1
|
Bagheri Hariri M, Siavash Moakhar R, Sharifi Abdar P, Zargarnezhad H, Shone M, Rahmani SA, Moradi N, Niksefat V, Shayar Bahadori K, Dolati A. Facile and ultra-sensitive voltammetric electrodetection of Hg 2+ in aqueous media using electrodeposited AuPtNPs/ITO. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:2688-2700. [PMID: 34036981 DOI: 10.1039/d1ay00361e] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
In this study, we have investigated the use of electrodeposited Au-Pt nanoparticles (AuPtNPs) on indium tin oxide (ITO) for the detection of Hg2+ heavy ions in water samples. The mechanism of AuPtNP electrocrystallization on ITO glass in an aqueous solution containing 0.5 mM HAuCl4 + 0.5 mM H2PtCl6 is described for the first time. The nucleation mechanism of monometallic AuNPs on ITO was found to be progressive; however, a transition from progressive to instantaneous was observed for bimetallic AuPtNPs at elevated overpotentials. The modified ITOs were then assessed for the electrodetection of Hg2+ in aqueous media. It was shown by differential pulse voltammetry (DPV) that the sensitivity of the constructed AuPtNPs/ITO electrode toward Hg2+ was about 2.08 μA nM-1. An approximate detection limit of 4.03 nM Hg2+ was achieved, which is below the permissible level of 30.00 nM Hg2+ in drinking water, according to the World Health Organization (WHO). Characterization of AuPt nanostructures was carried out by X-ray diffraction (XRD) patterns, scanning electron microscopy (SEM), and different electrochemical techniques (cyclic voltammetry (CV), chronoamperometry, and electrochemical impedance spectroscopy (EIS)). Our results indicate a good potential of a facile and robust electrochemical assembly for on-site detection of heavy metals in water samples.
Collapse
Affiliation(s)
- Mohiedin Bagheri Hariri
- Institute for Corrosion and Multiphase Technology, Department of Chemical and Biomolecular Engineering, Ohio University, Athens, Ohio 45701, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
2
|
Khumngern S, Choosang J, Thavarungkul P, Kanatharana P, Numnuam A. Flow injection enzyme-free amperometric uric acid sensor consisting of ordered mesoporous carbon decorated with 3D Pd-Pt alloy nanodendrite modified screen-printed carbon electrode. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104923] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
3
|
Zhang D, Ma J, Meng X, Xu Z, Zhang J, Fang Y, Guo Y. Electrochemical aptamer-based microsensor for real-time monitoring of adenosine in vivo. Anal Chim Acta 2019; 1076:55-63. [PMID: 31203964 DOI: 10.1016/j.aca.2019.05.035] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 05/07/2019] [Accepted: 05/14/2019] [Indexed: 11/24/2022]
Abstract
In this work, an implantable and minimally invasive micro-aptasensor for adenosine monitoring in vivo, based on flexible integrated electrodes, was developed. Firstly the sensor was made by the modification of a needle-type electrode with reduced graphene oxide and gold nanoclusters (rGO-AuNCs) using two-step electrodeposition. Secondly Sulfhydryl-terminated capture probe (ssDNA1) was immobilized on rGO-AuNCs modified electrode surface by self-assembly, and then it was hybridized with adenosine aptamer (ssDNA2). Lastly methylene blue (MB) as an electrochemical indicator was adsorbed on the aptamer through specific interaction of MB with guanine base. The peak current of MB decreased linearly with increasing adenosine concentration due to the formation of aptamer-adenosine complex and displacement of the aptamer from the modified electrode surface. The sensor showed a low detection limit of 0.1 nM with signal-to-noise ratio equal to 3 as well as a wide linear response range (0.1 nM-1 mM) in vitro. Also, a high selectivity was demonstrated for adenosine in relation to uridine, guanosine, and cytidine. Experiments in vivo demonstrated fast responses for a range of adenosine concentrations. This work demonstrates a promising path for implantable devices for the determination of biomolecules in vivo, thus allowing for health tests, detection of infectious diseases, and other medical conditions.
