1
|
Hata T, Takayoshi R, Sugihara M, Koyanagi A, Miyake T. Transvaginal SlowflowHD for embryonic and fetal hearts: human cardiac development in first trimester of pregnancy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2025; 65:662-666. [PMID: 39101993 DOI: 10.1002/uog.29095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 07/13/2024] [Accepted: 07/16/2024] [Indexed: 08/06/2024]
Affiliation(s)
- T Hata
- Department of Obstetrics and Gynecology, Miyake Clinic, Minami-ku, Okayama, Japan
- Department of Perinatology and Gynecology, Kagawa University Graduate School of Medicine, Miki, Kagawa, Japan
| | - R Takayoshi
- Department of Obstetrics and Gynecology, Miyake Clinic, Minami-ku, Okayama, Japan
- Department of Perinatology and Gynecology, Kagawa University Graduate School of Medicine, Miki, Kagawa, Japan
| | - M Sugihara
- Department of Obstetrics and Gynecology, Miyake Clinic, Minami-ku, Okayama, Japan
- Department of Obstetrics and Gynecology, Kawasaki Medical School, Kurashiki, Okayama, Japan
| | - A Koyanagi
- Department of Obstetrics and Gynecology, Miyake Clinic, Minami-ku, Okayama, Japan
| | - T Miyake
- Department of Obstetrics and Gynecology, Miyake Clinic, Minami-ku, Okayama, Japan
- Department of Perinatology and Gynecology, Kagawa University Graduate School of Medicine, Miki, Kagawa, Japan
| |
Collapse
|
2
|
Pincham V, McLennan A, Forsey J, Mogra R. Simplified First-Trimester Fetal Cardiac Screening Protocol for Low-Risk Pregnancies: Enhancing Efficiency and Accuracy. Australas J Ultrasound Med 2025; 28:e70000. [PMID: 40236880 PMCID: PMC11995031 DOI: 10.1002/ajum.70000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2024] [Revised: 12/14/2024] [Accepted: 01/19/2025] [Indexed: 04/17/2025] Open
Abstract
Introduction Congenital heart defects (CHDs) are among the most prevalent congenital anomalies and are frequently detected in pregnancies classified as low-risk, rather than in high-risk groups. Advancements in ultrasound technology have heightened the emphasis on first-trimester fetal cardiac screening. However, due to the small size of the fetal heart at this stage, significant challenges persist, underscoring the need for simplified and reproducible protocols that can be effectively applied on a population-wide scale. Methods This paper describes a screening approach centred on the four-chamber view (4CV) and three-vessel tracheal view (3VTV) with colour Doppler imaging. This includes optimisation of ultrasound machine settings and the use of transabdominal and transvaginal approaches to enhance visualisation. Results Evidence demonstrates a CHD detection rate of 76% in low-risk populations, with a 95% success rate in obtaining the necessary views. Discussion and Conclusion Operator expertise and familiarity with cardiac anomalies are critical for accurate detection. The early identification of CHDs enables informed decision-making regarding pregnancy management. A simplified protocol for first-trimester cardiac screening offers a promising tool for the early identification of CHDs, enabling timely referral and intervention. To optimise detection rates and clinical outcomes, continuous professional education and systematic auditing processes are indispensable for practitioners performing early fetal cardiac screening.
Collapse
Affiliation(s)
| | - Andrew McLennan
- Sydney Ultrasound for WomenSydneyAustralia
- University of SydneySydneyAustralia
| | | | - Ritu Mogra
- Sydney Ultrasound for WomenSydneyAustralia
- Royal Prince Alfred HospitalSydneyAustralia
| |
Collapse
|
3
|
Gómez-Montes E, Herraiz I, Villalain C, Galindo A. Second trimester echocardiography. Best Pract Res Clin Obstet Gynaecol 2025; 100:102592. [PMID: 40132464 DOI: 10.1016/j.bpobgyn.2025.102592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Accepted: 02/24/2025] [Indexed: 03/27/2025]
Abstract
Fetal echocardiography involves a comprehensive cardiac assessment aiming to make a complete structural examination of the heart as well as to detect signs of cardiovascular adaptation to different insults. For the former, this assessment entails expert's evaluation of the anatomy of the heart including additional views beyond the five axial views used in cardiac screening examinations and always complemented with colour and pulsed Doppler. Echocardiography may accurately diagnose most congenital heart defects in fetal life, which enables adjusting the perinatal management. For the latter, echocardiography encompasses cardiac morphometric assessment to identify signs of cardiac remodeling indicative of cardiac adaptation in structure, shape, and size in response to underlying diseases, and cardiac functional assessment to detect signs of systolic and/or diastolic dysfunction. The most used parameters to study the systolic function (stroke volume, cardiac output, ejection fraction, fractional shortening, and mitral and tricuspid annular plane systolic excursion), diastolic function (characteristics of flow in the precordial veins and through the atrioventricular valves) and global myocardial function (myocardial performance index) will be discussed in this review.
Collapse
Affiliation(s)
- Enery Gómez-Montes
- Fetal Medicine Unit. Obstetrics and Gynecology Department. Hospital Universitario 12 de Octubre. Complutense University, Madrid. Instituto de Investigación del Hospital 12 de Octubre (imas12). Primary Care Interventions to Prevent Maternal and Child Chronic Diseases of Perinatal and Developmental Origin (RICORS network), RD21/0012/0024, Madrid, Spain.
| | - Ignacio Herraiz
- Fetal Medicine Unit. Obstetrics and Gynecology Department. Hospital Universitario 12 de Octubre. Complutense University, Madrid. Instituto de Investigación del Hospital 12 de Octubre (imas12). Primary Care Interventions to Prevent Maternal and Child Chronic Diseases of Perinatal and Developmental Origin (RICORS network), RD21/0012/0024, Madrid, Spain.
| | - Cecilia Villalain
- Fetal Medicine Unit. Obstetrics and Gynecology Department. Hospital Universitario 12 de Octubre. Complutense University, Madrid. Instituto de Investigación del Hospital 12 de Octubre (imas12). Primary Care Interventions to Prevent Maternal and Child Chronic Diseases of Perinatal and Developmental Origin (RICORS network), RD21/0012/0024, Madrid, Spain.
| | - Alberto Galindo
- Fetal Medicine Unit. Obstetrics and Gynecology Department. Hospital Universitario 12 de Octubre. Complutense University, Madrid. Instituto de Investigación del Hospital 12 de Octubre (imas12). Primary Care Interventions to Prevent Maternal and Child Chronic Diseases of Perinatal and Developmental Origin (RICORS network), RD21/0012/0024, Madrid, Spain.
| |
Collapse
|
4
|
Popa AI, Cernea N, Marinaș MC, Comănescu MC, Sîrbu OC, Popa DG, Pătru L, Pădureanu V, Pătru CL. Ultrasound Screening in the First and Second Trimester of Pregnancy for the Detection of Fetal Cardiac Anomalies in a Low-Risk Population. Diagnostics (Basel) 2025; 15:769. [PMID: 40150110 PMCID: PMC11941630 DOI: 10.3390/diagnostics15060769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2025] [Revised: 03/13/2025] [Accepted: 03/15/2025] [Indexed: 03/29/2025] Open
Abstract
Background/Objectives: Congenital heart disease (CHD) is the most common birth defect, an important cause of morbidity and mortality, with a reported prevalence of 5-12 per 1000 live births. The aim of our study was to identify the role of fetal morphological ultrasound examination in the first and second trimester of pregnancy in the detection of fetal congenital cardiac anomalies in a low-risk population. Methods: We performed a retrospective study in a tertiary fetal medicine center in Emergency Hospital Craiova, Romania. The longitudinal analysis combined first- and second-trimester screening using improved ultrasound protocols. Our study evaluated 8944 pregnant women with singleton pregnancies in a 6-year period between January 2018 and December 2023. All ultrasound examinations were performed using a standard extended protocol according to the main guidelines' recommendations for the detection of fetal anomalies. Results: In the first trimester of pregnancy, 37 cases with cardiac anomalies were diagnosed. Thirteen of these cases were associated with genetic anomalies (Down syndrome-eight cases, Edwards syndrome-four cases, Turner syndrome-one case). Some of these pregnancies were associated with at least one of the minor ultrasound markers (inverted ductus venosus, abnormal flow in the tricuspid valve, presence of choroid plexus cysts, absent/hypoplastic nasal bone). In the second trimester of pregnancy, 17 cases of cardiac anomalies were diagnosed. From these cases, one was associated with genetic anomalies (DiGeorge Syndrome), and one case developed hydrops and delivered prematurely in the early third trimester. Conclusions: Ultrasound screening for the detection of congenital heart disease is feasible early in pregnancy, but some anomalies would be obvious later in pregnancy. An early diagnosis using an extended ultrasound protocol, genetic testing, and a multidisciplinary evaluation would improve the prognosis and the overall survival rate by delivering in a tertiary center that allows for rapid cardiac surgery in dedicated cases.
Collapse
Affiliation(s)
- Aura Iuliana Popa
- Doctoral School, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania;
| | - Nicolae Cernea
- Department of Obstetrics and Gynecology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (N.C.); (O.C.S.); (C.L.P.)
| | - Marius Cristian Marinaș
- Department of Human Anatomy, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania;
| | - Maria Cristina Comănescu
- Department of Human Anatomy, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania;
| | - Ovidiu Costinel Sîrbu
- Department of Obstetrics and Gynecology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (N.C.); (O.C.S.); (C.L.P.)
| | - Dragoș George Popa
- Department of Plastic Surgery, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
| | - Larisa Pătru
- Department 9, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania;
| | - Vlad Pădureanu
- Department of Internal Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania;
| | - Ciprian Laurențiu Pătru
- Department of Obstetrics and Gynecology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (N.C.); (O.C.S.); (C.L.P.)
| |
Collapse
|
5
|
Hata T, Konishi M, Koyanagi A, Miyagi Y, Miyake T. Embryonic and Fetal Heart Development Before 12 Weeks of Gestation. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2025; 44:301-321. [PMID: 39431605 DOI: 10.1002/jum.16605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Revised: 09/25/2024] [Accepted: 10/05/2024] [Indexed: 10/22/2024]
Abstract
OBJECTIVE To assess embryonic and fetal cardiac growth and development using transvaginal 2-dimensional sonography before 12 weeks of gestation. METHODS Transvaginal scans for first-trimester dating were performed for 131 normal fetuses at 8-11 + 6 weeks of gestation. The basal-apical length (BAL), transverse length (TL), cardiac circumference (ECC), embryonic cardiac area (ECA), global sphericity index (GSI), and cardio-thoracic area ratio (CTAR) were able to be obtained in 105 normal embryos and fetuses. RESULTS Nomograms for several cardiac parameters including BAL, TL, ECC, ECA, GSI, and CTAR were constructed. BAL, TL, ECC, and ECA increased curvilinearly with advancing gestation (R2 = 0.97406, 0.980396, 0.978359, and 0.920705, respectively, P < .001). GSI (mean, 1.14; SD, 0.10) and CTAR (mean, 15.7%; SD, 3.3%) values were constant at 8-11 + 6 weeks of gestation. There were significant curvilinear correlations between BAL, TL, ECC, and ECA, and crown-rump length (CRL) (R2 = 0.975976, 0.983482, 0.980673, and 0.929936, respectively, P < .001). GSI and CTAR values were not changed with the increase of CRL during this period. CONCLUSION Our results provide nomograms for several cardiac parameters which may improve the understanding of embryonic and fetal cardiac growth and development prior to 12 weeks of gestation.
