netherlands
| | | | - Anne Russcher
- Laboratory for Medical Microbiology and Immunology, Meander Medical Centre, Amersfoort, The Netherlands
| | - Rüya G Koçer
- Laboratory for Clinical Chemistry and Hematology, Meander Medical Centre, Amersfoort, The Netherlands
| | - Eline C Liesting
- Central Diagnostic Laboratory, University Medical Center, Utrecht, The Netherlands
| | - Leo H J Jacobs
- Laboratory for Clinical Chemistry and Hematology, Meander Medical Centre, Amersfoort, The Netherlands
| | - Eef G W M Lentjes
- Central Diagnostic Laboratory, University Medical Center, Utrecht, The Netherlands
| | - Ayşe Y Demir
- Laboratory for Clinical Chemistry and Hematology, Meander Medical Centre, Amersfoort, The Netherlands
| |
Collapse
|
4
|
Cho J, Oh KJ, Jeon BC, Lee SG, Kim JH. Comparison of five automated urine sediment analyzers with manual microscopy for accurate identification of urine sediment. Clin Chem Lab Med 2020; 57:1744-1753. [PMID: 31280239 DOI: 10.1515/cclm-2019-0211] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2019] [Accepted: 06/01/2019] [Indexed: 11/15/2022]
Abstract
Background While the introduction of automated urine analyzers is expected to reduce the labor involved, turnaround time and potential assay variations, microscopic examination remains the "gold standard" for the analysis of urine sediments. In this study, we evaluated the analytical and diagnostic performance of five recently introduced automated urine sediment analyzers. Methods A total of 1016 samples were examined using five automated urine sediment analyzers and manual microscopy. Concordance of results from each automated analyzer and manual microscopy were evaluated. In addition, image and microscopic review rates of each system were investigated. Results The proportional bias for red blood cells (RBCs), white blood cells (WBCs) and squamous epithelial cells in the automated urine sediment analyzers were within ±20% of values obtained using the manual microscope, except in the cases of RBCs and WBCs analyzed using URiSCAN PlusScope and Iris iQ200SPRINT, respectively. The sensitivities of Roche Cobas® u 701 and Siemens UAS800 for pathologic casts (73.6% and 81.1%, respectively) and crystals (62.2% and 49.5%, respectively) were high, along with high image review rates (24.6% and 25.2%, respectively). The detection rates for crystals, casts and review rates can be changed for the Sysmex UF-5000 platform according to cut-off thresholds. Conclusions Each automated urine sediment analyzer has certain distinct features, in addition to the common advantages of reducing the burden of manual processing. Therefore, laboratory physicians are encouraged to understand these features, and to utilize each system in appropriate ways, considering clinical algorithms and laboratory workflow.
Collapse
Affiliation(s)
- Jooyoung Cho
- Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea.,Department of Laboratory Medicine, Yonsei University Wonju College of Medicine, Wonju, Korea
| | - Kyeong Jin Oh
- Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Beom Chan Jeon
- Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Sang-Guk Lee
- Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Jeong-Ho Kim
- Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
5
|
Paalanne N, Wikstedt L, Pokka T, Salo J, Uhari M, Renko M, Tapiainen T. Diaper-embedded urine test device for the screening of urinary tract infections in children: a cohort study. BMC Pediatr 2020; 20:378. [PMID: 32781982 PMCID: PMC7419204 DOI: 10.1186/s12887-020-02277-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Accepted: 08/05/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND There is a need for an easy and sensitive method for screening of urinary tract infections in young children. We set out to test whether a novel diaper-embedded urine test device is feasible and reliable in screening for urinary tract infections. METHODS This prospective cohort study consisted of young children examined due to a suspected acute urinary tract infection at the Pediatric Emergency Department of the Oulu University Hospital, Finland. We analyzed the same urine samples using three different methods: 1) a diaper-embedded test device applied to the urine pad within the diaper, 2) a urine sample aspirated from the urine pad for the conventional point-of-care dipstick test, and 3) a urine sample aspirated from the urine pad and analyzed in the laboratory with an automated urine chemistry analyzer. The gold standard for confirming urinary tract infection was quantitative bacterial culture. RESULTS Urine samples were available from 565 children. Bacterial culture confirmed urinary tract infection in 143 children. Sensitivity of the positive leukocyte screening of the diaper-embedded urine test device was 93.1% (95% CI: 87.4-96.8) and that of the point-of-care urine dipstick analysis was 95.4% (90.3-98.3) in those with both tests results available (n = 528). The sensitivity of the positive leukocyte test of the diaper-embedded test device was 91.4% (85.4-95.5) and that of the automated analysis was 88.5% (82.0-93.3) in those with both tests available (n = 547). The time to the test result after urination was immediate for the diaper-embedded test, 1-5 min for point-of-care dipstick, and 30-60 min for laboratory-based automated urine chemistry analyzer. CONCLUSIONS In this prospective study, the diaper-embedded urine test device was an easy and sensitive screening method for UTIs in young children. The main clinical benefit of the diaper-embedded urine test device was that the screening test result was available immediately after urination.
