1
|
Almeida JMS, Pedro ZSB, Buoro RM, Brett CMA. Binary and Ternary Deep Eutectic Solvents for Methylene Green Electropolymerization on Multiwalled Carbon Nanotubes: Optimization, Characterization and Application. Chemistry 2024; 30:e202401752. [PMID: 38900538 DOI: 10.1002/chem.202401752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 06/14/2024] [Accepted: 06/20/2024] [Indexed: 06/21/2024]
Abstract
Choline chloride (ChCl) based binary and ternary deep eutectic solvents (DES) were evaluated for methylene green electropolymerization with oxalic acid (OA) and ethylene glycol (EG) as hydrogen bond donors. Binary DES ChCl : OA in molar ratios 1 : 1 and 2 : 1 and ChCl : EG 1 : 2 and ternary DES (tDES) in different molar ratios and percentages of water were evaluated. The highest polymer growth was in ChCl : OA : EG-tDES with 13% added water, that had a lower viscosity and higher ionic conductivity when associated with HCl as dopant. This enhanced the formation of more cation radicals and, consequently, more polymer formation. The PMG/MWCNT/GCE-tDES sensor was successfully applied to the simultaneous determination of 5-aminosalicylic acid (5-ASA) and acetaminophen (APAP) by differential pulse voltammetry in the concentration range 1 μM-200 μM, with detection limits of 0.37 μM and 0.49 μM for 5-ASA and APAP, respectively. The sensor demonstrated good repeatability, reproducibility and stability, and was successfully applied in pharmaceutical formulations.
Collapse
Affiliation(s)
- Joseany M S Almeida
- Department of Chemistry, CEMMPRE, ARISE, Faculty of Sciences and Technology, University of Coimbra, 3004-535, Coimbra, Portugal
| | - Zeferino S B Pedro
- Department of Chemistry, CEMMPRE, ARISE, Faculty of Sciences and Technology, University of Coimbra, 3004-535, Coimbra, Portugal
| | - Rafael M Buoro
- Department of Chemistry and Molecular Physics, São Carlos Chemistry Institute, University of São Paulo, 13566-590, São Carlos, Brazil
| | - Christopher M A Brett
- Department of Chemistry, CEMMPRE, ARISE, Faculty of Sciences and Technology, University of Coimbra, 3004-535, Coimbra, Portugal
| |
Collapse
|
2
|
da Silva W, Guedes EAB, Faustino LC, Goulart MOF, Gerôncio ETS. Tailored electrochemical biosensor with poly-diallydimethylammonium chloride-functionalised multiwalled carbon nanotubes/gold nanoparticles/manganese dioxide, and haemoglobin for sensitive hydrogen peroxide detection. Talanta 2024; 276:126290. [PMID: 38805755 DOI: 10.1016/j.talanta.2024.126290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 04/28/2024] [Accepted: 05/18/2024] [Indexed: 05/30/2024]
Abstract
A very sensitive electrochemical biosensor, with haemoglobin (Hb) as its basis, has been created to quantify hydrogen peroxide (H2O2), an essential marker in environmental monitoring, food safety, and medical diagnosis. The sensor uses a simple, eco-friendly preparation method. Hb was immobilised on manganese dioxide nanostructure/gold nanoparticles/poly-diallydimethylammonium chloride-functionalised multiwalled carbon nanotubes (PDDA-MWCNT/AuNP/MnO2), characterised using various techniques: amperometry, voltammetry, X-ray diffraction (XRD), and transmission electron microscopy (TEM). Nafion was used as a binder membrane to preserve the biological and electrochemical properties of the protein on the modified electrode. In comparison to earlier research, the novel biosensor had a lower detection limit (1.83 μM) and a limit of quantification (6.11 μM) (S/N = 3) for H2O2. It also exhibited notable reproducibility, long-term stability, and repeatability. It was effectively used to measure the amount of H2O2 in cow milk and orange juice, yielding recoveries in the order of 98.90-99.53 % with RSDs less than 5.0 %, which makes it a promising biosensor for food control.
Collapse
Affiliation(s)
- Wanderson da Silva
- Instituto de Química e Biotecnologia, Universidade Federal de Alagoas, Maceió, Alagoas, 57072-970, Brazil; Departamento de Química, Centro de Ciências da Natureza, Universidade Federal do Piauí, Teresina, 64049-550, Piauí, Brazil.
| | - Erik A B Guedes
- Instituto de Química e Biotecnologia, Universidade Federal de Alagoas, Maceió, Alagoas, 57072-970, Brazil.
| | - Lucas C Faustino
- Departamento de Química, Centro de Ciências da Natureza, Universidade Federal do Piauí, Teresina, 64049-550, Piauí, Brazil.
| | - Marília O F Goulart
- Instituto de Química e Biotecnologia, Universidade Federal de Alagoas, Maceió, Alagoas, 57072-970, Brazil.
| | - Everson Thiago S Gerôncio
- Departamento de Química, Centro de Ciências da Natureza, Universidade Federal do Piauí, Teresina, 64049-550, Piauí, Brazil.
