1
|
Zhu Q, Kakhi M, Jayasundara C, Walenga R, Behara SRB, Chan HK, Yang R. CFD-DEM investigation of the effects of aperture size for a capsule-based dry powder inhaler. Int J Pharm 2023; 647:123556. [PMID: 37890648 DOI: 10.1016/j.ijpharm.2023.123556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 10/02/2023] [Accepted: 10/24/2023] [Indexed: 10/29/2023]
Abstract
Capsule based dry powder inhalers (DPIs) often require piercing of the capsule before inhalation, and the characteristics of the apertures (punctured holes) affect air flow and the release of powders from the capsule. This work develops a numerical model based on the two-way coupling of computational fluid dynamics and discrete element method (CFD-DEM) to investigate the effect of aperture size on powder dispersion in the Aerolizer® device loaded with only carrier particles (lactose). Powders (carrier particles) in the size range 60-140 μm (d50: 90 μm and span: 0.66) were initialized in a capsule which had a circular aperture at each end. Boundary conditions corresponding to an air flow rate of 45 L/min were specified at each inlet to the mixing chamber (i.e., a total flow rate 90 L/min), and a capsule spin speed of ∼ 4050 rpm. The velocity magnitudes inside the capsule were considerably lower than those in the mixing chamber in the vicinity of the rotating capsule, with the exception of the capsules featuring 2.5 mm and 4 mm apertures. Larger apertures reduced the capsule emptying time and increased the particle evacuation velocity; the fluid drag force on the particles issuing from the capsule peaked for an aperture of 1.3 mm. Inside the capsule, particle-particle (PP) collisions were more frequent than particle-wall (PW) collisions due to high concentration of powder, but PP collisions had smaller (median) impact energy than PW collisions. Larger apertures resulted in fewer collisions in the capsule with higher PW and virtually unchanged PP collision energies. Outside the capsule (i.e., in the inhaler mixing chamber), PW collisions occurred more frequently than PP collisions with median collision energies typically two orders of magnitude higher than inside the capsule. Larger apertures resulted in more collisions with slightly reduced collision energy, but this effect plateaued for aperture sizes larger than 1.3 mm. Powder dispersion, expressed as the fine particle fraction (FPF) of the powder, was predicted using an empirical equation based on carrier PW collisions. Therefore, consistent with the model prediction of the effect of aperture sizes on the chamber collision frequency, FPF increased with aperture size but plateaued beyond 1.3 mm.
Collapse
Affiliation(s)
- Qixuan Zhu
- School of Materials Science and Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Maziar Kakhi
- Division of Product Quality Research, Office of Testing and Research, Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Chandana Jayasundara
- School of Materials Science and Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Ross Walenga
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Srinivas Ravindra Babu Behara
- Division of Immediate and Modified Release Products III, Office of Lifecycle Drug Products, Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Hak-Kim Chan
- Advanced Drug Delivery Group, School of Pharmacy, The University of Sydney, NSW 2006, Australia
| | - Runyu Yang
- School of Materials Science and Engineering, University of New South Wales, Sydney, NSW 2052, Australia.
| |
Collapse
|
2
|
Banat H, Ambrus R, Csóka I. Drug combinations for inhalation: Current products and future development addressing disease control and patient compliance. Int J Pharm 2023; 643:123070. [PMID: 37230369 DOI: 10.1016/j.ijpharm.2023.123070] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Revised: 05/07/2023] [Accepted: 05/21/2023] [Indexed: 05/27/2023]
Abstract
Pulmonary delivery is an alternative route of administration with numerous advantages over conventional routes of administration. It provides low enzymatic exposure, fewer systemic side effects, no first-pass metabolism, and concentrated drug amounts at the site of the disease, making it an ideal route for the treatment of pulmonary diseases. Owing to the thin alveolar-capillary barrier, and large surface area that facilitates rapid absorption to the bloodstream in the lung, systemic delivery can be achieved as well. Administration of multiple drugs at one time became urgent to control chronic pulmonary diseases such as asthma and COPD, thus, development of drug combinations was proposed. Administration of medications with variable dosages from different inhalers leads to overburdening the patient and may cause low therapeutic intervention. Therefore, products that contain combined drugs to be delivered via a single inhaler have been developed to improve patient compliance, reduce different dose regimens, achieve higher disease control, and boost therapeutic effectiveness in some cases. This comprehensive review aimed to highlight the growth of drug combinations by inhalation over time, obstacles and challenges, and the possible progress to broaden the current options or to cover new indications in the future. Moreover, various pharmaceutical technologies in terms of formulation and device in correlation with inhaled combinations were discussed in this review. Hence, inhaled combination therapy is driven by the need to maintain and improve the quality of life for patients with chronic respiratory diseases; promoting drug combinations by inhalation to a higher level is a necessity.