Collapse
Affiliation(s)
- Niko Paalanne
- Department of Pediatrics and Adolescent Medicine, Oulu University Hospital, Oulu, Finland. .,PEDEGO Research Unit and Medical Research Centre, University of Oulu, Oulu, Finland.
| | - Lotta Wikstedt
- Department of Pediatrics and Adolescent Medicine, Oulu University Hospital, Oulu, Finland.,PEDEGO Research Unit and Medical Research Centre, University of Oulu, Oulu, Finland
| | - Tytti Pokka
- Department of Pediatrics and Adolescent Medicine, Oulu University Hospital, Oulu, Finland.,PEDEGO Research Unit and Medical Research Centre, University of Oulu, Oulu, Finland
| | - Jarmo Salo
- Department of Pediatrics and Adolescent Medicine, Oulu University Hospital, Oulu, Finland.,PEDEGO Research Unit and Medical Research Centre, University of Oulu, Oulu, Finland
| | - Matti Uhari
- Department of Pediatrics and Adolescent Medicine, Oulu University Hospital, Oulu, Finland.,PEDEGO Research Unit and Medical Research Centre, University of Oulu, Oulu, Finland
| | - Marjo Renko
- Department of Pediatrics and Adolescent Medicine, Oulu University Hospital, Oulu, Finland.,PEDEGO Research Unit and Medical Research Centre, University of Oulu, Oulu, Finland.,Department of Pediatrics, University of Eastern Finland and Kuopio University Hospital, Kuopio, Finland
| | - Terhi Tapiainen
- Department of Pediatrics and Adolescent Medicine, Oulu University Hospital, Oulu, Finland.,PEDEGO Research Unit and Medical Research Centre, University of Oulu, Oulu, Finland.,Biocenter Oulu, University of Oulu, Oulu, Finland
| |
Collapse
|
6
|
Millán-Lou MI, García-Lechuz JM, Ruiz-Andrés MA, López C, Aldea MJ, Egido P, Revillo MJ, Rezusta A. Comparing Two Automated Techniques for the Primary Screening-Out of Urine Culture. Front Med (Lausanne) 2019; 5:353. [PMID: 30619863 PMCID: PMC6302016 DOI: 10.3389/fmed.2018.00353] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Accepted: 11/30/2018] [Indexed: 11/13/2022] Open
Abstract
Urinary tract infection is the most common human infection with a high morbidity. In primary care and hospital services, conventional urine culture is a key part of infection diagnosis but results take at least 24 h. Therefore, a rapid and reliable screening method is still needed to discard negative samples as quickly as possible and to reduce the laboratory workload. In this aspect, this study aims to compare the diagnostic performance between Sysmex UF-1000i and FUS200 systems in comparison to urine culture as the gold standard. From March to June 2016, 1,220 urine samples collected at the clinical microbiology laboratory of the “Miguel Servet” hospital were studied in parallel with both analysers, and some technical features were evaluated to select the ideal equipment. The most balanced cut-off values taking into account bacteria or leukocyte counts were 138 bacteria/μL or 119.8 leukocyte/μL for the UF-1000i (95.3% SE and 70.4% SP), and 5.7 bacteria/μL or 4.3 leukocyte/μL for the FUS200 (95.8% SE and 44.4% SP). The reduction of cultured plates was 37.4% with the FUS200 and 58.3% with the UF-1000i. This study shows that both techniques improve the workflow in the laboratory, but the UF-1000i has the highest specificity at any sensitivity and the FUS200 needs a shorter processing time.
