1
|
Almeida JMS, Pedro ZSB, Buoro RM, Brett CMA. Binary and Ternary Deep Eutectic Solvents for Methylene Green Electropolymerization on Multiwalled Carbon Nanotubes: Optimization, Characterization and Application. Chemistry 2024; 30:e202401752. [PMID: 38900538 DOI: 10.1002/chem.202401752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 06/14/2024] [Accepted: 06/20/2024] [Indexed: 06/21/2024]
Abstract
Choline chloride (ChCl) based binary and ternary deep eutectic solvents (DES) were evaluated for methylene green electropolymerization with oxalic acid (OA) and ethylene glycol (EG) as hydrogen bond donors. Binary DES ChCl : OA in molar ratios 1 : 1 and 2 : 1 and ChCl : EG 1 : 2 and ternary DES (tDES) in different molar ratios and percentages of water were evaluated. The highest polymer growth was in ChCl : OA : EG-tDES with 13% added water, that had a lower viscosity and higher ionic conductivity when associated with HCl as dopant. This enhanced the formation of more cation radicals and, consequently, more polymer formation. The PMG/MWCNT/GCE-tDES sensor was successfully applied to the simultaneous determination of 5-aminosalicylic acid (5-ASA) and acetaminophen (APAP) by differential pulse voltammetry in the concentration range 1 μM-200 μM, with detection limits of 0.37 μM and 0.49 μM for 5-ASA and APAP, respectively. The sensor demonstrated good repeatability, reproducibility and stability, and was successfully applied in pharmaceutical formulations.
Collapse
Affiliation(s)
- Joseany M S Almeida
- Department of Chemistry, CEMMPRE, ARISE, Faculty of Sciences and Technology, University of Coimbra, 3004-535, Coimbra, Portugal
| | - Zeferino S B Pedro
- Department of Chemistry, CEMMPRE, ARISE, Faculty of Sciences and Technology, University of Coimbra, 3004-535, Coimbra, Portugal
| | - Rafael M Buoro
- Department of Chemistry and Molecular Physics, São Carlos Chemistry Institute, University of São Paulo, 13566-590, São Carlos, Brazil
| | - Christopher M A Brett
- Department of Chemistry, CEMMPRE, ARISE, Faculty of Sciences and Technology, University of Coimbra, 3004-535, Coimbra, Portugal
| |
Collapse
|
2
|
Zahran M. Conducting dyes as electro-active monomers and polymers for detecting analytes in biological and environmental samples. Heliyon 2023; 9:e19943. [PMID: 37809550 PMCID: PMC10559349 DOI: 10.1016/j.heliyon.2023.e19943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 09/05/2023] [Accepted: 09/06/2023] [Indexed: 10/10/2023] Open
Abstract
Currently, electrochemical sensors are regarded as an efficient tool for the biological and environmental sensing. Electrochemical sensors, such as voltammetric, amperometric, and impedimetric sensors, have gained great attention due to their simplicity, sensitivity, and selectivity. The performance of these electrochemical sensors could be enhanced by surface engineered nano/micro structured materials with conducting dyes/redox species. In this review, a great focus has been put on the redox-active dyes because of their electronic, optical, electrochromic, and conductivity properties. The mechanisms of oxidation and subsequent polymerization of different redox-active dyes at the surface of electrodes have been studied. Additionally, their role in catalyzing the oxidation or reduction of the target analytes at the surfaces of electrodes has also been highlighted. The redox-active dyes were used as electrochemical probes for detecting various analytes in biological and environmental samples. Overall, redox-active dyes are considered promising conducting polymers for the assessment of many analytes such as drugs, pesticides, surfactants, and heavy metal ions.
