1
|
Lee TF, Chang CH, Chi CH, Liu YH, Shao JC, Hsieh YW, Yang PY, Tseng CD, Chiu CL, Hu YC, Lin YW, Chao PJ, Lee SH, Yeh SA. Utilizing radiomics and dosiomics with AI for precision prediction of radiation dermatitis in breast cancer patients. BMC Cancer 2024; 24:965. [PMID: 39107701 PMCID: PMC11304569 DOI: 10.1186/s12885-024-12753-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Accepted: 08/02/2024] [Indexed: 08/10/2024] Open
Abstract
PURPOSE This study explores integrating clinical features with radiomic and dosiomic characteristics into AI models to enhance the prediction accuracy of radiation dermatitis (RD) in breast cancer patients undergoing volumetric modulated arc therapy (VMAT). MATERIALS AND METHODS This study involved a retrospective analysis of 120 breast cancer patients treated with VMAT at Kaohsiung Veterans General Hospital from 2018 to 2023. Patient data included CT images, radiation doses, Dose-Volume Histogram (DVH) data, and clinical information. Using a Treatment Planning System (TPS), we segmented CT images into Regions of Interest (ROIs) to extract radiomic and dosiomic features, focusing on intensity, shape, texture, and dose distribution characteristics. Features significantly associated with the development of RD were identified using ANOVA and LASSO regression (p-value < 0.05). These features were then employed to train and evaluate Logistic Regression (LR) and Random Forest (RF) models, using tenfold cross-validation to ensure robust assessment of model efficacy. RESULTS In this study, 102 out of 120 VMAT-treated breast cancer patients were included in the detailed analysis. Thirty-two percent of these patients developed Grade 2+ RD. Age and BMI were identified as significant clinical predictors. Through feature selection, we narrowed down the vast pool of radiomic and dosiomic data to 689 features, distributed across 10 feature subsets for model construction. In the LR model, the J subset, comprising DVH, Radiomics, and Dosiomics features, demonstrated the highest predictive performance with an AUC of 0.82. The RF model showed that subset I, which includes clinical, radiomic, and dosiomic features, achieved the best predictive accuracy with an AUC of 0.83. These results emphasize that integrating radiomic and dosiomic features significantly enhances the prediction of Grade 2+ RD. CONCLUSION Integrating clinical, radiomic, and dosiomic characteristics into AI models significantly improves the prediction of Grade 2+ RD risk in breast cancer patients post-VMAT. The RF model analysis demonstrates that a comprehensive feature set maximizes predictive efficacy, marking a promising step towards utilizing AI in radiation therapy risk assessment and enhancing patient care outcomes.
Collapse
Affiliation(s)
- Tsair-Fwu Lee
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Jiangong RdSanmin Dist., No.415, Kaohsiung, 80778, Taiwan, ROC
- Graduate Institute of Clinical Medicine, Kaohsiung Medical University, Kaohsiung, 807, Taiwan, ROC
- Department of Medical Imaging and Radiological Sciences, Kaohsiung Medical University, Kaohsiung, 80708, Taiwan, ROC
| | - Chu-Ho Chang
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Jiangong RdSanmin Dist., No.415, Kaohsiung, 80778, Taiwan, ROC
| | - Chih-Hsuan Chi
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Jiangong RdSanmin Dist., No.415, Kaohsiung, 80778, Taiwan, ROC
| | - Yen-Hsien Liu
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Jiangong RdSanmin Dist., No.415, Kaohsiung, 80778, Taiwan, ROC
| | - Jen-Chung Shao
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Jiangong RdSanmin Dist., No.415, Kaohsiung, 80778, Taiwan, ROC
| | - Yang-Wei Hsieh
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Jiangong RdSanmin Dist., No.415, Kaohsiung, 80778, Taiwan, ROC
| | - Pei-Ying Yang
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Jiangong RdSanmin Dist., No.415, Kaohsiung, 80778, Taiwan, ROC
| | - Chin-Dar Tseng
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Jiangong RdSanmin Dist., No.415, Kaohsiung, 80778, Taiwan, ROC
| | - Chien-Liang Chiu
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Jiangong RdSanmin Dist., No.415, Kaohsiung, 80778, Taiwan, ROC
| | - Yu-Chang Hu
- Department of Radiation Oncology, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan, ROC
| | - Yu-Wei Lin
- Department of Radiation Oncology, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan, ROC
| | - Pei-Ju Chao
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Jiangong RdSanmin Dist., No.415, Kaohsiung, 80778, Taiwan, ROC.
| | - Shen-Hao Lee
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Jiangong RdSanmin Dist., No.415, Kaohsiung, 80778, Taiwan, ROC.
