1
|
Geng C, Dong Z, Zhang T, Yang Z, Xu Z, Liang S, Ding X. Advances in atmospheric pressure plasma-based optical emission spectrometry for the analysis of heavy metals. Talanta 2024; 270:125634. [PMID: 38215585 DOI: 10.1016/j.talanta.2024.125634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 01/03/2024] [Accepted: 01/04/2024] [Indexed: 01/14/2024]
Abstract
Over the past decade, miniaturized optical emission spectrometry (OES) systems utilizing atmospheric pressure plasmas (APPs) as radiation sources have exhibited impressive capabilities in trace heavy metal analysis. As the core of the analytical system, APPs sources possess unique properties such as compact size, light weight, low energy requirement, ease of fabrication, and relatively low manufacturing cost. This critical review focuses on recent progress of APP-based OES systems employed for the determination of heavy metals. Influences of technical details including the sample introduction manner, the sampling volume, the sample flow rate, the pH of the solutions on the plasma stability and the intensity of analytical signals are comprehensively discussed. Furthermore, the review emphasizes the analytical challenges faced by these techniques and highlights the opportunities for further development in the field of heavy metal detection.
Collapse
Affiliation(s)
- Chaoqun Geng
- Department of Pharmaceutical Analysis, School of Pharmacy, Qingdao University, Qingdao, 266071, China
| | - Zheng Dong
- Shandong Qingdao Hospital of Integrated Traditional and Western Medicine, Qingdao, 266002, China
| | - Tiantian Zhang
- Department of Pharmaceutical Analysis, School of Pharmacy, Qingdao University, Qingdao, 266071, China
| | - Zhao Yang
- Qingdao Institute for Food and Drug Control, Qingdao 266071, China
| | - Zewen Xu
- Shandong Institute for Food and Drug Control, Jinan 250101, China
| | - Shuai Liang
- Department of Pharmaceutical Chemistry, School of Pharmacy, Qingdao University, Qingdao, 266071, China.
| | - Xuelu Ding
- Department of Pharmaceutical Analysis, School of Pharmacy, Qingdao University, Qingdao, 266071, China.
| |
Collapse
|
2
|
Angyus SB, Senila M, Frentiu T, Ponta M, Frentiu M, Covaci E. In-situ Diffusive Gradients in thin-films passive sampling coupled with ex-situ small-sized electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry as green and white method for the simultaneous determination of labile species of toxic elements in surface water. Talanta 2023; 259:124551. [PMID: 37075518 DOI: 10.1016/j.talanta.2023.124551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 04/06/2023] [Accepted: 04/11/2023] [Indexed: 04/21/2023]
Abstract
This study presents for the first time the coupling between in-situ Diffusive Gradient in Thin-film (DGT) passive sampling technique and ex-situ small-sized instrumentation based on electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry (SSETV-μCCP-OES) for the simultaneous determination of Cd, Pb, Cu, Zn and Hg in surface water. Unique features of the DGT-SSETV-μCCP-OES are low power and low Ar consumption for plasma generation (15 W, 150 mL min-1) and significant improvement of the detection limits following DGT passive sampling. The new method was validated in terms of river water analysis in comparison with graphite furnace atomic absorption spectrometry and thermal decomposition atomic absorption spectrometry. Combining the abilities of preconcentration by in-situ Chelex-DGT passive sampling with plasma microtorch equipped with a low resolution microspectrometer provided multielemental simultaneous determination with detection limits of (μg L-1) 0.01 (Cd, Zn and Hg), 0.02 (Cu) and 0.07 (Pb) in water, at least one order of magnitude better than using grab sampling without preconcentration. It was possible the quantification of labile fraction of priority hazardous metals (Cd, Pb) in river water below the instrumental limits of detection (μg L-1) of 0.12 and 0.80 obtained in SSETV-μCCP-OES without DGT sampling. The precision of the method was in the range 15.3-22.4% (combined uncertainty), while the accuracy was 95-103% and trueness of 27-33% (expanded uncertainty, k = 2). The DGT-SSETV-μCCP-OES coupling proved to be an ideal and powerful tool for surface water analysis in compliance with green and white analytical chemistry concepts. The application of the RGB-12 algorithm provided very good red/green (AGREEprep)/blue/white scores (%) of 100/80/98/93, determined primarily by in-situ DGT passive sampling, very good detection limits and cost-effective SSETV-μCCP-OES instrumentation.
