1
|
Sahoo B, Sahoo PK, Rao Bhaviripudi V, Sahu KC, Tripathi A, Sahoo NK, Aepuru R, Gaikwad VM, Sahoo S, Satpati AK, Lee CP. Multifunctional Dy 2NiMnO 6/Reduced Graphene Oxide Nanocomposites and Their Catalytic, Electromagnetic Shielding, and Electrochemical Properties. ACS OMEGA 2024; 9:4600-4612. [PMID: 38313538 PMCID: PMC10832015 DOI: 10.1021/acsomega.3c07759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 12/25/2023] [Accepted: 12/29/2023] [Indexed: 02/06/2024]
Abstract
Multifunctional nanocomposites have shown great interest in clean energy systems and environmental applications in recent years. Herein, we first reported the synthesis of Dy2NiMnO6 (DNMO)/reduced graphene oxide (rGO) nanocomposites utilizing a hybrid approach involving sol-gel and solvothermal processes. Subsequently, we investigated these nanocomposites for their applications in catalysis, electromagnetic interference shielding, and supercapacitors. A morphological study suggests spherical-shaped DNMO nanoparticles of an average size of 382 nm that are uniformly distributed throughout the surface without any agglomeration. The as-prepared nanocomposites were used as catalysts to investigate the catalytic reduction of 4-nitrophenol in the presence of NaBH4. DNMO/rGO nanocomposites demonstrate superior catalytic activity when compared with bare DNMO, with the rate of reduction being influenced by the composition of the DNMO/rGO nanocomposites. In addition, novel multifunctional DNMO/rGO was incorporated into polyvinylidene difluoride (PVDF) to develop a flexible nanocomposite for electromagnetic shielding applications and exhibited a shielding effectiveness of 6 dB with 75% attenuation at a frequency of 8.5 GHz compared to bare PVDF and PVDF-DNMO nanocomposite. Furthermore, the electrochemical performance of DNMO/rGO nanocomposites was investigated as an electrode material for supercapacitors, exhibiting the highest specific capacitance of 260 F/g at 1 A/g. These findings provide valuable insights into the design of DNMO/rGO nanocomposites with remarkable performance in sustainable energy and environmental applications.
Collapse
Affiliation(s)
- Bibhuti
Bhusan Sahoo
- Department
of Mechanical Engineering, Siksha “O”
Anusandhan, Deemed to Be University, Bhubaneswar, Odisha 751030, India
| | - Prasanta Kumar Sahoo
- Department
of Mechanical Engineering, Siksha “O”
Anusandhan, Deemed to Be University, Bhubaneswar, Odisha 751030, India
- Environmental
Hydrology Division, National Institute of Hydrology, Jalvigyan Bhawan, Roorkee 247667, India
| | - Vijayabhaskara Rao Bhaviripudi
- Department
of Physics, Defence Institute of Advanced
Technology, Girinagar, Pune, Maharashtra 411025, India
- Departamento
de Ingeniería Química, Biotecnología y Materiales,
FCFM, Universidad de Chile, Santiago 8370415, Chile
| | - Krushna Chandra Sahu
- Department
of Chemistry, Siksha ‘O’ Anusandhan,
Deemed to be University, Bhubaneswar, Odisha 751030, India
| | - Abhishek Tripathi
- Department
of Metallurgical and Materials Engineering, Malaviya National Institute of Technology Jaipur, Jaipur 302017, India
| | - Naresh Kumar Sahoo
- Department
of Chemistry, Siksha ‘O’ Anusandhan,
Deemed to be University, Bhubaneswar, Odisha 751030, India
| | - Radhamanohar Aepuru
- Departamento
de Mecanica, Facultad de Ingeniería, Universidad Tecnológica Metropolitana, Santiago 7800002, Chile
| | - Vishwajit M. Gaikwad
- Department
of Physics, Amolakchand Mahavidyalaya, Yavatmal, Maharashtra 445001, India
| | - Srikant Sahoo
- Analytical
Chemistry Division, Bhabha Atomic Research
Centre, Trombay, Mumbai 400085, India
| | - Ashis Kumar Satpati
- Analytical
Chemistry Division, Bhabha Atomic Research
Centre, Trombay, Mumbai 400085, India
| | - Chuan-Pei Lee
- Department
of Applied Physics and Chemistry, University
of Taipei, Taipei 10048, Taiwan
| |
Collapse
|
2
|
Selvi SV, Krishnapandi A, Damastuti R, Prasannan A, Liang ST, Hong PD, Kim SC. Effectively Reinforced α-Bi 2O 3 MPs/PDA-RGO Sensor for Selective Modality Sensing of a Hazardous Phenolic Compound. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2023; 71:20563-20574. [PMID: 38109259 DOI: 10.1021/acs.jafc.3c03488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2023]
Abstract