- Department of Radiation Oncology, Linkou Chang Gung Memorial Hospitaland, Chang Gung University College of Medicine, Linkou, Taiwan, ROC.
| | - Shyh-An Yeh
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Science and Technology, Jiangong RdSanmin Dist., No.415, Kaohsiung, 80778, Taiwan, ROC.
- Department of Medical Imaging and Radiological Sciences, I-Shou University, Kaohsiung, 82445, Taiwan, ROC.
- Department of Radiation Oncology, E-DA Hospital, Kaohsiung, 82445, Taiwan, ROC.
| |
Collapse
|
2
|
Cicchetti A, Mangili P, Fodor A, Gabellini MGU, Chiara A, Deantoni C, Mori M, Pasetti M, Palazzo G, Rancati T, Del Vecchio A, Gisella Di Muzio N, Fiorino C. Skin dose-volume predictors of moderate-severe late side effects after whole breast radiotherapy. Radiother Oncol 2024; 194:110183. [PMID: 38423138 DOI: 10.1016/j.radonc.2024.110183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 02/17/2024] [Accepted: 02/20/2024] [Indexed: 03/02/2024]
Abstract
BACKGROUND Toxicity after whole breast Radiotherapy is a relevant issue, impacting the quality-of-life of a not negligible number of patients. We aimed to develop a Normal Tissue Complication Probability (NTCP) model predicting late toxicities by combining dosimetric parameters of the breast dermis and clinical factors. METHODS The skin structure was defined as the outer CT body contour's 5 mm inner isotropic expansion. It was retrospectively segmented on a large mono-institutional cohort of early-stage breast cancer patients enrolled between 2009 and 2017 (n = 1066). Patients were treated with tangential-field RT, delivering 40 Gy in 15 fractions to the whole breast. Toxicity was reported during Follow-Up (FU) using SOMA/LENT scoring. The study endpoint was moderate-severe late side effects consisting of Fibrosis-Atrophy-Telangiectasia-Pain (FATP G ≥ 2) developed within 42 months after RT completion. A machine learning pipeline was designed with a logistic model combining clinical factors and absolute skin DVH (cc) parameters as output. RESULTS The FATP G2 + rate was 3.8 %, with 40/1066 patients experiencing side effects. After the preprocessing of variables, a cross-validation was applied to define the best-performing model. We selected a 4-variable model with Post-Surgery Cosmetic alterations (Odds Ratio, OR = 7.3), Aromatase Inhibitors (as a protective factor with OR = 0.45), V20 Gy (50 % of the prescribed dose, OR = 1.02), and V42 Gy (105 %, OR = 1.09). Factors were also converted into an adjusted V20Gy. CONCLUSIONS The association between late reactions and skin DVH when delivering 40 Gy/15 fr was quantified, suggesting an independent role of V20 and V42. Few clinical factors heavily modulate the risk.
Collapse
Affiliation(s)
- Alessandro Cicchetti
- Fondazione IRCCS Istituto Nazionale dei Tumori di Milano, Data Science Unit, Milan, Italy.
