1
|
Yu S, You J, Shi X, Zou X, Lu Z, Wang Y, Tan J, Sun Z, Li Z, Ji Z, Song C. Rapid Analysis of Estrogens in Meat Samples by High Performance Liquid Chromatography with Fluorescence Detection. J Fluoresc 2024; 34:425-436. [PMID: 37284963 DOI: 10.1007/s10895-023-03248-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Accepted: 04/18/2023] [Indexed: 06/08/2023]
Abstract
A novel reagent named 4-(N-methyl-1,3-dioxo-benzoisoquinolin-6-yl-oxy)benzene sulfonyl chloride (MBIOBS-Cl) for the determination of estrogens in food samples by high-performance liquid chromatography (HPLC) with fluorescence detection has been developed. Estrogens could be easily labeled by MBIOBS-Cl in Na2CO3-NaHCO3 buffer solution at pH 10.0. The complete labeling reaction for estrogens could be accomplished within five minutes, the corresponding derivatives exhibited strong fluorescence with the maximum excitation and emission wavelengths at 249 nm and 443 nm, respectively. The derivatization conditions, such as the molar ratio of reagent to estrogens, derivatization time, pH, temperature, and buffers were optimized. Derivatives were sufficiently stable to be efficiently analyzed by HPLC with a reversed-phase Agilent ZORBAX 300SB-C18 column with a good baseline resolution. Excellent linear correlations were obtained for all estrogen derivatives with correlation coefficients greater than 0.9998. Ultrasonic-Assisted extraction was used to optimize the extraction of estrogens from meat samples with a recovery higher than 82%. The detection limits (LOD, S/N = 3) of the method ranged from 0.95 to 3.3 μg· kg-1. The established method, which is fast, simple, inexpensive, and environment friendly, can be successfully applied for the detection of four steroidal estrogens from meat samples with little matrix interference.
Collapse
Affiliation(s)
- Shuiqiang Yu
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, People's Republic of China
| | - Jinmao You
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, People's Republic of China.
- College of Chemistry and Chemical Engineering, Shaoxing University, Shaoxing, 312000, People's Republic of China.
| | - Xinxin Shi
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, People's Republic of China
| | - Xiaocong Zou
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, People's Republic of China
| | - Zhihao Lu
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, People's Republic of China
| | - Yu Wang
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, People's Republic of China
| | - Jiangkun Tan
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, People's Republic of China
| | - Zhiwei Sun
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, People's Republic of China
| | - Zan Li
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, People's Republic of China
| | - Zhongyin Ji
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, People's Republic of China
| | - Cuihua Song
- Key Laboratory of Life-Organic Analysis of Shandong Province, School of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, People's Republic of China
| |
Collapse
|
2
|
Chang R, Wang X, Li Y, Zhang S. Pyridinium and ammonium stable isotope labeling agents and their performance in the analysis of alkylamines in food and food packaging materials. Food Chem 2023; 408:135240. [PMID: 36549157 DOI: 10.1016/j.foodchem.2022.135240] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 12/04/2022] [Accepted: 12/15/2022] [Indexed: 12/23/2022]
Abstract
Two pairs of stable isotope labeling (SIL) agents, (4-carboxyphenyl)trimethylammonium iodide (d0-CPTA) and its deuterated counterpart d3-CPTA, 1-methyl-nicotinamide iodide (d0-MNA) and its deuterated counterpart d3-MNA, were designed and synthesized. Their mass spectrometry (MS) sensitivity enhancement effect was studied and compared with commercial dansyl chloride to provide inspiration for labeling agent design. CPTA with quaternary ammonium group showed much higher MS sensitivity enhancement effect and was applied to the SIL analysis of alkylamines in food and food packaging materials. The matrix effect was minimized due to the SIL strategy and the permanent charge of the CPTA. The limits of detection (LODs) were in the range of 2.9-5.1 ng/L, and the limits of quantitation (LOQs) were in the range of 9.6-16.8 ng/L. The recoveries ranged from 91.2 % to 97.1 % with relative standard deviations of less than 6.6 %, and the matrix effect ranged from -1.8 % to -4.9 %.
Collapse
Affiliation(s)
- Rui Chang
- Shandong Province Key Laboratory of Life-Organic Analysis, Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, School of Chemistry and Chemical Engineering, Qufu Normal University, PR China
| | - Xueting Wang
- Shandong Province Key Laboratory of Life-Organic Analysis, Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, School of Chemistry and Chemical Engineering, Qufu Normal University, PR China
| | - Yanxin Li
- Shandong Province Key Laboratory of Life-Organic Analysis, Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, School of Chemistry and Chemical Engineering, Qufu Normal University, PR China
| | - Shijuan Zhang
- Shandong Province Key Laboratory of Life-Organic Analysis, Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, School of Chemistry and Chemical Engineering, Qufu Normal University, PR China.
| |
Collapse
|
3
|
Atapattu SN, Rosenfeld JM. Analytical derivatizations in environmental analysis. J Chromatogr A 2022; 1678:463348. [PMID: 35901668 DOI: 10.1016/j.chroma.2022.463348] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 07/13/2022] [Accepted: 07/13/2022] [Indexed: 10/17/2022]
Abstract
Analytical derivatization is a technique that alters the structure of an analyte and produces a product more suitable for analysis. While this process can be time-consuming and add reagents to the procedure, it can also facilitate the isolation of the analyte(s), enhance analytes' stability, improve separation and sensitivity, and reduce matrix interferences. Since derivatization is a functional group analysis, it improves selectivity by separating reactive from neutral compounds during sample preparation. This technique introduces detector-orientated tags into analytes that lack suitable physicochemical properties for detection at low concentrations. Notably, many regulatory bodies, especially those in the environmental field, require these characteristics in analytical methods. This review focuses on note-worthy analytical derivatization methods employed in environmental analyses with functional groups, phenol, carboxylic acid, aldehyde, ketone, and thiol in aqueous, soil, and atmospheric sample matrices. Both advantages and disadvantages of analytical derivatization techniques are discussed. In addition, we discuss the future directions of analytical derivatization methods in environmental analysis and the potential challenges.