Collapse
Affiliation(s)
- Moustafa Zahran
- Department of Chemistry, Faculty of Science, El-Menoufia University, Shibin El-Kom, 32512, Egypt
- Menoufia Company for Water and Wastewater, Holding Company for Water and Wastewater, Menoufia, 32514, Egypt
| |
Collapse
|
3
|
Liang X, Zhou Y, Almeida JM, Brett CM. A novel electrochemical acetaminophen sensor based on multiwalled carbon nanotube and poly(neutral red) modified electrodes with electropolymerization in ternary deep eutectic solvents. J Electroanal Chem (Lausanne) 2023. [DOI: 10.1016/j.jelechem.2023.117366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
|
4
|
Tripathi A, Bonilla-Cruz J. Review on Healthcare Biosensing Nanomaterials. ACS APPLIED NANO MATERIALS 2023; 6:5042-5074. [DOI: 10.1021/acsanm.3c00941] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
Affiliation(s)
- Alok Tripathi
- Department of Chemical and Biochemical Engineering, School of Engineering, Indrashil University, Rajpur 382715, Gujarat India
| | - José Bonilla-Cruz
- Advanced Functional Materials and Nanotechnology Group, Centro de Investigación en Materiales Avanzados S. C. (CIMAV-Subsede Monterrey), Avenida Alianza Norte Autopista Monterrey-Aeropuerto Km 10, PIIT, Apodaca, Nuevo León, México C.P. 66628
| |
Collapse
|
5
|
Elsebai B, Ghica ME, Abbas MN, Brett CMA. Novel Amperometric Mercury-Selective Sensor Based on Organic Chelator Ionophore. Molecules 2023; 28:molecules28062809. [PMID: 36985781 PMCID: PMC10053095 DOI: 10.3390/molecules28062809] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/14/2023] [Accepted: 03/18/2023] [Indexed: 03/30/2023] Open
Abstract
A novel amperometric sensor for the direct determination of toxic mercury ions, Hg2+, based on the organic chelator ionophore N, N di (2-hydroxy-5-[(4-nitrophenyl)diazenyl]benzaldehyde) benzene-1,2-diamine (NDBD), and multiwalled carbon nanotubes (MWCNT) immobilized on a glassy carbon electrode surface was developed. The parameters influencing sensor performance including the ionophore concentration, the applied potential, and electrolyte pH were optimized. The sensor response to Hg2+ was linear between 1-25 µM with a limit of detection of 60 nM. Interferences from other heavy metal ions were evaluated and the sensor showed excellent selectivity towards Hg2+. The method was successfully applied to the determination of mercury ions in milk and water samples.
Collapse
Affiliation(s)
- Basant Elsebai
- Water Pollution Research Department, Environmental and Climate Changes Research Institute, National Research Centre, El-Buhouth St., Dokki, Giza 12622, Egypt
- Department of Chemistry, CEMMPRE, ARISE, University of Coimbra, 3004-535 Coimbra, Portugal
| | - Mariana Emilia Ghica
- Department of Chemistry, CEMMPRE, ARISE, University of Coimbra, 3004-535 Coimbra, Portugal
- Department of Chemical Engineering, CIEPQPF, University of Coimbra, 3030-790 Coimbra, Portugal
| | - Mohammed Nooredeen Abbas
- Applied Organic Chemistry Department, Chemical Industries Research Institute, National Research Centre, El-Buhouth St., Dokki, Giza 12622, Egypt
| | - Christopher M A Brett
- Department of Chemistry, CEMMPRE, ARISE, University of Coimbra, 3004-535 Coimbra, Portugal
| |
Collapse
|
6
|
Comment on “Electrochemical Characterisation of Polymelamine Electropolymerised in Deep Eutectic Solvents for Selective Detection of Dopamine”. Electrocatalysis (N Y) 2022. [DOI: 10.1007/s12678-022-00785-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
7
|
Liang X, Zhou Y, Brett CM. Electropolymerisation of brilliant cresyl blue and neutral red on carbon-nanotube modified electrodes in binary and ternary deep eutectic solvents. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
8
|
Dalkiran B, Brett CM. Poly(safranine T)-deep eutectic solvent/copper oxide nanoparticle-carbon nanotube nanocomposite modified electrode and its application to the simultaneous determination of hydroquinone and catechol. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107531] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
9
|
Liu J, Xu Y, Liu S, Yu S, Yu Z, Low SS. Application and Progress of Chemometrics in Voltammetric Biosensing. BIOSENSORS 2022; 12:bios12070494. [PMID: 35884297 PMCID: PMC9313226 DOI: 10.3390/bios12070494] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 07/03/2022] [Accepted: 07/06/2022] [Indexed: 12/14/2022]
Abstract
The voltammetric electrochemical sensing method combined with biosensors and multi-sensor systems can quickly, accurately, and reliably analyze the concentration of the main analyte and the overall characteristics of complex samples. Simultaneously, the high-dimensional voltammogram contains the rich electrochemical features of the detected substances. Chemometric methods are important tools for mining valuable information from voltammetric data. Chemometrics can aid voltammetric biosensor calibration and multi-element detection in complex matrix conditions. This review introduces the voltammetric analysis techniques commonly used in the research of voltammetric biosensor and electronic tongues. Then, the research on optimizing voltammetric biosensor results using classical chemometrics is summarized. At the same time, the incorporation of machine learning and deep learning has brought new opportunities to further improve the detection performance of biosensors in complex samples. Finally, smartphones connected with miniaturized voltammetric biosensors and chemometric methods provide a high-quality portable analysis platform that shows great potential in point-of-care testing.
