1
|
Ahmad MB, Arif R, Shaheen A. Multifunctional fluorescent ionic liquid crystals based on L-tryptophan and gemini surfactants for Cu(II) and ascorbic acid detection in real samples. SOFT MATTER 2025. [PMID: 40492868 DOI: 10.1039/d5sm00404g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2025]
Abstract
Ionic liquid crystals (ILCs) represent a promising and innovative subclass of ionic liquids, recognized for their exceptional performance. This study investigates the potential of newly synthesized ILCs, featuring two imidazole rings connected by a three-carbon spacer and the groups of added amino acid L-tryptophan (L-Trp). The ILCs were characterized using FT-IR, 1H NMR, 13C NMR, the mass spectral technique and XRD analysis. Circular dichroism (CD) spectroscopy was applied to examine the chiroptical properties of L-Trp and the synthesized ILCs, [CnIm3OHImCn]·2Trp (n = 12, 14, 16). Confocal laser scanning microscopy (CLSM) was utilized to study the morphology and luminescence of these ILCs. The three distinct ILCs with varying chain lengths were designed and synthesized to function as a novel fluorescent sensor for Cu2+ ion and L-ascorbic acid (AA) detection and their linear range and LOD were found to be 7.97-106 μM and 4.59, 6.22 and 5.11 μM for the former and 3.99-40.00 μM and 3.42, 4.11 and 3.55 μM for the latter analyte. However, the variation of the alkyl chain length for the synthesized ILCs did not show any noticeable effect on their fluorescence behaviour. Job's plot confirmed a 2 : 1 coordination mode between the ILCs and Cu2+ ions. Practical applications were validated through the analysis of real-world samples, specifically for the detection of Cu2+ and AA in real samples like coffee, black tea, green tea and tomato, pomegranate, orange, and human blood serum (HBS), respectively. This study highlights the potential of imidazolium-based ILCs as efficient fluorescent sensors for Cu2+ and AA detection in real sample assessments.
Collapse
Affiliation(s)
| | - Rabia Arif
- Department of Chemistry, Aligarh Muslim University, Aligarh, India.
| | - Arifa Shaheen
- Department of Chemistry, Aligarh Muslim University, Aligarh, India.
| |
Collapse
|
2
|
Sapna K, Sharma V, Kumar M, Kulshrestha V. A modified MXene composite sensor with sulphur impurities for electrochemical detection of lead in the aqueous system. NANOSCALE 2025; 17:7229-7243. [PMID: 40013438 DOI: 10.1039/d4nr05021e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/28/2025]
Abstract
The detection of heavy metal ions, particularly Pb2+, is critical due to their severe environmental and health impacts. This study introduces a novel sensor based on an alkali-modified Ti-MXene decorated with bismuth and sulphur (S-Bi@TiMX), designed for the ultra-sensitive electrochemical detection of Pb2+. Synthesized via hydrothermal deposition, the composite material exhibits a distinctive marigold-like morphology, enhanced active sites, and robust synergistic interactions between its constituents. These features mitigate issues like MXene sheet restacking and promote superior electron transfer kinetics. The composite was drop-cast onto a low-cost, disposable plastic chip electrode (PCE), achieving remarkable sensitivity and an impressive detection limit of 0.0002 μg L-1 Pb2+, well below the WHO safety threshold. The sensor demonstrated good repeatability (RSD < 2.75%), excellent reproducibility (RSD < 2.8%), minimal interference from competing ions, and high recovery rates (99.2%-99.6%) in real water samples. Optimized parameters like pH, preconcentration potential, and time ensured precise, robust performance across a broad linear range (0.01-100 μg L-1). This work highlights the potential of the S-Bi@TiMX/PCE sensor for environmental monitoring and offers a scalable, cost-effective solution for detecting ultra-trace Pb2+ in diverse aqueous systems.
Collapse
Affiliation(s)
- Km Sapna
- Department of Physics, Malaviya National Institute of Technology, JLN Marg, Jaipur-302017, Rajasthan, India.
- CSIR-Central Salt & Marine Chemicals Research Institute, Gijubhai Badheka Marg, Bhavnagar-364002, Gujarat, India.
| | - Vartika Sharma
- CSIR-Central Salt & Marine Chemicals Research Institute, Gijubhai Badheka Marg, Bhavnagar-364002, Gujarat, India.
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad -201002, Uttar Pradesh, India
| | - Manoj Kumar
- Department of Physics, Malaviya National Institute of Technology, JLN Marg, Jaipur-302017, Rajasthan, India.
| | - Vaibhav Kulshrestha
- CSIR-Central Salt & Marine Chemicals Research Institute, Gijubhai Badheka Marg, Bhavnagar-364002, Gujarat, India.
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad -201002, Uttar Pradesh, India
| |
Collapse
|
3
|
Shabbir A, Shahzad SA, Alzahrani AYA, Khan ZA, Yar M, Rauf W. A Multimode fluorescent sensor for sequential detection of Cu 2+ and cysteine as well as pH sensor with real sample Applications: Extensive experimental and DFT studies. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 327:125414. [PMID: 39550819 DOI: 10.1016/j.saa.2024.125414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2024] [Revised: 10/26/2024] [Accepted: 11/05/2024] [Indexed: 11/19/2024]
Abstract
Highly responsive and optically selective (E)-1-((4-phenoxyphenyl) diazenyl)naphthalen-2-ol) sensor PDN with aggregation induced emission enhancement (AIEE) properties has been developed for the sequential detection of Cu2+ and L- Cysteine through fluorescence On-Off-On strategy. The selectivity of sensor depends on the presence of a diazo functional group and its appropriate cavity location in sensor molecule. Azo dye-based (E)-1-((4-phenoxyphenyl) diazenyl)naphthalen-2-ol) sensor PDN has been synthesized by utilizing a simple diazotization synthetic methodology that showed extraordinary AIEE behavior with bathochromic shift owing to the formation of J-aggregates. The morphology and size of aggregates were analyzed by SEM and DLS analysis, respectively. The calculated LOD of sensor PDN for Cu2+, and L-cysteine is 0.113 nM, and 84 nM, respectively. Fluorescence, UV-visible, LC-MS, 1H and 13C NMR titration were carried out to understand the interaction of sensor with Cu2+. The sensor was practically utilized in the sequential sensing of Cu2+ and Cys in real samples. Interestingly, sensor PDN was successfully employed for the sensing of a strong acid and base as well as the detection of Cu2+ ions in the solid state. Moreover, these experimental results were supported through DFT calculations.
Collapse
Affiliation(s)
- Alam Shabbir
- Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, University Road, Abbottabad 22060, Pakistan
| | - Sohail Anjum Shahzad
- Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, University Road, Abbottabad 22060, Pakistan.
| | | | - Zulfiqar Ali Khan
- Department of Chemistry, Government College University Faisalabad, Faisalabad 38000, Pakistan
| | - Muhammad Yar
- Interdisciplinary Research Center in Biomedical Materials (IRCBM), COMSATS University Islamabad, Lahore Campus, Defence Road off Raiwind Road, Lahore 54000, Pakistan
| | - Waqar Rauf
- Health Biotechnology Division, National Institute for Biotechnology and Genetic Engineering, Pakistan Institute of Engineering and Applied Sciences (NIBGE-C, PIEAS), Faisalabad 38000, Pakistan
| |
Collapse
|
4
|
Guo H, Chen B, Luo Y, Wang R, Tian Q, Chang Y. Effect of Bi(iii)-to-metal ion concentration ratios on stripping voltammetric response of bismuth-film glassy carbon electrodes. RSC Adv 2024; 14:39361-39371. [PMID: 39670157 PMCID: PMC11635598 DOI: 10.1039/d4ra07034h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Accepted: 12/03/2024] [Indexed: 12/14/2024] Open
Abstract
The effect of Bi-to-metal ion concentration ratio (c Bi/c M ratio) on key evaluation indicators, including sensitivity, precision, and cathodic potential range, has been investigated for the determination of Cd and Pb at in situ prepared bismuth film electrodes. Unlike the usual recommendation of at least a 10-fold excess of Hg(ii) for anodic stripping experiments at in situ prepared mercury film electrodes, it is found that the c Bi/c M ratios in the 1-10 range are sufficient to obtain a high determination sensitivity, but that the signal decreases significantly when the ratio exceeds 40. Further analysis shows that the precision of the analytical results is good when the c Bi/c M ratio is in the range of 5-10. The precision is even better in the range of 10-20, but too high a ratio cannot further improve the precision of the results. Therefore, it is recommended to keep the c Bi/c M in the range of 5 to 40 to balance the sensitivity and precision in detection. The study also finds that the optimum cathodic potential range is related to the total concentration of metal ions. Therefore, for metals susceptible to hydrogen evolution (e.g., zinc), additional consideration should be given to inhibiting the hydrogen evolution reaction when selecting the c Bi/c M ratio. This work is the first to investigate the effect of the c Bi/c M ratio on the morphology and thickness of deposits using EIS, SEM, and AFM. It is found that increasing the c Bi/c M ratio leads to an increase in the coverage and thickness of the bismuth film on the electrode surface, which enhances the sensitivity of the determination. However, this change is also accompanied by an increase in the electrode resistance, resulting in a significant decrease in signal when the ratio is too large. In addition, when the c Bi/c M ratio is <5, the precision of the bismuth film electrode is relatively poor due to the rapid increase of the bismuth coverage on the electrode surface. The uneven thickening of the deposit also affects the cathodic potential range. Based on these findings, standard curves with c Bi/c M ratios ranging from 5-25 are prepared and successfully applied to the analysis of river water and wastewater.
Collapse
Affiliation(s)
- Hongwei Guo
- School of Chemistry and Environment, Jiaying University Meizhou Guangdong 514015 China
| | - Bin Chen
- School of Chemistry and Environment, Jiaying University Meizhou Guangdong 514015 China
| | - Yingmin Luo
- School of Chemistry and Environment, Jiaying University Meizhou Guangdong 514015 China
| | - Ruiyang Wang
- School of Chemistry and Environment, Jiaying University Meizhou Guangdong 514015 China
| | - Qichang Tian
- School of Chemistry and Environment, Jiaying University Meizhou Guangdong 514015 China
| | - Yanping Chang
- School of Chemistry and Environment, Jiaying University Meizhou Guangdong 514015 China
| |
Collapse
|
5
|
Qi X, Liu P, Yao F, Zhao M, Shen X, Wang Z. Exploring the synchronized effect of MWCNT/X-manganate (X-Cu, Zn) nanocomposite for the sensitive and selective electrochemical detection of Hg(II) and Pb(II) in water. ANAL SCI 2024; 40:2147-2165. [PMID: 39212898 DOI: 10.1007/s44211-024-00652-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2024] [Accepted: 08/11/2024] [Indexed: 09/04/2024]
Abstract
The presence of heavy metal ions in the environment is a long-lasting problem that requires the simultaneous detection of Hg(II) and Pb(II) which is both vital and challenging. This present study examines a simplified and effective approach for synthesizing multi-walled carbon nanotube-copper manganese oxide (MWCNT-CuMn2O4) and multi-walled carbon nanotube-zinc manganese oxide (MWCNT-ZnMn2O4) nanocomposites for electrochemical detection of heavy metal ions. The nanocomposites MWCNT-CuMn2O4 and MWCNT-ZnMn2O4 exceptional electrochemical performance was evaluated using Square Wave Anodic Stripping Voltammetry (SWASV). The fabricated MWCNT-ZnMn2O4 demonstrated lower values of Electrochemical Impedance Spectroscopy (EIS) with charge transfer resistance (Rct) of approximately 34.13 Ω. Remarkably, the MWCNT-ZnMn2O4 electrochemical sensor exhibited the widest linear ranges of 0.5-10 μM with sensitive detection limits (0.011 μM for Hg(II) and 0.014 μM for Pb(II)). Interestingly, the MWCNT-ZnMn2O4 sensor showed excellent capability in detecting Hg(II) and Pb(II) in real water samples with a recovery percentage of 94.1% and 91.3%. Overall, the MWCNT-ZnMn2O4 modified GCE showcased superior selectivity, sensitivity, reproducibility, stability, and repeatability.