Collapse
Affiliation(s)
| | - Jack M Rosenfeld
- Department of Pathology and Molecular Medicine, McMaster University, Hamilton, ON L8S 4K1, Canada
| |
Collapse
|
4
|
Li Y, Ma C, You J, Zhang S. Stable isotope labeling method with sensitive identification and accurate quantitation function for aldehydes in fried foods. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107238] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
5
|
Chang R, Ma C, Yu C, Zhang Q, Li Y, You J, Zhang S. Analysis of estrogens in milk samples using ionic liquid-modified covalent organic framework and stable isotope labeling technique. Eur Food Res Technol 2021. [DOI: 10.1007/s00217-021-03830-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
6
|
Zaikin VG, Borisov RS. Options of the Main Derivatization Approaches for Analytical ESI and MALDI Mass Spectrometry. Crit Rev Anal Chem 2021; 52:1287-1342. [PMID: 33557614 DOI: 10.1080/10408347.2021.1873100] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The inclusion of preliminary chemical labeling (derivatization) in the analysis process by such powerful and widespread methods as electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is a popular and widely used methodological approach. This is due to the need to remove some fundamental limitations inherent in these powerful analytic methods. Although a number of special reviews has been published discussing the utilization of derivatization approaches, the purpose of the present critical review is to comprehensively summarize, characterize and evaluate most of the previously developed and practically applied, as well as recently proposed representative derivatization reagents for ESI-MS and MALDI-MS platforms in their mostly sensitive positive ion mode and frequently hyphenated with separation techniques. The review is focused on the use of preliminary chemical labeling to facilitate the detection, identification, structure elucidation, quantification, profiling or MS imaging of compounds within complex matrices. Two main derivatization approaches, namely the introduction of permanent charge-fixed or highly proton affinitive residues into analytes are critically evaluated. In situ charge-generation, charge-switch and charge-transfer derivatizations are considered separately. The potential of using reactive matrices in MALDI-MS and chemical labeling in MS-based omics sciences is given.
Collapse
Affiliation(s)
- Vladimir G Zaikin
- A.V. Topchiev Institute of Petrochemical Synthesis, Russian Academy of Sciences, Moscow, Russian Federation
| | - Roman S Borisov
- A.V. Topchiev Institute of Petrochemical Synthesis, Russian Academy of Sciences, Moscow, Russian Federation
| |
Collapse
|
7
|
Preparation of sheet-like covalent organic frameworks and their application for efficient preconcentration of 4-(tert-octyl)-phenol and 4-nonylphenol in textiles. J Chromatogr A 2020; 1635:461765. [PMID: 33285418 DOI: 10.1016/j.chroma.2020.461765] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 11/20/2020] [Accepted: 11/24/2020] [Indexed: 11/24/2022]
Abstract
In the design of highly ordered (covalent organic frameworks) COFs with "ordered domains size and orientation" construction in a well-defined arrangement, the molecular monomers are the key factors. Here, the effect of molecular monomers on the construction of COFs has been studied, and two kinds of molecular monomers, i.e., ethanediamine (flexible amine ligand) and 4,4'-diaminobiphenyl (rigid amine ligand) have been used for developing sheet-like COFs-I and sheet-like COFs-II, respectively. Furthermore, they have been evaluated in the dispersive solid phase extraction (dSPE) procedure for textiles prior to the analysis of alkylphenol by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). The results showed that, the optimal usage amount of sheet-like COFs-II used in the dSPE procedure was less than that of sheet-like COFs-I, which may be explained by much higher adsorption capacity of sheet-like COFs via hydrogen-bonding and π-π stacking interactions. Rectilinear calibration graphs were obtained for 4-(tert-octyl)-phenol (4-tOP) and 4-nonylphenol (4-NP) in the range 0.2-20 µg/kg with determination coefficient (r2) higher than 0.9990, and the limits of detection (LODs) of 4-tOP and 4-NP were 0.039 µg/kg and 0.048 µg/kg, respectively. The developed method has been successfully applied to analysis of 50 textile samples, in which 4-tOP and 4-NP were found in six samples with concentrations in the range of 1.6 μg/kg-20.9 μg/kg.
Collapse
|
8
|
Ma C, Zhang S, Wu X, You J. Permanently Positively Charged Stable Isotope Labeling Agents and Its Application in the Accurate Quantitation of Alkylphenols Migrated from Plastics to Edible Oils. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2020; 68:9024-9031. [PMID: 32697581 DOI: 10.1021/acs.jafc.0c03413] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A new permanently positively charged stable isotope labeling (SIL) agent pair, 4-(((2,5-dioxopyrrolidin-1-yl)oxy)carbonyl)-N,N,N-trimethylbenzenaminium iodide(DPTBA) and its deuterated counterpart d3-DPTBA, was designed and synthesized. The SIL agents were applied to the liquid chromatography-tandem mass spectrometry analysis of alkylphenols. Light labeled standards and heavy labeled samples were mixed and analyzed simultaneously. Matrix effect which mainly occurred during the ionization process was minimized because of the identical ionization processes between samples and standards. Meanwhile, derivatization made alkylphenols be positively charged, and thus the sensitivity was enhanced. The limits of detection were in the range of 1.5-1.8 ng/L, and the limits of quantitation were in the range of 4.8-6.1 ng/L. The developed method was applied to analyze alkylphenols migrated from plastics to edible oils. The recoveries for all analytes were in the range of 88.6-95.3%, while the matrix effects for all analytes were in the range of 96.2-99.6%.
Collapse
Affiliation(s)
- Chong Ma
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
- Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, Qufu Normal University, Qufu, PR China
| | - Shijuan Zhang
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
- Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, Qufu Normal University, Qufu, PR China
| | - Xia Wu
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
- Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, Qufu Normal University, Qufu, PR China
| | - Jinmao You
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
- Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, Qufu Normal University, Qufu, PR China
| |
Collapse
|
9
|
Wu C, Dong F, Mei X, Ning J, She D. Isotope-labeled internal standards and grouping scheme for determination of neonicotinoid insecticides and their metabolites in fruits, vegetables and cereals – A compensation of matrix effects. Food Chem 2020; 311:125871. [DOI: 10.1016/j.foodchem.2019.125871] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Revised: 10/18/2019] [Accepted: 11/05/2019] [Indexed: 10/25/2022]
|
10
|
Current trends in isotope‐coded derivatization liquid chromatographic‐mass spectrometric analyses with special emphasis on their biomedical application. Biomed Chromatogr 2020; 34:e4756. [DOI: 10.1002/bmc.4756] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Revised: 11/13/2019] [Accepted: 11/18/2019] [Indexed: 12/17/2022]
|
11
|
Phipps WS, Crossley E, Boriack R, Jones PM, Patel K. Quantitative amino acid analysis by liquid chromatography-tandem mass spectrometry using low cost derivatization and an automated liquid handler. JIMD Rep 2019; 51:62-69. [PMID: 32071840 PMCID: PMC7012744 DOI: 10.1002/jmd2.12080] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 09/11/2019] [Accepted: 09/13/2019] [Indexed: 01/22/2023] Open
Abstract
Amino acid analysis is central to newborn screening and the investigation of inborn errors of metabolism. Ion‐exchange chromatography with ninhydrin derivatization remains the reference method for quantitative amino acid analysis but offers slow chromatography and is susceptible to interference from other co‐eluting compounds. Liquid‐chromatography tandem mass spectrometry (LC‐MS/MS) provides a rapid and highly specific alternative, but sample preparation is frequently laborious and sometimes cost prohibitive. To address these limitations, we validated an LC‐MS/MS method using the aTRAQ Reagents Application Kit with a modified protocol consuming only half reagents. Adequate performance for clinical specimen measurement of 26 amino acids with high clinical relevance was achieved. An automated liquid handler and modified calibration and normalization approaches were used to ensure reproducible assay performance. Linear measurement between 5 and 2000 μM was achieved for most analytes despite use of a small, 10 μl sample size. Overall the method achieved near substantially improved throughput and enabled use of smaller samples volumes for batched analyses of clinical samples.