Collapse
Affiliation(s)
- Jingjing Liu
- College of Automation Engineering, Northeast Electric Power University, Jilin 132012, China; (Y.X.); (S.L.); (S.Y.)
- Correspondence: (J.L.); (S.S.L.)
| | - Yifei Xu
- College of Automation Engineering, Northeast Electric Power University, Jilin 132012, China; (Y.X.); (S.L.); (S.Y.)
| | - Shikun Liu
- College of Automation Engineering, Northeast Electric Power University, Jilin 132012, China; (Y.X.); (S.L.); (S.Y.)
| | - Shixin Yu
- College of Automation Engineering, Northeast Electric Power University, Jilin 132012, China; (Y.X.); (S.L.); (S.Y.)
| | - Zhirun Yu
- College of Law, The Australian National University, Canberra 2600, Australia;
| | - Sze Shin Low
- Research Centre of Life Science and HealthCare, China Beacons Institute, University of Nottingham Ningbo China, 199 Taikang East Road, Ningbo 315100, China
- Correspondence: (J.L.); (S.S.L.)
| |
Collapse
|
10
|
Mukundan A, Feng SW, Weng YH, Tsao YM, Artemkina SB, Fedorov VE, Lin YS, Huang YC, Wang HC. Optical and Material Characteristics of MoS 2/Cu 2O Sensor for Detection of Lung Cancer Cell Types in Hydroplegia. Int J Mol Sci 2022; 23:4745. [PMID: 35563136 PMCID: PMC9101548 DOI: 10.3390/ijms23094745] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 04/21/2022] [Accepted: 04/22/2022] [Indexed: 02/07/2023] Open
Abstract
In this study, n-type MoS2 monolayer flakes are grown through chemical vapor deposition (CVD), and a p-type Cu2O thin film is grown via electrochemical deposition. The crystal structure of the grown MoS2 flakes is analyzed through transmission electron microscopy. The monolayer structure of the MoS2 flakes is verified with Raman spectroscopy, multiphoton excitation microscopy, atomic force microscopy, and photoluminescence (PL) measurements. After the preliminary processing of the grown MoS2 flakes, the sample is then transferred onto a Cu2O thin film to complete a p-n heterogeneous structure. Data are confirmed via scanning electron microscopy, SHG, and Raman mapping measurements. The luminous energy gap between the two materials is examined through PL measurements. Results reveal that the thickness of the single-layer MoS2 film is 0.7 nm. PL mapping shows a micro signal generated at the 627 nm wavelength, which belongs to the B2 excitons of MoS2 and tends to increase gradually when it approaches 670 nm. Finally, the biosensor is used to detect lung cancer cell types in hydroplegia significantly reducing the current busy procedures and longer waiting time for detection. The results suggest that the fabricated sensor is highly sensitive to the change in the photocurrent with the number of each cell, the linear regression of the three cell types is as high as 99%. By measuring the slope of the photocurrent, we can identify the type of cells and the number of cells.
Collapse
Affiliation(s)
- Arvind Mukundan
- Department of Mechanical Engineering, Advanced Institute of Manufacturing with High Tech Innovations (AIM-HI), Center for Innovative Research on Aging Society (CIRAS), National Chung Cheng University, 168, University Rd., Min Hsiung, Chia Yi 62102, Taiwan; (A.M.); (Y.-H.W.); (Y.-M.T.)
| | - Shih-Wei Feng
- Department of Applied Physics, National University of Kaohsiung, 700 Kaohsiung University Rd., Nanzih District, Kaohsiung 81148, Taiwan;
| | - Yu-Hsin Weng
- Department of Mechanical Engineering, Advanced Institute of Manufacturing with High Tech Innovations (AIM-HI), Center for Innovative Research on Aging Society (CIRAS), National Chung Cheng University, 168, University Rd., Min Hsiung, Chia Yi 62102, Taiwan; (A.M.); (Y.-H.W.); (Y.-M.T.)
| | - Yu-Ming Tsao
- Department of Mechanical Engineering, Advanced Institute of Manufacturing with High Tech Innovations (AIM-HI), Center for Innovative Research on Aging Society (CIRAS), National Chung Cheng University, 168, University Rd., Min Hsiung, Chia Yi 62102, Taiwan; (A.M.); (Y.-H.W.); (Y.-M.T.)
| | - Sofya B. Artemkina
- Nikolaev Institute of Inorganic Chemistry, Siberian Branch of Russian Academy of Sciences, 630090 Novosibirsk, Russia; (S.B.A.); (V.E.F.)