| | - Paola Mangili
- IRCCS San Raffaele Scientific Institute, Medical Physics Milan, Italy
| | - Andrei Fodor
- IRCCS San Raffaele Scientific Institute, Radiotherapy, Milan, Italy
| | | | - Anna Chiara
- IRCCS San Raffaele Scientific Institute, Radiotherapy, Milan, Italy
| | - Chiara Deantoni
- IRCCS San Raffaele Scientific Institute, Radiotherapy, Milan, Italy
| | - Martina Mori
- IRCCS San Raffaele Scientific Institute, Medical Physics Milan, Italy
| | - Marcella Pasetti
- IRCCS San Raffaele Scientific Institute, Radiotherapy, Milan, Italy
| | - Gabriele Palazzo
- IRCCS San Raffaele Scientific Institute, Medical Physics Milan, Italy
| | - Tiziana Rancati
- Fondazione IRCCS Istituto Nazionale dei Tumori di Milano, Data Science Unit, Milan, Italy
| | | | | | - Claudio Fiorino
- IRCCS San Raffaele Scientific Institute, Medical Physics Milan, Italy
| |
Collapse
|
3
|
Baba MH, Singh BK, Wani SUQ. Skin Sparing in Intensity-Modulated Radiation Therapy of Nasopharyngeal Carcinoma. J Med Phys 2022; 47:243-249. [PMID: 36684702 PMCID: PMC9847000 DOI: 10.4103/jmp.jmp_27_22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 05/04/2022] [Accepted: 05/30/2022] [Indexed: 11/10/2022] Open
Abstract
Background and Purpose Radiation therapy of nasopharyngeal carcinomas (NPCs) involves high doses to the target structures which are superficial to the skin surfaces. As a result, the skin toxicities involved are higher and sometimes worsens to such an extent that radiotherapy needs to be interrupted unplanned. This leads to a break in radiation therapy which overall affects the local control and cure rates. The aim of this study is to decrease the skin dose by contouring skin as an organ at risk (OAR) to include in inverse planning calculation. Materials and Methods Seventy-three cases of nasopharyngeal cancers were planned for 60 Gy to intermediate-risk planning target volume (PTVIntermediate) and 70 Gy to high risk (PTVHigh), by three different modes of Intensity-modulated radiation therapy (IMRT)- namely conventional sequential intensity-modulated radiation therapy (S-IMRT PH-I and PH-II), Skin Spared sequential intensity-modulated radiation therapy (SS-IMRT PH-I and PH-II), and Skin Spared simultaneously instantaneous boost intensity-modulated radiation therapy (SS-SIB IMRT). The plans were compared by dose volume histograms and dose statistics to the PTV as well as to the OAR's. For PTV, mean dose (Dmean), maximum dose (Dmax), and minimum dose (Dmin) were compared to check the homogeneity index (HI) while sparing the skin. For other OAR's Dmean, Dmax and dose to to 1 cubic cm was used for comparison. The skin doses to various volumes from volume to receive 5 Gy (V5) to volume to receive 70 Gy (V70) were evaluated and compared between the three techniques. Statistical analysis was done using one away ANOVA on the data editor SPSS Version 26.0 (SPSS Inc., Chicago, Illinois, USA) to evaluate the results. Continuous variables were expressed as mean ± standard deviation, and categorical variables were summarized as frequencies and percentages. Survival analysis was done by Kaplan-Meier Estimator. Results When the skin was considered as an OAR, the skin volume to receive 5, 10, 15, 20, 30, 40, 50, 60, 70 Gy was reduced by 6.5%, 6.5%, 6%, 11.5%, 7%, 6%, 6%, 5%, 2%, respectively, by SS-IMRT PH-I and II and 2%, 4.05%, 4%, 7%, 5%, 3%, 6%, 5%, 1%, respectively, by SS-SIB IMRT when both the SS techniques were compared with S-IMRT PH-I and II. Volume of skin to receive 20 Gy showed maximum reduction in SS-IMRT PH-I and II. A one-way ANOVA was carried out to find the differences in the skin doses between the three techniques. The skin dose in the two SS techniques, i.e., SS-IMRT PH-I and PH-II and SS-SIB IMRT was found significantly lower than that of IMRT plans without skin as an OAR, i.e., S-IMRT PH-I and PH-II (P = 0.000). The PTV doses were well within the 95%-107% of the prescribed dose (HI) and there were no significant differences in the means of the prescribed dose between the simple and skin spared IMRT techniques. The other OARs doses were also evaluated and there were no significant differences between the means of the doses among the techniques. Conclusions SS IMRT for NPC has demonstrated reduction in skin dose while using skin as an OAR in the optimization. Moreover, decreased skin dose can decrease the skin related toxicities provided there is no compromise on Target dose coverage and OAR dose. We recommend that skin should be contoured as an OAR for NPC, provided PTV is minimally 3-5 mm beneath skin surface, in order to have a better disease control with lesser toxicities and less unplanned treatment interruptions.
