1
|
Cheng F, Lv B, Huang Y, Tang Y, Mei D, Huang B, Zhao X. Facile Synthesis and Characterization of Fluorescent Polystyrene Nanospheres for Homogeneous Light-Initiated Chemiluminescence Immunoassay. J Fluoresc 2024. [DOI: 10.1007/s10895-024-03965-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Accepted: 09/26/2024] [Indexed: 01/04/2025]
|
2
|
Chen M, Fang H, Wu J, Huang Y, Cheng F, Qin Y, Zhao X, Zhou X, Liu P, Huang B. Establishment of trypsinogen-2 Amplification Luminescent Proximity Homogeneous Assay and its Application in Acute Pancreatitis. J Fluoresc 2024:10.1007/s10895-024-03917-0. [PMID: 39235654 DOI: 10.1007/s10895-024-03917-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2024] [Accepted: 08/20/2024] [Indexed: 09/06/2024]
Abstract
We aim to develop an amplified luminescence proximity homogeneous assay (AlphaLISA) for quantification of trypsinogen-2 levels in human serum for the diagnosis of acute pancreatitis. Based on new amplified luminescence proximity homogeneity assay (AlphaLISA) method, carboxyl-modified donor and acceptor beads were coupled to capture and detection antibodies. A double antibody sandwich immunoassay was used to detect the concentration of trypsinogen-2 in serum. The method had good linearity (> 0.998). The intra - analysis precision was between 1.54% and 2.20% (< 10%), the inter-analysis precision was between 3.17% and 6.94% (< 15%), and the recovery was between 96.23% and 103.45%. The cross-reactivity of carbohydrate antigen 242 (CA242) and T-cell immunoglobulin mucin-3 (Tim-3) were 0.09% and 0.93%, respectively. The detection time only needed 15 min. The results of trypsinogen-2-AlphaLISA and time-resolved fluorescence immunoassay were consistent (ρ = 0.9019). In addition, serum trypsinogen-2 concentration in patients with acute pancreatitis [239.23 (17.83-807.58) ng/mL] was significantly higher than that in healthy controls [20.54 (12.10-39.73) ng/mL]. When the cut-off value was 35.38ng/mL, the sensitivity and specificity were 91.8% and 96.67%, and the positive detection rate was 91.80%. We have successfully established a trypsinogen-2-AlphaLISA method, which can promote the timely diagnosis of acute pancreatitis.
Collapse
Affiliation(s)
- Meichun Chen
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Hongming Fang
- Affiliated Xiaoshan Hospital, Hangzhou Normal University, Hangzhou, China
| | - Jialong Wu
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Yue Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Feifan Cheng
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Yuan Qin
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Xueqin Zhao
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Xiumei Zhou
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Pengfei Liu
- Department of Gastroenterology, The Jiangyin Clinical College of Xuzhou Medical University, Wuxi, People's Republic of China
| | - Biao Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| |
Collapse
|
3
|
Zhao C, Zhang Z, Li J, Lu Y, Ma F, Wang Z, Geng J, Huang B, Qin Y. Development of a Quick and Highly Sensitive Amplified Luminescent Proximity Homogeneous Assay for Detection of Saxitoxin in Shellfish. Toxins (Basel) 2024; 16:341. [PMID: 39195751 PMCID: PMC11360761 DOI: 10.3390/toxins16080341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Revised: 07/30/2024] [Accepted: 07/30/2024] [Indexed: 08/29/2024] Open
Abstract
Saxitoxin (STX), an exceptionally potent marine toxin for which no antidote is currently available, is produced by methanogens and cyanobacteria. This poses a significant threat to both shellfish aquaculture and human health. Consequently, the development of a rapid, highly sensitive STX detection method is of great significance. The objective of this research is to create a novel approach for identifying STX. Therefore, amplified luminescent proximity homogeneous assay (AlphaLISA) was established using a direct competition method based on the principles of fluorescence resonance energy transfer and antigen-antibody specific binding. This method is sensitive, rapid, performed without washing, easy to operate, and can detect 8-128 ng/mL of STX in only 10 min. The limit of detection achieved by this method is as low as 4.29 ng/mL with coefficients of variation for the intra-batch and inter-batch analyses ranging from 2.61% to 3.63% and from 7.67% to 8.30%, respectively. In conclusion, our study successfully establishes a simple yet sensitive, rapid, and accurate AlphaLISA method for the detection of STX which holds great potential in advancing research on marine biotoxins.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Biao Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, China; (C.Z.); (Z.Z.); (J.L.); (Y.L.); (Z.W.); (J.G.)
