1
|
Velagic V, Pasara V, Prepolec I, Nekic A, Katic Z, Milicic D. Feasibility and safety of zero-fluoro, "apron-less" approach to repeat pulmonary vein isolation procedures using radiofrequency energy after initial cryoballoon ablation. Sci Rep 2025; 15:4280. [PMID: 39905074 PMCID: PMC11794559 DOI: 10.1038/s41598-025-87940-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2024] [Accepted: 01/23/2025] [Indexed: 02/06/2025] Open
Abstract
We aimed to investigate the feasibility and safety of zero-fluoro approach for the repeat atrial fibrillation (AF) procedures after initial cryoballoon (CB) ablation. We have performed a retrospective study on patients that have undergone repeat pulmonary vein isolation (PVI) procedures in our institution since zero-fluoro program was initiated in 2020. All patients received CB ablation for the initial procedure. Repeat procedures were performed under conscious sedation and with intracardiac echo (ICE) and 3D mapping system - without the use of fluoroscopy and lead aprons. We have analysed in total 50 patients (76% male, 57.9 ± 10.2 years old), 50% of which suffered from paroxysmal AF. All procedures were successfully performed without the use of fluoroscopy. The mean procedure time was 93.9 ± 27.1 min and the mean RF time was 825 ± 468 s. The mean of 0.98 ± 0.91 veins was reconnected per patient and 36% of patients did not have PV reconnections. In all patients successful PV isolation was performed, confirmed by entry and exit block. No major periprocedural complications were observed. After the mean follow up of 12.5 ± 3.4 months: 68% of mixed AF population patients were free from AF after one year. In our cohort of patients, zero-fluoro, apron-less approach for repeat PVI procedures after index cryoballoon ablation proved to be feasible and safe. Index CB ablation resulted with low rates of PV reconnections and mid-term results after repeat procedures are favourable.
Collapse
Affiliation(s)
- Vedran Velagic
- Department of Cardiovascular Diseases, University of Zagreb School of Medicine, University Hospital Centre Zagreb, Kišpatićeva 12, 10000, Zagreb, Croatia.
| | - Vedran Pasara
- Department of Cardiovascular Diseases, University of Zagreb School of Medicine, University Hospital Centre Zagreb, Kišpatićeva 12, 10000, Zagreb, Croatia
| | - Ivan Prepolec
- Department of Cardiovascular Diseases, University of Zagreb School of Medicine, University Hospital Centre Zagreb, Kišpatićeva 12, 10000, Zagreb, Croatia
| | - Andrija Nekic
- Department of Cardiovascular Diseases, University of Zagreb School of Medicine, University Hospital Centre Zagreb, Kišpatićeva 12, 10000, Zagreb, Croatia
| | - Zvonimir Katic
- Department of Cardiovascular Diseases, University of Zagreb School of Medicine, University Hospital Centre Zagreb, Kišpatićeva 12, 10000, Zagreb, Croatia
| | - Davor Milicic
- Department of Cardiovascular Diseases, University of Zagreb School of Medicine, University Hospital Centre Zagreb, Kišpatićeva 12, 10000, Zagreb, Croatia
| |
Collapse
|
2
|
Isgandarova K, Bergau L, El Hamriti M, Braun M, Piran M, Imnadze G, Khalaph M, Molatta S, Sciacca V, Fink T, Sommer P, Guckel D, Sohns C. Impact of pulmonary vein anatomy and ostial dimensions on long-term outcome after single-shot device-guided cryoablation for paroxysmal atrial fibrillation. J Interv Card Electrophysiol 2023; 66:2125-2133. [PMID: 37145294 PMCID: PMC10694102 DOI: 10.1007/s10840-023-01554-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 04/19/2023] [Indexed: 05/06/2023]
Abstract
BACKGROUND Cryoballoon (CB)-guided pulmonary vein isolation (PVI) is an established treatment for atrial fibrillation (AF). This observational study aimed to assess the role of individual anatomical characteristics to predict long-term freedom from arrhythmia recurrence after CB-guided PVI for paroxysmal AF (PAF). METHODS Three hundred fifty three consecutive patients (58 ± 11 years, 56% males), undergoing PVI between 2012 and 2018 were analysed. Individual pulmonary vein (PV) anatomy was assessed using preprocedural cardiac magnetic resonance imaging (MRI). For each PV, the cross-sectional area (CSA) was calculated. The impact of PV characteristics and CSA on long-term AF-free survival was evaluated. RESULTS Acute PVI was achieved in all patients. Two hundred twenty-three patients (63%) had a normal PV anatomy (2 left- and 2 right-sided PV). Variant PV anatomy was present in 130 patients (37%). During the observation period of 48 months, AF-recurrence was documented in 167 patients (47 %). Patients with AF-recurrence presented with significantly enlarged right-sided PVs and left superior PVs (LSPVs) (p < 0.001). The presence of left common PVs (LCPVs) (n = 75, Log-rank p < 0.001) as well as right variant PVs (n = 35, Log rank p < 0.001) was associated with a significantly impaired long-term AF-free survival rate as compared to patients with normal PV characteristics. CONCLUSION Variant PV anatomy is a good predictor for AF-recurrence. A correlation between an enlarged CSA of right-sided PVs as well as LSPVs and AF-recurrence was documented.