| |
Collapse
|
3
|
Svigelj R, Toniolo R, Bertoni C, Fraleoni-Morgera A. Synergistic Applications of Graphene-Based Materials and Deep Eutectic Solvents in Sustainable Sensing: A Comprehensive Review. SENSORS (BASEL, SWITZERLAND) 2024; 24:2403. [PMID: 38676019 PMCID: PMC11054382 DOI: 10.3390/s24082403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 03/19/2024] [Accepted: 04/04/2024] [Indexed: 04/28/2024]
Abstract
The recently explored synergistic combination of graphene-based materials and deep eutectic solvents (DESs) is opening novel and effective avenues for developing sensing devices with optimized features. In more detail, remarkable potential in terms of simplicity, sustainability, and cost-effectiveness of this combination have been demonstrated for sensors, resulting in the creation of hybrid devices with enhanced signal-to-noise ratios, linearities, and selectivity. Therefore, this review aims to provide a comprehensive overview of the currently available scientific literature discussing investigations and applications of sensors that integrate graphene-based materials and deep eutectic solvents, with an outlook for the most promising developments of this approach.
Collapse
Affiliation(s)
- Rossella Svigelj
- Department of Agrifood, Environmental and Animal Sciences, University of Udine, 33100 Udine, Italy
| | - Rosanna Toniolo
- Department of Agrifood, Environmental and Animal Sciences, University of Udine, 33100 Udine, Italy
| | | | | |
Collapse
|
4
|
Yılmaz M, Bilgi M. A disposable impedimetric immunosensor for the analysis of CA125 in human serum samples. Biomed Microdevices 2024; 26:8. [PMID: 38180587 DOI: 10.1007/s10544-023-00691-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/06/2023] [Indexed: 01/06/2024]
Abstract
Cancer antigen 125 (CA125) is the most common biomarker used to diagnose and monitor ovarian cancer progression for the last four decades, and precise detection of its levels in blood serum is crucial. In this work, label-free impedimetric CA125 immunosensors were fabricated by using screen-printed carbon electrodes modified with poly toluidine blue (PTB) (in deep eutectic solvent)/gold nanoparticles (AuNP) for the sensitive, environmentally friendly, economical, and practical analysis of CA125. The materials of PTBDES and AuNP were characterized by Fourier Transform Infrared (FT-IR), Scanning Electron Microscope (FE-SEM), and X-ray Diffraction (XRD). The analysis of the CA125 was performed by electrochemical impedance spectroscopy and the developed immunosensor. The immunosensor's repeatability, reproducibility, reusability, selectivity, and storage stability were examined. The developed label-free immunosensor allowed the determination of CA125 in fast, good repeatability and a low limit of detection (1.20 pg mL-1) in the linear range of 5-100 pg mL-1. The stable surface of the fabricated immunosensor was successfully regenerated ten times. The application of immunosensors in commercial human blood serum was performed, and good recoveries were achieved. The disposable label-free impedimetric CA125 immunosensor developed for the rapid and practical detection of CA125 is a candidate for use in point-of-care tests in clinical applications of ovarian cancer.
Collapse
Affiliation(s)
- Merve Yılmaz
- Faculty of Science, Chemistry Department, Çankırı Karatekin University, Çankırı, 18100, Türkiye
| | - Melike Bilgi
- Faculty of Science, Chemistry Department, Çankırı Karatekin University, Çankırı, 18100, Türkiye.
| |
Collapse
|
5
|
Porfireva A, Begisheva E, Evtugyn V, Evtugyn G. Electrochemical DNA Sensor for Valrubicin Detection Based on Poly(Azure C) Films Deposited from Deep Eutectic Solvent. BIOSENSORS 2023; 13:931. [PMID: 37887124 PMCID: PMC10605098 DOI: 10.3390/bios13100931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 09/29/2023] [Accepted: 10/16/2023] [Indexed: 10/28/2023]
Abstract
A novel electrochemical DNA sensor was developed for the detection of the anthracycline drug, valrubicin, on the base of poly(Azure C) electropolymerized from the deep eutectic solvent reline and covered with adsorbed DNA from calf thymus. Biosensor assembling was performed by multiple scanning of the potential in one drop (100 µL) of the dye dissolved in reline and placed on the surface of a screen-printed carbon electrode. Stabilization of the coating was achieved by its polarization in the phosphate buffer. The electrochemical characteristics of the electron transfer were determined and compared with a similar coating obtained from phosphate buffer. The use of deep eutectic solvent made it possible to increase the monomer concentration and avoid using organic solvents on the stage of electrode modification. After the contact of the DNA sensor with valrubicin, two signals related to the intrinsic redox activity of the coating and the drug redox conversion were found on voltammogram. Their synchronous changes with the analyte concentration increased the reliability of the detection. In the square-wave mode, the DNA sensor made it possible to determine from 3 µM to 1 mM (limit of detection, 1 µM) in optimal conditions. The DNA sensor was successfully tested in the voltammetric determination of valrubicin in spiked artificial urine, Ringer-Locke solution mimicking plasma electrolytes and biological samples (urine and saliva) with a recovery of 90-110%. After further testing on clinical samples, it can find application in the pharmacokinetics studies and screening of new drugs' interaction with DNA.