| | - Yuan Qin
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, China; (C.Z.); (Z.Z.); (J.L.); (Y.L.); (Z.W.); (J.G.)
| |
Collapse
|
4
|
Tang Y, Chen F, Lv W, Zhou Z, Fu Y, Qin Y, Zhao X, Wang J, Huang B. Establishment of a microspheres-based homogeneous fluorescence immunoassay for the rapid detection of cardiac troponin I. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:4402-4408. [PMID: 38904182 DOI: 10.1039/d4ay00921e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/22/2024]
Abstract
Myocardial infarction occurs rapidly, and thus the rapid detection of cTnI levels is the key to its diagnosis. Most current assays take 10-30 min. In this study, we developed a method for accurately measuring cardiac troponin I (cTnI) levels in human sera with amplified luminescence neighborhood homogeneous assay (AlphaLISA). The method involves coupling two cTnI antibodies targeting different epitopes to the surface of carboxylated donor and acceptor beads. The final signal values were detected by the double-antibody sandwich method, and the best reaction conditions were obtained by optimizing the experimental conditions. The sensitivity, specificity, accuracy, and precision of the method were evaluated. Results showed that the method requires only 3 min to produce the results, the detection sensitivity is 27.06 ng L-1, and the measurement range is 34.56-62 500 ng L-1. cTnI-AlphaLISA has an intra-assay precision of 2.18-4.57% (<10%) and an inter-assay precision of 5.60-6.95% (<10%). The relative recovery rates are within reasonable limits. In addition, the serum assay results of the method were compared with chemiluminescence immunoassay, and the results are in agreement with one another (ρ = 0.8803; P < 0.0001). The method is expected to be developed as a routine method, but further studies and evaluations are needed.
Collapse
Affiliation(s)
- Yan Tang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
| | - Fuzhong Chen
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
| | - Wei Lv
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
| | - Zixuan Zhou
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
| | - Yulin Fu
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
| | - Yuan Qin
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
| | - Xueqin Zhao
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
| | - Junhong Wang
- Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
- Liyang People's Hospital, 70 Jianshe West Road, 213300, Liyang, China
| | - Biao Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
| |
Collapse
|
5
|
Lv W, Li Q, Tang Y, Qin Y, Zhou X, Zhao X, Zheng Z, Huang B. AlphaLISA-Based Immunoassay for Detection of Troponin T in Serum of Patients with Acute Myocardial Infarction. J Fluoresc 2024:10.1007/s10895-024-03775-w. [PMID: 38780833 DOI: 10.1007/s10895-024-03775-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 05/14/2024] [Indexed: 05/25/2024]
Abstract
Survival and prognosis of patients with acute myocardial infarction (AMI) are highly dependent on rapid and accurate diagnosis of myocardial damage. Troponin T is the primary diagnostic biomarker and is widely used in clinical practice. Amplified luminescent proximity homogeneous assay (AlphaLISA) may provide a solution to rapidly detect a small amount of analyte through molecular interactions between special luminescent donor beads and acceptor bead. Here, a double-antibody sandwich assay was introduced into AlphaLISA for rapid detection for early diagnosis of AMI and disease staging evaluation. The performance of the assay was evaluated. The study found that the cTnT assay has a linear range of 48.66 to 20,000 ng/L with a limit of detection of 48.66 ng/L. In addition, the assay showed no cross-reactivity with other classic biomarkers of myocardial infarction and was highly reproducible with intra- and inter-batch coefficients of variation of less than 10%, notably, only 3 min was taken, which is particularly suitable for clinical diagnosis. These results suggest that our method can be conveniently applied in the clinic to determine the severity of the patient's condition.
