1
|
Kamel AH, Abd-Rabboh HSM, Bajaber MA. Non-enzymatic paper-based analytical device for direct potentiometric detection of urine creatinine. Mikrochim Acta 2024; 191:128. [PMID: 38334814 DOI: 10.1007/s00604-024-06203-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Accepted: 01/08/2024] [Indexed: 02/10/2024]
Abstract
A paper-based analytical device (PAD) with an integrated composite electrode has been designed and fabricated for non-enzymatic creatinine sensing. Reduced graphene oxide (rGO) was employed to modify the PAD so that it could function as a solid-contact transducer. A new macrocyclic pyrido-hexapeptide derivative was made and used as a special ionophore in the creatinine membrane sensor. The synthesized PAD showed a detection limit of 1.0 µM (S/N = 3) and a potentiometric response towards creatinine throughout a log-linear range of 2.0 µM-10 mM (R2 = 0.9998). The sensor shows significant selectivity for a few related substances, including ephedrine, codeine, ketamine, caffeine, urea, urate, carbinoxamine, and dextromethorphan. It has been established that the testing method is appropriate for the direct potentiometric detection of creatinine in a variety of human urine sample types. When an indicating electrode and a reference electrode are put on the same flexible disposable, this lets applications with a small sample volume be done. For point-of-care creatinine measurement, the developed paper-based analytical equipment is a good choice because it is affordable, easily accessible, and self-pumping (especially when combined with potentiometric detection).
Collapse
Affiliation(s)
- Ayman H Kamel
- Department of chemistry, College of Science, University of Bahrain, Sakhir, 32038, Kingdom of Bahrain.
- Chemistry Department, Faculty of Science, Ain Shams University, Cairo, 11566, Egypt.
| | - Hisham S M Abd-Rabboh
- Chemistry Department, Faculty of Science, King Khalid University, 62529, Abha, Saudi Arabia
| | - Majed A Bajaber
- Chemistry Department, Faculty of Science, King Khalid University, 62529, Abha, Saudi Arabia
| |
Collapse
|
2
|
Almehizia A, Naglah AM, Alanazi MG, Amr AEGE, Kamel AH. Paper-Based Analytical Device Based on Potentiometric Transduction for Sensitive Determination of Phenobarbital. ACS OMEGA 2023; 8:43538-43545. [PMID: 38027332 PMCID: PMC10666222 DOI: 10.1021/acsomega.3c03977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 09/29/2023] [Indexed: 12/01/2023]
Abstract
In medicine, barbiturates are a class of depressive medications used as hypnotics, anticonvulsants, and anxiolytics. For the treatment of specific forms of epilepsy and seizures in young children in underdeveloped countries, the World Health Organization recommends phenobarbital (PBAR), a barbiturate drug. This review describes the fabrication and characterization of a paper-based analytical apparatus for phenobarbital detection that is straightforward, affordable, portable, and disposable. All of the solid-state ion-selective electrodes (ISEs) for PBAR as well as a Ag/AgCl reference electrode were constructed and optimized on a nonconductive paper substrate. Using carbon nanotube ink, the sensors were made to function as an ion-to-electron transducer and to make the paper conductive. A suitable polymeric membrane is drop-cast onto the surface of the carbon ink orifice. The pyrido-tetrapeptide and pyrido-hexapeptide derivatives, which were recently synthesized, functioned as distinct ionophores in the PBAR-membrane sensor, enabling its detection. With a detection limit of 5.0 × 10-7 M, the manufactured analytical device demonstrated a Nernstian response to PBAR anions in 50 mM phosphate buffer, pH 8.5, over a linear range of 1.0 × 10-6 to 1.0 × 10-3 M. The PBAR-based sensors showed quick (less than 5 s) response times for PBAR ion detection. The modified separate solution method was utilized to evaluate the selectivity pattern of these novel ionophores with respect to PBAR ions in comparison to other common anions. The analytical instrument that was exhibited on paper had good precision both within and between days. The suggested technology assisted in the detection of trace amounts of PBAR in real pharmaceutical samples. A comparison was made between the data acquired using the HPLC reference method and the information obtained by the recommended potentiometric approach. The described paper-based analytical device may be a good choice for point-of-care PBAR determination because it is cheap and easy to find and can self-pump (especially when combined with potentiometric detection).