Collapse
Affiliation(s)
- Simion Bogdan Angyus
- National Institute for Research and Development of Optoelectronics INOE 2000 INCD Bucharest, Research Institute for Analytical Instrumentation, Donath 67, 400293 Cluj-Napoca, Romania; Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, Arany Janos 11, 400028 Cluj-Napoca, Romania; Babes-Bolyai University, Research Center for Advanced Analysis, Instrumentation and Chemometrics, Arany Janos 11, 400028 Cluj-Napoca, Romania
| | - Marin Senila
- National Institute for Research and Development of Optoelectronics INOE 2000 INCD Bucharest, Research Institute for Analytical Instrumentation, Donath 67, 400293 Cluj-Napoca, Romania
| | - Tiberiu Frentiu
- Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, Arany Janos 11, 400028 Cluj-Napoca, Romania; Babes-Bolyai University, Research Center for Advanced Analysis, Instrumentation and Chemometrics, Arany Janos 11, 400028 Cluj-Napoca, Romania
| | - Michaela Ponta
- Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, Arany Janos 11, 400028 Cluj-Napoca, Romania; Babes-Bolyai University, Research Center for Advanced Analysis, Instrumentation and Chemometrics, Arany Janos 11, 400028 Cluj-Napoca, Romania
| | - Maria Frentiu
- National Institute for Research and Development of Optoelectronics INOE 2000 INCD Bucharest, Research Institute for Analytical Instrumentation, Donath 67, 400293 Cluj-Napoca, Romania
| | - Eniko Covaci
- Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, Arany Janos 11, 400028 Cluj-Napoca, Romania; Babes-Bolyai University, Research Center for Advanced Analysis, Instrumentation and Chemometrics, Arany Janos 11, 400028 Cluj-Napoca, Romania.
| |
Collapse
|
3
|
Cai Z, Qian L, Peng X, Wang Z. Direct Ultratrace Detection of Lead in a Single Hair Using Portable Electromagnetic Heating Vaporization-Atmospheric Pressure Glow Discharge-Atomic Emission Spectrometry. Anal Chem 2021; 93:14701-14707. [PMID: 34704432 DOI: 10.1021/acs.analchem.1c03057] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In this paper, the first demonstration of direct ultratrace determination of lead in a single human hair by direct current-atmospheric pressure glow discharge-atomic emission spectrometry (DC-APGD-AES) coupled with electromagnetic heating vaporization (EMV) was described. Only the ultramicro mass of a human hair sample (about 0.15 mg, often a single human hair) was required during the analysis, and fast detection was implemented without tedious pretreatment processes, such as grinding and digestion. A limit of detection (LOD) of 30.8 μg kg-1 (4.8 pg) for Pb was obtained under optimized conditions, which was even equivalent to that of conventional LA-ICP-MS/ETV-ICP-MS/GFAAS. EMV-APGD-AES, meanwhile, can facilitate miniaturization and portability with low power and small size. The accuracy and practicality of the method were verified by the analysis of certified reference materials (CRMs) GBW09101b (human hair) and human hair samples from three volunteers. A simple, efficient, and low-cost method for detecting Pb in human hair has been developed.