Collapse
Affiliation(s)
- Khuraman Isgandarova
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany
| | - Leonard Bergau
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany
| | - Mustapha El Hamriti
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany
| | - Martin Braun
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany
| | - Misagh Piran
- Institute for Radiology, Nuclear Medicine and Molecular Imaging, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany
| | - Guram Imnadze
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany
| | - Moneeb Khalaph
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany
| | - Stephan Molatta
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany
| | - Vanessa Sciacca
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany
| | - Thomas Fink
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany
| | - Philipp Sommer
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany
| | - Denise Guckel
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany
| | - Christian Sohns
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, 32545, Bad Oeynhausen, Germany.
| |
Collapse
|
3
|
Bianchi S, De Simone A, Iacopino S, Fassini G, Malacrida M, Rossi P, Stabile G, Petretta A, Tundo F, Cauti FM, Iuliano S, Filannino P, Moltrasio M, Morlacchi Bonfanti M, Pelargonio G, Pecora D, Ferraro A, Tondo C. Pulmonary vein isolation by means of a novel cryoballoon technology in paroxysmal atrial fibrillation patients: 1-year outcome from a large Italian multicenter clinical registry. Pacing Clin Electrophysiol 2023; 46:1302-1309. [PMID: 37846769 DOI: 10.1111/pace.14839] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 07/04/2023] [Accepted: 10/01/2023] [Indexed: 10/18/2023]
Abstract
INTRODUCTION Recently, a new cryoballoon (CB) technology (POLARx; Boston Scientific) has come onto the market. Preliminary data have shown that its acute safety and efficacy are similar to those of the first-generation CB. The aim of this study was to assess the medium-term outcome of pulmonary vein isolation (PVI) with the POLARxTM CB in a large multicenter registry. METHODS We prospectively collected data on 125 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent PVI by means of a novel CB system. Two cases of transient phrenic nerve palsy occurred, with full recovery in the 48h post procedure; no major procedure-related adverse events were reported. During the 90-day blanking period, 4 (3.2%) patients experienced an early recurrence. After the blanking period, over a mean follow-up of 411 ± 62 days, 19 patients (15.2%) suffered an AF/atrial tachycardia (AT) recurrence. The 1-year freedom from AF/AT recurrence was 86.4% (n = 17): 10 (8%) patients had an AF recurrence, 6 (4.8%) had an AT occurrence and 1 (0.8%) suffered both events. Patients with AF/AT recurrences had both a shorter deflation time and total deflation time. Moreover, CB ablations with measured TTI < 90 s and TTI < 60 s were more frequent in patients without AF/AT recurrence (88.5% and 77.4%, respectively) than in those who experienced at least one AF/AT recurrence (67.5% and 55.0%, p = .001 and p = .005, respectively). CONCLUSION The novel POLARx cryo-balloon system is safe and effective for PV isolation, displaying a 1-year freedom from atrial arrhythmia recurrence of 86.4%, which is in line to that reported with AFA-Pro CB or RF ablation. CLINICAL TRIAL REGISTRATION Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998. Registration date: January 4, 2019.
