1
|
Ribeiro JA, Silva AF, Girault HH, Pereira CM. Electroanalytical applications of ITIES - A review. Talanta 2024; 280:126729. [PMID: 39180876 DOI: 10.1016/j.talanta.2024.126729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Revised: 08/14/2024] [Accepted: 08/16/2024] [Indexed: 08/27/2024]
Abstract
Over the last decades, the interface between two immiscible electrolyte solutions (ITIES) attracted considerable attention of the scientific community due to their vast applications, such as extraction, catalysis, partition studies and sensing. The aim of this Review is to highlight the potential of electrochemistry at the ITIES for analytical purposes, focusing on ITIES-based sensors for detection and quantification of chemically and biologically relevant (bio)molecules. We start by addressing the evolution of ITIES in terms of number of publications over the years along with an overview of their main applications (Chapter 1). Then, we provide a general historical perspective about pioneer voltammetric studies at water/oil systems (Chapter 2). After that, we discuss the most impacting improvements on ITIES sensing systems from both perspectives, set-up design (interface stabilization and miniaturization, selection of the organic solvent, etc.) and optimization of experimental conditions to improve selectivity and sensitivity (Chapter 3). In Chapter 4, we discuss the analytical applications of ITIES for electrochemical sensing of several types of analytes, including drugs, pesticides, proteins, among others. Finally, we highlight the present achievements of ITIES as analytical tool and provide future challenges and perspectives for this technology (Chapter 5).
Collapse
Affiliation(s)
- José A Ribeiro
- CIQUP/Institute of Molecular Sciences (IMS), Department of Chemistry and Biochemistry, Faculty of Sciences of University of Porto, Rua do Campo Alegre s/n, Porto, 4169-007, Portugal.
| | - A Fernando Silva
- CIQUP/Institute of Molecular Sciences (IMS), Department of Chemistry and Biochemistry, Faculty of Sciences of University of Porto, Rua do Campo Alegre s/n, Porto, 4169-007, Portugal
| | - H H Girault
- Institut des Sciences et Ingénierie Chimiques (ISIC), École Polytechnique Fédérale de Lausanne (EPFL), Station 6, CH-1015, Lausanne, Switzerland
| | - Carlos M Pereira
- CIQUP/Institute of Molecular Sciences (IMS), Department of Chemistry and Biochemistry, Faculty of Sciences of University of Porto, Rua do Campo Alegre s/n, Porto, 4169-007, Portugal.
| |
Collapse
|
2
|
Ion-transfer electrochemistry at arrays of nanoscale interfaces between two immiscible electrolyte solutions arranged in hexagonal format. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116113] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
3
|
Sreekanth SP, Alodhayb A, Assaifan AK, Alzahrani KE, Muthuramamoorthy M, Alkhammash HI, Pandiaraj S, Alswieleh AM, Van Le Q, Mangaiyarkarasi R, Grace AN, Raghavan V. Multi-walled carbon nanotube-based nanobiosensor for the detection of cadmium in water. ENVIRONMENTAL RESEARCH 2021; 197:111148. [PMID: 33878318 DOI: 10.1016/j.envres.2021.111148] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 03/14/2021] [Accepted: 03/30/2021] [Indexed: 06/12/2023]
Abstract
Industrial and agricultural processes have led to the prevalence of cadmium in the ecosystem. A successive build-up of cadmium in food and drinking water can result in inadvertent consumption of hazardous concentrations. Such environmental contamination of cadmium can pose a substantial threat to human and animal life. In humans, it is known to cause hypertension, cardiovascular diseases, DNA lesions, inhibition of DNA repair protein or disturb the functioning of lung, liver, prostate and kidney. The development of a reliable method for Cd (II) ions detection would reduce the exposure and complement existing conventional methods. In this study, a DNA based electrochemical method is employed for the detection of Cd (II) ions using ethyl green (EG) and multi-walled carbon nanotube (MWCNT). Glassy carbon electrode (GCE)/MWCNT forms the working electrode for differential pulse voltammetry (DPV) analysis for the detection of Cd (II) ions. The dsDNA is immobilized onto the working electrode. The indicator dye EG, preferably binds to ssDNA and its reduction peak current is noticeably less in the presence of dsDNA. The Cd (II) ions after interacting with dsDNA, unwinds the dsDNA to ssDNA, upon which the EG molecules bind to ssDNAs, giving a higher reduction peak current. The difference in the reduction peak currents in the presence and absence of Cd (II) ions is proportional to its concentration. The linear detection range achieved in this method is 2 nM-10.0 nM with a sensitivity of around 5 nA nM-1 and the limit of detection is 2 nM, which is less than the permissible limit of WHO for human exposure. This study considerably broadens the possible application of multi-walled carbon nanotube modified electrodes as biosensors and holds prospects for the detection of other heavy metals in environmental samples.