The phenolic compound trichlorophenol (TCP) is an ingredient in fungicides and herbicides. This compound's high stability, bioaccumulation, toxicity, and poor biodegradability result in severe environmental and biological health issues. Consequently, it is crucial to have an affordable and sensitive method for detecting TCP in environmental samples. In this study, α-phase bismuth oxide microplates and polydopamine-functionalized reduced graphene oxide (α-Bi2O3 MPs/PDA-RGO) were synthesized using a simple ultrasonic method and characterized with various analytical and physical characterizations. The conversion of the catechol moieties present in the resulting PDA-RGO material into quinones facilitates productive interactions with diverse functional groups, such as hydroxyl, amine, and imine. Consequently, the compounds 2,4,6-trichlorophenol (TCP) engages in electrochemical interactions with the aforementioned functional groups. As a result, TCP shows more excellent selectivity on the designed α-Bi2O3 MPs/PDA-RGO/SPCE sensor. Under the optimized conditions, the sensor demonstrated a lower detection limit (0.0042 μM), a limit of quantification (0.0078 μM), good sensitivity (2.24 μA μM-1 cm2), a wide linear range (0.019-190.7 and 212.7-1649 μM), and pinpoint specificity. The efficacy of the sensor is additionally validated through the accurate identification of TCP residues in water, soil, and food samples.
Collapse
Affiliation(s)
- Subash Vetri Selvi
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 106335, Taiwan
| | | | - Retno Damastuti
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 106335, Taiwan
| | - Adhimoorthi Prasannan
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 106335, Taiwan
| | - Shu-Ting Liang
- Green Energy Nano Technology Co., Ltd., Taipei 104079, Taiwan
| | - Po-Da Hong
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 106335, Taiwan
| | - Seong-Cheol Kim
- School of Chemical Engineering, Yeungnam University, Gyeongsang 38541, Republic of Korea
| |
Collapse
|
3
|
Oubraham A, Ion-Ebrasu D, Vasut F, Soare A, Sorlei IS, Marinoiu A. Platinum-Functionalized Graphene Oxide: One-Pot Synthesis and Application as an Electrocatalyst. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1897. [PMID: 36903011 PMCID: PMC10004439 DOI: 10.3390/ma16051897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 02/21/2023] [Accepted: 02/22/2023] [Indexed: 06/18/2023]
Abstract
This paper presents the preparation of platinum on a reduced graphene oxide matrix (PtrGO) using the microwave-assisted method with three different pH solutions. The platinum concentration determined by energy-dispersive X-ray analysis (EDX) was 4.32 (weight%), 2.16 (weight %) and 5.70 (weight%), corresponding to pH 3.3, 11.7 and 7.2, respectively. Pt functionalization of reduced graphene oxide (rGO) decreased the rGO specific surface, as shown by Brunauer, Emmett and Teller (BET) analysis. An XRD spectrum of platinum-decorated reduced graphene oxide (rGO) showed the presence of the associated phases of rGO and centered cubic platinum peaks. An oxygen reduction reaction (ORR) electrochemical characterization performed using the rotating disk electrode (RDE) method showed that in PtGO1 synthetized in an acidic environment, with 4.32 Pt (weight%) determined by EDX, platinum is much more dispersed, which explains its better electrochemical oxygen reduction reaction performance. Koutecky-Levich (K-L) plots calculated at different potentials prove a good linear relationship. Electron transfer numbers (n) determined from the K-L plots are between 3.1 and 3.8, which confirms that the ORR for all the samples can be regarded as first-order reaction kinetics of O2 concentration formed on the Pt surface during ORR.
Collapse
|
4
|
Determination of Curcumin on Functionalized Carbon Nano Tube Modified Electrode and Probing its Interaction with DNA and Copper Ion. JOURNAL OF ANALYSIS AND TESTING 2022. [DOI: 10.1007/s41664-022-00242-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
5
|
Hu L, Cui J, Wang Y, Jia J. A highly sensitive electrochemical biosensor for Hg 2+ based on entropy-driven DNA walker-based amplification. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2504-2510. [PMID: 35703300 DOI: 10.1039/d2ay00619g] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Herein, a sensitive electrochemical biosensor based on an enzyme-free and entropy-driven DNA walker is presented for the determination of Hg2+. This biosensor uses Hg2+ as a key to induce a mismatch between thymine-rich oligonucleotides to start the DNA walker, and it utilizes the entropy change of the sensing system to continuously drive the hybridization of oligonucleotides as a driving force for its walking. As the DNA walker runs, the detection signal is amplified to improve the sensitivity of the biosensor. Square wave voltammetry (SWV) of this biosensor shows a linear response of the methylene blue (MB) oxidation signal with an increase of Hg2+ concentration in the range of 0 to 80 nM with a detection limit of 0.136 nM, which satisfactorily meets the sensitivity requirement of the U.S. Environmental Protection Agency (EPA). The biosensor also exhibits excellent selectivity over a spectrum of interfering ions and performs well in real water samples, suggesting that it is a promising candidate for Hg2+ detection.
