Abusoglu S, Ecer B, Guven H, Yorulmaz AE, Serdar MA, Unlu A, Akyurek F, Ozturk B, Abusoglu G. End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6. Scand J Clin Lab Invest 2024; 84:183-192. [PMID: 38701073 DOI: 10.1080/00365513.2024.2344681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 04/12/2024] [Indexed: 05/05/2024]
Abstract
Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube (repeatability) and between-tube variation, concordance between comparison results of BD and VacuSEL tubes. Blood samples were collected from control subjects (n = 20) and patients (n = 30) in accordance with the CLSI GP41-A6 and CLSI GP34-A guidelines. Twenty-three clinical chemistry parameters were analysed via Roche Cobas C702 Chemistry Analyzer on T0 (0 hour) and T24 (24 hour). Mean differences % were compared with Wilcoxon matched pair test. Clinical significance was evaluated based on desirable bias according to total allowable error (TEa). VacuSEL tubes demonstrated acceptable performance for the results of 20 parameters with regards to desirable bias % limits. Lactate dehydrogenase (LD) [mean difference % (%95 confidence intervals (CI) values of BD and VacuSEL tubes at T0 [6.41% (4.80-8.01%)]; sodium (Na) and total protein (TP) at T24 [-0.27% (-0.46 to -0.07%) and -1.39% (-1.87 to -0.91), respectively] were over the desirable bias limits (LD: 4.3%, Na: 0.23% and TP: 1.36%, respectively) but not exceeding total biological variation CV % [Na: 0.5 (0.0-1.0) % and TP: 2.6 (2.3-2.7) %). %95 confidence intervals (CI) of T0 LD values overlap with within-subject biological variation % (CI) limits (LD: 5.2 (4.9-5.4) %). The differences between two tubes were not medically significant and necessarily conclusive. VacuSEL serum tubes presented comparable performance with BD serum tubes.
Collapse
Affiliation(s)
- Sedat Abusoglu
- Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey
| | - Busra Ecer
- Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey
| | - Halil Guven
- Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey
| | - Ahmet Emre Yorulmaz
- Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey
| | | | - Ali Unlu
- Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey
| | - Fikret Akyurek
- Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey
| | - Bahadir Ozturk
- Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey
| | - Gulsum Abusoglu
- Department of Medical Laboratory Techniques, Selcuk University Vocational School of Health, Konya, Turkey
| |
Collapse
|
2
|
Rosada A, Prpic M, Spieß E, Friedrich K, Neuwinger N, Müller-Werdan U, Kappert K. Underfilled blood collection tubes as pathologizing factor for measured laboratory parameters in older patients. J Am Geriatr Soc 2024; 72:1553-1556. [PMID: 38314861 DOI: 10.1111/jgs.18790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 01/02/2024] [Accepted: 01/07/2024] [Indexed: 02/07/2024]
Affiliation(s)
- Adrian Rosada
- Department of Geriatrics and Medical Gerontology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Monika Prpic
- Institute of Diagnostic Laboratory Medicine, Clinical Chemistry and Pathobiochemistry, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Eileen Spieß
- Department of Geriatrics and Medical Gerontology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Katharina Friedrich
- Institute of Diagnostic Laboratory Medicine, Clinical Chemistry and Pathobiochemistry, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Nick Neuwinger
- Institute of Diagnostic Laboratory Medicine, Clinical Chemistry and Pathobiochemistry, Charité-Universitätsmedizin Berlin, Berlin, Germany
- Labor Berlin-Charité Vivantes GmbH, Berlin, Germany
| | - Ursula Müller-Werdan
- Department of Geriatrics and Medical Gerontology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Kai Kappert
- Institute of Diagnostic Laboratory Medicine, Clinical Chemistry and Pathobiochemistry, Charité-Universitätsmedizin Berlin, Berlin, Germany
- Labor Berlin-Charité Vivantes GmbH, Berlin, Germany
| |
Collapse
|
3
|
Aksit M, Zeytinli Aksit M, Colak A, Isbilen Basok B, Ceylan C. Stability of potassium, calcium and phosphorus electrolytes in three different tubes in patients with essential thrombocytosis. Scand J Clin Lab Invest 2023; 83:582-590. [PMID: 38063345 DOI: 10.1080/00365513.2023.2289162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 11/15/2023] [Accepted: 11/26/2023] [Indexed: 01/25/2024]
Abstract