Collapse
Affiliation(s)
- Xingpu Qi
- School of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College, No. 8, Fenghuang East Road, Taizhou, 225300, People's Republic of China
| | - Ping Liu
- School of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College, No. 8, Fenghuang East Road, Taizhou, 225300, People's Republic of China
| | - Fang Yao
- School of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College, No. 8, Fenghuang East Road, Taizhou, 225300, People's Republic of China
| | - Mengli Zhao
- School of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College, No. 8, Fenghuang East Road, Taizhou, 225300, People's Republic of China
| | - Xuanyu Shen
- School of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College, No. 8, Fenghuang East Road, Taizhou, 225300, People's Republic of China
| | - Zhengyun Wang
- School of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College, No. 8, Fenghuang East Road, Taizhou, 225300, People's Republic of China.
| |
Collapse
|
6
|
Mecheri N, Lefrada L, Benounis M, Ben Hassine C, Berhoumi H, Mabrouk C. A novel Au-NPs/DBTTA nanocomposite-based electrochemical sensor for the detection of ascorbic acid (AA). SENSOR REVIEW 2024; 44:712-720. [DOI: 10.1108/sr-05-2024-0433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2025]
Abstract
Purpose
Ascorbic acid, a water-soluble antioxidant, is an essential component of the human diet and is known for its potent antioxidant properties against several diseases. In recent years, there has been increasing interest in the development of nonenzymatic sensors due to their simplicity, efficiency and excellent selectivity. The aim of this study is to present a selective and sensitive method for the detection of ascorbic acid in aqueous system using a new electrochemical non-enzymatic sensor based on a gold nanoparticles Au-NPs-1,3-di(4-bromophényl)-5-tert-butyl-1,3,5-triazinane (DBTTA) composite.
Design/methodology/approach
Using the square wave voltammetry (SWV) technique, a series of Au-NPs-DBTTA composites were successfully developed and investigated. First, DBTTA was synthesized via the condensation of tert-butylamine and a4-bromoaniline. The structure obtained was identified by IR, 1H NMR and 13C NMR analysis. A glassy carbon electrode (GCE) was modified with 10–1 M DBTTA dissolved in an aqueous solution by cyclic voltammetry in the potential range of 1–1.4 V. Au-NPs were then deposited on the DBTTA/GCE by a chronoamperometric technique. SWV was used to study the electrochemical behavior of the modified electrode (DBTTA/Au-NPs/GCEs). To observe the effect of nanoparticles, ascorbic acid in a buffer solution was analyzed by SWV at the modified electrode with and without gold nanoparticles (Au-NPs).
Findings
The DBTTA/Au-NPs/GCE showed better electroanalytical results. The detection limit of 10–5 M was obtained and the electrode was proportional to the logarithm of the AA concentration in the range of 5 × 10−3 M to 1 × 10−1 with very good correlation parameters.
Originality/value
It was also found that the elaborated sensor exhibited reproducibility and excellent selectivity against interfering molecules such as uric acid, aspartic acid and glucose. The proposed sensor was tested for the recognition of AA in orange, and satisfactory results were obtained.
Collapse
|
7
|
Zukauskas S, Rucinskiene A, Ramanavicius S, Popov A, Niaura G, Baginskiy I, Zahorodna V, Dukhnovskiy S, Gogotsi O, Ramanavicius A. Electrochemical real-time sensor for the detection of Pb(II) ions based on Ti 3C 2T x MXene. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 950:175190. [PMID: 39094638 DOI: 10.1016/j.scitotenv.2024.175190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Revised: 07/26/2024] [Accepted: 07/30/2024] [Indexed: 08/04/2024]
Abstract
Lead ions are especially harmful to human health, causing significant developmental and behavioral abnormalities even at small concentrations. In real-life samples, lead ions are present in mixtures with other metal ions, creating a challenge to detect it selectively at low quantities. To address these challenges, we prepared an electrochemical sensor based on delaminated Ti3C2Tx MXene, which can selectively detect low concentrations of Pb2+ in a solution containing other common metal ions. Cyclic voltammetry was applied as an electrochemical detection method. The proposed reaction mechanism involves a reversible transition between Pb2+ ions and PbO at the MXene-based layer. The sensitivity of the sensor towards Pb2+ ions and a limit of detection were determined. The sensor, as prepared, had a linear response range within 0.15-1.0 μM, with a sensitivity of 26.7 μA/μM and LOD value of 48.7 nM, which meets the requirements set by the World Health Organization.
Collapse
Affiliation(s)
- Sarunas Zukauskas
- Department of Nanotechnology, Centre for Physical Sciences and Technology, Sauletekio Av. 3, LT-10257 Vilnius, Lithuania.
| | - Alma Rucinskiene
- Department of Electrochemical Material Science, Centre for Physical Sciences and Technology, Sauletekio Av. 3, LT-10257 Vilnius, Lithuania
| | - Simonas Ramanavicius
- Department of Electrochemical Material Science, Centre for Physical Sciences and Technology, Sauletekio Av. 3, LT-10257 Vilnius, Lithuania; Department of Organic Chemistry, Centre for Physical Sciences and Technology, Sauletekio Av. 3, LT-10257 Vilnius, Lithuania
| | - Anton Popov
- NanoTechnas - Center of Nanotechnology and Materials Science, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT-03225 Vilnius, Lithuania
| | - Gediminas Niaura
- Department of Organic Chemistry, Centre for Physical Sciences and Technology, Sauletekio Av. 3, LT-10257 Vilnius, Lithuania
| | - Ivan Baginskiy
- A.J. Drexel Nanomaterials Institute and Materials Science & Engineering Department, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA
| | - Veronika Zahorodna
- Materials Research Center, Ltd., Krzhyzhanovskogo str. 3, Kyiv, Ukraine; A.J. Drexel Nanomaterials Institute and Materials Science & Engineering Department, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA
| | | | - Oleksiy Gogotsi
- Materials Research Center, Ltd., Krzhyzhanovskogo str. 3, Kyiv, Ukraine; A.J. Drexel Nanomaterials Institute and Materials Science & Engineering Department, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA
| | - Arunas Ramanavicius
- Department of Nanotechnology, Centre for Physical Sciences and Technology, Sauletekio Av. 3, LT-10257 Vilnius, Lithuania; Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT-03225 Vilnius, Lithuania.
| |
Collapse
|
8
|
Wahid AA, Usman M, Haleem YA, Ahmed A, Raza K, Munir MU, Pan L, Khan A. Fabrication of a graphene@Ni foam-supported silver nanoplates-PANI 3D architecture electrode for enzyme-free glucose sensing. NANOTECHNOLOGY 2024; 35:495501. [PMID: 39284312 DOI: 10.1088/1361-6528/ad7b41] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Accepted: 09/16/2024] [Indexed: 09/20/2024]
Abstract
Reliable and cost-effective glucose sensors are in rising demand among diabetes patients. The combination of metals and conducting polymers creates a robust electrocatalyst for glucose oxidation, offering enzyme-free, high stability, and sensitivity with outstanding electrochemical results. Herein, graphene is grown on nickel foam by chemical vapor deposition to make a graphene@nickel foam scaffold (G@NF), on which silver nanoplates-polyaniline (Ag-PANI) 3D architecture is developed by sonication-assisted co-electrodeposition. The resulting binder-free 3D Ag-PANI/G@NF electrode was highly porous, as characterized by x-ray photoelectron spectroscopy, Field emission scanning electron microscope, x-ray diffractometer, FTIR, and Raman spectroscopy. The binder-free 3D Ag-PANI/G@NF electrode exhibits remarkable electrochemical efficiency with a superior electrochemical active surface area. The amperometric analysis provides excellent anti-interference performance, a low limit of deduction (0.1 nM), robust sensitivity (1.7 × 1013µA mM-1cm-2), and a good response time. Moreover, the Ag-PANI/G@NF enzyme-free sensor is utilized to observe glucose levels in human blood serums and exhibits excellent potential to become a reliable clinical glucose sensor.
Collapse
Affiliation(s)
- Ahtisham Abdul Wahid
- Institute of Physics, Khwaja Fareed University of Engineering & Information Technology, Rahim Yar Khan 64200, Pakistan
| | - Muhammad Usman
- Institute of Physics, Khwaja Fareed University of Engineering & Information Technology, Rahim Yar Khan 64200, Pakistan
| | - Yasir A Haleem
- Institute of Physics, Khwaja Fareed University of Engineering & Information Technology, Rahim Yar Khan 64200, Pakistan
| | - Arsalan Ahmed
- Interdisciplinary Research Centre in Biomedical Materials, COMSATS University Islamabad, Lahore, Pakistan
| | - Kabeer Raza
- Institute of Metallurgy and Materials Engineering, University of the Punjab, Lahore, Pakistan
| | - Muhammad Usman Munir
- Australian Institute for Bioengineering & Nanotechnology, The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Lujan Pan
- School of Physics, Dalian University of Technology, Dalian 116024, People's Republic of China
| | - Aslam Khan
- Institute of Physics, Khwaja Fareed University of Engineering & Information Technology, Rahim Yar Khan 64200, Pakistan
| |
Collapse
|
9
|
Karagözlü M, Aşır S, Abu Shama N, Göktürk I, Yılmaz F, Türkmen D, Denizli A, Özgören M. Development of Molecularly Imprinted Magnetic Amino Acid-Based Nanoparticles for Voltammetric Analysis of Lead Ions in Honey. Polymers (Basel) 2024; 16:1782. [PMID: 39000638 PMCID: PMC11244471 DOI: 10.3390/polym16131782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Revised: 06/14/2024] [Accepted: 06/20/2024] [Indexed: 07/17/2024] Open
Abstract
Lead (Pb) is a hazardous metal that poses a significant threat to both the environment and human health. The presence of Pb in food products such as honey can pose a significant risk to human health and is therefore important to detect and monitor. In this study, we propose a voltammetric detection method using molecularly imprinted polymer (MIP) electrodes to detect Pb (II) ions in honey. Pb (II) ion-imprinted amino acid-based nanoparticles with magnetic properties on a carbon paste electrode (MIP-CPE) were designed to have high sensitivity and selectivity towards Pb (II) ions in the honey sample. Zetasizer measurements, electron spin resonance, and scanning electron microscopy were used to characterize magnetic polymeric nanoparticles. The results showed that the voltammetric detection method using MIP-CPE was able to accurately detect Pb (II) ions in honey samples with a low detection limit. The proposed method offers a simple, rapid, cost-effective solution for detecting Pb (II) ions in honey. It could potentially be applied to other food products to ensure their safety for human consumption. The MIP-CPE sensor was designed to have high sensitivity and selectivity towards Pb (II) ions in the honey sample. The results showed that the technique was able to deliver highly sensitive results since seven different concentrations were prepared and detected to obtain an R2 of 0.9954, in addition to a low detection limit (LOD) of 0.0912 µM and a low quantification limit (LOQ) of 0.276 µM. Importantly, the analysis revealed no trace of Pb (II) ions in the honey samples obtained from Cyprus.