Collapse
Affiliation(s)
- Di Zhang
- Binhai Industrial Technology Research Institute of Zhejiang University, Tianjin, 300301, PR China
| | - Jiajia Ma
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China
| | - Xiangwen Meng
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China
| | - Zhifang Xu
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China
| | - Jian Zhang
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China
| | - Yuxin Fang
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China.
| | - Yi Guo
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China; College of Chinese Medical, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, PR China.
| |
Collapse
|
4
|
Huang X, Deng X, Zhu H, Qi W, Wu D. Ag@Fe2O3-graphene oxide nanocomposite as a novel redox probe for electrochemical immunosensor for alpha-fetoprotein detection. J Solid State Electrochem 2018. [DOI: 10.1007/s10008-018-4139-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
5
|
Zhang Y, Chu G, Guo Y, Zhao W, Yang Q, Sun X. An electrochemical biosensor based on Au nanoparticles decorated reduced graphene oxide for sensitively detecting of Hg2+. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.07.053] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
6
|
Recent advances in design of electrochemical affinity biosensors for low level detection of cancer protein biomarkers using nanomaterial-assisted signal enhancement strategies. J Pharm Biomed Anal 2018; 147:185-210. [DOI: 10.1016/j.jpba.2017.07.042] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2017] [Revised: 07/28/2017] [Accepted: 07/29/2017] [Indexed: 12/12/2022]
|
7
|
Ashassi-Sorkhabi H, Rezaei-Moghadam B, Asghari E, Bagheri R, Kabiri R. Sonoelectrosynthesized polypyrrole-graphene oxide nanocomposite modified by carbon nanotube and Cu2O nanoparticles on copper electrode for electrocatalytic oxidation of methanol. J Taiwan Inst Chem Eng 2016. [DOI: 10.1016/j.jtice.2016.08.026] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
8
|
Zhao Z, Gong R, Zheng L, Wang J. In Vivo Neural Recording and Electrochemical Performance of Microelectrode Arrays Modified by Rough-Surfaced AuPt Alloy Nanoparticles with Nanoporosity. SENSORS (BASEL, SWITZERLAND) 2016; 16:E1851. [PMID: 27827893 PMCID: PMC5134510 DOI: 10.3390/s16111851] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2016] [Revised: 10/18/2016] [Accepted: 10/28/2016] [Indexed: 11/16/2022]
Abstract
In order to reduce the impedance and improve in vivo neural recording performance of our developed Michigan type silicon electrodes, rough-surfaced AuPt alloy nanoparticles with nanoporosity were deposited on gold microelectrode sites through electro-co-deposition of Au-Pt-Cu alloy nanoparticles, followed by chemical dealloying Cu. The AuPt alloy nanoparticles modified gold microelectrode sites were characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and in vivo neural recording experiment. The SEM images showed that the prepared AuPt alloy nanoparticles exhibited cauliflower-like shapes and possessed very rough surfaces with many different sizes of pores. Average impedance of rough-surfaced AuPt alloy nanoparticles modified sites was 0.23 MΩ at 1 kHz, which was only 4.7% of that of bare gold microelectrode sites (4.9 MΩ), and corresponding in vitro background noise in the range of 1 Hz to 7500 Hz decreased to 7.5 μ V rms from 34.1 μ V rms at bare gold microelectrode sites. Spontaneous spike signal recording was used to evaluate in vivo neural recording performance of modified microelectrode sites, and results showed that rough-surfaced AuPt alloy nanoparticles modified microelectrode sites exhibited higher average spike signal-to-noise ratio (SNR) of 4.8 in lateral globus pallidus (GPe) due to lower background noise compared to control microelectrodes. Electro-co-deposition of Au-Pt-Cu alloy nanoparticles combined with chemical dealloying Cu was a convenient way for increasing the effective surface area of microelectrode sites, which could reduce electrode impedance and improve the quality of in vivo spike signal recording.
Collapse
Affiliation(s)
- Zongya Zhao
- Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Institute of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.
- National Engineering Research Center of Health Care and Medical Devices, Xi'an Jiaotong University Branch, Xi'an 710049, China.
| | - Ruxue Gong
- Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Institute of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.
