1
|
Bistolfi A, Spezia M, Cipolla A, Bonera M, Mellano D, Banci L, Colombo M, Massè A. Vitamin E-stabilized polyethylene shows similar survival rates at minimum 7-year follow-up compared to conventional polyethylene in primary total knee arthroplasty. J Exp Orthop 2024; 11:e12106. [PMID: 39239569 PMCID: PMC11375329 DOI: 10.1002/jeo2.12106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2024] [Revised: 06/20/2024] [Accepted: 07/01/2024] [Indexed: 09/07/2024] Open
Abstract
Purpose The aim of this cross-sectional study was to compare survival, clinical and radiographic results of total knee arthroplasty (TKA) with vitamin E-stabilized polyethylene (VEPE) or conventional polyethylene (CPE) at a minimum of 7-year follow-up. Methods Patients who underwent primary TKA between 2011 and 2015, receiving the same cemented rotating platform knee design with VEPE or CPE tibial inserts, were identified. Patients were contacted for clinical and radiographic follow-up. American Knee Society Score (KSS), Forgotten Joint Score (FJS-12), presence of periprosthetic radiolucent lines (RLLs) and osteolysis were evaluated at the last follow-up. Any revision, reintervention or other complications were recorded. Results Among 350 TKAs initially identified, 102 VEPE and 97 CPE knees were included for analysis with mean follow-up of 8.5 and 8.3 years, respectively. No significant difference was found in survival rates at 10-year follow-up with revision due to aseptic loosening (95.0% vs. 97.8%, p = 0.29) or due to any reason (87.6% vs. 89.6%, p = 0.78) between VEPE and CPE TKA. KSS function score resulted significantly higher in the VEPE group over CPE (77 vs. 63, p = 0.01). RLLs were more frequent in VEPE than CPE (54% vs. 32%, p = 0.05), mainly noticed medially and posteriorly beneath the tibial plate, adjacent to the trochlear shield and the posterior condyles. Osteolysis was observed in one knee per group, but patients were asymptomatic with stable implants. Conclusion TKA with VEPE and CPE tibial inserts showed comparable survival rates, complications and clinical and radiographic results up to 10-year follow-up. Level of Evidence Level III.
Collapse
Affiliation(s)
| | - Marco Spezia
- Centro Ortopedico Quadrante Hospital Omegna Italy
| | | | | | | | - Lorenzo Banci
- Clinical Research Department Permedica Orthopaedics Merate Italy
| | - Marta Colombo
- Clinical Research Department Permedica Orthopaedics Merate Italy
| | - Alessandro Massè
- University of the Studies of Turin Turin Italy
- Department of Orthopaedics and Traumatology CTO AOU Città della Salute e della Scienza di Torino Turin Italy
| |
Collapse
|
2
|
Panez-Toro I, Heymann D, Gouin F, Amiaud J, Heymann MF, Córdova LA. Roles of inflammatory cell infiltrate in periprosthetic osteolysis. Front Immunol 2023; 14:1310262. [PMID: 38106424 PMCID: PMC10722268 DOI: 10.3389/fimmu.2023.1310262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 11/13/2023] [Indexed: 12/19/2023] Open
Abstract
Classically, particle-induced periprosthetic osteolysis at the implant-bone interface has explained the aseptic loosening of joint replacement. This response is preceded by triggering both the innate and acquired immune response with subsequent activation of osteoclasts, the bone-resorbing cells. Although particle-induced periprosthetic osteolysis has been considered a foreign body chronic inflammation mediated by myelomonocytic-derived cells, current reports describe wide heterogeneous inflammatory cells infiltrating the periprosthetic tissues. This review aims to discuss the role of those non-myelomonocytic cells in periprosthetic tissues exposed to wear particles by showing original data. Specifically, we discuss the role of T cells (CD3+, CD4+, and CD8+) and B cells (CD20+) coexisting with CD68+/TRAP- multinucleated giant cells associated with both polyethylene and metallic particles infiltrating retrieved periprosthetic membranes. This review contributes valuable insight to support the complex cell and molecular mechanisms behind the aseptic loosening theories of orthopedic implants.