Collapse
Affiliation(s)
- Anna Porfireva
- A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia; (E.B.); (G.E.)
| | - Ekaterina Begisheva
- A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia; (E.B.); (G.E.)
| | - Vladimir Evtugyn
- Interdisciplinary Center of Analytical Microscopy, Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia;
| | - Gennady Evtugyn
- A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia; (E.B.); (G.E.)
- Analytical Chemistry Department, Chemical Technology Institute, Ural Federal University, 19 Mira Street, 620002 Ekaterinburg, Russia
| |
Collapse
|
6
|
Nam NN, Do HDK, Trinh KTL, Lee NY. Design Strategy and Application of Deep Eutectic Solvents for Green Synthesis of Nanomaterials. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:1164. [PMID: 37049256 PMCID: PMC10096871 DOI: 10.3390/nano13071164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/12/2023] [Accepted: 03/16/2023] [Indexed: 06/19/2023]
Abstract
The first report of deep eutectic solvents (DESs) was released in 2003 and was identified as a new member of ionic liquid (IL), involving innovative chemical and physical characteristics. Using green solvent technology concerning economical, practical, and environmental aspects, DESs open the window for sustainable development of nanomaterial fabrication. The DESs assist in different fabrication processes and design nanostructures with specific morphology and properties by tunable reaction conditions. Using DESs in synthesis reactions can reduce the required high temperature and pressure conditions for decreasing energy consumption and the risk of environmental contamination. This review paper provides the recent applications and advances in the design strategy of DESs for the green synthesis of nanomaterials. The strategy and application of DESs in wet-chemical processes, nanosize reticular material fabrication, electrodeposition/electrochemical synthesis of nanostructures, electroless deposition, DESs based nano-catalytic and nanofluidic systems are discussed and highlighted in this review.
Collapse
Affiliation(s)
- Nguyen Nhat Nam
- Biotechnology Center, School of Agriculture and Aquaculture, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Hoang Dang Khoa Do
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ward 13, District 04, Ho Chi Minh City 700000, Vietnam
| | - Kieu The Loan Trinh
- Department of BioNano Technology, Gachon University, 1342 Seongnam-Daero, Sujeong-Gu, Seongnam-Si 13120, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-Daero, Sujeong-Gu, Seongnam-Si 13120, Republic of Korea
| |
Collapse
|
7
|
El Fazdoune M, Bahend K, Ben Jadi S, Oubella M, García-García FJ, Bazzaoui EA, Asserghine A, Bazzaoui M. Different electrochemical techniques for the electrosynthesis of poly methylene blue in sodium saccharin aqueous medium. J Solid State Electrochem 2022. [DOI: 10.1007/s10008-022-05362-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
8
|
Comment on “Electrochemical Characterisation of Polymelamine Electropolymerised in Deep Eutectic Solvents for Selective Detection of Dopamine”. Electrocatalysis (N Y) 2022. [DOI: 10.1007/s12678-022-00785-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
9
|
Du M, Li T, Zhu W, Shi Y, Chen X, Wang C, Fan J. In-situ formation of hydrophobic deep eutectic solvent for the enrichment and quantitative determination of triclosan in personal care products and environmental water samples. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
10
|
Abad-Gil L, Brett CM. Poly(methylene blue)-ternary deep eutectic solvent/Au nanoparticle modified electrodes as novel electrochemical sensors: optimization, characterization and application. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.141295] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
11
|
Ding M, Niu H, Zhang N, Hou T, Guan P, Hu X. Facile fabrication of electrochemically reduced graphene oxide/polythionine-methylene blue and its use as a platform for detection of nicotinamide adenine dinucleotide in the artificial urine sample. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140715] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
12
|
Mnasri A, Dhaouadi H, Khiari R, Halila S, Mauret E. Effects of Deep Eutectic Solvents on cellulosic fibres and paper properties: Green “chemical” refining. Carbohydr Polym 2022; 292:119606. [DOI: 10.1016/j.carbpol.2022.119606] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 04/24/2022] [Accepted: 05/07/2022] [Indexed: 11/02/2022]
|
13
|
Ivanov A, Stoikov D, Shafigullina I, Shurpik D, Stoikov I, Evtugyn G. Flow-Through Acetylcholinesterase Sensor with Replaceable Enzyme Reactor. BIOSENSORS 2022; 12:bios12090676. [PMID: 36140061 PMCID: PMC9496324 DOI: 10.3390/bios12090676] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 08/18/2022] [Accepted: 08/21/2022] [Indexed: 11/16/2022]
Abstract
Fast and reliable determination of enzyme inhibitors are of great importance in environmental monitoring and biomedicine because of the high biological activity and toxicity of such species and the necessity of their reliable assessment in many media. In this work, a flow-through biosensor has been developed and produced by 3D printing from poly(lactic acid). Acetylcholinesterase from an electric eel was immobilized on the inner walls of the reactor cell. The concentration of thiocholine formed in enzymatic hydrolysis of the substrate was monitored amperometrically with a screen-printed carbon electrode modified with carbon black particles, pillar[5]arene, electropolymerized Methylene blue and thionine. In the presence of thiocholine, the cathodic current at −0.25 V decreased because of an alternative chemical reaction of the macrocycle. The conditions of enzyme immobilization and signal measurements were optimized and the performance of the biosensor was assessed in the determination of reversible (donepezil, berberine) and irreversible (carbofuran) inhibitors. In the optimal conditions, the flow-through biosensor made it possible to determine 1.0 nM–1.0 μM donepezil, 1.0 μM–1.0 mM berberine and 10 nM to 0.1 μM carbofuran. The AChE biosensor was tested on spiked samples of artificial urine for drugs and peanuts for carbofuran. Possible interference of the sample components was eliminated by dilution of the samples with phosphate buffer. Easy mounting, low cost of replaceable parts of the cell and satisfactory analytical and metrological characteristics made the biosensor a promising future application as a point-of-care or point-of-demand device outside of a chemical laboratory.
