Boháč P, Apostolopoulos V, Marcián P, Tomáš T, Mahdal M, Návrat T. Computational modeling of bone allograft reconstruction following femoral shaft tumor resection: Investigating the impact of supplementary plate fixation. PLoS One 2025; 20:e0316719. [PMID: 39913461 PMCID: PMC11801617 DOI: 10.1371/journal.pone.0316719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Accepted: 12/15/2024] [Indexed: 02/09/2025] Open
Abstract
BACKGROUND AND OBJECTIVE The use of bone allograft reconstructions after tumor resection can introduce significant complications. Stable fixation is required to decrease the incidence of mechanical complications of segmental bone allografts. The purpose of the present study is to compare plating fixation methods of diaphyseal allografts after intercalary resection of the femur. METHODS We created four defined fixation models using plates and/or intramedullary polymethylmethacrylate (PMMA) to simulate typical bone tumor resection with intercalary allograft reconstruction. One angularly stable plate (DFP) with 13 locking screws and fresh frozen allografts (labeled "I") were used for bone reconstruction. Three modified reconstructions were created: "II" included a supplementary plate (SP) with four locking screws, "III" was augmented with intramedullary PMMA in the allograft, and "IV" combined intramedullary PMMA and both plates. We applied a load model that simulates partial weight bearing on the lower limb to simulate the load during postoperative rehabilitation. RESULTS The highest stress in the DFP occurred at the allograft-bone transition, with variant IV reaching 297 MPa. PMMA augmentation reduced median interfragmentary motion (IFM) and sliding distances, with variant III achieving the lowest distal sliding distance (0.9 μm) in the distal area. Supplementary plate fixation reduced maximal and median proximal IFM distances (86.9 μm in variant II vs. 116.0 μm in variant I) but increased sliding distances (23.7 μm in variant II vs. 0.6 μm in variant I). CONCLUSIONS PMMA augmentation reduces IFM and sliding distances, enhancing rigidity, particularly in the distal area. Supplementary plate fixation decreases IFM distances in the proximal area but increases sliding distances in the same region. Variants III and IV demonstrate lower IFM and sliding distances in the distal area overall. Variant III shows very low sliding distances in both distal and proximal areas. Variant IV combines improved firmness with slightly higher stress levels.
Collapse
Affiliation(s)
- Petr Boháč
- Faculty of Mechanical Engineering, Institute of Solid Mechanics, Mechatronics and Biomechanics, University of Technology, Brno, Czech Republic
| | - Vasileios Apostolopoulos
- First Department of Orthopaedic Surgery, St. Anne’s University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Petr Marcián
- Faculty of Mechanical Engineering, Institute of Solid Mechanics, Mechatronics and Biomechanics, University of Technology, Brno, Czech Republic
| | - Tomáš Tomáš
- First Department of Orthopaedic Surgery, St. Anne’s University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Michal Mahdal
- First Department of Orthopaedic Surgery, St. Anne’s University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Tomáš Návrat
- Faculty of Mechanical Engineering, Institute of Solid Mechanics, Mechatronics and Biomechanics, University of Technology, Brno, Czech Republic
| |
Collapse
|
2
|
Liu D, Miao Z, Zhang W, Liu C, Du L, Zhu Y, Luo Y, Zheng W, Zhou J, Liu P, Li X, Li M. Biomechanical analysis of different techniques for residual bone defect from tibial plateau bone cyst in total knee arthroplasty. Front Bioeng Biotechnol 2024; 12:1498882. [PMID: 39539692 PMCID: PMC11557455 DOI: 10.3389/fbioe.2024.1498882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2024] [Accepted: 10/18/2024] [Indexed: 11/16/2024] Open
Abstract
Background In patients with tibial plateau bone cysts undergoing total knee arthroplasty (TKA), bone defects commonly occur following tibial plateau resection. Current strategies for addressing these defects include bone grafting, bone cement filling, and the cement-screw technique. However, there remains no consensus on the optimal approach to achieve the best surgical outcomes. This study aims to evaluate the most effective repair method for residual bone defects following tibial plateau bone cyst repair during TKA from a biomechanical perspective. Methods The treatment options for tibial plateau bone defects were classified into four categories: no treatment, cancellous bone filling, bone cement filling, and the cement-screw technique. Finite-element analysis (FEA) was employed to evaluate stress distribution and displacement across the models for each treatment group. In addition, static compression mechanical tests were used to assess the displacement of the models within each group. Results FEA results indicate that when employing the cement-screw technique to repair tibial plateau bone defects, the maximum stress on the prosthesis and the cement below the prosthesis is minimized, while the maximum stress on the cancellous bone is maximized. And the displacement of each component is minimized. Biomechanical tests results further demonstrate that the displacement of the model is minimized when utilizing the cement-screw technique for tibial plateau bone defects. Conclusion Using cement-screw technique in treating residual tibial bone defects due to bone cysts in TKA offers optimal biomechanical advantages.