Collapse
Affiliation(s)
- William S Phipps
- Department of Pathology University of Texas at Southwestern Medical Center Dallas Texas
| | - Eric Crossley
- Chemistry, Metabolic Disease and Mass Spectrometry Laboratories Children's Health Dallas Texas
| | - Richard Boriack
- Chemistry, Metabolic Disease and Mass Spectrometry Laboratories Children's Health Dallas Texas
| | - Patricia M Jones
- Department of Pathology University of Texas at Southwestern Medical Center Dallas Texas.,Chemistry, Metabolic Disease and Mass Spectrometry Laboratories Children's Health Dallas Texas
| | - Khushbu Patel
- Department of Pathology University of Texas at Southwestern Medical Center Dallas Texas.,Chemistry, Metabolic Disease and Mass Spectrometry Laboratories Children's Health Dallas Texas
| |
Collapse
|
12
|
Phipps WS, Jones PM, Patel K. Amino and organic acid analysis: Essential tools in the diagnosis of inborn errors of metabolism. Adv Clin Chem 2019; 92:59-103. [PMID: 31472756 DOI: 10.1016/bs.acc.2019.04.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Inborn errors of metabolism (IEMs) are a large class of genetic disorders that result from defects in enzymes involved in energy production and metabolism of nutrients. For every metabolic pathway, there are defects that can occur and potentially result in an IEM. While some defects can go undetected in one's lifetime, some have moderate to severe clinical consequences. In the latter case, the biochemical defect leads to accumulation of metabolites and byproducts that are toxic or interfere with normal biological function. Disorders of amino acid metabolism, organic acid metabolism and the urea cycle comprise a large portion of IEMs. Two essential tools required for the diagnosis of these categories of disorders are amino acid and organic acid profiling. Most all clinical laboratories offering metabolic testing perform amino acid analysis, while organic acid profiling is restricted to more specialized pediatric hospitals and reference laboratories. In this chapter, we will provide an overview of various methodologies employed for amino acid and organic acid profiling as well as specific examples to demonstrate how these techniques are applied in clinical laboratories for the diagnosis of IEMs.
Collapse
Affiliation(s)
- William S Phipps
- Department of Pathology, UT Southwestern Medical Center, Dallas, TX, United States
| | - Patti M Jones
- Department of Pathology, UT Southwestern Medical Center, Dallas, TX, United States
| | - Khushbu Patel
- Department of Pathology, UT Southwestern Medical Center, Dallas, TX, United States.
| |
Collapse
|
13
|
Luo YR, Han J, Yun C, Lynch KL. Azo coupling-based derivatization method for high-sensitivity liquid chromatography-tandem mass spectrometry analysis of tetrahydrocannabinol and other aromatic compounds. J Chromatogr A 2019; 1597:109-118. [PMID: 30910385 DOI: 10.1016/j.chroma.2019.03.022] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Revised: 03/01/2019] [Accepted: 03/14/2019] [Indexed: 10/27/2022]
Abstract
An azo coupling-based derivatization method is reported for high-sensitivity liquid chromatography-tandem mass spectrometry (LC-MS/MS) quantitation of tetrahydrocannabinol (THC) and other aromatic compounds, i.e. phenols and amines. Through the azo coupling of a diazonium to an analyte, it produces a derivatized analyte which has enhanced ionization efficiency and results in high-response fragments in tandem mass spectrometry. The derivatization method was applied to six typical aromatic compounds using three different diazonium salts as derivatization reagents, demonstrating its applicability to a variety of analytes and reagents. The derivatization reaction can be directly carried out in neat samples, and after derivatization the samples can be immediately sent to the LC-MS/MS instrument for analysis. These advantages facilitate a one-step sample preparation procedure that can be completed in less than one hour, allowing for a "derivatize & shoot" lab workflow. The derivatization method was applied to establish an LC-MS/MS assay for the quantitation of THC in human breath samples. The derivatization conditions were studied in this application, including the effects of acidity, organic solvent, and diazonium concentration in the reaction. The THC derivatization assay was validated and achieved a limit of quantitation (LOQ) of 0.50 pg/ml using either of the two regio-isomers of the azo-derivative of THC (THC-DRV). To prove that the derivatization method has compatibility with complex-matrix samples, a THC derivatization assay for serum samples was established, in which the azo coupling reaction was directly carried out in crude protein-precipitated supernatants. An LOQ of 5.0 pg/ml was achieved. In addition, excellent correlation between THC derivatization and non-derivatization assays was found in the analysis of whole blood samples.
Collapse
Affiliation(s)
- Yiqi Ruben Luo
- Department of Laboratory Medicine, University of California, San Francisco, and Zuckerberg San Francisco General Hospital, San Francisco, CA, USA.
| | - Jichun Han
- Applin Biotech Inc., Hangzhou, Zhejiang, China
| | - Cassandra Yun
- Department of Laboratory Medicine, University of California, San Francisco, and Zuckerberg San Francisco General Hospital, San Francisco, CA, USA
| | - Kara L Lynch
- Department of Laboratory Medicine, University of California, San Francisco, and Zuckerberg San Francisco General Hospital, San Francisco, CA, USA
| |
Collapse
|
14
|
New Stable Isotope Labeling Strategy in Quaternary Ammonium–Functionalized Magnetic Nanoparticles for the Analysis of Perfluorocarboxylic Acid in Cod Liver Oil. FOOD ANAL METHOD 2019. [DOI: 10.1007/s12161-019-01516-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
15
|
Bai L, Liu J, Liu Q, Xu T, Liu H, Wu T, Zhang S, Li Y, You J. Surfactant-induced magnetic cationic phenolic resin and its application in the enrichment of the migrants from food contacting materials. J LIQ CHROMATOGR R T 2019. [DOI: 10.1080/10826076.2018.1544147] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Ling Bai
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
| | - Jiamin Liu
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
| | - Qian Liu
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
| | - Ting Xu
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
| | - Hongzhan Liu
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
| | - Ting Wu
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
| | - Shijuan Zhang
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
| | - Yanxin Li
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
| | - Jinmao You
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, PR China
| |
Collapse
|
16
|
A highly sensitive and selective method for determination of phenoxy carboxylic acids from environmental water samples by dispersive solid-phase extraction coupled with ultra high performance liquid chromatography-tandem mass spectrometry. Talanta 2019; 191:313-323. [DOI: 10.1016/j.talanta.2018.08.055] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2017] [Revised: 08/16/2018] [Accepted: 08/20/2018] [Indexed: 11/23/2022]
|
17
|
Determination of Ultraviolet Filters in Domestic Wastewater by LC–MS Coupled with Polydopamine-Based Magnetic Solid-Phase Extraction and Isotope-Coded Derivatization. Chromatographia 2018. [DOI: 10.1007/s10337-018-3650-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
18
|
Cationic gemini surfactant-resorcinol-aldehyde resin and its application in the extraction of endocrine disrupting compounds from food contacting materials. Food Chem 2018; 277:407-413. [PMID: 30502164 DOI: 10.1016/j.foodchem.2018.10.132] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Revised: 10/22/2018] [Accepted: 10/28/2018] [Indexed: 12/26/2022]
Abstract
A new cationic gemini surfactant-resorcinol/formaldehyde resin was designed and synthesized. Cationic gemini surfactant was introduced into the resorcinol/formaldehyde resin for the first time and led to the retention of negatively charged endocrine disrupting compounds (EDCs) through electrostatic interactions, hydrogen bonding and π-π interactions. The synthesized material showed good performance in the dispersive micro-solid phase extraction (D-μ-SPE) of EDCs such as alkylphenol and phenoxy acid herbicides from food packaging migrants. Extraction parameters such as pH, adsorbent dose, extraction time and salting out effect were optimized. The limits of detections were in the range of 0.5-0.8 ng/mL, and the recoveries were in the range of 90-100%. The developed method was applied to the analysis of EDCs from food contacting materials migrants with pentachlorophenol, 2,4-dichlorophenoxyacetic acid and bisphenol A detected in the concentration range of 0.2-1.2 mg/kg. It also showed great potential in the D-μ-SPE of other compounds with negative charge or high hydrophobicity.