Collapse
Affiliation(s)
- Alexey Ivanov
- A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
- Correspondence: ; Tel.: +7-(843)-233-74-91
| | - Dmitry Stoikov
- A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
| | - Insiya Shafigullina
- A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
| | - Dmitry Shurpik
- A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
| | - Ivan Stoikov
- A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
| | - Gennady Evtugyn
- A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
- Analytical Chemistry Department, Chemical Technology Institute, Ural Federal University, 19 Mira Street, 620002 Ekaterinburg, Russia
| |
Collapse
|
14
|
Dalkiran B, Brett CM. Poly(safranine T)-deep eutectic solvent/copper oxide nanoparticle-carbon nanotube nanocomposite modified electrode and its application to the simultaneous determination of hydroquinone and catechol. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107531] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
15
|
Augusto KKDL, Piton GR, Gomes-Júnior PC, Longatto GP, de Moraes FC, Fatibello-Filho O. Enhancing the electrochemical sensitivity of hydroquinone using a hydrophobic deep eutectic solvent-based carbon paste electrode. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2003-2013. [PMID: 35543344 DOI: 10.1039/d2ay00473a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The present study reports the synthesis and characterization of hydrophobic deep eutectic solvents (HDES) based on fatty acids and tetrabutylammonium bromide (TBAB) or 1-octanol using Fourier transform infrared spectroscopy, and the analysis of the physicochemical properties (viscosity, density, electrical conductivity, and water content) of these solvents. A carbon paste electrode modified with 6.0% (m/m) decanoic acid and TBAB-based HDES was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy. The oxidation peak currents of the proposed electrode were enhanced by its high electrochemical activity, fast electron transfer rate, and high surface area, while a remarkable decrease was observed in the peak potential separation. The electrochemical determination of hydroquinone (H2Q) was carried out using square-wave adsorptive anodic stripping voltammetry (SWAdASV). The electrode response was found to be linear in the H2Q concentration range of 2.5 × 10-6-3.0 × 10-3 mol L-1, with the limit of detection (LOD) of 7.7 × 10-7 mol L-1. The method was successfully applied for H2Q determination in dermatological creams.
Collapse
Affiliation(s)
- Karen Kenlderi de Lima Augusto
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235, P. O. Box 676, São Carlos, SP, 13560-970, Brazil.
| | - Gabriela Rizzo Piton
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235, P. O. Box 676, São Carlos, SP, 13560-970, Brazil.
| | - Paulo Cardoso Gomes-Júnior
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235, P. O. Box 676, São Carlos, SP, 13560-970, Brazil.
| | - Gustavo Patelli Longatto
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235, P. O. Box 676, São Carlos, SP, 13560-970, Brazil.
| | - Fernando Cruz de Moraes
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235, P. O. Box 676, São Carlos, SP, 13560-970, Brazil.
| | - Orlando Fatibello-Filho
- Department of Chemistry, Federal University of São Carlos, Rod. Washington Luís km 235, P. O. Box 676, São Carlos, SP, 13560-970, Brazil.
