1
|
Fluorine-containing bio-inert polymers: Roles of intermediate water. Acta Biomater 2022; 138:34-56. [PMID: 34700043 DOI: 10.1016/j.actbio.2021.10.027] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 10/06/2021] [Accepted: 10/18/2021] [Indexed: 12/13/2022]
Abstract
Fluorine-containing polymers are used not only in industrial processes but also in medical applications, because they exhibit excellent heat, weather, and chemical resistance. As these polymers are not easily degraded in our body, it is difficult to use them in applications that require antithrombotic properties, such as artificial blood vessels. The material used for medical applications should not only be stable in vivo, but it should also be inert to biomolecules such as proteins or cells. In this review, this property is defined as "bio-inert," and previous studies in this field are summarized. Bio-inert materials are less recognized as foreign substances by proteins or cells in the living body, and they must be covered at interfaces designed with the concept of intermediate water (IW). On the basis of this concept, we present here the current understanding of bio-inertness and unusual blood compatibility found in fluoropolymers used in biomedical applications. IW is the water that interacts with materials with moderate strength and has been quantified by a variety of analytical methods and simulations. For example, by using differential scanning calorimetry (DSC) measurements, IW was defined as water frozen at around -40°C. To consider the role of the IW, quantification methods of the hydration state of polymers are also summarized. These investigations have been conducted independently because of the conflict between hydrophobic fluorine and bio-inert properties that require hydrophilicity. In recent years, not many materials have been developed that incorporate the good points of both aspects, and their properties have seldom been linked to the hydration state. This has been critically performed now. Furthermore, fluorine-containing polymers in medical use are reviewed. Finally, this review also describes the molecular design of the recently reported fluorine-containing bio-inert polymers for controlling their hydration state. STATEMENT OF SIGNIFICANCE: A material covered with a hydration layer known as intermediate water that interacts moderately with other objects is difficult to be recognized as a foreign substance and exhibits bio-inert properties. Fluoropolymers show high durability, but conflict with bio-inert characteristics requiring hydrophilicity as these research studies have been conducted independently. On the other hand, materials that combine the advantages of both hydrophobic and hydrophilic features have been developed recently. Here, we summarize the molecular architecture and analysis methods that control intermediate water and provide a guideline for designing novel fluorine-containing bio-inert materials.
Collapse
|
2
|
Tanaka T, Ibe Y, Jono T, Tanaka R, Naito A, Asakura T. Characterization of a Water-Dispersed Biodegradable Polyurethane-Silk Composite Sponge Using 13C Solid-State Nuclear Magnetic Resonance as Coating Material for Silk Vascular Grafts with Small Diameters. Molecules 2021; 26:4649. [PMID: 34361802 PMCID: PMC8347230 DOI: 10.3390/molecules26154649] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 07/12/2021] [Accepted: 07/27/2021] [Indexed: 11/30/2022] Open
Abstract
Recently, Bombyx mori silk fibroin (SF) has been shown to be a suitable material for vascular prostheses for small arteries. In this study, we developed a softer SF graft by coating water-dispersed biodegradable polyurethane (PU) based on polycaprolactone and an SF composite sponge on the knitted SF vascular graft. Three kinds of 13C solid-state nuclear magnetic resonance (NMR), namely carbon-13 (13C) cross-polarization/magic angle spinning (MAS), 13C dipolar decoupled MAS, and 13C refocused insensitive nuclei enhanced by polarization transfer (r-INEPT) NMR, were used to characterize the PU-SF coating sponge. Especially the 13C r-INEPT NMR spectrum of water-dispersed biodegradable PU showed that both main components of the non-crystalline domain of PU and amorphous domain of SF were highly mobile in the hydrated state. Then, the small-diameter SF artificial vascular grafts coated with this sponge were evaluated through implantation experiments with rats. The implanted PU-SF-coated SF grafts showed a high patency rate. It was confirmed that the inside of the SF grafts was covered with vascular endothelial cells 4 weeks after implantation. These results showed that the water-dispersed biodegradable PU-SF-coated SF graft created in this study could be a strong candidate for small-diameter artificial vascular graft.