Collapse
Affiliation(s)
- Abdulrahman
A. Almehizia
- Drug
Exploration and Development Chair (DEDC), Department of Pharmaceutical
Chemistry, College of Pharmacy, King Saud
University, P. O. Box 2457,Riyadh 11451, Saudi Arabia
| | - Ahmed M. Naglah
- Drug
Exploration and Development Chair (DEDC), Department of Pharmaceutical
Chemistry, College of Pharmacy, King Saud
University, P. O. Box 2457,Riyadh 11451, Saudi Arabia
| | - Mashael G. Alanazi
- Department
of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457,Riyadh 11451, Saudi Arabia
| | - Abd El-Galil E. Amr
- Applied
Organic Chemistry Department, National Research
Center, Dokki, Giza 12622, Egypt
| | - Ayman H. Kamel
- Department,
College of Science, University of Bahrain, Sokheer 32038, Kingdom of Bahrain
- Department
of Chemistry, Faculty of Science, Ain Shams
University, Cairo 11566, Egypt
| |
Collapse
|
3
|
Bajaber MA, Kamel AH. All-Solid State Potentiometric Sensors for Desvenlafaxine Detection Using Biomimetic Imprinted Polymers as Recognition Receptors. Polymers (Basel) 2022; 14:polym14224814. [PMID: 36432940 PMCID: PMC9693087 DOI: 10.3390/polym14224814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 10/28/2022] [Accepted: 11/02/2022] [Indexed: 11/12/2022] Open
Abstract
Using single-walled carbon nanotubes (SWCNTs) as an ion-to-electron transducer, a novel disposable all-solid-state desvenlafaxine-selective electrode based on a screen-printed carbon paste electrode was created. SWCNTs were put onto the carbon-paste electrode area, which was protected by a poly (vinyl chloride) (PVC) membrane with a desvenlafaxine-imprinted polymer serving as a recognition receptor. Electrochemical impedance spectroscopy and chronopotentiometric techniques were used to examine the electrochemical characteristics of the SWCNTs/PVC coating on the carbon screen-printed electrode. The electrode displayed a 57.2 ± 0.8 mV/decade near-Nernstian slope with a 2.0 × 10-6 M detection limit. In 10 mM phosphate buffer, pH 6, the ODV-selective electrodes displayed a quick reaction (5 s) and outstanding stability, repeatability, and reproducibility. The usefulness of electrodes was demonstrated in samples of ODV-containing pharmaceutical products and human urine. These electrodes have the potential to be mass produced and employed as disposable sensors for on-site testing, since they are quick, practical, and inexpensive.
Collapse
Affiliation(s)
- Majed A. Bajaber
- Chemistry Department, Faculty of Science, King Khalid University, Abha 61413, Saudi Arabia
| | - Ayman H. Kamel
- Chemistry Department, Faculty of Science, Ain Shams University, Cairo 11566, Abbasia, Egypt
- Chemistry Department, College of Science, Sakhir 32038, Bahrain
- Correspondence:
| |
Collapse
|
4
|
Abd-Rabboh HSM, E. Amr AEG, Almehizia AA, Naglah AM, H. Kamel A. New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment. Polymers (Basel) 2022; 14:polym14101942. [PMID: 35631825 PMCID: PMC9145760 DOI: 10.3390/polym14101942] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 04/15/2022] [Accepted: 04/18/2022] [Indexed: 11/29/2022] Open
Abstract
Caffeine is a psychoactive drug that is administered as a class II psychotropic substance. It is also considered a component of analgesics and cold medicines. Excessive intake of caffeine may lead to severe health damage or drug addiction problems. The assessment of normal caffeine consumption from abusive use is not conclusive, and the cut-off value for biological samples has not been established. Herein, new cost-effective and robust all-solid-state platforms based on potentiometric transduction were fabricated and successfully utilized for caffeine assessment. The platforms were modified with reduced graphene oxide (rGO). Tailored caffeine-imprinted polymeric beads (MIPs) based on methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) were prepared, characterized, and used as recognition receptors in the presented potentiometric sensing devices. In 50 mM MES buffer, the sensors exhibited a slope response of 51.2 ± 0.9 mV/decade (n = 6, R2 = 0.997) over the linear range of 4.5 × 10−6−1.0 × 10−3 M with a detection limit of 3.0 × 10−6 M. They exhibited fast detection of caffeinium ions with less than 5 s response time (<5 s). The behavior of the presented sensors towards caffeinium ions over many common organic and inorganic cations was evaluated using the modified separate solution method (MSSM). Inter-day and intra-day precision for the presented analytical device was also evaluated. Successful applications of the presented caffeine sensors for caffeine determination in commercial tea and coffee and different pharmaceutical formulations were carried out. The data obtained were compared with those obtained by the standard liquid chromatographic approach. The presented analytical device can be considered an attractive tool for caffeine determination because of its affordability and vast availability, particularly when combined with potentiometric detection.