Collapse
Affiliation(s)
- Wei Lv
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China
| | - Qian Li
- Zhejiang Provincial People's Hospital, People's Hospital of Hangzhou Medical College, Hangzhou, China
| | - Yan Tang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China
| | - Yuan Qin
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China
| | - Xiumei Zhou
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China
| | - Xueqin Zhao
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China.
| | - Zhencang Zheng
- Taizhou Central Hospital(Taizhou University Hospital), Taizhou, 318000, China.
| | - Biao Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310016, China.
| |
Collapse
|
6
|
Fu Y, Sun D, Qin Y, Zheng T, Zhou Z, Zhou X, Zhao X, Xu Y, Huang B. Development and application of an amplified luminescent proximity homogeneous assay-linked immunosorbent assay for the accurate quantification of kidney injury molecule-1. Front Mol Biosci 2024; 10:1280681. [PMID: 38304229 PMCID: PMC10832993 DOI: 10.3389/fmolb.2023.1280681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 12/06/2023] [Indexed: 02/03/2024] Open
Abstract
Background: Kidney injury molecule-1 (Kim-1), a specific marker of kidney injury, is usually not expressed in normal kidneys or at very low levels but is highly expressed in injured renal tubular epithelial cells until the damaged cells recover completely. Therefore, we aimed to develop an efficient and highly sensitive assay to accurately quantify Kim-1 levels in human serum and urine. Methods: In this study, a novel immunoassay was developed and named amplified luminescent proximity homogeneous assay-linked immunosorbent assay (AlphaLISA). Anti-Kim-1 antibodies can be directly coupled to carboxyl-modified donor and acceptor beads for the rapid detection of Kim-1 by double-antibody sandwich method. Serum and urine samples for Kim-1 measurements were obtained from 129 patients with nephropathy and 17 healthy individuals. Results: The linear range of Kim-1 detected by AlphaLISA was 3.83-5000 pg/mL, the coefficients of variation of intra-assay and inter-assay batches were 3.36%-4.71% and 5.61%-11.84%, respectively, and the recovery rate was 92.31%-99.58%. No cross reactions with neutrophil gelatinase-associated lipocalin, liver-type fatty acid binding protein, and matrix metalloproteinase-3 were observed. A good correlation (R 2 = 0.9086) was found between the findings of Kim-1-TRFIA and Kim-AlphaLISA for the same set of samples. In clinical trials, both serum and urine Kim-1 levels were significantly higher in patients with nephropathy than in healthy individuals, especially in patients with acute kidney injury. Furthermore, serum Kim-1 was superior to urinary Kim-1 in distinguishing between patients with nephropathy and healthy individuals. Conclusion: The developed Kim-1-AlphaLISA is highly efficient, precise, and sensitive, and it is suitable for the rapid detection of patients with acute kidney injury.