Collapse
Affiliation(s)
- Mehmet Karagözlü
- Department of Food Engineering, Faculty of Agriculture, Near East University, Nicosia 99138, Cyprus;
- Research Center for Science, Technology and Engineering (BILTEM), Near East University, Nicosia 99138, Cyprus
| | - Süleyman Aşır
- Research Center for Science, Technology and Engineering (BILTEM), Near East University, Nicosia 99138, Cyprus
- Department of Biomedical Engineering, Faculty of Engineering, Near East University, Nicosia 99138, Cyprus
| | - Nemah Abu Shama
- Department of Analytical Chemistry, Faculty of Pharmacy, Near East University, Nicosia 99138, Cyprus
| | - Ilgım Göktürk
- Department of Chemistry, Hacettepe University Ankara, Ankara 06800, Turkey
| | - Fatma Yılmaz
- Department of Chemistry and Chemical Processing Technologies, Bolu Abant Izzet Baysal University, Bolu 14030, Turkey;
| | - Deniz Türkmen
- Department of Chemistry, Hacettepe University Ankara, Ankara 06800, Turkey
| | - Adil Denizli
- Department of Chemistry, Hacettepe University Ankara, Ankara 06800, Turkey
| | - Murat Özgören
- Department of Biophysics, Faculty of Medicine, Near East University, Nicosia 99138, Cyprus;
| |
Collapse
|
10
|
Riesco F, Acosta D, Angulo-Cornejo J, Nagles E. An innovative aluminium foil electrode modified with Al nanoparticles and EDTA for lead detection in biological samples. J Colloid Interface Sci 2024; 663:1052-1063. [PMID: 38452546 DOI: 10.1016/j.jcis.2024.02.208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 02/12/2024] [Accepted: 02/27/2024] [Indexed: 03/09/2024]
Abstract
This study presents a novel Aluminium foil-based electrode characterized by its affordability, flexibility, and ease of modification with carboxylic moiety-containing organic molecules. Upon foil modification with Aluminium nanoparticles and EDTA (AlNP-EDTA/AlE), the modified electrode exhibits remarkable activity in the oxidation of lead at potentials around -0.4 V. The lead signal is derived from the oxidation of lead deposited on the electrode surface using anodic stripping voltammetry (ASV). The addition of EDTA to AlNP/AlE increased the anodic peak current of lead by more than 500 %. The surface characterization of the electrode was performed by scanning electron microscopy (SEM) and infrared spectroscopy (IR), while its electroactive properties were evaluated by cyclic voltammetry (CV) and electrical impedance spectroscopy (EIS). Optimal operating parameters include pH 2.1, square-wave voltammetry (SWV) with an accumulation time of 60 s and an accumulation potential of -0.8 V. A low detection limit of 0.20 µmol/L and a relative standard deviation (RSD) of 3.0 % were achieved using five different electrodes. The effectiveness of AlNP-EDTA/AlE was further demonstrated with consistent results in biological samples spiked with Pb.
Collapse
Affiliation(s)
- Fernando Riesco
- Facultad de Química e Ing. Química, Universidad Nacional Mayor de San Marcos, Lima, Peru.
| | - Dwight Acosta
- Instituto de Física, Universidad Nacional Autónoma de México, Mexico
| | - Jorge Angulo-Cornejo
- Facultad de Química e Ing. Química, Universidad Nacional Mayor de San Marcos, Lima, Peru.
| | - Edgar Nagles
- Facultad de Química e Ing. Química, Universidad Nacional Mayor de San Marcos, Lima, Peru
| |
Collapse
|
11
|
Gupta A, Rotake D, Darji A. Sensing lead ions in water: a comprehensive review on strategies and sensor materials. ANAL SCI 2024; 40:997-1021. [PMID: 38523231 DOI: 10.1007/s44211-024-00547-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 02/25/2024] [Indexed: 03/26/2024]
Abstract
It is well-known fact that elevated lead ions (Pb2+), the third most toxic among heavy metal ions in aqueous systems, pose a threat to human health and aquatic ecosystems when they exceed permissible limits. Pb2+ is commonly found in industrial waste and fertilizers, contaminating water sources and subsequently entering the human body, causing various adverse health conditions. Unlike being expelled, Pb2+ accumulates within the body, posing potential health risks. The harmful impact of presence of Pb2+ in water have prompted researchers to diligently work toward maintaining water quality. Recognizing the importance of Pb2+, this review article makes a sincere and effective effort to address the issues associated with Pb2+. This overview article gives insights into various sensing approaches to detect Pb2+ in water using different sensing materials, including 2-dimensional materials, thiols, quantum dots, and polymers. Herein, different sensing approaches such as electrochemical, optical, field effect transistor-based, micro-electromechanical system-based, and chemi resistive are thoroughly explained. Field effect transistor-based and chemiresistive work on similar principles and are compared on the basis of their fabrication processes and sensing capabilities. In conclusion, future directions for chemiresistive sensors in Pb2+ detection are proposed, emphasizing their simplicity, portability, straightforward functionality, and ease of fabrication. Notably, it sheds light on various thiol and ligand compounds and coupling strategies utilized in Pb2+ detection. This comprehensive study is expected to benefit individuals engaged in Pb2+ detection.
Collapse
Affiliation(s)
- Anju Gupta
- Department of Electronics Engineering, Sardar Vallabhbhai National Institute of Technology, Ichchhanath, Surat, 395007, Gujarat, India
- Department of Biomedical Engineering, Shri Ramdeobaba College of Engineering and Management, Ramdeo Tekdi, Nagpur, 440013, Maharashtra, India
| | - Dinesh Rotake
- Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Hyderabad, 502284, Telangana, India.
| | - Anand Darji
- Department of Electronics Engineering, Sardar Vallabhbhai National Institute of Technology, Ichchhanath, Surat, 395007, Gujarat, India
| |
Collapse
|
12
|
Zhou J, Hu C, Li S, Zhang C, Liu Y, Chen Z, Li S, Chen H, Deng Y. An electrochemical aptasensor based on silver-thiolated graphene for highly sensitive detection of Pb 2. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2905-2912. [PMID: 38660709 DOI: 10.1039/d4ay00322e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
Abstract
The presence of lead ions (Pb2+) in the environment not only leads to environmental contamination but also poses a significant risk to public health through their migration into food and drinking water. Therefore, the development of rapid and effective techniques for detection of trace amounts of Pb2+ is crucial for safeguarding both the environment and biosafety. In this study, an aptamer-based electrochemical sensor was developed for specific detection of Pb2+ by modifying a polylysine (PLL) coated silver-thiolated graphene (Ag-SH-G) nanocomposite (PLL/Ag-SH-G) on the surface of a glassy carbon electrode, which was further modified with gold nanoparticles (AuNPs) for attachment of aptamers (Apt) that specifically recognized Pb2+. The Ag-SH-G particles were synthesized using a one-step in situ method, resulting in significantly enhanced electrochemical properties upon incorporating Ag nanoparticles into the PLL/Ag-SH-G composite. Coating of the covalently or no-covalently bonded Ag-SH-G particles with PLL provides an excellent supporting matrix, facilitating the assembly of AuNPs and a thiol-modified aptamer for Pb2+. Under optimized conditions, Apt/AuNPs/PLL/Ag-SH-G/GCE exhibited excellent sensing performance for Pb2+ with a wide linear response range (10-1000 nM), a low detection limit (0.047 nM) and extraordinary selectivity. The sensor was employed and satisfactory results were obtained in river water, soil and vegetable samples for the detection of Pb2+.
Collapse
Affiliation(s)
- Jie Zhou
- Institute of Cytology and Genetics, School of Basic Medical Sciences, Hengyang Medical School, University of South China, Hengyang, Hunan, 421001, China
- Institute for Future Sciences, University of South China, Changsha, Hunan 410000, China
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, Hunan 412007, China
| | - Changchun Hu
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, Hunan 412007, China
| | - Shuo Li
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, Hunan 412007, China
| | - Chuanxiang Zhang
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, Hunan 412007, China
- College of Packing and Materials Engineering, Hunan University of Technology, Zhuzhou, Hunan 412007, China
| | - Yuan Liu
- Institute of Cytology and Genetics, School of Basic Medical Sciences, Hengyang Medical School, University of South China, Hengyang, Hunan, 421001, China
- Institute for Future Sciences, University of South China, Changsha, Hunan 410000, China
| | - Zhu Chen
- Institute of Cytology and Genetics, School of Basic Medical Sciences, Hengyang Medical School, University of South China, Hengyang, Hunan, 421001, China
- Institute for Future Sciences, University of South China, Changsha, Hunan 410000, China
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, Hunan 412007, China
| | - Song Li
- Institute of Cytology and Genetics, School of Basic Medical Sciences, Hengyang Medical School, University of South China, Hengyang, Hunan, 421001, China
- Institute for Future Sciences, University of South China, Changsha, Hunan 410000, China
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, Hunan 412007, China
- National Health Commission Key Laboratory of Birth Defect Research and Prevention, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, Hunan 410008, China
| | - Hui Chen
- Institute of Cytology and Genetics, School of Basic Medical Sciences, Hengyang Medical School, University of South China, Hengyang, Hunan, 421001, China
- Institute for Future Sciences, University of South China, Changsha, Hunan 410000, China
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, Hunan 412007, China
| | - Yan Deng
- Institute of Cytology and Genetics, School of Basic Medical Sciences, Hengyang Medical School, University of South China, Hengyang, Hunan, 421001, China
- Institute for Future Sciences, University of South China, Changsha, Hunan 410000, China
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, Hunan 412007, China
- National Health Commission Key Laboratory of Birth Defect Research and Prevention, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, Hunan 410008, China
| |
Collapse
|
13
|
Milikić J, Savić M, Janošević Ležaić A, Šljukić B, Ćirić-Marjanović G. Electrochemical Sensing of Cadmium and Lead Ions in Water by MOF-5/PANI Composites. Polymers (Basel) 2024; 16:683. [PMID: 38475366 DOI: 10.3390/polym16050683] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2024] [Revised: 02/19/2024] [Accepted: 02/26/2024] [Indexed: 03/14/2024] Open
Abstract
For the first time, composites of metal-organic framework MOF-5 and conjugated polymer polyaniline (PANI), (MOF-5/PANI), prepared using PANI in its conducting (emeraldine salt, ES) or nonconducting form (emeraldine base, EB) at various MOF-5 and PANI mass ratios, were evaluated as electrode materials for the electrochemical detection of cadmium (Cd2+) and lead (Pb2+) ions in aqueous solutions. Testing of individual components of composites, PANI-ES, PANI-EB, and MOF-5, was also performed for comparison. Materials are characterized by Raman spectroscopy, scanning electron microscopy (SEM) and dynamic light scattering (DLS), and their electrochemical behavior was discussed in terms of their zeta potential, structural, morphology, and textural properties. All examined composites showed high electrocatalytic activity for the oxidation of Cd and Pb to Cd2+ and Pb2+, respectively. The MOF/EB-1 composite (71.0 wt.% MOF-5) gave the highest oxidation currents during both individual and simultaneous detection of two heavy metal ions. Current densities recorded with MOF/EB-1 were also higher than those of its individual components, reflecting the synergistic effect where MOF-5 offers high surface area for two heavy metals adsorption and PANI offers a network for electron transfer during metals' subsequent oxidation. Limits of detection using MOF/EB-1 electrode for Cd2+ and Pb2+ sensing were found to be as low as 0.077 ppm and 0.033 ppm, respectively. Moreover, the well-defined and intense peaks of Cd oxidation to Cd2+ and somewhat lower peaks of Pb oxidation to Pb2+ were observed at voltammograms obtained for the Danube River as a real sample with no pretreatment, which implies that herein tested MOF-5/PANI electrodes could be used as electrochemical sensors for the detection of heavy metal ions in the real water samples.
