1
|
Prostate volume prediction on MRI: tools, accuracy and variability. Eur Radiol 2022; 32:4931-4941. [PMID: 35169895 DOI: 10.1007/s00330-022-08554-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 12/20/2021] [Accepted: 12/21/2021] [Indexed: 11/04/2022]
Abstract
OBJECTIVE A reliable estimation of prostate volume (PV) is essential to prostate cancer management. The objective of our multi-rater study was to compare intra- and inter-rater variability of PV from manual planimetry and ellipsoid formulas. METHODS Forty treatment-naive patients who underwent prostate MRI were selected from a local database. PV and corresponding PSA density (PSAd) were estimated on 3D T2-weighted MRI (3 T) by 7 independent radiologists using the traditional ellipsoid formula (TEF), the newer biproximate ellipsoid formula (BPEF), and the manual planimetry method (MPM) used as ground truth. Intra- and inter-rater variability was calculated using the mixed model-based intraclass correlation coefficient (ICC). RESULTS Mean volumes were 67.00 (± 36.61), 66.07 (± 35.03), and 64.77 (± 38.27) cm3 with the TEF, BPEF, and MPM methods, respectively. Both TEF and BPEF overestimated PV relative to MPM, with the former presenting significant differences (+ 1.91 cm3, IQ = [- 0.33 cm3, 5.07 cm3], p val = 0.03). Both intra- (ICC > 0.90) and inter-rater (ICC > 0.90) reproducibility were excellent. MPM had the highest inter-rater reproducibility (ICC = 0.999). Inter-rater PV variation led to discrepancies in classification according to the clinical criterion of PSAd > 0.15 ng/mL for 2 patients (5%), 7 patients (17.5%), and 9 patients (22.5%) when using MPM, TEF, and BPEF, respectively. CONCLUSION PV measurements using ellipsoid formulas and MPM are highly reproducible. MPM is a robust method for PV assessment and PSAd calculation, with the lowest variability. TEF showed a high degree of concordance with MPM but a slight overestimation of PV. Precise anatomic landmarks as defined with the BPEF led to a more accurate PV estimation, but also to a higher variability. KEY POINTS • Manual planimetry used for prostate volume estimation is robust and reproducible, with the lowest variability between readers. • Ellipsoid formulas are accurate and reproducible but with higher variability between readers. • The traditional ellipsoid formula tends to overestimate prostate volume.
Collapse
|
2
|
Correlation of in-vivo imaging with histopathology: A review. Eur J Radiol 2021; 144:109964. [PMID: 34619617 DOI: 10.1016/j.ejrad.2021.109964] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 08/26/2021] [Accepted: 09/17/2021] [Indexed: 11/21/2022]
Abstract
Despite tremendous advancements in in vivo imaging modalities, there remains substantial uncertainty with respect to tumor delineation on in these images. Histopathology remains the gold standard for determining the extent of malignancy, with in vivo imaging to histopathologic correlation enabling spatial comparisons. In this review, the steps necessary for successful imaging to histopathologic correlation are described, including in vivo imaging, resection, fixation, specimen sectioning (sectioning technique, securing technique, orientation matching, slice matching), microtome sectioning and staining, correlation (including image registration) and performance evaluation. The techniques used for each of these steps are also discussed. Hundreds of publications from the past 20 years were surveyed, and 62 selected for detailed analysis. For these 62 publications, each stage of the correlative pathology process (and the sub-steps of specimen sectioning) are listed. A statistical analysis was conducted based on 19 studies that reported target registration error as their performance metric. While some methods promise greater accuracy, they may be expensive. Due to the complexity of the processes involved, correlative pathology studies generally include a small number of subjects, which hinders advanced developments in this field.