Collapse
Affiliation(s)
- Toshiyuki Hata
- Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan
- Department of Perinatology and Gynecology, Kagawa University Graduate School of Medicine, Miki, Japan
| | - Miyu Konishi
- Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan
| | - Aya Koyanagi
- Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan
| | - Yasunari Miyagi
- Department of Gynecology, Miyake Ofuku Clinic, Okayama, Japan
| | - Takahito Miyake
- Department of Obstetrics and Gynecology, Miyake Clinic, Okayama, Japan
- Department of Perinatology and Gynecology, Kagawa University Graduate School of Medicine, Miki, Japan
| |
Collapse
|
6
|
Rittey L, Davidson H, Hornberger LK, Eckersley L, Boehme C, McBrien A. Fetal Echocardiography From 10 to 15 Weeks of Gestation-Reliability, Genetic Associations, and Outcomes. J Am Soc Echocardiogr 2024; 37:1123-1132.e2. [PMID: 39218368 DOI: 10.1016/j.echo.2024.08.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 08/22/2024] [Accepted: 08/26/2024] [Indexed: 09/04/2024]
Abstract
INTRODUCTION There is increasing demand for accurate early fetal cardiac disease (FCD). We assessed the accuracy of early fetal echo (EFE) conducted in our high-volume fetal cardiac program and reviewed the spectrum of FCD, associated genetic anomalies, and outcomes encountered. METHODS We identified all EFEs performed from 10+0 to 15+6 weeks of gestation from 2009 to 2021. We compared findings at EFE to fetal echo at ≥18+0 weeks or autopsy and documented genetic testing results for all FCD cases. For those with discrepancy between EFE and later exam, the discrepancy impact was reviewed. A score was used to quantify the anatomy assessed. RESULTS A total of 1,662 EFEs were performed in 1,387 pregnancies; all but 41 were considered diagnostic. Fetal cardiac disease was diagnosed at EFE in 130, including 101 major, 12 minor, 13 other FCD, and 4 arrhythmias. In 14/130 with FCD, endovaginal imaging was undertaken, which increased the score (1.6/9 vs 3.5/9; P = .049). Thirty-five of 130 had repeat EFE, which increased the score (5.2/9 vs 7.4/9, P < .0001). Fetal loss occurred before confirmation of FCD in 16 and termination in 64, and 11 were lost to follow-up. Thirty-nine had autopsy and/or fetal echo ≥18+0: 35 had FCD confirmed, and 4 had resolution. Of the 35 confirmed FCD, 27 had no, 7 minor, and 1 major change. Of 1,489 with normal EFE, later echo demonstrated FCD in 14: 3 major and 11 minor. In 16, FCD evolved, including 4 arrhythmias and 12 with progressive FCD. Sensitivity, specificity, and positive and negative predictive values of EFE in identifying major FCD were 92.9%, 100%, 100%, and 99.7%, respectively. In cases with FCD, 85.4% had genetic testing, of whom 71% (60.8% of the total) had abnormal results. CONCLUSIONS In our experience, EFE permits accurate diagnosis and exclusion of most FCD. Endovaginal imaging and repeat EFE studies improved the ability to visualize structures adequately.
Collapse
Affiliation(s)
- Leila Rittey
- Fetal and Neonatal Cardiology Programs, Division of Cardiology, Department of Pediatrics, University of Alberta, Edmonton Clinic Health Academy, Edmonton, Alberta, Canada; Women's and Children's Health Research Institute, University of Alberta, Edmonton Clinic Health Academy, Edmonton, Alberta, Canada; Department of Congenital Heart Disease, Leeds General Infirmary, Leeds, United Kingdom
| | - Hannah Davidson
- Fetal and Neonatal Cardiology Programs, Division of Cardiology, Department of Pediatrics, University of Alberta, Edmonton Clinic Health Academy, Edmonton, Alberta, Canada; Women's and Children's Health Research Institute, University of Alberta, Edmonton Clinic Health Academy, Edmonton, Alberta, Canada
| | - Lisa K Hornberger
- Fetal and Neonatal Cardiology Programs, Division of Cardiology, Department of Pediatrics, University of Alberta, Edmonton Clinic Health Academy, Edmonton, Alberta, Canada; Women's and Children's Health Research Institute, University of Alberta, Edmonton Clinic Health Academy, Edmonton, Alberta, Canada; Department of Obstetrics and Gynecology, University of Alberta, Royal Alexandra Hospital, Edmonton, Alberta, Canada
| | - Luke Eckersley
- Fetal and Neonatal Cardiology Programs, Division of Cardiology, Department of Pediatrics, University of Alberta, Edmonton Clinic Health Academy, Edmonton, Alberta, Canada; Women's and Children's Health Research Institute, University of Alberta, Edmonton Clinic Health Academy, Edmonton, Alberta, Canada
| | - Cleighton Boehme
- Fetal and Neonatal Cardiology Programs, Division of Cardiology, Department of Pediatrics, University of Alberta, Edmonton Clinic Health Academy, Edmonton, Alberta, Canada
| | - Angela McBrien
- Fetal and Neonatal Cardiology Programs, Division of Cardiology, Department of Pediatrics, University of Alberta, Edmonton Clinic Health Academy, Edmonton, Alberta, Canada; Women's and Children's Health Research Institute, University of Alberta, Edmonton Clinic Health Academy, Edmonton, Alberta, Canada.
| |
Collapse
|
7
|
Nuñez Gallegos F, Moon-Grady AJ. Early Heart Checks: Harnessing Fetal Echocardiography, Genetic Insights, and the Role of Transvaginal Cardiac Imaging in Clinical Practice. J Am Soc Echocardiogr 2024; 37:1133-1135. [PMID: 39401731 DOI: 10.1016/j.echo.2024.10.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2024] [Accepted: 10/09/2024] [Indexed: 12/07/2024]
|
8
|
Liu J, Liu D, Yin H, Wang B, Wang Y, Ran L, Wang S, Zhang G, Chen F, Yu D. Slow flow HD and traditional CDFI technologies in identifying pulmonary veins in the first trimester. Arch Gynecol Obstet 2024; 310:855-861. [PMID: 38280055 DOI: 10.1007/s00404-023-07352-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 12/17/2023] [Indexed: 01/29/2024]
Abstract
OBJECTIVE This study aims to assess the feasibility and effectiveness of color doppler flow imaging (CDFI) technology and the Slow Flow HD imaging technique in identifying fetal pulmonary veins (PVs) in the first trimester (11-13 + 6 weeks), and further explore the factors affecting fetal pulmonary vein identification in early pregnancy. METHODS Echocardiography and scanning of PVs were performed in 240 normal singleton fetuses in early pregnancy by using CDFI and slow flow HD techniques, to compare the ability of two methods to identify the PVs. Slow Flow HD technology was used to further investigate the difference of PVs identification at different gestational ages [group I (11-11 + 6 weeks), group II (12-12 + 6 weeks), group III (13-13 + 6 weeks)] and with different maternal body mass indices (BMI) (≥ 25 and < 25). In 31 cases of 240 fetuses, transvaginal ultrasonography was added due to maternal habitus or significant retroversion of the uterus, and the difference in PVs identification between transabdominal and transvaginal examination was analyzed. RESULTS Successful PVs identification rates via CDFI and Slow Flow HD were 32.0% and 88.3%, respectively (p < 0.05). The identification rate of at least one and two pulmonary veins in Slow Flow HD was 88.3% and 76.2%, and all four pulmonary veins in 11.6% (p < 0.05). The identification rate of group I, II and III were 76.4%, 88.9% and 96.0%, respectively. The identification rate was 45.1% in the transabdominal ultrasound group and 83.8% in the transvaginal ultrasound group. The identification rate was 62.5% in the BMI ≥ 25 group and 94.7% in the BMI < 25 group (p < 0.05). CONCLUSIONS Slow Flow HD can detect PVs in early pregnancy more often than using CDFI. Slow Flow HD is a feasible and effective imaging technique for evaluating PVs in early pregnancy.
Collapse
Affiliation(s)
- Jing Liu
- Departments of Ultrasound, Maternal and Child Health Care Hospital of Shandong Province, No. 238, Jingshi East Road, Lixia District, Jinan, 250000, Shandong Province, China
| | - Dequan Liu
- Departments of Ultrasound, Maternal and Child Health Care Hospital of Shandong Province, No. 238, Jingshi East Road, Lixia District, Jinan, 250000, Shandong Province, China
| | - Hong Yin
- Departments of Ultrasound, Maternal and Child Health Care Hospital of Shandong Province, No. 238, Jingshi East Road, Lixia District, Jinan, 250000, Shandong Province, China.
| | - Bei Wang
- Department of Ultrasound, The First Affiliated Hospital of Shandong First Medical University, No. 16766, Jingshi Road, Lixia District, Jinan, 250014, Shandong Province, China.
| | - Yanjie Wang
- Departments of Ultrasound, Maternal and Child Health Care Hospital of Shandong Province, No. 238, Jingshi East Road, Lixia District, Jinan, 250000, Shandong Province, China
| | - Lingqiang Ran
- Department of Emergency, Shandong Provincial Rehabilitation Hospital, Jinan, 250109, China
| | - Shulin Wang
- Departments of Ultrasound, Jinan Third People's Hospital, Jinan, 250132, China
| | - Ge Zhang
- Departments of Ultrasound, Maternal and Child Health Care Hospital of Shandong Province, No. 238, Jingshi East Road, Lixia District, Jinan, 250000, Shandong Province, China
| | - Fang Chen
- Department of Ultrasound, The Second Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan, 250001, China
| | - Dongyi Yu
- Department of Key Laboratory of Birth Defect Prevention and Genetic Medicine of Shandong Health Commission, Maternal and Child Health Care Hospital of Shandong Province, Jinan, 250000, China
| |
Collapse
|
9
|
Odackal NJ, Crume M, Naik T, Stiver C. Cardiac Development and Related Clinical Considerations. Neoreviews 2024; 25:e401-e414. [PMID: 38945970 DOI: 10.1542/neo.25-7-e401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 02/27/2024] [Accepted: 03/06/2024] [Indexed: 07/02/2024]
Abstract
The anatomy, physiology, and hemodynamics of the premature heart vary along the range of gestational ages cared for in neonatal intensive care units, from 22 weeks to term gestation. Clinical management of the preterm neonate should account for this heterogenous development. This requires an understanding of the impact of ex utero stressors on immature and disorganized cardiac tissue, the different state of hemodynamics across intracardiac shunts impacting the natural transition from fetal to neonatal life, and the effects of intensive pharmacologic and non-pharmacologic interventions that have systemic consequences influencing cardiac function. This article provides a review of the increasing but still limited body of literature on the anatomy, hemodynamics, and electrophysiology of the preterm heart with relevant clinical considerations.
Collapse
Affiliation(s)
- Namrita J Odackal
- Department of Pediatrics, The Ohio State University College of Medicine, Columbus, OH
- Division of Neonatology, Nationwide Children's Hospital, Columbus, OH
| | - Mary Crume
- Division of Neonatology, Nationwide Children's Hospital, Columbus, OH
| | - Tanvi Naik
- Center for Perinatal Research, Abigail Wexner Research Institute at Nationwide Children's Hospital, Columbus, OH
| | - Corey Stiver
- Department of Pediatrics, The Ohio State University College of Medicine, Columbus, OH
- Division of Cardiology, Nationwide Children's Hospital, Columbus, OH
| |
Collapse
|
10
|
Carrasco D, Guedes-Martins L. Cardiac Axis in Early Gestation and Congenital Heart Disease. Curr Cardiol Rev 2024; 20:CCR-EPUB-137797. [PMID: 38279755 PMCID: PMC11071675 DOI: 10.2174/011573403x264660231210162041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 09/06/2023] [Accepted: 10/17/2023] [Indexed: 01/28/2024] Open
Abstract
Congenital heart defects represent the most common structural anomalies observed in the fetal population, and they are often associated with significant morbidity and mortality. The fetal cardiac axis, which indicates the orientation of the heart in relation to the chest wall, is formed by the angle between the anteroposterior axis of the chest and the interventricular septum of the heart. Studies conducted during the first trimester have demonstrated promising outcomes with respect to the applicability of cardiac axis measurement in fetuses with congenital heart defects as well as fetuses with extracardiac and chromosomal anomalies, which may result in improved health outcomes and reduced healthcare costs. The main aim of this review article was to highlight the cardiac axis as a reliable and powerful marker for the detection of congenital heart defects during early gestation, including defects that would otherwise remain undetectable through the conventional four-chamber view.