Collapse
|
19
|
Quaternary ammonium-functionalized MCM-48 mesoporous silica as a sorbent for the dispersive solid-phase extraction of endocrine disrupting compounds in water. J Chromatogr A 2018; 1557:1-8. [DOI: 10.1016/j.chroma.2018.05.011] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 05/02/2018] [Accepted: 05/06/2018] [Indexed: 12/19/2022]
|
20
|
Pérez-Fernández V, Mainero Rocca L, Tomai P, Fanali S, Gentili A. Recent advancements and future trends in environmental analysis: Sample preparation, liquid chromatography and mass spectrometry. Anal Chim Acta 2017; 983:9-41. [DOI: 10.1016/j.aca.2017.06.029] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2017] [Revised: 05/30/2017] [Accepted: 06/01/2017] [Indexed: 02/06/2023]
|
21
|
Wei N, Zheng Z, Wang Y, Tao Y, Shao Y, Zhu S, You J, Zhao XE. Rapid and sensitive determination of multiple endocrine-disrupting chemicals by ultrasound-assisted in situ derivatization dispersive liquid-liquid microextraction coupled with ultra-high-performance liquid chromatography/tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2017; 31:937-950. [PMID: 28370680 DOI: 10.1002/rcm.7865] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Revised: 12/28/2016] [Accepted: 03/25/2017] [Indexed: 06/07/2023]
Abstract
RATIONALE Endocrine-disrupting chemicals (EDCs) in environment samples and food stuffs are an increasing serious public health issue due to their potency to interfere and deregulate several aspects of the endocrine system. Because of their extremely low abundance, it remains a challenging task to develop a sensitive detection method. METHODS 4'-Carbonyl chloride rosamine (CCR) was used as a derivatization reagent for EDCs for the first time. A new ultrasound-assisted in situ derivatization/dispersive liquid-liquid microextraction (UA-DLLME with in situ derivatization) method for multiple EDCs including five estrogens, two alkylphenols, eight bisphenols, seven parabens and triclosan coupled with ultra-high-performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) has been developed and validated. RESULTS The ionization efficiency of EDCs was greatly enhanced through the introduction of a permanent charged moiety of CCR into the derivatives during electrospray ionization (ESI)-MS analysis. The main variables potentially affecting the UA-DLLME with in situ derivatization process are optimized. The recoveries and matrix effects of 23 EDCs for the spiking samples were in the range of 83.0-116.0% and 85.8-114.6%, respectively. Good method reproducibility was achieved. CONCLUSIONS The limits of detection (LODs) for 23 EDCs were 0.05-0.40 ng/L and 0.03-0.25 ng/g (dry weight, d.w.) for environment samples and food stuffs, respectively. The proposed method has been demonstrated to be suitable for simultaneous determination of multiple EDCs in real samples with high sensitivity, speediness, and good sample clean-up ability. Copyright © 2017 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Na Wei
- Shandong Provincial Key Laboratory of Life-Organic Analysis & Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, Shandong, P.R. China
| | - Zhenjia Zheng
- College of Food Science and Engineering, Shandong Agricultural University, 61 Daizong Street, Taian, 271018, Shandong, P.R. China
| | - Yuhua Wang
- Shandong Provincial Key Laboratory of Life-Organic Analysis & Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, Shandong, P.R. China
| | - Yanduo Tao
- Key Laboratory of Tibetan Medicine Research, Northwest Institute of Plateau Biology, Chinese Academy of Science, Xining, 810001, Qinghai, P.R. China
| | - Yun Shao
- Key Laboratory of Tibetan Medicine Research, Northwest Institute of Plateau Biology, Chinese Academy of Science, Xining, 810001, Qinghai, P.R. China
| | - Shuyun Zhu
- Shandong Provincial Key Laboratory of Life-Organic Analysis & Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, Shandong, P.R. China
| | - Jinmao You
- Shandong Provincial Key Laboratory of Life-Organic Analysis & Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, Shandong, P.R. China
- Key Laboratory of Tibetan Medicine Research, Northwest Institute of Plateau Biology, Chinese Academy of Science, Xining, 810001, Qinghai, P.R. China
| | - Xian-En Zhao
- Shandong Provincial Key Laboratory of Life-Organic Analysis & Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, Shandong, P.R. China
| |
Collapse
|
22
|
Zheng L, Zhao XE, Zhu S, Tao Y, Ji W, Geng Y, Wang X, Chen G, You J. A new combined method of stable isotope-labeling derivatization-ultrasound-assisted dispersive liquid–liquid microextraction for the determination of neurotransmitters in rat brain microdialysates by ultra high performance liquid chromatography tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1054:64-72. [DOI: 10.1016/j.jchromb.2017.03.039] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2017] [Revised: 03/18/2017] [Accepted: 03/31/2017] [Indexed: 12/18/2022]
|
23
|
Zhang S, Ji Z, Sun Z, Li M, Sheng C, Yue M, Yu Y, Chen G, You J. Stable isotope labeling assisted liquid chromatography–tandem mass spectrometry for the analysis of perfluorinated carboxylic acids in serum samples. Talanta 2017; 166:255-261. [DOI: 10.1016/j.talanta.2017.01.069] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2016] [Revised: 01/17/2017] [Accepted: 01/25/2017] [Indexed: 12/24/2022]
|
24
|
A rapid, accurate and sensitive method with the new stable isotopic tags based on microwave-assisted dispersive liquid-liquid microextraction and its application to the determination of hydroxyl UV filters in environmental water samples. Talanta 2017; 167:242-252. [DOI: 10.1016/j.talanta.2017.02.028] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2016] [Revised: 02/06/2017] [Accepted: 02/10/2017] [Indexed: 12/17/2022]
|
25
|
Sensitive determination of thiols in wine samples by a stable isotope-coded derivatization reagent d 0 / d 4 -acridone-10-ethyl-N-maleimide coupled with high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry analysis. J Chromatogr A 2017; 1491:98-107. [DOI: 10.1016/j.chroma.2017.02.042] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Revised: 01/24/2017] [Accepted: 02/19/2017] [Indexed: 12/17/2022]
|
26
|
Determination of parabens in domestic sewage by isotope-coded derivatization coupled with high performance liquid chromatography-tandem mass spectrometry. Microchem J 2017. [DOI: 10.1016/j.microc.2016.10.026] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
27
|
Zhang S, Yu Q, Sheng C, You J. Gas Purge Microextraction Coupled with Stable Isotope Labeling-Liquid Chromatography/Mass Spectrometry for the Analysis of Bromophenols in Aquatic Products. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2016; 64:9452-9458. [PMID: 27960284 DOI: 10.1021/acs.jafc.6b04104] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A green, sensitive, and accurate method was developed for the extraction and determination of bromophenols (BPs) from aquatic products by using organic solvent-free gas purge microsyringe extraction (GP-MSE) technique in combination with stable isotope labeling (SIL) strategy. BPs were extracted by NaHCO3 buffer solution, with recoveries varying from 92.0% to 98.5%. The extracted solution was analyzed by SIL strategy, during which analytes and standards were labeled by 10-methyl-acridone-2-sulfonyl chloride (d0-MASC) and its deuterated counterpart d3-MASC, respectively. The labeling reaction was finished within 10 min with good stability. The liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) sensitivity of BPs was greatly enhanced due to the mass-enhancing property of MASC, while the matrix effect was effectively minimized by the SIL strategy. The limits of detection (LODs) were in the range of 0.10-0.30 μg/kg, while the limits of quantitations (LOQs) were in the range of 0.32-1.0 μg/kg. The proposed method also showed great potential in the qualitative analysis of other bromophenols in the absence of standard.