Collapse
Affiliation(s)
- Misba Hamid Baba
- Department of Physics, Institute of Applied Sciences and Humanities, GLA University, Mathura, Uttar Pradesh, India
- Department of Radiological Physics and Bio-Engineering, Srinagar, Jammu and Kashmir, India
| | - Benoy K Singh
- Department of Physics, Institute of Applied Sciences and Humanities, GLA University, Mathura, Uttar Pradesh, India
| | - Shaq ul Qamar Wani
- Department of Radiation Oncology, Sher I Kashmir Institute of Medical Sciences, Srinagar, Jammu and Kashmir, India
| |
Collapse
|
4
|
Jagsi R, Griffith KA, Moran JM, Matuszak MM, Marsh R, Grubb M, Abu-Isa E, Dilworth JT, Dominello MM, Heimburger D, Lack D, Walker EM, Hayman JA, Vicini F, Pierce LJ. Comparative Effectiveness Analysis of 3D-Conformal Radiation Therapy Versus Intensity Modulated Radiation Therapy (IMRT) in a Prospective Multicenter Cohort of Patients With Breast Cancer. Int J Radiat Oncol Biol Phys 2022; 112:643-653. [PMID: 34634437 DOI: 10.1016/j.ijrobp.2021.09.053] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 09/22/2021] [Accepted: 09/30/2021] [Indexed: 11/24/2022]
Abstract
PURPOSE Simple intensity modulation of radiation therapy reduces acute toxicity compared with 2-dimensional techniques in adjuvant breast cancer treatment, but it remains unknown whether more complex or inverse-planned intensity modulated radiation therapy (IMRT) offers an advantage over forward-planned, 3-dimensional conformal radiation therapy (3DCRT). METHODS AND MATERIALS Using prospective data regarding patients receiving adjuvant whole breast radiation therapy without nodal irradiation at 23 institutions from 2011 to 2018, we compared the incidence of acute toxicity (moderate-severe pain or moist desquamation) in patients receiving 3DCRT versus IMRT (either inverse planned or, if forward-planned, using ≥5 segments per gantry angle). We evaluated associations between technique and toxicity using multivariable models with inverse-probability-of-treatment weighting, adjusting for treatment facility as a random effect. RESULTS Of 1185 patients treated with 3DCRT and conventional fractionation, 650 (54.9%) experienced acute toxicity; of 774 treated with highly segmented forward-planned IMRT, 458 (59.2%) did; and of 580 treated with inverse-planned IMRT, 245 (42.2%) did. Of 1296 patients treated with hypofractionation and 3DCRT, 432 (33.3%) experienced acute toxicity; of 709 treated with highly segmented forward-planned IMRT, 227 (32.0%) did; and of 623 treated with inverse-planned IMRT, 164 (26.3%) did. On multivariable analysis with inverse-probability-of-treatment weighting, the odds ratio for acute toxicity after inverse-planned IMRT versus 3DCRT was 0.64 (95% confidence interval, 0.45-0.91) with conventional fractionation and 0.41 (95% confidence interval, 0.26-0.65) with hypofractionation. CONCLUSIONS This large, prospective, multicenter comparative effectiveness study found a significant benefit from inverse-planned IMRT compared with 3DCRT in reducing acute toxicity of breast radiation therapy. Future research should identify the dosimetric differences that mediate this association and evaluate cost-effectiveness.
Collapse
Affiliation(s)
- Reshma Jagsi
- Department of Radiation Oncology, Medical School, University of Michigan, Ann Arbor, Michigan.