Collapse
Affiliation(s)
- Isidora Panez-Toro
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Dominique Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
- The University of Sheffield, Dept of Oncology and Metabolism, Sheffield, United Kingdom
| | - François Gouin
- Department of Surgical Oncology, Centre Léon Bérard, Lyon, France
| | - Jérôme Amiaud
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
| | - Marie-Françoise Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Luis A. Córdova
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- IMPACT, Center of Interventional Medicine for Precision and Advanced Cellular Therapy, Santiago, Chile
- Oral and Maxillofacial Surgery, Clínica MEDS, Santiago, Chile
| |
Collapse
|
3
|
Siskey RL, Yarbrough RV, Spece H, Hodges SD, Humphreys SC, Kurtz SM. In Vitro Wear of a Novel Vitamin E Crosslinked Polyethylene Lumbar Total Joint Replacement. Bioengineering (Basel) 2023; 10:1198. [PMID: 37892928 PMCID: PMC10604298 DOI: 10.3390/bioengineering10101198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 10/06/2023] [Accepted: 10/12/2023] [Indexed: 10/29/2023] Open
Abstract
BACKGROUND A novel, lumbar total joint replacement (TJR) design has been developed to treat degeneration across all three columns of the lumbar spine (anterior, middle, and posterior columns). Thus far, there has been no in vitro studies that establish the preclinical safety profile of the vitamin E-stabilized highly crosslinked polyethylene (VE-HXLPE) lumbar TJR relative to historical lumbar anterior disc replacement for the known risks of wear and impingement faced by all motion preserving designs for the lumbar spine. QUESTIONS/PURPOSE In this study we asked, (1) what is the wear performance of the VE-HXLPE lumbar TJR under ideal, clean conditions? (2) Is the wear performance of VE-HXLPE in lumbar TJR sensitive to more aggressive, abrasive conditions? (3) How does the VE-HXLPE lumbar TJR perform under impingement conditions? METHOD A lumbar TJR with bilateral VE-HXLPE superior bearings and CoCr inferior bearings was evaluated under clean, impingement, and abrasive conditions. Clean and abrasive testing were guided by ISO 18192-1 and impingement was assessed as per ASTM F3295. For abrasive testing, CoCr components were scratched to simulate in vivo abrasion. The devices were tested for 10 million cycles (MC) under clean conditions, 5 MC under abrasion, and 1 MC under impingement. RESULT Wear rates under clean and abrasive conditions were 1.2 ± 0.5 and 1.1 ± 0.6 mg/MC, respectively. The VE-HXLPE components demonstrated evidence of burnishing and multidirectional microscratching consistent with microabrasive conditions with the cobalt chromium spherical counterfaces. Under impingement, the wear rates ranged between 1.7 ± 1.1 (smallest size) and 3.9 ± 1.1 mg/MC (largest size). No functional or mechanical failure was observed across any of the wear modes. CONCLUSIONS Overall, we found that that a VE-HXLPE-on-CoCr lumbar total joint replacement design met or exceeded the benchmarks established by traditional anterior disc replacements, with wear rates previously reported in the literature ranging between 1 and 15 mg/MC. CLINICAL RELEVANCE The potential clinical benefits of this novel TJR design, which avoids long-term facet complications through facet removal with a posterior approach, were found to be balanced by the in vitro tribological performance of the VE-HXLPE bearings. Our encouraging in vitro findings have supported initiating an FDA-regulated clinical trial for the design which is currently under way.
Collapse
Affiliation(s)
| | | | - Hannah Spece
- School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA 19104, USA
| | | | | | - Steven M. Kurtz
- School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA 19104, USA
| |
Collapse
|
4
|
Albahkali T, Abdo HS, Salah O, Fouly A. Adaptive Neuro-Fuzzy-Based Models for Predicting the Tribological Properties of 3D-Printed PLA Green Composites Used for Biomedical Applications. Polymers (Basel) 2023; 15:3053. [PMID: 37514443 PMCID: PMC10383854 DOI: 10.3390/polym15143053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 07/12/2023] [Accepted: 07/14/2023] [Indexed: 07/30/2023] Open
Abstract
Tribological performance is a critical aspect of materials used in biomedical applications, as it can directly impact the comfort and functionality of devices for individuals with disabilities. Polylactic Acid (PLA) is a widely used 3D-printed material in this field, but its mechanical and tribological properties can be limiting. This study focuses on the development of an artificial intelligence model using ANFIS to predict the wear volume of PLA composites under various conditions. The model was built on data gathered from tribological experiments involving PLA green composites with different weight fractions of date particles. These samples were annealed for different durations to eliminate residual stresses from 3D printing and then subjected to tribological tests under varying normal loads and sliding distances. Mechanical properties and finite element models were also analyzed to better understand the tribological results and evaluate the load-carrying capacity of the PLA composites. The ANFIS model demonstrated excellent compatibility and robustness in predicting wear volume, with an average percentage error of less than 0.01% compared to experimental results. This study highlights the potential of heat-treated PLA green composites for improved tribological performance in biomedical applications.