Collapse
|
3
|
Wasserman NF, Niendorf E, Spilseth B. Measurement of Prostate Volume with MRI (A Guide for the Perplexed): Biproximate Method with Analysis of Precision and Accuracy. Sci Rep 2020; 10:575. [PMID: 31953425 PMCID: PMC6969030 DOI: 10.1038/s41598-019-57046-x] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Accepted: 12/17/2019] [Indexed: 12/14/2022] Open
Abstract
To review the anatomic basis of prostate boundary selection on T2-weighted magnetic resonance imaging (MRI). To introduce an alternative 3D ellipsoid measuring technique that maximizes precision, report the intra- and inter-observer reliability, and to advocate it's use for research involving multiple observers. We demonstrate prostate boundary anatomy using gross pathology and MRI examples. This provides background for selecting key boundary marks when measuring prostate volume. An alternative ellipsoid volume method is then proposed using these boundaries in an attempt to improve inter-observer precision. An IRB approved retrospective study of 140 patients with elevated serum prostate specific antigen levels and/or abnormal digital rectal examinations was done with T2-weighted MRI applying a new (Biproximate) technique. Measurements were made by 2 examiners, correlated with each other for inter-observer precision and correlated with an expert observer for accuracy. Correlation statistics, linear regression analysis, and tests of means were applied using p ≤ 0.05 as the threshold for significance. Inter-observer correlation (precision) was 0.95 between observers. Correlation between these observers and the expert (accuracy) was 0.94 and 0.97 respectively. Intra-observer correlation for the expert was 0.98. Means for inter-rater reliability and accuracy were all the same (p = 0.001). We conclude that using more precise reproducible landmarks with biproximate technique, precision and accuracy of total prostate volume is found to be demonstrated.
Collapse
Affiliation(s)
- Neil F Wasserman
- Department of Radiology, University of Minnesota, Mayo Mail Code 292, 420 Delaware Street S.E, Minneapolis, MN, 55455 (612) 626-3343, USA.
| | - Eric Niendorf
- Department of Radiology, University of Minnesota, Mayo Mail Code 292, 420 Delaware Street S.E, Minneapolis, MN, 55455 (612) 626-3343, USA
| | - Benjamin Spilseth
- Department of Radiology, University of Minnesota, Mayo Mail Code 292, 420 Delaware Street S.E, Minneapolis, MN, 55455 (612) 626-3343, USA
| |
Collapse
|
4
|
Whitaker J, Neji R, Byrne N, Puyol-Antón E, Mukherjee RK, Williams SE, Chubb H, O’Neill L, Razeghi O, Connolly A, Rhode K, Niederer S, King A, Tschabrunn C, Anter E, Nezafat R, Bishop MJ, O’Neill M, Razavi R, Roujol S. Improved co-registration of ex-vivo and in-vivo cardiovascular magnetic resonance images using heart-specific flexible 3D printed acrylic scaffold combined with non-rigid registration. J Cardiovasc Magn Reson 2019; 21:62. [PMID: 31597563 PMCID: PMC6785908 DOI: 10.1186/s12968-019-0574-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2018] [Accepted: 09/02/2019] [Indexed: 01/01/2023] Open
Abstract
BACKGROUND Ex-vivo cardiovascular magnetic resonance (CMR) imaging has played an important role in the validation of in-vivo CMR characterization of pathological processes. However, comparison between in-vivo and ex-vivo imaging remains challenging due to shape changes occurring between the two states, which may be non-uniform across the diseased heart. A novel two-step process to facilitate registration between ex-vivo and in-vivo CMR was developed and evaluated in a porcine model of chronic myocardial infarction (MI). METHODS Seven weeks after ischemia-reperfusion MI, 12 swine underwent in-vivo CMR imaging with late gadolinium enhancement followed by ex-vivo CMR 1 week later. Five animals comprised the control group, in which ex-vivo imaging was undertaken without any support in the LV cavity, 7 animals comprised the experimental group, in which a two-step registration optimization process was undertaken. The first step involved a heart specific flexible 3D printed scaffold generated from in-vivo CMR, which was used to maintain left ventricular (LV) shape during ex-vivo imaging. In the second step, a non-rigid co-registration algorithm was applied to align in-vivo and ex-vivo data. Tissue dimension changes between in-vivo and ex-vivo imaging were compared between the experimental and control group. In the experimental group, tissue compartment volumes and thickness were compared between in-vivo and ex-vivo data before and after non-rigid registration. The effectiveness of the alignment was assessed quantitatively using the DICE similarity coefficient. RESULTS LV cavity volume changed more in the control group (ratio of cavity volume between ex-vivo and