| | - Kent A Griffith
- Department of Biostatistics, University of Michigan, Ann Arbor, Michigan
| | - Jean M Moran
- Department of Radiation Oncology, Medical School, University of Michigan, Ann Arbor, Michigan
| | - Martha M Matuszak
- Department of Radiation Oncology, Medical School, University of Michigan, Ann Arbor, Michigan
| | - Robin Marsh
- Department of Radiation Oncology, Medical School, University of Michigan, Ann Arbor, Michigan
| | - Margaret Grubb
- Department of Radiation Oncology, Medical School, University of Michigan, Ann Arbor, Michigan
| | - Eyad Abu-Isa
- Department of Radiation Oncology, Medical School, University of Michigan, Ann Arbor, Michigan; Department of Radiation Oncology, Providence Ascension, Novi, Michigan
| | - Joshua T Dilworth
- Department of Radiation Oncology, Beaumont Health, Royal Oak, Michigan
| | - Michael M Dominello
- Department of Radiation Oncology, Karmanos Cancer Center, Wayne State University, Detroit, Michigan
| | - David Heimburger
- Department of Radiation Oncology, Munson Healthcare, Traverse City, Michigan
| | - Danielle Lack
- Department of Radiation Oncology, Beaumont Health, Royal Oak, Michigan
| | - Eleanor M Walker
- Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan
| | - James A Hayman
- Department of Radiation Oncology, Medical School, University of Michigan, Ann Arbor, Michigan
| | - Frank Vicini
- Department of Radiation Oncology, GenesisCare, Farmington Hills, Michigan
| | - Lori J Pierce
- Department of Radiation Oncology, Medical School, University of Michigan, Ann Arbor, Michigan
| |
Collapse
|
5
|
Moncion A, Wilson M, Ma R, Marsh R, Burmeister J, Dryden D, Lack D, Grubb M, Mayville A, Jursinic P, Dess K, Kamp J, Young K, Dilworth JT, Kestin L, Jagsi R, Mietzel M, Vicini F, Pierce LJ, Moran JM. Evaluation of Dose Accuracy in the Near-Surface Region for Whole Breast Irradiation Techniques in a Multi-Institutional Consortium. Pract Radiat Oncol 2022; 12:e317-e328. [DOI: 10.1016/j.prro.2022.01.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 11/02/2021] [Accepted: 01/10/2022] [Indexed: 11/29/2022]
|
6
|
Choi KH, Ahn SJ, Jeong JU, Yu M, Kim JH, Jeong BK, Lee JH, Kim SH, Lee JH. Postoperative radiotherapy with intensity-modulated radiation therapy versus 3-dimensional conformal radiotherapy in early breast cancer: A randomized clinical trial of KROG 15-03. Radiother Oncol 2020; 154:179-186. [PMID: 32980384 DOI: 10.1016/j.radonc.2020.09.043] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 09/17/2020] [Accepted: 09/21/2020] [Indexed: 11/29/2022]
Abstract
PURPOSE To investigate the safety and efficacy of intensity-modulated radiation therapy (IMRT) for early breast cancer compared with 3-dimensional conformal radiotherapy (3D-CRT) in a prospective and randomized trial. METHODS AND MATERIALS From March 2015 to February 2018, 693 patients with pT1-2N0M0 early breast cancer who underwent breast-conserving surgery were enrolled and randomly assigned into IMRT and 3D-CRT. The primary endpoint was 3-year locoregional recurrence-free survival (LRRFS). The secondary endpoints were recurrence-free survival, overall survival, acute toxicity, target coverage index, irradiation dose to organs at risk, and fatigue inventory. The radiation dose for the 3D-CRT arm was 59.4 Gy in 33 fractions for 6.5 weeks. It was 57.4 Gy in 28 fractions with simultaneous integrated boost for 5.5 weeks for the IMRT arm. RESULTS Of 693 patients, 349 and 344 patients received 3D-CRT and IMRT, respectively. There was no significant difference in LRRFS between the two arms. Conformity index of planning target volume was significantly superior in the IMRT arm than the 3D-CRT arm (p < 0.001). The mean lung dose and V5-V50 for the ipsilateral lung were significantly lower in the IMRT arm than the 3D-CRT arm (all p < 0.05). The incidence of grade 2 or higher dermatitis was significantly lower in the IMRT arm (p = 0.009). CONCLUSION Compared to 3D-CRT, IMRT showed similar results in locoregional tumor control but superior results in planning target volume coverage. When IMRT is used in breast cancer, the irradiation dose to an ipsilateral lung and skin toxicity can be reduced.