Collapse
Affiliation(s)
- Thamer Albahkali
- Mechanical Engineering Department, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia;
- The King Salman Center for Disability Research, Riyadh 11421, Saudi Arabia
| | - Hany S. Abdo
- Center of Excellence for Research in Engineering Materials (CEREM), Deanship of Scientific Research, King Saud University, Riyadh 11421, Saudi Arabia;
- Mechanical Design and Materials Department, Faculty of Energy Engineering, Aswan University, Aswan 81521, Egypt
| | - Omar Salah
- Department of Mechatronics, Faculty of Engineering, Assuit University, Assuit 71515, Egypt;
| | - Ahmed Fouly
- Mechanical Engineering Department, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia;
- Department of Production Engineering and Mechanical Design, Faculty of Engineering, Minia University, Minia 61519, Egypt
| |
Collapse
|
5
|
Shah NA, Lan RT, Dai R, Jiang K, Shen HY, Hong R, Xu JZ, Li L, Li ZM. Improved oxidation stability and crosslink density of chemically crosslinked ultrahigh molecular weight polyethylene using the antioxidant synergy for artificial joints. J Biomed Mater Res B Appl Biomater 2023; 111:26-37. [PMID: 35809250 DOI: 10.1002/jbm.b.35129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 05/28/2022] [Accepted: 06/27/2022] [Indexed: 02/05/2023]
Abstract
Vitamin E (VE) is currently an approved antioxidant to improve the oxidation stability of highly crosslinked ultrahigh molecular weight polyethylene (UHMWPE) insert used commercially in total joint arthroplasty. However, the decrease in crosslink density caused by VE reduces wear resistance of UHMWPE, showing an uncoordinated challenge. In this work, we hypothesized that D-sorbitol (DS) as a secondary antioxidant can improve the antioxidant efficacy of VE on chemically crosslinked UHMWPE. The combined effect of VE and DS on oxidation stability of UHMWPE was investigated at a set of controlled hybrid antioxidant content. The hybrid antioxidant strategy showed significantly synergistic enhancement on the oxidation stability of chemically crosslinked UHMWPE compared with the single VE strategy. More strikingly, the crosslink density of the blends with hybrid antioxidants stayed at a high level since DS is not sensitive to crosslinking. The relationships between oxidation stability, mechanical properties, crosslink density, and crystallinity were investigated, by which the clinically relevant overall performance of UHMWPE was optimized. This work provides a leading-edge design mean for the development of joint bearings.
Collapse
Affiliation(s)
- Nouman Ali Shah
- West China School of Nursing, Sichuan University/West China Hospital, Sichuan University, Chengdu, China.,College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, China
| | - Ri-Tong Lan
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, China
| | - Rui Dai
- College of Biomass Science and Engineering, Sichuan University, Chengdu, China
| | - Kai Jiang
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, China
| | - Hui-Yuan Shen
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, China
| | - Rui Hong
- West China School of Nursing, Sichuan University/West China Hospital, Sichuan University, Chengdu, China.,College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, China
| | - Jia-Zhuang Xu
- West China School of Nursing, Sichuan University/West China Hospital, Sichuan University, Chengdu, China.,College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, China
| | - Lingli Li
- West China School of Nursing, Sichuan University/West China Hospital, Sichuan University, Chengdu, China
| | - Zhong-Ming Li
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, China
| |
Collapse
|
6
|
Evaluating the Performance of 3D-Printed PLA Reinforced with Date Pit Particles for Its Suitability as an Acetabular Liner in Artificial Hip Joints. Polymers (Basel) 2022; 14:polym14163321. [PMID: 36015578 PMCID: PMC9416500 DOI: 10.3390/polym14163321] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 08/10/2022] [Accepted: 08/12/2022] [Indexed: 11/21/2022] Open
Abstract
Off-the-shelf hip joints are considered essential parts in rehabilitation medicine that can help the disabled. However, the failure of the materials used in such joints can cause individual discomfort. In support of the various motor conditions of the influenced individuals, the aim of the current research is to develop a new composite that can be used as an acetabular liner inside the hip joint. Polylactic acid (PLA) can provide the advantage of design flexibility owing to its well-known applicability as a 3D printed material. However, using PLA as an acetabular liner is subject to limitations concerning mechanical properties. We developed a complete production process of a natural filler, i.e., date pits. Then, the PLA and date pit particles were extruded for homogenous mixing, producing a composite filament that can be used in 3D printing. Date pit particles with loading fractions of 0, 2, 4, 6, 8, and 10 wt.% are dispersed in the PLA. The thermal, physical, and mechanical properties of the PLA–date pit composites were estimated experimentally. The incorporation of date pit particles into PLA enhanced the compressive strength and stiffness but resulted in a reduction in the elongation and toughness. A finite element model (FEM) for hip joints was constructed, and the contact stresses on the surface of the acetabular liner were evaluated. The FEM results showed an enhancement in the composite load carrying capacity, in agreement with the experimental results.