Collapse
Affiliation(s)
- Stefano Bianchi
- Arrhythmology Unit, San Giovanni Calibita Hospital, Fatebefratelli, Rome, Italy
| | - Antonio De Simone
- Laboratorio di Elettrofisiologia, Clinica San Michele, Maddaloni, Caserta, Italy
| | | | - Gaetano Fassini
- Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy
| | | | - Pietro Rossi
- Arrhythmology Unit, San Giovanni Calibita Hospital, Fatebefratelli, Rome, Italy
| | - Giuseppe Stabile
- Laboratorio di Elettrofisiologia, Clinica San Michele, Maddaloni, Caserta, Italy
- Mediterranea Cardiocentro, Napoli, Italy
- Anthea Hospital, Bari, Italy
| | | | - Fabrizio Tundo
- Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy
| | - Filippo Maria Cauti
- Arrhythmology Unit, San Giovanni Calibita Hospital, Fatebefratelli, Rome, Italy
| | - Sara Iuliano
- Laboratorio di Elettrofisiologia, Clinica San Michele, Maddaloni, Caserta, Italy
| | | | - Massimo Moltrasio
- Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy
| | | | - Gemma Pelargonio
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
- Institute of Cardiology, Catholic University of Sacred Heart, Rome, Italy
| | - Domenico Pecora
- Electrophysiology Unit, Cardiovascular Department, Poliambulanza Institute Hospital Foundation, Brescia, Italy
| | - Anna Ferraro
- Cardiovascular Department, Infermi Hospital, Rivoli, Italy
| | - Claudio Tondo
- Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
| |
Collapse
|
4
|
Abstract
Cardiac arrhythmias remain a common cause of death and disability. Antiarrhythmic drugs (AADs) and antiarrhythmic agents remain a cornerstone of current cardiac arrhythmia management, despite moderate efficacy and the potential for significant adverse proarrhythmic effects. Due to conceptual, regulatory and financial considerations, the number of novel antiarrhythmic targets and agents in the development pipeline has decreased substantially during the last few decades. However, several promising candidates remain and there are exciting developments in repurposing and reformulating already existing drugs for indications related to cardiac arrhythmias. This review discusses the key conceptual considerations for the development of new antiarrhythmic agents, summarizes new compounds and formulations currently in clinical development for rhythm control of atrial fibrillation, and highlights the potential for drug repurposing. Finally, future directions in AAD development are discussed. Together with an ever-increasing understanding of the molecular mechanisms underlying cardiac arrhythmias, these components support a cautiously optimistic outlook towards improved pharmacological treatment opportunities for patients suffering from cardiac arrhythmias.
Collapse
Affiliation(s)
- Arnela Saljic
- Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
- Institute of Pharmacology, West German Heart and Vascular Center, University Duisburg-Essen, Essen, Germany
| | - Jordi Heijman
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, The Netherlands
| | - Dobromir Dobrev
- Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
- Montréal Heart Institute and University de Montréal, Medicine and Research Center, Montréal, Canada.
- Department of Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, USA.
- , Hufelandstrasse 55, 45122, Essen, Germany.
| |
Collapse
|
5
|
Wei Y, Lin C, Xie Y, Bao Y, Luo Q, Zhang N, Wu L. Development and validation of a novel nomogram for predicting recurrent atrial fibrillation after cryoballoon ablation. Front Cardiovasc Med 2023; 10:1073108. [PMID: 37636306 PMCID: PMC10453796 DOI: 10.3389/fcvm.2023.1073108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 07/24/2023] [Indexed: 08/29/2023] Open
Abstract
Background Few studies have explored the use of machine learning models to predict the recurrence of atrial fibrillation (AF) in patients who have undergone cryoballoon ablation (CBA). We aimed to explore the risk factors for the recurrence of AF after CBA in order to construct a nomogram that could predict this risk. Methods Data of 498 patients who had undergone CBA at Ruijin Hospital, Shanghai Jiaotong University School of Medicine, were retrospectively collected. Factors such as clinical characteristics and biophysical parameters during the CBA procedure were collected for the selection of variables. Scores for all the biophysical factors-such as time to pulmonary vein isolation (TTI) and balloon temperature-were calculated to enable construction of the model, which was then calibrated and compared with the risk scores. Results A 36-month follow-up showed that 177 (35.5%) of the 489 patients experienced AF recurrence. The left atrial volume, TTI, nadir cryoballoon temperature, and number of unsuccessful freezes were related to the recurrence of AF (P < .05). The area under the curve (AUC) of the nomogram's time-dependent receiver operating characteristic curve was 77.6%, 71.6%, and 71.0%, respectively, for the 1-, 2-, and 3-year prediction of recurrence in the training cohort and 77.4%, 74.7%, and 68.7%, respectively, for the same characteristics in the validation cohort. Calibration and data on the nomogram's clinical effectiveness showed it to be accurate for the prediction of recurrence in both the training and validation cohorts as compared with established risk scores. Conclusion Biophysical parameters such as TTI and cryoballoon temperature have a great impact on AF recurrence. The predictive accuracy for recurrence of our nomogram was superior to that of conventional risk scores.