- Department of Natural Sciences, Novosibirsk State University, 1, Pirogova str., 630090 Novosibirsk, Russia
| | - Vladimir E. Fedorov
- Nikolaev Institute of Inorganic Chemistry, Siberian Branch of Russian Academy of Sciences, 630090 Novosibirsk, Russia; (S.B.A.); (V.E.F.)
- Department of Natural Sciences, Novosibirsk State University, 1, Pirogova str., 630090 Novosibirsk, Russia
| | - Yen-Sheng Lin
- Department of Electronic Engineering, I-Shou University, No. 1, Sec. 1, Syuecheng Rd., Dashu District, Kaohsiung City 84001, Taiwan;
| | - Yu-Cheng Huang
- Department of Dentistry, Kaohsiung Armed Forces General Hospital, 2, Zhongzheng 1st. Rd., Kaohsiung City 80284, Taiwan
| | - Hsiang-Chen Wang
- Department of Mechanical Engineering, Advanced Institute of Manufacturing with High Tech Innovations (AIM-HI), Center for Innovative Research on Aging Society (CIRAS), National Chung Cheng University, 168, University Rd., Min Hsiung, Chia Yi 62102, Taiwan; (A.M.); (Y.-H.W.); (Y.-M.T.)
| |
Collapse
|
11
|
Leote RJB, Ghica ME, Brett CMA. Pyruvate Oxidase Biosensors Based on Glassy Carbon Electrodes Modified with Carbon Nanotubes and Poly(Neutral Red) Synthesized in Ethaline Deep Eutectic Solvent. ELECTROANAL 2022. [DOI: 10.1002/elan.202100164] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Ricardo J. B. Leote
- University of Coimbra CEMMPRE Department of Chemistry 3004-535 Coimbra Portugal
- National Institute of Materials Physics Atomistilor Str. 405 A 077125 Magurele Romania
| | - Mariana E. Ghica
- University of Coimbra CEMMPRE Department of Chemistry 3004-535 Coimbra Portugal
- University of Coimbra CIEPQPF Department of Chemical Engineering 3030-790 Coimbra Portugal
| | | |
Collapse
|
12
|
da Silva W, Brett CM. Electrosynthesis and characterisation of novel poly(Nile blue)-deep eutectic solvent/Prussian blue nanoparticle modified electrodes and their biosensing application. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
13
|
Svigelj R, Dossi N, Grazioli C, Toniolo R. Deep Eutectic Solvents (DESs) and Their Application in Biosensor Development. SENSORS (BASEL, SWITZERLAND) 2021; 21:4263. [PMID: 34206344 PMCID: PMC8271379 DOI: 10.3390/s21134263] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/11/2021] [Accepted: 06/17/2021] [Indexed: 12/29/2022]
Abstract
Deep Eutectic Solvents (DESs) are a new class of solvents characterized by a remarkable decrease in melting point compared to those of the starting components. The eutectic mixtures can be simply prepared by mixing a Hydrogen Bond Acceptor (HBA) with a Hydrogen Bond Donor (HBD) at a temperature of about 80 °C. They have found applications in different research fields; for instance, they have been employed in organic synthesis, electrochemistry, and bio-catalysis, showing improved biodegradability and lower toxicity compared to other solvents. Herein, we review the use of DESs in biosensor development. We consider the emerging interest in different fields of this green class of solvents and the possibility of their use for the improvement of biosensor performance. We point out some promising examples of approaches for the assembly of biosensors exploiting their compelling characteristics. Furthermore, the extensive ability of DESs to solubilize a wide range of molecules provides the possibility to set up new devices, even for analytes that are usually insoluble and difficult to quantify.