Collapse
|
7
|
Li X, Lu Y, Li J, Zhou S, Wang Y, Li L, Zhao F. Photoluminescent carbon dots (PCDs) from sour apple: a biocompatible nanomaterial for preventing UHMWPE wear-particle induced osteolysis via modulating Chemerin/ChemR23 and SIRT1 signaling pathway and its bioimaging application. J Nanobiotechnology 2022; 20:301. [PMID: 35761350 PMCID: PMC9235131 DOI: 10.1186/s12951-022-01498-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 06/07/2022] [Indexed: 11/10/2022] Open
Abstract
Photoluminescent nanomaterials have been widely employed in several biological applications both in vitro and in vivo. For the first time, we report a novel application of sour apple-derived photoluminescent carbon dots (PCDs) for reducing ultra-high molecular weight polyethylene (UHMWPE) wear particle-induced osteolysis using mouse calvarial model. Generally, aseptic prosthetic loosening seems to be a significant postoperative problem for artificial joints replacement, which is mainly contributed by UHMWPE-induced osteolysis. Hence, inhibiting osteoclastic bone-resorption could minimize UHMWPE-induced osteolysis for implant loosening. Prior to osteolysis studies, the prepared sour apple-derived PCDs were employed for bioimaging application. As expected, the prepared PCDs effectively inhibited the UHMWPE particle-induced osteoclastogenesis in vitro. The PCDs treatment effectively inhibited the UHMWPE-induced osteoclast differentiation, F-actin ring pattern, and bone resorption in vitro. Also, the PCDs reduced the UHMWPE-induced ROS stress as well as the expression level of pro-inflammatory cytokines, including TNF-α, IL-1, IL-6, and IL-8. Further, the qPCR and western blot results hypothesized that PCDs inhibited the UHMWPE wear particle-induced osteolysis through suppressing chemerin/ChemR23 signaling and NFATc1 pathway, along with upregulation of SIRT1 expression. Overall, these findings suggest that the synthesized PCDs could be a potential therapeutic material for minimizing UHMWPE particle-induced periprosthetic osteolysis to avoid postoperative complications.
Collapse
Affiliation(s)
- Xiang Li
- Department of Orthopaedic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, No.79 Qingchun Road, Hangzhou, 310003, People's Republic of China
| | - Yang Lu
- Department of Orthopaedic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, No.79 Qingchun Road, Hangzhou, 310003, People's Republic of China
| | - Jiarui Li
- Department of Orthopaedic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, No.79 Qingchun Road, Hangzhou, 310003, People's Republic of China
| | - Shengji Zhou
- Department of Orthopaedic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, No.79 Qingchun Road, Hangzhou, 310003, People's Republic of China
| | - Yuxin Wang
- Department of Orthopaedic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, No.79 Qingchun Road, Hangzhou, 310003, People's Republic of China
| | - Liangping Li
- Department of Surgery, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, 310003, People's Republic of China
| | - Fengchao Zhao
- Department of Orthopaedic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, No.79 Qingchun Road, Hangzhou, 310003, People's Republic of China.
| |
Collapse
|
8
|
Understanding the Role of Surface Modification of Randomized Trabecular Titanium Structures in Bone Tissue Regeneration: An Experimental Study. Medicina (B Aires) 2022; 58:medicina58020315. [PMID: 35208638 PMCID: PMC8879828 DOI: 10.3390/medicina58020315] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 02/07/2022] [Accepted: 02/14/2022] [Indexed: 11/26/2022] Open
Abstract
Background and Objectives: Three-dimensional (3D) metallic trabecular structures made by additive manufacturing (AM) technologies promote new bone formation and osteointegration. Surface modifications by chemical treatments can improve the osteoconductive properties of metallic structures. An in vivo study in sheep was conducted to assess the bone response to randomized trabecular titanium structures that underwent a surface modification by chemical treatment compared to the bone response to the untreated specimens. Material and Methods: Sixteen specimens with a randomized trabecular titanium structure were implanted in the spongious bone of the distal femur and proximal tibia and the cortical bone of the tibial diaphysis of two sheep. Of them, eight implants had undergone a chemical treatment (treated) and were compared to eight implants with the same structure but native surfaces (native). The sheep were sacrificed at 6 weeks. Surface features of the lattice structures (native and treated) were analyzed using a 3D non-contact profilometer. Compression tests of 18 lattice cubes were performed to investigate the mechanical properties of the two structures. Excellent biocompatibility for the trabecular structures was demonstrated in vitro using a cell mouse fibroblast culture. Histomorphometric analysis was performed to evaluate bone implant contact and bone ingrowth. Results: A compression test of lattice cubic specimens revealed a comparable maximum compressive strength value between the two tested groups (5099 N for native surfaces; 5558 N for treated surfaces; p > 0.05). Compared to native surfaces, a homogenous formation of micropores was observed on the surface of most trabeculae that increased the surface roughness of the treated specimens (4.3 versus 3.2 µm). The cellular viability of cells seeded on three-dimensional structure surfaces increased over time compared to that on plastic surfaces. The histomorphometric data revealed a similar behavior and response in spongious and cortical bone formation. The percentage of the implant surface in direct contact with the regenerated bone matrix (BIC) was not significantly different between the two groups either in the spongious bone (BIC: 27% for treated specimens versus 30% for native samples) or in the cortical bone (BIC: 75% for treated specimens versus 77% for native samples). Conclusions: The results of this study reveal rapid osseointegration and excellent biocompatibility for the trabecular structure regardless of surface treatment using AM technologies. The application of implant surfaces can be optimized to achieve a strong press-fit and stability, overcoming the demand for additional chemical surface treatments.
