1
|
Teixeira J, Sousa G, Azevedo R, Almeida A, Delerue-Matos C, Wang X, Santos-Silva A, Rodrigues F, Oliveira M. Characterization of Wildland Firefighters' Exposure to Coarse, Fine, and Ultrafine Particles; Polycyclic Aromatic Hydrocarbons; and Metal(loid)s, and Estimation of Associated Health Risks. TOXICS 2024; 12:422. [PMID: 38922102 PMCID: PMC11209316 DOI: 10.3390/toxics12060422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 06/06/2024] [Accepted: 06/07/2024] [Indexed: 06/27/2024]
Abstract
Firefighters' occupational activity causes cancer, and the characterization of exposure during firefighting activities remains limited. This work characterizes, for the first time, firefighters' exposure to (coarse/fine/ultrafine) particulate matter (PM) bound polycyclic aromatic hydrocarbons (PAHs) and metal(loid)s during prescribed fires, Fire 1 and Fire 2 (210 min). An impactor collected 14 PM fractions, the PM levels were determined by gravimetry, and the PM-bound PAHs and metal(loid)s were determined by chromatographic and spectroscopic methodologies, respectively. Firefighters were exposed to a total PM level of 1408.3 and 342.5 µg/m3 in Fire 1 and Fire 2, respectively; fine/ultrafine PM represented more than 90% of total PM. Total PM-bound PAHs (3260.2 ng/m3 in Fire 1; 412.1 ng/m3 in Fire 2) and metal(loid)s (660.8 ng/m3 versus 262.2 ng/m3), distributed between fine/ultrafine PM, contained 4.57-24.5% and 11.7-12.6% of (possible/probable) carcinogenic PAHs and metal(loid)s, respectively. Firefighters' exposure to PM, PAHs, and metal(loid)s were below available occupational limits. The estimated carcinogenic risks associated with the inhalation of PM-bound PAHs (3.78 × 10-9 - 1.74 × 10-6) and metal(loid)s (1.50 × 10-2 - 2.37 × 10-2) were, respectively, below and 150-237 times higher than the acceptable risk level defined by the USEPA during 210 min of firefighting activity and assuming a 40-year career as a firefighter. Additional studies need to (1) explore exposure to (coarse/fine/ultrafine) PM, (2) assess health risks, (3) identify intervention needs, and (4) support regulatory agencies recommending mitigation procedures to reduce the impact of fire effluents on firefighters.
Collapse
Affiliation(s)
- Joana Teixeira
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
- REQUIMTE/UCIBIO, Unidade de Ciências Biomoleculares Aplicadas, Departamento de Ciências Biológicas, Faculdade de Farmácia, Universidade do Porto, R. Jorge de Viterbo Ferreira 228, 4050-313 Porto, Portugal
| | - Gabriel Sousa
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| | - Rui Azevedo
- REQUIMTE/LAQV, Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, R. Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal
| | - Agostinho Almeida
- REQUIMTE/LAQV, Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, R. Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal
| | - Cristina Delerue-Matos
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| | - Xianyu Wang
- QAEHS, Queensland Alliance for Environmental Health Sciences, The University of Queensland, 20 Cornwall Street, Woolloongabba, QLD 4102, Australia
| | - Alice Santos-Silva
- REQUIMTE/UCIBIO, Unidade de Ciências Biomoleculares Aplicadas, Departamento de Ciências Biológicas, Faculdade de Farmácia, Universidade do Porto, R. Jorge de Viterbo Ferreira 228, 4050-313 Porto, Portugal
- Laboratório Associado i4HB, Instituto para a Saúde e a Bioeconomia, Faculdade de Farmácia, Universidade do Porto, R. Jorge de Viterbo Ferreira 228, 4050-313 Porto, Portugal
| | - Francisca Rodrigues
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| | - Marta Oliveira
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| |
Collapse
|
2
|
Chen S, Zhang Y, Chen H, Zheng W, Hu X, Mao L, Guo X, Lian H. Surface property and in vitro toxicity effect of insoluble particles given by protein corona: Implication for PM cytotoxicity assessment. ECO-ENVIRONMENT & HEALTH 2024; 3:137-144. [PMID: 38638169 PMCID: PMC11021833 DOI: 10.1016/j.eehl.2024.01.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 01/18/2024] [Accepted: 01/25/2024] [Indexed: 04/20/2024]
Abstract