Collapse
Affiliation(s)
- Hisham S. M. Abd-Rabboh
- Chemistry Department, Faculty of Science, King Khalid University, P.O. Box 9004, Abha 61413, Saudi Arabia;
- Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt
| | - Abdel El-Galil E. Amr
- Pharmaceutical Chemistry Department, College of Pharmacy, Drug Exploration and Development Chair (DEDC), King Saud University, Riyadh 11451, Saudi Arabia; (A.A.A.); (A.M.N.)
- Applied Organic Chemistry Department, National Research Center, Dokki, Giza 12622, Egypt
- Correspondence: (A.E.-G.E.A.); or (A.H.K.)
| | - Abdulrahman A. Almehizia
- Pharmaceutical Chemistry Department, College of Pharmacy, Drug Exploration and Development Chair (DEDC), King Saud University, Riyadh 11451, Saudi Arabia; (A.A.A.); (A.M.N.)
| | - Ahmed M. Naglah
- Pharmaceutical Chemistry Department, College of Pharmacy, Drug Exploration and Development Chair (DEDC), King Saud University, Riyadh 11451, Saudi Arabia; (A.A.A.); (A.M.N.)
- Applied Organic Chemistry Department, National Research Center, Dokki, Giza 12622, Egypt
| | - Ayman H. Kamel
- Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt
- Chemistry Department, College of Science, Sakhir 32038, Bahrain
- Correspondence: (A.E.-G.E.A.); or (A.H.K.)
| |
Collapse
|
5
|
All-Solid-State Potentiometric Platforms Modified with a Multi-Walled Carbon Nanotubes for Fluoxetine Determination. MEMBRANES 2022; 12:membranes12050446. [PMID: 35629772 PMCID: PMC9144631 DOI: 10.3390/membranes12050446] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 04/07/2022] [Accepted: 04/08/2022] [Indexed: 01/25/2023]
Abstract
Novel cost-effective screen-printed potentiometric platforms for simple, fast, and accurate assessment of Fluoxetine (FLX) were designed and characterized. The potentiometric platforms integrate both the FLX sensor and the reference Ag/AgCl electrode. The sensors were based on the use of 4′-nitrobenzo-15-crown-5 (ionophore I), dibenzo-18-crown-6 (ionophore II), and 2-hydroxypropyl-β-cyclodextrin (2-HP-β-CD) (ionophore III) as neutral carriers within a plasticized PVC matrix. Multiwalled carbon nanotubes (MWCNTs) were used as a lipophilic ion-to-electron transducing material and sodium tetrakis [3,5-bis(trifluoromethyl)phenyl] borate (NaTFPB) was used as an anionic excluder. The presented platforms revealed near-Nernstian potentiometric response with slopes of 56.2 ± 0.8, 56.3 ± 1.7 and 64.4 ± 0.2 mV/decade and detection limits of 5.2 × 10−6, 4.7 × 10−6 and 2.0 × 10−7 M in 10 mM Tris buffer solution, pH 7 for sensors based on ionophore I, II, and III, respectively. All measurements were carried out in 10 mM tris buffer solution at pH 7.0. The interfacial capacitance before and after insertion of the MWCNTs layer was evaluated for the presented sensors using the reverse-current chronopotentiometry. The sensors were introduced for successful determination of FLX drug in different pharmaceutical dosage forms. The results were compared with those obtained by the standard HPLC method. Recovery values were calculated after spiking fixed concentrations of FLX in different serum samples. The presented platforms can be potentially manufacturable at large scales and provide a portable, rapid, disposable, and cost-effective analytical tool for measuring FLX.