Collapse
|
9
|
Bjelić D, Finšgar M. Bioactive coatings with anti-osteoclast therapeutic agents for bone implants: Enhanced compliance and prolonged implant life. Pharmacol Res 2022; 176:106060. [PMID: 34998972 DOI: 10.1016/j.phrs.2022.106060] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/24/2021] [Accepted: 01/03/2022] [Indexed: 12/18/2022]
Abstract
The use of therapeutic agents that inhibit bone resorption is crucial to prolong implant life, delay revision surgery, and reduce the burden on the healthcare system. These therapeutic agents include bisphosphonates, various nucleic acids, statins, proteins, and protein complexes. Their use in systemic treatment has several drawbacks, such as side effects and insufficient efficacy in terms of concentration, which can be eliminated by local treatment. This review focuses on the incorporation of osteoclast inhibitors (antiresorptive agents) into bioactive coatings for bone implants. The ability of bioactive coatings as systems for local delivery of antiresorptive agents to achieve optimal loading of the bioactive coating and its release is described in detail. Various parameters such as the suitable concentrations, release times, and the effects of the antiresorptive agents on nearby cells or bone tissue are discussed. However, further research is needed to support the optimization of the implant, as this will enable subsequent personalized design of the coating in terms of the design and selection of the coating material, the choice of an antiresorptive agent and its amount in the coating. In addition, therapeutic agents that have not yet been incorporated into bioactive coatings but appear promising are also mentioned. From this work, it can be concluded that therapeutic agents contribute to the biocompatibility of the bioactive coating by enhancing its beneficial properties.
Collapse
Affiliation(s)
- Dragana Bjelić
- Faculty of Chemistry and Chemical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia.
| | - Matjaž Finšgar
- Faculty of Chemistry and Chemical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia.
| |
Collapse
|
10
|
Elbardesy H, Yadav H, Rabea M, Guerin S, Harty J. Femoral head penetration in Vitamin-E polyethylene liner versus conventional liners in total hip arthroplasty: systematic review and meta-analysis of randomised control trials. SICOT J 2021; 7:47. [PMID: 34515633 PMCID: PMC8436949 DOI: 10.1051/sicotj/2021045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 08/11/2021] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Debate encompasses the use of Vitamin E Polyethylene or conventional Polyethylene liner in primary hip arthroplasty. Does the Inclusion of Vitamin E in PE give adequate protection from oxidation and maintains lower rates of wear? PATIENTS AND METHODS We performed this study following the Preferred Reporting Items for Systematic Reviews and Meta-analyses Statement (PRISMA) and the Cochrane Handbook for systematic reviews and meta-analysis. Studies were included from any region, written in any language. We had only the randomised control trials comparing the femoral head penetration between Vitamin-E diffused highly cross-linked polyethylene (VEPE) liner and conventional liners in primary total hip arthroplasty. RESULTS We included 10 studies in this meta-analysis. We conducted them using Review Manager V.5.0. We computed the risk ratio to measure the treatment effect, considering the heterogeneity. We used Random-effect models. VEPE had insignificant marginal advantages for FHP within three months post-operative. Additionally, VEPE showed significantly less FHP after two and five years. After one year, it showed significantly less FHP with the VEPE group versus the UHMWPE cohort and a non-significant difference between the VEPE and XLPE group. CONCLUSIONS In terms of FHP, this metanalysis shows less FHP for the VEPE than conventional PE. A longer follow-up period is required to evaluate whether the oxidation protection gained by Vitamin E results in lower wear rates, less osteolysis, and aseptic loosening compared to the conventional PE in the long term.