Collapse
Affiliation(s)
- Dehua Liu
- Department of Orthopaedics, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Zhuang Miao
- Department of Orthopaedics, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
| | - Wenfei Zhang
- Psychological Department, Qilu Hospital of Shandong University Dezhou Hospital, Dezhou, Shandong, China
| | - Chuanwen Liu
- Department of Orthopaedics, Qilu Hospital of Shandong University Dezhou Hospital, Dezhou, Shandong, China
| | - Longzhuo Du
- Department of Orthopaedics, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Yuanlong Zhu
- Department of Orthopaedics, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Yange Luo
- Department of Orthopaedics, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Weibo Zheng
- Department of Orthopaedics, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Jianli Zhou
- Nuclear Medicine Department, Qilu Hospital of Shandong University Dezhou Hospital, Dezhou, Shandong, China
| | - Peilai Liu
- Department of Orthopaedics, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Orthopaedics, Qilu Hospital of Shandong University Dezhou Hospital, Dezhou, Shandong, China
| | - Xuezhou Li
- Department of Orthopaedics, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Ming Li
- Department of Orthopaedics, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Orthopaedics, Qilu Hospital of Shandong University Dezhou Hospital, Dezhou, Shandong, China
| |
Collapse
|
3
|
Pais A, Moreira C, Belinha J. The Biomechanical Analysis of Tibial Implants Using Meshless Methods: Stress and Bone Tissue Remodeling Analysis. DESIGNS 2024; 8:28. [DOI: 10.3390/designs8020028] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
Abstract
Total knee arthroplasty (TKA) stands out as one of the most widely employed surgical procedures, establishing itself as the preferred method for addressing advanced osteoarthritis of the knee. However, current knee prostheses require refined design solutions. This research work focuses on a computational analysis of both the mechanical behavior of a knee joint implant and the bone remodeling process in the tibia following implantation. This research study delves into how specific design parameters, particularly the stem geometry, impact the prosthesis’s performance. Utilizing a computed tomography scan of a tibia, various TKA configurations were simulated to conduct analyses employing advanced discretization techniques, such as the finite element method (FEM) and the radial point interpolation method (RPIM). The findings reveal that the introduction of the implant leads to a marginal increase in the stress values within the tibia, accompanied by a reduction in the displacement field values. The insertion of the longest tested implant increased the maximum stress from 5.0705 MPa to 6.1584 MPa, leading to a displacement reduction from 0.016 mm to 0.0142 mm. Finally, by combining the FEM with a bone remodeling algorithm, the bone remodeling process of the tibia due to an implant insertion was simulated.
Collapse
Affiliation(s)
- Ana Pais
- FEUP—Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
- INEGI—Institute of Science and Innovation in Mechanical and Industrial Engineering, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
| | - Catarina Moreira
- ISEP—School of Engineering, Polytechnic University of Porto, Rua Dr. António Bernardino de Almeida, 431, 4249-015 Porto, Portugal
| | - Jorge Belinha
- INEGI—Institute of Science and Innovation in Mechanical and Industrial Engineering, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
- ISEP—School of Engineering, Polytechnic University of Porto, Rua Dr. António Bernardino de Almeida, 431, 4249-015 Porto, Portugal
| |
Collapse
|
4
|
Apostolopoulos V, Boháč P, Marcián P, Nachtnebl L, Mahdal M, Pazourek L, Tomáš T. Biomechanical comparison of all-polyethylene total knee replacement and its metal-backed equivalent on periprosthetic tibia using the finite element method. J Orthop Surg Res 2024; 19:153. [PMID: 38396020 PMCID: PMC10893603 DOI: 10.1186/s13018-024-04631-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 02/15/2024] [Indexed: 02/25/2024] Open
Abstract
BACKGROUND Total knee arthroplasty (TKA) with all-polyethylene tibial (APT) components has shown comparable survivorship and clinical outcomes to that with metal-backed tibial (MBT). Although MBT is more frequently implanted, APT equivalents are considered a low-cost variant for elderly patients. A biomechanical analysis was assumed to be suitable to compare the response of the periprosthetic tibia after implantation of TKA NexGen APT and MBT equivalent. METHODS A standardised load model was used representing the highest load achieved during level walking. The geometry and material models were created using computed tomography data. In the analysis, a material model was created that represents a patient with osteopenia. RESULTS The equivalent strain distribution in the models of cancellous bone with an APT component showed values above 1000 με in the area below the medial tibial section, with MBT component were primarily localised in the stem tip area. For APT variants, the microstrain values in more than 80% of the volume were in the range from 300 to 1500 με, MBT only in less than 64% of the volume. CONCLUSION The effect of APT implantation on the periprosthetic tibia was shown as equal or even superior to that of MBT despite maximum strain values occurring in different locations. On the basis of the strain distribution, the state of the bone tissue was analysed to determine whether bone tissue remodelling or remodelling would occur. Following clinical validation, outcomes could eventually modify the implant selection criteria and lead to more frequent implantation of APT components.