Collapse
Affiliation(s)
- Liuyin Hu
- School of Environmental Science and Engineering, Shanghai Jiao Tong University, No. 800, Dongchuan Road, Shanghai 200240, P. R. China.
| | - Jiahua Cui
- School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, No. 800, Dongchuan Road, Shanghai 200240, P. R. China
| | - Yalin Wang
- School of Environmental Science and Engineering, Shanghai Jiao Tong University, No. 800, Dongchuan Road, Shanghai 200240, P. R. China.
| | - Jinping Jia
- School of Environmental Science and Engineering, Shanghai Jiao Tong University, No. 800, Dongchuan Road, Shanghai 200240, P. R. China.
- School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, No. 800, Dongchuan Road, Shanghai 200240, P. R. China
| |
Collapse
|
6
|
Bhattacharya S, Das AA, Chandra Dhal G, Sahoo PK, Tripathi A, Sahoo NK. Evaluation of N doped rGO-ZnO-CoPc(COOH) 8 nanocomposite in cyanide degradation and its bactericidal activities. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 302:114022. [PMID: 34735832 DOI: 10.1016/j.jenvman.2021.114022] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Revised: 09/25/2021] [Accepted: 10/25/2021] [Indexed: 06/13/2023]
Abstract
In the present study, an attempt has been made to design a solar light driven N-rGO-ZnO- CoPc(COOH)8 nanocomposite for the degradation of cyanide. The morphological and structural characterization of the synthesized nanocomposite was performed by XRD, FT-IR, XPS, UV-vis DRS, FESEM, TEM, EDS, PL spectra and BET surface area. The results revealed that almost 91% degradation and 86% toxicity removal occurred at 25 mgL-1 of initial cyanide concentration by the N-rGO-ZnO-CoPc(COOH)8 nanocomposite under illumination of solar light within 120 min. Analysis of free radicals reveals that the generation of OH. radicals was the predominant species in the photocatalytic degradation process. The cyanide degradation follows pseudo-first order kinetics. The estimated apparent rate constant (Kapp) of the above nanocomposite was 3 times higher than that of the ZnO photocatalyst alone together with a very good recycle activities. This might be due to the application of metallpthalocyanine photosensitizer CoPc(COOH)8 which enhances the rate of visible light absorption efficiency and activates the higher band gap ZnO photocatalyst under visible light. In addition, the presence of residual oxygen in N-rGO also promotes nucleation and anchor sites for interfacial contact between ZnO and N-rGO for effective charge transfer. Further, the N-rGO-ZnO-CoPc(COOH)8 photocatalytic system showed significant antibacterial activities against mixed culture systems. Therefore, the N-rGO-ZnO-CoPc(COOH)8 nanocomposite may be an alternative solar light driven photocatalyst system for the removal of cyanide from the wastewater along with its strong disinfectant activities.
Collapse
Affiliation(s)
- Shramana Bhattacharya
- Department of Chemistry, Environmental Science Program, Faculty of Engineering and Technology (ITER), Siksha'O'Anusandhan (Deemed to be University), Bhubaneswar, 751030, Odisha, India
| | - Anup Anang Das
- Department of Chemistry, Environmental Science Program, Faculty of Engineering and Technology (ITER), Siksha'O'Anusandhan (Deemed to be University), Bhubaneswar, 751030, Odisha, India
| | - Ganesh Chandra Dhal
- Department of Civil Engineering, National Institute of Technology, Meghalaya, India
| | - Prasanta Kumar Sahoo
- Department of Mechanical Engineering, Faculty of Engineering and Technology (ITER), Siksha'O'Anusandhan (Deemed to be University), Bhubaneswar, 751 030, Odisha, India
| | - Abhishek Tripathi
- Department of Metallurgical and Materials Engineering, Malaviya National Institute of Technology Jaipur, Jaipur, 302017, India
| | - Naresh Kumar Sahoo
- Department of Chemistry, Environmental Science Program, Faculty of Engineering and Technology (ITER), Siksha'O'Anusandhan (Deemed to be University), Bhubaneswar, 751030, Odisha, India.