Collapse
Affiliation(s)
- D. Carrasco
- Instituto de Ciências Biomédicas Abel Salazar, University of Porto, 4050-313 Porto, Portugal
- Centro de Medicina Fetal, Medicina Fetal Porto, Serviço de Obstetrícia - Centro Materno Infantil do Norte, Porto 4099-001, Portugal
| | - L. Guedes-Martins
- Instituto de Ciências Biomédicas Abel Salazar, University of Porto, 4050-313 Porto, Portugal
- Centro de Medicina Fetal, Medicina Fetal Porto, Serviço de Obstetrícia - Centro Materno Infantil do Norte, Porto 4099-001, Portugal
- Centro Hospitalar Universitário do Porto EPE, Centro Materno Infantil do Norte, Departamento da Mulher e da Medicina Reprodutiva, Largo Prof. Abel Salazar, 4099-001 Porto, Portugal
- Unidade de Investigação e Formação-Centro Materno Infantil do Norte, 4099-001 Porto, Portugal
- Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Porto, 4200-319, Portugal
| |
Collapse
|
11
|
Portela Dias J, Guedes-Martins L. Fetal Pulmonary Venous Return: From Basic Research to the Clinical Value of Doppler Assessment. Pediatr Cardiol 2023; 44:1419-1437. [PMID: 37505268 PMCID: PMC10435640 DOI: 10.1007/s00246-023-03244-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 07/20/2023] [Indexed: 07/29/2023]
Abstract
The fetal pulmonary circulation represents less than 25% of the fetal cardiac output. In comparison with the pulmonary arteries, studies on pulmonary veins are few and limited, and many questions remain to be answered. The literature reports that pulmonary veins play an important role in regulating vascular flow, forming an active segment of the pulmonary circulation. The development of more sophisticated ultrasonography technology has allowed the investigation of the extraparenchymal pulmonary veins and their waveform. The recognition of the pulmonary vein anatomy in echocardiography is important for the diagnosis of anomalous pulmonary venous connections, with a significant impact on prognosis. On the other hand, the identification of the normal pulmonary vein waveform seems to be a reliable way to study left heart function, with potential applicability in fetal and maternal pathology. Thus, the goal of this narrative review was to provide a clinically oriented perspective of the available literature on this topic.
Collapse
Affiliation(s)
- J Portela Dias
- Instituto de Ciências Biomédicas Abel Salazar, University of Porto, 4050-313, Porto, Portugal.
- Departamento da Mulher e da Medicina Reprodutiva, Centro Materno Infantil do Norte, Centro Hospitalar e Universitário de Santo António, Largo da Maternidade Júlio Dinis 45, 4050-651, Porto, Portugal.
- Unidade de Investigação e Formação - Centro Materno Infantil do Norte, 4050-651, Porto, Portugal.
| | - L Guedes-Martins
- Instituto de Ciências Biomédicas Abel Salazar, University of Porto, 4050-313, Porto, Portugal
- Departamento da Mulher e da Medicina Reprodutiva, Centro Materno Infantil do Norte, Centro Hospitalar e Universitário de Santo António, Largo da Maternidade Júlio Dinis 45, 4050-651, Porto, Portugal
- Unidade de Investigação e Formação - Centro Materno Infantil do Norte, 4050-651, Porto, Portugal
- Instituto de Investigação e Inovação em Saúde, Universidade do Porto, 4200-135, Porto, Portugal
| |
Collapse
|
12
|
Ling W, Wu Q, Guo S, Li S, Ma H, Huang B, Zeng L, Dang T, Liu M, Qiu X, Weng Z. Four-section approach of fetal congenital heart disease at 11-13 +6 weeks. Front Cardiovasc Med 2023; 10:1206042. [PMID: 37692039 PMCID: PMC10483229 DOI: 10.3389/fcvm.2023.1206042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Accepted: 08/03/2023] [Indexed: 09/12/2023] Open
Abstract
Objective The objective of the study is to explore the value of the four-section approach in detecting fetal heart defects in the first trimester (11-13+6 weeks), analyze the reasons for the inconsistency between the results of ultrasound examination in the first trimester and subsequent verification, and describe the most common abnormal flow patterns of four sections. Materials and methods Between June 2019 and June 2021, a prenatal four-section approach (upper abdominal transverse section, four-chamber section, three vessel-trachea section, and bilateral subclavian artery section) with verification results in early pregnancy was analyzed. Results In total, 9,533 fetuses were included. Finally, 176 fetuses with congenital heart disease (CHD), containing 34 types, were identified. The total detection rate of cardiac abnormalities was 1.85%. 102 cases were accurately diagnosed by ultrasonography during early pregnancy. A total of 74 fetuses who had inconsistent results between fetal cardiac ultrasound and verification in early pregnancy were reported, of which the cases of 22 fetuses were inconsistent due to disease evolution and progression and the cases of 52 fetuses were inconsistent due to missed diagnosis and misdiagnosis. The sensitivity, specificity, positive predictive value, and negative predictive value of the four-section approach were 67.05%, 99.96%, 96.58%, and 99.33%, respectively. In this study, a total of 30 abnormal ultrasonic imaging patterns in four sections were summarized. Conclusion We confirmed that the four-section approach in early pregnancy has a good diagnostic efficacy for fetal CHD. Intrauterine evolution of the fetal heart, missed diagnosis, and misdiagnosis are the reasons for the inconsistency between the results of early pregnancy ultrasound and subsequent verification. This study also presents the abnormal imaging patterns of four scan sections of CHD in early pregnancy, which are instructive for the rapid identification and diagnosis of CHD in the first trimester.
Collapse
Affiliation(s)
- Wen Ling
- Department of Medical Ultrasonics, Fujian Maternity and Child Health Care Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
| | - Qiumei Wu
- Department of Medical Ultrasonics, Fujian Maternity and Child Health Care Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
| | - Shan Guo
- Department of Medical Ultrasonics, Fujian Maternity and Child Health Care Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
| | - Shangqing Li
- Department of Medical Ultrasonics, Fujian Maternity and Child Health Care Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
| | - Hong Ma
- Department of Pathology, Fujian Maternity and Child Health Care Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
| | - Biying Huang
- Department of Medical Ultrasonics, Fujian Maternity and Child Health Care Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
| | - Liqin Zeng
- Department of Medical Ultrasonics, Fujian Maternity and Child Health Care Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
| | - Tingting Dang
- Department of Medical Ultrasonics, Fujian Maternity and Child Health Care Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
| | - Min Liu
- Department of Medical Ultrasonics, Fujian Maternity and Child Health Care Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
| | - Xiuqing Qiu
- Department of Obstetrics & Gynecology, Fujian Maternity and Child Health Care Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
| | - Zongjie Weng
- Department of Medical Ultrasonics, Fujian Maternity and Child Health Care Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China
| |
Collapse
|
13
|
Moon-Grady AJ, Donofrio MT, Gelehrter S, Hornberger L, Kreeger J, Lee W, Michelfelder E, Morris SA, Peyvandi S, Pinto NM, Pruetz J, Sethi N, Simpson J, Srivastava S, Tian Z. Guidelines and Recommendations for Performance of the Fetal Echocardiogram: An Update from the American Society of Echocardiography. J Am Soc Echocardiogr 2023; 36:679-723. [PMID: 37227365 DOI: 10.1016/j.echo.2023.04.014] [Citation(s) in RCA: 65] [Impact Index Per Article: 32.5] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Affiliation(s)
| | - Mary T Donofrio
- Children's National Hospital, Washington, District of Columbia
| | | | | | - Joe Kreeger
- Children's Healthcare of Atlanta, Atlanta, Georgia
| | - Wesley Lee
- Baylor College of Medicine, Houston, Texas
| | | | - Shaine A Morris
- Baylor College of Medicine, Houston, Texas; Texas Children's Hospital, Houston, Texas
| | - Shabnam Peyvandi
- University of California, San Francisco, San Francisco, California
| | | | - Jay Pruetz
- Children's Hospital of Los Angeles, Los Angeles, California
| | | | - John Simpson
- Evelina London Children's Hospital, London, United Kingdom
| | | | - Zhiyun Tian
- Children's Hospital of Philadelphia, Philadelphia, Pennsylvania
| |
Collapse
|
14
|
Should Prenatal Chromosomal Microarray Analysis Be Offered for Pulmonary Atresia? A Single-Center Retrospective Study in China. Genes (Basel) 2023; 14:genes14030722. [PMID: 36980994 PMCID: PMC10047995 DOI: 10.3390/genes14030722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/06/2023] [Accepted: 03/13/2023] [Indexed: 03/18/2023] Open
Abstract
(1) Objective: To evaluate the application of chromosomal microarray analysis (CMA) in fetuses with pulmonary atresia (PA) and to explore the risk factors for predicting chromosomal imbalances and adverse perinatal outcomes. (2) Methods: This study investigated 428 cases of PA singleton pregnancies that were tested using CMA and quantitative fluorescent polymerase chain reaction (QF-PCR) as first-line genetic testing. The PA cases were divided into two groups: an isolated group and a non-isolated group. (3) Results: CMA revealed clinically relevant copy number variations (CNVs) in 9/139 (6.47%) PA fetuses, i.e., pathogenic copy number variations (pCNVs) in 8/139 (5.76%) fetuses and likely pathogenic CNVs in 1/139 (0.72%) fetuses. Stratified analysis showed that the incidence of clinically significant variants was higher in non-isolated PA fetuses than in isolated PA fetuses (12.50%, 6/48 vs. 3.30%, 3/91, p = 0.036). Regression analysis showed that a combination of other structural abnormalities at diagnosis of PA represented the principal risk factor for chromosomal imbalances (OR = 2.672). A combination of other structural abnormalities and a high maternal age increased the risk of adverse pregnancy outcomes in PA cases, including intrauterine fetal death (IUFD), termination of pregnancy (TOP), and preterm delivery. (4) Conclusions: The value of CMA for locating imbalanced genetic variations in fetuses with PA was highlighted by this study, particularly when combined with additional structural abnormalities.
Collapse
|
15
|
Performance evaluation of computer-aided automated master frame selection techniques for fetal echocardiography. Med Biol Eng Comput 2023:10.1007/s11517-023-02814-1. [PMID: 36884143 DOI: 10.1007/s11517-023-02814-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 02/27/2023] [Indexed: 03/09/2023]
Abstract
PURPOSE Fetal echocardiography is widely used for the assessment of fetal heart development and detection of congenital heart disease (CHD). Preliminary examination of the fetal heart involves the four-chamber view which indicates the presence of all the four chambers and its structural symmetry. Examination of various cardiac parameters is generally done using the clinically selected diastole frame. This largely depends on the expertise of the sonographer and is prone to intra- and interobservational errors. To overcome this, automated frame selection technique is proposed for the recognition of fetal cardiac chamber from fetal echocardiography. METHODS Three techniques have been proposed in this research study to automate the process of determining the frame referred as "Master Frame" that can be used for the measurement of the cardiac parameters. The first method uses frame similarity measures (FSM) for the determination of the master frame from the given cine loop ultrasonic sequences. FSM makes use of similarity measures such as correlation, structural similarity index (SSIM), peak signal to noise ratio (PSNR), and mean square error (MSE) to identify the cardiac cycle, and all the frames in one cardiac cycle are superimposed to form the master frame. The final master frame is obtained by considering the average of the master frame obtained using each similarity measure. The second method uses averaging of ± 20% from the midframes (AMF). The third method uses averaging of all the frames (AAF) of the cine loop sequence. Both diastole and master frames have been annotated by the clinical experts, and their ground truths are compared for validation. No segmentation techniques have been used to avoid the variability of the performance of various segmentation techniques. All the proposed schemes were evaluated using six fidelity metrics such as Dice coefficient, Jaccard ratio, Hausdorff distance, structural similarity index, mean absolute error, and Pratt figure of merit. RESULTS The three proposed techniques were tested on the frames extracted from 95 ultrasound cine loop sequences between 19 and 32 weeks of gestation. The feasibility of the techniques was determined by the computation of fidelity metrics between the master frame derived and the diastole frame chosen by the clinical experts. The FSM-based identified master frame found to closely match with manually chosen diastole frame and also ensures statistically significant. The method also detects automatically the cardiac cycle. The resultant master frame obtained through AMF though found to be identical to that of the diastole frame, the size of the chambers found to be reduced that can lead to inaccurate chamber measurement. The master frame obtained through AAF was not found to be identical to that of clinical diastole frame. CONCLUSION It can be concluded that the frame similarity measure (FSM)-based master frame can be introduced in the clinical routine for segmentation followed by cardiac chamber measurements. Such automated master frame selection also overcomes the manual intervention of earlier reported techniques in the literature. The fidelity metrics assessment further confirms the suitability of proposed master frame for automated fetal chamber recognition.