Collapse
Affiliation(s)
- Jadranka Milikić
- Faculty of Physical Chemistry, University of Belgrade, Studentski Trg 12-16, 11158 Belgrade, Serbia
| | - Marjetka Savić
- Vinča Institute of Nuclear Science, National Institute of the Republic of Serbia, University of Belgrade, 11001 Belgrade, Serbia
| | | | - Biljana Šljukić
- Faculty of Physical Chemistry, University of Belgrade, Studentski Trg 12-16, 11158 Belgrade, Serbia
| | - Gordana Ćirić-Marjanović
- Faculty of Physical Chemistry, University of Belgrade, Studentski Trg 12-16, 11158 Belgrade, Serbia
| |
Collapse
|
14
|
Wen J, Deng H, He D, Yuan Y. Dual-functional DNAzyme powered CRISPR-Cas12a sensor for ultrasensitive and high-throughput detection of Pb 2+ in freshwater. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 911:168708. [PMID: 37992834 DOI: 10.1016/j.scitotenv.2023.168708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 11/17/2023] [Accepted: 11/17/2023] [Indexed: 11/24/2023]
Abstract
Freshwater lead pollution has posed severe threat to the environment and human health, underscoring the urgent necessity for accurate and user-friendly detection methods. Herein, we introduce a novel Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR-Cas) sensor for highly sensitive Pb2+ detection. To accomplish this, we designed a dual-functional deoxyribozyme (df-DNAzyme) probe that functions as an activator for the CRISPR-Cas12a system while also recognizing Pb2+. The df-DNAzyme probe was subsequently combined with gold nanoparticles (AuNPs) to fabricate a DNAzyme/AuNP nanoprobe, facilitating the activation of CRISPR-Cas12a in a one-to-multiple manner. Upon exposure to Pb2+, the df-DNAzyme is cleaved, causing disintegration of the DNAzyme/AuNP nanoprobe from magnetic beads. The degraded DNAzyme/AuNP containing multiple double-stranded DNA activators efficiently triggers CRISPR-Cas12a activity, initiating cleavage of fluorescence-quenched reporter DNA and generating amplified signals accordingly. The amplified fluorescence signal is accurately quantified using a quantitative polymerase chain reaction (qPCR) instrument capable of measuring 96 or 384 samples simultaneously at the microliter scale. This technique demonstrates ultra-sensitive detection capability for Pb2+ at concentrations as low as 1 pg/L within a range from 1 pg/L to 10 μg/L, surpassing limits set by World Health Organization (WHO) and United States Environmental Protection Agency (US EPA) guidelines. This study offers an ultrasensitive and high-throughput method for the detection of Pb2+ in freshwater, thereby advancing a novel approach towards the development of precise and convenient techniques for detecting harmful contaminants.
Collapse
Affiliation(s)
- Junlin Wen
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China.
| | - Hongjie Deng
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China
| | - Daigui He
- Guangdong Mechanical & Electrical Polytechnic, Guangzhou 510550, China
| | - Yong Yuan
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China.
| |
Collapse
|
15
|
Hou X, Cheng Q, Wang H. Self-cleaning paper-based microfluidic biosensor employing DNAzyme and semiconducting single-walled carbon nanotube for copper ion detection. Bioelectrochemistry 2024; 155:108602. [PMID: 37972506 DOI: 10.1016/j.bioelechem.2023.108602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 11/06/2023] [Accepted: 11/07/2023] [Indexed: 11/19/2023]
Abstract
Microfluidic paper-based analytical device (μPAD) offers a simple and efficient platform for point-of-care monitoring, which can be beneficial for copper determination in livestock feed and manure. However, common cellulose paper has excellent hydrophilicity, causing μPAD is accompanied by poor mechanical properties, short service life, and low sensitivity. Here, a self-cleaning paper-based microfluidic biosensor for Cu2+ determination was proposed to overcome the mentioned shortages in the application. Polymeric octadecyl trichlorosilane was synthesized and decorated on cellulose paper to form hydrophobic paper, which can improve the hydrophobicity, self-cleaning, and pollution ability. In addition, hydrophobic paper, semiconducting single-walled carbon nanotube, and DNAzyme through the chemical bond were employed to fabricate a self-cleaning paper-based microfluidic biosensor. The properties were investigated using scanning electron microscopy, Raman, and electrochemical methods. The detecting parameters were also optimized. It could measure the Cu2+ concentration from 1 nM to 100 μM, and the detection limit was 0.65 nM. The self-cleaning paper-based microfluidic biosensor was applied to detect Cu2+ concentration in livestock feed and manure that can meet the requirements for fast screening and detection.
Collapse
Affiliation(s)
- Xiaopeng Hou
- Research Institute of Wood Industry, Chinese Academy of Forestry, Beijing 100091, PR China
| | - Qiongyi Cheng
- Academy of Agricultural Planning and Engineering, No. 41, Maizidian Street, Chaoyang District, Beijing 100125, PR China
| | - Hui Wang
- Research Institute of Wood Industry, Chinese Academy of Forestry, Beijing 100091, PR China; State Key Laboratory of Animal Nutrition and Feeding, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, PR China.
| |
Collapse
|
16
|
Kaur S, Kaur J, Sharma J, Kaur I. S-S bridged Schiff bases as versatile ionophores: Synthesis and application for electrochemical sensing of Copper(II) and Mercury(II). Anal Chim Acta 2024; 1287:342122. [PMID: 38182393 DOI: 10.1016/j.aca.2023.342122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 12/04/2023] [Accepted: 12/06/2023] [Indexed: 01/07/2024]
Abstract
Schiff base derivates (3, 4 and 5) comprising pseudo cavity with different heteroatoms (O, N and S) were designed, synthesized and explored for their detection behaviour towards diverse metal ions. In UV and fluorescence studies, all three receptors exhibited sensitive response towards Cu2+ while 5 showed sensitivity for Hg2+ also. To explore the synthesized receptors for electrochemical behaviour, voltammetric studies were conducted where 3, 4 and 5 exhibited sensitive response towards Cu2+ with detection limits of 9.8 × 10-7 M, 9.0 × 10-7 M and 1.41 × 10-7 M, respectively. The receptor 5 also showed response towards Hg2+ with detection limit of 5.61 × 10-8 M. The formation of complexes, 3/4+Cu2+ and 5+Cu2+/Hg2+ was supported by large values of binding constant and associated negative free energy change. The binding mechanism of 3, 4 and 5 towards respective metal ions was confirmed using 1H-NMR and HR-MS studies. Further, to utilize the proposed sensors for on-site monitoring of analyte metal ions, carbon paste electrodes (CPEs) were constructed by incorporating 3, 4 and 5. All CPEs showed Nernstian response with lower detection limits and excellent selectivity and successfully utilized for the determination of Cu2+ and Hg2+ in groundwater samples.
Collapse
Affiliation(s)
- Sarbjeet Kaur
- Department of Chemistry, UGC-Centre for Advanced Studies, Guru Nanak Dev University, Amritsar-143005, India
| | - Jaspreet Kaur
- Department of Chemistry, UGC-Centre for Advanced Studies, Guru Nanak Dev University, Amritsar-143005, India
| | - Jyanti Sharma
- Department of Chemistry, UGC-Centre for Advanced Studies, Guru Nanak Dev University, Amritsar-143005, India
| | - Inderpreet Kaur
- Department of Chemistry, UGC-Centre for Advanced Studies, Guru Nanak Dev University, Amritsar-143005, India.
| |
Collapse
|
17
|
Chen J, Chen M, Tong H, Wu F, Liu Y, Liu C. Fluorescence biosensor for ultrasensitive detection of the available lead based on target biorecognition-induced DNA cyclic assembly. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 905:167253. [PMID: 37741398 DOI: 10.1016/j.scitotenv.2023.167253] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 08/29/2023] [Accepted: 09/20/2023] [Indexed: 09/25/2023]
Abstract
A fluorescence biosensor was developed for the ultrasensitive detection of the available lead in soil samples by coupling with DNAzyme and hairpin DNA cyclic assembly. The biorecognition between lead and 8-17 DNAzyme will cleave the substrate strands (DNA2) and release the trigger DNA (T), which can be used to initiate the DNA assembly reactions among the hairpins (H1, H2, and H3). The formed Y-shaped sensing scaffold (H1-H2-H3) contains active Mg2+-DNAyzmes at three directions. In the presence of Mg2+, the BHQ and FAM modified H4 will be cleaved by the Mg2+-DNAyzme to generate a high fluorescence signal for lead monitoring. The linear range of the fluorescence biosensor is from 1 pM to 100 nM and the detection limit is 0.2 pM. The biosensor also exhibited high selectivity and the nontarget competing heavy metals did not interfere with the detection results. Compare with the traditional method (DTPA+ICP-MS) for the available lead detection, the relative error (Re) is in the range from -8.3 % to 9.5 %. The results indicated that our constructed fluorescence biosensor is robust, accurate, and reliable, and can be applied directly to the detection of the available lead in soil samples without complex extraction steps.
Collapse
Affiliation(s)
- Junhua Chen
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550081, China; National-Regional Joint Engineering Research Center for Soil Pollution Control and Remediation in South China, Guangdong Key Laboratory of Integrated Agro-environmental Pollution Control and Management, Institute of Eco-environmental and Soil Sciences, Guangdong Academy of Sciences, Guangzhou 510650, China
| | - Manjia Chen
- National-Regional Joint Engineering Research Center for Soil Pollution Control and Remediation in South China, Guangdong Key Laboratory of Integrated Agro-environmental Pollution Control and Management, Institute of Eco-environmental and Soil Sciences, Guangdong Academy of Sciences, Guangzhou 510650, China
| | - Hui Tong
- National-Regional Joint Engineering Research Center for Soil Pollution Control and Remediation in South China, Guangdong Key Laboratory of Integrated Agro-environmental Pollution Control and Management, Institute of Eco-environmental and Soil Sciences, Guangdong Academy of Sciences, Guangzhou 510650, China
| | - Fei Wu
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550081, China
| | - Yizhang Liu
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550081, China
| | - Chengshuai Liu
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550081, China.
| |
Collapse
|
18
|
Xhanari K, Finšgar M. Recent advances in the modification of electrodes for trace metal analysis: a review. Analyst 2023; 148:5805-5821. [PMID: 37697964 DOI: 10.1039/d3an01252b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/13/2023]
Abstract
This review paper summarizes the research published in the last five years on using different compounds and/or materials as modifiers for electrodes employed in trace heavy metal analysis. The main groups of modifiers are identified, and their single or combined application on the surface of the electrodes is discussed. Nanomaterials, film-forming substances, and polymers are among the most used compounds employed mainly in the modification of glassy carbon, screen-printed, and carbon paste electrodes. Composites composed of several compounds and/or materials have also found growing interest in the development of modified electrodes. Environmentally friendly substances and natural products (mainly biopolymers and plant extracts) have continued to be included in the modification of electrodes for trace heavy metal analysis. The main analytical performance parameters of the modified electrodes as well as possible interferences affecting the determination of the target analytes, are discussed. Finally, a critical evaluation of the main findings from these studies and an outlook discussing possible improvements in this area of research are presented.