Collapse
|
6
|
Amr AEGE, Kamel AH, Almehizia AA, Sayed AYA, Abd-Rabboh HSM. Solid-Contact Potentiometric Sensors Based on Main-Tailored Bio-Mimics for Trace Detection of Harmine Hallucinogen in Urine Specimens. Molecules 2021; 26:molecules26020324. [PMID: 33435196 PMCID: PMC7826799 DOI: 10.3390/molecules26020324] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 01/06/2021] [Accepted: 01/07/2021] [Indexed: 11/21/2022] Open
Abstract
All-solid-state potentiometric sensors have attracted great attention over other types of potentiometric sensors due to their outstanding properties such as enhanced portability, simplicity of handling, affordability and flexibility. Herein, a novel solid-contact ion-selective electrode (SC-ISE) based on poly(3,4-ethylenedioxythiophene) (PEDOT) as the ion-to-electron transducer was designed and characterized for rapid detection of harmine. The harmine-sensing membrane was based on the use of synthesized imprinted bio-mimics as a selective material for this recognition. The imprinted receptors were synthesized using acrylamide (AA) and ethylene glycol dimethacrylate (EGDMA) as functional monomer and cross-linker, respectively. The polymerization process was carried out at 70 °C in the presence of dibenzoyl peroxide (DBO) as an initiator. The sensing membrane in addition to the solid-contact layer was applied to a glassy-carbon disc as an electronic conductor. All performance characteristics of the presented electrode in terms of linearity, detection limit, pH range, response time and selectivity were evaluated. The sensor revealed a wide linearity over the range 2.0 × 10−7–1.0 × 10−2 M, with a detection limit of 0.02 µg/mL and a sensitivity slope of 59.2 ± 0.8 mV/hamine concentration decade. A 40 mM Britton–Robinson (BR) buffer solution at pH of 6 was used for all harmine measurements. The electrode showed good selectivity towards harmine over other common interfering ions, and maintained a stable electrochemical response over two weeks. After applying the validation requirements, the proposed method revealed good performance characteristics. Method precision, accuracy, bias, trueness, repeatability, reproducibility, and uncertainty were also evaluated. These analytical capabilities support the fast and direct assessment of harmine in different urine specimens. The analytical results were compared with the standard liquid chromatographic method. The results obtained demonstrated that PEDOT/PSS was a promising solid-contact ion-to-electron transducer material in the development of harmine-ISE. The electrodes manifested enhanced stability and low cost, which provides a wide number of potential applications for pharmaceutical and forensic analysis.
Collapse
Affiliation(s)
- Abde El-Galil E. Amr
- Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia;
- Applied Organic Chemistry Department, National Research Center, Dokki, Giza 12622, Egypt; (A.A.A.); (A.Y.A.S.)
| | - Ayman H. Kamel
- Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt
- Correspondence: (A.H.K.); (H.S.M.A.-R.); Tel.: +966-565-148-750 (H.S.M.A.-R.)
| | - Abdulrahman A. Almehizia
- Applied Organic Chemistry Department, National Research Center, Dokki, Giza 12622, Egypt; (A.A.A.); (A.Y.A.S.)
| | - Ahmed Y. A. Sayed
- Applied Organic Chemistry Department, National Research Center, Dokki, Giza 12622, Egypt; (A.A.A.); (A.Y.A.S.)
| | - Hisham S. M. Abd-Rabboh
- Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt
- Chemistry Department, Faculty of Science, King Khalid University, P.O. Box 9004, Abha 61413, Saudi Arabia
- Correspondence: (A.H.K.); (H.S.M.A.-R.); Tel.: +966-565-148-750 (H.S.M.A.-R.)
| |
Collapse
|
7
|
Screen-Printed Sensor Based on Potentiometric Transduction for Free Bilirubin Detection as a Biomarker for Hyperbilirubinemia Diagnosis. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors8030086] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Novel reliable and cost-effective potentiometric screen-printed sensors for free bilirubin (BR) detection were presented. The sensors were fabricated using ordered mesoporous carbon (OMC) as an ion-to-electron transducer. The ion-association complex [Ni(bphen)3]2+[BR]2− was utilized as a sensory recognition material in the plasticized Polyvinyl Chloride (PVC) membrane. The membrane was drop-casted on the OMC layer, which is attached on a carbon conductor (2-mm diameter). In a 50 mM phosphate solution of pH 8.5, the electrodes offered a Nernstian slope of −26.8 ± 1.1 (r2 = 0.9997) mV/decade with a range of linearity 1.0 × 10−6–1 × 10−2 M towards free bilirubin with a detection limit 8.8 × 10−7 M (0.52 µg/mL). The presented sensors offered good features in terms of reliability, ease of design, high potential stability, high specificity and good accuracy and precision. Chronopotentiometric and electrochemical impedance spectrometric measurements were used for short-term potential stability and interfacial capacitance calculations. The sensors were used for the determination of free bilirubin in biological fluids. The data obtained are fairly well consistent with those obtained by the reference spectophotometric method. Based on the interaction of free BR with albumin (1:1), the sensors were also utilized for the assessment of albumin in human serum.