- National Engineering Research Center of Health Care and Medical Devices, Xi'an Jiaotong University Branch, Xi'an 710049, China.
| | - Liang Zheng
- Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Institute of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.
- National Engineering Research Center of Health Care and Medical Devices, Xi'an Jiaotong University Branch, Xi'an 710049, China.
| | - Jue Wang
- Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Institute of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.
- National Engineering Research Center of Health Care and Medical Devices, Xi'an Jiaotong University Branch, Xi'an 710049, China.
| |
Collapse
|
9
|
Derikvand H, Roushani M, Abbasi AR, Derikvand Z, Azadbakht A. Design of folding-based impedimetric aptasensor for determination of the nonsteroidal anti-inflammatory drug. Anal Biochem 2016; 513:77-86. [DOI: 10.1016/j.ab.2016.06.013] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2016] [Revised: 06/07/2016] [Accepted: 06/08/2016] [Indexed: 11/24/2022]
|
10
|
Liu X, Liu P, Huo X, Liu X, Liu J. Preparation of TiO 2 nanosheet-carbon nanotube composite as immobilization platform for both primary and secondary antibodies in electrochemical immunoassay. Anal Chim Acta 2016; 946:40-47. [DOI: 10.1016/j.aca.2016.10.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2016] [Accepted: 10/16/2016] [Indexed: 11/29/2022]
|
11
|
Huang JY, Bao T, Hu TX, Wen W, Zhang XH, Wang SF. Voltammetric determination of levofloxacin using a glassy carbon electrode modified with poly(o-aminophenol) and graphene quantum dots. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1982-5] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
12
|
Derikvandi Z, Abbasi AR, Roushani M, Derikvand Z, Azadbakht A. Design of ultrasensitive bisphenol A-aptamer based on platinum nanoparticles loading to polyethyleneimine-functionalized carbon nanotubes. Anal Biochem 2016; 512:47-57. [PMID: 27307183 DOI: 10.1016/j.ab.2016.06.007] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2016] [Revised: 06/03/2016] [Accepted: 06/06/2016] [Indexed: 12/11/2022]
Abstract
Here, a highly sensitive electrochemical aptasensor based on a novel signal amplification strategy for the determination of bisphenol A (BPA) was developed. Construction of the aptasensor began with the deposition of highly dispersed platinum nanoparticles (PtNPs)/acid-oxidized carbon nanotubes (CNTs-COOH) functionalized with polyethyleneimine (PEI) at the surface of glassy carbon (PtNPs/PEI/CNTs-COOH/GC) electrode. After immobilizing the amine-capped capture probe (ssDNA1) through the covalent amide bonds formed by the carboxyl groups on the nanotubes and the amino groups on the oligonucleotides, we employed a designed complementary BPA-aptamer (ssDNA2) as a detection probe to hybridize with the ssDNA1. By adding BPA as a target, the aptamer specifically bound to BPA and its end folded into a BPA-binding junction. Because of steric/conformational restrictions caused by aptamer-BPA complex formation at the surface of modified electrode, the interfacial electron transfer of [Fe(CN)6](3-/4-) as a probe was blocked. Sensitive quantitative detection of BPA was carried out by monitoring the decrease of differential pulse voltammetric responses of [Fe(CN)6](3-/4-) peak current with increasing BPA concentrations. The newly developed aptasensor embraced a number of attractive features such as ease of fabrication, low detection limit, excellent selectivity, good stability and a wide linear range with respect to BPA.