Collapse
Affiliation(s)
- S P Sreekanth
- Centre for Nanotechnology Research, Vellore Institute of Technology, Vellore, India
| | - Abdullah Alodhayb
- Research Chair for Tribology, Surface, and Interface Sciences, Department of Physics and Astronomy, College of Science, King Saud University, Riyadh, 11451, Saudi Arabia; King Abdullah Institute for Nanotechnology, King Saud University, P.O. Box 2455, Riyadh, 11451, Saudi Arabia
| | - Abdulaziz K Assaifan
- King Abdullah Institute for Nanotechnology, King Saud University, P.O. Box 2455, Riyadh, 11451, Saudi Arabia
| | - Khalid Eidah Alzahrani
- Research Chair for Tribology, Surface, and Interface Sciences, Department of Physics and Astronomy, College of Science, King Saud University, Riyadh, 11451, Saudi Arabia; King Abdullah Institute for Nanotechnology, King Saud University, P.O. Box 2455, Riyadh, 11451, Saudi Arabia
| | | | - Hend I Alkhammash
- Department of Electrical Engineering, College of Engineering, Taif University, P.O.Box 11099, Taif, 21944, Saudi Arabia
| | | | - Abdullah M Alswieleh
- Department of Chemistry, College of Science, King Saud University, Riyadh, Saudi Arabia
| | - Quyet Van Le
- Institute of Research and Development, Duy Tan University, Da Nang, 550000, Vietnam.
| | - R Mangaiyarkarasi
- Centre for Nanotechnology Research, Vellore Institute of Technology, Vellore, India
| | - Andrews Nirmala Grace
- Centre for Nanotechnology Research, Vellore Institute of Technology, Vellore, India.
| | - Vimala Raghavan
- Centre for Nanotechnology Research, Vellore Institute of Technology, Vellore, India.
| |
Collapse
|
4
|
Suárez-Herrera MF, Scanlon MD. Quantitative Analysis of Redox-Inactive Ions by AC Voltammetry at a Polarized Interface between Two Immiscible Electrolyte Solutions. Anal Chem 2020; 92:10521-10530. [PMID: 32608226 DOI: 10.1021/acs.analchem.0c01340] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The interface between two immiscible electrolyte solutions (ITIES) is ideally suited to detect redox-inactive ions by their ion transfer. Such electroanalysis, based on the Nernst-Donnan equation, has been predominantly performed using amperometry, cyclic voltammetry, or differential pulse voltammetry. Here, we introduce a new electroanalytical method based on alternating-current (AC) voltammetry with inherent advantages over traditional approaches such as avoidance of positive feedback iR compensation, a major issue for liquid|liquid electrochemical cells containing resistive organic media and interfacial areas in the cm2 and mm2 range. A theoretical background outlining the generation of the analytical signal is provided and based on extracting the component that depends on the Warburg impedance from the total impedance. The quantitative detection of a series of model redox-inactive tetraalkylammonium cations is demonstrated, with evidence provided of the transient adsorption of these cations at the interface during the course of ion transfer. Since ion transfer is diffusion-limited, by changing the voltage excitation frequency during AC voltammetry, the intensity of the Faradaic response can be enhanced at low frequencies (1 Hz) or made to disappear completely at higher frequencies (99 Hz). The latter produces an AC voltammogram equivalent to a "blank" measurement in the absence of analyte and is ideal for background subtraction. Therefore, major opportunities exist for the sensitive detection of ionic analyte when a "blank" measurement in the absence of analyte is impossible. This approach is particularly useful to deconvolute signals related to reversible electrochemical reactions from those due to irreversible processes, which do not give AC signals.