Collapse
|
16
|
Ximenes RS, Bravo-Valenzuela NJ, Pares DBS, Araujo Júnior E. The use of cardiac ultrasound imaging in first-trimester prenatal diagnosis of congenital heart diseases. JOURNAL OF CLINICAL ULTRASOUND : JCU 2023; 51:225-239. [PMID: 36468264 DOI: 10.1002/jcu.23330] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 08/08/2022] [Indexed: 06/17/2023]
Abstract
This study aims to explore ultrasound (US) cardiac and echocardiographic features that may enable the early diagnosis of various major congenital heart diseases (CHDs). Focusing on providing useful US tools for this assessment, high resolution of US cardiac images of various CHDs, such as hypoplastic left heart syndrome, conotruncal anomalies, and univentricular heart, were evaluated. Results show that early US detection of most major CHDs is feasible during first-trimester ultrasonography cardiac evaluation. Concerns about safety issues, findings on early fetal cardiovascular hemodynamics, and cardiac lesions that can progress during the course of pregnancy were also discussed.
Collapse
Affiliation(s)
| | - Nathalie Jeanne Bravo-Valenzuela
- Discipline of Pediatrics, Department of Internal Medicine, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil
| | - David Baptista Silva Pares
- Department of Obstetrics, Paulista School of Medicine - Federal University of São Paulo (EPM-UNIFESP), São Paulo, SP, Brazil
| | - Edward Araujo Júnior
- Department of Obstetrics, Paulista School of Medicine - Federal University of São Paulo (EPM-UNIFESP), São Paulo, SP, Brazil
- Medical Course, Municipal University of São Caetano do Sul (USCS), São Paulo, SP, Brazil
| |
Collapse
|
17
|
Muñoz H, Enríquez G, Ortega X, Pinto M, Hosiasson S, Germain A, Díaz C, Cortés F. Diagnóstico de cardiopatías congénitas: ecografía de cribado, ecocardiografía fetal y medicina de precisión. REVISTA MÉDICA CLÍNICA LAS CONDES 2023. [DOI: 10.1016/j.rmclc.2023.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023] Open
|
18
|
Lin DM, Zhu YX, Tan Y, Huang YJ, Yuan K, Liu WF, Xu ZF. Feasibility of Transabdominal Real-time CDFI and HDFI Techniques for Fetal Pulmonary Vein Display in the First Trimester. Curr Med Sci 2022; 42:635-641. [PMID: 35511413 DOI: 10.1007/s11596-022-2569-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Accepted: 06/07/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE This study aimed to assess the feasibility and usefulness of transabdominal color Doppler flow imaging (CDFI) technology and the high-definition flow imaging (HDFI) technique in detecting fetal pulmonary veins (PVs) in the first trimester (11-13+6 weeks). METHODS From December 2018 to October 2019, 328 pregnant women with 328 normal singleton fetuses (crown-rump length: 45-84 mm) who had undergone CDFI and HDFI scans for fetal heart and vessel examination were enrolled in this study. The cases were divided into three groups according to the gestational age: group A, 11+0 -11+6 weeks; group B, 12+0 -12+6 weeks; and group C, 13+0 -13+6 weeks. Baseline sonograms and CDFI and HDFI images were analyzed by two senior radiologists independently and blindly. The abilities of CDFI and HDFI to display PVs were compared. RESULTS Successful PV display rates via CDFI and HDFI were 2.3% and 68.2% (P<0.01), 22.4% and 82.4% (P<0.01), 41.5% and 91.2% (P<0.01) for group A, group B, and group C, respectively. The total successful display rates for the two methods were 28.9% (CDFI) and 84.8% (HDFI) (P<0.01). CONCLUSIONS The HDFI technique is more valuable than CDFI for detecting PVs in early pregnancy (11-13+6 weeks). HDFI can detect at least one PV in all cases and may be used to detect pulmonary venous anomalies early.
Collapse
Affiliation(s)
- Dong-Mei Lin
- Department of Medical Ultrasonics, The Seventh Affiliated Hospital of Sun Yat-sen University, Shenzhen, 518107, China.,Department of Medical Ultrasonics, South China Hospital of Shenzhen University, Shenzhen, 518000, China
| | - Yun-Xiao Zhu
- Department of Medical Ultrasonics, The Seventh Affiliated Hospital of Sun Yat-sen University, Shenzhen, 518107, China
| | - Ying Tan
- Department of Medical Ultrasonics, The Seventh Affiliated Hospital of Sun Yat-sen University, Shenzhen, 518107, China
| | - Yu-Jun Huang
- Department of Medical Ultrasonics, The Seventh Affiliated Hospital of Sun Yat-sen University, Shenzhen, 518107, China
| | - Kun Yuan
- Department of Medical Ultrasonics, The Seventh Affiliated Hospital of Sun Yat-sen University, Shenzhen, 518107, China
| | - Wen-Fen Liu
- Department of Medical Ultrasonics, The Seventh Affiliated Hospital of Sun Yat-sen University, Shenzhen, 518107, China
| | - Zuo-Feng Xu
- Department of Medical Ultrasonics, The Seventh Affiliated Hospital of Sun Yat-sen University, Shenzhen, 518107, China.
| |
Collapse
|
19
|
Sandrini C, Lombardi C, Zambelli V, Zanarotti R, Raffaelli R, Franchi M, Papadopoulos N, Di Pace C, Hoxha S, Murari A, Chamitava L, Zanolin M, Faggian G, Ribichini F, Rossetti L, Luciani G. What can we learn from systematic segmental analysis of fetal heart by postmortem micro-CT: Is it time to change approach? INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE 2022; 7:100308. [PMID: 39712275 PMCID: PMC11657735 DOI: 10.1016/j.ijcchd.2021.100308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 12/03/2021] [Accepted: 12/14/2021] [Indexed: 10/19/2022] Open
Abstract
Background Postmortem analysis of fetal heart is crucial but challenging. Alternative techniques to autopsy have been studied. We investigate micro-CT diagnostic accuracy in the analysis of fetal heart coming from early and late termination of pregnancy. Methods Micro-CT and autopsy analyzed human fetal heart using twenty-six indices of cardiac anatomy derived from segmental approach. Sub-analysis of smaller specimens was performed. Primary outcome is the agreement between techniques. Secondary outcomes are sensitivity, specificity, positive and negative predictive value. Indices are defined "visible" or "non-visible" (primary end point) and "normal", "abnormal" or "non-diagnostic" (secondary end point). Results Fifty-five cases were included. Agreement was 74.5% and 65.2% for primary end point and 93.3% and 91.8% for secondary end point in general population and in the group of smaller specimens, respectively. Sensitivity, specificity, positive and negative predictive value were 92.8%, 51.8%, 67.1%, 87.2% in the general population and 92.8%, 47.8%, 54.3%, 90.9% in the subgroup of smaller specimens for primary end point. They were 97.3%, 68.3%, 95.1%, 80.0% in the general population and 95.7%, 75.6%, 94.2%, 81.0% in the subgroup of smaller specimens for secondary end point. 86.1% and 91.5% of indices defined as "non-diagnostic" at autopsy would be visible by micro-CT in the two studied populations. Conclusion Micro-CT represents a valid alternative to autopsy for postmortem evaluation of human fetal heart. We proposed to use micro-CT for initial analysis of fetal heart and to perform autopsy only in unsolved cases or if histological analysis is needed.
Collapse
Affiliation(s)
- C. Sandrini
- Division of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | | | - V. Zambelli
- School of Medicine and Surgery, University of Milano Bicocca, Monza, Italy
| | - R. Zanarotti
- Division of Obstetrics and Gynecology, ULSS 9 Scaligera, Verona, Italy
| | - R. Raffaelli
- Division of Obstetrics and Gynecology A, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - M.P. Franchi
- Division of Obstetrics and Gynecology A, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - N. Papadopoulos
- Division of Obstetrics and Gynecology B, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - C. Di Pace
- Department of Pathology, Department of Diagnostics and Public Health, University of Verona, Verona, Italy
| | - S. Hoxha
- Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - A. Murari
- Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - L. Chamitava
- Unit of Epidemiology and Medical Statistics, Department of Diagnostics and Public Health, University of Verona, Verona, Italy
| | - M.E. Zanolin
- Unit of Epidemiology and Medical Statistics, Department of Diagnostics and Public Health, University of Verona, Verona, Italy
| | - G. Faggian
- Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - F.L. Ribichini
- Division of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | - L. Rossetti
- Division of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | - G.B. Luciani
- Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| |
Collapse
|
20
|
Master Frame Extraction of Fetal Cardiac Images Using B Mode Ultrasound Images. JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING 2022. [DOI: 10.4028/www.scientific.net/jbbbe.54.51] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Fetal Echocardiography is used for monitoring the fetal heart and for detection of Congenital Heart Disease (CHD). It is well known that fetal cardiac four chamber view has been widely used for preliminary examination for the detection of CHD. The end diastole frame is generally used for the analysis of the fetal cardiac chambers which is manually picked by the clinician during examination/screening. This method is subjected to intra and inter observer errors and also time consuming. The proposed study aims to automate this process by determining the frame, referred to as the Master frame from the cine loop sequences that can be used for the analysis of the fetal heart chambers instead of the clinically chosen diastole frame. The proposed framework determines the correlation between the reference (first) frame with the successive frames to identify one cardiac cycle. Then the Master frame is formed by superimposing all the frames belonging to one cardiac cycle. The master frame is then compared with the clinically chosen diastole frame in terms of fidelity metrics such as Dice coefficient, Hausdorff distance, mean square error and structural similarity index. The average value of the fidelity metrics considering the dataset used for this study 0.73 for Dice, 13.94 for Hausdorff distance, 0.99 for Structural Similarity Index and 0.035 for mean square error confirms the suitability of the proposed master frame extraction thereby avoiding manual intervention by the clinician. .
Collapse
|
21
|
Cordisco Md A, Lozza V, Filice ME, Chiappa E. First trimester prenatal diagnosis of a severe tricuspid valve regurgitation and pulmonary valve atresia. Echocardiography 2021; 38:2119-2121. [PMID: 34747067 DOI: 10.1111/echo.15242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Accepted: 10/21/2021] [Indexed: 11/28/2022] Open
Abstract
Early diagnosis of congenital heart defect (CHD) increased in the last two decades, following technological evolution. A recent meta-analysis (Yu, 2020), on diagnostic accuracy in ultrasound detection of major CHD in the first trimester of pregnancy, reported an overall sensitivity of 75%. Ultrasound imaging of this case refers to a tricuspid valve dysplasia with right atriomegaly and pulmonary valve atresia diagnosed in a 13-week gestational-age fetus with low risk for chromosomal abnormalities. To our knowledge, this is the first case describing such features in the first trimester. We believe the precocity and severity of onset make this a case of diagnostic interest.
