1
|
Cimmino W, Esposito S, Kalligosfyri PM, Iaccarino N, Cinti S. Chemometrics-Assisted Enhancement of Electrochemical Biosensor Performance toward miRNA Detection. Anal Chem 2025; 97:8182-8188. [PMID: 40217571 PMCID: PMC12019774 DOI: 10.1021/acs.analchem.4c05402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2024] [Revised: 03/04/2025] [Accepted: 04/04/2025] [Indexed: 04/14/2025]
Abstract
Chemometrics represents a potent tool for optimizing the experimental setup and subsequently boosting the performance of analytical methods. In particular, design of experiments (DoE) allows the experimental conditions to be optimized with high accuracy and a lower number of experiments when compared with the classical univariate approach, also known as one variable at a time (OVAT), which provides only a partial understanding on how factors affect the response. In this work, DoE was exploited, specifically a D-optimal design was used, to improve the analytical performance of a hybridization-based paper-based electrochemical biosensor, taking as target of the study the miRNA-29c (miR-29c) that is related to triple negative breast cancer. The sensing platform is composed of six variables to be optimized, including both those related to the sensor's manufacture (i.e., gold nanoparticles, immobilized DNA probe) and those related to the working conditions (i.e., ionic strength, probe-target hybridization, electrochemical parameters). The adoption of DoE allowed us to optimize the device using only 30 experiments with respect to the 486 that would have been required with the OVAT approach, and as a consequence of the more accurate optimal conditions that have been reached, the detection of miRNA was more sensitive and repeatable when compared with previous data reported using the univariate approach for optimization, leading to a 5-fold limit of detection (LOD) improvement toward miRNA. It confirms that chemometrics might be considered a fundamental tool to be used in the development of various kinds of sensors and biosensors.
Collapse
Affiliation(s)
- Wanda Cimmino
- Department
of Pharmacy, University of Naples “Federico
II”, 80131 Naples, Italy
| | - Simona Esposito
- Department
of Pharmacy, University of Naples “Federico
II”, 80131 Naples, Italy
| | | | - Nunzia Iaccarino
- Department
of Pharmacy, University of Naples “Federico
II”, 80131 Naples, Italy
| | - Stefano Cinti
- Department
of Pharmacy, University of Naples “Federico
II”, 80131 Naples, Italy
- Sbarro
Institute for Cancer Research and Molecular Medicine, Center for Biotechnology,
College of Science and Technology, Temple
University, Philadelphia, Pennsylvania 19122, United States
| |
Collapse
|
2
|
Reséndiz-Jaramillo AY, Mendoza-Camargo AP, Ortiz-Contreras OE, Rodríguez-Morales JA, Huerta-Manzanilla EL, Escalona-Villalpando RA, Ledesma-García J. The importance of factorial design on the optimization of biosensor performance: immobilization of glucose oxidase as a case study. Anal Bioanal Chem 2024; 416:6849-6858. [PMID: 39395049 DOI: 10.1007/s00216-024-05582-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2024] [Revised: 09/23/2024] [Accepted: 09/27/2024] [Indexed: 10/14/2024]
Abstract
Conventionally, the optimization of glucose biosensors is achieved by varying the concentrations of the individual reagents used to immobilize the enzyme. In this work, the effect and interaction between glucose oxidase enzyme (GOx), ferrocene methanol (Fc), and multi-walled carbon nanotubes (MWCNTs) at different concentrations were investigated by a design of experiments (DoE). For this analysis, a factorial design with three factors and two levels each was used with the software RStudio for statistical analysis. The data were obtained by electrochemical experiments on the immobilization of GOx-Fc/MWCNT at different concentrations. The results showed that the factorial DoE method was confirmed by the non-normality of the residuals and the outliers of the experiment. When examining the effects of the variables, analyzing the half-normal distribution and the effects and contrasts for GOx-Fc/MWCNT, the factors that showed the greatest influence on the electrochemical response were GOx, MWCNT, Fc, and MWCNT:Fc, and there is a high correlation between the factors GOx, MWCNT, Fc, and MWCNT:Fc, as shown by the analysis of homoscedasticity and multicollinearity. With these statistical analyses and experimental designs, it was possible to find the optimal conditions for different factors: 10 mM mL-1 GOx, 2 mg mL-1 Fc, and 15 mg mL-1 MWCNT show a greater amperometric response in the glucose oxidation. This work contributes to advancing enzyme immobilization strategies for glucose biosensor applications. Systematic investigation of DoE leads to optimized immobilization for GOx, enables better performance as a glucose biosensor, and allows the prediction of some outcomes.