Collapse
Affiliation(s)
- Klodian Xhanari
- University of Maribor, Faculty of Chemistry and Chemical Engineering, Smetanova ulica 17, 2000 Maribor, Slovenia.
- University of Tirana, Faculty of Natural Sciences, Boulevard "Zogu I", 1001 Tirana, Albania
| | - Matjaž Finšgar
- University of Maribor, Faculty of Chemistry and Chemical Engineering, Smetanova ulica 17, 2000 Maribor, Slovenia.
| |
Collapse
|
19
|
Xia RZ, Cai X, Liang B, Dai HH, Liu YZ, Yang M, Chen SH, Li PH, Huang XJ. Bimodal interferences of Pb(II) induced by parallel deposition in Pb(II)-Cu(II) electrochemical detections: Voltammetric signals analysis combined with numerical simulations on transient interfacial phenomena. JOURNAL OF HAZARDOUS MATERIALS 2023; 459:132104. [PMID: 37490798 DOI: 10.1016/j.jhazmat.2023.132104] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 07/12/2023] [Accepted: 07/18/2023] [Indexed: 07/27/2023]
Abstract
The perplexity of double peaks in Pb(II) detections has been a threat to the reliability of Pb(II) electroanalysis results for a long term. For the complexity of electrode interfaces, rare studies were taken on mechanisms of Pb(II) double peaks through interfacial kinetics. In this work, analyses on experimental signals and interfacial simulations were working together to reveal that the generation of Pb(II) double peaks in Pb(II)-Cu(II) systems is the deposition of Pb(II) on Cu deposits occurring in parallel. By applying anode stripping voltammetry and cyclic voltammetry, a parallel deposition reaction was found to influence the shape of Pb(II) peaks, and the existence of the second peak was controlled through the adjustment of experimental conditions. A kinetic model was built to reveal the interference of electroanalysis signals caused by a parallel deposition reaction and simulations based on the model were combined with experiments to illustrate that double peaks of Pb(II) were caused by the parallel deposition on Cu(II) deposits. This work proposes another insight of Pb(II) double peaks from macroscale kinetics and pays more attention on the dynamic procedure of electroanalysis interfaces, which makes the study on environmental electroanalysis interface phenomena more clear and is enlightening to develop efficient electrical methods for pollutant monitoring.
Collapse
Affiliation(s)
- Rui-Ze Xia
- Department of Materials Science and Engineering, University of Science and Technology of China, Hefei 230026, China; Key Laboratory of Environmental Optics and Technology, And Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China; Institutes of Physical Science and Information Technology, Anhui University, Hefei 230601, China
| | - Xin Cai
- Department of Materials Science and Engineering, University of Science and Technology of China, Hefei 230026, China; Key Laboratory of Environmental Optics and Technology, And Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China
| | - Bo Liang
- Department of Materials Science and Engineering, University of Science and Technology of China, Hefei 230026, China; Key Laboratory of Environmental Optics and Technology, And Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China
| | - Hai-Hua Dai
- Department of Materials Science and Engineering, University of Science and Technology of China, Hefei 230026, China; Key Laboratory of Environmental Optics and Technology, And Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China
| | - Yang-Zhi Liu
- Department of Materials Science and Engineering, University of Science and Technology of China, Hefei 230026, China; Key Laboratory of Environmental Optics and Technology, And Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China
| | - Meng Yang
- Department of Materials Science and Engineering, University of Science and Technology of China, Hefei 230026, China; Key Laboratory of Environmental Optics and Technology, And Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China.
| | - Shi-Hua Chen
- Department of Materials Science and Engineering, University of Science and Technology of China, Hefei 230026, China; Key Laboratory of Environmental Optics and Technology, And Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China.
| | - Pei-Hua Li
- Department of Materials Science and Engineering, University of Science and Technology of China, Hefei 230026, China; Key Laboratory of Environmental Optics and Technology, And Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China.
| | - Xing-Jiu Huang
- Department of Materials Science and Engineering, University of Science and Technology of China, Hefei 230026, China; Key Laboratory of Environmental Optics and Technology, And Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China; Institutes of Physical Science and Information Technology, Anhui University, Hefei 230601, China.
| |
Collapse
|
20
|
Li J, Qi Y, Yang R, Chen X, Chen Z, Zhu JJ. Intellectualized Visualization of Single-Particle Raman Spectra for Sensitive Detection and Simultaneous Multianalysis of Heavy Metal Ions. Anal Chem 2023; 95:14736-14745. [PMID: 37737121 DOI: 10.1021/acs.analchem.3c02851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
Easy-to-use, reliable, and real-time methods for detecting heavy metal ion contamination are urgently required, which is a primary concern for water pollution control and human health. However, present methods for this aim are still unable to achieve simultaneous multianalysis for complex real sample detection. Herein, an intellectualized vision-based single-nanoparticle Raman imaging strategy combined with ion-responsive functional nucleic acids (FNAs) was proposed to address these issues. We reported a correspondence between the concentration of the analytes and the density of particles (DOP) of specifically captured nanoparticles to achieve sensitive detection and simultaneous multianalysis of heavy metal ions. The specific detection of Pb2+ (Hg2+) was obtained with a detection linear range from 100 pM to 100 nM (from 500 fM to 100 nM) and limit of detections low to 1 pM (100 fM), with the advantages of good specificity, excellent homogeneity, and reproducibility. Furthermore, the differentiation of different heavy metal ions (Pb2+/Hg2+) was achieved, i.e., the simultaneous multianalysis, based on Raman imaging of the single particle and intelligent machine vision method. Finally, the Raman imaging assay was utilized for real sample analysis, and it provided a powerful and reliable tool for detecting trace Pb2+/Hg2+ in real water samples and facilitated the portable on-site monitoring of heavy metal ions.
Collapse
Affiliation(s)
- Jinxiang Li
- School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, People's Republic of China
| | - Yongbing Qi
- School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, People's Republic of China
| | - Ruixin Yang
- School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, People's Republic of China
| | - Xueqin Chen
- School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, People's Republic of China
| | - Zixuan Chen
- School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, People's Republic of China
| | - Jun-Jie Zhu
- School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, People's Republic of China
- Shenzhen Research Institute of Nanjing University, Shenzhen 518000, People's Republic of China
| |
Collapse
|
21
|
Gao J, He D, Zhang J, Sun B, Wang G, Suo H, Zhang L, Zhao C. In-situ growth of porous rod-like tungsten oxide for electrochemical determination of cupric ion. Anal Chim Acta 2023; 1276:341645. [PMID: 37573124 DOI: 10.1016/j.aca.2023.341645] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 07/03/2023] [Accepted: 07/20/2023] [Indexed: 08/14/2023]
Abstract
Preconcentration can effectively enhance the detection performance of electrodes in the electrochemical detection of heavy metal ions, but it also presents challenges for real-time monitoring. Several attempts have been made to optimize preconcentration by improving the adsorption capacity or detection mechanism of the electrode. The valence transfer of tungsten oxide between W5+/W6+ can participate in the reduction between the electrode material and heavy metal ions, playing a role in preconcentration to some extent. Therefore, we developed a WO3/SSM electrochemical sensor for the detection of Cu(II) that utilizes the valence variation property of WO3. The crystallinity and microstructure of the WO3/SSM electrode can be regulated by controlling the deposition parameters, and we prepared three types of WO3/SSM with different morphologies to identify the influence of the electrochemical effective surface area. The proposed electrode shows high performance as a Cu(II) sensor under short preconcentration time (60 s), with an excellent sensitivity of 14.113 μA μM-1 cm-2 for 0.1-10.0 μM and 4.7356 μA μM-1 cm-2 for 10.0-20.0 μM. Overall, the combined effect of morphology and valence transfers shortens the preconcentration time and optimizes preconcentration while ensuring excellent electrode performance. This WO3/SSM electrode is expected to drive great advances in the application of tungsten oxide in the electrochemical detection of heavy metal ions.
Collapse
Affiliation(s)
- Jie Gao
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130000, PR China
| | - Dong He
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130000, PR China
| | - Jingwen Zhang
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130000, PR China
| | - Bangning Sun
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130000, PR China
| | - Guanda Wang
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130000, PR China
| | - Hui Suo
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130000, PR China
| | - Liang Zhang
- College of Chemistry and Materials Engineering, Bohai University, Jinzhou, 121013, PR China
| | - Chun Zhao
- State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130000, PR China.
| |
Collapse
|
22
|
Cetin D, Yavuz O, Alcay Y, Semih Yildirim M, Kaplan M, Aribuga H, Ozdemir E, Ertugral U, Yilmaz I. Development of a new near-infrared, spectrophotometric, and colorimetric probe based on phthalocyanine containing mercaptoquinoline unit for discriminative and highly sensitive detection of Ag +, Cu 2+, and Hg 2+ ions. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 297:122725. [PMID: 37075687 DOI: 10.1016/j.saa.2023.122725] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 03/29/2023] [Accepted: 04/09/2023] [Indexed: 05/03/2023]
Abstract
A new near-infrared, spectrophotometric, and colorimetric probe based on a phthalocyanine-containing mercaptoquinoline unit (MQZnPc) has been constructed and utilized for discriminative and highly selective/sensitive detection of Ag+, Cu2+, and Hg2+ ions by using proper masking agents like EDTA, KI, and NaCl. The probe only responds to Ag+, Cu2+, and Hg2+ among the tested ions without any interference. The probe performs quite well (the limit of detection: 160 ppb, 148 ppb, and 276 ppb of Ag+, Cu2+, and Hg2+ions for UV-Vis, and 15 ppb, 37 ppb, and 467 ppb of Ag+, Cu2+, and Hg2+ ions for fluorescence, respectively), and has a fast response time (150 sec, 90 sec, and 90 sec of Ag+, Cu2+, and Hg2+ions for UV-Vis, and 300 sec, 240 sec, and 90 sec Ag+, Cu2+, and Hg2+ions for fluorescence, respectively). The probe also displays a colorimetric feature for UV-Vis and smartphone applications. Based on a single probe, Ag+, Cu2+, and Hg2+ ions which are the main toxic water contaminants could be recognized very quickly and colorimetrically with high recovery values in tap water samples. This study stands out with its unique properties compared to the related studies in the literature.