In vitro toxicological assessment helps explore key fractions of particulate matter (PM) in association with the toxic mechanism. Previous studies mainly discussed the toxicity effects of the water-soluble and organic-soluble fractions of PM. However, the toxicity of insoluble fractions is relatively poorly understood, and the adsorption of proteins is rarely considered. In this work, the formation of protein corona on the surface of insoluble particles during incubation in a culture medium was investigated. It was found that highly abundant proteins in fetal bovine serum were the main components of the protein corona. The adsorbed proteins increased the dispersion stability of insoluble particles. Meanwhile, the leaching concentrations of some metal elements (e.g., Cu, Zn, and Pb) from PM increased in the presence of proteins. The toxicity effects and potential mechanisms of the PM insoluble particle-protein corona complex on macrophage cells RAW264.7 were discussed. The results revealed that the PM insoluble particle-protein corona complex could influence the phagosome pathway in RAW264.7 cells. Thus, it promoted the intracellular reactive oxygen species generation and induced a greater degree of cell differentiation, significantly altering cell morphology. Consequently, this work sheds new light on the combination of insoluble particles and protein corona in terms of PM cytotoxicity assessment.
Collapse
Affiliation(s)
- Sisi Chen
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry & Chemical Engineering and Center of Materials Analysis, Nanjing University, Nanjing 210023, China
| | - Yexuan Zhang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry & Chemical Engineering and Center of Materials Analysis, Nanjing University, Nanjing 210023, China
| | - Hongjuan Chen
- State Key Laboratory of Pharmaceutical Biotechnology, School of Life Science, Nanjing University, Nanjing 210023, China
| | - Weijuan Zheng
- State Key Laboratory of Pharmaceutical Biotechnology, School of Life Science, Nanjing University, Nanjing 210023, China
| | - Xin Hu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry & Chemical Engineering and Center of Materials Analysis, Nanjing University, Nanjing 210023, China
| | - Li Mao
- Ministry of Education (MOE) Key Laboratory of Modern Toxicology, School of Public Health, Nanjing Medical University, Nanjing 211166, China
| | - Xuewen Guo
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry & Chemical Engineering and Center of Materials Analysis, Nanjing University, Nanjing 210023, China
| | - Hongzhen Lian
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry & Chemical Engineering and Center of Materials Analysis, Nanjing University, Nanjing 210023, China
| |
Collapse
|
3
|
Teixeira J, Sousa G, Morais S, Delerue-Matos C, Oliveira M. Assessment of coarse, fine, and ultrafine particulate matter at different microenvironments of fire stations. CHEMOSPHERE 2023:139005. [PMID: 37245598 DOI: 10.1016/j.chemosphere.2023.139005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 05/17/2023] [Accepted: 05/20/2023] [Indexed: 05/30/2023]
Abstract
The concentrations of respirable particulate matter (PM) and the impact on indoor air quality in occupational settings remains poorly characterized. This study assesses, for the first time, the cumulative and non-cumulative concentrations of 14 fractions of coarse (3.65-9.88 μm), fine (0.156-2.47 μm), and ultrafine (0.015-0.095 μm) PM inside the garage of heavy vehicles, firefighting personal protective equipment' storage room, bar, and a common area of seven Portuguese fire stations. Sampling campaigns were performed during a regular work week at the fire stations. Levels of daily total cumulative PM ranged from 277.4 to 413.2 μg/m3 (maximum values of 811.4 μg/m3), with the bar (370.1 μg/m3) and the PPE' storage room (361.3 μg/m3) presenting slightly increased levels (p > 0.05) than the common area (324.8 μg/m3) and the garage (339.4 μg/m3). The location of the sampling site, the proximity to local industries and commercial activities, the layout of the building, the heating system used, and indoor sources influenced the PM concentrations. Fine (193.8-301.0 μg/m3) and ultrafine (41.3-78.2 μg/m3) particles were predominant in the microenvironments of all fire stations and accounted for 71.5% and 17.8% of daily total cumulative levels, respectively; coarse particles (23.3-47.1 μg/m3) represented 10.7% of total PM. The permissible exposure limit (5.0 mg/m3) defined by the Occupational Safety and Health Organization for respirable dust was not overcome in the evaluated fire stations. Results suggest firefighters' regular exposure to fine and ultrafine PM inside fire stations which will contribute to cardiorespiratory health burden. Further studies are needed to characterize firefighters' exposure to fine and ultrafine PM inside fire stations, identify main emission sources, and evaluate the contribution of exposures at fire stations to firefighters' occupational health risks.