Collapse
Affiliation(s)
- A Y Reséndiz-Jaramillo
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, 76010, Santiago de Querétaro, Mexico
| | - A P Mendoza-Camargo
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, 76010, Santiago de Querétaro, Mexico
| | - O E Ortiz-Contreras
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, 76010, Santiago de Querétaro, Mexico
| | - J A Rodríguez-Morales
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, 76010, Santiago de Querétaro, Mexico
| | - Eric L Huerta-Manzanilla
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, 76010, Santiago de Querétaro, Mexico
| | - Ricardo A Escalona-Villalpando
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, 76010, Santiago de Querétaro, Mexico.
| | - J Ledesma-García
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, 76010, Santiago de Querétaro, Mexico.
| |
Collapse
|
3
|
Janfaza S, Radha Shanmugam N, Jolly P, Kovur P, Singh U, Mackay S, Wishart D, Ingber DE. Redox-Modified Nanostructured Electrochemical Surfaces for Continuous Glucose Monitoring in Complex Biological Fluids. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:796. [PMID: 38727390 PMCID: PMC11085330 DOI: 10.3390/nano14090796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Revised: 04/29/2024] [Accepted: 05/01/2024] [Indexed: 05/12/2024]
Abstract
Continuous glucose monitoring is valuable for people with diabetes but faces limitations due to enzyme-electrode interactions and biofouling from biological samples that reduce sensor sensitivity and the monitoring performance. We created an enzyme-based electrochemical system with a unique nanocomposite coating that incorporates the redox molecule, aminoferrocene (NH2-Fc). This coating enhances stability via electroactivity and reduces nonspecific binding, as demonstrated through cyclic voltammetry. Our approach enables real-time glucose detection via chronoamperometry with a calculated linear range of 0.5 to 20 mM and a 1 mM detection limit. Validated with plasma and saliva, this platform shows promise for robust metabolite detection in clinical and research contexts. This versatile platform can be applied to accurately monitor a wide range of metabolites in various biological matrices, improving patient outcomes.
Collapse
Affiliation(s)
- Sajjad Janfaza
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA (N.R.S.); (P.J.)
| | - Nandhinee Radha Shanmugam
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA (N.R.S.); (P.J.)
| | - Pawan Jolly
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA (N.R.S.); (P.J.)
| | - Prashanthi Kovur
- Department of Biological Sciences, University of Alberta, Edmonton, AB T6G 2E8, Canada; (P.K.); (U.S.); (S.M.); (D.W.)
| | - Upasana Singh
- Department of Biological Sciences, University of Alberta, Edmonton, AB T6G 2E8, Canada; (P.K.); (U.S.); (S.M.); (D.W.)
| | - Scott Mackay
- Department of Biological Sciences, University of Alberta, Edmonton, AB T6G 2E8, Canada; (P.K.); (U.S.); (S.M.); (D.W.)
| | - David Wishart
- Department of Biological Sciences, University of Alberta, Edmonton, AB T6G 2E8, Canada; (P.K.); (U.S.); (S.M.); (D.W.)
| | - Donald E. Ingber
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA (N.R.S.); (P.J.)