Collapse
Affiliation(s)
- Vasileios Apostolopoulos
- First Department of Orthopaedic Surgery, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Petr Boháč
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Faculty of Mechanical Engineering, University of Technology, Brno, Czech Republic
| | - Petr Marcián
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Faculty of Mechanical Engineering, University of Technology, Brno, Czech Republic
| | - Luboš Nachtnebl
- First Department of Orthopaedic Surgery, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Michal Mahdal
- First Department of Orthopaedic Surgery, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Lukáš Pazourek
- First Department of Orthopaedic Surgery, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Tomáš Tomáš
- First Department of Orthopaedic Surgery, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic.
| |
Collapse
|
5
|
Yan M, Liang T, Zhao H, Bi Y, Wang T, Yu T, Zhang Y. Model Properties and Clinical Application in the Finite Element Analysis of Knee Joint: A Review. Orthop Surg 2024; 16:289-302. [PMID: 38174410 PMCID: PMC10834231 DOI: 10.1111/os.13980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 11/21/2023] [Accepted: 12/04/2023] [Indexed: 01/05/2024] Open
Abstract
The knee is the most complex joint in the human body, including bony structures like the femur, tibia, fibula, and patella, and soft tissues like menisci, ligaments, muscles, and tendons. Complex anatomical structures of the knee joint make it difficult to conduct precise biomechanical research and explore the mechanism of movement and injury. The finite element model (FEM), as an important engineering analysis technique, has been widely used in many fields of bioengineering research. The FEM has advantages in the biomechanical analysis of objects with complex structures. Researchers can use this technology to construct a human knee joint model and perform biomechanical analysis on it. At the same time, finite element analysis can effectively evaluate variables such as stress, strain, displacement, and rotation, helping to predict injury mechanisms and optimize surgical techniques, which make up for the shortcomings of traditional biomechanics experimental research. However, few papers introduce what material properties should be selected for each anatomic structure of knee FEM to meet different research purposes. Based on previous finite element studies of the knee joint, this paper summarizes various modeling strategies and applications, serving as a reference for constructing knee joint models and research design.
Collapse
Affiliation(s)
- Mingyue Yan
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Ting Liang
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Haibo Zhao
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Yanchi Bi
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Tianrui Wang
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Tengbo Yu
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
- Department of Orthopedic Surgery, Qingdao Hospital, University of Health and Rehabilitation Sciences (Qingdao Municipal Hospital), Qingdao, China
| | - Yingze Zhang
- Department of Orthopedics, The Third Hospital of Hebei Medical University, Shijiazhuang, China
| |
Collapse
|
6
|
Kovács K, Váncsa S, Agócs G, Harnos A, Hegyi P, Weninger V, Baross K, Kovács B, Soós G, Kocsis G. Anisotropy, Anatomical Region, and Additional Variables Influence Young's Modulus of Bone: A Systematic Review and Meta-Analysis. JBMR Plus 2023; 7:e10835. [PMID: 38130752 PMCID: PMC10731124 DOI: 10.1002/jbm4.10835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Revised: 08/09/2023] [Accepted: 09/25/2023] [Indexed: 12/23/2023] Open
Abstract
The importance of finite element analysis (FEA) is growing in orthopedic research, especially in implant design. However, Young's modulus (E) values, one of the most fundamental parameters, can range across a wide scale. Therefore, our study aimed to identify factors influencing E values in human bone specimens. We report our systematic review and meta-analysis based on the recommendation of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guideline. We conducted the analysis on November 21, 2021. We included studies investigating healthy human bone specimens and reported on E values regarding demographic data, specimen characteristics, and measurement specifics. In addition, we included study types reporting individual specimen measurements. From the acquired data, we created a cohort in which we performed an exploratory data analysis that included the explanatory variables selected by random forest and regression trees methods, and the comparison of groups using independent samples Welch's t test. A total of 756 entries were included from 48 articles. Eleven different bones of the human body were included in these articles. The range of E values is between 0.008 and 33.7 GPa. The E values were most heavily influenced by the cortical or cancellous type of bone tested. Measuring method (compression, tension, bending, and nanoindentation), the anatomical region within a bone, the position of the bone within the skeleton, and the bone specimen size had a decreasing impact on the E values. Bone anisotropy, specimen condition, patient age, and sex were selected as important variables considering the value of E. On the basis of our results, E values of a bone change with bone characteristics, measurement techniques, and demographic variables. Therefore, the evaluation of FEA should be performed after the standardization of in vitro measurement protocol. © 2023 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Krisztián Kovács