Collapse
Affiliation(s)
- Rossella Svigelj
- Department of Agrifood, Environmental and Animal Science, University of Udine, Via Cotonificio 108, 33100 Udine, Italy; (N.D.); (C.G.)
| | | | | | - Rosanna Toniolo
- Department of Agrifood, Environmental and Animal Science, University of Udine, Via Cotonificio 108, 33100 Udine, Italy; (N.D.); (C.G.)
| |
Collapse
|
14
|
Dalkiran B, Brett CMA. Polyphenazine and polytriphenylmethane redox polymer/nanomaterial-based electrochemical sensors and biosensors: a review. Mikrochim Acta 2021; 188:178. [PMID: 33913010 DOI: 10.1007/s00604-021-04821-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Accepted: 04/02/2021] [Indexed: 12/01/2022]
Abstract
In recent years, an increasing number of studies has demonstrated that redox polymers can be used in simple and effective electrochemical sensing platforms due to their fast electron transfer and electrocatalytic ability. To develop more sensitive and selective electrochemical (bio)sensors, the electrocatalytic properties of redox polymers and the electrical, mechanical, and catalytic properties of various nanomaterials are combined. This review aims to summarize and contribute to the development of (bio)sensors based on polyphenazine or polytriphenylmethane redox polymers combined with nanomaterials, including carbon-based nanomaterials, metal/metal oxide, and semiconductor nanoparticles. The synthesis, preparation, and modification of these nanocomposites is presented and the contribution of each material to the performance of (bio)sensor has been be examined. It is explained how the combined use of these redox polymers and nanomaterials as a sensing platform leads to improved analytical performance of the (bio)sensors. Finally, the analytical performance characteristics and practical applications of polyphenazine and polytriphenylmethane redox polymer/nanomaterial-based electrochemical (bio)sensors are compared and discussed.
Collapse
Affiliation(s)
- Berna Dalkiran
- Department of Chemistry, University of Coimbra, CEMMPRE, 3004-535, Coimbra, Portugal.,Department of Chemistry, Faculty of Science, Ankara University, 06100, Ankara, Turkey
| | - Christopher M A Brett
- Department of Chemistry, University of Coimbra, CEMMPRE, 3004-535, Coimbra, Portugal.
| |
Collapse
|
15
|
Hybrid Nanocomposite Platform, Based on Carbon Nanotubes and Poly(Methylene Blue) Redox Polymer Synthesized in Ethaline Deep Eutectic Solvent for Electrochemical Determination of 5-Aminosalicylic Acid. SENSORS 2021; 21:s21041161. [PMID: 33562228 PMCID: PMC7915580 DOI: 10.3390/s21041161] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 02/04/2021] [Accepted: 02/04/2021] [Indexed: 11/17/2022]
Abstract
A novel hybrid composite of conductive poly(methylene blue) (PMB) and carbon nanotubes (CNT) was prepared for the detection of 5-aminosalicylic acid (5-ASA). Electrosynthesis of PMB with glassy carbon electrode (GCE) or with carbon nanotube modified GCE was done in ethaline deep eutectic solvent of choline chloride mixed with ethylene glycol and a 10% v/v aqueous solution. Different sensor architectures were evaluated in a broad range of pH values in a Britton-Robinson (BR) buffer using electrochemical techniques, chronoamperometry (CA), and differential pulse voltammetry (DPV), to determine the optimum sensor configuration for 5-ASA sensing. Under optimal conditions, the best analytical performance was obtained with CNT/PMBDES/GCE in 0.04 M BR buffer pH 7.0 in the range 5-100 µM 5-ASA using the DPV method, with an excellent sensitivity of 9.84 μA cm-2 μM-1 (4.9 % RSD, n = 5) and a detection limit (LOD) (3σ/slope) of 7.7 nM, outclassing most similar sensors found in the literature. The sensitivity of the same sensor obtained in CA (1.33 μA cm-2 μM-1) under optimal conditions (pH 7.0, Eapp = +0.40 V) was lower than that obtained by DPV. Simultaneous detection of 5-ASA and its analogue, acetaminophen (APAP), was successfully realized, showing a catalytic effect towards the electro-oxidation of both analytes, lowering their oxidation overpotential, and enhancing the oxidation peak currents and peak-to-peak separation as compared with the unmodified electrode. The proposed method is simple, sensitive, easy to apply, and economical for routine analysis.