Collapse
Affiliation(s)
- Joana Teixeira
- REQUIMTE/LAQV, Instituto Superior de Engenharia Do Porto, Instituto Politécnico Do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015, Porto, Portugal
| | - Gabriel Sousa
- REQUIMTE/LAQV, Instituto Superior de Engenharia Do Porto, Instituto Politécnico Do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015, Porto, Portugal
| | - Simone Morais
- REQUIMTE/LAQV, Instituto Superior de Engenharia Do Porto, Instituto Politécnico Do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015, Porto, Portugal
| | - Cristina Delerue-Matos
- REQUIMTE/LAQV, Instituto Superior de Engenharia Do Porto, Instituto Politécnico Do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015, Porto, Portugal
| | - Marta Oliveira
- REQUIMTE/LAQV, Instituto Superior de Engenharia Do Porto, Instituto Politécnico Do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015, Porto, Portugal.
| |
Collapse
|
4
|
Bessa MJ, Sarmento B, Oliveira M, Rodrigues F. In vitro data for fire pollutants: contribution of studies using human cell models towards firefighters' occupational. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART B, CRITICAL REVIEWS 2023; 26:238-255. [PMID: 36883725 DOI: 10.1080/10937404.2023.2187909] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Firefighters are the principal line of defense against fires, being at elevated risk of exposure to health-relevant pollutants released during fires and burning processes. Although many biomonitoring studies exist, only a limited number of human in vitro investigations in fire risk assessment are currently available. In vitro studies stand out as valuable tools to assess the toxicity mechanisms involved following exposure to fire pollutants at a cellular level. The aim of the present review was to contextualize existing in vitro studies using human cell models exposed to chemicals emitted from fire emissions and wood smoke and discuss the implications of the observed toxic outcomes on adverse health effects detected in firefighters. Most of the reported in vitro investigations focused on monocultures respiratory models and exposure to particulate matter (PM) extracts collected from fire effluents. Overall, (1) a decrease in cellular viability, (2) enhanced oxidative stress, (3) increased pro-inflammatory cytokines levels and (4) elevated cell death frequencies were noted. However, limited information remains regarding the toxicity mechanisms initiated by firefighting activities. Hence, more studies employing advanced in vitro models and exposure systems using human cell lines are urgently needed taking into consideration different routes of exposure and health-related pollutants released from fires. Data are needed to establish and define firefighters' occupational exposure limits and to propose mitigation strategies to promote beneficial human health.
Collapse
Affiliation(s)
- Maria João Bessa
- UNIPRO - Unidade de Investigação em Patologia e Reabilitação Oral, Instituto Universitário de Ciências da Saúde (IUCS), CESPU, Gandra, Portugal
| | - Bruno Sarmento
- UNIPRO - Unidade de Investigação em Patologia e Reabilitação Oral, Instituto Universitário de Ciências da Saúde (IUCS), CESPU, Gandra, Portugal
- i3S - Institute for Research and Innovation in Health, University of Porto, Porto, Portugal
- INEB - Institute of Biomedical Engineering, University of Porto, Porto, Portugal
| | - Marta Oliveira
- REQUIMTE/LAQV, ISEP, Polytechnique of Porto, Porto, Portugal
| | | |
Collapse
|