Collapse
Affiliation(s)
- Zhaoqing Cai
- Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China.,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Ling Qian
- Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China
| | - Xiaoxu Peng
- Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China
| | - Zheng Wang
- Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China.,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
4
|
Qian L, Lei Z, Peng X, Yang G, Wang Z. Highly sensitive determination of cadmium and lead in whole blood by electrothermal vaporization-atmospheric pressure glow discharge atomic emission spectrometry. Anal Chim Acta 2021; 1162:338495. [PMID: 33926695 DOI: 10.1016/j.aca.2021.338495] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 04/01/2021] [Accepted: 04/02/2021] [Indexed: 10/21/2022]
Abstract
In this study, a fast and simple method for highly sensitive detection of Cd and Pb elements based on atmospheric pressure glow discharge atomic emission spectrometry (APGD-AES) coupling with tungsten coil electrothermal vaporization (ETV) was proposed. A small amount of sample (10 μL) was dropped onto the tungsten coil, followed by drying, pyrolysis and vaporization procedures, and then the vaporized analyte was transported to APGD for excitation. The whole procedure took approximately 3 min. Multi-step heating of the ETV unit can separate matrices and solvents from the analyte, providing an advantage in detecting samples with complex matrix. Under the optimal experimental conditions, limits of detection of 0.4 μg L-1 (4 pg) for cadmium and 1.2 μg L-1 (12 pg) for lead were obtained, with relative standard deviations of 20 μg L-1 Cd and 100 μg L-1 Pb both being <5%. The accuracy of the ETV-APGD-AES system was verified by the determination of heavy metals in whole blood standard sample (GBW(E)090,251) and the practicability of the ETV-APGD-AES system were demonstrated by the determination of heavy metals in human whole blood. The results obtained by this instrument agree well with the standard values and those obtained by ICP-MS.
Collapse
Affiliation(s)
- Ling Qian
- School of Material Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China; Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Zhendong Lei
- Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Xiaoxu Peng
- Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Guangzhi Yang
- School of Material Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| | - Zheng Wang
- Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China.
| |
Collapse
|
5
|
Simultaneous Determination of As, Bi, Sb, Se, Te, Hg, Pb and Sn by Small-Sized Electrothermal Vaporization Capacitively Coupled Plasma Microtorch Optical Emission Spectrometry Using Direct Liquid Microsampling. Molecules 2021; 26:molecules26092642. [PMID: 33946509 PMCID: PMC8124486 DOI: 10.3390/molecules26092642] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 04/26/2021] [Accepted: 04/28/2021] [Indexed: 11/16/2022] Open
Abstract
The simultaneous determination of chemical vapor-generating elements involving derivatization is difficult even by inductively coupled plasma optical emission spectrometry or mass spectrometry. This study proposes a new direct liquid microsampling method for the simultaneous determination of As, Bi, Se, Te, Hg, Pb, and Sn, using a fully miniaturized set-up based on electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry. The method is cost-effective, free from non-spectral interference, and easy to run by avoiding derivatization. The method involves the vaporization of analytes from the 10 µL sample and recording of episodic spectra generated in low-power (15 W) and low-Ar consumption (150 mL min−1) plasma microtorch interfaced with low-resolution microspectrometers. Selective vaporization at 1300 °C ensured the avoidance of non-spectral effects and allowed the use of external calibration. Several spectral lines for each element even in the range 180–210 nm could be selected. Generally, this spectral range is examined with large-scale instrumentation. Even in the absence of derivatization, the obtained detection limits were low (0.02–0.75 mg kg−1) and allowed analysis of environmental samples, such as cave and river sediments. The recovery was in the range of 86–116%, and the accuracy was better than 10%. The method is of general interest and could be implemented on any miniaturized or classical laboratory spectrometric instrumentation.