Collapse
Affiliation(s)
- María Isabel Millán-Lou
- Servicio de Microbiología, Hospital Universitario Miguel-Servet, Zaragoza, Spain.,IIS Aragón, Zaragoza, Spain
| | | | | | - Concepción López
- Servicio de Microbiología, Hospital Universitario Miguel-Servet, Zaragoza, Spain
| | - María José Aldea
- Servicio de Microbiología, Hospital Universitario Miguel-Servet, Zaragoza, Spain
| | - P Egido
- Servicio de Microbiología, Hospital Universitario Miguel-Servet, Zaragoza, Spain
| | - María José Revillo
- Servicio de Microbiología, Hospital Universitario Miguel-Servet, Zaragoza, Spain
| | - Antonio Rezusta
- Servicio de Microbiología, Hospital Universitario Miguel-Servet, Zaragoza, Spain.,IIS Aragón, Zaragoza, Spain.,Department of Microbiología, Medicina Preventiva y Salud Pública, Universidad de Zaragoza, Zaragoza, Spain
| |
Collapse
|
7
|
Wesarachkitti B, Khejonnit V, Pratumvinit B, Reesukumal K, Meepanya S, Pattanavin C, Wongkrajang P. Performance Evaluation and Comparison of the Fully Automated Urinalysis Analyzers UX-2000 and Cobas 6500. Lab Med 2016; 47:124-33. [PMID: 27069030 DOI: 10.1093/labmed/lmw002] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVE To evaluate and compare the performances of the automated urinalysis devices UX-2000 and Cobas 6500. METHOD A total of 258 urine specimens were collected from the routine specimen workload. We analyzed all specimens on both automated instruments and recorded the turnaround time from each method. Physical, chemical, and sedimentary urine components were compared between the automated and the manual method for each analyzer. RESULTS The correlation of urine physical/chemical properties between the 2 instruments was excellent. The Cobas 6500 instrument demonstrated a higher level of agreement for red blood cells (Cobas 6500:R= 0.94; UX-2000:R= 0.78) and white blood cells (Cobas 6500:R= 0.95; UX-2000:R= 0.85). The UX-2000 demonstrated higher sensitivity for small round cells, hyaline casts, pathological casts, and bacteria. The median turnaround time was 1.5 minutes and 8.5 minutes for the Cobas 6500 and UX-2000, respectively. CONCLUSIONS The 2 devices showed similar performance in technical evaluation; they each reduce workload and increase time saving. However, manual examination by technicians is recommended for pathological specimens.
