1
|
Zhang T, Huang C, Jiao Y, Shao L, Jiang D, Li F, Li W, Gao X. ICP-MS and fluorescence dual-mode detection of ZIKV-RNA based on quantum dot labeling with hybridization chain reaction. Talanta 2024; 269:125463. [PMID: 38016323 DOI: 10.1016/j.talanta.2023.125463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 10/04/2023] [Accepted: 11/21/2023] [Indexed: 11/30/2023]
Abstract
The detection of Zika virus (ZIKV) is of great significance to human life and health. Herein, we presented an ICP-MS and fluorescent dual-mode sensor for quantitative analysis of Zika virus RNA fragments (ZIKV-RNA), which employed quantum dots (QDs) as signal tags and combined with hybridization chain reaction (HCR). The dual-mode sensor realized cross-checking of the analysis results and improved the assay accuracy. Firstly, the single-stranded DNA (ssDNA) was anchored on the surface of magnetic beads (MBs). Afterward, HCR was conducted with probe DNA-CdSe quantum dots conjugates (pDNA-QDs) and link DNA (lDNA), producing the MBs-ssDNA-[pDNA-QDs-lDNA]n conjugates. In the presence of target ZIKV-RNA, a strand displacement reaction occurred, leading to the dissociation of the [pDNA-QDs-lDNA]n labels from the conjugates into the solution. Finally, the signal intensity was detected using ICP-MS and fluorescence analysis, with achieved limits of detection of 131 pM and 152 pM, respectively. The inter-assay RSD values of fluorescence and ICP-MS were 3.94 % and 4.26 % at 10 nM level, respectively, showing that the method had good precision. This method showed high selectivity and was applied to the analysis of biological fluids. There was no significant difference between the results of ICP-MS modes and fluorescence mode. This method offers a new strategy for sensitivity analysis of ZIKV-RNA and exhibits promise in clinical applications for diagnosis.
Collapse
Affiliation(s)
- Tianran Zhang
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan, 250000, People's Republic of China; Department of Physical and Chemical Inspection, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, 250000, People's Republic of China; Yantai Center for Disease Control and Prevention, Yantai, 264000, People's Republic of China
| | - Chao Huang
- Department of Pharmacy, Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan, 250014, People's Republic of China
| | - Yanni Jiao
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan, 250000, People's Republic of China; Department of Physical and Chemical Inspection, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, 250000, People's Republic of China
| | - Lijun Shao
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan, 250000, People's Republic of China
| | - Dafeng Jiang
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan, 250000, People's Republic of China; Department of Physical and Chemical Inspection, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, 250000, People's Republic of China.
| | - Fenghua Li
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan, 250000, People's Republic of China
| | - Wei Li
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan, 250000, People's Republic of China
| | - Xibao Gao
- Department of Physical and Chemical Inspection, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, 250000, People's Republic of China.
| |
Collapse
|
2
|
Fisher R, Lustig Y, Sklan EH, Schwartz E. The Role of NS1 Protein in the Diagnosis of Flavivirus Infections. Viruses 2023; 15:v15020572. [PMID: 36851784 PMCID: PMC9963814 DOI: 10.3390/v15020572] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 02/12/2023] [Accepted: 02/17/2023] [Indexed: 02/22/2023] Open
Abstract
Nonstructural protein 1 (NS1) is a glycoprotein among the flavivirus genus. It is found in both membrane-associated and soluble secreted forms, has an essential role in viral replication, and modulates the host immune response. NS1 is secreted from infected cells within hours after viral infection, and thus immunodetection of NS1 can be used for early serum diagnosis of dengue fever infections instead of real-time (RT)-PCR. This method is fast, simple, and affordable, and its availability could provide an easy point-of-care testing solution for developing countries. Early studies show that detecting NS1 in cerebrospinal fluid (CSF) samples is possible and can improve the surveillance of patients with dengue-associated neurological diseases. NS1 can be detected postmortem in tissue specimens. It can also be identified using noninvasive methods in urine, saliva, and dried blood spots, extending the availability and effective detection period. Recently, an enzyme-linked immunosorbent assay (ELISA) assay for detecting antibodies directed against Zika virus NS1 has been developed and used for diagnosing Zika infection. This NS1-based assay was significantly more specific than envelope protein-based assays, suggesting that similar assays might be more specific for other flaviviruses as well. This review summarizes the knowledge on flaviviruses' NS1's potential role in antigen and antibody diagnosis.