Collapse
Affiliation(s)
- Dila Cetin
- Istanbul Technical University, Department of Chemistry, 34469 Maslak, Istanbul, Turkey
| | - Ozgur Yavuz
- Istanbul Technical University, Department of Chemistry, 34469 Maslak, Istanbul, Turkey
| | - Yusuf Alcay
- Istanbul Technical University, Department of Chemistry, 34469 Maslak, Istanbul, Turkey
| | | | - Mehmet Kaplan
- Istanbul Technical University, Department of Chemistry, 34469 Maslak, Istanbul, Turkey
| | - Hulya Aribuga
- Istanbul Technical University, Department of Chemistry, 34469 Maslak, Istanbul, Turkey
| | - Emre Ozdemir
- Istanbul Technical University, Department of Chemistry, 34469 Maslak, Istanbul, Turkey
| | - Utku Ertugral
- Istanbul Technical University, Department of Chemistry, 34469 Maslak, Istanbul, Turkey
| | - Ismail Yilmaz
- Istanbul Technical University, Department of Chemistry, 34469 Maslak, Istanbul, Turkey.
| |
Collapse
|
23
|
Elsebai B, Ghica ME, Abbas MN, Brett CMA. Novel Amperometric Mercury-Selective Sensor Based on Organic Chelator Ionophore. Molecules 2023; 28:molecules28062809. [PMID: 36985781 PMCID: PMC10053095 DOI: 10.3390/molecules28062809] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/14/2023] [Accepted: 03/18/2023] [Indexed: 03/30/2023] Open
Abstract
A novel amperometric sensor for the direct determination of toxic mercury ions, Hg2+, based on the organic chelator ionophore N, N di (2-hydroxy-5-[(4-nitrophenyl)diazenyl]benzaldehyde) benzene-1,2-diamine (NDBD), and multiwalled carbon nanotubes (MWCNT) immobilized on a glassy carbon electrode surface was developed. The parameters influencing sensor performance including the ionophore concentration, the applied potential, and electrolyte pH were optimized. The sensor response to Hg2+ was linear between 1-25 µM with a limit of detection of 60 nM. Interferences from other heavy metal ions were evaluated and the sensor showed excellent selectivity towards Hg2+. The method was successfully applied to the determination of mercury ions in milk and water samples.
Collapse
Affiliation(s)
- Basant Elsebai
- Water Pollution Research Department, Environmental and Climate Changes Research Institute, National Research Centre, El-Buhouth St., Dokki, Giza 12622, Egypt
- Department of Chemistry, CEMMPRE, ARISE, University of Coimbra, 3004-535 Coimbra, Portugal
| | - Mariana Emilia Ghica
- Department of Chemistry, CEMMPRE, ARISE, University of Coimbra, 3004-535 Coimbra, Portugal
- Department of Chemical Engineering, CIEPQPF, University of Coimbra, 3030-790 Coimbra, Portugal
| | - Mohammed Nooredeen Abbas
- Applied Organic Chemistry Department, Chemical Industries Research Institute, National Research Centre, El-Buhouth St., Dokki, Giza 12622, Egypt
| | - Christopher M A Brett
- Department of Chemistry, CEMMPRE, ARISE, University of Coimbra, 3004-535 Coimbra, Portugal
| |
Collapse
|
24
|
Li G, Feng S, Yan L, Yang L, Huo B, Wang L, Luo S, Yang D. Direct electrochemical detection of Cu(Ⅱ) ions in juice and tea beverage samples using MWCNTs-BMIMPF6-Nafion modified GCE electrodes. Food Chem 2023; 404:134609. [DOI: 10.1016/j.foodchem.2022.134609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 10/08/2022] [Accepted: 10/11/2022] [Indexed: 11/06/2022]
|
25
|
Incorporating Quartz Crystal Microbalance with Chronoamperometry to Enhance Manganese Detection Stability in Drinking Water. Electrochim Acta 2023. [DOI: 10.1016/j.electacta.2023.142156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2023]
|
26
|
Li QS, Yang Y, Du YD, Cai L, Ma YH, Yang JH, Li M, Meng QJ, Liu QA, Dong WF. Highly sensitive detection of low-concentration sodium chloride solutions based on polymeric nanofilms coated long period fiber grating. Talanta 2023; 254:124126. [PMID: 36446156 DOI: 10.1016/j.talanta.2022.124126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 11/13/2022] [Accepted: 11/21/2022] [Indexed: 11/24/2022]
Abstract
Long period fiber gratings (LPFGs) have special advantages in the detection of salt concentrations due to small volume, corrosion resistance and immunity to electromagnetic interference. However, it is very difficult to distinguish low-concentration salt solutions with usual LPFGs owing to the poor sensitivity. In this paper, the detection capability of the LPFG to low-concentration salt solutions was significantly improved by assembling salt-containing poly (diallyldimethylammonium chloride) (PDDA) and salt-containing poly (sodium-p-styrenesulfonate) (PSS). Experimental results showed that, the responsive wavelength range of the LPFG was remarkably broadened in low-concentration salt solutions after assembling nanofilms. The suitable detection range of the PDDA/PSS films coated LPFG for salt concentrations was 0-3%. In such a range, the average refractive index sensitivity and the average salinity sensitivity of the LPFG was as high as 29545.9 nm/RIU and 52.2 nm/% respectively. Compared with the LPFG without nanofilms, the discrimination ability of the PDDA/PSS films coated LPFG to 0-3% salt solutions increased by 568 times. The analysis demonstrated that PDDA and salt in the assembly solutions played a pivotal role in the above effects. The proposed sensor has extensive application prospects in the monitoring of salt concentration in many fields such as seawater, food processing, fermentation process, etc.
Collapse
Affiliation(s)
- Qiu-Shun Li
- Biology Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250103, China.
| | - Yan Yang
- Biology Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250103, China
| | - Yong-Dong Du
- Biology Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250103, China
| | - Lei Cai
- Biology Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250103, China
| | - Yao-Hong Ma
- Biology Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250103, China
| | - Jun-Hui Yang
- Biology Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250103, China
| | - Mingyu Li
- Department of Optical Engineering, School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun, 130022, China
| | - Qing-Jun Meng
- Biology Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250103, China
| | - Qing-Ai Liu
- Biology Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250103, China
| | - Wen-Fei Dong
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, China.
| |
Collapse
|
27
|
Emerging insights into the use of carbon-based nanomaterials for the electrochemical detection of heavy metal ions. Coord Chem Rev 2023. [DOI: 10.1016/j.ccr.2022.214920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
28
|
Zhu H, Liu M, Liu C, Yu M, Wang K, Li X, Sheng W, Zhu B. Portable ratiometric fluorescence analytical device for copper ions based on smartphone in environment and living organisms. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 857:159488. [PMID: 36265623 DOI: 10.1016/j.scitotenv.2022.159488] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 10/10/2022] [Accepted: 10/12/2022] [Indexed: 06/16/2023]
Abstract
The concentration of copper ions (Cu2+) in the environment is closely related to water quality, food, and biological health. As an indispensable metal element for the human body, its content is closely related to many diseases. However, the current detection methods for Cu2+ have some limitations, such as complicated operations and unfavorable on-site analysis. Therefore, this work constructs a novel ratiometric fluorescent probe (QLP), which has the advantages of rapid response, good anti-interference ability and high sensitivity. It has been successfully used for the detection of Cu2+ in water samples, soil, and food. In addition, low cytotoxicity and strong tissue penetration make it suitable for the detection of Cu2+ in living cells and zebrafish, offering a chemical tool for exploring the physiological and pathological processes related to Cu2+. It is important to use probe QLP and portable UV lamp to create an easy-to-operate Cu2+ detection platform, which can quickly detect Cu2+ on-site by combining with a smartphone. This work not only provides a detection tool for on-site analysis of Cu2+, but also provides a reference strategy for the development of on-site detection methods for other environmental pollutants.
Collapse
Affiliation(s)
- Hanchuang Zhu
- School of Water Conservancy and Environment, University of Jinan, Jinan 250022, China
| | - Mengyuan Liu
- School of Water Conservancy and Environment, University of Jinan, Jinan 250022, China
| | - Caiyun Liu
- School of Water Conservancy and Environment, University of Jinan, Jinan 250022, China.
| | - Miaohui Yu
- Biology Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250103, China
| | - Kun Wang
- School of Water Conservancy and Environment, University of Jinan, Jinan 250022, China
| | - Xinke Li
- School of Water Conservancy and Environment, University of Jinan, Jinan 250022, China
| | - Wenlong Sheng
- Biology Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250103, China.
| | - Baocun Zhu
- School of Water Conservancy and Environment, University of Jinan, Jinan 250022, China.
| |
Collapse
|
29
|
Segura C, Yañez O, Galdámez A, Tapia V, Núñez MT, Osorio-Román I, García C, García-Beltrán O. Synthesis and characterization of a novel colorimetric and fluorometric probe “Turn-on” for the detection of Cu2+ of derivatives rhodamine. J Photochem Photobiol A Chem 2023. [DOI: 10.1016/j.jphotochem.2022.114278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
30
|
Tesfaye E, Chandravanshi BS, Negash N, Tessema M. Development of a new electrochemical method for the determination of copper(ii) at trace levels in environmental and food samples. RSC Adv 2022; 12:35367-35382. [PMID: 36540237 PMCID: PMC9742860 DOI: 10.1039/d2ra06941e] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Accepted: 12/03/2022] [Indexed: 09/10/2023] Open
Abstract
This paper presents the fabrication of a new modified carbon paste electrode (CPE) with N 1-hydroxy-N 1,N 2-diphenylbenzamidine (HDPBA) and functionalized multi-walled carbon nanotubes (MWCNTs) (HDPBA-MWCNTs/CPE) for highly sensitive and selective determination of Cu(ii) using the square wave anodic stripping voltammetry (SWASV) technique. The fabricated electrode was characterized using various spectroscopic techniques to study its morphological, structural, and electrochemical properties. The accumulation of Cu(ii) on the surface of HDPBA-MWCNTs/CPE was done in 0.1 M ammonium chloride (NH4Cl, pH 5) solution at an applied potential of -0.70 V versus Ag/AgCl for 180 s, followed by electrochemical stripping in the positive scan of the voltammetry after a resting time of 10 s. The developed HDPBA-MWCNTs/CPE was found to be highly selective, sensitive and reproducible. At optimal conditions of the experiment, the proposed method exhibited a very low limit of detection (0.0048 nM Cu(ii)), a wide linear dynamic range (0.00007-1.5000 μM Cu(ii)), and good reproducibility with relative standard deviation (RSD) value of 3.7%. The effect of various foreign ions on the voltammetric response of Cu(ii) was investigated and the electrode was found to be highly selective to Cu(ii). The practical applicability of the proposed HDPBA-MWCNTs/CPE was studied by applying the electrode for the quantification of Cu(ii) contents in environmental water (wastewater and tap water), soft drink (Fanta and Sprite), and food supplement (commercially available multi-mineral/vitamin tablets) samples. The present method was validated with atomic absorption spectrometry (AAS). The results found from the two methods are in good agreement with a 95% confidence level.
