Wozniak KT, Manning ZA, Huang R, Cox S, Butler SC, Ferlo S, Zheleznyak L, Xu L, Ellis JD, Huxlin KR, Knox WH. Multiphoton scaling of femtosecond laser-induced refractive index change (LIRIC) in hydrogels and rabbit cornea. BIOMEDICAL OPTICS EXPRESS 2024; 15:6242-6258. [PMID: 39553877 PMCID: PMC11563327 DOI: 10.1364/boe.537705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Revised: 09/13/2024] [Accepted: 09/23/2024] [Indexed: 11/19/2024]
Abstract
To find optimal conditions for performing laser induced refractive index change (LIRIC) in living eyes with both safety and efficacy, we investigated multiphoton excitation scaling of this procedure in hydrogel and excised corneal tissue. Three distinct wavelength modalities were examined: high-repetition-rate (HRR) and low-repetition-rate (LRR) 405 nm systems, as well as 800 nm and 1035 nm systems, whose LIRIC-inducing properties are described for the first time. Of all the systems, LRR 405 nm-LIRIC was able to produce the highest phase shifts at the lowest average laser powers. Relative merits and drawbacks to each modality are discussed as they relate to future efforts towards LIRIC-based refractive error correction in humans.
Collapse
Affiliation(s)
- Kaitlin T. Wozniak
- The Flaum Eye Institute, University of Rochester, Rochester, NY 14642, USA
- The Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
| | - Zachary A. Manning
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
| | - Ruiting Huang
- The Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
| | - Steven Cox
- Clerio Vision Inc., Rochester, NY 14618, USA
| | | | | | - Len Zheleznyak
- The Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
- Clerio Vision Inc., Rochester, NY 14618, USA
| | - Lisen Xu
- Clerio Vision Inc., Rochester, NY 14618, USA
| | - Jonathan D. Ellis
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
| | - Krystel R. Huxlin
- The Flaum Eye Institute, University of Rochester, Rochester, NY 14642, USA
- The Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
| | - Wayne H. Knox
- The Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
| |
Collapse
|
2
|
Huang R, Yu D, Savage D, Wozniak K, Zheleznyak L, Knox WH, Huxlin KR. Blue-LIRIC in the rabbit cornea: efficacy, tissue effects, and repetition rate scaling. BIOMEDICAL OPTICS EXPRESS 2022; 13:2346-2363. [PMID: 35519279 PMCID: PMC9045900 DOI: 10.1364/boe.448286] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 01/20/2022] [Accepted: 03/10/2022] [Indexed: 06/14/2023]
Abstract
Laser-induced refractive index change (LIRIC) is being developed as a non-invasive way to alter optical properties of transparent, ophthalmic materials including corneas ex vivo and in vivo. This study examined the optical and biological effects of blue-LIRIC (wavelengths 400-405 nm) of ex-vivo rabbit corneas. Following LIRIC treatment at low and high repetition rates (8.3 MHz and 80 MHz, respectively), we interferometrically measured optical phase change, obtained transmission electron microscopy (TEM) micrographs, and stained histological sections with collagen hybridizing peptides (CHP) to assess the structural and organizational changes caused by LIRIC at different repetition rates. Finally, we performed power and scan speed scaling experiments at three different repetition rates (1 MHz, 8.3 MHz, and 80 MHz) to study their impact on LIRIC efficacy. Histologic co-localization of CHP and LIRIC-generated green autofluorescence signals suggested that collagen denaturation had occurred in the laser-irradiated region. TEM imaging showed different ultrastructural modifications for low and high repetition rate writing, with discrete homogenization of collagen fibrils at 80 MHz, as opposed to contiguous homogenization at 8.3 MHz. Overall, this study confirmed that LIRIC efficacy can be dramatically increased, while still avoiding tissue ablation, by lowering the repetition rate from 80 MHz to 8.3 MHz. Modeling suggests that this is due to a higher, single-pulse, energy density deposition at given laser powers during 8.3 MHz LIRIC.