Collapse
Affiliation(s)
- Takashi Tanaka
- Department of Veterinary Science, Tokyo University of Agriculture and Technology, Tokyo 183-8509, Japan; (T.T.); (R.T.)
| | - Yusuke Ibe
- Polyurethane Research Laboratory, Tosoh Corporation, Mie 510-8540, Japan; (Y.I.); (T.J.)
| | - Takaki Jono
- Polyurethane Research Laboratory, Tosoh Corporation, Mie 510-8540, Japan; (Y.I.); (T.J.)
| | - Ryo Tanaka
- Department of Veterinary Science, Tokyo University of Agriculture and Technology, Tokyo 183-8509, Japan; (T.T.); (R.T.)
| | - Akira Naito
- Department of Biotechnology, Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan;
| | - Tetsuo Asakura
- Department of Biotechnology, Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan;
| |
Collapse
|
3
|
Wacker M, Riedel J, Walles H, Scherner M, Awad G, Varghese S, Schürlein S, Garke B, Veluswamy P, Wippermann J, Hülsmann J. Comparative Evaluation on Impacts of Fibronectin, Heparin-Chitosan, and Albumin Coating of Bacterial Nanocellulose Small-Diameter Vascular Grafts on Endothelialization In Vitro. NANOMATERIALS 2021; 11:nano11081952. [PMID: 34443783 PMCID: PMC8398117 DOI: 10.3390/nano11081952] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 07/22/2021] [Accepted: 07/25/2021] [Indexed: 12/18/2022]
Abstract
In this study, we contrast the impacts of surface coating bacterial nanocellulose small-diameter vascular grafts (BNC-SDVGs) with human albumin, fibronectin, or heparin–chitosan upon endothelialization with human saphenous vein endothelial cells (VEC) or endothelial progenitor cells (EPC) in vitro. In one scenario, coated grafts were cut into 2D circular patches for static colonization of a defined inner surface area; in another scenario, they were mounted on a customized bioreactor and subsequently perfused for cell seeding. We evaluated the colonization by emerging metabolic activity and the preservation of endothelial functionality by water soluble tetrazolium salts (WST-1), acetylated low-density lipoprotein (AcLDL) uptake assays, and immune fluorescence staining. Uncoated BNC scaffolds served as controls. The fibronectin coating significantly promoted adhesion and growth of VECs and EPCs, while albumin only promoted adhesion of VECs, but here, the cells were functionally impaired as indicated by missing AcLDL uptake. The heparin–chitosan coating led to significantly improved adhesion of EPCs, but not VECs. In summary, both fibronectin and heparin–chitosan coatings could beneficially impact the endothelialization of BNC-SDVGs and might therefore represent promising approaches to help improve the longevity and reduce the thrombogenicity of BNC-SDVGs in the future.
Collapse
Affiliation(s)
- Max Wacker
- Department of Cardiothoracic Surgery, University Hospital Magdeburg, 39112 Magdeburg, Germany; (J.R.); (M.S.); (G.A.); (S.V.); (P.V.); (J.W.); (J.H.)
- Correspondence: ; Tel.: +49-391-67-14102
| | - Jan Riedel
- Department of Cardiothoracic Surgery, University Hospital Magdeburg, 39112 Magdeburg, Germany; (J.R.); (M.S.); (G.A.); (S.V.); (P.V.); (J.W.); (J.H.)
| | - Heike Walles
- Core Facility Tissue Engineering, Otto-Von-Guericke University Magdeburg, 39106 Magdeburg, Germany;
| | - Maximilian Scherner
- Department of Cardiothoracic Surgery, University Hospital Magdeburg, 39112 Magdeburg, Germany; (J.R.); (M.S.); (G.A.); (S.V.); (P.V.); (J.W.); (J.H.)
| | - George Awad
- Department of Cardiothoracic Surgery, University Hospital Magdeburg, 39112 Magdeburg, Germany; (J.R.); (M.S.); (G.A.); (S.V.); (P.V.); (J.W.); (J.H.)
| | - Sam Varghese
- Department of Cardiothoracic Surgery, University Hospital Magdeburg, 39112 Magdeburg, Germany; (J.R.); (M.S.); (G.A.); (S.V.); (P.V.); (J.W.); (J.H.)
| | - Sebastian Schürlein
- Department Tissue Engineering and Regenerative Medicine (TERM), University Hospital Würzburg, 97070 Würzburg, Germany;
| | - Bernd Garke
- Institute of Experimental Physics, Otto-Von-Guericke University Magdeburg, 39106 Magdeburg, Germany;
| | - Priya Veluswamy
- Department of Cardiothoracic Surgery, University Hospital Magdeburg, 39112 Magdeburg, Germany; (J.R.); (M.S.); (G.A.); (S.V.); (P.V.); (J.W.); (J.H.)
| | - Jens Wippermann
- Department of Cardiothoracic Surgery, University Hospital Magdeburg, 39112 Magdeburg, Germany; (J.R.); (M.S.); (G.A.); (S.V.); (P.V.); (J.W.); (J.H.)