Collapse
Affiliation(s)
- Endale Tesfaye
- Department of Chemistry, College of Natural and Computational Sciences, Addis Ababa University P.O. Box 1176 Addis Ababa Ethiopia
| | - Bhagwan Singh Chandravanshi
- Department of Chemistry, College of Natural and Computational Sciences, Addis Ababa University P.O. Box 1176 Addis Ababa Ethiopia
| | - Negussie Negash
- Department of Chemistry, College of Natural and Computational Sciences, Addis Ababa University P.O. Box 1176 Addis Ababa Ethiopia
| | - Merid Tessema
- Department of Chemistry, College of Natural and Computational Sciences, Addis Ababa University P.O. Box 1176 Addis Ababa Ethiopia
| |
Collapse
|
31
|
Xavier PF, Benoy M, Ramesh NP, Varghese T. Highly conducting PANI- fMWNT composites with exceptional crystallinity and enhanced thermal stability for potential applications. J SOLID STATE CHEM 2022. [DOI: 10.1016/j.jssc.2022.123638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
32
|
Tesfaye E, Chandravanshi BS, Negash N, Tessema M. A new modified carbon paste electrode using N1-hydroxy-N1,N2-diphenylbenzamidine for the square wave anodic stripping voltammetric determination of Pb(II) in environmental samples. SENSING AND BIO-SENSING RESEARCH 2022. [DOI: 10.1016/j.sbsr.2022.100520] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
33
|
A novel gallium oxide nanoparticles-based sensor for the simultaneous electrochemical detection of Pb 2+, Cd 2+ and Hg 2+ ions in real water samples. Sci Rep 2022; 12:20181. [PMID: 36424461 PMCID: PMC9691749 DOI: 10.1038/s41598-022-24558-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Accepted: 11/16/2022] [Indexed: 11/27/2022] Open
Abstract
Differential pulse voltammetry (DPV) using gallium oxide nanoparticles/carbon paste electrode (Ga2O3/CPE) was utilized for the simultaneous detection of Pb2+, Cd2+ and Hg2+ ions. Ga2O3NPs were chemically synthesized and fully characterized by Fourier-transform infrared (FTIR), X-ray diffraction (XRD), transmission electron microscopy (TEM) and scanning electron microscopy (SEM). Through the assay optimization, electrochemical screening of different nanomaterials was carried out using the cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) in order to determine the best electrode modifier that will be implemented for the present assay. Consequently, various parameters such as electrode matrix composition, electrolyte, deposition potential, and deposition time were optimized and discussed. Accordingly, the newly developed sensing platform showed a wide dynamic linear range of 0.3-80 µM with detection limits (LODs) of 84, 88 and 130 nM for Pb2+, Cd2+ and Hg2+ ions, respectively. While the corresponding limit of quantification (LOQ) values were 280, 320 and 450 nM. Sensors selectivity was investigated towards different non-targeting metal ions, whereas no obvious cross-reactivity was obtained. Eventually, applications on real samples were performed, while excellent recoveries for the multiple metal ions were successfully achieved.
Collapse
|
34
|
Preparation and Application of Electrochemical Horseradish Peroxidase Sensor Based on a Black Phosphorene and Single-Walled Carbon Nanotubes Nanocomposite. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27228064. [PMID: 36432164 PMCID: PMC9694212 DOI: 10.3390/molecules27228064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 10/30/2022] [Accepted: 11/17/2022] [Indexed: 11/22/2022]
Abstract
To design a new electrochemical horseradish peroxidase (HRP) biosensor with excellent analytical performance, black phosphorene (BP) nanosheets and single-walled carbon nanotubes (SWCNTs) nanocomposites were used as the modifier, with a carbon ionic liquid electrode (CILE) as the substrate electrode. The SWCNTs-BP nanocomposite was synthesized by a simple in situ mixing procedure and modified on the CILE surface by the direct casting method. Then HRP was immobilized on the modified electrode with Nafion film. The electrocatalysis of this electrochemical HRP biosensor to various targets was further explored. Experimental results indicated that the direct electrochemistry of HRP was realized with a pair of symmetric and quasi-reversible redox peaks appeared, which was due to the presence of SWCNTs-BP on the surface of CILE, exhibiting synergistic effects with high electrical conductivity and good biocompatibility. Excellent electrocatalytic activity to trichloroacetic acid (TCA), sodium nitrite (NaNO2), and hydrogen peroxide (H2O2) were realized, with a wide linear range and a low detection limit. Different real samples, such as a medical facial peel solution, the soak water of pickled vegetables, and a 3% H2O2 disinfectant, were further analyzed, with satisfactory results, further proving the potential practical applications for the electrochemical biosensor.
Collapse
|
35
|
Synthesis and surface characterization of a chemically modified carbon paste electrode and its application in determination of Hg(II) ions in water, food and dental amalgam samples. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
36
|
Determination of Cd2+ and Pb2+ by polyindole/Mn2O3 nanocomposite and polyindole/Mn2O3/polyaniline nanofibers modified glassy carbon electrode. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-022-02343-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
37
|
Akhdhar A, Yakout AA. Enhanced simultaneous sequestration of Cd(II) and Pb(II) ions from industrial wastewater samples based on poly-(2-aminothiophenol) functionalized graphene oxide. J DISPER SCI TECHNOL 2022. [DOI: 10.1080/01932691.2022.2122495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Affiliation(s)
- Abdullah Akhdhar
- Department of Chemistry, College of Science, University of Jeddah, Saudi Arabia
| | - Amr A. Yakout
- Department of Chemistry, College of Science, University of Jeddah, Saudi Arabia
- Department of Chemistry, Faculty of Science, Alexandria University, Alexandria, Egypt
| |
Collapse
|
38
|
Abstract
Conducting polymers (CPs) are highly conjugated organic macromolecules, where the electrical charge is transported in intra- and inter-chain pathways. Polyacetylene, polythiophene and its derivatives, polypyrrole and its derivatives, and polyaniline are among the best-known examples. These compounds have been used as electrode modifiers to gain sensitivity and selectivity in a large variety of analytical applications. This review, after a brief introduction to the electrochemistry of CPs, summarizes the application of CPs’ electrode interfaces towards heavy metals’ detection using potentiometry, pulse anodic stripping voltammetry, and alternative non-classical electrochemical methods.
Collapse
|
39
|
Lalmalsawmi J, Sarikokba, Tiwari D, Kim DJ. Simultaneous detection of Cd2+ and Pb2+ by differential pulse anodic stripping voltammetry: Use of highly efficient novel Ag0(NPs) decorated silane grafted bentonite material. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
40
|
Bubniene US, Ratautaite V, Ramanavicius A, Bucinskas V. Conducting Polymers for the Design of Tactile Sensors. Polymers (Basel) 2022; 14:polym14152984. [PMID: 35893948 PMCID: PMC9370767 DOI: 10.3390/polym14152984] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/09/2022] [Accepted: 07/20/2022] [Indexed: 11/24/2022] Open
Abstract
This paper provides an overview of the application of conducting polymers (CPs) used in the design of tactile sensors. While conducting polymers can be used as a base in a variety of forms, such as films, particles, matrices, and fillers, the CPs generally remain the same. This paper, first, discusses the chemical and physical properties of conducting polymers. Next, it discusses how these polymers might be involved in the conversion of mechanical effects (such as pressure, force, tension, mass, displacement, deformation, torque, crack, creep, and others) into a change in electrical resistance through a charge transfer mechanism for tactile sensing. Polypyrrole, polyaniline, poly(3,4-ethylenedioxythiophene), polydimethylsiloxane, and polyacetylene, as well as application examples of conducting polymers in tactile sensors, are overviewed. Attention is paid to the additives used in tactile sensor development, together with conducting polymers. There is a long list of additives and composites, used for different purposes, namely: cotton, polyurethane, PDMS, fabric, Ecoflex, Velostat, MXenes, and different forms of carbon such as graphene, MWCNT, etc. Some design aspects of the tactile sensor are highlighted. The charge transfer and operation principles of tactile sensors are discussed. Finally, some methods which have been applied for the design of sensors based on conductive polymers, are reviewed and discussed.
Collapse
Affiliation(s)
- Urte Samukaite Bubniene
- Department of Mechatronics, Robotics and Digital Manufacturing, Faculty of Mechanics, Vilnius Gediminas Technical University, J. Basanaviciaus Str. 28, LT-03224 Vilnius, Lithuania;
- Department of Nanotechnology, State Research Institute Center for Physical Sciences and Technology, Sauletekio Av. 3, LT-10257 Vilnius, Lithuania;
- Correspondence: (U.S.B.); (A.R.)
| | - Vilma Ratautaite
- Department of Nanotechnology, State Research Institute Center for Physical Sciences and Technology, Sauletekio Av. 3, LT-10257 Vilnius, Lithuania;
- Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, LT-03225 Vilnius, Lithuania
| | - Arunas Ramanavicius
- Department of Nanotechnology, State Research Institute Center for Physical Sciences and Technology, Sauletekio Av. 3, LT-10257 Vilnius, Lithuania;
- Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, LT-03225 Vilnius, Lithuania
- Correspondence: (U.S.B.); (A.R.)
| | - Vytautas Bucinskas
- Department of Mechatronics, Robotics and Digital Manufacturing, Faculty of Mechanics, Vilnius Gediminas Technical University, J. Basanaviciaus Str. 28, LT-03224 Vilnius, Lithuania;
| |
Collapse
|
41
|
Vanadium-PEDOT-PANI hybrid nanocomposite modified glassy carbon electrode for enhanced electrochemical and photocatalytic activities. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
42
|
Alshawi JS, Mohammed MQ, Alesary HF, Ismail HK, Barton S. Voltammetric Determination of Hg 2+, Zn 2+, and Pb 2+ Ions Using a PEDOT/NTA-Modified Electrode. ACS OMEGA 2022; 7:20405-20419. [PMID: 35722009 PMCID: PMC9202299 DOI: 10.1021/acsomega.2c02682] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Accepted: 05/24/2022] [Indexed: 06/01/2023]
Abstract
A novel electrochemical sensor for determining trace levels of Hg2+, Pb2+, and Zn2+ ions in water using square wave voltammetry (SWV) is reported. The sensor is based on a platinum electrode (Pt) modified by poly(3,4-ethylenedioxythiophene) and N α,N α-bis-(carboxymethyl)-l-lysine hydrate (NTA lysine) PEDOT/NTA. The modified electrode surface (PEDOT/NTA) was prepared via the introduction of the lysine-NTA group to a PEDOT/N-hydroxyphthalimide NHP electrode. The (PEDOT/NTA) was characterized via cyclic voltammetry (CV), Fourier transform infrared (FTIR) spectroscopy, and scanning electron microscopy (SEM). The effects of scan rates on the electrochemical properties of the polymer electrode were also investigated. The electrochemical results were used to estimate the coverage of the electrode polymer surface and its electrostability in background electrolyte solutions. Several analytical parameters, such as polymer film thickness, metal deposition time, and pH of the electrolyte, were examined. Linear responses to Hg2+, Pb2+, and Zn2+ ions in the concentration range of 5-100 μg L-1 were obtained. The limits of detection (LODs) for the determination of Hg2+, Pb2+, and Zn2+ ions were 1.73, 2.33, and 1.99 μg L-1, respectively. These promising results revealed that modified PEDOT/NTA films might well represent an important addition to existing electrochemical sensor technologies.
Collapse
Affiliation(s)
- Jasim
M. S. Alshawi
- Department
of Chemistry, College of Education for Pure Sciences, University of Basrah, Basrah 61001, Iraq
| | - Mohammed Q. Mohammed
- Department
of Chemistry, College of Education for Pure Sciences, University of Basrah, Basrah 61001, Iraq
| | - Hasan F. Alesary
- Department
of Chemistry, College of Science, University
of Kerbala, Karbala 56001, Iraq
| | - Hani K. Ismail
- Department
of Chemistry, Faculty of Science and Health, Koya University, Koya KOY45, Kurdistan Region −
F.R., Iraq
| | - Stephen Barton
- School
of Life Sciences, Pharmacy and Chemistry, Kingston University London, Kingston-Upon-Thames KT1 1LQ, Surrey, U.K.
| |
Collapse
|
43
|
Shi D, Wu W, Li X. Ultrasensitive detection of mercury(II) ions on a hybrid film of a graphene and gold nanoparticle-modified electrode. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2161-2167. [PMID: 35593172 DOI: 10.1039/d2ay00413e] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Aggravated by human and industrial activities, heavy metal pollution has become a severe problem, causing widespread concern in society, and cannot be ignored. Herein, a graphene/gold nanoparticle-hybrid (AuNPs/ERGO) was proposed and synthesized by electrochemical methods. Based on the AuNPs/ERGO hybrid, a novel electrochemical sensing platform was established and successfully applied for the selective, quantitative detection of Hg2+, taking advantage of the well-established anodic stripping voltammetry (ASV). This hybrid material not only increases the surface area and charge transfer rate but also provides more active sites for Hg deposition due to the formation of homogeneous, high density and monodispersed AuNPs on the ERGO film. The prepared AuNPs/ERGO hybrid was modified on a glassy carbon electrode (GCE) to detect Hg2+ with a linear range from 0.5 to 20 μg L-1 and a low limit of detection (LOD) of 0.06 μg L-1. The selectivity and stability of the as-prepared electrode were investigated and showed promising results. In addition, a screen-printed carbon electrode (SPCE) was also employed to verify the practical application ability of our assay with an excellent performance, which presents a bright application prospect for in situ Hg2+ detection.