Collapse
Affiliation(s)
- Ron Fisher
- Department of Otolaryngology/Head & Neck Surgery, Hadassah Hebrew; University Medical Center, Jerusalem 91120, Israel
| | - Yaniv Lustig
- Central Virology Laboratory, Ministry of Health, Sheba Medical Center, Ramat-Gan 52621, Israel
- Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv 69978, Israel
| | - Ella H. Sklan
- Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv 69978, Israel
| | - Eli Schwartz
- Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv 69978, Israel
- The Center of Geographic Medicine and Tropical Diseases, Sheba Medical Center, Ramat-Gan 52621, Israel
- Correspondence:
| |
Collapse
|
3
|
Liu W, Long X, Wan K, Yin M, Yin Y, Zhang B, Li L, Song Y. The endogenous factors affecting the detection of serum SARS-CoV-2 IgG/IgM antibodies by ELISA. J Med Virol 2021; 94:1976-1982. [PMID: 34967441 PMCID: PMC9015225 DOI: 10.1002/jmv.27557] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 12/16/2021] [Accepted: 12/27/2021] [Indexed: 11/12/2022]
Abstract
To investigate endogenous interference factors of the detection results of novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgM/IgG. Enzyme-linked immunosorbent assay (ELISA) was used to detect SARS-CoV-2 IgM/IgG in sera of 200 patients without COVID-19 infection, including rheumatoid factor (RF) positive group, antinuclear antibody (ANA) positive group, pregnant women group and normal senior group, with 50 in each group and 100 normal controls. The level of SARS-CoV-2 IgG in pregnant women was significantly higher than that in normal control group (P = 0.000), but there was no significant difference between other groups. The levels of SARS-CoV-2 IgM in pregnant women group, normal senior group, ANA positive group and RF positive group were significantly higher than that in normal control group (P<0.05), with significant higher false positive rates in these groups (P = 0.036, P = 0.004, P = 0.000, vs normal control group). Serum RF caused SARS-CoV-2 IgM false-positive in concentration dependent manner, especially when its concentration was higher than 110.25 IU/L, and urea dissociation test can turn the false positive to negative. ANA, normal seniors, pregnant women and RF can lead to false-positive reactivity of SARS-CoV-2 IgM and/or IgG detected using ELISA. These factors should be considered when SARS-CoV-2 IgM or IgG detection is positive, false positive samples caused by RF positive can be used for urea dissociation test. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Weiping Liu
- Department of Clinical Laboratory, Zigong First People's Hospital, Zigong, Sichuan, China
| | - Xia Long
- Department of Clinical Laboratory, Zigong First People's Hospital, Zigong, Sichuan, China
| | - Kexing Wan
- Department of Clinical Laboratory, Zigong First People's Hospital, Zigong, Sichuan, China
| | - Minggang Yin
- Department of Clinical Laboratory, Zigong First People's Hospital, Zigong, Sichuan, China
| | - Yi Yin
- Department of Clinical Laboratory, Zigong First People's Hospital, Zigong, Sichuan, China
| | - Bo Zhang
- Department of Clinical Laboratory, Zigong First People's Hospital, Zigong, Sichuan, China
| | - Lin Li
- Department of Laboratory Medicine, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Chengdu, Sichuan, China
| | - Yaohui Song
- Department of Clinical Laboratory, Zigong First People's Hospital, Zigong, Sichuan, China
| |
Collapse
|
4
|
Mendonça PD, Santos LKB, Foguel MV, Rodrigues MAB, Cordeiro MT, Gonçalves LM, Marques ETA, Dutra RF. NS1 glycoprotein detection in serum and urine as an electrochemical screening immunosensor for dengue and Zika virus. Anal Bioanal Chem 2021; 413:4873-4885. [PMID: 34152457 DOI: 10.1007/s00216-021-03449-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 05/21/2021] [Accepted: 05/31/2021] [Indexed: 11/28/2022]
Abstract
The incidence of infection by the dengue virus (DENV) has grown dramatically, reaching 128 countries in tropical and subtropical regions worldwide, with a pattern of hyper-endemicity. DENV is a mosquito-borne disease having four serotypes, one or two circulating in epidemic outbreaks. The diagnosis of DENV is challenging mainly due to the circulation of new viruses with remarkable similarities, such as Zika (ZIKV) that may cause fetal microcephaly. DENV affects 390 million people per year, but these numbers may be higher due to the underreported and misclassified cases. Recently, the NS1 nonstructural protein has been described in serum and urine of DENV and ZIKV patients, suggesting its use as a biomarker for screening since a negative NS1 sample confirms the absence of these infections. Herein, a label-free immunosensor comprising an assembled nanostructured thin film of carbon nanotube-ethylenediamine is described. The advantage of in situ electrosynthesis of polymer film is to allow major control of thickness and conductivity, in addition to designing the reactive groups for functionalization. A quartz crystal microbalance system was used to estimate the thickness of the polymeric film obtained. The anti-NS1 monoclonal antibodies were immobilized to carbon nanotubes by covalent linkage, permitting a high stability during measurements. Analytical responses to NS1 were obtained by differential pulse voltammetry (DPV), showing a linear range from 20 to 800 ng mL-1 and reproducibility of 3.0%, with a limit of detection (LOD) of 6.8 ng mL- 1. This immunosensor was capable of detecting ZIKV and DENV NS1 in spiked urine and real serum in a clinical range.Graphical abstract.