- Harvard John A. Paulson School of Engineering and Applied Sciences, Cambridge, MA 02139, USA
- Department of Pathology, Harvard Medical School, Boston, MA 02115, USA
- Vascular Biology Program, Department of Surgery, Boston Children’s Hospital, Boston, MA 02115, USA
| |
Collapse
|
4
|
Silina YE. One-step electrodeposited hybrid nanofilms in amperometric biosensor development. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2424-2443. [PMID: 38592715 DOI: 10.1039/d4ay00290c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/10/2024]
Abstract
This review summarizes recent developments in amperometric biosensors, based on one-step electrodeposited organic-inorganic hybrid layers, used for analysis of low molecular weight compounds. The factors affecting self-assembly of one-step electrodeposited films, methods for verifying their composition, advantages, limitations and approaches affecting the electroanalytical performance of amperometric biosensors based on organic-inorganic hybrid layers were systemized. Moreover, issues related to the formation of one-step organic-inorganic hybrid functional layers with different structures in biosensors produced under the same electrodeposition parameters are discussed. The systemized dependencies can support the preliminary choice of functional sensing layers with architectures tuned for specific biotechnology and life science applications. Finally, the capabilities of one-step electrodeposition of organic-inorganic hybrid functional films beyond amperometric biosensors were highlighted.
Collapse
Affiliation(s)
- Yuliya E Silina
- Institute of Biochemistry, Saarland University, Campus B 2.2, Room 317, Saarbrücken, Germany.
| |
Collapse
|
5
|
Liu W, Lewis SE, di Lorenzo M, Squires AM. Development of Redox-Active Lyotropic Lipid Cubic Phases for Biosensing Platforms. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:170-178. [PMID: 38113389 PMCID: PMC10786026 DOI: 10.1021/acs.langmuir.3c02307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 11/15/2023] [Accepted: 11/16/2023] [Indexed: 12/21/2023]
Abstract
Enzyme-based electrochemical biosensors play an important role in point-of-care diagnostics for personalized medicine. For such devices, lipid cubic phases (LCP) represent an attractive method to immobilize enzymes onto conductive surfaces with no need for chemical linking. However, research has been held back by the lack of effective strategies to stably co-immobilize enzymes with a redox shuttle that enhances the electrical connection between the enzyme redox center and the electrode. In this study, we show that a monoolein (MO) LCP system doped with an amphiphilic redox mediator (ferrocenylmethyl)dodecyldimethylammonium bromide (Fc12) can be used for enzyme immobilization to generate an effective biosensing platform. Small-angle X-ray scattering (SAXS) showed that MO LCP can incorporate Fc12 while maintaining the Pn3m symmetry morphology. Cyclic voltammograms of Fc12/MO showed quasi-reversible behavior, which implied that Fc12 was able to freely diffuse in the lipid membrane of LCP with a diffusion coefficient of 1.9 ± 0.2 × 10-8 cm2 s-1 at room temperature. Glucose oxidase (GOx) was then chosen as a model enzyme and incorporated into 0.2%Fc12/MO to evaluate the activity of the platform. GOx hosted in 0.2%Fc12/MO followed Michaelis-Menten kinetics toward glucose with a KM and Imax of 8.9 ± 0.5 mM and 1.4 ± 0.2 μA, respectively, and a linearity range of 2-17 mM glucose. Our results therefore demonstrate that GOx immobilized onto 0.2% Fc12/MO is a suitable platform for the electrochemical detection of glucose.
Collapse
Affiliation(s)
- Wanli Liu
- Department
of Chemistry, University of Bath, Bath BA2 7AY, U.K.
| | - Simon E. Lewis
- Department
of Chemistry, University of Bath, Bath BA2 7AY, U.K.
| | - Mirella di Lorenzo
- Department
of Chemical Engineering, University of Bath, Bath BA2 7AY, U.K.
| | - Adam M. Squires
- Department
of Chemistry, University of Bath, Bath BA2 7AY, U.K.