Collapse
Affiliation(s)
- Zeinab Derikvandi
- Department of Chemistry, Khorramabad Branch, Islamic Azad University, Khorramabad, Iran
| | - Amir Reza Abbasi
- Department of Chemistry, Khorramabad Branch, Islamic Azad University, Khorramabad, Iran
| | | | - Zohreh Derikvand
- Department of Chemistry, Khorramabad Branch, Islamic Azad University, Khorramabad, Iran
| | - Azadeh Azadbakht
- Department of Chemistry, Khorramabad Branch, Islamic Azad University, Khorramabad, Iran.
| |
Collapse
|
13
|
Non-enzymatic detection of hydrogen peroxide based on Fenton-type reaction on poly(azure A)-chitosan/Cu modified electrode. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.09.063] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
14
|
Zhang Y, Zhang C, Zhang D, Ma M, Wang W, Chen Q. Nano-assemblies consisting of Pd/Pt nanodendrites and poly (diallyldimethylammonium chloride)-coated reduced graphene oxide on glassy carbon electrode for hydrogen peroxide sensors. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 58:1246-54. [PMID: 26478428 DOI: 10.1016/j.msec.2015.09.015] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2015] [Revised: 08/12/2015] [Accepted: 09/02/2015] [Indexed: 01/04/2023]
Abstract
Non-enzymatic hydrogen peroxide (H2O2) sensors were fabricated on the basis of glassy carbon (GC) electrode modified with palladium (Pd) core-platinum (Pt) nanodendrites (Pt-NDs) and poly (diallyldimethylammonium chloride) (PDDA)-coated reduced graphene oxide (rGO). A facile wet-chemical method was developed for preparing Pd core-Pt nanodendrites. In this approach, the growth of Pt NDs was directed by Pd nanocrystal which could be regarded as seed. The PDDA-coated rGO could form uniform film on the surface of GC electrode, which provided a support for Pd core- Pt NDs adsorption by self-assembly. The morphologies of the nanocomposites were characterized by transmission electron microscopy, energy-dispersive X-ray spectroscopy and X-ray diffraction (spectrum). Electrocatalytic ability of the nanocomposites was evaluated by cyclic voltammetry and chronoamperometric methods. The sensor fabricated by Pd core-Pt NDs/PDDA-rGO/GCE exhibited high sensitivity (672.753 μA mM(-1) cm(-2)), low detection limit (0.027 μM), wider linear range (0.005-0.5mM) and rapid response time (within 5s). Besides, it also exhibited superior reproducibility, excellent anti-interference performance and long-term stability. The present work could afford a viable method and efficient platform for fabricating all kinds of amperometric sensors and biosensors.
Collapse
Affiliation(s)
- Yanyan Zhang
- The Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Science, Nankai University, Weijin Road No. 94, Tianjin 300071, China
| | - Cong Zhang
- The Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Science, Nankai University, Weijin Road No. 94, Tianjin 300071, China
| | - Di Zhang
- The Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Science, Nankai University, Weijin Road No. 94, Tianjin 300071, China
| | - Min Ma
- The Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Science, Nankai University, Weijin Road No. 94, Tianjin 300071, China
| | - Weizhen Wang
- The Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Science, Nankai University, Weijin Road No. 94, Tianjin 300071, China
| | - Qiang Chen
- The Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Science, Nankai University, Weijin Road No. 94, Tianjin 300071, China.
| |
Collapse
|
15
|
Applications of electrochemical immunosensors for early clinical diagnostics. Talanta 2015; 132:162-74. [DOI: 10.1016/j.talanta.2014.08.063] [Citation(s) in RCA: 133] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2014] [Revised: 08/18/2014] [Accepted: 08/27/2014] [Indexed: 12/13/2022]
|
16
|
Hayat A, Catanante G, Marty JL. Current Trends in Nanomaterial-Based Amperometric Biosensors. SENSORS (BASEL, SWITZERLAND) 2014; 14:23439-23461. [PMID: 25494347 PMCID: PMC4299072 DOI: 10.3390/s141223439] [Citation(s) in RCA: 80] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2014] [Revised: 11/17/2014] [Accepted: 12/01/2014] [Indexed: 12/28/2022]
Abstract
The last decade has witnessed an intensive research effort in the field of electrochemical sensors, with a particular focus on the design of amperometric biosensors for diverse analytical applications. In this context, nanomaterial integration in the construction of amperometric biosensors may constitute one of the most exciting approaches. The attractive properties of nanomaterials have paved the way for the design of a wide variety of biosensors based on various electrochemical detection methods to enhance the analytical characteristics. However, most of these nanostructured materials are not explored in the design of amperometric biosensors. This review aims to provide insight into the diverse properties of nanomaterials that can be possibly explored in the construction of amperometric biosensors.