Collapse
Affiliation(s)
- Hany Elbardesy
- Department of Trauma and Orthopaedic, Cork University Hospital, Wilton, Cork T12DFK4, Ireland
| | - Himanshu Yadav
- Department of Trauma and Orthopaedic, Cork University Hospital, Wilton, Cork T12DFK4, Ireland
| | - Mohamed Rabea
- Faculty of Pharmacy, Mansoura University, Mansoura 32216, Egypt
| | - Shane Guerin
- Department of Trauma and Orthopaedic, Cork University Hospital, Wilton, Cork T12DFK4, Ireland
| | - James Harty
- Department of Trauma and Orthopaedic, Cork University Hospital, Wilton, Cork T12DFK4, Ireland
| |
Collapse
|
11
|
Abstract
AbstractThe success of implant performance and arthroplasty is based on several factors, including oxidative stress-induced osteolysis. Oxidative stress is a key factor of the inflammatory response. Implant biomaterials can release wear particles which may elicit adverse reactions in patients, such as local inflammatory response leading to tissue damage, which eventually results in loosening of the implant. Wear debris undergo phagocytosis by macrophages, inducing a low-grade chronic inflammation and reactive oxygen species (ROS) production. In addition, ROS can also be directly produced by prosthetic biomaterial oxidation. Overall, ROS amplify the inflammatory response and stimulate both RANKL-induced osteoclastogenesis and osteoblast apoptosis, resulting in bone resorption, leading to periprosthetic osteolysis. Therefore, a growing understanding of the mechanism of oxidative stress-induced periprosthetic osteolysis and anti-oxidant strategies of implant design as well as the addition of anti-oxidant agents will help to improve implants’ performances and therapeutic approaches.
Collapse
|
12
|
Effects of Vitamin and Amino Acid-Enriched Hyaluronic Acid Gel on the Healing of Oral Mucosa: In Vivo and In Vitro Study. ACTA ACUST UNITED AC 2021; 57:medicina57030285. [PMID: 33803814 PMCID: PMC8003116 DOI: 10.3390/medicina57030285] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 03/11/2021] [Accepted: 03/16/2021] [Indexed: 01/06/2023]
Abstract
Background and Objectives: Wound healing is a dynamic process that can be compromised in patients with chronic and metabolic conditions or unhealthy lifestyles. Numerous medical substances designed for topical use, charged with compounds that promote the healing process, have been developed to improve wound healing, especially in compromised subjects. The present study aimed to extend our understanding of the in vivo effects of a hyaluronic acid gel charged with amino acids (HAplus gel, Aminogam gel® Errekappa Euroterapici spa, Milan, Italy) and study the in vitro effects of the same gel charged with additional substances in an attempt to optimize its formulation. Materials and Methods: In a randomized controlled split-mouth clinical and histological trial, HAplus gel was tested on the gingival tissue of the lower third molar post-extraction socket. The gingiva was collected at the time of extraction (T0) and ten days after the extraction (T1) to be histologically analyzed. During the second stage of the study, culture media with HAplus gel and vitamin C and E at different concentrations (TEST) were tested on human gingival fibroblasts and compared to the HAplus-enriched medium (HA-Control). Results: Histological and immunohistochemical analysis of collected gingiva showed higher microvascular density and collagen fibers organized in closely packed and well-oriented bundles in sites treated with HAplus gel. In the in vitro study, all TEST groups showed an increased viability from 24 h to 48 h. After 24 h, the viability percentage in all experimental groups was below 100% of the HA-Control, demonstrating a mild toxicity. After 48 h from seeding, the TEST groups’ viability grew significantly compared to HA-Control. Conclusions: These encouraging preliminary results suggest that the use of HAplus gel enriched with vitamins C and E may be beneficial in patients with conditions that impair soft tissue healing.
Collapse
|
13
|
Design of Wear-Resistant UHMWPE-Based Composites Loaded with Wollastonite Microfibers Treated with Various Silane Coupling Agents. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10134511] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The tribomechanical properties of the wear-resistant ultrahigh molecular weight polyethylene (UHMWPE)-based composites loaded with wollastonite microfibres silanized with various coupling agents (“KH-550”, “Penta-1006”, and “OTS”) were investigated. It was demonstrated that the mechanical properties of UHMWPE-based composites filled with various amounts of wollastonite (7–23 wt. %) increased by 1.3 times (yield strength) and by 1.8 times (elastic modulus), while the wollastonite silanization further improved yield strength by 9% in some cases. It was demonstrated that the composite loaded with 23 wt. % wollastonite silanized with the “KH-550” coupling agent possessed the maximum wear resistance under “moderate” conditions of tribological loading. Under “severe” conditions, the composites containing 23 wt. % wollastonite silanized with the less efficient “OTS” and “Penta-1006” agents showed the greatest wear resistance during dry sliding friction. Wear resistance significantly depended on filler weight fraction and the load–speed mode of the tribological tests. Based on the obtained experimental data on the mechanical (including impact toughness) and tribological properties of the UHMWPE-based composites loaded with wollastonite, the optimal compositions (the filler content and the type of the coupling agent) for two load–speed modes were designed using the developed computer algorithm. The composites provided the predefined high tribomechanical properties for operation in the metal-polymer friction units compared to neat polymer.