| | - Jörn Hülsmann
- Department of Cardiothoracic Surgery, University Hospital Magdeburg, 39112 Magdeburg, Germany; (J.R.); (M.S.); (G.A.); (S.V.); (P.V.); (J.W.); (J.H.)
| |
Collapse
|
4
|
Tanaka T, Abe Y, Cheng CJ, Tanaka R, Naito A, Asakura T. Development of Small-Diameter Elastin-Silk Fibroin Vascular Grafts. Front Bioeng Biotechnol 2021; 8:622220. [PMID: 33585421 PMCID: PMC7874157 DOI: 10.3389/fbioe.2020.622220] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Accepted: 12/15/2020] [Indexed: 11/13/2022] Open
Abstract
Globally, increasing mortality from cardiovascular disease has become a problem in recent years. Vascular replacement has been used as a treatment for these diseases, but with blood vessels <6 mm in diameter, existing vascular grafts made of synthetic polymers can be occluded by thrombus formation or intimal hyperplasia. Therefore, the development of new artificial vascular grafts is desirable. In this study, we developed an elastin (EL)-silk fibroin (SF) double-raschel knitted vascular graft 1.5 mm in diameter. Water-soluble EL was prepared from insoluble EL by hydrolysis with oxalic acid. Compared to SF, EL was less likely to adhere to platelets, while vascular endothelial cells were three times more likely to adhere. SF artificial blood vessels densely packed with porous EL were fabricated, and these prevented the leakage of blood from the graft during implantation, while the migration of cells after implantation was promoted. Several kinds of 13C solid-state NMR spectra were observed with the EL-SF grafts in dry and hydrated states. It was noted that the EL molecules in the graft had very high mobility in the hydrated state. The EL-SF grafts were implanted into the abdominal aorta of rats to evaluate their patency and remodeling ability. No adverse reactions, such as bleeding at the time of implantation or disconnection of the sutured ends, were observed in the implanted grafts, and all were patent at the time of extraction. In addition, vascular endothelial cells were present on the graft's luminal surface 2 weeks after implantation. Therefore, we conclude that EL-SF artificial vascular grafts may be useful where small-diameter grafts are required.
Collapse
Affiliation(s)
- Takashi Tanaka
- Department of Veterinary Surgery, Tokyo University of Agriculture & Technology, Fuchu, Japan
| | - Yasuyuki Abe
- Department of Biotechnology, Tokyo University of Agriculture & Technology, Koganei, Japan
| | - Chieh-Jen Cheng
- Department of Veterinary Medicine, College of Bioresource Sciences, Nihon University, Fujisawa, Japan
| | - Ryo Tanaka
- Department of Veterinary Surgery, Tokyo University of Agriculture & Technology, Fuchu, Japan
| | - Akira Naito
- Department of Biotechnology, Tokyo University of Agriculture & Technology, Koganei, Japan
| | - Tetsuo Asakura
- Department of Biotechnology, Tokyo University of Agriculture & Technology, Koganei, Japan
| |
Collapse
|
5
|
Zheng W, Liu M, Qi H, Wen C, Zhang C, Mi J, Zhou X, Zhang L, Fan D. Mussel-inspired triblock functional protein coating with endothelial cell selectivity for endothelialization. J Colloid Interface Sci 2020; 576:68-78. [DOI: 10.1016/j.jcis.2020.04.116] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Revised: 04/21/2020] [Accepted: 04/28/2020] [Indexed: 12/19/2022]
|
6
|
Yin A, Lan X, Zhuang W, Tang Z, Li Y, Wang Y. PEGylated chitosan and PEGylated PLCL for blood vessel repair: An in vitro study. J Biomater Appl 2019; 34:778-789. [DOI: 10.1177/0885328219875937] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Anlin Yin
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, China
- College of Materials and Textile Engineering, Jiaxing University, Jiaxing, China
| | - Xiaorong Lan
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, China
| | - Weihua Zhuang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, China
| | - Zhonglan Tang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, China
| | - Yan Li
- College of Architecture and Environment, Sichuan University, Chengdu, China
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, China
| |
Collapse
|
7
|
Liu Y, Munisso MC, Mahara A, Kambe Y, Fukazawa K, Ishihara K, Yamaoka T. A surface graft polymerization process on chemically stable medical ePTFE for suppressing platelet adhesion and activation. Biomater Sci 2018; 6:1908-1915. [PMID: 29877532 DOI: 10.1039/c8bm00364e] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
An effective surface grafting method for chemically inert and elaborately porous medical expanded-polytetrafluoroethylene (ePTFE) was developed. Although surface graft polymerization onto basic polymeric biomaterials has been widely studied, successful modification of the ePTFE surface has been lacking due to its high chemical resistance. Herein, we succeeded in surface graft polymerization onto ePTFE through glycidyl methacrylate (GMA) as a bridge linkage following argon (Ar) plasma treatment. The epoxy group of GMA was expected to react with the peroxide groups produced on ePTFE by Ar plasma exposure, and its methacrylic groups can copolymerize with various monomers. In the present study, we selected 2-methacryloyloxyethyl phosphorylcholine (MPC) as a model monomer and the blood compatibility of modified ePTFE was evaluated. Two sequences of surface grafting were compared. In a two-step graft polymerization, GMA was first immobilized onto Ar plasma treated ePTFE, and then MPC was polymerized. In a one-step graft copolymerization, MPC and GMA were mixed and copolymerized simultaneously onto Ar plasma treated ePTFE, resulting in a poly(MPC-co-GMA) (PMG) graft surface. The roughness of the node-and-fibril structure of ePTFE was reduced by the uniform polymer layer, and the modified ePTFE had a good hydrophilic nature even after being stored in an aqueous environment for 30 days. The indispensable GMA in graft polymerization improved the surface grafting on ePTFE. The one-step and two-step graft polymerization methods could decrease the number of adhered platelets, and almost inhibit platelet activation. We concluded that graft polymerization with the GMA linker provides a novel strategy to modify the chemically inert ePTFE surfaces for functionalizing as new medical devices.