Collapse
Affiliation(s)
- Shijuan Zhang
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University , West Jingxuan Road no. 57, Qufu 273165, PR China
- Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, Qufu Normal University , Qufu 273165, PR China
| | - Qiuhui Yu
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University , West Jingxuan Road no. 57, Qufu 273165, PR China
- Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, Qufu Normal University , Qufu 273165, PR China
| | - Cuncun Sheng
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University , West Jingxuan Road no. 57, Qufu 273165, PR China
- Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, Qufu Normal University , Qufu 273165, PR China
| | - Jinmao You
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University , West Jingxuan Road no. 57, Qufu 273165, PR China
- Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, Qufu Normal University , Qufu 273165, PR China
- Key Laboratory of Tibetan Medicine Research, Northwest Institute of Plateau Biology, Chinese Academy of Science , Xining 810008, PR China
| |
Collapse
|
28
|
Zhao S, Luo X, Li L. Chemical Isotope Labeling LC-MS for High Coverage and Quantitative Profiling of the Hydroxyl Submetabolome in Metabolomics. Anal Chem 2016; 88:10617-10623. [DOI: 10.1021/acs.analchem.6b02967] [Citation(s) in RCA: 65] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Affiliation(s)
- Shuang Zhao
- Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2, Canada
| | - Xian Luo
- Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2, Canada
| | - Liang Li
- Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2, Canada
| |
Collapse
|
29
|
Isotope-coded ESI-enhancing derivatization reagents for differential analysis, quantification and profiling of metabolites in biological samples by LC/MS: A review. J Pharm Biomed Anal 2016; 130:181-193. [DOI: 10.1016/j.jpba.2016.04.033] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2016] [Revised: 04/20/2016] [Accepted: 04/20/2016] [Indexed: 12/15/2022]
|
30
|
Wang J, Chen Z, Li Z, Yang Y. Magnetic nanoparticles based dispersive micro-solid-phase extraction as a novel technique for the determination of estrogens in pork samples. Food Chem 2016; 204:135-140. [DOI: 10.1016/j.foodchem.2016.02.016] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2015] [Revised: 09/14/2015] [Accepted: 02/01/2016] [Indexed: 11/26/2022]
|
31
|
Multiresidue analysis of endocrine-disrupting compounds and perfluorinated sulfates and carboxylic acids in sediments by ultra-high-performance liquid chromatography–tandem mass spectrometry. J Chromatogr A 2016; 1438:133-42. [DOI: 10.1016/j.chroma.2016.02.022] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2015] [Revised: 02/02/2016] [Accepted: 02/05/2016] [Indexed: 01/15/2023]
|
32
|
Stable isotope labeling assisted liquid chromatography–electrospray tandem mass spectrometry for quantitative analysis of endogenous gibberellins. Talanta 2015; 144:341-8. [DOI: 10.1016/j.talanta.2015.06.056] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2015] [Revised: 06/17/2015] [Accepted: 06/20/2015] [Indexed: 11/20/2022]
|
33
|
Wang F, Zhang S, Sheng C, Zhao X, You J. Sensitive Determination of Amantadine in Microdialysis Samples from Rat Plasma by HPLC with Fluorescence Detection. J LIQ CHROMATOGR R T 2015. [DOI: 10.1080/10826076.2015.1087026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Fangfang Wang
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, Shandong, P. R. China
| | - Shijuan Zhang
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, Shandong, P. R. China
| | - Cuncun Sheng
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, Shandong, P. R. China
| | - Xian’en Zhao
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, Shandong, P. R. China
| | - Jinmao You
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, Shandong, P. R. China
- Key Laboratory of Tibetan Medicine Research, Northwest Institute of Plateau Biology, Chinese Academy of Science, Xining, Qinghai, P. R. China
| |
Collapse
|
34
|
Huan T, Wu Y, Tang C, Lin G, Li L. DnsID in MyCompoundID for rapid identification of dansylated amine- and phenol-containing metabolites in LC-MS-based metabolomics. Anal Chem 2015; 87:9838-45. [PMID: 26327437 DOI: 10.1021/acs.analchem.5b02282] [Citation(s) in RCA: 93] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
High-performance chemical isotope labeling (CIL) liquid chromatography-mass spectrometry (LC-MS) is an enabling technology based on rational design of labeling reagents to target a class of metabolites sharing the same functional group (e.g., all the amine-containing metabolites or the amine submetabolome) to provide concomitant improvements in metabolite separation, detection, and quantification. However, identification of labeled metabolites remains to be an analytical challenge. In this work, we describe a library of labeled standards and a search method for metabolite identification in CIL LC-MS. The current library consists of 273 unique metabolites, mainly amines and phenols that are individually labeled by dansylation (Dns). Some of them produced more than one Dns-derivative (isomers or multiple labeled products), resulting in a total of 315 dansyl compounds in the library. These metabolites cover 42 metabolic pathways, allowing the possibility of probing their changes in metabolomics studies. Each labeled metabolite contains three searchable parameters: molecular ion mass, MS/MS spectrum, and retention time (RT). To overcome RT variations caused by experimental conditions used, we have developed a calibration method to normalize RTs of labeled metabolites using a mixture of RT calibrants. A search program, DnsID, has been developed in www.MyCompoundID.org for automated identification of dansyl labeled metabolites in a sample based on matching one or more of the three parameters with those of the library standards. Using human urine as an example, we illustrate the workflow and analytical performance of this method for metabolite identification. This freely accessible resource is expandable by adding more amine and phenol standards in the future. In addition, the same strategy should be applicable for developing other labeled standards libraries to cover different classes of metabolites for comprehensive metabolomics using CIL LC-MS.