| |
Collapse
|
16
|
Leote RJB, Ghica ME, Brett CMA. Pyruvate Oxidase Biosensors Based on Glassy Carbon Electrodes Modified with Carbon Nanotubes and Poly(Neutral Red) Synthesized in Ethaline Deep Eutectic Solvent. ELECTROANAL 2022. [DOI: 10.1002/elan.202100164] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Ricardo J. B. Leote
- University of Coimbra CEMMPRE Department of Chemistry 3004-535 Coimbra Portugal
- National Institute of Materials Physics Atomistilor Str. 405 A 077125 Magurele Romania
| | - Mariana E. Ghica
- University of Coimbra CEMMPRE Department of Chemistry 3004-535 Coimbra Portugal
- University of Coimbra CIEPQPF Department of Chemical Engineering 3030-790 Coimbra Portugal
| | | |
Collapse
|
17
|
da Silva W, Brett CM. Electrosynthesis and characterisation of novel poly(Nile blue)-deep eutectic solvent/Prussian blue nanoparticle modified electrodes and their biosensing application. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
18
|
Abad-Gil L, Procopio JR, Brett CM. Binary and ternary deep eutectic solvent mixtures: Influence on methylene blue electropolymerisation. Electrochem commun 2021. [DOI: 10.1016/j.elecom.2021.106967] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
|
19
|
Electrochemical Characterization of Melamine Electropolymerized in Deep Eutectic Solvents for Selective Detection of Dopamine. Electrocatalysis (N Y) 2021. [DOI: 10.1007/s12678-021-00648-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
20
|
Hybrid Nanocomposite Platform, Based on Carbon Nanotubes and Poly(Methylene Blue) Redox Polymer Synthesized in Ethaline Deep Eutectic Solvent for Electrochemical Determination of 5-Aminosalicylic Acid. SENSORS 2021; 21:s21041161. [PMID: 33562228 PMCID: PMC7915580 DOI: 10.3390/s21041161] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 02/04/2021] [Accepted: 02/04/2021] [Indexed: 11/17/2022]
Abstract
A novel hybrid composite of conductive poly(methylene blue) (PMB) and carbon nanotubes (CNT) was prepared for the detection of 5-aminosalicylic acid (5-ASA). Electrosynthesis of PMB with glassy carbon electrode (GCE) or with carbon nanotube modified GCE was done in ethaline deep eutectic solvent of choline chloride mixed with ethylene glycol and a 10% v/v aqueous solution. Different sensor architectures were evaluated in a broad range of pH values in a Britton-Robinson (BR) buffer using electrochemical techniques, chronoamperometry (CA), and differential pulse voltammetry (DPV), to determine the optimum sensor configuration for 5-ASA sensing. Under optimal conditions, the best analytical performance was obtained with CNT/PMBDES/GCE in 0.04 M BR buffer pH 7.0 in the range 5-100 µM 5-ASA using the DPV method, with an excellent sensitivity of 9.84 μA cm-2 μM-1 (4.9 % RSD, n = 5) and a detection limit (LOD) (3σ/slope) of 7.7 nM, outclassing most similar sensors found in the literature. The sensitivity of the same sensor obtained in CA (1.33 μA cm-2 μM-1) under optimal conditions (pH 7.0, Eapp = +0.40 V) was lower than that obtained by DPV. Simultaneous detection of 5-ASA and its analogue, acetaminophen (APAP), was successfully realized, showing a catalytic effect towards the electro-oxidation of both analytes, lowering their oxidation overpotential, and enhancing the oxidation peak currents and peak-to-peak separation as compared with the unmodified electrode. The proposed method is simple, sensitive, easy to apply, and economical for routine analysis.
Collapse
|
21
|
Characterization of complicated electropolymerization using UV–vis spectroelectrochemistry and an electrochemical quartz-crystal microbalance with dissipation: A case study of tricarbazole derivatives. Electrochem commun 2021. [DOI: 10.1016/j.elecom.2020.106913] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
22
|
Nahar Y, Thickett SC. Greener, Faster, Stronger: The Benefits of Deep Eutectic Solvents in Polymer and Materials Science. Polymers (Basel) 2021; 13:447. [PMID: 33573280 PMCID: PMC7866798 DOI: 10.3390/polym13030447] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 01/25/2021] [Accepted: 01/26/2021] [Indexed: 11/17/2022] Open
Abstract
Deep eutectic solvents (DESs) represent an emergent class of green designer solvents that find numerous applications in different aspects of chemical synthesis. A particularly appealing aspect of DES systems is their simplicity of preparation, combined with inexpensive, readily available starting materials to yield solvents with appealing properties (negligible volatility, non-flammability and high solvation capacity). In the context of polymer science, DES systems not only offer an appealing route towards replacing hazardous volatile organic solvents (VOCs), but can serve multiple roles including those of solvent, monomer and templating agent-so called "polymerizable eutectics." In this review, we look at DES systems and polymerizable eutectics and their application in polymer materials synthesis, including various mechanisms of polymer formation, hydrogel design, porous monoliths, and molecularly imprinted polymers. We provide a comparative study of these systems alongside traditional synthetic approaches, highlighting not only the benefit of replacing VOCs from the perspective of environmental sustainability, but also the materials advantage with respect to mechanical and thermal properties of the polymers formed.