Collapse
Affiliation(s)
- Yihua Liu
- Department of Biomedical Engineering, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, Suita, Osaka 565-8565, Japan.
| | | | | | | | | | | | | |
Collapse
|
8
|
Tanaka T, Uemura A, Tanaka R, Tasei Y, Asakura T. Comparison of the knitted silk vascular grafts coated with fibroin sponges prepared using glycerin, poly(ethylene glycol diglycidyl ether) and poly(ethylene glycol) as porogens. J Biomater Appl 2018; 32:1239-1252. [PMID: 29448867 DOI: 10.1177/0885328218758276] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Development of a small-diameter artificial vascular graft is urgent because existing materials often occlude within a short time. We have shown that small-diameter vascular graft using Bombyx mori silk fibroin is a potential candidate. Silk fibroin grafts are fabricated by coating silk fibroin on the knit tube prepared from silk fibroin fibers. However, there is a serious problem that the coated silk fibroin portion hardens when alcohol is used for insolubilization of the coated silk fibroin. This hardening prevents the desired biodegradation of the coated silk fibroin. In this study, we improved the silk fibroin coating method of the knit silk fibroin tube. Namely, the silk fibroin sponge coating was performed using glycerin, poly(ethylene glycol diglycidyl ether) or poly(ethylene glycol). In addition, silk fibroin grafts were prepared avoiding dryness during the coating process and were kept in the hydrated state until implantation into the abdominal aorta was complete. After implantation of the hydrated silk fibroin grafts, grafts were taken out at two weeks or three months, and histopathological examination was performed. The grafts coated with three types of silk fibroin sponges had a higher tissue infiltration rate than alcohol-treated grafts and were superior in the formation of smooth muscle cell and vascular endothelial cell remodeling. Biodegradations of the silk fibroin grafts prepared using the three types of silk fibroin sponge coatings and alcohol-treated silk fibroin grafts were also examined with protease XIV in vitro, and the grafts were observed by scanning electron microscopy before and 24 h after biodegradation. Faster biodegradations were observed for grafts coated with the three types of silk fibroin sponges. 13C solid-state nuclear magnetic resonance studies showed that the conformation of the silk fibroin sponge prepared using porogen was a random coil with high mobility in the hydrated state. We believe that small-diameter silk fibroin vascular grafts coated with quick biodegradable silk fibroin sponges can be developed based on these findings.