| |
Collapse
|
6
|
Sakalauskiene L, Brasiunas B, Popov A, Kausaite-Minkstimiene A, Ramanaviciene A. The Development of Reagentless Amperometric Glucose Biosensor Based on Gold Nanostructures, Prussian Blue and Glucose Oxidase. BIOSENSORS 2023; 13:942. [PMID: 37887135 PMCID: PMC10605372 DOI: 10.3390/bios13100942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 10/13/2023] [Accepted: 10/16/2023] [Indexed: 10/28/2023]
Abstract
Precise blood glucose detection plays a crucial role in diagnosing and medicating diabetes, in addition to aiding diabetic patients in effectively managing their condition. In this research, a first-generation reagentless amperometric glucose biosensor was developed by combining the graphite rod (GR) electrode modification by gold nanostructures (AuNS) and Prussian blue (PB) with glucose oxidase (GOx)-an enzyme that can oxidize glucose and produce H2O2. Firstly, AuNS was electrochemically deposited on the GR electrode (AuNS/GR), and then PB was electrochemically synthesized on the AuNS/GR electrode (PB/AuNS/GR). Finally, GOx was immobilized over the PB/AuNS nanocomposite with the assistance of Nafion (Nf) (Nf-GOx/PB/AuNS/GR). An application of PB in the design of a glucose biosensor enables an easy electrochemical reduction and, thus, the determination of the H2O2 produced during the GOx-catalyzed oxidation of glucose in the sample at a low operation potential of -0.05 V vs. Ag/AgCl/KCl3 mol L-1. In addition, AuNS increased the electrochemically active surface area, improved the GOx immobilization and ensured a higher analytical signal. The developed glucose biosensor based on the Nf-GOx/PB/AuNS/GR electrode exhibited a wide linear range, from 0.025 to 1 mmol L-1 of glucose, with a 0.0088 mmol L-1 limit of detection, good repeatability and high selectivity over electroactive interfering substances. The developed biosensor is convenient for the determination of glucose in the physiological environment.
Collapse
Affiliation(s)
- Laura Sakalauskiene
- NanoTechnas—Center of Nanotechnology and Materials Science, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT-03225 Vilnius, Lithuania; (L.S.); (B.B.); (A.P.)
| | - Benediktas Brasiunas
- NanoTechnas—Center of Nanotechnology and Materials Science, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT-03225 Vilnius, Lithuania; (L.S.); (B.B.); (A.P.)
| | - Anton Popov
- NanoTechnas—Center of Nanotechnology and Materials Science, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT-03225 Vilnius, Lithuania; (L.S.); (B.B.); (A.P.)
- Department of Immunology, State Research Institute Centre for Innovative Medicine, Santariskiu St. 5, LT-08406 Vilnius, Lithuania
| | - Asta Kausaite-Minkstimiene
- NanoTechnas—Center of Nanotechnology and Materials Science, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT-03225 Vilnius, Lithuania; (L.S.); (B.B.); (A.P.)
- Department of Immunology, State Research Institute Centre for Innovative Medicine, Santariskiu St. 5, LT-08406 Vilnius, Lithuania
| | - Almira Ramanaviciene
- NanoTechnas—Center of Nanotechnology and Materials Science, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT-03225 Vilnius, Lithuania; (L.S.); (B.B.); (A.P.)
- Department of Immunology, State Research Institute Centre for Innovative Medicine, Santariskiu St. 5, LT-08406 Vilnius, Lithuania
| |
Collapse
|
7
|
Sun G, Wei X, Zhang D, Huang L, Liu H, Fang H. Immobilization of Enzyme Electrochemical Biosensors and Their Application to Food Bioprocess Monitoring. BIOSENSORS 2023; 13:886. [PMID: 37754120 PMCID: PMC10526424 DOI: 10.3390/bios13090886] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 09/07/2023] [Accepted: 09/11/2023] [Indexed: 09/28/2023]
Abstract
Electrochemical biosensors based on immobilized enzymes are among the most popular and commercially successful biosensors. The literature in this field suggests that modification of electrodes with nanomaterials is an excellent method for enzyme immobilization, which can greatly improve the stability and sensitivity of the sensor. However, the poor stability, weak reproducibility, and limited lifetime of the enzyme itself still limit the requirements for the development of enzyme electrochemical biosensors for food production process monitoring. Therefore, constructing sensing technologies based on enzyme electrochemical biosensors remains a great challenge. This article outlines the construction principles of four generations of enzyme electrochemical biosensors and discusses the applications of single-enzyme systems, multi-enzyme systems, and nano-enzyme systems developed based on these principles. The article further describes methods to improve enzyme immobilization by combining different types of nanomaterials such as metals and their oxides, graphene-related materials, metal-organic frameworks, carbon nanotubes, and conducting polymers. In addition, the article highlights the challenges and future trends of enzyme electrochemical biosensors, providing theoretical support and future perspectives for further research and development of high-performance enzyme chemical biosensors.