Proper blood collection and timely analysis are vital steps for reliable results. This study aims to compare potassium(K), calcium(Ca), and phosphorus(P) concentrations in serum separator tube (SST), lithium heparin tube without gel (LiH), and lithium heparin tube with a barrier (Barricor)tubes in essential thrombocytosis(ET) patients. Additionally, we assessed short-term stability of these analytes at room temperature. K, Ca and P concentrations of blood taken from 40 ET patients into SST, LiH and Barricor tubes were measured at 0, 2, 4 and 8 h. We calculated the percentage difference and defined the maximum permissible difference (MPD) using the Biological Variation Database. Intertube comparisons were conducted using Passing-Bablok regression and Bland-Altman analysis. Comparing SST to LiH, the percentage difference values for all tests exceeded the MPD. When comparing Barricor to LiH, K and Ca tests were above MPD, except for P. At the 8th hour, LiH showed clinically significant changes in all three electrolytes. Barricor exhibited stability for K, Ca, and P for up to 8 h, with only Ca levels borderline higher than the MPD. Our study reveals clinically significant alterations in K, Ca, and P concentrations in SST compared to LiH tubes, and in K and Ca concentrations in Barricor compared to LiH tubes. While K, Ca and P concentrations were stable for up to 4 h at room temperature in all tube types tested, significant changes were observed in all electrolytes at 8 h in the LiH tube.
Collapse
Affiliation(s)
- Murat Aksit
- Medical Biochemistry Department, University of Health Sciences, Tepecik Training and Research Hospital, Izmir, Turkey
| | - Merve Zeytinli Aksit
- Medical Biochemistry Department, Bakircay University, Cigli Training and Research Hospital, Izmir, Turkey
| | - Ayfer Colak
- Medical Biochemistry Department, University of Health Sciences, Tepecik Training and Research Hospital, Izmir, Turkey
| | - Banu Isbilen Basok
- Medical Biochemistry Department, University of Health Sciences, Izmir Faculty of Medicine, Dr. Behcet Uz Child Disease and Pediatric Surgery Training and Research Hospital, Izmir, Turkey
| | - Cengiz Ceylan
- Hematology Department, University of Health Sciences, Tepecik Training and Research Hospital, Izmir, Turkey
| |
Collapse
|
4
|
Cembrowski G, Qiu Y, Sherazi A, Shea JL. Retrospective analysis of intra-patient laboratory variation demonstrates that the BD Vacutainer® Barricor™ blood collection tube reduces troponin variation. Clin Biochem 2023; 114:24-29. [PMID: 36706798 DOI: 10.1016/j.clinbiochem.2023.01.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 11/14/2022] [Accepted: 01/23/2023] [Indexed: 01/26/2023]
Abstract
OBJECTIVE The BD Vacutainer® Barricor™ plasma blood collection tube uses a mechanical separator during centrifugation to separate plasma from the cellular elements of blood. Compared to use of plasma separator tubes (PST™) with gel, Barricor™ produces a cleaner sample with less residual cellular content. We sought to determine if Barricor™ reduces pre-analytical error compared to PST™. DESIGN & METHODS We used a model previously published that utilizes serial differences between intra-patient measurements transformed into a Taylor series of variation vs time with the y-intercept equal to the sum of short-term analytic variation, preanalytic variation and biologic variation. The intra-patient variation of chloride, sodium, potassium, and troponin-T (hs-TnT) obtained from the Emergency Department of a large tertiary care center sampled with PST™ (May 2015-April 2018, n = 59,762 specimens) or Barricor™ (May 2018-May 2021, n = 61,512 specimens) was evaluated. All specimens were analyzed on either Roche Modular or Cobas® instruments. For each analyte, pairs of intra-patient results were tabulated and separated by 1 h intervals. The average between-pair variations were then regressed against time. We also determined the number of intra-patient outliers using the reference change value for each analyte. RESULTS The Barricor™ hs-TnT y-intercept (-0.0132) was significantly lower than the PST™ intercept (0.9109; p = 0.022). This was also true for chloride (y-intercept = 1.0067 in Barricor™ and 1.3431 in PST™, p = 0.037). The percentage of hs-TnT outliers was significantly lower in Barricor™ (8.32 %) vs PST™ (12.2 %; p < 0.001). CONCLUSION The analytical and biological variations are assumed to be steady over the study periods; we ascribe the difference in the y-intercept to the preanalytical effect of the Barricor™ tube reducing platelets and other cellular debris.