- Department of OrthopaedicsSemmelweis UniversityBudapestHungary
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
| | - Szilárd Váncsa
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
- Institute for Translational Medicine, Szentágothai Research Centre, Medical SchoolUniversity of PécsPécsHungary
- Division of Pancreatic Diseases, Heart and Vascular CenterSemmelweis UniversityBudapestHungary
| | - Gergely Agócs
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
- Department of Biophysics and Radiation BiologySemmelweis UniversityBudapestHungary
| | - Andrea Harnos
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
- Department of BiostatisticsUniversity of Veterinary MedicineBudapestHungary
| | - Péter Hegyi
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
- Institute for Translational Medicine, Szentágothai Research Centre, Medical SchoolUniversity of PécsPécsHungary
- Division of Pancreatic Diseases, Heart and Vascular CenterSemmelweis UniversityBudapestHungary
| | - Viktor Weninger
- Department of OrthopaedicsSemmelweis UniversityBudapestHungary
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
| | - Katinka Baross
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
| | - Bence Kovács
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
| | - Gergely Soós
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
| | - György Kocsis
- Department of OrthopaedicsSemmelweis UniversityBudapestHungary
- Centre for Translational MedicineSemmelweis UniversityBudapestHungary
| |
Collapse
|
7
|
Apostolopoulos V, Nachtnebl L, Mahdal M, Pazourek L, Boháč P, Janíček P, Tomáš T. Clinical outcomes and survival comparison between NexGen all-poly and its metal-backed equivalent in total knee arthroplasty. INTERNATIONAL ORTHOPAEDICS 2023; 47:2207-2213. [PMID: 37069277 PMCID: PMC10439055 DOI: 10.1007/s00264-023-05772-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Accepted: 03/10/2023] [Indexed: 04/19/2023]
Abstract
PURPOSE This study aims to compare total knee replacement (TKA) with NexGen All-Poly (APT) and NexGen Metal-Backed (MBT) in terms of implant survivorship, reasons leading to implant failure and functional results of defined age categories. METHODS A single-centre, retrospective evaluation of 812 patients who underwent knee replacement with NexGen CR between 2005 and 2021, comparing a modern congruent APT component to a modular MBT equivalent component using a similar surgical technique at a notable mean follow-up duration. Implant survival, functional outcomes using the Knee Society Score and range of motion were evaluated and compared in different age categories. RESULTS Of the 812 NexGen CR TKAs performed at our institution, 410 (50.4%) used APT components and 402 (49.6%) MBT components. The survival rate of NexGen APT was 97.1% and that of NexGen MBT was 93.2% (p = 0.36). Removal of the implant occurred overall in 15 cases, for MBT in ten cases, and for APT in four cases. The FS was proved to be significantly higher when APT components were implanted in younger patients than for MBT (p = 0.005). A similar range of motion between the components was recorded (p = 0.1926). CONCLUSION Under defined conditions, we measured the clinical results of implants from a single manufacturer implanted in a single department using a similar surgical technique. Considering the limitations, we suggest that all-polyethylene tibial components are equal or even superior to metal-backed ones across the examined age categories.
Collapse
Affiliation(s)
- Vasileios Apostolopoulos
- First Department of Orthopaedic Surgery, St. Anne’s University Hospital and Faculty of Medicine, Masaryk University, FN u Sv Anny Brne, Pekarska 53, Brno, 60200 Czechia
| | - Luboš Nachtnebl
- First Department of Orthopaedic Surgery, St. Anne’s University Hospital and Faculty of Medicine, Masaryk University, FN u Sv Anny Brne, Pekarska 53, Brno, 60200 Czechia
| | - Michal Mahdal
- First Department of Orthopaedic Surgery, St. Anne’s University Hospital and Faculty of Medicine, Masaryk University, FN u Sv Anny Brne, Pekarska 53, Brno, 60200 Czechia
| | - Lukáš Pazourek
- First Department of Orthopaedic Surgery, St. Anne’s University Hospital and Faculty of Medicine, Masaryk University, FN u Sv Anny Brne, Pekarska 53, Brno, 60200 Czechia
| | - Petr Boháč
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Faculty of Mechanical Engineering, University of Technology, Brno, Czechia
| | - Pavel Janíček
- First Department of Orthopaedic Surgery, St. Anne’s University Hospital and Faculty of Medicine, Masaryk University, FN u Sv Anny Brne, Pekarska 53, Brno, 60200 Czechia
| | - Tomáš Tomáš
- First Department of Orthopaedic Surgery, St. Anne’s University Hospital and Faculty of Medicine, Masaryk University, FN u Sv Anny Brne, Pekarska 53, Brno, 60200 Czechia
| |
Collapse
|