Collapse
Affiliation(s)
- Akhtar Hayat
- BIOMEM, Universitéde Perpignan, 52 Avenue Paul Alduy, 66860 Perpignan Cedex, France.
| | - Gaëlle Catanante
- BIOMEM, Universitéde Perpignan, 52 Avenue Paul Alduy, 66860 Perpignan Cedex, France.
| | - Jean Louis Marty
- BIOMEM, Universitéde Perpignan, 52 Avenue Paul Alduy, 66860 Perpignan Cedex, France.
| |
Collapse
|
17
|
Wang H, Li X, Mao K, Li Y, Du B, Zhang Y, Wei Q. Electrochemical immunosensor for α-fetoprotein detection using ferroferric oxide and horseradish peroxidase as signal amplification labels. Anal Biochem 2014; 465:121-6. [DOI: 10.1016/j.ab.2014.08.016] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2014] [Revised: 08/13/2014] [Accepted: 08/17/2014] [Indexed: 12/23/2022]
|
18
|
Kavosi B, Hallaj R, Teymourian H, Salimi A. Au nanoparticles/PAMAM dendrimer functionalized wired ethyleneamine–viologen as highly efficient interface for ultra-sensitive α-fetoprotein electrochemical immunosensor. Biosens Bioelectron 2014; 59:389-96. [DOI: 10.1016/j.bios.2014.03.049] [Citation(s) in RCA: 97] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2013] [Revised: 03/07/2014] [Accepted: 03/24/2014] [Indexed: 11/16/2022]
|
19
|
Asav E, Sezgintürk MK. A novel impedimetric disposable immunosensor for rapid detection of a potential cancer biomarker. Int J Biol Macromol 2014; 66:273-80. [DOI: 10.1016/j.ijbiomac.2014.02.032] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2013] [Revised: 02/11/2014] [Accepted: 02/13/2014] [Indexed: 12/16/2022]
|
20
|
Application of ZnO quantum dots dotted carbon nanotube for sensitive electrochemiluminescence immunoassay based on simply electrochemical reduced Pt/Au alloy and a disposable device. Anal Chim Acta 2014; 818:46-53. [DOI: 10.1016/j.aca.2014.01.047] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2013] [Revised: 12/17/2013] [Accepted: 01/22/2014] [Indexed: 12/11/2022]
|
21
|
Electrochemical immunosensor for alpha-fetoprotein determination based on ZnSe quantum dots/Azure I/gold nanoparticles/poly (3,4-ethylenedioxythiophene) modified Pt electrode. Electrochim Acta 2013. [DOI: 10.1016/j.electacta.2013.10.018] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
22
|
Ding L, Bond AM, Zhai J, Zhang J. Utilization of nanoparticle labels for signal amplification in ultrasensitive electrochemical affinity biosensors: A review. Anal Chim Acta 2013; 797:1-12. [DOI: 10.1016/j.aca.2013.07.035] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Revised: 07/08/2013] [Accepted: 07/14/2013] [Indexed: 12/11/2022]
|
23
|
Zhu Q, Yuan R, Chai Y, Han J, Li Y, Liao N. A novel amperometric immunosensor constructed with gold–platinum nanoparticles and horseradish peroxidase nanoparticles as well as nickel hexacyanoferrates nanoparticles. Analyst 2013; 138:620-6. [DOI: 10.1039/c2an36085c] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
24
|
Lai W, Tang D, Que X, Zhuang J, Fu L, Chen G. Enzyme-catalyzed silver deposition on irregular-shaped gold nanoparticles for electrochemical immunoassay of alpha-fetoprotein. Anal Chim Acta 2012; 755:62-8. [DOI: 10.1016/j.aca.2012.10.028] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2012] [Revised: 10/14/2012] [Accepted: 10/16/2012] [Indexed: 12/18/2022]
|
25
|
Fang Y, Zhang D, Qin X, Miao Z, Takahashi S, Anzai JI, Chen Q. A non-enzymatic hydrogen peroxide sensor based on poly(vinyl alcohol)–multiwalled carbon nanotubes–platinum nanoparticles hybrids modified glassy carbon electrode. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2012.03.105] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
26
|