Collapse
Affiliation(s)
- Takashi Tanaka
- 1 Veterinary Surgery, Tokyo University of Agriculture & Technology, Tokyo, Japan
| | - Akiko Uemura
- 1 Veterinary Surgery, Tokyo University of Agriculture & Technology, Tokyo, Japan
| | - Ryo Tanaka
- 1 Veterinary Surgery, Tokyo University of Agriculture & Technology, Tokyo, Japan
| | - Yugo Tasei
- 2 Biotechnology, Tokyo University of Agriculture & Technology, Tokyo, Japan
| | - Tetsuo Asakura
- 2 Biotechnology, Tokyo University of Agriculture & Technology, Tokyo, Japan
| |
Collapse
|
9
|
The effect of hirudin modification of silk fibroin on cell growth and antithrombogenicity. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 75:237-246. [DOI: 10.1016/j.msec.2017.02.035] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 12/15/2016] [Accepted: 02/08/2017] [Indexed: 01/14/2023]
|
10
|
Fukayama T, Takagi K, Tanaka R, Hatakeyama Y, Aytemiz D, Suzuki Y, Asakura T. Biological reaction to small-diameter vascular grafts made of silk fibroin implanted in the abdominal aortae of rats. Ann Vasc Surg 2014; 29:341-52. [PMID: 25449988 DOI: 10.1016/j.avsg.2014.10.008] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Revised: 10/02/2014] [Accepted: 10/02/2014] [Indexed: 11/28/2022]
Abstract
BACKGROUND Bombyx mori silk fibroin (SF) is biocompatible and degradable and has been proposed as a new material for small-diameter vascular grafts. We compared biological reactions to vascular grafts made of SF and polyethylene terephthalate (PET) to reveal the potential ability of SF as a base and/or coating materials for vascular prostheses. METHODS SF was combined with PET or gelatin (G) to make 4 types of vascular grafts (SF/SF, SF/G, PET/SF, and PET/G, shown as "base/coating material," respectively), which are 1.5 mm in diameter and 10 mm in length. The 4 types of grafts (n = 6, respectively) were implanted into rat abdominal aortae and explanted 2 weeks or 3 months later. RESULTS Two weeks after implantation, there are no significant differences among the 4 kinds of grafts in biological reactions evaluated by histopathologic examination. However, a remarkable difference was observed after 3 months. The area of tissue infiltration into the inside of the graft wall was approximately 2.5 times larger in SF/SF than that in PET/G. The endothelialization was achieved almost 100% in SF/SF, despite only 50% was achieved in PET/G. CONCLUSIONS Results show that SF has a higher potential as a base of vascular grafts than the commercially available PET/G graft. The larger tissue infiltration area in PET/SF compared with that in PET/G also indicates the potential of SF as a coating material. In the present study, SF delivered promising results as base and coating materials for small-diameter vascular prostheses.
Collapse
Affiliation(s)
- Toshiharu Fukayama
- Department of Veterinary Surgery, Tokyo University of Agriculture and Technology, Fuchu, Tokyo, Japan
| | - Keisuke Takagi
- Department of Veterinary Surgery, Tokyo University of Agriculture and Technology, Fuchu, Tokyo, Japan
| | - Ryou Tanaka
- Department of Veterinary Surgery, Tokyo University of Agriculture and Technology, Fuchu, Tokyo, Japan.
| | - Yui Hatakeyama
- Department of Biotechnology, Tokyo University of Agriculture and Technology, Koganei, Tokyo, Japan
| | - Derya Aytemiz
- Department of Biotechnology, Tokyo University of Agriculture and Technology, Koganei, Tokyo, Japan
| | - Yu Suzuki
- Department of Biotechnology, Tokyo University of Agriculture and Technology, Koganei, Tokyo, Japan
| | - Tetsuo Asakura
- Department of Biotechnology, Tokyo University of Agriculture and Technology, Koganei, Tokyo, Japan
| |
Collapse
|
11
|
Porcine carotid artery replacement with biodegradable electrospun poly-e-caprolactone vascular prosthesis. J Vasc Surg 2014; 59:210-9. [DOI: 10.1016/j.jvs.2013.03.004] [Citation(s) in RCA: 73] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2012] [Revised: 02/15/2013] [Accepted: 03/04/2013] [Indexed: 11/17/2022]
|
12
|
Vlachovsky R, Staffa R, Dvorak M, Vlasin M, Hermanova M, O'Brien T, McGloughlin T. Evaluation of a novel vascular graft with a distal bifurcation designed to reduce the development of intimal hyperplasia. Experimental study in a porcine aorta model. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2013; 158:562-8. [PMID: 23579111 DOI: 10.5507/bp.2013.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2012] [Accepted: 03/12/2013] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE Abnormal haemodynamics is commonly agreed to be a major contributor to the development of distal anastomotic intimal hyperplasia. A new vascular graft design proposed by computational studies was used to demonstrate its surgical feasibility and to compare it with the conventional graft in a porcine model. METHOD The device was used in 12 eight-month-old pigs, six received the new graft and six had a conventional graft. The proximal graft end was implanted into the aorta, the distal graft end was implanted into the iliac artery. The host artery was ligated in order to simulate occlusion. At 20 weeks after surgery the pigs were killed and the device was excised for histological and morphometric analysis. RESULTS In five experimental grafts the reconstruction was occluded due to thrombosis; only one prosthesis was patent showing a minimum of neointimal hyperplasia. In the control group too only three of the six grafts were patent. A histological analysis revealed, as the cause of occlusion, fibrous tissue overgrowth corresponding in structure to neointimal hyperplasia. Differences in the number of obliterations and in occlusion rates between the profiles of the two groups were evaluated using the median test (P<0.05). The results were not statistically significant. CONCLUSION Although mathematical modelling had shown significant haemodynamic benefits of a naturally bifurcated graft, our study did not confirm its superiority over conventionally used prostheses.