Collapse
Affiliation(s)
- Priscila D Mendonça
- Biomedical Engineering Laboratory, Federal University of Pernambuco, Recife, PE, 50670-901, Brazil
| | - Lorenna K B Santos
- Biomedical Engineering Laboratory, Federal University of Pernambuco, Recife, PE, 50670-901, Brazil
| | - Marcos V Foguel
- Biomedical Engineering Laboratory, Federal University of Pernambuco, Recife, PE, 50670-901, Brazil
| | - Marco A B Rodrigues
- Electronic Department, Federal University of Pernambuco, Recife, PE, 50740-550, Brazil
| | - Marli T Cordeiro
- Department of Virology and Experimental Therapy, Oswaldo Cruz Foundation - FIOCRUZ, Aggeu Magalhães Institute, Recife, PE, 50670-420, Brazil
| | - Luís M Gonçalves
- Institute of Chemistry, University of São Paulo, São Paulo, SP, 5508-000, Brazil
| | - Ernesto T A Marques
- Department of Infectious Diseases and Microbiology, University of Pittsburgh, Center for Vaccine Research, Pittsburgh, PA, 15261, USA
| | - Rosa F Dutra
- Biomedical Engineering Laboratory, Federal University of Pernambuco, Recife, PE, 50670-901, Brazil.
| |
Collapse
|
5
|
Marbán-Castro E, Arrieta GJ, Martínez MJ, González R, Bardají A, Menéndez C, Mattar S. High Seroprevalence of Antibodies against Arboviruses among Pregnant Women in Rural Caribbean Colombia in the Context of the Zika Virus Epidemic. Antibodies (Basel) 2020; 9:antib9040056. [PMID: 33096597 PMCID: PMC7709128 DOI: 10.3390/antib9040056] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 08/27/2020] [Accepted: 09/09/2020] [Indexed: 12/03/2022] Open
Abstract
Mosquito-borne viruses such as dengue (DENV), chikungunya (CHIKV), and Zika (ZIKV) have spread in recent decades. We aimed to assess seroprevalence of arboviral infections in pregnant women living in Cereté, Caribbean Colombia. In 2016 a cross-sectional facility-based sero-survey study was performed among pregnant women (N = 90). Most of them (66%) reported at least one symptom or sign compatible with arboviral infection over the previous 15 days. All screened women had a positive IgG for DENV, 89% for ZIKV, and 82% for CHIKV. One woman tested positive for ZIKV IgM. This study shows the high exposure among pregnant women to arboviruses in endemic areas, shown by the high seroprevalence of past arboviral infections. Given the evidence on the potential risks of these arboviral infections on pregnancy and infant outcomes, these results highlight the need for continuous epidemiological surveillance of arboviral diseases, particularly among those most of risk of their harmful consequences.
Collapse
Affiliation(s)
- Elena Marbán-Castro
- ISGlobal, Hospital Clínic, Universitat de Barcelona, 08036 Barcelona, Spain; (M.J.M.); (R.G.); (A.B.); (C.M.)
- Consorcio de Investigación Biomédica en Red de Epidemiología y Salud Pública (CIBERESP), 28029 Madrid, Spain
- Correspondence: ; Tel.: +34-93-227-5400 (ext. 4142)
| | - Germán J. Arrieta
- Corporación Universitaria del Caribe (CECAR), Grupo de Salud Pública, Sincelejo 700001, Colombia;
- Clínica Salud Social, Sincelejo 700001, Colombia;
| | - Miguel J. Martínez
- ISGlobal, Hospital Clínic, Universitat de Barcelona, 08036 Barcelona, Spain; (M.J.M.); (R.G.); (A.B.); (C.M.)
- Consorcio de Investigación Biomédica en Red de Epidemiología y Salud Pública (CIBERESP), 28029 Madrid, Spain
| | - Raquel González
- ISGlobal, Hospital Clínic, Universitat de Barcelona, 08036 Barcelona, Spain; (M.J.M.); (R.G.); (A.B.); (C.M.)
- Consorcio de Investigación Biomédica en Red de Epidemiología y Salud Pública (CIBERESP), 28029 Madrid, Spain
| | - Azucena Bardají
- ISGlobal, Hospital Clínic, Universitat de Barcelona, 08036 Barcelona, Spain; (M.J.M.); (R.G.); (A.B.); (C.M.)
- Consorcio de Investigación Biomédica en Red de Epidemiología y Salud Pública (CIBERESP), 28029 Madrid, Spain
- Centro de Investigação em Saúde de Manhiça (CISM), Manhiça 1929, Mozambique
| | - Clara Menéndez
- ISGlobal, Hospital Clínic, Universitat de Barcelona, 08036 Barcelona, Spain; (M.J.M.); (R.G.); (A.B.); (C.M.)
- Consorcio de Investigación Biomédica en Red de Epidemiología y Salud Pública (CIBERESP), 28029 Madrid, Spain
- Centro de Investigação em Saúde de Manhiça (CISM), Manhiça 1929, Mozambique
| | - Salim Mattar
- Clínica Salud Social, Sincelejo 700001, Colombia;
- Instituto de Investigaciones Biológicas del Trópico, Universidad de Córdoba, Montería 230002, Colombia
| |
Collapse
|