Collapse
Affiliation(s)
| | - Stuart C. Thickett
- School of Natural Sciences—Chemistry, University of Tasmania, Hobart, TAS 7001, Australia;
| |
Collapse
|
23
|
Ghoorchian A, Madrakian T, Afkhami A, Bagheri H. Spectroelectrochemical and electrochromic behavior of poly(methylene blue) and poly(thionine)-modified multi-walled carbon nanotubes. J Solid State Electrochem 2021. [DOI: 10.1007/s10008-021-04901-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
24
|
De Alvarenga G, Hryniewicz BM, Jasper I, Silva RJ, Klobukoski V, Costa FS, Cervantes TN, Amaral CD, Schneider JT, Bach-Toledo L, Peralta-Zamora P, Valerio TL, Soares F, Silva BJ, Vidotti M. Recent trends of micro and nanostructured conducting polymers in health and environmental applications. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114754] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
25
|
Dalkıran B, Fernandes IPG, David M, Brett CMA. Electrochemical synthesis and characterization of poly(thionine)-deep eutectic solvent/carbon nanotube-modified electrodes and application to electrochemical sensing. Mikrochim Acta 2020; 187:609. [PMID: 33057990 DOI: 10.1007/s00604-020-04588-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 10/01/2020] [Indexed: 01/09/2023]
Abstract
Electropolymerization of thionine (TH) on multiwalled carbon nanotube (MWCNT)-modified glassy carbon electrodes (GCE) in ethaline deep eutectic solvent (DES) was carried out for the first time, to prepare poly(thionine) (PTH) films with different nanostructured morphologies. PTH films were formed on MWCNT/GCE by potential cycling electropolymerization in ethaline with the addition of different acid dopants CH3COOH, HClO4, HNO3, H2SO4 and HCl, acetic acid being the best. The electropolymerization process was monitored with an electrochemical quartz crystal microbalance. The polymerization scan rate was a key factor affecting the electrochemical and morphological properties of the PTHEthaline-CH3COOH/MWCNT/GCE; electrodeposition at 200 mV s-1 showing the best performance. The PTH/MWCNT/GCE platform was characterized using cyclic and differential pulse voltammetry, electrochemical impedance spectroscopy and scanning electron microscopy. The analytical characteristics of the PTH films were evaluated for sensing of ascorbic acid and biosensing of uric acid. The developed sensor exhibited a low detection limit (1.1 μM), wide linear range (2.8-3010 μM) and high sensitivity (1134 μA cm-2 mM-1) for ascorbic acid. After immobilization of uricase, UOx, on PTH/MWCNT/GCE, the biosensor was successfully applied to the determination of uric acid, with fast response (˂ 7 s), good sensitivity (450 μA cm-2 mM-1, wide linear range (0.48-279 μM) and low detection limit (58.9 nM), better than in the literature and than with PTH prepared in aqueous solution. The determination of uric acid in synthetic urine samples was successfully tested and the mean analytical recovery was 100.8 ± 1.4%. This is a promising approach for the determination of uric acid in real samples. Graphical abstract.
Collapse
Affiliation(s)
- Berna Dalkıran
- CEMMPRE, Department of Chemistry, University of Coimbra, 3004-535, Coimbra, Portugal
| | - Isabel P G Fernandes
- CEMMPRE, Department of Chemistry, University of Coimbra, 3004-535, Coimbra, Portugal
| | - Melinda David
- CEMMPRE, Department of Chemistry, University of Coimbra, 3004-535, Coimbra, Portugal
| | - Christopher M A Brett
- CEMMPRE, Department of Chemistry, University of Coimbra, 3004-535, Coimbra, Portugal.
| |
Collapse
|
26
|
Shishov A, Pochivalov A, Nugbienyo L, Andruch V, Bulatov A. Deep eutectic solvents are not only effective extractants. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115956] [Citation(s) in RCA: 73] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
27
|
da Silva W, Queiroz AC, Brett CM. Nanostructured Poly(Phenazine)/Fe2O3 nanoparticle film modified electrodes formed by electropolymerization in ethaline - Deep eutectic solvent. Microscopic and electrochemical characterization. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.136284] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
28
|
Dhingra D, Bhawna, Pandey A, Pandey S. Fluorescence Quenching by Nitro Compounds within a Hydrophobic Deep Eutectic Solvent. J Phys Chem B 2020; 124:4164-4173. [DOI: 10.1021/acs.jpcb.0c02231] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Divya Dhingra
- Department of Chemistry, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | - Bhawna
- Department of Chemistry, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | - Ashish Pandey
- Department of Chemistry, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | - Siddharth Pandey
- Department of Chemistry, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| |
Collapse
|
29
|
Babaei H, Khosravi M, Sovizi MR, Khorramie SA. Investigating the Au-Cu thick layers Electrodeposition Rate with Pulsed Current by Optimization of the Operation Condition. J ELECTROCHEM SCI TE 2020. [DOI: 10.33961/jecst.2019.00087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
30
|
Bhawna B, Dhingra D, Pandey A, Pandey S. Norharmane prototropism in choline chloride-based deep eutectic solvents. J Photochem Photobiol A Chem 2020. [DOI: 10.1016/j.jphotochem.2019.112138] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
31
|
Jablonský M, Škulcová A, Šima J. Use of Deep Eutectic Solvents in Polymer Chemistry-A Review. Molecules 2019; 24:E3978. [PMID: 31684174 PMCID: PMC6864848 DOI: 10.3390/molecules24213978] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 10/30/2019] [Accepted: 11/01/2019] [Indexed: 12/18/2022] Open
Abstract
This review deals with two overlapping issues, namely polymer chemistry and deep eutectic solvents (DESs). With regard to polymers, specific aspects of synthetic polymers, polymerization processes producing such polymers, and natural cellulose-based nanopolymers are evaluated. As for DESs, their compliance with green chemistry requirements, their basic properties and involvement in polymer chemistry are discussed. In addition to reviewing the state-of-the-art for selected kinds of polymers, the paper reveals further possibilities in the employment of DESs in polymer chemistry. As an example, the significance of DES polarity and polymer polarity to control polymerization processes, modify polymer properties, and synthesize polymers with a specific structure and behavior, is emphasized.
Collapse
Affiliation(s)
- Michal Jablonský
- Institute of Natural and Synthetic Polymers, Department of Wood, Pulp and Paper, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinskeho 9, Bratislava SK-812 37, Slovakia.
| | - Andrea Škulcová
- Department of Zoology and Fisheries, Faculty of Agrobiology, Food and Natural Resources, Czech University of Life Science, Kamýcka 129, 165 00 Prague 6-Suchdol, Czech Republic.