Collapse
Affiliation(s)
- Tao Huan
- Departments of Chemistry and ‡Computing Science, University of Alberta , Edmonton, Alberta T6G2G2, Canada
| | - Yiman Wu
- Departments of Chemistry and ‡Computing Science, University of Alberta , Edmonton, Alberta T6G2G2, Canada
| | - Chenqu Tang
- Departments of Chemistry and ‡Computing Science, University of Alberta , Edmonton, Alberta T6G2G2, Canada
| | - Guohui Lin
- Departments of Chemistry and ‡Computing Science, University of Alberta , Edmonton, Alberta T6G2G2, Canada
| | - Liang Li
- Departments of Chemistry and ‡Computing Science, University of Alberta , Edmonton, Alberta T6G2G2, Canada
| |
Collapse
|
35
|
Huan T, Li L. Quantitative Metabolome Analysis Based on Chromatographic Peak Reconstruction in Chemical Isotope Labeling Liquid Chromatography Mass Spectrometry. Anal Chem 2015; 87:7011-6. [DOI: 10.1021/acs.analchem.5b01434] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Tao Huan
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada
| | - Liang Li
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
36
|
Cai Y, Sun Z, Chen G, Liu X, You J, Zhang C. Rapid analysis of biogenic amines from rice wine with isotope-coded derivatization followed by high performance liquid chromatography-tandem mass spectrometry. Food Chem 2015; 192:388-94. [PMID: 26304364 DOI: 10.1016/j.foodchem.2015.07.024] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2014] [Revised: 04/04/2015] [Accepted: 07/07/2015] [Indexed: 11/24/2022]
Abstract
A pair of isotope-coded derivatization reagents, d0-10-methyl-acridone-2-sulfonyl chloride (d0-MASC, light form) and d3-10-methyl-acridone-2-sulfonyl chloride (d3-MASC, heavy form), were used for labeling biogenic amines (BAs). On basis of the isotope-coded derivatization, a global isotope internal standard quantitative method for determining seven BAs by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. The d0-MASC and d3-MASC can easily label BAs under mild conditions within 15 min at 50 °C. The obtained light and heavy labeled BAs were monitored by the transitions of [M+H](+) → 208 and [M+H](+) → 211, respectively. Relative quantification of BAs was achieved by calculation of the peak area ratios of d0-MASC/d3-MASC labeled derivatives. Excellent linear responses for relative quantification were observed in the range of 1/10-10/1. The developed method has been successfully applied to the quantification of BAs in Chinese rice wine with recoveries ranging from 94.9% to 104.5%.
Collapse
Affiliation(s)
- Yiping Cai
- Key Laboratory of Life-Organic Analysis of Shandong Province, Qufu Normal University, Qufu, PR China
| | - Zhiwei Sun
- Key Laboratory of Life-Organic Analysis of Shandong Province, Qufu Normal University, Qufu, PR China.
| | - Guang Chen
- Key Laboratory of Pharmaceutical Intermediates and Natural Products, Qufu, PR China
| | - Xiaomei Liu
- Key Laboratory of Pharmaceutical Intermediates and Natural Products, Qufu, PR China
| | - Jinmao You
- Key Laboratory of Pharmaceutical Intermediates and Natural Products, Qufu, PR China; Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Xining, PR China.
| | - Caiqing Zhang
- Qianfoshan Hospital, Shandong University, Jinan, PR China
| |
Collapse
|
37
|
Keski-Rahkonen P, Desai R, Jimenez M, Harwood DT, Handelsman DJ. Measurement of Estradiol in Human Serum by LC-MS/MS Using a Novel Estrogen-Specific Derivatization Reagent. Anal Chem 2015; 87:7180-6. [PMID: 26090565 DOI: 10.1021/acs.analchem.5b01042] [Citation(s) in RCA: 80] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is described that employs a novel derivatization reagent for the measurement of serum estradiol (E2), with simultaneous analysis of underivatized testosterone (T) and dihydrotestosterone (DHT). The main advantage of the new derivatization reagent 1,2-dimethylimidazole-5-sulfonyl chloride is its analyte-specific fragmentation that enables monitoring of confirmatory mass transitions with high sensitivity. The reaction mixture can be analyzed without additional purification steps using a 9.5 min gradient run, and sensitive detection is achieved with a triple quadrupole mass spectrometer using atmospheric pressure photoionization. Method validation was performed with human serum samples, including a comparison with a standard LC-MS/MS method using 120 samples from a clinical study, and analysis of certified E2 serum reference materials BCR-576, BCR-577, and BCR-578. The lower limits of quantification for E2, T, and DHT were 0.5 pg/mL, 25 pg/mL, and 0.10 ng/mL, respectively, from a 200-μL sample. Validation results indicated good accuracy and agreement with established, conventional LC-MS/MS assays, demonstrating suitability for analysis of samples containing E2 in the low pg/mL range, such as serum from men, children, and postmenopausal women.
Collapse
Affiliation(s)
- Pekka Keski-Rahkonen
- †ANZAC Research Institute, University of Sydney and Andrology Department, Concord Hospital, NSW Health, Sydney, NSW 2139, Australia
| | - Reena Desai
- †ANZAC Research Institute, University of Sydney and Andrology Department, Concord Hospital, NSW Health, Sydney, NSW 2139, Australia
| | - Mark Jimenez
- †ANZAC Research Institute, University of Sydney and Andrology Department, Concord Hospital, NSW Health, Sydney, NSW 2139, Australia
| | - D Tim Harwood
- †ANZAC Research Institute, University of Sydney and Andrology Department, Concord Hospital, NSW Health, Sydney, NSW 2139, Australia
| | - David J Handelsman
- †ANZAC Research Institute, University of Sydney and Andrology Department, Concord Hospital, NSW Health, Sydney, NSW 2139, Australia
| |
Collapse
|
38
|
Zhou R, Huan T, Li L. Development of versatile isotopic labeling reagents for profiling the amine submetabolome by liquid chromatography–mass spectrometry. Anal Chim Acta 2015; 881:107-16. [DOI: 10.1016/j.aca.2015.04.021] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Revised: 04/06/2015] [Accepted: 04/11/2015] [Indexed: 01/09/2023]
|
39
|
Song C, Zhang S, Ji Z, Li Y, You J. Accurate Determination of Amino Acids in Serum Samples by Liquid Chromatography-Tandem Mass Spectrometry Using a Stable Isotope Labeling Strategy. J Chromatogr Sci 2015; 53:1536-41. [PMID: 25940231 DOI: 10.1093/chromsci/bmv049] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2014] [Indexed: 11/14/2022]
Abstract
An accurate and sensitive liquid chromatography-tandem mass spectrometry method was developed for the analysis of amino acids (isoleucine, leucine, valine, tyrosine, phenylalanine and tryptophan) in serum samples using a stable isotope labeling strategy. Amino acid samples and standards were, respectively, derivatized by 10-methyl-acridone-2-sulfonyl chloride (d0-MASC) and its deuterated counterpart d3-MASC to form isotopic pairs which co-eluted and were detected by an MS detector at the same time. Accurate internal standard-based quantification was thereby achieved without the use of any internal standard analogy. The labeling reaction of MASC with amino acids is fast, simple and robust. Besides, derivatization increased the molecular weight of amino acids, and therefore they were shifted out of the background noise which was often observed in low mass region. The instrument LODs were in the range of 1.0-2.5 nmol/L. Linearities calculated by comparing theoretical peak area ratios of d0-/d3-MASC derivatives with the experimental peak area ratios were excellent with correlation coefficients of >0.995. The proposed method was successfully applied to the analysis of amino acids in serum samples with high sensitivity and accuracy.