Collapse
Affiliation(s)
- Ganchao Sun
- School of Food Science and Engineering, Ningxia University, Yinchuan 750021, China; (G.S.); (X.W.)
| | - Xiaobo Wei
- School of Food Science and Engineering, Ningxia University, Yinchuan 750021, China; (G.S.); (X.W.)
| | - Dianping Zhang
- School of Mechanical Engineering, Ningxia University, Yinchuan 750021, China;
| | - Liben Huang
- Huichuan Technology (Zhuhai) Co., Ltd., Zhuhai 519060, China;
| | - Huiyan Liu
- School of Food Science and Engineering, Ningxia University, Yinchuan 750021, China; (G.S.); (X.W.)
| | - Haitian Fang
- School of Food Science and Engineering, Ningxia University, Yinchuan 750021, China; (G.S.); (X.W.)
| |
Collapse
|
8
|
Wijayanti SD, Tsvik L, Haltrich D. Recent Advances in Electrochemical Enzyme-Based Biosensors for Food and Beverage Analysis. Foods 2023; 12:3355. [PMID: 37761066 PMCID: PMC10529900 DOI: 10.3390/foods12183355] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 08/28/2023] [Accepted: 09/04/2023] [Indexed: 09/29/2023] Open
Abstract
Food analysis and control are crucial aspects in food research and production in order to ensure quality and safety of food products. Electrochemical biosensors based on enzymes as the bioreceptors are emerging as promising tools for food analysis because of their high selectivity and sensitivity, short analysis time, and high-cost effectiveness in comparison to conventional methods. This review provides the readers with an overview of various electrochemical enzyme-based biosensors in food analysis, focusing on enzymes used for different applications in the analysis of sugars, alcohols, amino acids and amines, and organic acids, as well as mycotoxins and chemical contaminants. In addition, strategies to improve the performance of enzyme-based biosensors that have been reported over the last five years will be discussed. The challenges and future outlooks for the food sector are also presented.
Collapse
Affiliation(s)
- Sudarma Dita Wijayanti
- Laboratory of Food Biotechnology, Department of Food Science and Technology, University of Natural Resources and Life Sciences Vienna, Muthgasse 11, A-1190 Wien, Austria; (S.D.W.)
- Department of Food Science and Biotechnology, Brawijaya University, Malang 65145, Indonesia
| | - Lidiia Tsvik
- Laboratory of Food Biotechnology, Department of Food Science and Technology, University of Natural Resources and Life Sciences Vienna, Muthgasse 11, A-1190 Wien, Austria; (S.D.W.)
| | - Dietmar Haltrich
- Laboratory of Food Biotechnology, Department of Food Science and Technology, University of Natural Resources and Life Sciences Vienna, Muthgasse 11, A-1190 Wien, Austria; (S.D.W.)
| |
Collapse
|
9
|
Gatou MA, Vagena IA, Pippa N, Gazouli M, Pavlatou EA, Lagopati N. The Use of Crystalline Carbon-Based Nanomaterials (CBNs) in Various Biomedical Applications. CRYSTALS 2023; 13:1236. [DOI: 10.3390/cryst13081236] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/11/2023]
Abstract
This review study aims to present, in a condensed manner, the significance of the use of crystalline carbon-based nanomaterials in biomedical applications. Crystalline carbon-based nanomaterials, encompassing graphene, graphene oxide, reduced graphene oxide, carbon nanotubes, and graphene quantum dots, have emerged as promising materials for the development of medical devices in various biomedical applications. These materials possess inorganic semiconducting attributes combined with organic π-π stacking features, allowing them to efficiently interact with biomolecules and present enhanced light responses. By harnessing these unique properties, carbon-based nanomaterials offer promising opportunities for future advancements in biomedicine. Recent studies have focused on the development of these nanomaterials for targeted drug delivery, cancer treatment, and biosensors. The conjugation and modification of carbon-based nanomaterials have led to significant advancements in a plethora of therapies and have addressed limitations in preclinical biomedical applications. Furthermore, the wide-ranging therapeutic advantages of carbon nanotubes have been thoroughly examined in the context of biomedical applications.