- Institute of Chemical and Environmental Engineering, Department of Environmental Engineering, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinskeho 9, Bratislava SK-812 37, Slovakia.
| | - Jozef Šima
- Department of Inorganic Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinskeho 9, Bratislava SK-812 37, Slovakia.
| |
Collapse
|
32
|
Biotoxic trace metal ion detection by enzymatic inhibition of a glucose biosensor based on a poly(brilliant green)-deep eutectic solvent/carbon nanotube modified electrode. Talanta 2019; 208:120427. [PMID: 31816744 DOI: 10.1016/j.talanta.2019.120427] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 09/26/2019] [Accepted: 10/01/2019] [Indexed: 01/21/2023]
Abstract
A highly sensitive glucose oxidase (GOx) electrochemical biosensor for the determination of the biotoxic trace metal ions Hg2+, Cd2+, Pb2+ and CrVI by enzyme inhibition has been developed. GOx was immobilized on a novel sensing platform consisting of poly(brilliant green) films formed by potential cycling electropolymerization in sulfuric acid doped ethaline deep eutectic solvent on multiwalled carbon nanotube modified glassy carbon electrodes. Polymer films produced in this medium presented more uniform morphology and better electrochemical sensing properties than those prepared in aqueous solution. The inhibitor concentration necessary to give 50% inhibition, I50, was used for the determination of the type of reversible inhibition, and the relationship between I50 and the inhibition constant Ki is discussed. The new biosensor was successfully used for the determination of biotoxic trace metal ions with a nanomolar limit of detection, lower than in the literature, very good repeatability, stability and selectivity, and was applied successfully to detection of the toxic trace metal species in milk samples.
Collapse
|
33
|
da Silva W, Ghica ME, Brett CM. Novel nanocomposite film modified electrode based on poly(brilliant cresyl blue)-deep eutectic solvent/carbon nanotubes and its biosensing applications. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2019.06.003] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
34
|
Roda A, Matias AA, Paiva A, Duarte ARC. Polymer Science and Engineering Using Deep Eutectic Solvents. Polymers (Basel) 2019; 11:polym11050912. [PMID: 31117221 PMCID: PMC6572283 DOI: 10.3390/polym11050912] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 05/16/2019] [Accepted: 05/17/2019] [Indexed: 12/12/2022] Open
Abstract
The green and versatile character of deep eutectic solvents (DES) has turned them into significant tools in the development of green and sustainable technologies. For this purpose, their use in polymeric applications has been growing and expanding to new areas of development. The present review aims to summarize the progress in the field of DES applied to polymer science and engineering. It comprises fundamentals studies involving DES and polymers, recent applications of DES in polymer synthesis, extraction and modification, and the early developments on the formulation of DES–polymer products. The combination of DES and polymers is highly promising in the development of new and ‘greener’ materials. Still, there is plenty of room for future research in this field.
Collapse
Affiliation(s)
- Ana Roda
- LAQV, REQUIMTE, Departamento de Química da Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Caparica, Portugal.
- iBET, Instituto de Biologia Experimental e Tecnológica, Apartado 12, 2781-901 Oeiras, Portugal.
| | - Ana A Matias
- iBET, Instituto de Biologia Experimental e Tecnológica, Apartado 12, 2781-901 Oeiras, Portugal.
| | - Alexandre Paiva
- LAQV, REQUIMTE, Departamento de Química da Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Caparica, Portugal.
| | - Ana Rita C Duarte
- LAQV, REQUIMTE, Departamento de Química da Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Caparica, Portugal.
| |
Collapse
|
35
|
Tavakolian-Ardakani Z, Hosu O, Cristea C, Mazloum-Ardakani M, Marrazza G. Latest Trends in Electrochemical Sensors for Neurotransmitters: A Review. SENSORS (BASEL, SWITZERLAND) 2019; 19:E2037. [PMID: 31052309 PMCID: PMC6539656 DOI: 10.3390/s19092037] [Citation(s) in RCA: 66] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 04/07/2019] [Accepted: 04/25/2019] [Indexed: 01/19/2023]
Abstract
Neurotransmitters are endogenous chemical messengers which play an important role in many of the brain functions, abnormal levels being correlated with physical, psychotic and neurodegenerative diseases such as Alzheimer's, Parkinson's, and Huntington's disease. Therefore, their sensitive and robust detection is of great clinical significance. Electrochemical methods have been intensively used in the last decades for neurotransmitter detection, outclassing more complicated analytical techniques such as conventional spectrophotometry, chromatography, fluorescence, flow injection, and capillary electrophoresis. In this manuscript, the most successful and promising electrochemical enzyme-free and enzymatic sensors for neurotransmitter detection are reviewed. Focusing on the activity of worldwide researchers mainly during the last ten years (2010-2019), without pretending to be exhaustive, we present an overview of the progress made in sensing strategies during this time. Particular emphasis is placed on nanostructured-based sensors, which show a substantial improvement of the analytical performances. This review also examines the progress made in biosensors for neurotransmitter measurements in vitro, in vivo and ex vivo.
Collapse
Affiliation(s)
- Zahra Tavakolian-Ardakani
- Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino (Fi), Italy.