Collapse
|
8
|
Rapid and Accurate Validated Potentiometric Method for Bispyribac Herbicide Assessment in Rice and Agricultural Wastewater. WATER 2020. [DOI: 10.3390/w12082216] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A new validated method based on potentiometric transduction for bispyribac herbicide assessment in commercial formulations, rice and wastewater samples is fabricated and characterized. Sensors are based in terms of their fabrication on tridodecyl methyl ammonium chloride (TDMAC) as recognition material. TDMAC was plasticized in a poly (vinyl chloride) (PVC) matrix to prepare the membrane. Under static modes of operation, the sensors revealed a Nernstian anionic slope of −63.6 ± 0.7 mV/decade within a linear range of 9.1 × 10−6–1.0 × 10−2 in 50 mM phosphate buffer solution (PBS), pH7. The detection limit was 6.0 × 10−6 M. The sensor was successfully introduced in a flow-stream system revealing a Nernstian response of −53.8 ± 1.3 mV/decade over a linear range of 2 × 10−4–1.0 × 10−2 M and lower detection limit of 5.6 × 10⁻⁵ M. The sampling rate was calculated to be (~42 sample/h). Validation of the assay method is presented in detail including accuracy, trueness, bias, between-day variability and within-day variability, and good performance characteristics of the method are obtained. The presented method was successfully introduced to bispyribac determination in different complex matrices such as commercial bispyribac sodium known as (Nominee-kz, 3% soluble liquid (SL)), rice samples and agricultural wastewater samples. The samples were analyzed successfully under both static and hydrodynamic modes of operation. The results obtained were in a good agreement with those obtained by the liquid chromatographic method.
Collapse
|
9
|
Kamel AH, Amr AEGE, Galal HR, Almehizia AA. Novel Validated Analytical Method Based on Potentiometric Transduction for the Determination of Citicoline Psychostimulant/Nootropic Agent. Molecules 2020; 25:molecules25153512. [PMID: 32752083 PMCID: PMC7435782 DOI: 10.3390/molecules25153512] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 07/29/2020] [Accepted: 07/31/2020] [Indexed: 11/29/2022] Open
Abstract
Herein, a novel validated potentiometric method is presented for the first time for citicoline determination. The method is based on measuring the potential using new constructed citicoline electrodes. The electrodes are based on the use of citicolinium/phosphomolybdate [Cit]2[PM] (sensor I) and citicolinium/tetraphenylborate [Cit][TPB] (sensor II) ion association complexes. These sensory materials were dispersed in plasticized polyvinyl chloride (PVC) polymeric membranes. The sensors revealed a Nernstian response with the slopes 55.9 ± 1.8(r2 = 0.9994) and 51.8 ± 0.9 (r2 = 0.9991) mV/decade over a linearity range of 6.3 × 10−6–1.0 × 10−3 and 1.0 × 10−5–1.0 × 10−3 M and detection limits of 3.16 × 10−6 and 7.1 × 10−6 M for sensors I and II, respectively. To ensure the existence of monovalent citicoline, all measurements were performed in 50 mM acetate buffer at pH 3.5. All presented electrodes showed good performance characteristics such as rapid response, good selectivity, high potential-stability and long life-span. Method verification and validation in terms of response linearity, quantification limit, accuracy, bias, trueness, robustness, within-day variability and between-days variability were evaluated. The method was introduced for citicoline determination in different pharmaceutical formulations and compared with the standard high performance liquid chromatography (HPLC) method.