Collapse
Affiliation(s)
- Marco F Suárez-Herrera
- Departamento De Química, Facultad De Ciencias, Universidad Nacional De Colombia, Cra 30 # 45-03, Edificio 451, Bogotá, Colombia
| | - Micheál D Scanlon
- The Bernal Institute and Department of Chemical Sciences, School of Natural Sciences, University of Limerick (UL), Limerick V94 T9PX, Ireland
| |
Collapse
|
5
|
Wu J, Xu Z, Wang X, Wang L, Qiu H, Lu K, Zhang W, Feng Q, Chen J, Yang L. Cadmium-Sensitive Measurement Using a Nano-Copper-Enhanced Carbon Fiber Electrode. SENSORS (BASEL, SWITZERLAND) 2019; 19:E4901. [PMID: 31717598 PMCID: PMC6891438 DOI: 10.3390/s19224901] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Revised: 11/05/2019] [Accepted: 11/07/2019] [Indexed: 11/16/2022]
Abstract
Enrichment of cadmium ion (Cd2+) from the environment may lead to kidney disease and weakened immunity in the body. Current techniques are not convenient enough to measure Cd2+ concentration in the environment due to low sensitivity and poor linear range. In this paper, a new measurement technique is proposed using a new sensing electrode made of nano-copper-enhanced carbon fiber. Nano-copper was deposited onto the surface of carbon fiber to enhance the current concentration and mass transfer rate of Cd2+ during measurement, which improved the electrochemical detection sensitivity significantly (by up to 3.7 × 108 nA/nM) and broadened the linear range to 10~105 nM. This device provides a low-cost solution for measuring Cd2+ concentration in the environment.
Collapse
Affiliation(s)
- Jian Wu
- School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China; (J.W.); (H.Q.); (K.L.); (W.Z.)
| | - Zhipeng Xu
- Jinan Foreign Language School, Jinan 250014, China;
| | - Xian Wang
- Department of Mechanical & Industrial Engineering, University of Toronto, 5 King’s College Rd, Toronto, Ontario M5S 3G8, Canada;
| | - Li Wang
- School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China; (J.W.); (H.Q.); (K.L.); (W.Z.)
| | - Huadong Qiu
- School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China; (J.W.); (H.Q.); (K.L.); (W.Z.)
| | - Kechao Lu
- School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China; (J.W.); (H.Q.); (K.L.); (W.Z.)
| | - Wenhong Zhang
- School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China; (J.W.); (H.Q.); (K.L.); (W.Z.)
| | - Qing Feng
- School of Environmental Science & Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China;
| | - Jun Chen
- School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China; (J.W.); (H.Q.); (K.L.); (W.Z.)
| | - Lei Yang
- College of information science and engineering, Shandong Agricultural University, Tai’an 271018, China
| |
Collapse
|
6
|
Alvarez de Eulate E, Strutwolf J, Liu Y, O’Donnell K, Arrigan DWM. An Electrochemical Sensing Platform Based on Liquid–Liquid Microinterface Arrays Formed in Laser-Ablated Glass Membranes. Anal Chem 2016; 88:2596-604. [DOI: 10.1021/acs.analchem.5b03091] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Affiliation(s)
- Eva Alvarez de Eulate
- Nanochemistry
Research Institute, Department of Chemistry, Curtin University, GPO Box U1987, Perth, Western Australia 6845, Australia
| | - Jörg Strutwolf
- Department
of Chemistry, Institute of Organic Chemistry, University of Tübingen, 72074 Tübingen, Germany
| | - Yang Liu
- Nanochemistry
Research Institute, Department of Chemistry, Curtin University, GPO Box U1987, Perth, Western Australia 6845, Australia
| | - Kane O’Donnell
- Department
of Physics, Astronomy and Medical Radiation Science, Curtin University, GPO Box U1987, Perth, Western Australia 6845, Australia
| | - Damien W. M. Arrigan
- Nanochemistry
Research Institute, Department of Chemistry, Curtin University, GPO Box U1987, Perth, Western Australia 6845, Australia
| |
Collapse
|
7
|
Herzog G. Recent developments in electrochemistry at the interface between two immiscible electrolyte solutions for ion sensing. Analyst 2015; 140:3888-96. [DOI: 10.1039/c5an00601e] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The most recent developments on electrochemical sensing of ions at the liquid–liquid interface are reviewed here.
Collapse
Affiliation(s)
- Grégoire Herzog
- Laboratoire de Chimie Physique et Microbiologie pour l'Environnement (LCPME)
- UMR 7564
- CNRS – Université de Lorraine
- Villers-lès-Nancy
- France
| |
Collapse
|
8
|
M(II) transfer across a liquid-liquid microinterface facilitated by a complex formation with 8-Hydroxyquinoline: Application to quantification of Pb(II), Cd(II) and Zn(II) alone or in mixture in effluents. Electrochim Acta 2014. [DOI: 10.1016/j.electacta.2014.03.073] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|