Collapse
Affiliation(s)
- Dongmin Shi
- Department of Chemistry, The Hong Kong University of Science and Technology, Kowloon, Hong Kong S.A.R., China.
| | - Wenzhan Wu
- Department of Chemistry, The Hong Kong University of Science and Technology, Kowloon, Hong Kong S.A.R., China.
| | - Xiaoyuan Li
- Department of Chemistry, The Hong Kong University of Science and Technology, Kowloon, Hong Kong S.A.R., China.
| |
Collapse
|
44
|
Physico-Chemical Aspects on Uranium and Molybdenum Extraction from Aqueous Solution by Synthesized Phosphinimine Derivative Chelating Agent. J Inorg Organomet Polym Mater 2022. [DOI: 10.1007/s10904-022-02374-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
45
|
Silver nanowire/graphene oxide electrode for electrochemical detection of lead ions. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-022-02254-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
46
|
Moradpour H, Beitollahi H, Nejad FG, Di Bartolomeo A. Glassy Carbon Electrode Modified with N-Doped Reduced Graphene Oxide Sheets as an Effective Electrochemical Sensor for Amaranth Detection. MATERIALS 2022; 15:ma15093011. [PMID: 35591345 PMCID: PMC9105645 DOI: 10.3390/ma15093011] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Revised: 04/12/2022] [Accepted: 04/18/2022] [Indexed: 02/06/2023]
Abstract
Amaranth is one of the synthetic azo colorants used to improve the appearance and to increase the appeal of some foods and soft drinks. The excessive consumption of amaranth can be associated with health side effects, emphasizing the need to monitor this food dye. Accordingly, the present study aimed to introduce an electrochemical sensor of glassy carbon electrode (GCE) modified with N-doped reduced graphene oxide (N-rGO), N-rGO/GCE, to detect the amaranth sensitively and rapidly. Several electrochemical techniques such as differential pulse voltammetry (DPV), linear sweep voltammetry (LSV), chronoamperometry (CHA), and cyclic voltammetry (CV) are exploited for the evaluation of the efficiency of the developed electrode for the detection of amaranth. We found that N-rGO/GCE enhanced amaranth oxidation, thus significantly elevating the current signal. Amaranth showed that calibration curves ranged from 0.1 to 600.0 µM, and the limit of detection (LOD) (S/N = 3) was 0.03 μM. Finally, the developed sensor was effectively applied for real samples (tap water, apple juice, and orange juice) with acceptable recovery values from 96.0 to 104.3%.
Collapse
Affiliation(s)
- Hediyeh Moradpour
- Department of Chemistry, Graduate University of Advanced Technology, Kerman 7631885356, Iran; (H.M.); (F.G.N.)
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 7631885356, Iran
- Correspondence: (H.B.); (A.D.B.)
| | - Fariba Garkani Nejad
- Department of Chemistry, Graduate University of Advanced Technology, Kerman 7631885356, Iran; (H.M.); (F.G.N.)
| | - Antonio Di Bartolomeo
- Department of Physics “E.R. Caianaiello”, University of Salerno, 84084 Fisciano, Salerno, Italy
- Correspondence: (H.B.); (A.D.B.)
| |
Collapse
|
47
|
Xia Y, Zhao Y, Ai F, Yi Y, Liu T, Lin H, Zhu G. N and P co-doped MXenes nanoribbons for electrodeposition-free stripping analysis of Cu(II) and Hg(II). JOURNAL OF HAZARDOUS MATERIALS 2022; 425:127974. [PMID: 34883378 DOI: 10.1016/j.jhazmat.2021.127974] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 11/29/2021] [Accepted: 11/30/2021] [Indexed: 06/13/2023]
Abstract
The present electrochemical stripping analysis (ESA) for multiple heavy metal ions (HMI) generally requires an electrodeposition process at a very low potential below -1.0 V, which inevitably makes the sensing procedures more complex, inefficient and power-wasting. Meanwhile, the emerging MXenes rising-star materials have been studied in various fields recently. While there are only few reports focusing on the heteroatom doping of MXenes, especially no doping-MXenes for electroanalysis. Based on these issues, a novel multifunctional heteroatoms-doped MXenes nanomaterial, N and P co-doped Ti3C2Tx MXenes nanoribbons (N,P-Ti3C2TxR), was prepared herein for the first time, and then N,P-Ti3C2TxR was used as electrode material to propose an electrodeposition-free ESA strategy for multiple HMI (Cu2+, Hg2+). Owing to the unique spontaneous adsorption and reducing capacities of N,P-Ti3C2TxR towards Cu2+ and Hg2+ coupled with the excellent sensing performances, Cu2+ and Hg2+ can undergo self-reduction to be preconcentrated on N,P-Ti3C2TxR surface with the form of Cu0 and Hg0, thus a simple and ultrasensitive electrodeposition-free ESA platform was developed successfully for the simultaneous detection of Cu2+and Hg2+. This work opened a new pathway for the detection for multiple HMI and the preparation/application of heteroatoms doping MXenes.
Collapse
Affiliation(s)
- Yixuan Xia
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China
| | - Yong Zhao
- Guangzhou Baiyun Airport Customs Comprehensive Technical Service Center, Guangzhou Baiyun Airport Customs District People's Republic of China, Guangzhou 510470, PR China
| | - Fengxiang Ai
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China
| | - Yinhui Yi
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China
| | - Tingting Liu
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China
| | - Huiyu Lin
- Fujian Key Laboratory of Functional Marine Sensing Materials, Ocean College, Minjiang University, PR China
| | - Gangbing Zhu
- School of the Environment and Safety Engineering, Collaborative Innovation Center of Technology and Material of Water Treatment, Jiangsu University, Zhenjiang 212013, PR China; State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, PR China; Fujian Key Laboratory of Functional Marine Sensing Materials, Ocean College, Minjiang University, PR China.
| |
Collapse
|
48
|
Electrochemical determination of Pb2+ and Cd2+ with a poly(pyrrole-1-carboxylic acid) modified electrode. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116221] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
49
|
Gutiérrez IS, Morales VH, Muñoz EMR, Mendoza RN, Soto LL, Ledesma CLP, Casados DS, Pawelec B. Efficient Removal of Hg(II) from Water under Mildly Acidic Conditions with Hierarchical SiO 2 Monoliths Functionalized with -SH Groups. MATERIALS (BASEL, SWITZERLAND) 2022; 15:1580. [PMID: 35208122 PMCID: PMC8874887 DOI: 10.3390/ma15041580] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 02/16/2022] [Accepted: 02/16/2022] [Indexed: 11/21/2022]
Abstract
In this work, novel adsorbents based on 3D hierarchical silica monoliths functionalized with thiol groups were used for the removal of Hg(II) ions from an acidic aqueous solution (pH 3.5). Silica monoliths were synthesized by using two different pluronic triblock polymers (P123 and F127) to study the effect of porous structure on their sorption capacity. Before and after functionalization by grafting with 3-mercaptopropyltrimethoxysilane (MPTMS), the monoliths were characterized by several techniques, and their Hg(II) removal potential was evaluated in batch experiments at 28 °C and pH 3.5, using different initial concentrations of Hg(II) ions in water (200-500 mg L-1). The thiol groups of the monoliths calcined at 550 °C showed thermal stability up to 300 °C (from TG/DTG). The functionalized monolith synthesized with P123 polymer and polyethylene glycol showed favorable hierarchical macro-mesopores for Hg(II) adsorption. M(P123)-SH exhibited 97% removal of Hg(II) at concentration 200 mg L-1. Its maximum adsorption capacity (12.2 mmol g-1) was two times higher than that of M(F127)-SH, demonstrating that the 3D hierarchical macro-mesoporosity allowing accessibility of Hg(II) to thiol groups favors the physical and chemical adsorption of Hg(II) under slightly acidic conditions.
Collapse
Affiliation(s)
- Ireri Segura Gutiérrez
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, Centro Universitario, Cerro de las Campanas, Santiago de Querétaro 76000, Mexico; (I.S.G.); (L.L.S.)
| | - Verónica Hernández Morales
- Centro de Física Aplicada y Tecnología Avanzada, Universidad Nacional Autónoma de México, Campus Juriquilla, Santiago de Querétaro 76230, Mexico; (V.H.M.); (E.M.R.M.); (C.L.P.L.)
| | - Eric Mauricio Rivera Muñoz
- Centro de Física Aplicada y Tecnología Avanzada, Universidad Nacional Autónoma de México, Campus Juriquilla, Santiago de Querétaro 76230, Mexico; (V.H.M.); (E.M.R.M.); (C.L.P.L.)
| | - Rufino Nava Mendoza
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, Centro Universitario, Cerro de las Campanas, Santiago de Querétaro 76000, Mexico; (I.S.G.); (L.L.S.)
| | - Ludwig Lagarde Soto
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, Centro Universitario, Cerro de las Campanas, Santiago de Querétaro 76000, Mexico; (I.S.G.); (L.L.S.)
| | - Carmen Leticia Peza Ledesma
- Centro de Física Aplicada y Tecnología Avanzada, Universidad Nacional Autónoma de México, Campus Juriquilla, Santiago de Querétaro 76230, Mexico; (V.H.M.); (E.M.R.M.); (C.L.P.L.)
| | - Doris Solís Casados
- Centro Conjunto de Investigación en Química Sustentable UAEM-UNAM, Carretera Toluca-Atlacomulco Km 14.5, Unidad San Cayetano, Toluca 50200, Mexico;
| | - Barbara Pawelec
- Instituto de Catálisis y Petroleoquímica, CSIC, Cantoblanco, 28049 Madrid, Spain
| |
Collapse
|
50
|
Self-Referenced Optical Fiber Sensor Based on LSPR Generated by Gold and Silver Nanoparticles Embedded in Layer-by-Layer Nanostructured Coatings. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10020077] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In this work, an optical fiber sensor based on the localized surface plasmon resonance (LSPR) phenomenon has been designed for the detection of two different chemical species (mercury and hydrogen peroxide) by using Layer-by-Layer Embedding (LbL-E) as a nanofabrication technique. In the first step, silver nanoparticles (AgNPs) and gold nanoparticles (AuNPs) have been synthesized by using a chemical protocol as a function of the strict control of three main parameters, which were polyelectrolyte concentration, a loading agent, and a reducing agent. In the second step, their incorporation into nanometric thin films have been demonstrated as a function of the number of bilayers, which shows two well-located absorption peaks associated to their LSPR in the visible region at 420 nm (AgNPs) and 530 nm (AuNPs). Finally, both plasmonic peaks provide a stable real-time reference measurement, which can be extracted from the spectral response of the optical fiber sensor, which shows a specific sensing mechanism as a function of the analyte of study.
Collapse
|