Collapse
Affiliation(s)
- Adalgisa Cordisco Md
- Division of Prenatal Diagnosis, Materno Infantile Department, Azienda USL Toscana Centro, San Giovanni di Dio Hospital, Firenze, Italy
| | - Virginia Lozza
- Division of Prenatal Diagnosis, Materno Infantile Department, Azienda USL Toscana Centro, San Giovanni di Dio Hospital, Firenze, Italy
| | - Maria Elena Filice
- Division of Anatomia Patologica 2, Department of Medicina di Laboratorio, Azienda Ospedaliero-Universitaria Pisana, Pisa, Italy
| | - Enrico Chiappa
- Division of Pediatric Cardiology, National Research Center - Tuscany Region Foundation "G. Monasterio", Ospedale del Cuore, Massa, Italy
| |
Collapse
|
22
|
Ye B, Wu Y, Chen J, Yang Y, Niu J, Wang H, Wang Y, Cheng W. The diagnostic value of the early extended fetal heart examination at 13 to 14 weeks gestational age in a high-risk population. Transl Pediatr 2021; 10:2907-2920. [PMID: 34976757 PMCID: PMC8649590 DOI: 10.21037/tp-21-255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Accepted: 09/22/2021] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Congenital heart disease (CHD) is the most common congenital malformation that affects high-risk populations. A more definite heart diagnosis in the first trimester should be provided to guide clinical treatment. The study aim was to evaluate the diagnostic precision of the early extended fetal heart examination (EFHE) that includes abdominal situs view, four-chamber view (4CV), left ventricular outflow tract view (LVOT), right ventricular outflow tract view (RVOT), 3-vessel and tracheal view (3VT), ductal arch view, and the aortic arch view in the detection of CHD at the gestational age (GA) 13 to 14 weeks in a population with high risks. METHODS This study was a diagnostic test study. EFHE was performed by transabdominal sonography in women at GA 13 to 14 weeks with singleton pregnancies who were at high risk for CHD. The risk of CHD was determined by family history of CHD, rubella infection, metabolic disorders, exposure to teratogens, conception by in-vitro fertilization (IVF), increased nuchal translucency (NT) thickness, abnormal obstetric ultrasound, etc. The operator had more than 5 years of experience in first-trimester scans and fetal echocardiography. Early scans were compared with a fetal echocardiography in the second trimester (16-24 weeks). RESULTS EFHE was performed, and the pregnancy outcomes were obtained in 234 single pregnancies with a high risk of CHD. The average crown-rump length (CRL) was (76.17±7.09) mm. CHD was diagnosed in 43 cases by EFHE; 10 of these cases were misdiagnosed, and 2 cases were missed. Four cases were inconsistent in the main diagnosis of CHD. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and kappa coefficient (Ko) value of EFHE in diagnosing CHD by type and severity was 84.6% [95% confidence interval (CI), 69.5-94.1%], 96.9% (95% CI, 93.4-98.9%), 84.6% (95% CI, 69.5-94.1%), 96.9% (95% CI, 93.4-98.9%), and 0.82 (P<0.001), respectively. CONCLUSIONS EFHE can work as a diagnose examination for most major CHD cases at GA 13 to 14 weeks by an experienced operator; Therefore, this diagnostic system for fetal CHD may be applied in the first trimester. The study has been registered in the Chinese Clinical Trial Registry (www.chictr.org.cn). The registration number is ChiCTR2000038451.
Collapse
Affiliation(s)
- Baoying Ye
- Department of Ultrasonography, the International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.,Shanghai Key Laboratory of Embryo Original Diseases, Shanghai, China.,Shanghai Municipal Key Clinical Specialty, Shanghai, China
| | - Yi Wu
- Department of Prenatal Diagnostic Center, the International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Jiong Chen
- Department of Ultrasonography, the International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yu Yang
- Department of Ultrasonography, the International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Jianmei Niu
- Department of Ultrasonography, the International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Hui Wang
- Department of Ultrasonography, the International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yanlin Wang
- Department of Prenatal Diagnostic Center, the International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Weiwei Cheng
- Shanghai Key Laboratory of Embryo Original Diseases, Shanghai, China.,Shanghai Municipal Key Clinical Specialty, Shanghai, China.,Department of Obstetrics and Gynecology, the International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
23
|
Sandrini C, Boito S, Lombardi CM, Lombardi S. Postmortem Micro-CT of Human Fetal Heart-A Systematic Literature Review. J Clin Med 2021; 10:jcm10204726. [PMID: 34682849 PMCID: PMC8539069 DOI: 10.3390/jcm10204726] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 10/06/2021] [Accepted: 10/09/2021] [Indexed: 12/20/2022] Open
Abstract
Micro-computed tomography (CT) is a non-invasive alternative to conventional macroscopic dissection for the evaluation of human fetal cardiac anatomy. This paper aims to systematically review the literature regarding the use of micro-CT to examine human fetal hearts, to illustrate its educational and research implications and to explain its possible directions for the future. A systematic literature review was conducted following the PRISMA statement to identify publications concerning micro-CT applications for the isolated human fetal heart. The search strategy identified nine eligible studies. Micro-CT is technically feasible for postmortem examination of the human fetal heart coming from early and late termination of pregnancy. It reaches high diagnostic accuracy, and it seems to perform better than autopsy in small samples or in the case of early termination of pregnancy. Applications derived from micro-CT allow multiple off-time evaluations and interdisciplinary comparisons for educational purposes and research perspectives in biological and bioengineering domains.
Collapse
Affiliation(s)
- Camilla Sandrini
- Division of Cardiology, Department of Medicine, University of Verona, 37126 Verona, Italy
- Correspondence:
| | - Simona Boito
- Fetal Medicine and Surgery Service, Fondazione IRCCS Ca’ Granda, Ospedale Maggiore Policlinico, 20122 Milan, Italy;
| | | | - Sophie Lombardi
- Department of Diagnostic and Interventional Radiology, Fondazione IRCCS Policlinico San Matteo, 27100 Pavia, Italy;
| |
Collapse
|
24
|
Perez-Miguelsanz J, Jiménez-Ortega V, Cano-Barquilla P, Garaulet M, Esquifino AI, Varela-Moreiras G, Fernández-Mateos P. Early Appearance of Epicardial Adipose Tissue through Human Development. Nutrients 2021; 13:nu13092906. [PMID: 34578784 PMCID: PMC8469969 DOI: 10.3390/nu13092906] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 08/13/2021] [Accepted: 08/17/2021] [Indexed: 12/21/2022] Open
Abstract
Background: Epicardial adipose tissue (EAT) is a visceral fat depot with unique anatomic, biomolecular and genetic features. Due to its proximity to the coronary arteries and myocardium, dysfunctional EAT may contribute to the development and progression of cardiovascular and metabolic-related adiposity-based chronic diseases. The aim of this work was to describe, by morphological techniques, the early origin of EAT. Methods: EAT adipogenesis was studied in 41 embryos from 32 gestational days (GD) to 8 gestational weeks (GW) and in 23 fetuses until full term (from 9 to 36 GW). Results: This process comprises five stages. Stage 1 appears as mesenchyme at 33-35 GD. Stage 2 is characterized by angiogenesis at 42-45 GD. Stage 3 covers up to 34 GW with the appearance of small fibers in the extracellular matrix. Stage 4 is visible around the coronary arteries, as multilocular adipocytes in primitive fat lobules, and Stage 5 is present with unilocular adipocytes in the definitive fat lobules. EAT precursor tissue appears as early as the end of the first gestational month in the atrioventricular grooves. Unilocular adipocytes appear at the eighth gestational month. Conclusions: Due to its early origin, plasticity and clinical implications, factors such as maternal health and nutrition might influence EAT early development in consequence.
Collapse
Affiliation(s)
- Juliana Perez-Miguelsanz
- Departamento de Anatomía y Embriología, Facultad de Medicina, Universidad Complutense de Madrid, 28040 Madrid, Spain;
- Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28003 Madrid, Spain; (V.J.-O.); (P.C.-B.); (A.I.E.)
| | - Vanesa Jiménez-Ortega
- Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28003 Madrid, Spain; (V.J.-O.); (P.C.-B.); (A.I.E.)
- Departamento de Bioquímica y Biología Molecular, Facultad de Medicina, Universidad Complutense de Madrid, 28040 Madrid, Spain
| | - Pilar Cano-Barquilla
- Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28003 Madrid, Spain; (V.J.-O.); (P.C.-B.); (A.I.E.)
- Departamento de Bioquímica y Biología Molecular, Facultad de Medicina, Universidad Complutense de Madrid, 28040 Madrid, Spain
| | - Marta Garaulet
- Departamento de Fisiología, Universidad de Murcia, IMIB-Arrixaca, 30120 Murcia, Spain;
| | - Ana I. Esquifino
- Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28003 Madrid, Spain; (V.J.-O.); (P.C.-B.); (A.I.E.)
- Departamento de Bioquímica y Biología Molecular, Facultad de Medicina, Universidad Complutense de Madrid, 28040 Madrid, Spain
| | - Gregorio Varela-Moreiras
- Departamento de Ciencias Farmacéuticas y de la Salud, Facultad de Farmacia, Universidad CEU San Pablo, Boadilla del Monte, 28668 Madrid, Spain;
| | - Pilar Fernández-Mateos
- Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28003 Madrid, Spain; (V.J.-O.); (P.C.-B.); (A.I.E.)
- Departamento de Biología Celular, Facultad de Medicina, Universidad Complutense, 28040 Madrid, Spain
- Correspondence: ; Tel.: +34-913-947-256
| |
Collapse
|
25
|
Kesrouani A, Abdallah W, Kharrat R, Choueiry E, Daou L, Nasr B. Normal values of cardiac axis (CA) measurements in healthy fetuses during the first trimester screening ultrasound. J Perinat Med 2021; 49:496-499. [PMID: 33470962 DOI: 10.1515/jpm-2020-0457] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2020] [Accepted: 12/02/2020] [Indexed: 11/15/2022]
Abstract
OBJECTIVES To report the normal fetal cardiac axis (CA) values at the time of the first trimester screening ultrasound. METHODS Standardized images and measurement of the CA were obtained from 100 healthy fetuses between 11+0 and 13+6 weeks of gestation along with the nucal thichkness (NT), Crown-rump length (CRL) and other measurements. We excluded cases with abnormal NT, later diagnosis of abnormalities, and suspected fetal cardiopathy during the pregnancy follow-up. Data analysis was performed after all the patients delivered and cardiopathy was excluded. RESULTS CA was measurable in all the cases. Higher CRL was associated with a decrease in the CA. The mean ± SD embryonic/fetal CA was 48±5,2°, ranging from 39 to 60°, The 2.5 percentile was defined at 40° and the 97.5 percentile at 59°. The Pearson test resulted in a significant correlation between CA and CRL with a coefficient R of 70% and p-value <0.01. CONCLUSIONS CA tends to decrease at the 11 to 13+6 gestational ages. We defined 2.5 and 97.5% curves for the normal values of CA in our Middle Eastern population. A larger study will be required to differentiate normal and abnormal values for the early detection of heart abnormalities.
Collapse
Affiliation(s)
- Assaad Kesrouani
- Obstetrics and Gynecology Department, St Joseph University, Beirut, Lebanon.,Bellevue Medical Center Hospital, Hotel-Dieu de France Hospital, Beirut, Lebanon
| | - Wael Abdallah
- Obstetrics and Gynecology Department, St Joseph University, Beirut, Lebanon.,Bellevue Medical Center Hospital, Hotel-Dieu de France Hospital, Beirut, Lebanon
| | - Roland Kharrat
- Faculty of Medicine, St Joseph University, Beirut, Lebanon.,Hotel-Dieu de France Hospital, Beirut, Lebanon
| | - Elie Choueiry
- Hotel-Dieu de France Hospital, Beirut, Lebanon.,Pediatrics Department, St Joseph University, Beirut, Lebanon
| | - Linda Daou
- Hotel-Dieu de France Hospital, Beirut, Lebanon.,Pediatrics Department, St Joseph University, Beirut, Lebanon
| | - Bernard Nasr
- Bellevue Medical Center Hospital, Beirut, Lebanon
| |
Collapse
|
26
|
Smith SF, Miloro P, Axell R, ter Haar G, Lees C. In vitro characterisation of ultrasound-induced heating effects in the mother and fetus: A clinical perspective. ULTRASOUND (LEEDS, ENGLAND) 2021; 29:73-82. [PMID: 33995553 PMCID: PMC8083135 DOI: 10.1177/1742271x20953197] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Accepted: 08/04/2020] [Indexed: 12/11/2022]
Abstract
INTRODUCTION The quantification of heating effects during exposure to ultrasound is usually based on laboratory experiments in water and is assessed using extrapolated parameters such as the thermal index. In our study, we have measured the temperature increase directly in a simulator of the maternal-fetal environment, the 'ISUOG Phantom', using clinically relevant ultrasound scanners, transducers and exposure conditions. METHODS The study was carried out using an instrumented phantom designed to represent the pregnant maternal abdomen and which enabled temperature recordings at positions in tissue mimics which represented the skin surface, sub-surface, amniotic fluid and fetal bone interface. We tested four different transducers on a commercial diagnostic scanner. The effects of scan duration, presence of a circulating fluid, pre-set and power were recorded. RESULTS The highest temperature increase was always at the transducer-skin interface, where temperature increases between 1.4°C and 9.5°C were observed; lower temperature rises, between 0.1°C and 1.0°C, were observed deeper in tissue and at the bone interface. Doppler modes generated the highest temperature increases. Most of the heating occurred in the first 3 minutes of exposure, with the presence of a circulating fluid having a limited effect. The power setting affected the maximum temperature increase proportionally, with peak temperature increasing from 4.3°C to 6.7°C when power was increased from 63% to 100%. CONCLUSIONS Although this phantom provides a crude mimic of the in vivo conditions, the overall results showed good repeatability and agreement with previously published experiments. All studies showed that the temperature rises observed fell within the recommendations of international regulatory bodies. However, it is important that the operator should be aware of factors affecting the temperature increase.