in-vivo imaging in control and experimental group 0.14 vs 0.56, p < 0.0001) and there was a significantly greater change in the short axis dimensions in the control group (ratio of short axis dimensions in control and experimental group 0.38 vs 0.79, p < 0.001). In the experimental group, prior to non-rigid co-registration the LV cavity contracted isotropically in the ex-vivo condition by less than 20% in each dimension. There was a significant proportional change in tissue thickness in the healthy myocardium (change = 29 ± 21%), but not in dense scar (change = - 2 ± 2%, p = 0.034). Following the non-rigid co-registration step of the process, the DICE similarity coefficients for the myocardium, LV cavity and scar were 0.93 (±0.02), 0.89 (±0.01) and 0.77 (±0.07) respectively and the myocardial tissue and LV cavity volumes had a ratio of 1.03 and 1.00 respectively. CONCLUSIONS The pattern of the morphological changes seen between the in-vivo and the ex-vivo LV differs between scar and healthy myocardium. A 3D printed flexible scaffold based on the in-vivo shape of the LV cavity is an effective strategy to minimize morphological changes in the ex-vivo LV. The subsequent non-rigid registration step further improved the co-registration and local comparison between in-vivo and ex-vivo data.
Collapse
Affiliation(s)
- John Whitaker
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
- Siemens Healthcare Limited, Frimley, UK
| | - Nicholas Byrne
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
- Medical Physics, Guy’s and St. Thomas’ NHS Foundation Trust, London, UK
| | - Esther Puyol-Antón
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Rahul K. Mukherjee
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Steven E. Williams
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Henry Chubb
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Louisa O’Neill
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Orod Razeghi
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Adam Connolly
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Kawal Rhode
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Steven Niederer
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Andrew King
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Cory Tschabrunn
- Cardiology Department, University of Pennsylvania, Philadelphia, PA USA
| | - Elad Anter
- Cardiology Department, Beth Israel Deaconess Medical Centre / Harvard Medical School, Boston, MA USA
| | - Reza Nezafat
- Cardiology Department, Beth Israel Deaconess Medical Centre / Harvard Medical School, Boston, MA USA
| | - Martin J. Bishop
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Mark O’Neill
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Reza Razavi
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| | - Sébastien Roujol
- School of Biomedical Engineering and Imaging Sciences, King’s College, London, Fourth Floor Lambeth Wing, St Thomas’ Hospital, London, SE1 7EH UK
| |
Collapse
|
5
|
Christie DRH, Sharpley CF. How Accurately Can Prostate Gland Imaging Measure the Prostate Gland Volume? Results of a Systematic Review. Prostate Cancer 2019; 2019:6932572. [PMID: 30941221 PMCID: PMC6420971 DOI: 10.1155/2019/6932572] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Accepted: 02/04/2019] [Indexed: 01/08/2023] Open
Abstract
AIM The measurement of the volume of the prostate gland can have an influence on many clinical decisions. Various imaging methods have been used to measure it. Our aim was to conduct the first systematic review of their accuracy. METHODS The literature describing the accuracy of imaging methods for measuring the prostate gland volume was systematically reviewed. Articles were included if they compared volume measurements obtained by medical imaging with a reference volume measurement obtained after removal of the gland by radical prostatectomy. Correlation and concordance statistics were summarised. RESULTS 28 articles describing 7768 patients were identified. The imaging methods were ultrasound, computed tomography, and magnetic resonance imaging (US, CT, and MRI). Wide variations were noted but most articles about US and CT provided correlation coefficients that lay between 0.70 and 0.90, while those describing MRI seemed slightly more accurate at 0.80-0.96. When concordance was reported, it was similar; over- and underestimation of the prostate were variably reported. Most studies showed evidence of at least moderate bias and the quality of the studies was highly variable. DISCUSSION The reported correlations were moderate to high in strength indicating that imaging is sufficiently accurate when quantitative measurements of prostate gland volume are required. MRI was slightly more accurate than the other methods.