Collapse
|
6
|
Ferreira de Oliveira AP, Milani RF, Efraim P, Morgano MA, Tfouni SAV. Cd and Pb in cocoa beans: Occurrence and effects of chocolate processing. Food Control 2021. [DOI: 10.1016/j.foodcont.2020.107455] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
7
|
Senila M, Cadar O, Miu I. Development and Validation of a Spectrometric Method for Cd and Pb Determination in Zeolites and Safety Evaluation. Molecules 2020; 25:molecules25112591. [PMID: 32498463 PMCID: PMC7321230 DOI: 10.3390/molecules25112591] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2020] [Revised: 05/22/2020] [Accepted: 06/02/2020] [Indexed: 01/05/2023] Open
Abstract
An analytical method based on microwave-assisted acid digestion and atomic absorption spectrometry with graphite furnace as atomization source was developed and validated for determining trace elements (Cd and Pb) in zeolites used as dietary supplements, for their characterization and safety evaluation. The method was checked for the main performance parameters according to the legislation requirements in the field of dietary supplements. In all cases, the obtained performance parameters were satisfactory. The selectivity study showed no significant non-spectral matrix effect. The linearity study was conducted for the calibration curves in the range of 0–10 ng mL−1 for Cd and 0–30 ng mL−1 for Pb. The obtained limits of detection (LoDs) and the limits of quantification (LoQs) were sufficiently low in order to allow Pb and Cd determination in dietary supplements. For the internal quality control, certified reference materials were analysed and good recoveries were obtained. The precision study was performed in terms of repeatability and reproducibility, considering the requirements imposed by the Commission Decision (2007/333/EC) and the method fulfilled these performance parameters. Expanded measurement uncertainties were estimated to 11% for Cd and 10% for Pb. Cd and Pb content were measured in real zeolite samples and, using these data, a safety evaluation was carried out.
Collapse
Affiliation(s)
- Marin Senila
- National Institute for Research and Development of Optoelectronics Bucharest INOE 2000, Research Institute for Analytical Instrumentation, 67 Donath Street, 400293 Cluj-Napoca, Romania;
- Correspondence: ; Tel.: +40-264-420590
| | - Oana Cadar
- National Institute for Research and Development of Optoelectronics Bucharest INOE 2000, Research Institute for Analytical Instrumentation, 67 Donath Street, 400293 Cluj-Napoca, Romania;
| | - Ion Miu
- SC UTCHIM SRL, 12 Buda Street, 240127 Ramnicu Valcea, Romania;
| |
Collapse
|
8
|
Interference-free, green microanalytical method for total mercury and methylmercury determination in biological and environmental samples using small-sized electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry. Talanta 2020; 217:121067. [PMID: 32498880 DOI: 10.1016/j.talanta.2020.121067] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Revised: 04/17/2020] [Accepted: 04/20/2020] [Indexed: 01/04/2023]
Abstract
An analytical method for the quantification of total Hg and CH3Hg+ in biological tissues (fish, mushroom) and water sediment was developed based on small-sized electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry using a low-resolution microspectrometer as detector. Sample preparation was carried out according to the procedure recommended by JRC Technical Report of European Commission for the determination of CH3Hg+ in seafood and adapted by us for lower consumption of reagents. Amounts of 0.1 - 0.5 g sample were subjected to extraction in 5 ml of 47% HBr then CH3Hg+ was extracted in 2 × 1 ml toluene and back-extracted in 2 ml aqueous solution of 1% l-cysteine. Total Hg/CH3Hg+ were quantified in 10 μl of acidic extract/l-cysteine solution after electrothermal vaporization and measurement of 253.652 nm Hg signal in the episodic emission spectra. Under the optimal working conditions of system (70 °C sample drying, 1300 °C sample vaporization, 10 W plasma power and 150 ml min-1 Ar flow) the limits of detection were 7.0 μg kg-1 total Hg and 3.5 μg kg-1 CH3Hg+. Comparison of slopes in external calibration and standard addition procedure revealed the lack of non-spectral interferences of multimineral matrix, so that the calibration against Hg2+ standards was adopted. Pooled recovery of total mercury/methylmercury was 101 ± 7%/100 ± 7%, while precision assessed from measurements of real samples was in the range 1.6-9.6%/2.7-12.8%. The proposed method validated according to Eurachem Guide 2014 is selective and complies with demands in European legislation (Decisions 657/2002; 333/2007; 836/2011) and Association of Official Analytical Chemists Guide in terms of performances for food control. The method displays a high degree of greenness by circumventing cold vapor generation, use of small amounts of reagents and full-miniaturized instrumentation resulting in low analytical costs without reducing results quality. Besides, the method is simple and rapid, since it uses external calibration curves prepared from Hg2+standard solutions both for total Hg and CH3Hg+ determination.
