1
|
Jung WY, Kim JW, Kim SR, Park M. Heavy metal deposition and parameter change of soft contact lenses by exposure to particulate matter : Parameter change of SCL due to exposure to PM and heavy metal deposition. BMC Ophthalmol 2023; 23:423. [PMID: 37864135 PMCID: PMC10588221 DOI: 10.1186/s12886-023-03154-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 09/25/2023] [Indexed: 10/22/2023] Open
Abstract
BACKGROUND Particulate matter (PM) is known to contain heavy metals and be harmful to the tissues and organs of the human body including the eyes. As such, in this study, the deposition of heavy metals from PM on soft contact lenses was examined, and changes in the lens parameters were further investigated. METHODS Six types of soft contact lenses were exposed to captured PM10 for eight hours. The central thickness, water content, refractive power, and oxygen transmissibility of each contact lens were measured after analyzing the amounts of six heavy metals adsorbed on the contact lenses. RESULTS Lead, manganese, barium, arsenic, vanadium, and cadmium were detected in the captured PM, and only lead was adsorbed on all soft contact lenses except senofilcon C. The largest deposition was 23.21 ± 0.70 (10- 3)µg/lens of the lead on lotrafilcon B. The oxygen transmissibility of nelfilcon A exhibited statistically significant changes, however, it was within the ISO standard tolerance. Nevertheless, changes in the central thickness, water content, and refractive power of each soft contact lens were not statistically significant. CONCLUSIONS This study revealed that a considerable amount of lead in PM10 was adsorbed on soft contact lenses. Amongst lens parameters, only oxygen transmissibility changed significantly. Thus, wearing soft contact lenses under high PM10 concentration might affect the physiology of the eyes.
Collapse
Affiliation(s)
- Won Young Jung
- Department of Optometry, Seoul National University of Science and Technology, 232, Gongneung-ro, Nowon-gu, Seoul, Republic of Korea
| | | | - So Ra Kim
- Department of Optometry, Seoul National University of Science and Technology, 232, Gongneung-ro, Nowon-gu, Seoul, Republic of Korea
| | - Mijung Park
- Department of Optometry, Seoul National University of Science and Technology, 232, Gongneung-ro, Nowon-gu, Seoul, Republic of Korea.
| |
Collapse
|
2
|
Orive Bañuelos A, Santamaría Carro A, Feijóo Lera R, Sacristán Egüén C, Andollo Victoriano N, Etxebarria Ecenarro J. Candida Colonization on the Surface of Contact Lenses in Long-Term Wearers and Boston Type 1 Keratoprosthesis Patients Presenting as White Mulberry-Shaped Deposits. Eye Contact Lens 2023; 49:188-192. [PMID: 37088944 DOI: 10.1097/icl.0000000000000984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/14/2023] [Indexed: 04/25/2023]
Abstract
PURPOSE To report Candida colonies on the surface of the contact lens in long-term contact lens wearers and patients with Boston type 1 keratoprosthesis (KPro I). METHODS A retrospective study was performed based on analyzing cultures from bandage contact lenses with small whitish mulberry-shaped deposits on their surface. RESULTS Eight samples (from seven patients) were positive for Candida. Seven of the eight were positive for Candida parapsilosis. CONCLUSIONS The whitish deposits on contact lenses are often Candida colonies that colonize the surface but do not cause an active infection in the eye. C. parapsilosis is well-known for colonizing prosthetic devices. We underline the importance of including Candida species in the differential diagnosis of lens deposits, especially in susceptible patients such as keratoprosthesis carriers.
Collapse
Affiliation(s)
- Ana Orive Bañuelos
- Department of Ophthalmology (A.O.B., A.S.C., R.F.L., C.S.E., J.E.E.), BioCruces Bizkaia Health Research Institute, University Hospital of Cruces, Barakaldo, Spain; and Department of Cell Biology and Histology (N.A.V., J.E.E.), School of Medicine and Nursing, University of the Basque Country (UPV/EHU), Leioa, Spain
| | | | | | | | | | | |
Collapse
|
3
|
Contact Lens Wear Induces Alterations of Lactoferrin Functionality in Human Tears. Pharmaceutics 2022; 14:pharmaceutics14102188. [PMID: 36297623 PMCID: PMC9612143 DOI: 10.3390/pharmaceutics14102188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 10/10/2022] [Accepted: 10/12/2022] [Indexed: 11/06/2022] Open
Abstract
The tear film is a complex matrix composed of several molecular classes, from small metal ions to macromolecules. Contact lens (CL) wear can affect the protein homeostasis of the tear film, by accumulating deposits on the CL surface and/or altering their structural and functional properties. This work investigates the effect of CL wear on lactoferrin (Lf), one of the most abundant tear proteins, known as an unspecific biomarker of inflammation. Tears from eight volunteers were collected and analyzed after alternated periods of CL wear and without CL. The experimental approach is to probe Lf into unprocessed human tears by the peculiar fluorescence emission originating from complex formation of Lf with terbium (Tb3+) at the iron-binding sites. The experimental data indicate that CL wear does not significantly affect the total amount of Lf. On the other hand, Lf affinity for Tb3+ is reduced upon CL wear, suggesting relevant changes in Lf structure and possible alterations of protein functionality. Future studies based on this approach will help define CL features (material, lens-care solution, wearing time, etc.) with minimal effects on tear protein activity, in order to obtain more biocompatible and comfortable devices.