Collapse
Affiliation(s)
- David R. H. Christie
- GenesisCare, Inland Drive, Tugun, QLD 4224, Australia
- Brain-Behaviour Research Group, University of New England, Armidale, NSW 2350, Australia
| | | |
Collapse
|
6
|
Sun Y, Reynolds HM, Parameswaran B, Wraith D, Finnegan ME, Williams S, Haworth A. Multiparametric MRI and radiomics in prostate cancer: a review. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2019; 42:3-25. [PMID: 30762223 DOI: 10.1007/s13246-019-00730-z] [Citation(s) in RCA: 74] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Accepted: 01/22/2019] [Indexed: 12/30/2022]
Abstract
Multiparametric MRI (mpMRI) is an imaging modality that combines anatomical MR imaging with one or more functional MRI sequences. It has become a versatile tool for detecting and characterising prostate cancer (PCa). The traditional role of mpMRI was confined to PCa staging, but due to the advanced imaging techniques, its role has expanded to various stages in clinical practises including tumour detection, disease monitor during active surveillance and sequential imaging for patient follow-up. Meanwhile, with the growing speed of data generation and the increasing volume of imaging data, it is highly demanded to apply computerised methods to process mpMRI data and extract useful information. Hence quantitative analysis for imaging data using radiomics has become an emerging paradigm. The application of radiomics approaches in prostate cancer has not only enabled automatic localisation of the disease but also provided a non-invasive solution to assess tumour biology (e.g. aggressiveness and the presence of hypoxia). This article reviews mpMRI and its expanding role in PCa detection, staging and patient management. Following that, an overview of prostate radiomics will be provided, with a special focus on its current applications as well as its future directions.
Collapse
Affiliation(s)
- Yu Sun
- University of Sydney, Sydney, Australia. .,Peter MacCallum Cancer Centre, Melbourne, Australia.
| | | | | | - Darren Wraith
- Queensland University of Technology, Brisbane, Australia
| | - Mary E Finnegan
- Imperial College Healthcare NHS Trust, London, UK.,Imperial College London, London, UK
| | | | | |
Collapse
|
7
|
Accurate validation of ultrasound imaging of prostate cancer: a review of challenges in registration of imaging and histopathology. J Ultrasound 2018; 21:197-207. [PMID: 30062440 PMCID: PMC6113189 DOI: 10.1007/s40477-018-0311-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Accepted: 07/11/2018] [Indexed: 01/20/2023] Open
Abstract
As the development of modalities for prostate cancer (PCa) imaging advances, the challenge of accurate registration between images and histopathologic ground truth becomes more pressing. Localization of PCa, rather than detection, requires a pixel-to-pixel validation of imaging based on histopathology after radical prostatectomy. Such a registration procedure is challenging for ultrasound modalities; not only the deformations of the prostate after resection have to be taken into account, but also the deformation due to the employed transrectal probe and the mismatch in orientation between imaging planes and pathology slices. In this work, we review the latest techniques to facilitate accurate validation of PCa localization in ultrasound imaging studies and extrapolate a general strategy for implementation of a registration procedure.