Collapse
|
9
|
Cai Y, Yu YL, Wang JH. Alternating-Current-Driven Microplasma for Multielement Excitation and Determination by Optical-Emission Spectrometry. Anal Chem 2018; 90:10607-10613. [PMID: 30070828 DOI: 10.1021/acs.analchem.8b02904] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Microplasma optical-emission spectrometry (OES) is a promising technique for developing portable analytical instrumentations for real-time and on-site measurement of trace elemental species. However, its analytical performance is far from satisfactory for multielement analysis. Herein, a miniature OES system is developed for simultaneous multielement analysis with alternating-current-driven microplasma generated on the nozzle of a pneumatic micronebulizer as the excitation source. Because of the strong excitation capability of the microplasma and its sufficient contact with solution, a series of elements, including Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Pb, and Zn, is directly excited in the spray with solution nebulization at a flow rate of 8 μL s-1. The characteristic optical emissions are measured by a charge-coupled-device (CCD) spectrometer. In addition, hydride generation is compatible with the present system, which makes it feasible for the simultaneous excitation of hydrides of As, Ge, Hg, Sb, and Sn by reaction with 0.8% (m/v) NaBH4. The microplasma-OES system exhibits a powerful capability for multielement analysis with favorable limits of detection for the mentioned elements.
Collapse
Affiliation(s)
- Yi Cai
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences , Northeastern University , Box 332, Shenyang 110819 , China
| | - Yong-Liang Yu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences , Northeastern University , Box 332, Shenyang 110819 , China
| | - Jian-Hua Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences , Northeastern University , Box 332, Shenyang 110819 , China
| |
Collapse
|
10
|
Miclean M, Cadar O, Levei L, Senila L, Ozunu A. Metal contents and potential health risk assessment of crops grown in a former mining district (Romania). JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART. B, PESTICIDES, FOOD CONTAMINANTS, AND AGRICULTURAL WASTES 2018; 53:595-601. [PMID: 29842846 DOI: 10.1080/03601234.2018.1473966] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Accepted: 04/18/2018] [Indexed: 06/08/2023]
Abstract
The Cd, Cu, Pb and Zn contents in home-grown crops in a former mining district were determined in order to evaluate the non-carcinogenic long-term potential health risk related to crop consumption. The potential health risk was investigated by estimating the daily intake and the hazard quotients. For all crop categories, the daily intake and the target hazard quotient were below the threshold values for Cd, Cu, and Zn. The daily intake of Pb exceeded the oral reference dose, while the target hazard quotient for vegetables was above 1, indicating a potential health risk. The total target hazard quotient for the individual metals decreased in the following order: Pb>Cd>Cu>Zn. This study confirmed that the daily consumption of crops grown in contaminated soils could pose health risks to humans.
Collapse
Affiliation(s)
- Mirela Miclean
- a INCDO INOE 2000, Research Institute for Analytical Instrumentation , Cluj-Napoca , Romania
- b Somes-Tisa Water Basin Administration , Cluj-Napoca , Romania
| | - Oana Cadar
- a INCDO INOE 2000, Research Institute for Analytical Instrumentation , Cluj-Napoca , Romania
| | - Levente Levei
- a INCDO INOE 2000, Research Institute for Analytical Instrumentation , Cluj-Napoca , Romania
- c Babes-Bolyai University, Environmental Science and Engineering Faculty , Cluj-Napoca , Romania
| | - Lacrimoara Senila
- a INCDO INOE 2000, Research Institute for Analytical Instrumentation , Cluj-Napoca , Romania
| | - Alexandru Ozunu
- c Babes-Bolyai University, Environmental Science and Engineering Faculty , Cluj-Napoca , Romania
| |
Collapse
|