Collapse
Affiliation(s)
| | - Piero Miloro
- Ultrasound and Underwater Acoustics, National Physical Laboratory, UK
| | - Richard Axell
- Medical Physics and Bioengineering, University College Hospital NHS Foundation Trust, UK
- Queen Square Institute of Neurology, University College London, UK
| | - Gail ter Haar
- Therapeutic Ultrasound, Division of Radiotherapy and Imaging, Joint Department of Physics, Institute of Cancer Research, Royal Marsden NHS Foundation Trust, UK
| | - Christoph Lees
- Centre for Fetal Care, Queen Charlotte’s & Chelsea Hospital, Imperial College Healthcare NHS Trust, UK
| |
Collapse
|
27
|
AIUM Practice Parameter for the Performance of Detailed Diagnostic Obstetric Ultrasound Examinations Between 12 Weeks 0 Days and 13 Weeks 6 Days. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021; 40:E1-E16. [PMID: 32852128 DOI: 10.1002/jum.15477] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Accepted: 08/04/2020] [Indexed: 06/11/2023]
|
28
|
Wen C, Huang L, Jiang H. Diagnosis of Interventional Transvaginal Maternal Diseases Based on Color Doppler Ultrasound. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:5517785. [PMID: 33868617 PMCID: PMC8032514 DOI: 10.1155/2021/5517785] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 03/15/2021] [Accepted: 03/22/2021] [Indexed: 11/18/2022]
Abstract
In recent years, with the development of color Doppler ultrasound technology in obstetrics, this noninvasive, direct, convenient, and sensitive inspection method has become one of the best methods to observe the fetal circulation in the uterus. This paper discusses the clinical value of using transvaginal color Doppler ultrasound in the differential diagnosis of ovarian corpus luteum disease and ectopic pregnancy disease. This paper selects 100 cases of ectopic pregnancy and 100 cases of pregnant corpus luteum as the experimental research objects. Clinical analysis of transvaginal color Doppler ultrasonography was performed on all patients. In the process of measuring the patient's ectopic pregnancy, the size of the patient's adnexal mass is mainly measured, and the blood flow spectrum is measured. The clinical choice of transvaginal color Doppler ultrasound method to distinguish ectopic pregnancy disease and corpus luteum pregnancy disease can play a significant value. It can be effectively diagnosed according to the type of disease, then effective methods can be studied for clinical treatment, the quality of life of patients with the two diseases can be significantly improved, and the clinical application value of color Doppler ultrasound can be improved.
Collapse
Affiliation(s)
- Canliang Wen
- Department of Obstetrics and Gynecology, Guangzhou Women and Children's Medical Center, Guangzhou, Guangdong 510623, China
| | - Lan Huang
- Department of Ultrasound, Guangzhou Women and Children's Medical Center, Guangzhou, Guangdong 510623, China
| | - Hongye Jiang
- Department of Obstetrics and Gynecology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510080, China
| |
Collapse
|
29
|
Hildebrand E. First-Trimester Diagnosis of Hypoplastic Left Heart Syndrome: A Case Report. JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY 2021. [DOI: 10.1177/8756479320975692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Hypoplastic left heart syndrome (HLHS) comprises a spectrum of left-sided heart anomalies resulting from left outflow or inflow obstruction. Obstruction most often occurs at the levels of the aortic valve and/or mitral valve due to stenosis or atresia. HLHS is a lethal cardiac anomaly if not treated within the first week of life. Knowledge of sonographic features could aid in early detection, which results in better planning and management of pregnancy. This report presents a case in which HLHS was discovered during a routine dating and viability sonogram, performed at 12 weeks’ gestation.
Collapse
|
30
|
García Delgado R, García Rodríguez R, Ortega Cárdenes I, González Martín JM, De Luis Alvarado M, Segura González J, Medina Castellano M, García Hernández JA. Feasibility and Accuracy of Early Fetal Echocardiography Performed at 13 +0-13 +6 Weeks in a Population with Low and High Body Mass Index: a Prospective Study. Reprod Sci 2021; 28:2270-2277. [PMID: 33559059 DOI: 10.1007/s43032-021-00477-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2020] [Accepted: 01/24/2021] [Indexed: 10/22/2022]
Abstract
PURPOSE The earlier the detection and diagnosis of congenital heart diseases (CHD), the greater the clinical benefit; however, early fetal cardiac examination can be a challenge. The aim of our study is to demonstrate that the fetal cardiac examination at 13+0-13+6 weeks can be as adequately assessed as the examination performed at 16 weeks in patients with low and high body mass index (BMI). METHODS The study was a prospective observational cohort study. One hundred pregnant women at low risk of congenital heart anomalies were divided into two groups: 49 women with low BMI (<25) and 51 women with high BMI (≥ 25). A complete fetal cardiac scan was performed on each patient at 13+0-13+6 weeks, via the transvaginal and transabdominal approaches, and at 16 weeks by the transabdominal approach. RESULTS The examination at 13+0-13+6 weeks was adequately assessed in at least one of the two routes in 97 patients, as opposed to 87 patients at 16 weeks. A significantly higher adequate assessment rate was obtained at 13+0-13+6 weeks than at 16 weeks (p=0.017). The transvaginal approach showed the best resolution of the three examinations in 42% of women with BMI ≥35. No CHD were overlooked. CONCLUSIONS Early fetal echocardiography is feasible and accurate at 13+0-13+6 weeks. Within patients with high BMI, early fetal echocardiography may be performed two weeks in advance, since it allows visualization of the fetal heart through the transvaginal route with a higher resolution in a large number of women, which is not feasible at 16 weeks.
Collapse
Affiliation(s)
- Raquel García Delgado
- Department of Obstetrics and Gynecology, Hospital Universitario Materno Infantil de Canarias, Las Palmas de Gran Canaria, Spain.
| | - Raquel García Rodríguez
- Department of Obstetrics and Gynecology, Hospital Universitario Materno Infantil de Canarias, Las Palmas de Gran Canaria, Spain
| | - Ismael Ortega Cárdenes
- Department of Obstetrics and Gynecology, Hospital Universitario Materno Infantil de Canarias, Las Palmas de Gran Canaria, Spain
| | - Jesús M González Martín
- Bioestatistics Division, Research Unit, Hospital Universitario Dr. Negrín, Las Palmas de Gran Canaria, Spain
| | - María De Luis Alvarado
- Department of Obstetrics and Gynecology, Hospital Universitario Materno Infantil de Canarias, Las Palmas de Gran Canaria, Spain
| | - Javier Segura González
- Department of Obstetrics and Gynecology, Hospital Universitario Materno Infantil de Canarias, Las Palmas de Gran Canaria, Spain
| | - Margarita Medina Castellano
- Department of Obstetrics and Gynecology, Hospital Universitario Materno Infantil de Canarias, Las Palmas de Gran Canaria, Spain
| | - Jose A García Hernández
- Department of Obstetrics and Gynecology, Hospital Universitario Materno Infantil de Canarias, Las Palmas de Gran Canaria, Spain
| |
Collapse
|
31
|
Prenatal Detection of Congenital Heart Disease: the Past, Present, and Future. CURRENT TREATMENT OPTIONS IN CARDIOVASCULAR MEDICINE 2021. [DOI: 10.1007/s11936-020-00886-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
32
|
Herghelegiu CG, Duta SF, Neacsu A, Suciu N, Veduta A. Operator experience impact on the evaluation of still images of a first trimester cardiac assessment protocol. J Matern Fetal Neonatal Med 2020; 35:1957-1961. [PMID: 32498650 DOI: 10.1080/14767058.2020.1774873] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Objective: Congenital heart disease (CHD) is the most common birth defect and represents the leading cause for mortality and morbidity in infants and young adults. Early fetal echocardiography is usually considered a highly specialized scan. The goal of this study is to evaluate the impact of operator's experience in assessing still images of the 4-chamber view and 3-vessels view and to evaluate the feasibility and the performance of a first trimester screening protocol for CHD.Methods: An online questionnaire consisting of still images of the 4-camber view and 3-vessel view from 50 normal and abnormal cases was reviewed by an expert group made of seven obstetricians specialized in fetal medicine and a nonexpert group made of 13 obstetricians that are certified in ultrasound. After individually visualizing each image set made of the 4-chamber view and 3-vessel view, they had to conclude if the case was normal or abnormal and what images were abnormal.Results: A total of 50 image sets of both normal and abnormal fetal hearts were examined by the 20 reviewers, resulting in 1000 evaluations. The expert group achieved a detection rate of 97.1% with a false positive rate of 5.7%. The nonexpert group achieved also a good detection rate of 91.3% but with a much higher false positive rate of 33.9%. The most frequently missed CHD involved the great arteries and had a normal 4-chamber view. In the majority of false positive cases the 3-vessel view was incorrectly interpreted as abnormal.Conclusions: A screening protocol for CHD, based on the 4-chamber view and 3-vessel view alone can offer a good detection rate for CHD with a small false positive rate, but only if it is implemented by highly specialized sonographers.
Collapse
Affiliation(s)
- Catalin Gabriel Herghelegiu
- "Carol Davila" University of Medicine and Pharmacy, Bucharest, Romania.,INSMC "Alessandrescu Rusescu", Bucharest, Romania
| | | | - Adrian Neacsu
- "Carol Davila" University of Medicine and Pharmacy, Bucharest, Romania.,Department of Obstetrics and Gynecology, "St. John" Emergency Clinical Hospital, Bucharest, Romania
| | - Nicolae Suciu
- "Carol Davila" University of Medicine and Pharmacy, Bucharest, Romania.,INSMC "Alessandrescu Rusescu", Bucharest, Romania
| | - Alina Veduta
- "Filantropia" Clinical Hospital, Bucharest, Romania
| |
Collapse
|
33
|
|
34
|
Kamel H, Yehia A. First trimester fetal echocardiography limitations and its expected clinical values. Egypt Heart J 2020; 72:16. [PMID: 32266496 PMCID: PMC7138880 DOI: 10.1186/s43044-020-00049-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2019] [Accepted: 03/20/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Fetal cardiac activity could be observed between 6th and 7th gestational weeks, early performance of fetal echocardiography could be implemented to screen for fetal heart disease. The effectiveness of early first trimester fetal echocardiography has not been adequately investigated, especially with modern sonographic technological advances. The purpose of the study is to evaluate the capability to visualize fetal cardiac structures within the first trimester as early as 10th gestational weeks and to elucidate the value of using color Doppler in visualization of cardiac structures within early gestation. A prospective clinical trial conducted on 150 study subjects, 44 of them were twin gestations. Cases were fully assessed by fetal echocardiographic examination from 10th gestational week to 13 gestational weeks in a sequential manner weekly. The research study was conducted at cardiology department fetal unit in one of the tertiary hospitals. RESULTS Four chamber view was mostly visualized from 12 gestational weeks, whereas cardiac axis was fully visualized in all cases from 12 gestational weeks; on the other hand, IVC assessment by 2D was satisfactorily visualized in 78.26% of cases and by color Doppler in 82.61% of cases at 13 gestational weeks, pulmonary veins were visualized in 21.74% of cases by 2D and 43.5% of cases by color Doppler at 13 gestational weeks, and interestingly, ventricular inflows were satisfactorily visualized in almost all cases from 10th gestational weeks. CONCLUSIONS First trimester fetal echo is an outstanding enhancement in management pathways of cases susceptible to have fetal cardiac abnormalities permitting early detection of structural cardiac anomalies triggering a cascade of scanning for extra cardiac anomalies to aid in evaluation and assessment of the best management course for those affected cases.