Collapse
Affiliation(s)
- Ruiting Huang
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
| | - Dan Yu
- Materials Science Program, University of Rochester, Rochester, NY 14627, USA
| | - Daniel Savage
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Flaum Eye Institute, University of Rochester, Rochester, NY 14627, USA
| | - Kaitlin Wozniak
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Flaum Eye Institute, University of Rochester, Rochester, NY 14627, USA
| | | | - Wayne H. Knox
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Materials Science Program, University of Rochester, Rochester, NY 14627, USA
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
| | - Krystel R. Huxlin
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Flaum Eye Institute, University of Rochester, Rochester, NY 14627, USA
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
| |
Collapse
|
3
|
Abstract
Presbyopia affects 1.8 billion people worldwide. This reduction in distance corrected near visual acuity impacts quality of life, which prompts patients to seek treatment. Presbyopia is an early manifestation of the "crystalline lens optical dysfunction through aging," or dysfunctional lens syndrome, and appropriate management of presbyopia is dependent on coexisting factors such as increased higher order aberrations, reduced contrast sensitivity, light scatter, and lenticular opacification. This review of published literature (PubMed and MEDLINE) is presented in narrative format and discusses medical and surgical treatments available to patients who experience presbyopia, while highlighting future therapies. Numerous strategies exist for the management of presbyopia. These strategies include pharmacological therapy, glasses and contact lenses, corneal, scleral, and lenticular procedures. This article discusses the role of several new and existing presbyopia treatments, as well as which patients are candidates for these novel therapies. Although no single treatment is ideal for all patients with presbyopia, new medical and surgical strategies increase the number of options available when addressing different stages of presbyopia and dysfunctional lens syndrome. [J Refract Surg. 2021;37(6 Suppl):S28-S34.].
Collapse
|
4
|
McDonald MB, Mychajlyszyn A, Mychajlyszyn D, Klyce SD. Advances in Corneal Surgical and Pharmacological Approaches to the Treatment of Presbyopia. J Refract Surg 2021; 37:S20-S27. [PMID: 34170764 DOI: 10.3928/1081597x-20210408-04] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The purpose of this article is to review the current status of presbyopia amelioration with surgical and pharmacologic procedures that partially compensate for loss of accommodation in advance of cataract surgery and lens replacement. Over the last few years, several corneal surgical and topical pharmacological approaches for the treatment of presbyopia have been introduced to the marketplace or are in the developmental pipeline. The approaches vary in invasiveness, duration of effect, reversibility, risk/benefit ratio, and clinical results. The advantages and disadvantages for each are discussed. Corneal surgical interventions aim to provide improved near and intermediate vision in patients with presbyopia through refractive means that extend ocular depth of focus through shape modification. The use of miotic drops or corneal lamellar implants extend depth of focus with the "pinhole" aperture size reduction effect. Unlike in adults younger than 40 years, the refractive status of the patient with presbyopia is not stable. Hence, procedures that provide a permanent refractive change may not provide long-term full correction; eye drops or other treatments that are self-reversing in time or are easily reversible may be used as needed. On the horizon, procedures are being explored that may add years of functional lens accommodation by preserving the deformable gel properties of the lens. [J Refract Surg. 2021;37(6 Suppl):S20-S27.].
Collapse
|
5
|
Temporal evolution of the biological response to laser-induced refractive index change (LIRIC) in rabbit corneas. Exp Eye Res 2021; 207:108579. [PMID: 33864783 DOI: 10.1016/j.exer.2021.108579] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 03/22/2021] [Accepted: 04/10/2021] [Indexed: 02/06/2023]
Abstract
Laser-induced refractive index change (LIRIC) is a new, non-incisional, non-ablative, femtosecond photo-modification technique being developed for vision correction in humans. Prior, exvivo studies showed intra-tissue refractive index change to induce minimal cell death, restricted to the laser focal zone in the corneal stroma, and with no observable damage to the epithelium or endothelium. Here, we used live rabbits to ascertain longer-term consequences of LIRIC in vivo. Specifically, we assessed cell death, fibrosis, corneal nerve distribution, endothelial cell density, and corneal structure for up to 3 months after LIRIC. A +2.5 D gradient-index LIRIC Fresnel lens was inscribed inside 20 applanated corneas of Dutch Belted rabbits, over a circular region of the mid-stroma measuring 4.5 mm in diameter. Twelve additional rabbit eyes were used as applanation-only controls to differentiate the effects of laser treatment and suction applanation on biological and structural parameters. In vivo optical measurements were performed pre-operatively, then immediately, 2, 4, and 12 weeks after the procedure, to measure endothelial cell density and changes in corneal structure. Groups of four rabbits were sacrificed at 4 hours, 2, 4, and 12 weeks after LIRIC for histological determinations; the TUNEL assay was used to evaluate cell death, H&E staining was used to assess inflammatory infiltration, and immunostaining for α-smooth muscle actin (α-SMA) and βIII tubulin (Tuj-1) was performed to assess myofibroblast differentiation and corneal nerve distribution, respectively. Consistent with prior ex vivo data, only minimal cell death was observed in the laser focal zone, with TUNEL-positive cells restricted to the stromal region of refractive index change 4 h after LIRIC. No TUNEL-positive cells were evident anywhere in the cornea 2, 4, or 12 weeks after LIRIC. Applanation-only corneas were completely TUNEL-negative. Neither LIRIC-treated nor applanation-only eyes exhibited α-SMA-positive staining or altered corneal nerve distributions at any of the time points examined. In vivo confocal imaging revealed normal endothelial cell densities in all eyes (whether LIRIC-treated or applanation-only) at all time points. Optical coherence tomography showed suction applanation to cause a temporary decrease in central corneal thickness, which returned to normal within 4 h. Corneas into which LIRIC Fresnel lenses were written while applanated did not undergo major structural or shape changes beyond the temporary thinning already described for suction applanation. The present findings suggest that LIRIC patterns, which generated a clinically-relevant refractive correction in the mid-stromal region of live rabbit corneas, induced little-to-no disruption to corneal structure and biology for 3 months after the procedure. This affirms the relative safety of LIRIC and predicts that compared to traditional laser vision correction surgeries, common post-operative complications such as dry eye, haze, or patient discomfort may be entirely avoided.