Collapse
|
14
|
Spece H, Schachtner JT, MacDonald DW, Klein GR, Mont MA, Lee GC, Kurtz SM. Reasons for Revision, Oxidation, and Damage Mechanisms of Retrieved Vitamin E-Stabilized Highly Crosslinked Polyethylene in Total Knee Arthroplasty. J Arthroplasty 2019; 34:3088-3093. [PMID: 31416742 PMCID: PMC6864268 DOI: 10.1016/j.arth.2019.07.018] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 07/11/2019] [Accepted: 07/14/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND In order to improve oxidation resistance, antioxidants such as vitamin-E are added to polyethylene used in the bearing surfaces of orthopedic components. Currently, little is known about the efficacy of this treatment in vivo. This study therefore reports on the reasons for revision, surface damage mechanisms, and oxidation of retrieved vitamin E-stabilized highly crosslinked polyethylene (HXLPE) for total knee arthroplasty. METHODS We examined 103 retrieved knee inserts fabricated from vitamin E (VE)-stabilized HXLPE and 67 fabricated from remelted HXLPE as a control. The implantation times were 1.2 ± 1.3 and 1.5 ± 1.3 years for the VE and control cohorts, respectively. The inserts were evaluated for 7 surface damage mechanisms using a semiquantitative scoring method and analyzed for oxidation using Fourier-transform infrared spectroscopy. Reasons for revision were also assessed using operative notes created at time of retrieval. RESULTS Both groups were revised primarily for instability, infection, and loosening. Burnishing, pitting, and scratching were the most common damage mechanisms observed, with the VE cohort demonstrating less surface damage than the control. Measured oxidation for the cohort was low, with a median oxidation index of 0.09 ± .05 for the articulating surface, 0.05 ± 0.06 for the backside, 0.08 ± 0.06 for the anterior/posterior surfaces, and 0.08 ± 0.05 for the stabilizing post. As compared to the control cohort, oxidation tended to be less for the VE group at the articulating (P < .001) and backside (P = .003) surfaces, although the median differences were minimal and may not be clinically significant. CONCLUSION The results indicate positive fatigue damage resistance and oxidation resistance for the retrieved VE-stabilized total knee arthroplasty inserts.
Collapse
Affiliation(s)
- Hannah Spece
- Implant Research Center at Drexel University, Philadelphia, PA
| | | | | | - Gregg R. Klein
- Hartzband Center for Hip and Knee Replacement, Paramus, NJ
| | | | - Gwo-Chin Lee
- Department of Orthopaedic Surgery, Penn Presbyterian Medical Center, University of Pennsylvania, Philadelphia, PA
| | - Steven M. Kurtz
- Implant Research Center at Drexel University, Philadelphia, PA,Exponent, Inc, Philadelphia, PA
| |
Collapse
|
15
|
Tuning the tribofilm nanostructures of polymer-on-metal joint replacements for simultaneously enhancing anti-wear performance and corrosion resistance. Acta Biomater 2019; 87:285-295. [PMID: 30682423 DOI: 10.1016/j.actbio.2019.01.038] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Revised: 12/14/2018] [Accepted: 01/17/2019] [Indexed: 02/08/2023]
Abstract
Total joint replacement is currently the most successful clinical treatment for improving the life quality of individuals afflicted with end-stage osteoarthritis of knee or hip joints. However, release of wear and corrosion products from the prostheses is a critical issue causing adverse physiological responses of local issues. β-SiC nanoparticles were dispersed into polyetheretherketone (PEEK) materials and their role in tribocorrosion performance of PEEK-steel joints exposed to simulated body fluid was investigated. It is demonstrated that β-SiC nanoparticles increase greatly the wear resistance of the PEEK materials, and meanwhile mitigate significantly corrosion of the steel counterpart. It is revealed that tribochemical reactions of β-SiC nanoparticles promoted formation of a robust tribofilm having complex structures providing protection and shielding effects. The present work proposes a strategy for developing high-performance polymer-on-metal joint replacement materials of enhanced lifespan and biocompatibility via tuning interface nanostructures. STATEMENT OF SIGNIFICANCE: Adverse tissue responses to metal wear and corrosion products from metal base implants remain a challenge to surgeons and patients. We demonstrated that leaching of metal ions and release of metallic debris are well decreased via tuning interface nanostructures of metal-polymer joint bearings by dispersing β-SiC nanoparticles into polyetheretherketone (PEEK). It is identified that the addition of β-SiC greatly improves the tribological performances of the PEEK materials and mitigated corrosion of the steel. Tribo-chemistry reactions of SiC induce the formation of complex structures which provide protection and shielding effects. Nanostructures of the tribofilm were also comprehensively investigated. These novel findings proposed a potential route for designing high performance metal-polymer joint replacement materials.