Collapse
|
16
|
De Alvarenga G, Hryniewicz BM, Jasper I, Silva RJ, Klobukoski V, Costa FS, Cervantes TN, Amaral CD, Schneider JT, Bach-Toledo L, Peralta-Zamora P, Valerio TL, Soares F, Silva BJ, Vidotti M. Recent trends of micro and nanostructured conducting polymers in health and environmental applications. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114754] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
17
|
Wang W, Wang X, Cheng N, Luo Y, Lin Y, Xu W, Du D. Recent advances in nanomaterials-based electrochemical (bio)sensors for pesticides detection. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.116041] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
18
|
Dalkıran B, Fernandes IPG, David M, Brett CMA. Electrochemical synthesis and characterization of poly(thionine)-deep eutectic solvent/carbon nanotube-modified electrodes and application to electrochemical sensing. Mikrochim Acta 2020; 187:609. [PMID: 33057990 DOI: 10.1007/s00604-020-04588-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 10/01/2020] [Indexed: 01/09/2023]
Abstract
Electropolymerization of thionine (TH) on multiwalled carbon nanotube (MWCNT)-modified glassy carbon electrodes (GCE) in ethaline deep eutectic solvent (DES) was carried out for the first time, to prepare poly(thionine) (PTH) films with different nanostructured morphologies. PTH films were formed on MWCNT/GCE by potential cycling electropolymerization in ethaline with the addition of different acid dopants CH3COOH, HClO4, HNO3, H2SO4 and HCl, acetic acid being the best. The electropolymerization process was monitored with an electrochemical quartz crystal microbalance. The polymerization scan rate was a key factor affecting the electrochemical and morphological properties of the PTHEthaline-CH3COOH/MWCNT/GCE; electrodeposition at 200 mV s-1 showing the best performance. The PTH/MWCNT/GCE platform was characterized using cyclic and differential pulse voltammetry, electrochemical impedance spectroscopy and scanning electron microscopy. The analytical characteristics of the PTH films were evaluated for sensing of ascorbic acid and biosensing of uric acid. The developed sensor exhibited a low detection limit (1.1 μM), wide linear range (2.8-3010 μM) and high sensitivity (1134 μA cm-2 mM-1) for ascorbic acid. After immobilization of uricase, UOx, on PTH/MWCNT/GCE, the biosensor was successfully applied to the determination of uric acid, with fast response (˂ 7 s), good sensitivity (450 μA cm-2 mM-1, wide linear range (0.48-279 μM) and low detection limit (58.9 nM), better than in the literature and than with PTH prepared in aqueous solution. The determination of uric acid in synthetic urine samples was successfully tested and the mean analytical recovery was 100.8 ± 1.4%. This is a promising approach for the determination of uric acid in real samples. Graphical abstract.
Collapse
Affiliation(s)
- Berna Dalkıran
- CEMMPRE, Department of Chemistry, University of Coimbra, 3004-535, Coimbra, Portugal
| | - Isabel P G Fernandes
- CEMMPRE, Department of Chemistry, University of Coimbra, 3004-535, Coimbra, Portugal
| | - Melinda David
- CEMMPRE, Department of Chemistry, University of Coimbra, 3004-535, Coimbra, Portugal
| | - Christopher M A Brett
- CEMMPRE, Department of Chemistry, University of Coimbra, 3004-535, Coimbra, Portugal.
| |
Collapse
|
19
|
da Silva W, Brett CM. Novel biosensor for acetylcholine based on acetylcholinesterase/poly(neutral red) – Deep eutectic solvent/Fe2O3 nanoparticle modified electrode. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114050] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
20
|
Shishov A, Pochivalov A, Nugbienyo L, Andruch V, Bulatov A. Deep eutectic solvents are not only effective extractants. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115956] [Citation(s) in RCA: 73] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
21
|
Raymundo-Pereira PA, Silva TA, Caetano FR, Ribovski L, Zapp E, Brondani D, Bergamini MF, Marcolino LH, Banks CE, Oliveira ON, Janegitz BC, Fatibello-Filho O. Polyphenol oxidase-based electrochemical biosensors: A review. Anal Chim Acta 2020; 1139:198-221. [PMID: 33190704 DOI: 10.1016/j.aca.2020.07.055] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 07/14/2020] [Accepted: 07/20/2020] [Indexed: 02/06/2023]
Abstract
The detection of phenolic compounds is relevant not only for their possible benefits to human health but also for their role as chemical pollutants, including as endocrine disruptors. The required monitoring of such compounds on-site or in field analysis can be performed with electrochemical biosensors made with polyphenol oxidases (PPO). In this review, we describe biosensors containing the oxidases tyrosinase and laccase, in addition to crude extracts and tissues from plants as enzyme sources. From the survey in the literature, we found that significant advances to obtain sensitive, robust biosensors arise from the synergy reached with a diversity of nanomaterials employed in the matrix. These nanomaterials are mostly metallic nanoparticles and carbon nanostructures, which offer a suitable environment to preserve the activity of the enzymes and enhance electron transport. Besides presenting a summary of contributions to electrochemical biosensors containing PPOs in the last five years, we discuss the trends and challenges to take these biosensors to the market, especially for biomedical applications.