Collapse
Affiliation(s)
- Ayman H. Kamel
- Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt
- Correspondence: (A.H.K.); (A.E.-G.E.A.); Tel.: +20-100-074-3328 (A.H.K.); +966-565-148-750 (A.E.-G.E.A.)
| | - Abd El-Galil E. Amr
- Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia;
- Applied Organic Chemistry Department, National Research Center, Dokki 12622, Giza, Egypt
- Correspondence: (A.H.K.); (A.E.-G.E.A.); Tel.: +20-100-074-3328 (A.H.K.); +966-565-148-750 (A.E.-G.E.A.)
| | - Hoda R. Galal
- Inorganic Chemistry Department, National Research Center, Dokki 12622, Giza, Egypt;
| | - Abdulrahman A. Almehizia
- Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia;
| |
Collapse
|
10
|
Validation of a Novel Potentiometric Method Based on a Polymeric PVC Membrane Sensor Integrated with Tailored Receptors for the Antileukemia Drug Cytarabine. Polymers (Basel) 2020; 12:polym12061343. [PMID: 32545861 PMCID: PMC7361695 DOI: 10.3390/polym12061343] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 06/06/2020] [Accepted: 06/11/2020] [Indexed: 12/03/2022] Open
Abstract
A simple, rapid and easy method is proposed for the detection of a cytostatic therapeutic drug, cytarabine, in real samples. The method is based on potentiometric transduction using prepared and characterized new ion-selective electrodes for cytarabine. The electrodes were integrated with novel man-tailored imprinted polymers and used as a sensory element for recognition. The electrodes revealed a remarkable potentiometric response for cytarabine over the linearity range 1.0 × 10−6–1.0 × 10−3 M at pH 2.8–4 with a detection limit of 5.5 × 10−7 M. The potentiometric response was near-Nernstian, with average slopes of 52.3 ± 1.2 mV/decade. The effect of lipophilic salts and plasticizer types on the potentiometric response was also examined. The electrodes exhibited an enhanced selectivity towards cytarabine over various foreign common ions. Validation and verification of the presented assay method are demonstrated by evaluating the method ruggedness and calculating the detection limit, range of linearity, accuracy (trueness), precision, repeatability (within-day) and reproducibility (between-days). The proposed ion-selective electrodes revealed good performance characteristics and possible application of these electrodes for cytarabine monitoring in different matrices. The electrodes are successfully applied to cytarabine determination in spiked biological fluid samples and in pharmaceutical formulations.
Collapse
|
11
|
Modified Potentiometric Screen-Printed Electrodes Based on Imprinting Character for Sodium Deoxycholate Determination. Biomolecules 2020; 10:biom10020251. [PMID: 32041305 PMCID: PMC7072443 DOI: 10.3390/biom10020251] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Revised: 02/04/2020] [Accepted: 02/04/2020] [Indexed: 11/16/2022] Open
Abstract
Potentiometric sensors have a great influence on the determination of most various compounds in their matrices. Therefore, efficient and new sensors were introduced to measure sodium Deoxycholate (NaDC) as a bile acid salt. These sensors are based on NaDC imprinted polymer (MIP) as sensory element. The MIP beads were synthesized using thermal polymerization pathway, in which acrylamide (AAm), ethylene glycol dimethacrylate (EGDMA), NaDC, and benzoyl peroxide (BPO) were used as the functional monomer, cross-linker, template, and initiator, respectively. The proposed sensors were fabricated using a coated screen-printed platform and the sensing membrane was modified by single-walled carbon nanotubes (SWCNTs) as an ion-to-electron transducer. The sensors exhibited high sensitivity that reached 4.7 × 10−5 M of near-Nernestian slope (−60.1 ± 0.9 mV/decade, r2 = 0.999 (n= 5)). In addition, the sensors revealed high selectivity, long lifetime, high potential stability, and conductivity that ensure reproducible and accurate results over a long time. MIP characterization was performed using Fourier Transform-Infrared (FT-IR) and a scanning electron microscope (SEM). Regarding the interaction of NaDC with serum albumin (SA), albumin is determined in human serum samples as human serum albumin (HSA), which was collected from different volunteers of different ages and gender.