| |
Collapse
|
7
|
Mohamad Nor N, Ramli NH, Poobalan H, Qi Tan K, Abdul Razak K. Recent Advancement in Disposable Electrode Modified with Nanomaterials for Electrochemical Heavy Metal Sensors. Crit Rev Anal Chem 2021; 53:253-288. [PMID: 34565248 DOI: 10.1080/10408347.2021.1950521] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Heavy metal pollution has gained global attention due to its high toxicity and non-biodegradability, even at a low level of exposure. Therefore, the development of a disposable electrode that is sensitive, simple, portable, rapid, and cost-effective as the sensor platform in electrochemical heavy metal detection is vital. Disposable electrodes have been modified with nanomaterials so that excellent electrochemical properties can be obtained. This review highlights the recent progress in the development of numerous types of disposable electrodes modified with nanomaterials for electrochemical heavy metal detection. The disposable electrodes made from carbon-based, glass-based, and paper-based electrodes are reviewed. In particular, the analytical performance, fabrication technique, and integration design of disposable electrodes modified with metal (such as gold, tin and bismuth), carbon (such as carbon nanotube and graphene), and metal oxide (such as iron oxide and zinc oxide) nanomaterials are summarized. In addition, the role of the nanomaterials in improving the electrochemical performance of the modified disposable electrodes is discussed. Finally, the current challenges and future prospect of the disposable electrode modified with nanomaterials are summarized.
Collapse
Affiliation(s)
- Noorhashimah Mohamad Nor
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Nurul Hidayah Ramli
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Hemalatha Poobalan
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Kai Qi Tan
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Khairunisak Abdul Razak
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia.,NanoBiotechnology Research & Innovation (NanoBRI), Institute for Research in Molecular Medicine, Universiti Sains Malaysia, 11800 USM, Pulau Pinang, Malaysia
| |
Collapse
|
8
|
Esmaeili M, Ahour F, Keshipour S. Sensitive and selective determination of trace amounts of mercury ions using a dimercaprol functionalized graphene quantum dot modified glassy carbon electrode. NANOSCALE 2021; 13:11403-11413. [PMID: 34160516 DOI: 10.1039/d1nr00076d] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
A novel nanomaterial is synthesized based on the functionalization of graphene quantum dot with dimercaprol (GQD-DMC). Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and high-resolution transmission electron microscopy (TEM) are used to approve the successful synthesis of GQD-DMC. The synthesized nanomaterial is used as an electrode modifier for the sensitive and selective determination of mercury(ii) ions in real water samples. The method of evaluation is based on the pre-concentration of mercury ions on the GQD-DMC modified glassy carbon electrode, reduction of Hg(ii), and anodic stripping voltammetric measurement of these reduced ions in a buffer solution. The pre-concentration of mercury ions is driven by the affinity interaction between the surface containing functional groups of DMC and Hg(ii) ions. The GQD-DMC modified glassy carbon electrode (GQD-DMC/GCE) shows extra sensitivity and selectivity for mercury(ii) detection, which is assumed to be due to the increased surface area as well as the presence of sulfur-containing functional groups on the modified structure.
Collapse
Affiliation(s)
- M Esmaeili
- Nanotechnology Research Center, Faculty of Science, Urmia University, Urmia, Iran.
| | - F Ahour
- Nanotechnology Research Center, Faculty of Science, Urmia University, Urmia, Iran.
| | - S Keshipour
- Nanotechnology Research Center, Faculty of Science, Urmia University, Urmia, Iran.