Collapse
Affiliation(s)
- Maria-Anna Gatou
- Laboratory of General Chemistry, School of Chemical Engineering, National Technical University of Athens, Zografou Campus, 15772 Athens, Greece
| | - Ioanna-Aglaia Vagena
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
| | - Natassa Pippa
- Section of Pharmaceutical Technology, Department of Pharmacy, School of Health Sciences, National and Kapodistrian University of Athens, 15771 Athens, Greece
| | - Maria Gazouli
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- School of Science and Technology, Hellenic Open University, 26335 Patra, Greece
| | - Evangelia A. Pavlatou
- Laboratory of General Chemistry, School of Chemical Engineering, National Technical University of Athens, Zografou Campus, 15772 Athens, Greece
| | - Nefeli Lagopati
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- Biomedical Research Foundation, Academy of Athens, 11527 Athens, Greece
| |
Collapse
|
10
|
Shi CY, Zhan YF, Liu Y, Zhang ZP, Shen XY, Wu CK, Bai ZY, Zhang ZA, Wang J. Hydrophobic effects enhance xylooligosaccharides production from mulberry branch using xylanase-methacrylate conjugate-catalyzed hydrolysis. Biochem Eng J 2023. [DOI: 10.1016/j.bej.2023.108851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
|
11
|
Hefnawy MA, Fadlallah SA, El-Sherif RM, Medany SS. Competition between enzymatic and non-enzymatic electrochemical determination of cholesterol. J Electroanal Chem (Lausanne) 2023; 930:117169. [DOI: 10.1016/j.jelechem.2023.117169] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
12
|
Bollella P. Enzyme-based amperometric biosensors: 60 years later … Quo Vadis? Anal Chim Acta 2022; 1234:340517. [DOI: 10.1016/j.aca.2022.340517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 10/09/2022] [Accepted: 10/11/2022] [Indexed: 11/01/2022]
|
13
|
Rusu AG, Chiriac AP, Nita LE, Balan V, Serban AM, Croitoriu A. Synthesis and Comparative Studies of Glucose Oxidase Immobilized on Fe 3O 4 Magnetic Nanoparticles Using Different Coupling Agents. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:2445. [PMID: 35889669 PMCID: PMC9318457 DOI: 10.3390/nano12142445] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 07/12/2022] [Accepted: 07/15/2022] [Indexed: 11/30/2022]
Abstract
Squaric acid (SA) is a compound with potential to crosslink biomacromolecules. Although SA has become over the last years a well-known crosslinking agent as a result of its good biocompatibility, glutaraldehyde (GA), a compound with proven cytotoxicity is still one of the most used crosslinkers to develop nanomaterials. In this regard, the novelty of the present study consists in determining whether it may be possible to substitute GA with a new bifunctional and biocompatible compound, such as SA, in the process of enzyme immobilization on the surface of magnetic nanoparticles (MNPs). Thus, a direct comparison between SA- and GA-functionalized magnetic nanoparticles was realized in terms of physico-chemical properties and ability to immobilize catalytic enzymes. The optimal conditions of the synthesis of the two types of GOx-immobilized MNPs were described, thus emphasizing the difference between the two reagents. Scanning Electron Microscopy and Dynamic Light Scattering were used for size, shape and colloidal stability characterization of the pristine MNPs and of those coupled with GOx. Binding of GOx to MNPs by using GA or SA was confirmed by FT-IR spectroscopy. The stability of the immobilized and free enzyme was investigated by measuring the enzymatic activity. The study confirmed that the resulting activity of the immobilized enzyme and the optimization of enzyme immobilization depended on the type of reagent used and duration of the process. The catalytic performance of immobilized enzyme was tested, revealing that the long-term colloidal stability of SA-functionalized MNPs was superior to those prepared with GA. In conclusion, the SA-functionalized bioconjugates have a better potential as compared to the GA-modified nanosystems to be regarded as catalytic nanodevices for biomedical purposes such as biosensors.