Collapse
Affiliation(s)
| | | | | | | | | | - Ning Zhang
- Department of Cardiovascular Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Liqun Wu
- Department of Cardiovascular Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
6
|
Cecchini F, Mugnai G, Kazawa S, Bolzan B, Iacopino S, Maj R, Placentino F, Ribichini F, Sieira J, Sofianos D, Sorgente A, Tomasi L, de Asmundis C, Chierchia GB. Cryoballoon ablation for atrial fibrillation in octogenarians: a propensity score-based analysis with a younger cohort. J Cardiovasc Med (Hagerstown) 2023; 24:441-452. [PMID: 37285275 DOI: 10.2459/jcm.0000000000001486] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
BACKGROUND In terms of safety and efficacy, cryoballoon ablation (CB-A) has become a valid option for achieving pulmonary vein isolation (PVI) in patients affected by symptomatic atrial fibrillation. However, CB-A data in octogenarians are still scarce and limited to single-centre experiences. The present multicentre study aimed to compare the outcomes and complications of index CB-A in patients older than 80 years with a cohort of younger patients. METHODS AND RESULTS We retrospectively enrolled 97 consecutive patients aged ≥80 years who underwent PVI using the second-generation CB-A. This group was compared with a younger cohort of patients using a 1:1 propensity score matching. After the matching, 70 patients from the elderly group were analysed and compared with 70 younger patients (control group). The mean age was 81.4 ± 1.9 years among octogenarians and 65.2 ± 10.2 years in the younger cohort. The global success rate after a median follow-up of 23 [18-32.5] months was 60.0% in the elderly group and 71.4% in the control group (P = 0.17). Phrenic nerve palsy was the most common complication occurring in a total of 11 patients (7.9%): in 6 (8.6%) patients in the elderly group and in 5 patients (7.1%) in the younger group (P = 0.51). Only two (1.4%) major complications occurred: one (1.4%) femoral artery pseudoaneurysm in the control group, which resolved with a tight groin bandage, and one (1.4%) case of urosepsis in the elderly group. Arrhythmia recurrence during the blanking period and the need for electrical cardioversion to restore sinus rhythm after PVI were found to be the only independent predictors of late arrhythmia relapses. CONCLUSIONS The present study showed that CB-A PVI is as feasible, safe and effective among appropriately selected octogenarians as it is in younger patients.
Collapse
Affiliation(s)
- Federico Cecchini
- Electrophysiology Unit, Maria Cecilia Hospital, Cotignola, RA, Italy
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | - Giacomo Mugnai
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Department of Medicine, Azienda Universitaria Ospedaliera Integrata Verona, Verona, Italy
| | - Shuichiro Kazawa
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | - Bruna Bolzan
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Department of Medicine, Azienda Universitaria Ospedaliera Integrata Verona, Verona, Italy
| | - Saverio Iacopino
- Electrophysiology Unit, Maria Cecilia Hospital, Cotignola, RA, Italy
| | - Riccardo Maj
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | | | - Flavio Ribichini
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Department of Medicine, Azienda Universitaria Ospedaliera Integrata Verona, Verona, Italy
| | - Juan Sieira
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | - Dimitrios Sofianos
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | - Antonio Sorgente
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | - Luca Tomasi
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Department of Medicine, Azienda Universitaria Ospedaliera Integrata Verona, Verona, Italy
| | - Carlo de Asmundis
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| | - Gian-Battista Chierchia
- Heart Rhythm Management Center, Postgraduate program in Cardiac Electrophysiology and Pacing, European reference Networks Guard-Heart, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, Jette, Belgium
| |
Collapse
|
7
|
Canpolat U. Reconduction (reconnection or gap) after pulmonary vein isolation for paroxysmal atrial fibrillation ablation is a multifactorial process rather than a battle of fire and ice alone! J Cardiovasc Electrophysiol 2023; 34:1326-1328. [PMID: 36786512 DOI: 10.1111/jce.15857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 02/07/2023] [Indexed: 02/15/2023]