Collapse
Affiliation(s)
- Robert Vlachovsky
- Second Department of Surgery, St. Anne's University Hospital in Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | | | | | | | | | | | | |
Collapse
|
13
|
Min S, Gao X, Liu L, Tian L, Zhu L, Zhang H, Yao J. Fabrication and Characterization of Porous Tubular Silk Fibroin Scaffolds. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2012; 20:1961-74. [DOI: 10.1163/156856208x396056] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Affiliation(s)
- Sijia Min
- a College of Animal Sciences, Zhejiang University, Kaixuan Road 268, Hangzhou 310029, P. R. China.
| | - Xin Gao
- b College of Animal Sciences, Zhejiang University, Kaixuan Road 268, Hangzhou 310029, P. R. China
| | - Lin Liu
- c The Key Laboratory of Advanced Textile Materials and Manufacturing Technology of Ministry of Education, College of Materials and Textile, Zhejiang Sci-Tech University, Hangzhou 310018, P. R. China
| | - Li Tian
- d College of Animal Sciences, Zhejiang University, Kaixuan Road 268, Hangzhou 310029, P. R. China
| | - Liangjun Zhu
- e College of Animal Sciences, Zhejiang University, Kaixuan Road 268, Hangzhou 310029, P. R. China
| | - Haiping Zhang
- f College of Animal Sciences, Zhejiang University, Kaixuan Road 268, Hangzhou 310029, P. R. China
| | - Juming Yao
- g The Key Laboratory of Advanced Textile Materials and Manufacturing Technology of Ministry of Education, College of Materials and Textile, Zhejiang Sci-Tech University, Hangzhou 310018, P. R. China
| |
Collapse
|
14
|
Tatterton M, Wilshaw SP, Ingham E, Homer-Vanniasinkam S. The use of antithrombotic therapies in reducing synthetic small-diameter vascular graft thrombosis. Vasc Endovascular Surg 2012; 46:212-22. [PMID: 22308212 DOI: 10.1177/1538574411433299] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Thrombosis of synthetic small-diameter bypass grafts remains a major problem. The aim of this article is to review the antithrombotic strategies that have been used in an attempt to reduce graft thrombogenicity. METHODS A PubMed/MEDLINE search was performed using the search terms "vascular graft thrombosis," "small-diameter graft thrombosis," "synthetic graft thrombosis" combined with "antithrombotic," "antiplatelet," "anticoagulant," "Dacron," "PTFE," and "polyurethane." RESULTS The majority of studies on antithrombotic therapies have used either in vitro models or in vivo animal experiments. Many of the therapies used in these settings do show antithrombotic efficacy against synthetic graft materials. There is however, a distinct lack of human in vivo studies to further delineate the performance and limitations of therapies displaying good antithrombotic characteristics. CONCLUSION Very few antithrombotic therapies have translated into clinical use. More human in vivo studies are required to assess the efficacy and safety of such therapies.
Collapse
Affiliation(s)
- Mark Tatterton
- Leeds Vascular Institute, Leeds General Infirmary, Leeds, Yorkshire, UK.
| | | | | | | |
Collapse
|
15
|
Bacakova L, Filova E, Parizek M, Ruml T, Svorcik V. Modulation of cell adhesion, proliferation and differentiation on materials designed for body implants. Biotechnol Adv 2011; 29:739-67. [PMID: 21821113 DOI: 10.1016/j.biotechadv.2011.06.004] [Citation(s) in RCA: 561] [Impact Index Per Article: 43.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2011] [Revised: 05/30/2011] [Accepted: 06/09/2011] [Indexed: 12/12/2022]
Affiliation(s)
- Lucie Bacakova
- Department of Growth and Differentiation of Cell Populations, Institute of Physiology, Academy of Sciences of the Czech Republic, Videnska 1082, 14220 Prague 4-Krc, Czech Republic.