Collapse
|
16
|
Magnesium Filled Polylactic Acid (PLA) Material for Filament Based 3D Printing. MATERIALS 2019; 12:ma12050719. [PMID: 30823676 PMCID: PMC6427143 DOI: 10.3390/ma12050719] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 02/22/2019] [Accepted: 02/25/2019] [Indexed: 11/30/2022]
Abstract
The main objective of this research is to prove the viability of obtaining magnesium (Mg) filled polylactic acid (PLA) biocomposites as filament feedstock for material extrusion-based additive manufacturing (AM). These materials can be used for medical applications, thus benefiting of all the advantages offered by AM technology in terms of design freedom and product customization. Filaments were produced from two PLA + magnesium + vitamin E (α-tocopherol) compositions and then used for manufacturing test samples and ACL (anterior cruciate ligament) screws on a low-cost 3D printer. Filaments and implant screws were characterized using SEM (scanning electron microscopy), FTIR (fourier transform infrared spectrometry), and DSC (differential scanning calorimetry) analysis. Although the filament manufacturing process could not ensure a uniform distribution of Mg particles within the PLA matrix, a good integration was noticed, probably due to the use of vitamin E as a precursor. The results also show that the composite biomaterials can ensure and maintain implant screws structural integrity during the additive manufacturing process.
Collapse
|
17
|
Massaccesi L, Ragone V, Papini N, Goi G, Corsi Romanelli MM, Galliera E. Effects of Vitamin E-Stabilized Ultra High Molecular Weight Polyethylene on Oxidative Stress Response and Osteoimmunological Response in Human Osteoblast. Front Endocrinol (Lausanne) 2019; 10:203. [PMID: 31001202 PMCID: PMC6457167 DOI: 10.3389/fendo.2019.00203] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Accepted: 03/12/2019] [Indexed: 11/30/2022] Open
Abstract
High Crosslink process was introduced in the development of joint prosthetic devices, in order to decrease the wear rate of ultrahigh molecular weight polyethylene (UHMWPE), but it also triggers the formation of free radicals and oxidative stress, which affects the physiological bone remodeling, leading to osteolysis. Vitamin E stabilization of UHMWPE was proposed to provide oxidation resistance without affecting mechanical properties and fatigue strength. The aim of this study is to evaluate the antioxidant effect of vitamin E added to UHMWPE on oxidative stress induced osteolysis, focusing in particular on the oxidative stress response in correlation with the production of osteoimmunological markers, Sclerostin and DKK-1, and the RANKL/OPG ratio compared to conventional UHMWPE wear debris. Human osteoblastic cell line SaOS2 were incubated for 96 h with wear particles derived from crosslinked and not crosslinked Vitamin E-stabilized, UHMWPE without Vitamin E, and growth medium as control. Cellular response to oxidative stress, compared to not treat cells, was evaluated in terms of proteins O-GlcNAcylation, cellular levels of OGA, and OGT proteins by immunoblotting. O-GlcNAcylation and its positive regulator OGT levels are increased in the presence of Vitamin E blended UHMWPE, in particular with not crosslinked Vit E stabilized UHMWPE. Conversely, the negative regulator OGA increased in the presence of UHMWPE not blended with Vitamin E. Vitamin E-stabilized UHMWPE induced a decrease of RANKL/OPG ratio compared to UHMWPE without Vitamin E, and the same effect was observed for Sclerostin, while DKK-1 was not significantly affected. In conclusion, Vitamin E stabilization of UHMWPE increased osteoblast response to oxidative stress, inducing a cellular mechanism aimed at cell survival. Vitamin E antioxidant effect influences the secretion of osteoimmunological factors, shifting the bone turnover balance toward bone protection stimuli. This suggests that Vitamin E-Stabilization of UHMWPE could contribute to reduction of oxidation-induced osteolysis and the consequent loosening of the prosthetic devices, therefore improving the longevity of total joint replacements.
Collapse
Affiliation(s)
- Luca Massaccesi
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy
| | - Vincenza Ragone
- Research and Develpoment Department, Permedica S.p.A, Merate, Italy
| | - Nadia Papini
- Department of Medical Biotechnology and Traslational Medicine, Università degli Studi di Milano, Milan, Italy
| | - Giancarlo Goi
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, Milan, Italy
| | - Massimiliano Marco Corsi Romanelli
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy
- U.O.C SMEL-1 Patologia Clinica San Donato, IRCCS Policlinico San Donato, Milan, Italy
| | - Emanuela Galliera
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
- *Correspondence: Emanuela Galliera
| |
Collapse
|