Collapse
Affiliation(s)
| | - Tiago A Silva
- Departamento de Metalurgia e Química, Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), 35180-008, Timóteo, MG, Brazil
| | - Fábio R Caetano
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal Do Paraná (UFPR), 81.531-980, Curitiba, PR, Brazil
| | - Laís Ribovski
- São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, Brazil
| | - Eduardo Zapp
- Department of Exact Sciences and Education, Federal University of Santa Catarina, 89036-256, Brazil
| | - Daniela Brondani
- Department of Exact Sciences and Education, Federal University of Santa Catarina, 89036-256, Brazil
| | - Marcio F Bergamini
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal Do Paraná (UFPR), 81.531-980, Curitiba, PR, Brazil
| | - Luiz H Marcolino
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal Do Paraná (UFPR), 81.531-980, Curitiba, PR, Brazil
| | - Craig E Banks
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester, M1 5GD, UK
| | - Osvaldo N Oliveira
- São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, Brazil
| | - Bruno C Janegitz
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, 13600-970, Araras, SP, Brazil.
| | - Orlando Fatibello-Filho
- Department of Chemistry, Federal University of São Carlos, 13560-970, São Carlos, SP, Brazil.
| |
Collapse
|
22
|
da Silva W, Queiroz AC, Brett CM. Nanostructured Poly(Phenazine)/Fe2O3 nanoparticle film modified electrodes formed by electropolymerization in ethaline - Deep eutectic solvent. Microscopic and electrochemical characterization. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.136284] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
23
|
Kuzin YI, Padnya PL, Stoikov II, Gorbatchuk VV, Stoikov DI, Khadieva AI, Evtugyn GA. Electrochemical behavior of the monomeric and polymeric forms of N-phenyl-3-(phenylimino)-3H-phenothiazin-7-amine. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.136195] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
24
|
Sanz CG, Serrano SHP, Brett CMA. Electroanalysis of Cefadroxil Antibiotic at Carbon Nanotube/Gold Nanoparticle Modified Glassy Carbon Electrodes. ChemElectroChem 2020. [DOI: 10.1002/celc.202000255] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Affiliation(s)
- Caroline G. Sanz
- University of Coimbra, CEMMPREFaculty of Sciences and Technology, Department of Chemistry 3004-535 Coimbra Portugal
- Department of Fundamental Chemistry, Institute of ChemistryUniversity of São Paulo 05508-000 São Paulo/SP Brazil
| | - Silvia H. P. Serrano
- Department of Fundamental Chemistry, Institute of ChemistryUniversity of São Paulo 05508-000 São Paulo/SP Brazil
| | - Christopher M. A. Brett
- University of Coimbra, CEMMPREFaculty of Sciences and Technology, Department of Chemistry 3004-535 Coimbra Portugal
| |
Collapse
|
25
|
Gao Y, Wang Y, Yan Y, Tang K, Ding CF. Self-assembly of poly(ionic liquid) functionalized mesoporous magnetic microspheres for the solid-phase extraction of preservatives from milk samples. J Sep Sci 2019; 43:766-773. [PMID: 31746547 DOI: 10.1002/jssc.201900851] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 11/03/2019] [Accepted: 11/13/2019] [Indexed: 11/09/2022]
Abstract
In this work, a novel, rapid, and simple analytical method was proposed for the detection of parabens in milk sample by gas chromatography coupled with mass spectrometry. At the same time, milk sample was pretreated by magnetic solid phase extraction, which detected up to five parabens. A series of important parameters of magnetic solid phase extraction were investigated and optimized, such as pH value of loading buffer, amount of material, adsorption time, ionic strength, eluting solvents, and eluting time. Under the optimized conditions, the corresponding values were more than 0.9991, limits of detection and the limit of quantification were 0.1 and 0.5 ng/mL, respectively. In addition, the recoveries were achieved in range of 95-105%, the liner range were within 0.1-600 ng/mL, and the relative standard deviations were even lower than 5%.