Collapse
|
12
|
Kazıcı HÇ, Yayla M, Ulaş B, Aktaş N, Kivrak H. Development of Nonenzymatic Benzoic Acid Detection on PdSn/GCE/Vulcan XC‐72R Prepared via Polyol Method. ELECTROANAL 2019. [DOI: 10.1002/elan.201900088] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Hilal Çelik Kazıcı
- Department of Chemical EngineeringFaculty of EngineeringVan Yüzüncü Yıl University 65080 Van Turkey
| | - Müge Yayla
- Department of Chemical EngineeringFaculty of EngineeringVan Yüzüncü Yıl University 65080 Van Turkey
| | - Berdan Ulaş
- Department of Chemical EngineeringFaculty of EngineeringVan Yüzüncü Yıl University 65080 Van Turkey
| | - Nahit Aktaş
- Department of Chemical EngineeringFaculty of EngineeringKyrgyz-Turkish Manas University Kyrgyz Republic
| | - Hilal Kivrak
- Department of Chemical EngineeringFaculty of EngineeringVan Yüzüncü Yıl University 65080 Van Turkey
| |
Collapse
|
13
|
Boroumand S, Chamjangali MA, Bagherian G. Double injection/single detection asymmetric flow injection manifold for spectrophotometric determination of ascorbic acid and uric acid: Selection the optimal conditions by MCDM approach based on different criteria weighting methods. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2017; 174:203-213. [PMID: 27915157 DOI: 10.1016/j.saa.2016.11.031] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Revised: 11/07/2016] [Accepted: 11/16/2016] [Indexed: 06/06/2023]
Abstract
A simple and sensitive double injection/single detector flow injection analysis (FIA) method is proposed for the simultaneous kinetic determination of ascorbic acid (AA) and uric acid (UA). This method is based upon the difference between the rates of the AA and UA reactions with Fe3+ in the presence of 1, 10-phenanthroline (phen). The absorbance of Fe2+/1, 10-phenanthroline (Fe-phen) complex obtained as the product was measured spectrophotometrically at 510nm. To reach a good accuracy in the differential kinetic determination via the mathematical manipulations of the transient signals, different criteria were considered in the selection of the optimum conditions. The multi criteria decision making (MCDM) approach was applied for the selection of the optimum conditions. The importance weights of the evaluation criteria were determined using the analytic hierarchy process, entropy method, and compromised weighting (CW). The experimental conditions (alternatives) were ranked by the technique for order preference by similarity to an ideal solution. Under the selected optimum conditions, the obtained analytical signals were linear in the ranges of 0.50-5.00 and 0.50-4.00mgL-1 for AA and UA, respectively. The 3σ detection limits were 0.07mgL-1 for AA and 0.12mgL-1 for UA. The relative standard deviations for four replicate determinations of AA and UA were 2.03% and 3.30% respectively. The method was also applied for the analysis of analytes in the blood serum, Vitamine C tablets, and tap water with satisfactory results.
Collapse
Affiliation(s)
- Samira Boroumand
- College of Chemistry, Shahrood University of Technology, Shahrood, P.O. Box 36155-316, Iran
| | | | - Ghadamali Bagherian
- College of Chemistry, Shahrood University of Technology, Shahrood, P.O. Box 36155-316, Iran
| |
Collapse
|
14
|
Potentiometric determination of ascorbic acid in water–acetonitrile solution using pyrite and chalcopyrite electrodes. J Solid State Electrochem 2016. [DOI: 10.1007/s10008-016-3295-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
15
|
Determination of ascorbic acid levels in food samples by using an ionic liquid–carbon nanotube composite electrode. Food Chem 2012; 135:362-7. [DOI: 10.1016/j.foodchem.2012.05.013] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2011] [Revised: 03/04/2012] [Accepted: 05/02/2012] [Indexed: 11/21/2022]
|
16
|
Wang Z, Teng X, Lu C. Carbonate interlayered hydrotalcites-enhanced peroxynitrous acid chemiluminescence for high selectivity sensing of ascorbic acid. Analyst 2012; 137:1876-81. [DOI: 10.1039/c2an00030j] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
17
|
Xu Q, Bi L, Zheng H, Fan D, Wang W. PDMS-based gold electrode for sensing ascorbic acid. Colloids Surf B Biointerfaces 2011; 88:362-5. [DOI: 10.1016/j.colsurfb.2011.07.014] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2011] [Revised: 05/10/2011] [Accepted: 07/05/2011] [Indexed: 11/30/2022]
|
18
|
Flow injection fluorometric determination of ascorbic acid using perylenebisimide-linked nitroxide. Talanta 2011; 85:1730-3. [DOI: 10.1016/j.talanta.2011.06.054] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2011] [Revised: 06/21/2011] [Accepted: 06/21/2011] [Indexed: 11/23/2022]
|
19
|
Comparison of Pt and Ni foil electrodes for amperometric sensing of ascorbic acid. J Electroanal Chem (Lausanne) 2011. [DOI: 10.1016/j.jelechem.2010.11.031] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|