Collapse
Affiliation(s)
- George Cembrowski
- Laboratory Medicine and Pathology, University of Alberta, Cembrowski & Cembrowski Quality Control Consulting, Edmonton, AB, Canada
| | - Yuelin Qiu
- Faculty of Medicine, University of Alberta, Edmonton, AB, Canada
| | - Ali Sherazi
- Department of Research Services, Saint John Regional Hospital, Horizon Health Network, Saint John, NB, Canada; Department of Laboratory Medicine, Saint John Regional Hospital, Horizon Health Network, Saint John, NB, Canada
| | - Jennifer L Shea
- Department of Laboratory Medicine, Saint John Regional Hospital, Horizon Health Network, Saint John, NB, Canada; Department of Pathology, Dalhousie University, Halifax, NS, Canada.
| |
Collapse
|
5
|
Knutti N, Neugebauer S, Scherr F, Mathay C, Marchese M, Henry E, Palm J, Betsou F, Kiehntopf M. Introduction of BD Vacutainer ® Barricor™ tubes in clinical biobanking and application of amino acid and cytokine quality indicators to Barricor plasma. Clin Chem Lab Med 2022; 60:689-700. [PMID: 35073617 DOI: 10.1515/cclm-2021-0899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Accepted: 01/10/2022] [Indexed: 01/04/2024]
Abstract
OBJECTIVES The use of BD Vacutainer® Barricor™ tubes (BAR) can reduce turnaround time (TAT) and improve separation of plasma from cellular components using a specific mechanical separator. Concentrations of amino acids (AAs) and cytokines, known to be labile during pre-analytical time delays, were compared in heparin (BAR, BD Heparin standard tube [PST]), EDTA and serum gel tubes (SER) to validate previously identified quality indicators (QIs) in BAR. METHODS Samples of healthy individuals (n=10) were collected in heparin, EDTA and SER tubes and exposed to varying pre- and post-centrifugation delays at room temperature (RT). Cytokines (interleukin [IL]-8, IL-16 and sCD40L) were analyzed by enzyme-linked immunosorbent assay (ELISA) and AAs were characterized by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). RESULTS All QIs, AAs/AA ratio and cytokines increased during prolonged blood storage in heparin plasma (PST, BAR) and SER tubes. Comparison of 53 h/1 h pre-centrifugation delay resulted in an increase in taurine (Tau) and glutamic acid (Glu) concentrations by more than three times, soluble CD40L increased by 13.6, 9.2 and 4.3 fold in PST, BAR-CTRL and BAR-FAST, and IL-8 increased even more by 112.8 (PST), 266.1 (BAR-CTRL), 268.1 (BAR-FAST) and 70.0 (SER) fold, respectively. Overall, compared to prolonged blood storage, effects of post-centrifugation delays were less pronounced in all tested materials. CONCLUSIONS BAR tubes are compatible with the use of several established QIs and can therefore be used in clinical biobanking to reduce pre-analytical TAT without compromising QIs and thus pre-analytical sample quality analysis.