| |
Collapse
|
9
|
Kasturi S, Eom Y, Torati SR, Kim C. Highly sensitive electrochemical biosensor based on naturally reduced rGO/Au nanocomposite for the detection of miRNA-122 biomarker. J IND ENG CHEM 2021. [DOI: 10.1016/j.jiec.2020.09.022] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
10
|
Kong D, Yao J, Li X, Luo J, Yang M. A reusable AuNPS with increased stability applied for fast screening of trace heavy metals in edible and medicinal marine products. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2020; 204:111107. [PMID: 32823057 DOI: 10.1016/j.ecoenv.2020.111107] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 07/29/2020] [Accepted: 07/30/2020] [Indexed: 06/11/2023]
Abstract
Heavy metal pollution in marine environment poses a severe threat to the safety of marine products and is thus causing increasingly concerns in terms of their toxicity and potential health risks pose to human. Due to the complex matrix of marine products, a fast screening method for heavy metals at trace level with low price, reusability, high accuracy and long lifetime is of urgency and necessity for consumers and processing factories. This work described a simplified screening system through the preparation, characterization and particular application of Au nano particle sensor (AuNPS) in the complex marine matrix, the main aim is to significantly increase the stability, sensitivity and lifetime of detection system dedicated to Cu and Hg trace analysis in marine products. It is worth mentioning that, the proposed screening system was characterized through electrochemical experiments and theoretical calculations, which could be a new evidence for selecting the detection system in commercially complex samples. Importantly, the discipline of deposition and oxidative stripping process on AuNPS was explained based on the mechanism of Metal Ion Deficient Layer (MIDL), and illustrated with SEM changes during stripping process, as well as the dissolving-out rate of metals on AuNPS material. Moreover, to further improve the reusability and stability of AuNPS sensor, the complex marine matrix was purified by pre-plating interferences on indium tin oxide glass electrode. The screening system exhibited a liner response in the range of 0.02-0.10 μg mL-1 for Hg, 0.01-0.10 μg mL-1 and 0.001-0.01 μg mL-1 for Cu with the detection limits of 0.138 mg kg-1 and 1.51 mg kg-1 in marine matrix, respectively. The sensitivity and lifetime was at least two times better as compared to similar works even after 20-times use. Finally, this proposed analysis system combined with purification procedure was successfully applied for the edible and medicinal marine products analysis, meanwhile, the accuracy and stability were confirmed with standard analytical methods.
Collapse
Affiliation(s)
- Dandan Kong
- Key Laboratory of Bioactive Substances and Resources Utilization of Chinese Herbal Medicine, Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100193, PR China
| | - Jiaojiao Yao
- Key Laboratory of Bioactive Substances and Resources Utilization of Chinese Herbal Medicine, Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100193, PR China
| | - Xinyue Li
- Key Laboratory of Bioactive Substances and Resources Utilization of Chinese Herbal Medicine, Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100193, PR China
| | - Jiaoyang Luo
- Key Laboratory of Bioactive Substances and Resources Utilization of Chinese Herbal Medicine, Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100193, PR China
| | - Meihua Yang
- Key Laboratory of Bioactive Substances and Resources Utilization of Chinese Herbal Medicine, Ministry of Education, Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100193, PR China.
| |
Collapse
|
11
|
A novel low cost nonenzymatic hydrogen peroxide sensor based on CoFe2O4/CNTs nanocomposite modified electrode. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114504] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
12
|
Sangili A, Kalyani T, Chen SM, Nanda A, Jana SK. Label-Free Electrochemical Immunosensor Based on One-Step Electrochemical Deposition of AuNP-RGO Nanocomposites for Detection of Endometriosis Marker CA 125. ACS APPLIED BIO MATERIALS 2020; 3:7620-7630. [DOI: 10.1021/acsabm.0c00821] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Arumugam Sangili
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan, ROC
- Department of Biotechnology, National Institute of Technology, Papum Pare 791112, Arunachal Pradesh, India
| | - Thangapandi Kalyani
- Department of Biotechnology, National Institute of Technology, Papum Pare 791112, Arunachal Pradesh, India
| | - Shen-Ming Chen
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan, ROC
| | - Amalesh Nanda
- Department of Biotechnology, National Institute of Technology, Papum Pare 791112, Arunachal Pradesh, India
| | - Saikat Kumar Jana
- Department of Biotechnology, National Institute of Technology, Papum Pare 791112, Arunachal Pradesh, India
| |
Collapse
|
13
|
Li L, Qiu Y, Feng Y, Li Y, Wu K, Zhu L. Stripping voltammetric analysis of mercury ions at nitrogen-doped reduced graphene oxide modified electrode. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114121] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
14
|
Chauhan S, Sahoo S, Satpati AK, Sharma C, Sahoo PK. Prussian Blue Nanocubes‐SnO
2