Collapse
Affiliation(s)
- Heba Banat
- Institute of Pharmaceutical Technology and Regulatory Affairs, Faculty of Pharmacy, University of Szeged, Hungary
| | - Rita Ambrus
- Institute of Pharmaceutical Technology and Regulatory Affairs, Faculty of Pharmacy, University of Szeged, Hungary
| | - Ildikó Csóka
- Institute of Pharmaceutical Technology and Regulatory Affairs, Faculty of Pharmacy, University of Szeged, Hungary.
| |
Collapse
|
3
|
Tang P, Kakhi M, Albariqi A, Ravindra Babu Behara S, Walenga R, Yang R, Chan HK. The role of capsule aperture size on the dispersion of carrier-based formulation at different air flowrates. Int J Pharm 2023:123152. [PMID: 37339687 DOI: 10.1016/j.ijpharm.2023.123152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 06/12/2023] [Accepted: 06/15/2023] [Indexed: 06/22/2023]
Abstract
The effect of capsule aperture size on the aerosol performance of lactose blend formulation was studied using Foradil® (containing 12 μg of formoterol fumarate (FF1) and 24 mg of lactose) dispersed with a powder inhaler Aerolizer® at increasing air flowrates. Apertures sizes of 0.4, 1.0, 1.5, 2.5, and 4.0 mm were introduced at the opposite ends of the capsule. The formulation was dispersed into a Next Generation Impactor (NGI) at 30, 60 and 90 L/min, with the fine particle fractions (FPFrec and FPFem) measured by chemical assay of FF and lactose using high-performance liquid chromatography. Particle size distribution (PSD) of FF particles dispersed in wet media was also characterized by laser diffraction. FPFrec showed a stronger dependency on the flowrate than the capsule aperture size. The most efficient dispersion was achieved at 90 L/min. At a given flowrate, FPFem remained broadly constant across different aperture sizes. The laser diffraction studies demonstrated the presence of large agglomerates.
Collapse
Affiliation(s)
- Patricia Tang
- Sydney Pharmacy School, The University of Sydney, Sydney, New South Wales, Australia
| | - Maziar Kakhi
- Division of Product Quality Research, Office of Testing and Research, Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, MD, USA
| | - Ahmed Albariqi
- Sydney Pharmacy School, The University of Sydney, Sydney, New South Wales, Australia
| | - Srinivas Ravindra Babu Behara
- Division of Immediate and Modified Release Products III, Office of Lifecycle Drug Products, Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, MD, USA
| | - Ross Walenga
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, MD, USA
| | - Runyu Yang
- School of Materials Science and Engineering, The University of New South Wales, Sydney, New South Wales, Australia
| | - Hak-Kim Chan
- Sydney Pharmacy School, The University of Sydney, Sydney, New South Wales, Australia.