Collapse
Affiliation(s)
- Nadine Knutti
- Institute of Clinical Chemistry and Laboratory Diagnostics, Jena University Hospital, Jena, Germany
| | - Sophie Neugebauer
- Institute of Clinical Chemistry and Laboratory Diagnostics, Jena University Hospital, Jena, Germany
| | - Franziska Scherr
- Institute of Clinical Chemistry and Laboratory Diagnostics, Jena University Hospital, Jena, Germany
| | - Conny Mathay
- Integrated BioBank of Luxembourg (IBBL), Dudelange, Luxembourg
| | - Monica Marchese
- Integrated BioBank of Luxembourg (IBBL), Dudelange, Luxembourg
| | - Estelle Henry
- Integrated BioBank of Luxembourg (IBBL), Dudelange, Luxembourg
| | - Julia Palm
- Institute of Medical Statistics, Computer and Data Science, Jena University Hospital, Jena, Germany
| | - Fay Betsou
- Integrated BioBank of Luxembourg (IBBL), Dudelange, Luxembourg
- Laboratoire National de Santé (LNS), Dudelange, Luxembourg
| | - Michael Kiehntopf
- Institute of Clinical Chemistry and Laboratory Diagnostics and Integrated Biobank Jena (IBBJ), Jena University Hospital, Jena, Germany
| |
Collapse
|
6
|
Khoza SP, Ford S, Buthelezi EP, Tanyanyiwa DM. Comparative study of chemical pathology sample collection tubes at the largest hospital in South Africa. J Med Biochem 2021; 40:358-366. [PMID: 34616225 PMCID: PMC8451222 DOI: 10.5937/jomb0-27216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Accepted: 02/15/2021] [Indexed: 11/16/2022] Open
Abstract
Background BarricorTM Lithium heparin plasma tubes are new blood tubes that have been introduced to overcome the effects of gel in serum separator tubes (SST) and the shortcomings of standard Lithium heparin plasma. We aimed to evaluate BarricorTM tubes as an alternative to serum separator tubes and compare the stability between the tubes. Methods Forty-four paired samples were collected using both BarricorTM and SST. We compared five analytes at baseline (<6 h) and after every 24 h using the PassingBablok and Bland-Altman plots. Aspartate aminotransferase (AST), potassium (K), phosphate (PO4) , lactate dehydrogenase (LDH), and creatinine were analysed in both tubes. We calculated the percentage difference for each analyte between the baseline and time intervals to assess analyte stability. The percentage difference was compared to the desirable specification for bias and reference change value (RCV). Results All analytes were comparable at baseline. Statistical differences (p<0.001) became evident after 24 h. PO4, K, and creatinine had a mean difference that exceeded the desirable specification for bias (-9.59%, - 9.35%, and -4.59%, respectively). Potassium was stable up to 24 h in both tubes. LDH showed better stability in SST (144 h vs 96 h). PO4 concentrations were more stable in both tubes with the SST (96 h vs 72 h). Creatinine and AST had the longest stability in both tubes compared to other analytes (144 h). Conclusions Data demonstrated variability and similarities in analyte concentrations and stability, respectively, in both tubes.
Collapse
Affiliation(s)
| | - Sarah Ford
- National Health Laboratory Service, Department of Chemical Pathology, Johannesburg, South Africa
| | | | - Donald M Tanyanyiwa
- Sefako Makgatho University of Health Sciences, Pretoria, South Africa.,National Health Laboratory Service, Department of Chemical Pathology, Johannesburg, South Africa
| |
Collapse
|
7
|
Hétu PO, Hobeila S, Larivière F, Bélanger MC. Improved Sample Quality and Decreased Turnaround Time When Using Plasma Blood Collection Tubes with a Mechanical Separator in a Large University Hospital. J Appl Lab Med 2021; 6:409-420. [PMID: 32989467 DOI: 10.1093/jalm/jfaa111] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Accepted: 06/01/2020] [Indexed: 12/27/2022]
Abstract
BACKGROUND Serum is commonly used for clinical chemistry testing but many conditions can affect the clotting process, leading to poor sample quality and impaired workflow. With serum gel tubes, we found a high proportion of sample probe aspiration errors on our Beckman AU5800 analyzers. We decided to implement the BD Barricor™ plasma tubes, and we validated an off-specification centrifugation scheme and verified that results obtained for 65 chemistry and immunochemistry tests were comparable to those obtained in serum gel tubes. Finally, we evaluated the impact of this new tube on sample error rate and laboratory turnaround time. METHODS To validate centrifugation settings, 50 paired samples were collected in Barricor tubes and centrifuged at 1912 × g for 10 min or 5 min (off-specification). To compare serum gel tubes with Barricor plasma tubes, 119 paired samples were collected from volunteers and results were analyzed using weighed Deming regression. Finally, the proportion of aspiration errors and laboratory TAT for potassium were measured before and after implementing Barricor tubes. RESULTS Barricor tubes showed clinically acceptable equivalence to serum gel tubes for the studied analytes, and the off-specification centrifugation scheme did not affect the results. Implementing Barricor tubes improved the laboratory workflow by decreasing the aspiration error rates (2.01% to 0.77%, P < 0.001) and lowering hemolysis (P < 0.001). The laboratory TAT for potassium were also significantly lowered (P < 0.001). CONCLUSION Use of Barricor tubes instead of serum gel tubes leads to better sample quality, shorter more reproducible laboratory TAT, and decreases costs associated with error management.