Quantum Dots‐Reduced Graphene Oxide Ternary Nanocomposite: An Efficient Non‐noble‐metal Electrocatalyst for Non‐enzymatic Detection of H
2
O
2. ELECTROANAL 2020. [DOI: 10.1002/elan.202000041] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Seema Chauhan
- Department of Paper TechnologyIndian Institute of Technology Roorkee, Saharanpur Campus Saharanpur 247001 India
| | - Srikant Sahoo
- Analytical Chemistry DivisionBhabha Atomic Research Centre, Trombay Mumbai 400085 India
| | - Ashis Kumar Satpati
- Analytical Chemistry DivisionBhabha Atomic Research Centre, Trombay Mumbai 400085 India
| | - Chhaya Sharma
- Department of Paper TechnologyIndian Institute of Technology Roorkee, Saharanpur Campus Saharanpur 247001 India
| | - Prasanta Kumar Sahoo
- Department of Mechanical Engineering, Siksha ‘O' AnusandhanDeemed to be University Bhubaneswar 751030 India
| |
Collapse
|
15
|
Britto Hurtado R, Cortez-Valadez M, Aragon-Guajardo J, Cruz-Rivera J, Martínez-Suárez F, Flores-Acosta M. One-step synthesis of reduced graphene oxide/gold nanoparticles under ambient conditions. ARAB J CHEM 2020. [DOI: 10.1016/j.arabjc.2017.12.021] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
|
16
|
Ipte PR, Kumar S, Satpati AK. Electrochemical synthesis of carbon nano spheres and its application for detection of ciprofloxacin. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART A, TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING 2019; 55:142-150. [PMID: 31594467 DOI: 10.1080/10934529.2019.1674591] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 09/26/2019] [Accepted: 09/26/2019] [Indexed: 06/10/2023]
Abstract
Carbon nano spheres (CNSs) were synthesized by single step electrochemical synthesis route in ultra-pure water as a medium of synthesis. Characterization of synthesized CNSs was carried out using atomic force microscope (AFM), particle size analyzer, zeta potential analyzer and Fourier Transform Infrared (FTIR) measurements, from which the information about the morphology and functional groups present on the surface of the particles are obtained. The particle size of the CNSs was found to be 6 nm. FTIR spectrum shows the presence of functional groups such as -OH, C≡C, C = C and on the CNSs. Electrochemical and spectroscopic experiments were conducted to determine the interaction of the drug molecule ciprofloxacin (Cf) with CNSs, strong interaction between Cf and CNSs leads to the development of analytical method of detection of Cf using CNSs as the pre-concentrating agent. The detection of limit of the present method is obtained as 0.15 μM at (S/N) ratio of 3. CNSs can be considered as a potential candidate for the fabrication of sensor for high sensitive determination of Cf.
Collapse
Affiliation(s)
- Priyanka R Ipte
- Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai, Maharashtra, India
| | - Sriram Kumar
- Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai, Maharashtra, India
| | | |
Collapse
|
17
|
Zuo Y, Xu J, Zhu X, Duan X, Lu L, Yu Y. Graphene-derived nanomaterials as recognition elements for electrochemical determination of heavy metal ions: a review. Mikrochim Acta 2019; 186:171. [PMID: 30756239 DOI: 10.1007/s00604-019-3248-5] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2018] [Accepted: 01/05/2019] [Indexed: 10/27/2022]
Abstract
This review (with 155 refs.) summarizes the progress made in the past few years in the field of electrochemical sensors based on graphene-derived materials for the determination of heavy metal ions. Following an introduction of this field and a discussion of the various kinds of modified graphenes including graphene oxide and reduced graphene oxide, the review covers graphene based electrodes modified (or doped) with (a) heteroatoms, (b) metal nanoparticles, (c) metal oxides, (d) small organic molecules, (e) polymers, and (f) ternary nanocomposites. Tables are provided that afford an overview of representative methods and materials for fabricating electrochemical sensors. Furthermore, sensing mechanisms are discussed. A concluding section presents new perspectives, opportunities and current challenges. Graphical Abstract Schematic illustration of electrochemical sensor for heavy metal ion sensing based on heteroatom-doped graphene, metal-modified graphene, metal-oxide-modified graphene, organically modified graphene, polymer-modified graphene, and ternary graphene based nanocomposites.
Collapse
Affiliation(s)
- Yinxiu Zuo
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang, 330013, Jiangxi, China.,Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Institute of Functional Materials and Agricultural Applied Chemistry, College of Science, Jiangxi Agricultural University, Nanchang, Nanchang, 330045, China
| | - Jingkun Xu
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang, 330013, Jiangxi, China.,School of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, Shandong, China
| | - Xiaofei Zhu
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang, 330013, Jiangxi, China
| | - Xuemin Duan
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang, 330013, Jiangxi, China.
| | - Limin Lu
- Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Institute of Functional Materials and Agricultural Applied Chemistry, College of Science, Jiangxi Agricultural University, Nanchang, Nanchang, 330045, China.