Collapse
|
4
|
Masoudi S, Willcox M. Development of an enzymatic method for the evaluation of protein deposition on contact lenses. BIOFOULING 2022; 38:84-99. [PMID: 35016572 DOI: 10.1080/08927014.2021.2019225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 12/09/2021] [Accepted: 12/10/2021] [Indexed: 06/14/2023]
Abstract
The aim of this study was to evaluate a new digestion method to quantify protein deposition on contact lenses. Four silicone hydrogel and one hydrogel contact lens material were incubated in lactoferrin, lysozyme, immunoglobulin A, and bovine serum albumin solutions at approximate physiological concentrations and temperature. Immobilized trypsin was used to digest the protein deposits from the contact lens surfaces. The total protein absorbed to lenses was extracted and digested using sequencing grade trypsin. The tryptic peptides were quantified using selected reaction monitoring mass spectrometry. The concentration of surface protein deposits was either lower than or the same as the total protein for all lens types and proteins. Immobilised trypsin can digest protein deposits from the surface of contact lenses. This ability to analyse the amount of protein at a contact lens surface may help in elucidating the effect of surface deposition on clinical outcomes during lens wear.
Collapse
Affiliation(s)
- Simin Masoudi
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
5
|
The Effect of Different Cleaning Methods on Protein Deposition and Optical Characteristics of Orthokeratology Lenses. Polymers (Basel) 2021; 13:polym13244318. [PMID: 34960869 PMCID: PMC8707220 DOI: 10.3390/polym13244318] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/06/2021] [Accepted: 12/07/2021] [Indexed: 11/29/2022] Open
Abstract
Orthokeratology lenses are commonly used for myopia control, especially in children. Tear lipids and proteins are immediately adsorbed when the lens is put on the cornea, and protein deposition may cause discomfort or infection. Therefore, we established an in vitro protein deposition analysis by mimicking the current cleaning methods for orthokeratology lens wearers for both short-term and long-term period. The results showed that the amounts of tear proteins accumulated daily and achieved a balance after 14 days when the lens was rubbed to clean or not. Protein deposition also affected the optical characteristics of the lens regardless of cleaning methods. Our results provided an in vitro analysis for protein deposition on the lens, and they may provide a potential effective method for developing care solutions or methods that can more effectively remove tear components from orthokeratology lenses.
Collapse
|
6
|
Walsh K, Jones L, Moody K. Addressing common myths and misconceptions in soft contact lens practice. Clin Exp Optom 2021; 105:459-473. [PMID: 34886744 DOI: 10.1080/08164622.2021.2003693] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Advances in contact lens technology over the past 50 years since the commercialisation of the first soft lenses in 1971 have been incredible, with significant changes in contact lens materials, frequency of replacement, care systems and lens designs occurring. However, despite the widespread availability of contact lenses, penetration rates for those who need vision correction remain in the low single digits and many practitioners seem to hold on to concepts around the potential value of contact lenses that appear based in the dim and distant past and are certainly no longer valid today. This review addresses 10 common 'myths and misconceptions' around soft contact lenses using an evidence-based approach that can hopefully dispel some of these incorrect assumptions.
Collapse
Affiliation(s)
- Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.,Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Shatin, Hong Kong
| | - Kurt Moody
- Johnson & Johnson Vision, Jacksonville, Florida, USA
| |
Collapse
|
7
|
Chan VWY, Phan CM, Ngo W, Jones L. Lysozyme Deposition on Contact Lenses in an In Vitro Blink-Simulation Eye Model Versus a Static Vial Deposition Model. Eye Contact Lens 2021; 47:388-393. [PMID: 33840748 DOI: 10.1097/icl.0000000000000784] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/07/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate active lysozyme deposition on daily disposable (DD) contact lenses (CL) using a novel in vitro blink model. METHODS Three conventional hydrogel DD CL materials (etafilcon A, omafilcon A, nelfilcon A) and three silicone hydrogel DD CL materials (delefilcon A, senofilcon A, somofilcon A) were tested. The device blink rate was set to 6 blinks/min with a tear flow rate of 1 μL/min using an artificial tear solution (ATS) containing lysozyme and other typical tear film components. After incubation at 2, 4, or 8 hr, lenses were removed, and lysozyme activity was measured. A separate experiment was conducted with lenses incubated in a static vial containing 480 μL of ATS. RESULTS Etafilcon A deposited significantly higher amounts of active lysozyme (402±102 μg/lens) than other lens materials after 8 hr (P<0.0001). Etafilcon A had a higher amount of active lysozyme using the blink model compared with the static vial (P=0.0435), whereas somofilcon A (P=0.0076) and senofilcon A (P=0.0019) had a higher amount of lysozyme activity in the vial compared with the blink model. CONCLUSION The blink model can be tuned to provide quantitative data that closely mimics ex vivo studies and can be used to model deposition of lysozyme on CL materials.