Collapse
Affiliation(s)
- Heba Kamel
- Congenital and Structural Heart Disease Unit, Department of Cardiology, Faculty of Medicine, Ain Shams University Hospital, Abbassya, Cairo, Egypt.
| | - Amr Yehia
- Department of Obstetrics and Gynecology, Faculty of Medicine, Ain Shams University, Cairo, Egypt
| |
Collapse
|
35
|
Sokołowski Ł, Fendler W, Tobota Z, Kordjalik P, Krekora M, Słodki M, Respondek-Liberska M. Detection screening and seasonality evaluation of hypoplastic left heart syndrome in the polish national registry for fetal cardiac anomalies from the years 2004 to 2016. Prenat Diagn 2020; 40:698-704. [PMID: 32134135 DOI: 10.1002/pd.5677] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 02/16/2020] [Accepted: 02/18/2020] [Indexed: 12/16/2022]
Abstract
OBJECTIVES To evaluate the incidence of hypoplastic left heart syndrome (HLHS) and the efficiency of the screening program using data from the Polish National Registry for Fetal Cardiac Anomalies. To investigate whether HLHS incident rates in Poland are seasonally variable. METHODS Data on 791 cases of HLHS from the Registry collected between 2004 and 2016 was analyzed. RESULTS The median gestational age for the 734 cases of HLHS detected was 23 weeks. Comparing the age at time of HLHS detection between 2004 and 2016, a decrease from 26 to 20.8 weeks was observed. We noted a rapid increase in HLHS incidence during the initial years of the Registry data, the annual percentage change during that period was 22.0% and this trend lasted until 2010. In the following years, the Registry became representative of the general population which has an estimated incidence of HLHS of 20.93 cases per 100 000 live births. We observed no clear seasonal patterns of HLHS incidence in our population. CONCLUSION The Registry reached a plateau state in terms of diagnosing new cases of HLHS. No evidence of seasonality has been noted. The average gestational age of patients identified as having HLHS decreased significantly during the study period.
Collapse
Affiliation(s)
- Łukasz Sokołowski
- Department of Obstetrics & Gynaecology, Polish Mother's Memorial Hospital, Lodz, Poland.,Department of Prenatal Cardiology, Polish Mother's Memorial Hospital, Lodz, Poland
| | - Wojciech Fendler
- Department of Radiation Oncology, Dana-Farber Cancer Institute, Boston, Massachusetts.,Department of Biostatistics and Translational Medicine, Medical University of Lodz, Lodz, Poland
| | | | - Paulina Kordjalik
- Department of Prenatal Cardiology, Polish Mother's Memorial Hospital, Lodz, Poland
| | - Michał Krekora
- Department of Obstetrics & Gynaecology, Polish Mother's Memorial Hospital, Lodz, Poland
| | - Maciej Słodki
- Department of Prenatal Cardiology, Polish Mother's Memorial Hospital, Lodz, Poland.,Faculty of Health Sciences, The State University of Applied Sciences in Plock, Plock, Poland
| | - Maria Respondek-Liberska
- Department for Diagnoses and Prevention Fetal Malformations, Medical University of Lodz, Lodz, Poland
| |
Collapse
|
36
|
Hildebrand E. Sonographic Evaluation of Fetal Cardiac Anatomy in the Late First Trimester. JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY 2020. [DOI: 10.1177/8756479319891127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Objective: Congenital heart defects (CHDs) are the most common cause of infant death in the United States. Severe, complex cardiac anomalies make up approximately half of the cases and carry significant morbidity and mortality. The purpose of this literature review was to define a CHD screening protocol to be used in the first trimester. Methods: Literature was pulled that discussed the impact of color Doppler and spatiotemportal image correlation on image quality, explored the benefits and limitations of early screening, and analyzed the risk of bioeffects to the developing fetus. Results: A simplified cardiac screening protocol has been shown to be a feasible addition to the first trimester nuchal translucency scan. Conclusion: Color Doppler and three-dimensional sonography can be utilized during the first trimester to evaluate the fetal heart for major anomalies between 11 weeks and 13 weeks 6 days. Recommendations for future research and guidance from accrediting bodies are provided.
Collapse
|
37
|
Haxel C, Glickstein J, Parravicini E. Neonatal Palliative Care for Complicated Cardiac Anomalies: A 10-Year Experience of an Interdisciplinary Program at a Large Tertiary Cardiac Center. J Pediatr 2019; 214:79-88. [PMID: 31655705 DOI: 10.1016/j.jpeds.2019.07.044] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Revised: 06/18/2019] [Accepted: 07/18/2019] [Indexed: 12/30/2022]
Abstract
OBJECTIVES To report the outcomes of a Neonatal Palliative Care (NPC) Program at a large tertiary cardiac center caring for a subset of fetuses and neonates with life-limiting cardiac diagnoses or cardiac diagnoses with medical comorbidities leading to adverse prognoses. STUDY DESIGN The Neonatal Comfort Care Program at New York-Presbyterian Morgan Stanley Children's Hospital/Columbia University Medical Center is an interdisciplinary team that offers the option of NPC to neonates prenatally diagnosed with life-limiting conditions, including single ventricle (SV) congenital heart disease (CHD) or less severe forms of CHD complicated by multiorgan dysfunction or genetic syndromes. RESULTS From 2008 to 2017, the Neonatal Comfort Care Program cared for 75 fetuses or neonates including 29 with isolated SV CHD, 36 with CHD and multiorgan dysfunction and/or severe genetic abnormalities, and 10 neonates with a prenatal diagnosis of isolated CHD and postnatal diagnoses of severe conditions who were initially in intensive care before transitioning to NPC because of a poor prognosis. CONCLUSIONS At New York-Presbyterian Morgan Stanley Children's Hospital/Columbia University Medical Center, a large tertiary cardiac center, 13.5% of parents of fetuses or neonates with isolated SV CHD opted for NPC. Twenty-six of 29 newborns with SV CHD treated with NPC died. Of the remaining, 2 neonates with mixing lesions are alive at 3 and 5 years of age, and 1 neonate was initially treated with NPC and then pursued surgical palliation. These results suggest that NPC is a reasonable choice for neonates with SV CHD.
Collapse
Affiliation(s)
- Caitlin Haxel
- Division of Pediatric Cardiology, Department of Pediatrics, Children's Hospital Colorado, University of Colorado Denver School of Medicine, Aurora, CO; Division of Pediatric Cardiology, Department of Pediatrics, NewYork-Presbyterian Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, NY.
| | - Julie Glickstein
- Division of Pediatric Cardiology, Department of Pediatrics, NewYork-Presbyterian Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, NY
| | - Elvira Parravicini
- Division of Pediatric Cardiology, Department of Pediatrics, NewYork-Presbyterian Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, NY
| |
Collapse
|
38
|
Ebrashy A, Aboulghar M, Elhodiby M, El-Dessouky SH, Elsirgany S, Gaafar HM, Sheta SS, Kamal R, Negm S, El Sheikhah A, Idris O, Abd-El-Kader M, Ehab M, Momtaz M. Fetal heart examination at the time of 13 weeks scan: a 5 years' prospective study. J Perinat Med 2019; 47:871-878. [PMID: 31494637 DOI: 10.1515/jpm-2019-0222] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Accepted: 07/26/2019] [Indexed: 12/22/2022]
Abstract
Objective To evaluate our ability in classifying the fetal heart as normal or abnormal during the 1st trimester scan through fetal cardiac examination and determining the best time for this examination. Methods This was a prospective study performed on 3240 pregnant women to examine the fetal heart. Four chambers view and ventricular outflow tracts were mainly examined during the scan. We used grayscale and color mapping in the diagnosis. Color Doppler was used if additional information was needed, and all patients were rescanned during the 2nd trimester to confirm or negate our diagnosis. Results The cardiac findings were normal at both scans in 3108 pregnancies. The same cardiac abnormality was detected at both scans in 79 cases. In 36 cases there was false-positive diagnosis at the early scan; in 20 of these cases, there were mildly abnormal functional findings early in pregnancy with no abnormality found later. In 17 fetuses, there was discordance between the early and later diagnosis due to missed or incorrect diagnoses. The best time to do fetal heart examination during 1st trimester is between 13 and 13 + 6 weeks. Conclusion A high degree of accuracy in the identification of congenital heart disease (CHD) can be achieved by a 1st trimester fetal echocardiography.
Collapse
Affiliation(s)
- Alaa Ebrashy
- Fetal Medicine Unit, Department of Obstetrics and Gynecology, Cairo University, Cairo 11435, Egypt
| | - Mona Aboulghar
- Fetal Medicine Unit, Department of Obstetrics and Gynecology, Cairo University, Cairo, Egypt
| | - Mohamed Elhodiby
- Department of Obstetrics and Gynecology, Faculty of Medicine, M.U.S.T. University, Cairo, Egypt
| | - Sara H El-Dessouky
- Prenatal Diagnosis and Fetal Medicine Department, Human Genetics and Genome Research Division, National Research Centre, Cairo, Egypt
| | - Sherif Elsirgany
- Reproductive Health Research Department, National Research Centre, Cairo, Egypt
| | - Hassan M Gaafar
- Fetal Medicine Unit, Department of Obstetrics and Gynecology, Cairo University, Cairo, Egypt
| | - Sahar S Sheta
- Department of Paediatrics, Cairo University, Cairo, Egypt
| | - Rasha Kamal
- Fetal Medicine Unit, Department of Obstetrics and Gynecology, Cairo University, Cairo, Egypt
| | - Sherif Negm
- Fetal Medicine Unit, Department of Obstetrics and Gynecology, Cairo University, Cairo, Egypt
| | - Ahmed El Sheikhah
- Fetal Medicine Unit, Department of Obstetrics and Gynecology, Cairo University, Cairo, Egypt
| | - Omaima Idris
- Fetal Medicine Unit, Department of Obstetrics and Gynecology, Cairo University, Cairo, Egypt
| | - Mohamed Abd-El-Kader
- Fetal Medicine Unit, Department of Obstetrics and Gynecology, Cairo University, Cairo, Egypt
| | - Mohamed Ehab
- Fetal Medicine Unit, Department of Obstetrics and Gynecology, Cairo University, Cairo, Egypt
| | - Mohamed Momtaz
- Fetal Medicine Unit, Department of Obstetrics and Gynecology, Cairo University, Cairo, Egypt
| |
Collapse
|
39
|
Jabak S, Vigneswaran TV, Charakida M, Kasapoglu T, de Jesus Cruz J, Simpson JM, Zidere V. Initial Experience of Superb Microvascular Imaging for Key Cardiac Views in Foetal Assessment before 15 Weeks Gestation. Fetal Diagn Ther 2019; 47:268-276. [PMID: 31597155 DOI: 10.1159/000502839] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Accepted: 08/21/2019] [Indexed: 11/19/2022]
Abstract
BACKGROUND In the first trimester, ultrasound confirmation of normal or abnormal cardiac anatomy is difficult. B-mode and colour flow Doppler (CFD) are used to assess the foetal heart. Superb microvascular imaging (SMI) can visualise blood flow within the heart and vessels in early gestation. OBJECTIVE We report an initial experience of SMI for visualisation of normal and abnormal cardiac anatomy in the first trimester. METHODS Transabdominal foetal echocardiography was performed between 11 + 6 and 14 + 3 weeks (Aplio 500 US system, Toshiba Medical Systems, Tokyo, Japan) from January 2017 to December 2017. All scans were performed at a tertiary foetal cardiology unit. To assess the potential utility of the technique for early gestation screening, normal scans were reviewed by foetal medicine trainees with respect to the B-mode, CFD and SMI. Three key views were selected to compare modalities: the 4-chamber view, outflow tracts and the 3-vessel and trachea view (VTV). Visualisation rates of key echocardiographic features of significant cardiac abnormalities by SMI were reviewed. RESULTS Fifty-five normal echocardiograms and 34 cardiac abnormalities were included. In the normal heart, when B-mode, CFD and SMI were assessed separately, SMI had the highest rate of visualisation of 4-chamber, outflow tracts and 3-VTV (93, 85 and 83%, respectively). Intra-observer reliability was moderate for SMI of the 3 standard views (kappa 1, 0.64 and 0.64); inter-observer for 4-chamber and outflow tract views was moderate (kappa 0.64 and 0.77). In 29/34 abnormal cases, SMI showed key features, enhancing greyscale visualisation. CONCLUSION SMI has potential to become a useful, complementary modality for early foetal echocardiography. Further prospective studies are warranted to establish the place of the technique in assessment of the first trimester foetal heart.