Collapse
|
8
|
Re: Magnetic Resonance Imaging Underestimation of Prostate Cancer Geometry: Use of Patient Specific Molds to Correlate Images with Whole Mount Pathology: A. Priester, S. Natarajan, P. Khoshnoodi, D. J. Margolis, S. S. Raman, R. E. Reiter, J. Huang, W. Grundfest and L. S. Marks J Urol 2017;197:320-326. J Urol 2017; 198:1436-1437. [PMID: 28888772 DOI: 10.1016/j.juro.2017.07.086] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/18/2017] [Indexed: 11/24/2022]
|
9
|
Wildeboer RR, Schalk SG, Demi L, Wijkstra H, Mischi M. Three-dimensional histopathological reconstruction as a reliable ground truth for prostate cancer studies. Biomed Phys Eng Express 2017. [DOI: 10.1088/2057-1976/aa7073] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
10
|
Bourne RM, Bailey C, Johnston EW, Pye H, Heavey S, Whitaker H, Siow B, Freeman A, Shaw GL, Sridhar A, Mertzanidou T, Hawkes DJ, Alexander DC, Punwani S, Panagiotaki E. Apparatus for Histological Validation of In Vivo and Ex Vivo Magnetic Resonance Imaging of the Human Prostate. Front Oncol 2017; 7:47. [PMID: 28393049 PMCID: PMC5364138 DOI: 10.3389/fonc.2017.00047] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2017] [Accepted: 03/08/2017] [Indexed: 01/30/2023] Open
Abstract
This article describes apparatus to aid histological validation of magnetic resonance imaging studies of the human prostate. The apparatus includes a 3D-printed patient-specific mold that facilitates aligned in vivo and ex vivo imaging, in situ tissue fixation, and tissue sectioning with minimal organ deformation. The mold and a dedicated container include MRI-visible landmarks to enable consistent tissue positioning and minimize image registration complexity. The inclusion of high spatial resolution ex vivo imaging aids in registration of in vivo MRI and histopathology data.
Collapse
Affiliation(s)
- Roger M. Bourne
- Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, Sydney, NSW, Australia
| | - Colleen Bailey
- Centre for Medical Image Computing, University College London, London, UK
| | | | - Hayley Pye
- Centre for Molecular Intervention, University College London, London, UK
| | - Susan Heavey
- Centre for Molecular Intervention, University College London, London, UK
| | - Hayley Whitaker
- Centre for Molecular Intervention, University College London, London, UK
| | - Bernard Siow
- Centre for Advanced Biomedical Imaging, University College London, London, UK
| | - Alex Freeman
- Department of Research Pathology, University College London, London, UK
| | - Greg L. Shaw
- Division of Surgery and Interventional Science, University College London, London, UK
- Department of Urology, University College London Hospitals, London, UK
| | - Ashwin Sridhar
- Division of Surgery and Interventional Science, University College London, London, UK
- Department of Urology, University College London Hospitals, London, UK
| | - Thomy Mertzanidou
- Centre for Medical Image Computing, University College London, London, UK
| | - David J. Hawkes
- Centre for Medical Image Computing, University College London, London, UK
| | | | - Shonit Punwani
- Centre for Medical Imaging, University College London, London, UK
| | | |
Collapse
|
11
|
Evaluation of tongue squamous cell carcinoma resection margins using ex-vivo MR. Int J Comput Assist Radiol Surg 2017; 12:821-828. [PMID: 28130702 PMCID: PMC5420007 DOI: 10.1007/s11548-017-1524-6] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2016] [Accepted: 01/06/2017] [Indexed: 01/13/2023]
Abstract
Purpose Purpose of this feasibility study was (1) to evaluate whether application of ex-vivo 7T MR of the resected tongue specimen containing squamous cell carcinoma may provide information on the resection margin status and (2) to evaluate the research and developmental issues that have to be solved for this technique to have the beneficial impact on clinical outcome that we expect: better oncologic and functional outcomes, better quality of life, and lower costs. Methods We performed a non-blinded validation of ex-vivo 7T MR to detect the tongue squamous cell carcinoma and resection margin in 10 fresh tongue specimens using histopathology as gold standard. Results In six of seven specimens with a histopathologically determined invasion depth of the tumor of \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$${\ge }3$$\end{document}≥3 mm, the tumor could be recognized on MR, with a resection margin within a 2 mm range as compared to histopathology. In three specimens with an invasion depth of \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$${<}1$$\end{document}<1 mm, the tumor was not visible on MR. Technical limitations mainly included scan time, image resolution, and the fact that we used a less available small-bore 7T MR machine. Conclusion Ex-vivo 7T probably will have a low negative predictive value but a high positive predictive value, meaning that in tumors thicker than a few millimeters we expect to be able to predict whether the resection margin is too small. A randomized controlled trial needs to be performed to show our hypothesis: better oncologic and functional outcomes, better quality of life, and lower costs.