Collapse
Affiliation(s)
- Cuihua Song
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu 273165, PR China
| | - Shijuan Zhang
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu 273165, PR China
| | - Zhongyin Ji
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu 273165, PR China Key Laboratory of Tibetan Medicine Research, Northwest Institute of Plateau Biology, Chinese Academy of Science, Xining, PR China
| | - Yipeng Li
- Qufu People's Hospital, Qufu, PR China
| | - Jinmao You
- Shandong Province Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu 273165, PR China Key Laboratory of Tibetan Medicine Research, Northwest Institute of Plateau Biology, Chinese Academy of Science, Xining, PR China
| |
Collapse
|
40
|
Kim J, Abdulwahab S, Choi K, Lafrenière NM, Mudrik JM, Gomaa H, Ahmado H, Behan LA, Casper RF, Wheeler AR. A Microfluidic Technique for Quantification of Steroids in Core Needle Biopsies. Anal Chem 2015; 87:4688-95. [DOI: 10.1021/ac5043297] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Jihye Kim
- Department
of Chemistry, University of Toronto, 80 Saint George Street, Toronto, Ontario M5S 3H6, Canada
| | - Sara Abdulwahab
- Department
of Chemistry, University of Toronto, 80 Saint George Street, Toronto, Ontario M5S 3H6, Canada
| | - Kihwan Choi
- Department
of Chemistry, University of Toronto, 80 Saint George Street, Toronto, Ontario M5S 3H6, Canada
- Donnelly Centre
for Cellular and Biomolecular Research, University of Toronto, 160 College
Street, Toronto, Ontario M5S 3E1, Canada
| | - Nelson M. Lafrenière
- Department
of Chemistry, University of Toronto, 80 Saint George Street, Toronto, Ontario M5S 3H6, Canada
| | - Jared M. Mudrik
- Department
of Chemistry, University of Toronto, 80 Saint George Street, Toronto, Ontario M5S 3H6, Canada
| | - Hala Gomaa
- Samuel Lunenfeld
Research Institute, Mount Sinai Hospital, 25 Orde Street, Toronto, Ontario M5T 3H7, Canada
| | - Hend Ahmado
- Samuel Lunenfeld
Research Institute, Mount Sinai Hospital, 25 Orde Street, Toronto, Ontario M5T 3H7, Canada
| | - Lucy-Ann Behan
- Samuel Lunenfeld
Research Institute, Mount Sinai Hospital, 25 Orde Street, Toronto, Ontario M5T 3H7, Canada
| | - Robert F. Casper
- Samuel Lunenfeld
Research Institute, Mount Sinai Hospital, 25 Orde Street, Toronto, Ontario M5T 3H7, Canada
| | - Aaron R. Wheeler
- Department
of Chemistry, University of Toronto, 80 Saint George Street, Toronto, Ontario M5S 3H6, Canada
- Institute of Biomaterials
and Biomedical Engineering, University of Toronto, 164 College Street, Toronto, Ontario M5S 3G9, Canada
- Donnelly Centre
for Cellular and Biomolecular Research, University of Toronto, 160 College
Street, Toronto, Ontario M5S 3E1, Canada
| |
Collapse
|
41
|
Pan X, Dong F, Xu J, Liu X, Chen Z, Liu N, Chen X, Tao Y, Zhang H, Zheng Y. Simultaneous determination of chlorantraniliprole and cyantraniliprole in fruits, vegetables and cereals using ultra-high-performance liquid chromatography–tandem mass spectrometry with the isotope-labelled internal standard method. Anal Bioanal Chem 2015; 407:4111-20. [DOI: 10.1007/s00216-015-8603-8] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Revised: 02/11/2015] [Accepted: 02/26/2015] [Indexed: 11/25/2022]
|
42
|
CAI YP, SUN ZW, WANG XY, SUO YR, YOU JM. Determination of Plant Growth Regulators in Vegetable by High Performance Liquid Chromatography-Tandem Mass Spectrometry Coupled with Isotop-coded Derivatization. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2015. [DOI: 10.1016/s1872-2040(15)60814-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
43
|
Huan T, Li L. Counting Missing Values in a Metabolite-Intensity Data Set for Measuring the Analytical Performance of a Metabolomics Platform. Anal Chem 2014; 87:1306-13. [DOI: 10.1021/ac5039994] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Affiliation(s)
- Tao Huan
- Department of Chemistry, University of Alberta, Edmonton, Alberta T6G2G2, Canada
| | - Liang Li
- Department of Chemistry, University of Alberta, Edmonton, Alberta T6G2G2, Canada
| |
Collapse
|
44
|
Zhou R, Li L. Effects of sample injection amount and time-of-flight mass spectrometric detection dynamic range on metabolome analysis by high-performance chemical isotope labeling LC-MS. J Proteomics 2014; 118:130-9. [PMID: 25134441 DOI: 10.1016/j.jprot.2014.08.004] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2014] [Revised: 07/26/2014] [Accepted: 08/04/2014] [Indexed: 12/24/2022]
Abstract
UNLABELLED The effect of sample injection amount on metabolome analysis in a chemical isotope labeling (CIL) liquid chromatography-mass spectrometry (LC-MS) platform was investigated. The performance of time-of-flight (TOF) mass spectrometers with and without a high-dynamic-range (HD) detection system was compared in the analysis of (12)C2/(13)C2-dansyl labeled human urine samples. An average of 1635 ± 21 (n = 3) peak pairs or putative metabolites was detected using the HD-TOF-MS, compared to 1429 ± 37 peak pairs from a conventional or non-HD TOF-MS. In both instruments, signal saturation was observed. However, in the HD-TOF-MS, signal saturation was mainly caused by the ionization process, while in the non-HD TOF-MS, it was caused by the detection process. To extend the MS detection range in the non-HD TOF-MS, an automated switching from using (12)C to (13)C-natural abundance peaks for peak ratio calculation when the (12)C peaks are saturated has been implemented in IsoMS, a software tool for processing CIL LC-MS data. This work illustrates that injecting an optimal sample amount is important to maximize the metabolome coverage while avoiding the sample carryover problem often associated with over-injection. A TOF mass spectrometer with an enhanced detection dynamic range can also significantly increase the number of peak pairs detected. BIOLOGICAL SIGNIFICANCE In chemical isotope labeling (CIL) LC-MS, relative metabolite quantification is done by measuring the peak ratio of a (13)C2-/(12)C2-labeled peak pair for a given metabolite present in two comparative samples. The dynamic range of peak ratio measurement does not need to be very large, as only subtle changes of metabolite concentrations are encountered in most metabolomic studies where relative metabolome quantification of different groups of samples is performed. However, the absolute concentrations of different metabolites can be very different, requiring a technique to provide a wide detection dynamic range to allow the detection of as many peak pairs as possible. In this work, we demonstrated that controlling the sample injection amount into LC-MS was critical to achieve the optimal detectability while avoiding sample carry-over problem. In addition, the use of a high-dynamic-range TOF system increased the number of peak pairs detected, compared to a conventional TOF system. We also investigated the ionization and detection saturation factors limiting the dynamic range of detection. This article is part of a Special Issue entitled: Protein dynamics in health and disease. Guest Editors: Pierre Thibault and Anne-Claude Gingras.