Collapse
Affiliation(s)
- Bongkot Wesarachkitti
- Department of Clinical Pathology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Varanya Khejonnit
- Department of Clinical Pathology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Busadee Pratumvinit
- Department of Clinical Pathology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Kanit Reesukumal
- Department of Clinical Pathology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Suriya Meepanya
- Department of Clinical Pathology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Chanutchaya Pattanavin
- Department of Clinical Pathology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Preechaya Wongkrajang
- Department of Clinical Pathology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| |
Collapse
|
8
|
van Delft S, Goedhart A, Spigt M, van Pinxteren B, de Wit N, Hopstaken R. Prospective, observational study comparing automated and visual point-of-care urinalysis in general practice. BMJ Open 2016; 6:e011230. [PMID: 27503860 PMCID: PMC4985791 DOI: 10.1136/bmjopen-2016-011230] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVE Point-of-care testing (POCT) urinalysis might reduce errors in (subjective) reading, registration and communication of test results, and might also improve diagnostic outcome and optimise patient management. Evidence is lacking. In the present study, we have studied the analytical performance of automated urinalysis and visual urinalysis compared with a reference standard in routine general practice. SETTING The study was performed in six general practitioner (GP) group practices in the Netherlands. Automated urinalysis was compared with visual urinalysis in these practices. Reference testing was performed in a primary care laboratory (Saltro, Utrecht, The Netherlands). PRIMARY AND SECONDARY OUTCOME MEASURES Analytical performance of automated and visual urinalysis compared with the reference laboratory method was the primary outcome measure, analysed by calculating sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) and Cohen's κ coefficient for agreement. Secondary outcome measure was the user-friendliness of the POCT analyser. RESULTS Automated urinalysis by experienced and routinely trained practice assistants in general practice performs as good as visual urinalysis for nitrite, leucocytes and erythrocytes. Agreement for nitrite is high for automated and visual urinalysis. κ's are 0.824 and 0.803 (ranked as very good and good, respectively). Agreement with the central laboratory reference standard for automated and visual urinalysis for leucocytes is rather poor (0.256 for POCT and 0.197 for visual, respectively, ranked as fair and poor). κ's for erythrocytes are higher: 0.517 (automated) and 0.416 (visual), both ranked as moderate. The Urisys 1100 analyser was easy to use and considered to be not prone to flaws. CONCLUSIONS Automated urinalysis performed as good as traditional visual urinalysis on reading of nitrite, leucocytes and erythrocytes in routine general practice. Implementation of automated urinalysis in general practice is justified as automation is expected to reduce human errors in patient identification and transcribing of results.
Collapse
Affiliation(s)
| | | | - Mark Spigt
- Maastricht University, Maastricht, The Netherlands
| | | | - Niek de Wit
- Julius Centre for Health Sciences and primary Care, University Medical Centre, Utrecht, The Netherlands
| | | |
Collapse
|
9
|
Ray EC, Abdel-Kader K, Bircher N, Rondon-Berrios H. Case report: proximal tubule impairment following volatile anesthetic exposure. Physiol Rep 2015; 3:3/9/e12560. [PMID: 26416976 PMCID: PMC4600399 DOI: 10.14814/phy2.12560] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
The safety of contemporary volatile anesthetic agents with respect to kidney function is well established, and growing evidence suggests that volatile anesthetics even protect against ischemic nephropathy. However, studies examining effects of volatile anesthetics on kidney function frequently demonstrate transient proteinuria and glycosuria following exposure to these agents, although the cause of these findings has not been thoroughly examined. We describe the case of a patient who underwent a neurosurgical procedure, then experienced glycosuria without hyperglycemia that resolved within days. Following a second neurosurgical procedure, the patient again developed glycosuria, now associated with ketonuria. Further examination demonstrated nonalbuminuric proteinuria in conjunction with urinary wasting of phosphate and potassium, indicative of proximal tubule impairment. We suggest that transient proximal tubule impairment may play a role in the proteinuria and glycosuria described following volatile anesthetic exposure and discuss the relationship between these observations and the ability of these agents to protect against ischemic nephropathy.
Collapse
Affiliation(s)
- Evan C Ray
- Renal-Electrolyte Division, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Khaled Abdel-Kader
- Division of Nephrology and Hypertension, Vanderbilt University, Nashville, Tennessee
| | - Nicholas Bircher
- Department of Anesthesiology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Helbert Rondon-Berrios
- Renal-Electrolyte Division, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| |
Collapse
|
10
|
Ko K, Kwon MJ, Ryu S, Woo HY, Park H. Performance Evaluation of Three URiSCAN Devices for Routine Urinalysis. J Clin Lab Anal 2015; 30:424-30. [PMID: 26303237 DOI: 10.1002/jcla.21874] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2014] [Accepted: 07/01/2015] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND This study compares the diagnostic performance (in routine urinalysis) of three URiSCAN devices and three Roche analyzers to manual microscopy and quantitative assays. METHODS We analyzed eight dipstick tests using three URiSCAN devices. The results were compared to those of the tests performed using three Roche analyzers. The results of leukocyte and erythrocyte screens were compared to those obtained using manual microscopy. Protein, glucose, pH, and specific gravity (SG) assays performed on the URiSCAN devices were compared with the results of corresponding quantitative assays. RESULTS The rates of agreement within one grade difference were found to be more than 94.3%. When compared with manual microscopy, the Optima provided better diagnostic performance for the detection of leukocytes compared with the Urisys 1100. Compared to the Urisys 2400, the Super plus provided better diagnostic performance with regard to both leukocytes and erythrocytes. There was good correlation between the three URiSCAN devices and each quantitative assay, except for SG detection. CONCLUSION There were well correlated results between those of the three URiSCAN devices and those obtained using the corresponding Roche analyzers, quantitative assays, and manual microscopy. URiSCAN series devices are therefore suitable for routine urinalysis in clinical laboratories.