| |
Collapse
|
4
|
Zhang Y, Hubert P, Hubert C. Investigation of potential substandard dry powder inhalers on EU and North African markets – evaluation of the delivered and fine particle doses. J Drug Assess 2022; 11:20-25. [PMID: 36213210 PMCID: PMC9543106 DOI: 10.1080/21556660.2022.2125727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Purpose Discovery of falsified Symbicort 320/9 Turbohaler identified in the UK in 2013 demonstrated that falsified dry powder inhalers were also present in the European market. This work aimed to investigate the current situation of formoterol-containing dry powder inhalers in Europe and North Africa by assessing their aerodynamic performance profile. Methods A total of eight registered formoterol-based dry powder inhalers over the European and North African markets were involved in this study, including the reference drug Foradil. Samples were prepared using a multistage liquid impinger (MsLI) and further analyzed by a validated HPLC-UV method to determine the delivered and the fine particle doses (FPDs). This study also examined the impact of freezing-thawing cycles on sample stability in terms of analytical purpose handling. Results No substandard dry powder inhalers were identified among the medicinal products involved in this work. The delivered dose (DD) of assessed drugs varied from 8.33 to 9.69 µg, while the FPD was between 1.86 and 3.35 µg. As expected, this work confirmed that the capsule composition and the barrier properties of the primary packaging can affect the FPD of dry powder for inhalation use. Conclusions The FPD of products C and B was, respectively, 17.4 and 14.2% superior to Foradil, products D and H had the closest values compared to the original drug, and product F was 34.5% inferior. Additionally, this work showed that a high FPD can be achieved using HPMC capsules and moisture-impermeable primary packaging.
Collapse
Affiliation(s)
- Yue Zhang
- Laboratory of Pharmaceutical Analytical Chemistry, CIRM, University of Liege (ULiege), Liege, Belgium
| | - Philippe Hubert
- Laboratory of Pharmaceutical Analytical Chemistry, CIRM, University of Liege (ULiege), Liege, Belgium
| | - Cédric Hubert
- Laboratory of Pharmaceutical Analytical Chemistry, CIRM, University of Liege (ULiege), Liege, Belgium
| |
Collapse
|
5
|
Buttini F, Quarta E, Allegrini C, Lavorini F. Understanding the Importance of Capsules in Dry Powder Inhalers. Pharmaceutics 2021; 13:pharmaceutics13111936. [PMID: 34834351 PMCID: PMC8623721 DOI: 10.3390/pharmaceutics13111936] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 10/27/2021] [Accepted: 11/06/2021] [Indexed: 11/16/2022] Open
Abstract
Pulmonary drug delivery is currently the focus of research and development because of its potential to produce maximum therapeutic benefit to patients by directing the drug straight to the lung disease site. Among all the available delivery options, one popular, proven and convenient inhaler device is the capsule-based dry powder inhaler (cDPI) for the treatment of an increasingly diverse range of diseases. cDPIs use a hard capsule that contains a powder formulation which consists of a mixture of a micronized drug and a carrier usually the lactose, known for its good lung tolerance. The capsule is either inserted into the device during manufacturer or by the patient prior to use. After perforating, opening or cut the capsule in the device, patients take a deep and rapid breath to inhale the powder, using air as the vector of drug displacement. The system is simple, relatively cheap and characterized by a lower carbon footprint than that of pressurized metered dose inhalers. This article reviews cDPI technology, focusing particularly on the importance of capsule characteristics and their function as a drug reservoir in cDPIs.
Collapse
Affiliation(s)
- Francesca Buttini
- Food and Drug Department, University of Parma, Parco Area delle Scienze 27/A, 43124 Parma, Italy;
- Correspondence: ; Tel.: +39-0521-906008
| | - Eride Quarta
- Food and Drug Department, University of Parma, Parco Area delle Scienze 27/A, 43124 Parma, Italy;
| | - Chiara Allegrini
- Department of Experimental and Clinical Medicine, University of Florence, Largo Brambilla 3, 50134 Florence, Italy; (C.A.); (F.L.)
| | - Federico Lavorini
- Department of Experimental and Clinical Medicine, University of Florence, Largo Brambilla 3, 50134 Florence, Italy; (C.A.); (F.L.)