Collapse
|
12
|
Radtke JP, Teber D, Hohenfellner M, Hadaschik BA. The current and future role of magnetic resonance imaging in prostate cancer detection and management. Transl Androl Urol 2016; 4:326-41. [PMID: 26816833 PMCID: PMC4708229 DOI: 10.3978/j.issn.2223-4683.2015.06.05] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Purpose Accurate detection of clinically significant prostate cancer (PC) and correct risk attribution are essential to individually counsel men with PC. Multiparametric MRI (mpMRI) facilitates correct localization of index lesions within the prostate and MRI-targeted prostate biopsy (TPB) helps to avoid the shortcomings of conventional biopsy such as false-negative results or underdiagnosis of aggressive PC. In this review we summarize the different sequences of mpMRI, characterize the possibilities of incorporating MRI in the biopsy workflow and outline the performance of targeted and systematic cores in significant cancer detection. Furthermore, we outline the potential of MRI in patients undergoing active surveillance (AS) and in the pre-operative setting. Materials and methods An electronic MEDLINE/PubMed search up to February 2015 was performed. English language articles were reviewed for inclusion ability and data were extracted, analyzed and summarized. Results Targeted biopsies significantly outperform conventional systematic biopsies in the detection of significant PC and are not inferior when compared to transperineal saturation biopsies. MpMRI can detect index lesions in app. 90% of cases as compared to prostatectomy specimen. The diagnostic performance of biparametric MRI (T2w + DWI) is not inferior to mpMRI, offering options to diminish cost- and time-consumption. Since app 10% of significant lesions are still MRI-invisible, systematic cores seem to be necessary. In-bore biopsy and MRI/TRUS-fusion-guided biopsy tend to be superior techniques compared to cognitive fusion. In AS, mpMRI avoids underdetection of significant PC and confirms low-risk disease accurately. In higher-risk disease, pre-surgical MRI can change the clinically-based surgical plan in up to a third of cases. Conclusions mpMRI and targeted biopsies are able to detect significant PC accurately and mitigate insignificant PC detection. As long as the negative predictive value (NPV) is still imperfect, systematic cores should not be omitted for optimal staging of disease. The potential to correctly classify aggressiveness of disease in AS patients and to guide and plan prostatectomy is evolving.
Collapse
Affiliation(s)
- Jan Philipp Radtke
- 1 Department of Urology, Heidelberg University Hospital, Heidelberg, Germany ; 2 Department of Radiology, German Cancer Research Center, Heidelberg, Germany
| | - Dogu Teber
- 1 Department of Urology, Heidelberg University Hospital, Heidelberg, Germany ; 2 Department of Radiology, German Cancer Research Center, Heidelberg, Germany
| | - Markus Hohenfellner
- 1 Department of Urology, Heidelberg University Hospital, Heidelberg, Germany ; 2 Department of Radiology, German Cancer Research Center, Heidelberg, Germany
| | - Boris A Hadaschik
- 1 Department of Urology, Heidelberg University Hospital, Heidelberg, Germany ; 2 Department of Radiology, German Cancer Research Center, Heidelberg, Germany
| |
Collapse
|
13
|
Validation of an Improved Patient-Specific Mold Design for Registration of In-vivo MRI and Histology of the Prostate. CLINICAL IMAGE-BASED PROCEDURES. TRANSLATIONAL RESEARCH IN MEDICAL IMAGING 2016. [DOI: 10.1007/978-3-319-46472-5_5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
|
14
|
Reynolds HM, Williams S, Zhang A, Chakravorty R, Rawlinson D, Ong CS, Esteva M, Mitchell C, Parameswaran B, Finnegan M, Liney G, Haworth A. Development of a registration framework to validate MRI with histology for prostate focal therapy. Med Phys 2015; 42:7078-89. [DOI: 10.1118/1.4935343] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
|