| | | | | | | | | |
Collapse
|
16
|
Heidenhain C, Veeravoorn A, Vachkov B, Weichert W, Schmidmaier G, Wildemann B, Neuhaus P, Heise M. Fibroblast and vascular endothelial growth factor coating of decellularized vascular grafts stimulates undesired giant cells and graft encapsulation in a rat model. Artif Organs 2010; 35:E1-10. [PMID: 20883449 DOI: 10.1111/j.1525-1594.2010.01072.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Replacing an infected prosthesis with a bioimplant provides a hopeful alternative in septic vascular surgery. The objective of this study was to determine the effect of fibroblast endothelial growth factors (FGF) and vascular endothelial growth factors (VEGF) coating on a decellularized vascular graft in a rat model and the possible impact on recellularization processes. Rat aortas were decellularized, crosslinked with genipin, and coated with poly-(D, L) lactide containing either FGF or VEGF. Observation periods were 6 and 12 weeks. Surprisingly, we found moderate accumulation of giant cells around the grafts that contained poly-(D, L) lactide acid. FGF and VEGF grafts showed massive stimulation of giant cells and eosinophils leading to complete graft encapsulation (P < 0.05). Pseudointmal hyperplasia was significantly increased in the FGF group (P < 0.05). Both results can only be interpreted as very negative. We achieved a situation in diametric opposition to that which we had hoped for. These data demonstrate that the use of growth factors may produce harmful side effects.
Collapse
Affiliation(s)
- Christoph Heidenhain
- Department of General, Visceral and Transplantation Surgery, Charité, Campus Virchow, University Medicine Berlin, Berlin, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Heidenhain C, Weichert W, Schmidmaier G, Wildemann B, Hein M, Neuhaus P, Heise M. Polymer coating of porcine decellularized and cross-linked aortic grafts. J Biomed Mater Res B Appl Biomater 2010; 94:256-63. [PMID: 20524202 DOI: 10.1002/jbm.b.31650] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This article investigates a method of modifying and optimizing the biocompatibility of decellularized vascular bioimplants when treated with a specialized, drug eluting coating. For this purpose, we carried out aortic transplantations using a porcine model. Decellularized, cross-linked aortic grafts were coated with poly(D,L-lactide) (PDLLA). To this coating, we added the anticoagulant drug lepirudin which, following transplantation, would be linearly eluted. These aortic grafts are easily manipulated in surgery. It was shown that, as a result of the lepirudin-eluting coating, the rate of thrombogenesis was reduced and the patency rate was significantly improved. However, lumen-stenosing pseudointima developed in all of the transplants and was not effected by PDLLA coating. Furthermore, no evidence of recellularisation was documented. This trial demonstrates that polymer coating of decellularized tissue is possible. Neointimal hyperplasia and the absence of cellular repopulation mark the negative consequences of this concept.
Collapse
Affiliation(s)
- Christoph Heidenhain
- Department of General, Visceral and Transplantation Surgery, Charité, Campus Virchow, University Medicine Berlin, Berlin 13353, Germany.
| | | | | | | | | | | | | |
Collapse
|
18
|
Allen JB, Khan S, Lapidos KA, Ameer GA. Toward engineering a human neoendothelium with circulating progenitor cells. Stem Cells 2010; 28:318-28. [PMID: 20013827 DOI: 10.1002/stem.275] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Tissue-engineered vascular grafts may one day provide a solution to many of the limitations associated with using synthetic vascular grafts. However, identifying a suitable cell source and polymer scaffold to recreate the properties of a native blood vessel remains a challenge. In this work, we assess the feasibility of using endothelial progenitor cells (EPCs) found in circulating blood to generate a functional endothelium on poly(1,8-octanediol-co-citrate) (POC), a biodegradable elastomeric polyester. EPCs were isolated from human blood and biochemically differentiated into endothelial-like cells (HE-like) in vitro. The differentiated cell phenotype and function was confirmed by the appearance of the characteristic endothelial cell (EC) cobblestone morphology and positive staining for EC markers, von Willebrand factor, vascular endothelial cadherin, flk-1, and CD31. In addition, HE-like cells cultured on POC express endothelial nitric oxide synthase at levels comparable to aortic ECs. Furthermore, as with mature endothelial cells, HE-like cell populations show negligible expression of tissue factor. Similarly, HE-like cells produce and secrete prostacyclin and tissue plasminogen activator at levels comparable to venous and aortic ECs. When compared to fibroblast cells, HE-like cells cultured on POC show a decrease in the rate of plasma and whole-blood clot formation as well as a decrease in platelet adhesion. Finally, the data show that HE-like cells can withstand physiological shear stress of 10 dynes/cm(2) when cultured on POC-modified expanded poly(tetrafluoroethylene) vascular grafts. Collectively, these data are the foundation for future clinical studies in the creation of an autologous endothelial cell-seeded vascular graft.