Affiliation(s)
- Ugur Canpolat
- Department of Cardiology, Arrhythmia and Electrophysiology Unit, Hacettepe University Faculty of Medicine, Ankara, Turkey
| |
Collapse
|
8
|
Tsiachris D, Doundoulakis I, Antoniou CK, Pagkalidou E, Zafeiropoulos S, Kordalis A, Gatzoulis KA, Chierchia GB, de Asmundis C, Tsioufis K, Stefanadis C. Effectiveness and safety of a time to isolation strategy of cryoballoon ablation of atrial fibrillation: A systematic review and meta-analysis. J Cardiovasc Electrophysiol 2022; 33:2640-2648. [PMID: 36177697 DOI: 10.1111/jce.15697] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2022] [Revised: 08/10/2022] [Accepted: 09/05/2022] [Indexed: 12/15/2022]
Abstract
AIM We conducted a systematic review and meta-analysis of randomized and observational studies with a control group to evaluate the effectiveness and safety of a time to isolation (TTI)-based strategy of cryoballoon ablation (CBA) in the treatment of atrial fibrillation (AF). METHODS Three electronic databases (MEDLINE, Cochrane Central Register of Controlled Trials, and Embase) without language restrictions were searched. The intervention assessed was a TTI-based strategy of CBA in the treatment of AF. TTI was defined as the time from the start of freezing to the last recorded pulmonary veins' potential. The comparison of interest was intended conventional protocol of CBA. The primary endpoint was freedom from atrial arrhythmia. RESULTS Nine studies were deemed eligible (N = 2289 patients). Eight studies reported freedom from atrial arrhythmia and pooled results showed a marginally similar success rate between the two protocols (odds ratio [OR]: 1.24; 95% confidence interval [CI]: 0.98-1.56). A prespecified subgroup analysis verified that a high dose TTI strategy (with >120 s duration of cryotherapy post-TTI) compared to the conventional protocol could significantly increase the patients without atrial arrhythmia during follow-up (OR: 1.39; 95% CI: 1.05-1.83). TTI strategy could also significantly decrease total procedure time (SMD: -26.24 min; 95% CI: -36.90 to -15.57) and phrenic nerve palsy incidence (OR: 0.49; 95% CI: 0.29-0.84). CONCLUSION Moderate confidence evidence suggests that an individualized CBA dosing strategy based on TTI and extended (>2 min post-TTI) duration of CBA is accompanied by fewer recurrences post-AF ablation.
Collapse
Affiliation(s)
| | - Ioannis Doundoulakis
- Athens Heart Center, Athens Medical Center, Athens, Greece.,First Department of Cardiology, "Hippokration" Hospital, National and Kapodistrian University, Athens, Greece
| | | | - Eirini Pagkalidou
- Department of Hygiene, Social-Preventive Medicine & Medical Statistics, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Stefanos Zafeiropoulos
- Elmezzi Graduate School of Molecular Medicine, Northwell Health, Manhasset, New York, USA.,Feinstein Institutes for Medical Research at Northwell Health, Manhasset, New York, USA
| | - Athanasios Kordalis
- Athens Heart Center, Athens Medical Center, Athens, Greece.,First Department of Cardiology, "Hippokration" Hospital, National and Kapodistrian University, Athens, Greece
| | - Konstantinos A Gatzoulis
- First Department of Cardiology, "Hippokration" Hospital, National and Kapodistrian University, Athens, Greece
| | - Gian-Battista Chierchia
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Carlo de Asmundis
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
| | - Konstantinos Tsioufis
- First Department of Cardiology, "Hippokration" Hospital, National and Kapodistrian University, Athens, Greece
| | - Christodoulos Stefanadis
- Athens Heart Center, Athens Medical Center, Athens, Greece.,Section of Cardiovascular Medicine, Yale University School of Medicine, New Haven, Connecticut, USA
| |
Collapse
|
9
|
Cecchini F, Mugnai G, Iacopino S, Abugattas JP, Adriaenssens B, Al-Housari M, Almorad A, Bala G, Bisignani A, de Asmundis C, De Greef Y, Maj R, Osòrio TG, Pannone L, Schwagten B, Sieira J, Sorgente A, Stroker E, Wolf M, Chierchia GB. Safety and long-term efficacy of cryoballoon ablation for atrial fibrillation in octogenarians: a multicenter experience. J Interv Card Electrophysiol 2022; 65:559-571. [DOI: 10.1007/s10840-022-01313-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 07/18/2022] [Indexed: 11/28/2022]
|