- Department of Chemistry, Faculty of Science, Yazd University, Yazd 89195-741, Iran.
| | - Oana Hosu
- Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino (Fi), Italy.
- Department of Analytical Chemistry, Faculty of Pharmacy, "Iuliu Haţieganu" University of Medicine and Pharmacy, 400349 Pasteur 4 Cluj-Napoca, Romania.
| | - Cecilia Cristea
- Department of Analytical Chemistry, Faculty of Pharmacy, "Iuliu Haţieganu" University of Medicine and Pharmacy, 400349 Pasteur 4 Cluj-Napoca, Romania.
| | | | - Giovanna Marrazza
- Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino (Fi), Italy.
- Instituto Nazionale Biostrutture e Biosistemi (INBB), Unit of Florence, Viale delle Medaglie d'Oro 305, 00136 Roma, Italy.
| |
Collapse
|
36
|
Dhingra D, Bhawna, Pandey A, Pandey S. Pyrene Fluorescence To Probe a Lithium Chloride-Added (Choline Chloride + Urea) Deep Eutectic Solvent. J Phys Chem B 2019; 123:3103-3111. [DOI: 10.1021/acs.jpcb.9b01193] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Divya Dhingra
- Department of Chemistry, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | - Bhawna
- Department of Chemistry, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | - Ashish Pandey
- Department of Chemistry, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | - Siddharth Pandey
- Department of Chemistry, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| |
Collapse
|
37
|
Electroplating for Decorative Applications: Recent Trends in Research and Development. COATINGS 2018. [DOI: 10.3390/coatings8080260] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Electroplating processes are widely employed in industrial environments for a large variety of metallic coatings, ranging from technological to decorative applications. Even if the galvanic electrodeposition is certainly a mature technology, new concepts, novel applications, environmental legislation and the new material requirements for next-generation devices make the scientific research in this field still very active. This review focuses mostly at the decorative and wearable applications, and aims to create a bridge between the past knowledge and the future direction that this process, i.e., electrodeposition, is taking. Both the theoretical fundamentals as well as some of the most widespread practical applications—limited to metallic and alloy coatings—are explored. As an integral part of the industrial process, we take a look at the main techniques thought which the quality control of deposits and surfaces is carried out. Finally, global industrial performance and research directions towards sustainable solutions are highlighted.
Collapse
|
38
|
Magnetic solid-phase extraction for the removal of mercury from water with ternary hydrosulphonyl-based deep eutectic solvent modified magnetic graphene oxide. Talanta 2018; 188:454-462. [PMID: 30029401 DOI: 10.1016/j.talanta.2018.06.016] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 05/28/2018] [Accepted: 06/05/2018] [Indexed: 12/12/2022]
Abstract
A novel ternary hydrosulphonyl-based deep eutectic solvent (THS-DES) comprised of choline chloride/itaconic acid/3-mercaptopropionic acid (molar ratio 2:1:1) was firstly synthesized. The composition, property and microscopic structure of the new magnetic adsorbent (THS-DES@M-GO) based on the THS-DES modified the magnetic graphene oxide (M-GO) was characterized by the system. Magnetic solid-phase extraction (MSPE) based THS-DES@M-GO was firstly researched for the removal of mercury (Hg2+) from water. Various influencing factors such as the mass of adsorbent, solution pH, initial Hg2+ concentration, the removal time and temperature had been systematically tested. Under optimized conditions the removal efficiency (R%) could achieved 99.91%. The precision, repeatability and stability experiments were investigated in detail to evaluate the presented method. The relative standard deviations (RSD) of the removal efficiency were 0.053%, 1.49% and 1.55%, respectively. The maximum adsorption capacity (Qmax) was 215.1 mg g-1 and the data of the experiment fitted well with Langmuir model. Elution experimental studies shown that 94.94% of Hg2+ could be eluted by ethylenediaminetetraacetic acid (EDTA). After seven cycles of adsorption-desorption processes, the THS-DES@M-GO still retained a high removal efficiency of 90.23%. Compared with other adsorbents prepared in this work, THS-DES@M-GO displayed higher removal efficiency for Hg2+. Interference study proved the composites was tolerated and stabled under the complex matrix. What's more, the analysis of mercury contaminated water (from Guizhou, P.R., China) proved that the proposed method could be used to remove Hg2+ in practical application.
Collapse
|
39
|
Free-radical polymerizations of and in deep eutectic solvents: Green synthesis of functional materials. Prog Polym Sci 2018. [DOI: 10.1016/j.progpolymsci.2017.09.005] [Citation(s) in RCA: 136] [Impact Index Per Article: 19.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
40
|
Bayındır O, Alanyalıoğlu M. Formation Mechanism of Polymeric Thin Films of Azure B on Gold Electrodes. ChemistrySelect 2018. [DOI: 10.1002/slct.201702699] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Oğuz Bayındır
- Atatürk University; Sciences Faculty; Department of Chemistry; 25240 Erzurum Turkey
| | - Murat Alanyalıoğlu
- Atatürk University; Sciences Faculty; Department of Chemistry; 25240 Erzurum Turkey
| |
Collapse
|
41
|
Nanocomposites based on carbon nanotubes and redox-active polymers synthesized in a deep eutectic solvent as a new electrochemical sensing platform. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2420-z] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|