Collapse
Affiliation(s)
- Kiwoong Ko
- Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Min-Jung Kwon
- Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Seungho Ryu
- Department of Occupational and Environmental Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University, School of Medicine, Seoul, Republic of Korea
| | - Hee-Yeon Woo
- Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
| | - Hyosoon Park
- Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| |
Collapse
|
11
|
Schot MJC, van Delft S, Kooijman-Buiting AMJ, de Wit NJ, Hopstaken RM. Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice. BMJ Open 2015; 5:e006857. [PMID: 25986635 PMCID: PMC4442241 DOI: 10.1136/bmjopen-2014-006857] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVE Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. SETTING All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. PRIMARY AND SECONDARY OUTCOME MEASURES Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. RESULTS The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. CONCLUSIONS The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice.
Collapse
Affiliation(s)
- Marjolein J C Schot
- University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht, The Netherlands
| | - Sanne van Delft
- Saltro, Diagnostic Center for Primary Care, Utrecht, The Netherlands
| | | | - Niek J de Wit
- University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht, The Netherlands
| | | |
Collapse
|
12
|
Hall IE, Coca SG, Perazella MA, Eko UU, Luciano RL, Peter PR, Han WK, Parikh CR. Risk of poor outcomes with novel and traditional biomarkers at clinical AKI diagnosis. Clin J Am Soc Nephrol 2011; 6:2740-9. [PMID: 22034509 DOI: 10.2215/cjn.04960511] [Citation(s) in RCA: 88] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
BACKGROUND AND OBJECTIVES Studies have evaluated acute kidney injury (AKI) using biomarkers in various settings, but their prognostic utility within current practice is unclear. Thus, we sought to determine the prognostic utility of newer biomarkers or traditional markers (fractional excretion of sodium [FeNa] and urea [FeUrea] and microscopy) over clinical assessment alone. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS This is a prospective cohort study of adults on the first day of meeting AKI criteria. We measured urine concentrations of neutrophil gelatinase-associated lipocalin (NGAL), kidney injury molecule-1 (KIM-1), and IL-18 and determined FeNa, FeUrea, and microscopy score for casts and tubular cells. Primary outcome was worsened AKI stage from enrollment to peak serum creatinine or in-hospital death. RESULTS In 249 recipients, 57% were ≥65 years old, 48% were from intensive care, and mean baseline GFR was 69 ± 30 ml/min per 1.73 m(2). AKI was considered prerenal in 164 (66%), acute tubular necrosis (ATN) in 51 (20%), and "other" in 34 (14%). All mean protein biomarker concentrations, FeNa, FeUrea, and microscopy scores were statistically different between prerenal and ATN. Seventy-two patients (29%) developed the primary outcome. There was an approximate three-fold increase in adjusted risk for the outcome for upper versus lower values of NGAL, KIM-1, IL-18, and microscopy score (P values <0.05). Net reclassification improved after adding these to baseline clinical assessment. FeNa and FeUrea were not useful. CONCLUSIONS On the first day of AKI, urine protein biomarkers and microscopy significantly improve upon clinical determination of prognosis, indicating their potential utility in current practice.
Collapse
Affiliation(s)
- Isaac E Hall
- Department of Medicine, Section of Nephrology, Yale University School of Medicine, New Haven, Connecticut, USA
| | | | | | | | | | | | | | | |
Collapse
|