Collapse
Affiliation(s)
- Yulin Fu
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Danqin Sun
- Department of Nephrology, Jiangnan University Medicine Center, Wuxi, China
| | - Yuan Qin
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Tianyu Zheng
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Zixuan Zhou
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Xiumei Zhou
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Xueqin Zhao
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Yan Xu
- Department of Nephrology, Suzhou Ninth People’s Hospital, Suzhou Ninth Hospital Affiliated to Soochow University, Suzhou, China
| | - Biao Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| |
Collapse
|
7
|
Yang X, Zheng L, Sun Y, Tan X, Zhang B, Li X, Li H. Quantitative Detection of House Dust Mites-Specific IgE by Light-Initiated Chemiluminescence Assay. Lab Med 2024; 55:27-33. [PMID: 37052524 DOI: 10.1093/labmed/lmad024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/14/2023] Open
Abstract
OBJECTIVE To establish a new method for quantitative detection of house dust mite (HDM)-sIgE based on light-initiated chemiluminescence assay (LiCA). METHODS The assay was established after optimizing the reaction conditions, and the assay performance was evaluated according to the clinical guidelines. Further, the results of LiCA were compared with those from the ELISA and ImmunoCAP methods. RESULTS Coefficients of variation for repeatability ranged from 4.22% to 7.69%, and intermediate precision from 8.38% to 10.34%. The limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) were 0.066 kUA/L, 0.165 kUA/L, and 0.171 kUA/L, respectively. The coefficient of correlation (r) between the results of LiCA and ELISA was 0.9263, and the r between the results of LiCA and ImmunoCAP was 0.8870. CONCLUSIONS A HDM-sIgE quantitation assay based on LiCA was established, which could be used as a new reliable analytical tool for the determination of HDM-sIgE.
Collapse
Affiliation(s)
- Xiaohui Yang
- Department of Clinical Immunology, School of Medical Laboratory, Tianjin Medical University, Tianjin, China
| | - Lisheng Zheng
- Department of Clinical Immunology, School of Medical Laboratory, Tianjin Medical University, Tianjin, China
| | - Yuanmin Sun
- Department of Clinical Immunology, School of Medical Laboratory, Tianjin Medical University, Tianjin, China
| | - Xin Tan
- Department of Clinical Immunology, School of Medical Laboratory, Tianjin Medical University, Tianjin, China
| | - Bei Zhang
- Department of Clinical Immunology, School of Medical Laboratory, Tianjin Medical University, Tianjin, China
| | - Xue Li
- Department of Clinical Immunology, School of Medical Laboratory, Tianjin Medical University, Tianjin, China
| | - Huiqiang Li
- Department of Clinical Immunology, School of Medical Laboratory, Tianjin Medical University, Tianjin, China
| |
Collapse
|
8
|
Qin Y, Li J, Kuang J, Shen S, Zhou X, Zhao X, Huang B, Han B. Okadaic Acid Detection through a Rapid and Sensitive Amplified Luminescent Proximity Homogeneous Assay. Toxins (Basel) 2023; 15:501. [PMID: 37624258 PMCID: PMC10467062 DOI: 10.3390/toxins15080501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 08/02/2023] [Accepted: 08/12/2023] [Indexed: 08/26/2023] Open
Abstract
Okadaic acid (OA), a marine biotoxin produced by microalgae, poses a significant threat to mariculture, seafood safety, and human health. The establishment of a novel, highly sensitive detection method for OA would have significant practical and scientific implications. Therefore, the purpose of this study was to develop an innovative approach for OA detection. A competitive amplified luminescent proximity homogeneous assay (AlphaLISA) was developed using the principle of specific antigen-antibody binding based on the energy transfer between chemiluminescent microspheres. The method was non-washable, sensitive, and rapid, which could detect 2 × 10-2-200 ng/mL of OA within 15 min, and the detection limit was 4.55 × 10-3 ng/mL. The average intra- and inter-assay coefficients of variation were 2.54% and 6.26%, respectively. Detection of the actual sample results exhibited a good correlation with high-performance liquid chromatography. In conclusion, a simple, rapid, sensitive, and accurate AlphaLISA method was established for detecting OA and is expected to significantly contribute to marine biotoxin research.
Collapse
Affiliation(s)
- Yuan Qin
- Correspondence: (Y.Q.); (B.H.); (B.H.)
| | | | | | | | | | | | - Biao Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310018, China; (J.L.); (J.K.); (S.S.); (X.Z.); (X.Z.)
| | - Bingnan Han
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, 310018, China; (J.L.); (J.K.); (S.S.); (X.Z.); (X.Z.)
| |
Collapse
|