Collapse
Affiliation(s)
- Vivian W Y Chan
- Centre for Ocular Research and Education (CORE) (V.W.Y.C., C.-M.P., W.N., L.J.), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada ; and Centre for Eye and Vision Research (CEVR) (C.-M.P., W.N., L.J.), Hong Kong, China
| | | | | | | |
Collapse
|
8
|
Efron N, Brennan NA, Chalmers RL, Jones L, Lau C, Morgan PB, Nichols JJ, Szczotka-Flynn LB, Willcox MD. Thirty years of 'quiet eye' with etafilcon A contact lenses. Cont Lens Anterior Eye 2020; 43:285-297. [PMID: 32278644 DOI: 10.1016/j.clae.2020.03.015] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 03/27/2020] [Accepted: 03/28/2020] [Indexed: 11/17/2022]
Abstract
Frequent replacement contact lenses made from the etafilcon A hydrogel lens material were introduced onto the market over 30 years ago, and etafilcon A remains the most widely used hydrogel lens material today. Although the prescribing of silicone hydrogel lenses is increasing, millions of lens wearers globally have been wearing hydrogel lenses for many years and exhibit a physiologically-stable 'quiet eye', with a low profile of adverse events. Hydrogel lenses are demonstrated to maintain a low inflammatory response and infection risk profile during daily wear, which in the case of etafilcon A, may be related to its low modulus, and the naturally-protective, anti-microbial, non-denatured lysozyme absorbed into the lens from the tear fluid. Although improved corneal physiology from decreased hypoxia with silicone hydrogel lenses is well accepted, equivalent levels of corneal oxygenation are maintained during daily wear of low to medium powered hydrogel lenses, which do not impede the daily corneal de-swelling process, and do not induce clinically significant changes in ocular health. Therefore, hydrogel lenses remain an important alternative for daily wear in modern contact lens practice.
Collapse
Affiliation(s)
- Nathan Efron
- Institute of Health and Biomedical Innovation, School of Optometry and Vision Science, Queensland University of Technology, Australia.
| | | | | | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada
| | - Charis Lau
- Johnson & Johnson Vision, Inc, Jacksonville, FL, USA
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, UK
| | - Jason J Nichols
- The University of Alabama at Birmingham, School of Optometry, Birmingham, AL, USA
| | - Loretta B Szczotka-Flynn
- University Hospitals Eye Institute, University Hospitals Cleveland Medical Center, Department of Ophthalmology & Visual Sciences, Case Western Reserve University, Cleveland, OH, USA
| | - Mark D Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
9
|
Dantam J, Subbaraman LN, Jones L. Adhesion of Pseudomonas aeruginosa, Achromobacter xylosoxidans, Delftia acidovorans, Stenotrophomonas maltophilia to contact lenses under the influence of an artificial tear solution. BIOFOULING 2020; 36:32-43. [PMID: 31973583 DOI: 10.1080/08927014.2019.1710832] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Revised: 12/25/2019] [Accepted: 12/27/2019] [Indexed: 06/10/2023]
Abstract
Corneal infection is a devastating sight-threatening complication that is associated with contact lens (CL) wear, commonly caused by Pseudomonas aeruginosa. Lately, Achromobacter xylosoxidans, Delftia acidovorans, and Stenotrophomonas maltophilia have been associated with corneal infection. This study investigated the adhesion of these emerging pathogens to CLs, under the influence of an artificial tear solution (ATS) containing a variety of components commonly found in human tears. Two different CL materials, etafilcon A and senofilcon A, either soaked in an ATS or phosphate buffered saline, were exposed to the bacteria. Bacterial adhesion was investigated using a radio-labeling technique (total counts) and plate count method (viable counts). The findings from this study revealed that in addition to P. aeruginosa, among the emerging pathogens evaluated, A. xylosoxidans showed an increased propensity for adherence to both CL materials and S. maltophilia showed lower viability. ATS influenced the viable counts more than the total counts on CLs.
Collapse
Affiliation(s)
- Jaya Dantam
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| |
Collapse
|
10
|
Montaser A, Rehan M, El-Naggar ME. pH-Thermosensitive hydrogel based on polyvinyl alcohol/sodium alginate/N-isopropyl acrylamide composite for treating re-infected wounds. Int J Biol Macromol 2019; 124:1016-1024. [DOI: 10.1016/j.ijbiomac.2018.11.252] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2018] [Revised: 11/15/2018] [Accepted: 11/26/2018] [Indexed: 10/27/2022]
|