Collapse
Affiliation(s)
- Salma Jabak
- Harris Birthright Research Centre for Fetal Medicine, King's College Hospital, London, United Kingdom
| | - Trisha V Vigneswaran
- Harris Birthright Research Centre for Fetal Medicine, King's College Hospital, London, United Kingdom.,Department of Congenital Heart Disease, Evelina London Children's Hospital, Guy's and St. Thomas' Hospitals, London, United Kingdom
| | - Marietta Charakida
- School of Biomedical Engineering and Imaging Sciences, Kings College London, NIHR Biomedical Research Centre at Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Taner Kasapoglu
- Harris Birthright Research Centre for Fetal Medicine, King's College Hospital, London, United Kingdom
| | | | - John M Simpson
- Harris Birthright Research Centre for Fetal Medicine, King's College Hospital, London, United Kingdom.,Department of Congenital Heart Disease, Evelina London Children's Hospital, Guy's and St. Thomas' Hospitals, London, United Kingdom
| | - Vita Zidere
- Harris Birthright Research Centre for Fetal Medicine, King's College Hospital, London, United Kingdom, .,Department of Congenital Heart Disease, Evelina London Children's Hospital, Guy's and St. Thomas' Hospitals, London, United Kingdom,
| |
Collapse
|
40
|
Affiliation(s)
- Luke G Eckersley
- Fetal and Neonatal Cardiology Program, Echocardiography Laboratory, Division of Cardiology, Department of Pediatrics, University of Alberta, Edmonton, Canada (L.G.E., L.K.H.)
| | - Lisa K Hornberger
- Fetal and Neonatal Cardiology Program, Echocardiography Laboratory, Division of Cardiology, Department of Pediatrics, University of Alberta, Edmonton, Canada (L.G.E., L.K.H.).,Department of Obstetrics and Gynecology, Women and Children's Health Research, Mazankowski Alberta Heart Institutes, University of Alberta, Edmonton, Canada (L.K.H.)
| |
Collapse
|
41
|
Sileo FG, Carvalho JS. 'Just-flow' visualization of aortic arch in fetuses ≤ 16 weeks. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2019; 53:852-854. [PMID: 30740792 DOI: 10.1002/uog.20235] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Revised: 02/03/2019] [Accepted: 02/06/2019] [Indexed: 06/09/2023]
Affiliation(s)
- F G Sileo
- Fetal Medicine Unit, Department of Obstetrics and Gynaecology, St George's University Hospitals NHS Foundation Trust, London, UK
- Prenatal Medicine Unit, Obstetrics and Gynaecology Unit, Department of Medical and Surgical Sciences for Mother, Child and Adult, University of Modena and Reggio Emilia, Modena, Italy
| | - J S Carvalho
- Fetal Medicine Unit, Department of Obstetrics and Gynaecology, St George's University Hospitals NHS Foundation Trust, London, UK
- Molecular and Clinical Sciences Research Institute, St George's University of London, London, UK
- Brompton Centre for Fetal Cardiology, Royal Brompton Hospital, London, UK
| |
Collapse
|
42
|
Sandrini C, Lombardi C, Shearn AIU, Ordonez MV, Caputo M, Presti F, Luciani GB, Rossetti L, Biglino G. Three-Dimensional Printing of Fetal Models of Congenital Heart Disease Derived From Microfocus Computed Tomography: A Case Series. Front Pediatr 2019; 7:567. [PMID: 32039123 PMCID: PMC6985276 DOI: 10.3389/fped.2019.00567] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Accepted: 12/27/2019] [Indexed: 12/14/2022] Open
Abstract
This article presents a case series of n = 21 models of fetal cardiovascular anatomies obtained from post mortem microfocus computed tomography (micro-CT) data. The case series includes a broad range of diagnoses (e.g., tetralogy of Fallot, hypoplastic left heart syndrome, dextrocardia, double outlet right ventricle, atrio-ventricular septal defect) and cases also had a range of associated extra-cardiac malformations (e.g., VACTERL syndrome, central nervous system anomalies, renal anomalies). All cases were successfully reconstructed from the microfocus computed tomography data, demonstrating the feasibility of the technique and of the protocols, including in-house printing with a desktop 3D printer (Form2, Formlabs). All models were printed in 1:1 scale as well as with the 5-fold magnification, to provide insight into the intra-cardiac structures. Possible uses of the models include education and training.
Collapse
Affiliation(s)
- Camilla Sandrini
- Division of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | | | - Andrew I U Shearn
- Bristol Medical School, Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| | - Maria Victoria Ordonez
- Bristol Medical School, Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| | - Massimo Caputo
- Bristol Medical School, Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| | - Francesca Presti
- Division of Obstetrics and Gynecology B, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - Giovanni Battista Luciani
- Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - Lucia Rossetti
- Division of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | - Giovanni Biglino
- Bristol Medical School, Bristol Heart Institute, University of Bristol, Bristol, United Kingdom.,National Heart and Lung Institute, Imperial College London, London, United Kingdom
| |
Collapse
|
43
|
Sandrini C, Rossetti L, Zambelli V, Zanarotti R, Bettinazzi F, Soldá R, Di Pace C, Hoxha S, Ribichini FL, Faggian G, Lombardi C, Luciani GB. Accuracy of Micro-Computed Tomography in Post-mortem Evaluation of Fetal Congenital Heart Disease. Comparison Between Post-mortem Micro-CT and Conventional Autopsy. Front Pediatr 2019; 7:92. [PMID: 30968009 PMCID: PMC6440368 DOI: 10.3389/fped.2019.00092] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2018] [Accepted: 03/01/2019] [Indexed: 11/13/2022] Open
Abstract
Aims: Early prenatal diagnosis of congenital heart disease is feasible. Conventional autopsy is the current gold standard method for post-mortem confirmation. Radiologic techniques alternative to conventional autopsy, such as post-mortem micro-computed tomography, have been proposed in case of limited diagnostic accuracy (i.e., early termination of pregnancy, samples of small dimension or of low weight). The aim of the present study was to define accuracy of micro-computed tomography for post-mortem diagnosis of congenital heart disease in gross anatomy samples. Methods and Results: Fetal heart underwent in-utero prenatal echocardiography and ex-vivo post-mortem evaluation by 9 μm resolution micro-computed tomography and conventional autopsy. For each case, 25 indices of cardiac anatomy were studied by post-mortem micro-computed tomography and conventional autopsy; these were used to compare the two post mortem techniques. Ten samples were examined (gestational age between 12 + 4 and 21 + 6 weeks of gestation). Considering comparable indices, agreement between post-mortem micro-computed tomography and conventional autopsy was of 100% and sensitivity and specificity were of 100%. In "challenging specimens," post-mortem micro-computed tomography diagnoses more indices as compared to conventional autopsy and 84% of "not-diagnostic" indices at conventional autopsy would be diagnostic at post-mortem micro-computed tomography. Conclusion: Micro-computed tomography can be a valid diagnostic alternative to conventional autopsy for post-mortem evaluation of human fetal heart. In addition, it may prove superior to conventional autopsy particularly in cases coming from early termination of pregnancy or in samples of small dimension or of low weight.
Collapse
Affiliation(s)
- Camilla Sandrini
- Division of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | - Lucia Rossetti
- Division of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | - Vanessa Zambelli
- School of Medicine and Surgery, University of Milano Bicocca, Monza, Italy
| | | | - Franca Bettinazzi
- Division of Obstetrics and Gynecology, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - Roberta Soldá
- Division of Obstetrics and Gynecology, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - Concetta Di Pace
- Department of Pathology, Department of Diagnostics and Public Health, University of Verona, Verona, Italy
| | - Stiljan Hoxha
- Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | | | - Giuseppe Faggian
- Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | | | - Giovanni Battista Luciani
- Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| |
Collapse
|
44
|
The pregnancy experience of Korean mothers with a prenatal fetal diagnosis of congenital heart disease. BMC Pregnancy Childbirth 2018; 18:467. [PMID: 30509236 PMCID: PMC6276209 DOI: 10.1186/s12884-018-2117-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2017] [Accepted: 11/22/2018] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND Prenatal diagnosis of fetal congenital heart disease (CHD) is becoming widely available but there is a lack of understanding on such expectant mothers' experiences during pregnancy. This was the first study to investigate the pregnancy experience of Korean mothers with a prenatal fetal diagnosis of CHD. METHODS In-depth interviews were conducted with 12 mothers regarding their child's prenatal diagnosis of CHD and the adaptive processes during pregnancy. The data were transcribed and analyzed according to the grounded theory framework. RESULTS When the diagnosis of fetal CHD was suspected, mothers desperately sought accurate information regarding CHD while hoping in vain for a misdiagnosis. When the definitive diagnosis was made, most pregnant women experienced psychological trauma and pain, framed in the stigma and burden of having an imperfect child. Provision of accurate health advice and emotional support by a multidisciplinary counseling team was crucial at this phase, forming recognition that CHD could be treated. When fetal movements were felt, mothers came to acknowledge the fetus as an independent being, and made their best efforts to protect the fetus from harmful external influences using traditional TaeKyo mindset and practices, which in turn, were helpful in restructuring the meaning of the pregnancy. CONCLUSIONS Mothers went through a dynamic process of adapting to the unexpected diagnosis of CHD, which was closely linked to being able to believe that their child could be treated. Early counseling with precise information on CHD, continuous provision of clear explanations on prognosis, sufficient emotional support, and well-designed prenatal education programs are the keys to an optimal outcome.
Collapse
|
45
|
McBrien A, Hornberger LK. Early fetal echocardiography. Birth Defects Res 2018; 111:370-379. [PMID: 30430770 DOI: 10.1002/bdr2.1414] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2018] [Accepted: 09/27/2018] [Indexed: 11/09/2022]
Abstract
OBJECTIVES To explore the technical aspects and clinical utility of early fetal echocardiography and screening of the fetal heart in early pregnancy. Also, to document differences in cardiac structure and function which can be demonstrated in the late first/early second trimesters. METHODS In addition to summarizing our own experiences of late first/early second trimester fetal echocardiography, we reviewed the literature to explore clinical indications for, technical aspects, safety, accuracy, strengths and weaknesses of early fetal echocardiography. RESULTS In the current era, an increasing number of fetuses are identified as being at risk of congenital heart disease from as early as the late first trimester. In experienced hands, early fetal echocardiography can pick up a high proportion of congenital heart disease with good reliability for the majority of lesions. Early fetal echocardiography is relatively poor at assessing pulmonary veins, the atrioventricular valves and lesions that typically occur later or progress during the course of pregnancy. There is increasing interest in widespread implementation of an early obstetric anomaly screen which includes an assessment of the fetal heart for all pregnancies. There are a variety of hemodynamic differences in the late first/early second trimester compared with later in pregnancy. CONCLUSION Early fetal echocardiography is has become an established tool for detection of congenital heart disease. It affords opportunities to learn about the true spectrum and progression of congenital heart disease in-utero. Operators should be mindful of safety issues, technical aspects and hemodynamic findings which differ when performing echocardiograms at this stage of pregnancy.
Collapse
Affiliation(s)
- Angela McBrien
- Fetal & Neonatal Cardiology Program, Division of Cardiology, Department of Pediatrics, Stollery Children's Hospital, Edmonton, Alberta, Canada.,Women and Children's Health Research Institute, Cardiovascular Research Institute, University of Alberta, Edmonton, Alberta, Canada
| | - Lisa K Hornberger
- Fetal & Neonatal Cardiology Program, Division of Cardiology, Department of Pediatrics, Stollery Children's Hospital, Edmonton, Alberta, Canada.,Women and Children's Health Research Institute, Cardiovascular Research Institute, University of Alberta, Edmonton, Alberta, Canada.,The Department of Obstetrics and Gynecology, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
46
|
Abstract
The development of fetal echocardiography and success in prenatal cardiac screening programs over the past 30 years has been driven by technical innovation and influenced by the different approaches of the various specialties practicing it. Screening for congenital heart defects no longer focuses on examining a limited number of pregnant women thought to be at increased risk, but instead forms an integrated part of a high-quality anatomical ultrasound performed in the second trimester using the 'five-transverse view' protocol. A prenatal diagnosis is feasible in almost all cardiac lesions and the advantages to parents and to health professionals are well recognized. Prenatal evaluation can usually determine the level of care required at delivery, thereby reducing perinatal morbidity. However, only half of the babies undergoing surgery within the first year of life have a prenatal detection, and practical training programs to support and provide feedback to sonographers remain essential for continued improvement.
Collapse
Affiliation(s)
- Helena M Gardiner
- The Fetal Center at Children's Memorial Hermann Hospital, McGovern Medical School at UTHealth, The University of Texas Health Sciences Center at Houston, Houston TX, USA.
| |
Collapse
|