| |
Collapse
|
6
|
Otake H, Minami M, Yamaguchi M, Akiyama S, Inaba K, Nagai N. Effect of inner physical properties on powder adhesion in inhalation capsules in case of a high resistance device. Exp Ther Med 2021; 22:1353. [PMID: 34659499 PMCID: PMC8515541 DOI: 10.3892/etm.2021.10788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Accepted: 08/20/2021] [Indexed: 11/09/2022] Open
Abstract
The inhalation performance of a dry powder inhaler (DPI) depends on the inhalation patterns of patients, inhalation particle characteristics and inhalation devices. In capsule-based DPIs, the capsule plays an important role in the dispersion of inhalation particles. The present study investigated the effects of inner physical properties of capsules on drug release from capsules-based DPIs with high resistance device. Atomic force microscopy (AFM) was used to evaluate the capsule physical properties, such as the capsule inner structure and surface potential, of three capsules with different compositions (G-Cap, PEG/G-Cap, and HPMC-Cap). As a model dry powder for capsule-based DPIs, the dry powder in Spiriva® Inhalation Capsules containing tiotropium bromide was used. Inhalation performance was evaluated using a twin-stage liquid impinge and Handihaler® (flow rate 30 l/min). The results indicated that the capsule inner surface presented with numerous valleys and mountains, regardless of the capsule type. Furthermore, the valley and mountain areas on the capsule inner surface showed a significantly higher or lower surface potential. Following inhalation of capsule-based DPIs, the drug remained in the valleys on the capsule inner surface; however, no significant difference was observed in the drug release from capsule and lung drug delivery. Therefore, inhalation performance in capsule-based DPIs when a high resistance device, such as Handihaler®, is used at an appropriately flow rate is not markedly affected by the physical properties of the capsule inner surface due to capsule composition.
Collapse
Affiliation(s)
- Hiroko Otake
- Faculty of Pharmacy, Kindai University, Higashi-Osaka, Osaka 577-8502, Japan
| | - Misa Minami
- Faculty of Pharmacy, Kindai University, Higashi-Osaka, Osaka 577-8502, Japan
| | - Mizuki Yamaguchi
- Faculty of Pharmacy, Kindai University, Higashi-Osaka, Osaka 577-8502, Japan
| | - Sawako Akiyama
- Faculty of Pharmacy, Kindai University, Higashi-Osaka, Osaka 577-8502, Japan
| | - Kazunori Inaba
- Faculty of Pharmacy, Kindai University, Higashi-Osaka, Osaka 577-8502, Japan
| | - Noriaki Nagai
- Faculty of Pharmacy, Kindai University, Higashi-Osaka, Osaka 577-8502, Japan
| |
Collapse
|
7
|
Ding L, Brunaugh AD, Stegemann S, Jermain SV, Herpin MJ, Kalafat J, Smyth HDC. A Quality by Design Framework for Capsule-Based Dry Powder Inhalers. Pharmaceutics 2021; 13:1213. [PMID: 34452174 PMCID: PMC8399055 DOI: 10.3390/pharmaceutics13081213] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Revised: 07/29/2021] [Accepted: 08/02/2021] [Indexed: 12/17/2022] Open
Abstract
Capsule-based dry powder inhalers (cDPIs) are widely utilized in the delivery of pharmaceutical powders to the lungs. In these systems, the fundamental nature of the interactions between the drug/formulation powder, the capsules, the inhaler device, and the patient must be fully elucidated in order to develop robust manufacturing procedures and provide reproducible lung deposition of the drug payload. Though many commercially available DPIs utilize a capsule-based dose metering system, an in-depth analysis of the critical factors associated with the use of the capsule component has not yet been performed. This review is intended to provide information on critical factors to be considered for the application of a quality by design (QbD) approach for cDPI development. The quality target product profile (QTPP) defines the critical quality attributes (CQAs) which need to be understood to define the critical material attributes (CMA) and critical process parameters (CPP) for cDPI development as well as manufacturing and control.
Collapse
Affiliation(s)
- Li Ding
- Division of Molecular Pharmaceutics and Drug Delivery, College of Pharmacy, The University of Texas at Austin, Austin, TX 78712, USA; (L.D.); (A.D.B.); (S.V.J.); (M.J.H.)
| | - Ashlee D. Brunaugh
- Division of Molecular Pharmaceutics and Drug Delivery, College of Pharmacy, The University of Texas at Austin, Austin, TX 78712, USA; (L.D.); (A.D.B.); (S.V.J.); (M.J.H.)
| | - Sven Stegemann
- Institute for Process and Particle Engineering, Graz University of Technology, 8010 Graz, Austria;
| | - Scott V. Jermain
- Division of Molecular Pharmaceutics and Drug Delivery, College of Pharmacy, The University of Texas at Austin, Austin, TX 78712, USA; (L.D.); (A.D.B.); (S.V.J.); (M.J.H.)