| | - Yongfang Yu
- Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Institute of Functional Materials and Agricultural Applied Chemistry, College of Science, Jiangxi Agricultural University, Nanchang, Nanchang, 330045, China
| |
Collapse
|
18
|
Teodoro KBR, Migliorini FL, Facure MHM, Correa DS. Conductive electrospun nanofibers containing cellulose nanowhiskers and reduced graphene oxide for the electrochemical detection of mercury(II). Carbohydr Polym 2018; 207:747-754. [PMID: 30600061 DOI: 10.1016/j.carbpol.2018.12.022] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2018] [Revised: 11/02/2018] [Accepted: 12/10/2018] [Indexed: 10/27/2022]
Abstract
Mercury is a heavy metal highly deleterious for the environment being associated to several diseases. Thus, novel and expedite techniques capable of detecting this heavy metal in water, even at trace levels, are highly sought for human and environmental safety purposes. Here we developed a novel electrochemical sensor for detecting mercury(II) using a green hybrid nanoarchitecture composed of reduced graphene oxide (rGO), cellulose nanowhiskers (CNW) and polyamide 6 (PA6) electrospun nanofibers. Scanning transmission electron microscopy (STEM), ultraviolet-visible (UV-VIS) absorption and Fourier transform infrared (FTIR) spectroscopies and termogravimetric analysis (TGA) were employed to elucidate the morphology and composition of CNW:rGO hybrid system. The hybrid composite proved to enhance charge transference properties, which was evaluated by cyclic voltammetry (CV) experiments. Due to the excellent electrical properties of graphene, the nanocomposite (PA6/CNW:rGO) was applied in the electrochemical detection of very low concentrations of mercury in water samples, improving the sensor sensibility. Moreover, the PA6/CNW/rGO electrode demonstrated stability, high selectivity, low detection limit and wide dynamic linear range for the detection of mercury(II).
Collapse
Affiliation(s)
- Kelcilene B R Teodoro
- Nanotechnology National Laboratory for Agriculture (LNNA), Embrapa Instrumentação, 13560-970, São Carlos, SP, Brazil; PPGQ, Department of Chemistry, Center for Exact Sciences and Technology, Federal University of São Carlos (UFSCar), 13565-905, São Carlos, SP, Brazil
| | - Fernanda L Migliorini
- Nanotechnology National Laboratory for Agriculture (LNNA), Embrapa Instrumentação, 13560-970, São Carlos, SP, Brazil
| | - Murilo H M Facure
- Nanotechnology National Laboratory for Agriculture (LNNA), Embrapa Instrumentação, 13560-970, São Carlos, SP, Brazil; PPGQ, Department of Chemistry, Center for Exact Sciences and Technology, Federal University of São Carlos (UFSCar), 13565-905, São Carlos, SP, Brazil
| | - Daniel S Correa
- Nanotechnology National Laboratory for Agriculture (LNNA), Embrapa Instrumentação, 13560-970, São Carlos, SP, Brazil; PPGQ, Department of Chemistry, Center for Exact Sciences and Technology, Federal University of São Carlos (UFSCar), 13565-905, São Carlos, SP, Brazil.
| |
Collapse
|
19
|
Tamiji T, Nezamzadeh-Ejhieh A. A comprehensive study on the kinetic aspects and experimental design for the voltammetric response of a Sn(IV)-clinoptilolite carbon paste electrode towards Hg(II). J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.10.011] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
20
|
Guan P, Guo PR, Liu N, Zhang F, Lei YQ. The preparation of a flexible AuNP modified carbon cloth electrode and its application in electrochemical detection of Hg(ii) by continuous flow in environmental water. Analyst 2018; 143:4436-4441. [PMID: 30151540 DOI: 10.1039/c8an01284a] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In this article, a carbon cloth composite electrode modified with gold nanoparticles (AuNPs) was prepared by a facile in situ electrodeposition method and applied to the detection of mercury ions in water. With the optimized electrochemical detection conditions and methods, the limit of detection (LOD) was 0.6 μg L-1 with the linearity ranging from 2 to 200 μg L-1 by the SWSV detection method, and the electrode showed good repeatability after many cycles. Based on this detection method, a continuous flow electrochemical detection system was constructed and applied to the detection of Hg ions in environmental water samples. The standard addition experimental results of two real water samples with an addition level of 10 and 50 μg L-1 showed that the recoveries were between 92.4% and 108.9% with RSDs from 2.01% to 3.22%. These results showed the same performance as that of the ZAAS mercury detection method (recovery: 94-102.4%, RSD 2.09-5.4%). Compared with other electrode materials, a shorter detection time, a wider linear range and high stability with a similar LOD can be achieved by a continuous flow detection method by using the composite electrode. The established continuous flow electrochemical detection system would have promising application in online and real-time detection of heavy metals in environmental water.