Collapse
Affiliation(s)
- Pierre-Olivier Hétu
- Department of Laboratory Medecine, Centre Hospitalier de l'Université de Montréal (CHUM), Montreal, Quebec, Canada.,CHUM Research Centre (CRCHUM), Montreal, Quebec, Canada
| | - Sacha Hobeila
- Department of Laboratory Medecine, Centre Hospitalier de l'Université de Montréal (CHUM), Montreal, Quebec, Canada
| | - François Larivière
- Department of Laboratory Medecine, Centre Hospitalier de l'Université de Montréal (CHUM), Montreal, Quebec, Canada
| | - Marie-Claire Bélanger
- Department of Laboratory Medecine, Centre Hospitalier de l'Université de Montréal (CHUM), Montreal, Quebec, Canada.,CHUM Research Centre (CRCHUM), Montreal, Quebec, Canada
| |
Collapse
|
8
|
Raizman JE, Tsui AK, Goudreau BL, Füzéry AK, Estey M, Sadrzadeh H, Higgins T. Multi-platform analytical evaluation of the Beckman Coulter Access high-sensitivity troponin I assay across different laboratory sites using Barricor plasma. Clin Biochem 2020; 78:25-31. [DOI: 10.1016/j.clinbiochem.2019.10.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 10/22/2019] [Accepted: 10/22/2019] [Indexed: 11/25/2022]
|
9
|
Gawria G, Tillmar L, Landberg E. A comparison of stability of chemical analytes in plasma from the BD Vacutainer ® Barricor™ tube with mechanical separator versus tubes containing gel separator. J Clin Lab Anal 2019; 34:e23060. [PMID: 31605419 PMCID: PMC7031586 DOI: 10.1002/jcla.23060] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 08/20/2019] [Accepted: 09/10/2019] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND There is a need of prolonged stability of certain chemical analytes in lithium heparin tubes with separators. A new tube with a mechanical separator has recently been launched (Barricor™), which according to the manufacturer may have these benefits. The aim of this study was to evaluate stability performance of this tube in comparison with plasma gel tubes under clinically realistic circumstances. METHODS Blood was collected in tubes containing lithium heparin with different separators; gel separator (Vacutainer® PST™, Becton Dickinson and Vacuette® , Greiner bio-one) and mechanical separator (Vacutainer® Barricor™, Becton Dickinson). All tubes had an aspiration volume of 3 mL and were centrifuged at similar time and force. Tubes were transported manually or by car. Seven analytes from 122 patients were analyzed after 3 to 80 hours by Cobas c701 (Roche). RESULTS The Barricor™ tube showed increased stability of phosphate and potassium and similar stability of aspartate aminotransferase, glucose, homocysteine, lactate dehydrogenase, and magnesium compared with gel tubes. Maximal allowable bias for phosphate was exceeded after 68 hours for Barricor™ tubes compared with 29 or 35 hours for gel tubes and for potassium after 40 hours for Barricor™ tubes vs 9 or 12 hours for gel tubes. Transportation did not affect stability. Hemolysis index was slightly lower in Barricor tubes than in gel tubes (P = .01). CONCLUSION Implementing the new Barricor™ tube will improve stability of potassium and phosphate in plasma. Blood sampling facilities far from the laboratory may benefit from using these tubes, thus diminishing preanalytical errors.
Collapse
Affiliation(s)
- Ghassaan Gawria
- Department of Clinical Chemistry and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
| | - Linda Tillmar
- Department of Clinical Chemistry and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
| | - Eva Landberg
- Department of Clinical Chemistry and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
| |
Collapse
|