Gao C, Guo Z, Liu JH, Huang XJ. The new age of carbon nanotubes: an updated review of functionalized carbon nanotubes in electrochemical sensors. NANOSCALE 2012; 4:1948-63. [PMID: 22337209 DOI: 10.1039/c2nr11757f] [Citation(s) in RCA: 168] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Since the discovery of carbon nanotubes (CNTs), they have drawn considerable research attention and have shown great potential application in many fields due to their unique structural, mechanical, and electronic properties. However, their native insolubility severely holds back the process of application. In order to overcome this disadvantage and broaden the scope of their application, chemical functionalization of CNTs has attracted great interest over the past several decades and produced various novel hybrid materials with specific applications. Notably, the rapid development of functionalized CNTs used as electrochemical sensors has been successfully witnessed. In this featured article, the recent progress of electrochemical sensors based on functionalized CNTs is discussed and classified according to modifiers covering organic (oxygen functional groups, small organic molecules, polymers, DNA, protein, etc.), inorganic (metal nanoparticles, metal oxide, etc.) and organic-inorganic hybrids. By employing some representative examples, it will be demonstrated that functionalized CNTs as templates, carriers, immobilizers and transducers are promising for the construction of electrochemical sensors.
Collapse
Affiliation(s)
- Chao Gao
- Research Center for Biomimetic Functional Materials and Sensing Devices, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, 230031, PR China
| | | | | | | |
Collapse
|
27
|
Hou S, Ou Z, Chen Q, Wu B. Amperometric acetylcholine biosensor based on self-assembly of gold nanoparticles and acetylcholinesterase on the sol–gel/multi-walled carbon nanotubes/choline oxidase composite-modified platinum electrode. Biosens Bioelectron 2012; 33:44-9. [DOI: 10.1016/j.bios.2011.12.014] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2011] [Revised: 12/07/2011] [Accepted: 12/08/2011] [Indexed: 11/27/2022]
|
28
|
Wei QH, Lei YF, Xu WR, Xie JM, Chen GN. Ru(ii) sensitized lanthanide luminescence: synthesis, photophysical properties, and near-infrared luminescent determination of alpha-fetal protein (AFP). Dalton Trans 2012; 41:11219-25. [DOI: 10.1039/c2dt30974b] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
29
|
Zhang B, Tang D, Liu B, Cui Y, Chen H, Chen G. Nanogold-functionalized magnetic beads with redox activity for sensitive electrochemical immunoassay of thyroid-stimulating hormone. Anal Chim Acta 2012; 711:17-23. [DOI: 10.1016/j.aca.2011.10.049] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2011] [Revised: 10/24/2011] [Accepted: 10/25/2011] [Indexed: 02/05/2023]
|
30
|
Chen W, Cai S, Ren QQ, Wen W, Zhao YD. Recent advances in electrochemical sensing for hydrogen peroxide: a review. Analyst 2011; 137:49-58. [PMID: 22081036 DOI: 10.1039/c1an15738h] [Citation(s) in RCA: 537] [Impact Index Per Article: 38.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Due to the significance of hydrogen peroxide (H(2)O(2)) in biological systems and its practical applications, the development of efficient electrochemical H(2)O(2) sensors holds a special attraction for researchers. Various materials such as Prussian blue (PB), heme proteins, carbon nanotubes (CNTs) and transition metals have been applied to the construction of H(2)O(2) sensors. In this article, the electrocatalytic H(2)O(2) determinations are mainly focused on because they can provide a superior sensing performance over non-electrocatalytic ones. The synergetic effect between nanotechnology and electrochemical H(2)O(2) determination is also highlighted in various aspects. In addition, some recent progress for in vivo H(2)O(2) measurements is also presented. Finally, the future prospects for more efficient H(2)O(2) sensing are discussed.
Collapse
Affiliation(s)
- Wei Chen
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, Hubei 430074, PR China
| | | | | | | | | |
Collapse
|