Collapse
Affiliation(s)
- Peng Guan
- Guangdong Provincial Key laboratory of Emergency Test for Dangerous Chemicals, Guangdong Engineering Technology Research Center of On-line Monitoring of Water Environmental Pollution, Guangdong Institute of Analysis, Guangzhou, 510070, China. and College of Petrochemical Technology, Lanzhou University of Technology, Lanzhou, 730050, China
| | - Peng-Ran Guo
- Guangdong Provincial Key laboratory of Emergency Test for Dangerous Chemicals, Guangdong Engineering Technology Research Center of On-line Monitoring of Water Environmental Pollution, Guangdong Institute of Analysis, Guangzhou, 510070, China.
| | - Ning Liu
- Guangdong Provincial Key laboratory of Emergency Test for Dangerous Chemicals, Guangdong Engineering Technology Research Center of On-line Monitoring of Water Environmental Pollution, Guangdong Institute of Analysis, Guangzhou, 510070, China.
| | - Fang Zhang
- Guangdong Provincial Key laboratory of Emergency Test for Dangerous Chemicals, Guangdong Engineering Technology Research Center of On-line Monitoring of Water Environmental Pollution, Guangdong Institute of Analysis, Guangzhou, 510070, China.
| | - Yong-Qian Lei
- Guangdong Provincial Key laboratory of Emergency Test for Dangerous Chemicals, Guangdong Engineering Technology Research Center of On-line Monitoring of Water Environmental Pollution, Guangdong Institute of Analysis, Guangzhou, 510070, China.
| |
Collapse
|
21
|
Li J, Ji Q, Lai B, Yuan D. Degradation of p -nitrophenol by Fe 0 /H 2 O 2 /persulfate system: Optimization, performance and mechanisms. J Taiwan Inst Chem Eng 2017. [DOI: 10.1016/j.jtice.2017.09.002] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
22
|
Suherman AL, Tanner EE, Compton RG. Recent developments in inorganic Hg 2+ detection by voltammetry. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.07.020] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
23
|
Arulraj AD, Devasenathipathy R, Chen SM, Vasantha VS, Wang SF. Femtomolar detection of mercuric ions using polypyrrole, pectin and graphene nanocomposites modified electrode. J Colloid Interface Sci 2016; 483:268-274. [DOI: 10.1016/j.jcis.2016.08.026] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2016] [Revised: 08/08/2016] [Accepted: 08/10/2016] [Indexed: 02/01/2023]
|
24
|
Graphene-based materials for the electrochemical determination of hazardous ions. Anal Chim Acta 2016; 946:9-39. [DOI: 10.1016/j.aca.2016.10.019] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2016] [Revised: 10/11/2016] [Accepted: 10/15/2016] [Indexed: 01/07/2023]
|
25
|
Puangjan A, Chaiyasith S. An efficient ZrO2/Co3O4/reduced graphene oxide nanocomposite electrochemical sensor for simultaneous determination of gallic acid, caffeic acid and protocatechuic acid natural antioxidants. Electrochim Acta 2016. [DOI: 10.1016/j.electacta.2016.04.185] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
26
|
Shams N, Lim HN, Hajian R, Yusof NA, Abdullah J, Sulaiman Y, Ibrahim I, Huang NM. Electrochemical sensor based on gold nanoparticles/ethylenediamine-reduced graphene oxide for trace determination of fenitrothion in water. RSC Adv 2016. [DOI: 10.1039/c6ra13384c] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
AuNP/en-rGO/SPE electrochemical sensor for sensitive determination of fenitrothion in natural waters.
Collapse
Affiliation(s)
- Nafiseh Shams
- Institute of Advanced Technology
- Universiti Putra Malaysia
- Selangor
- Malaysia
| | - Hong Ngee Lim
- Institute of Advanced Technology
- Universiti Putra Malaysia
- Selangor
- Malaysia
- Department of Chemistry
| | - Reza Hajian
- Institute of Advanced Technology
- Universiti Putra Malaysia
- Selangor
- Malaysia
| | - Nor Azah Yusof
- Institute of Advanced Technology
- Universiti Putra Malaysia
- Selangor
- Malaysia
- Department of Chemistry
| | - Jaafar Abdullah
- Institute of Advanced Technology
- Universiti Putra Malaysia
- Selangor
- Malaysia
- Department of Chemistry
| | - Yusran Sulaiman
- Institute of Advanced Technology
- Universiti Putra Malaysia
- Selangor
- Malaysia
- Department of Chemistry
| | - Izwaharyanie Ibrahim
- Department of Chemistry
- Faculty of Science
- Universiti Putra Malaysia
- Selangor
- Malaysia
| | - Nay Ming Huang
- Centre of Printable Electronics
- Deputy Vice Chancellor Office (Research & Innovation)
- University of Malaya
- 50603 Kuala Lumpur
- Malaysia
| |
Collapse
|