Collapse
Affiliation(s)
- Yiqian Gao
- School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, P. R. China
| | - Yucen Wang
- Ningbo Foreign Language School, Ningbo, P. R. China
| | - Yinghua Yan
- School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, P. R. China
| | - Keqi Tang
- School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, P. R. China
| | - Chuan-Fan Ding
- School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, P. R. China
| |
Collapse
|
26
|
Pirzada M, Altintas Z. Nanomaterials for Healthcare Biosensing Applications. SENSORS (BASEL, SWITZERLAND) 2019; 19:E5311. [PMID: 31810313 PMCID: PMC6928990 DOI: 10.3390/s19235311] [Citation(s) in RCA: 86] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 11/22/2019] [Accepted: 11/27/2019] [Indexed: 12/12/2022]
Abstract
In recent years, an increasing number of nanomaterials have been explored for their applications in biomedical diagnostics, making their applications in healthcare biosensing a rapidly evolving field. Nanomaterials introduce versatility to the sensing platforms and may even allow mobility between different detection mechanisms. The prospect of a combination of different nanomaterials allows an exploitation of their synergistic additive and novel properties for sensor development. This paper covers more than 290 research works since 2015, elaborating the diverse roles played by various nanomaterials in the biosensing field. Hence, we provide a comprehensive review of the healthcare sensing applications of nanomaterials, covering carbon allotrope-based, inorganic, and organic nanomaterials. These sensing systems are able to detect a wide variety of clinically relevant molecules, like nucleic acids, viruses, bacteria, cancer antigens, pharmaceuticals and narcotic drugs, toxins, contaminants, as well as entire cells in various sensing media, ranging from buffers to more complex environments such as urine, blood or sputum. Thus, the latest advancements reviewed in this paper hold tremendous potential for the application of nanomaterials in the early screening of diseases and point-of-care testing.
Collapse
Affiliation(s)
| | - Zeynep Altintas
- Technical University of Berlin, Straße des 17. Juni 124, 10623 Berlin, Germany;
| |
Collapse
|
27
|
Hopkins J, Fidanovski K, Lauto A, Mawad D. All-Organic Semiconductors for Electrochemical Biosensors: An Overview of Recent Progress in Material Design. Front Bioeng Biotechnol 2019; 7:237. [PMID: 31608275 PMCID: PMC6773807 DOI: 10.3389/fbioe.2019.00237] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Accepted: 09/11/2019] [Indexed: 12/20/2022] Open
Abstract
Organic semiconductors remain of major interest in the field of bioelectrochemistry for their versatility in chemical and electrochemical behavior. These materials have been tailored using organic synthesis for use in cell stimulation, sustainable energy production, and in biosensors. Recent progress in the field of fully organic semiconductor biosensors is outlined in this review, with a particular emphasis on the synthetic tailoring of these semiconductors for their intended application. Biosensors ultimately function on the basis of a physical, optical or electrochemical change which occurs in the active material when it encounters the target analyte. Electrochemical biosensors are becoming increasingly popular among organic semiconductor biosensors, owing to their good detection performances, and simple operation. The analyte either interacts directly with the semiconductor material in a redox process or undergoes a redox process with a moiety such as an enzyme attached to the semiconductor material. The electrochemical signal is then transduced through the semiconductor material. The most recent examples of organic semiconductor biosensors are discussed here with reference to the material design of polymers with semiconducting backbones, specifically conjugated polymers, and polymer semiconducting dyes. We conclude that direct interaction between the analyte and the semiconducting material is generally more sensitive and cost effective, despite being currently limited by the need to identify, and synthesize selective sensing functionalities. It is also worth noting the potential roles of highly-sensitive, organic transistor devices and small molecule semiconductors, such as the photochromic and redox active molecule spiropyran, as polymer pendant groups in future biosensor designs.
Collapse
Affiliation(s)
- Jonathan Hopkins
- School of Materials Science and Engineering, University of New South Wales Sydney, Sydney, NSW, Australia.,Centre for Advanced Macromolecular Design, University of New South Wales Sydney, Sydney, NSW, Australia
| | - Kristina Fidanovski
- School of Materials Science and Engineering, University of New South Wales Sydney, Sydney, NSW, Australia.,Centre for Advanced Macromolecular Design, University of New South Wales Sydney, Sydney, NSW, Australia
| | - Antonio Lauto
- School of Science, Western Sydney University, Penrith, NSW, Australia
| | - Damia Mawad
- School of Materials Science and Engineering, University of New South Wales Sydney, Sydney, NSW, Australia.,Centre for Advanced Macromolecular Design, University of New South Wales Sydney, Sydney, NSW, Australia.,Australian Centre for NanoMedicine, ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, University of New South Wales Sydney, Sydney, NSW, Australia
| |
Collapse
|