Collapse
|
6
|
Sioufi K, Zheleznyak L, MacRae S, Rocha KM. Femtosecond Lasers in Cornea & Refractive Surgery. Exp Eye Res 2021; 205:108477. [PMID: 33516763 DOI: 10.1016/j.exer.2021.108477] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 01/20/2021] [Accepted: 01/22/2021] [Indexed: 11/18/2022]
Abstract
Since the introduction of femtosecond laser (FS) systems for corneal flap creation in laser-assisted in-situ keratomileusis there have been numerous applications for FS laser in corneal surgery. This manuscript details the utility of FS lasers in corneal surgical procedures including refractive laser surgeries, intracorneal ring segment tunnels, presbyopic treatments, and FS-assisted keratoplasty. We also review the role of FS lasers in diagnostic procedures such as two photon excitation fluorescence and second harmonic generation.
Collapse
Affiliation(s)
- Kareem Sioufi
- Storm Eye Institute, Medical University of South Carolina, Charleston, SC, USA
| | | | - Scott MacRae
- Flaum Eye Institute and the Institute of Optics, University of Rochester, Rochester, NY, USA
| | - Karolinne M Rocha
- Storm Eye Institute, Medical University of South Carolina, Charleston, SC, USA.
| |
Collapse
|
7
|
Yu D, Brown EB, Huxlin KR, Knox WH. Tissue effects of intra-tissue refractive index shaping (IRIS): insights from two-photon autofluorescence and second harmonic generation microscopy. BIOMEDICAL OPTICS EXPRESS 2019; 10:855-867. [PMID: 30800519 PMCID: PMC6377903 DOI: 10.1364/boe.10.000855] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Revised: 12/29/2018] [Accepted: 01/02/2019] [Indexed: 05/05/2023]
Abstract
Intra-tissue refractive index shaping (IRIS) is a novel, non-ablative form of vision correction by which femtosecond laser pulses are tightly focused into ocular tissues to induce localized refractive index (RI) change via nonlinear absorption. Here, we examined the effects of Blue-IRIS on corneal microstructure to gain insights into underlying mechanisms. Three-layer grating patterns were inscribed with IRIS ~180 µm below the epithelial surface of ex vivo rabbit globes using a 400 nm femtosecond laser. Keeping laser power constant at 82 mW in the focal volume, multiple patterns were written at different scan speeds. The largest RI change induced in this study was + 0.011 at 20 mm/s. After measuring the phase change profile of each inscribed pattern, two-photon excited autofluorescence (TPEF) and second harmonic generation (SHG) microscopy were used to quantify changes in stromal structure. While TPEF increased significantly with induced RI change, there was a noticeable suppression of SHG signal in IRIS treated regions. We posit that enhancement of TPEF was due to the formation of new fluorophores, while decreases in SHG were most likely due to degradation of collagen triple helices. All in all, the changes observed suggest that IRIS works by inducing a localized, photochemical change in collagen structure.
Collapse
Affiliation(s)
- Dan Yu
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Materials Science Program, University of Rochester, Rochester, NY 14627, USA
| | - Edward B. Brown
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
| | - Krystel R. Huxlin
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Flaum Eye Institute, University of Rochester, Rochester, NY 14627, USA
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
| | - Wayne H. Knox
- The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
- Materials Science Program, University of Rochester, Rochester, NY 14627, USA
- Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
| |
Collapse
|