Collapse
Affiliation(s)
- Alina Gabriela Rusu
- Natural Polymers, Bioactive and Biocompatible Materials Department, Petru Poni Institute of Macromolecular Chemistry, 41A Gr. Ghica–Voda Alley, 700487 Iasi, Romania; (A.P.C.); (L.E.N.); (A.M.S.); (A.C.)
| | - Aurica P. Chiriac
- Natural Polymers, Bioactive and Biocompatible Materials Department, Petru Poni Institute of Macromolecular Chemistry, 41A Gr. Ghica–Voda Alley, 700487 Iasi, Romania; (A.P.C.); (L.E.N.); (A.M.S.); (A.C.)
| | - Loredana Elena Nita
- Natural Polymers, Bioactive and Biocompatible Materials Department, Petru Poni Institute of Macromolecular Chemistry, 41A Gr. Ghica–Voda Alley, 700487 Iasi, Romania; (A.P.C.); (L.E.N.); (A.M.S.); (A.C.)
| | - Vera Balan
- Faculty of Medical Bioengineering, Grigore T. Popa University of Medicine and Pharmacy of Iasi, 700115 Iasi, Romania;
| | - Alexandru Mihail Serban
- Natural Polymers, Bioactive and Biocompatible Materials Department, Petru Poni Institute of Macromolecular Chemistry, 41A Gr. Ghica–Voda Alley, 700487 Iasi, Romania; (A.P.C.); (L.E.N.); (A.M.S.); (A.C.)
| | - Alexandra Croitoriu
- Natural Polymers, Bioactive and Biocompatible Materials Department, Petru Poni Institute of Macromolecular Chemistry, 41A Gr. Ghica–Voda Alley, 700487 Iasi, Romania; (A.P.C.); (L.E.N.); (A.M.S.); (A.C.)
| |
Collapse
|
14
|
Jayakumar K, Reichhart TM, Schulz C, Ludwig R, Felice AK, Leech D. An Oxygen Insensitive Amperometric Glucose Biosensor Based on an Engineered Cellobiose Dehydrogenase: Direct Versus Mediated Electron Transfer Responses. ChemElectroChem 2022. [DOI: 10.1002/celc.202200418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
| | | | | | - Roland Ludwig
- BOKU: Universitat fur Bodenkultur Wien Food Science and Technology IRELAND
| | | | - Donal Leech
- National University of Ireland Galway School of Chemistry & Ryan Institute University Rd Galway IRELAND
| |
Collapse
|
15
|
Dai B, Zhou R, Ping J, Ying Y, Xie L. Recent advances in carbon nanotube-based biosensors for biomolecular detection. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
16
|
Osuna V, Vega-Rios A, Zaragoza-Contreras EA, Estrada-Moreno IA, Dominguez RB. Progress of Polyaniline Glucose Sensors for Diabetes Mellitus Management Utilizing Enzymatic and Non-Enzymatic Detection. BIOSENSORS 2022; 12:137. [PMID: 35323407 PMCID: PMC8946794 DOI: 10.3390/bios12030137] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 02/17/2022] [Accepted: 02/18/2022] [Indexed: 05/21/2023]
Abstract
Glucose measurement is a fundamental tool in the daily care of Diabetes Mellitus (DM) patients and healthcare professionals. While there is an established market for glucose sensors, the rising number of DM cases has promoted intensive research to provide accurate systems for glucose monitoring. Polyaniline (PAni) is a conductive polymer with a linear conjugated backbone with sequences of single C-C and double C=C bonds. This unique structure produces attractive features for the design of sensing systems such as conductivity, biocompatibility, environmental stability, tunable electrochemical properties, and antibacterial activity. PAni-based glucose sensors (PBGS) were actively developed in past years, using either enzymatic or non-enzymatic principles. In these devices, PAni played roles as a conductive material for electron transfer, biocompatible matrix for enzymatic immobilization, or sensitive layer for detection. In this review, we covered the development of PBGS from 2015 to the present, and it is not even exhaustive; it provides an overview of advances and achievements for enzymatic and non-enzymatic PBGB PBGS for self-monitoring and continuous blood glucose monitoring. Additionally, the limitations of PBGB PBGS to advance into robust and stable technology and the challenges associated with their implementation are presented and discussed.