Collapse
Affiliation(s)
- Ruokun Zhou
- Departments of Chemistry, University of Alberta, Edmonton, Alberta, Canada
| | - Liang Li
- Departments of Chemistry, University of Alberta, Edmonton, Alberta, Canada.
| |
Collapse
|
45
|
DPV and SWV Determination of Estrone Using a Cathodically Pretreated Boron-Doped Diamond Electrode. ELECTROANAL 2014. [DOI: 10.1002/elan.201400118] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
46
|
Zhou R, Tseng CL, Huan T, Li L. IsoMS: Automated Processing of LC-MS Data Generated by a Chemical Isotope Labeling Metabolomics Platform. Anal Chem 2014; 86:4675-9. [DOI: 10.1021/ac5009089] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Ruokun Zhou
- Department of Chemistry, University of Alberta, Edmonton, Alberta T6G2G2, Canada
| | - Chiao-Li Tseng
- Department of Chemistry, University of Alberta, Edmonton, Alberta T6G2G2, Canada
| | - Tao Huan
- Department of Chemistry, University of Alberta, Edmonton, Alberta T6G2G2, Canada
| | - Liang Li
- Department of Chemistry, University of Alberta, Edmonton, Alberta T6G2G2, Canada
| |
Collapse
|
47
|
Sun X, Ouyang Y, Chu J, Yan J, Yu Y, Li X, Yang J, Yan C. An in-advance stable isotope labeling strategy for relative analysis of multiple acidic plant hormones in sub-milligram Arabidopsis thaliana seedling and a single seed. J Chromatogr A 2014; 1338:67-76. [PMID: 24636756 DOI: 10.1016/j.chroma.2014.02.056] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2013] [Revised: 02/03/2014] [Accepted: 02/20/2014] [Indexed: 12/26/2022]
Abstract
A sensitive and reliable in-advance stable isotope labeling strategy was developed for simultaneous relative quantification of 8 acidic plant hormones in sub-milligram amount of plant materials. Bromocholine bromide (BETA) and its deuterated counterpart D9-BETA were used to in-advance derivatize control and sample extracts individually, which were then combined and subjected to solid-phase extraction (SPE) purification followed by UPLC-MS/MS analysis. Relative quantification of target compounds was obtained by calculation of the peak area ratios of BETA/D9-BETA labeled plant hormones. The in-advance stable isotope labeling strategy realized internal standard-based relative quantification of multiple kinds of plant hormones independent of availability of internal standard of every analyte with enhanced sensitivity of 1-3 orders of magnitude. Meanwhile, the in-advance labeling contributes to higher sample throughput and more reliability. The method was successfully applied to determine 8 plant hormones in 0.8mg DW (dry weight) of seedlings and 4 plant hormones from single seed of Arabidopsis thaliana. The results show the potential of the method in relative quantification of multiple plant hormones in tiny plant tissues or organs, which will advance the knowledge of the crosstalk mechanism of plant hormones.
Collapse
Affiliation(s)
- Xiaohong Sun
- National Center for Plant Gene Research (Beijing), Institute of Genetics and Developmental Biology, Chinese Academy of Sciences, 1-2 Beichen West Road, Beijing 100101, China
| | - Yue Ouyang
- National Center for Plant Gene Research (Beijing), Institute of Genetics and Developmental Biology, Chinese Academy of Sciences, 1-2 Beichen West Road, Beijing 100101, China; Department of Pharmaceutical Analysis, Heilongjiang University of Chinese Medicine, Harbin 150040, China
| | - Jinfang Chu
- National Center for Plant Gene Research (Beijing), Institute of Genetics and Developmental Biology, Chinese Academy of Sciences, 1-2 Beichen West Road, Beijing 100101, China
| | - Jing Yan
- Department of Pharmaceutical Analysis, Heilongjiang University of Chinese Medicine, Harbin 150040, China
| | - Yan Yu
- Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
| | - Xiaoqiang Li
- Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
| | - Jun Yang
- Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China.
| | - Cunyu Yan
- National Center for Plant Gene Research (Beijing), Institute of Genetics and Developmental Biology, Chinese Academy of Sciences, 1-2 Beichen West Road, Beijing 100101, China.
| |
Collapse
|
48
|
Zhou R, Guo K, Li L. 5-Diethylamino-naphthalene-1-sulfonyl Chloride (DensCl): A Novel Triplex Isotope Labeling Reagent for Quantitative Metabolome Analysis by Liquid Chromatography Mass Spectrometry. Anal Chem 2013; 85:11532-9. [DOI: 10.1021/ac403000n] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Ruokun Zhou
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada
| | - Kevin Guo
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada
| | - Liang Li
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
49
|
Peng J, Li L. Liquid–liquid extraction combined with differential isotope dimethylaminophenacyl labeling for improved metabolomic profiling of organic acids. Anal Chim Acta 2013; 803:97-105. [DOI: 10.1016/j.aca.2013.07.045] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2013] [Revised: 07/15/2013] [Accepted: 07/18/2013] [Indexed: 12/15/2022]
|
50
|
Simultaneous analysis of eight phenolic environmental estrogens in blood using dispersive micro-solid-phase extraction combined with ultra fast liquid chromatography–tandem mass spectrometry. Talanta 2013; 115:787-97. [DOI: 10.1016/j.talanta.2013.05.053] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Revised: 05/17/2013] [Accepted: 05/21/2013] [Indexed: 11/18/2022]
|