| | - Matthew J. Herpin
- Division of Molecular Pharmaceutics and Drug Delivery, College of Pharmacy, The University of Texas at Austin, Austin, TX 78712, USA; (L.D.); (A.D.B.); (S.V.J.); (M.J.H.)
| | - Justin Kalafat
- ACG North America, LLC, 262 Old New Brunswick Road, Suite A, Piscataway, NJ 08854, USA;
| | - Hugh D. C. Smyth
- Division of Molecular Pharmaceutics and Drug Delivery, College of Pharmacy, The University of Texas at Austin, Austin, TX 78712, USA; (L.D.); (A.D.B.); (S.V.J.); (M.J.H.)
| |
Collapse
|
8
|
Stability and In Vitro Aerodynamic Studies of Inhalation Powders Containing Ciprofloxacin Hydrochloride Applying Different DPI Capsule Types. Pharmaceutics 2021; 13:pharmaceutics13050689. [PMID: 34064698 PMCID: PMC8151261 DOI: 10.3390/pharmaceutics13050689] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Revised: 05/03/2021] [Accepted: 05/06/2021] [Indexed: 11/17/2022] Open
Abstract
In the case of capsule-based dry powder inhalation systems (DPIs), the selection of the appropriate capsule is important. The use of gelatin, gelatin-PEG, and HPMC capsules has become widespread in marketed capsule-based DPIs. We aimed to perform a stability test according to the ICH guideline in the above-mentioned three capsule types. The results of the novel combined formulated microcomposite were more favorable than those of the carrier-free formulation for all capsule types. The use of HPMC capsules results in the greatest stability and thus the best in vitro aerodynamic results for both DPI powders after six months. This can be explained by the fact that the residual solvent content (RSC) of the capsules differs. Under the applied conditions the RSC of the HPMC capsule decreased the least and remained within the optimal range, thus becoming less fragmented, which was reflected in the RSC, structure and morphology of the particles, as well as in the in vitro aerodynamic results (there was a difference of approximately 10% in the lung deposition results). During pharmaceutical dosage form developments, emphasis should be placed in the case of DPIs on determining which capsule type will be used for specific formulations.
Collapse
|
9
|
Pinto JT, Wutscher T, Stankovic-Brandl M, Zellnitz S, Biserni S, Mercandelli A, Kobler M, Buttini F, Andrade L, Daza V, Ecenarro S, Canalejas L, Paudel A. Evaluation of the Physico-mechanical Properties and Electrostatic Charging Behavior of Different Capsule Types for Inhalation Under Distinct Environmental Conditions. AAPS PharmSciTech 2020; 21:128. [PMID: 32399597 PMCID: PMC7217808 DOI: 10.1208/s12249-020-01676-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Accepted: 04/04/2020] [Indexed: 02/07/2023] Open
Abstract
Capsule-based dry powder inhaler (DPI) products can be influenced by a multitude of interacting factors, including electrostatic charging. Tribo-charging is a process of charge transfer impacted by various factors, i.e., material surface characteristics, mechanical properties, processing parameters and environmental conditions. Consequently, this work aimed to assess how the charging behavior of capsules intended for inhalation might be influenced by environmental conditions. Capsules having different chemical compositions (gelatin and hydroxypropyl methylcellulose (HPMC)) and distinct inherent characteristics from manufacturing (thermally and cold-gelled) were exposed to various environmental conditions (11%, 22% and 51% RH). Their resulting properties were characterized and tribo-charging behavior was measured against stainless steel and PVC. It was observed that all capsule materials tended to charge to a higher extent when in contact with PVC. The tribo-charging of the thermally gelled HPMC capsules (Vcaps® Plus) was more similar to the gelatin capsules (Quali-G™-I) than to their HPMC cold-gelled counterparts (Quali-V®-I). The sorption of water by the capsules at different relative humidities notably impacted their properties and tribo-charging behavior. Different interactions between the tested materials and water molecules were identified and are proposed to be the driver of distinct charging behaviors. Finally, we showed that depending on the capsule types, distinct environmental conditions are necessary to mitigate charging and assure optimal behavior of the capsules.
Collapse
|