Collapse
Affiliation(s)
- Velia Osuna
- CONACYT-CIMAV, SC, Av. Miguel de Cervantes #120, Chihuahua C.P. 31136, Mexico; (V.O.); (I.A.E.-M.)
| | - Alejandro Vega-Rios
- Centro de Investigación en Materiales Avanzados, SC, Av. Miguel de Cervantes #120, Chihuahua C.P. 31136, Mexico; (A.V.-R.); (E.A.Z.-C.)
| | - Erasto Armando Zaragoza-Contreras
- Centro de Investigación en Materiales Avanzados, SC, Av. Miguel de Cervantes #120, Chihuahua C.P. 31136, Mexico; (A.V.-R.); (E.A.Z.-C.)
| | | | - Rocio B. Dominguez
- CONACYT-CIMAV, SC, Av. Miguel de Cervantes #120, Chihuahua C.P. 31136, Mexico; (V.O.); (I.A.E.-M.)
| |
Collapse
|
17
|
The development of alginate-based amperometric nanoreactors for biochemical profiling of living yeast cells. Bioelectrochemistry 2022; 145:108082. [DOI: 10.1016/j.bioelechem.2022.108082] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 01/25/2022] [Accepted: 01/28/2022] [Indexed: 12/27/2022]
|
18
|
García-Beleño J, Rodríguez de San Miguel E. Optimization of Cr(III) transport in a polymer inclusion membrane system through experimental design strategies. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-021-02031-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
19
|
Alvarado-Ramírez L, Rostro-Alanis M, Rodríguez-Rodríguez J, Sosa-Hernández JE, Melchor-Martínez EM, Iqbal HMN, Parra-Saldívar R. Enzyme (Single and Multiple) and Nanozyme Biosensors: Recent Developments and Their Novel Applications in the Water-Food-Health Nexus. BIOSENSORS 2021; 11:410. [PMID: 34821626 PMCID: PMC8615953 DOI: 10.3390/bios11110410] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 09/17/2021] [Accepted: 09/22/2021] [Indexed: 02/05/2023]
Abstract
The use of sensors in critical areas for human development such as water, food, and health has increased in recent decades. When the sensor uses biological recognition, it is known as a biosensor. Nowadays, the development of biosensors has been increased due to the need for reliable, fast, and sensitive techniques for the detection of multiple analytes. In recent years, with the advancement in nanotechnology within biocatalysis, enzyme-based biosensors have been emerging as reliable, sensitive, and selectively tools. A wide variety of enzyme biosensors has been developed by detecting multiple analytes. In this way, together with technological advances in areas such as biotechnology and materials sciences, different modalities of biosensors have been developed, such as bi-enzymatic biosensors and nanozyme biosensors. Furthermore, the use of more than one enzyme within the same detection system leads to bi-enzymatic biosensors or multi-enzyme sensors. The development and synthesis of new materials with enzyme-like properties have been growing, giving rise to nanozymes, considered a promising tool in the biosensor field due to their multiple advantages. In this review, general views and a comparison describing the advantages and disadvantages of each enzyme-based biosensor modality, their possible trends and the principal reported applications will be presented.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Roberto Parra-Saldívar
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey 64849, Mexico; (L.A.-R.); (M.R.-A.); (J.R.-R.); (J.E.S.-H.); (E.M.M.-M.); (H.M.N.I.)
| |
Collapse
|