Collapse
|
19
|
Hashi CK, Derugin N, Janairo RRR, Lee R, Schultz D, Lotz J, Li S. Antithrombogenic modification of small-diameter microfibrous vascular grafts. Arterioscler Thromb Vasc Biol 2010; 30:1621-7. [PMID: 20466974 DOI: 10.1161/atvbaha.110.208348] [Citation(s) in RCA: 92] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVE To develop small-diameter vascular grafts with a microstructure similar to native matrix fibers and with chemically modified microfibers to prevent thrombosis. METHODS AND RESULTS Microfibrous vascular grafts (1-mm internal diameter) were fabricated by electrospinning, and hirudin was conjugated to the poly (L-lactic acid) microfibers through an intermediate linker of poly(ethylene glycol). The modified microfibrous vascular grafts were able to reduce platelet adhesion/aggregation onto microfibrous scaffolds, and immobilized hirudin suppressed thrombin activity that may interact with the scaffolds. This 2-pronged approach to modify microfibrous vascular graft showed significantly improved patency (from 50% to 83%) and facilitated endothelialization, and the microfibrous structure of the vascular grafts allowed efficient graft remodeling and integration, with the improvement of mechanical property (elastic modulus) from 3.5 to 11.1 MPa after 6 months of implantation. CONCLUSIONS Microfibrous vascular grafts with antithrombogenic microfibers can be used as small-diameter grafts, with excellent patency and remodeling capability.
Collapse
|
20
|
You Q, Wang F, Duan L, Du X, Xiao M, Shen Z. Construction of Small-Caliber, Polydiaxanone Cyclohexanone Vascular Stents. Cell Biochem Biophys 2010; 57:35-43. [DOI: 10.1007/s12013-010-9081-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
21
|
Abstract
Atherosclerosis in the form of peripheral arterial disease results in significant morbidity. Surgical treatment options for peripheral arterial disease include angioplasty, endarterectomy, and bypass grafting. For bypass grafting, vein remains the conduit of choice; however, poor quality and limited availability have led to the use of prosthetic materials. Unfortunately, because of a lack of endothelium and compliance mismatch, neointimal hyperplasia develops aggressively, resulting in high failure rates. To improve graft patency, investigators have developed surgical, chemical, and biological graft modifications. This review describes common prosthetic materials, as well as approaches currently in use and under investigation to modify and improve prosthetic conduits for bypass grafting in an effort to improve graft patency rates.
Collapse
Affiliation(s)
- Muneera R Kapadia
- Northwestern University Feinberg School of Medicine, Division of Vascular Surgery, Chicago, IL 60611, USA
| | | | | |
Collapse
|
22
|
Zilla P, Bezuidenhout D, Human P. Prosthetic vascular grafts: Wrong models, wrong questions and no healing. Biomaterials 2007; 28:5009-27. [PMID: 17688939 DOI: 10.1016/j.biomaterials.2007.07.017] [Citation(s) in RCA: 360] [Impact Index Per Article: 21.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2007] [Accepted: 07/06/2007] [Indexed: 12/20/2022]
Abstract
In humans, prosthetic vascular grafts remain largely without an endothelium, even after decades of implantation. While this shortcoming does not affect the clinical performance of large bore prostheses in aortic or iliac position, it contributes significantly to the high failure rate of small- to medium-sized grafts (SMGs). For decades intensive but largely futile research efforts have been under way to address this issue. In spite of the abundance of previous studies, a broad analysis of biological events dominating the incorporation of vascular grafts was hitherto lacking. By focusing on the three main contemporary graft types, expanded polytetrafluoroethylene (ePTFE), Dacron and Polyurethane (PU), accumulated clinical and experimental experience of almost half a century was available. The main outcome of this broad analysis-supported by our own experience in a senescent non-human primate model-was twofold: Firstly, inappropriate animal models, which addressed scientific questions that missed the point of clinical relevance, were largely used. This led to a situation where the vast majority of investigators unintentionally studied transanastomotic rather than transmural or blood-borne endothelialization. Given the fact that in patients transanastomotic endothelialization (TAE) covers only the immediate perianastomotic region of sometimes very long prostheses, TAE is rather irrelevant in the clinical context. Secondly, transmural endothelialization seems to have a time window of opportunity before a build-up of an adverse microenvironment. In selecting animal models that prematurely terminate this build-up through the early presence of an endothelium, the most significant 'impairment factor' for physiological tissue regeneration in vascular grafts remained ignored. By providing insight into mechanisms and experimental designs which obscured the purpose and scope of several decades of vascular graft studies, future research may better address clinical relevance.
Collapse
Affiliation(s)
- Peter Zilla
- Christian Barnard Department of Cardiothoracic Surgery/Cardiovascular Research Unit, University of Cape Town Medical School, Cape Town, South Africa.
| | | | | |
Collapse
|
23
|
|