Collapse
Affiliation(s)
- Kyu Hye Choi
- Department of Radiation Oncology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Sung Ja Ahn
- Department of Radiation Oncology, Chonnam National University Hospital, Chonnam National University School of Medicine, Gwangju, Republic of Korea
| | - Jae Uk Jeong
- Department of Radiation Oncology, Chonnam National University Hospital, Chonnam National University School of Medicine, Gwangju, Republic of Korea
| | - Mina Yu
- Department of Radiation Oncology, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Jin Hee Kim
- Department of Radiation Oncology, Dongsan Medical Center, Keimyung University School of Medicine, Daegu, Republic of Korea
| | - Bae Kwon Jeong
- Department of Radiation Oncology, Gyeongsang National University Hospital, Gyeongsang National University School of Medicine, Jinju, Republic of Korea
| | - Joo Hwan Lee
- Department of Radiation Oncology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Sung Hwan Kim
- Department of Radiation Oncology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Jong Hoon Lee
- Department of Radiation Oncology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
| |
Collapse
|
7
|
Joseph K, Vos LJ, Gabos Z, Pervez N, Chafe S, Tankel K, Warkentin H, Ghosh S, Amanie J, Powell K, Polkosnik LA, Horsman S, MacKenzie M, Sabri S, Parliament MB, Mackey J, Abdulkarim B. Skin Toxicity in Early Breast Cancer Patients Treated with Field-In-Field Breast Intensity-Modulated Radiotherapy versus Helical Inverse Breast Intensity-Modulated Radiotherapy: Results of a Phase III Randomised Controlled Trial. Clin Oncol (R Coll Radiol) 2020; 33:30-39. [PMID: 32711920 DOI: 10.1016/j.clon.2020.07.005] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Revised: 06/08/2020] [Accepted: 07/03/2020] [Indexed: 11/15/2022]
Abstract
AIMS Skin toxicity is a common adverse effect of breast radiotherapy. We investigated whether inverse-planned intensity-modulated radiotherapy (IMRT) would reduce the incidence of skin toxicity compared with forward field-in-field breast IMRT (FiF-IMRT) in early stage breast cancer. MATERIALS AND METHODS This phase III randomised controlled trial compared whole-breast irradiation with either FiF-IMRT or helical tomotherapy IMRT (HT-IMRT), with skin toxicity as the primary end point. Patients received 50 Gy in 25 fractions and were assessed to compare skin toxicity between treatment arms. RESULTS In total, 177 patients were available for assessment and the median follow-up was 73.1 months. Inverse IMRT achieved more homogeneous coverage than FiF-IMRT; erythema and moist desquamation were higher with FiF-IMRT compared with HT-IMRT (61% versus 34%; P < 0.001; 33% versus 11%; P < 0.001, respectively). Multivariate analysis showed large breast volume, FiF-IMRT and chemotherapy were independent factors associated with worse acute toxicity. There was no difference between treatment arms in the incidence of late toxicities. The 5-year recurrence-free survival was 96.3% for both FiF-IMRT and HT-IMRT and the 5-year overall survival was 96.3% for FiF-IMRT and 97.4% for HT-IMRT. CONCLUSIONS Our study showed significant reduction in acute skin toxicity using HT-IMRT compared with FiF-IMRT, without significant reduction in late skin toxicities. On the basis of these findings, inverse-planned IMRT could be used in routine practice for whole-breast irradiation with careful plan optimisation to achieve the required dose constraints for organs at risk.
Collapse
Affiliation(s)
- K Joseph
- Division of Radiation Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - L J Vos
- Alberta Cancer Clinical Trials, Cross Cancer Institute, Edmonton, Alberta, Canada
| | - Z Gabos
- Division of Radiation Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - N Pervez
- Division of Radiation Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - S Chafe
- Division of Radiation Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - K Tankel
- Division of Radiation Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - H Warkentin
- Division of Medical Physics, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - S Ghosh
- Division of Medical Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - J Amanie
- Division of Radiation Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - K Powell
- Division of Medical Physics, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - L-A Polkosnik
- Division of Medical Physics, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - S Horsman
- Division of Medical Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - M MacKenzie
- Division of Medical Physics, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - S Sabri
- Division of Experimental Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - M B Parliament
- Division of Radiation Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - J Mackey
- Division of Medical Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada
| | - B Abdulkarim
- Division of Radiation Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada.
| |
Collapse
|
8
|
Borm KJ, Loos M, Oechsner M, Mayinger MC, Paepke D, Kiechle MB, Combs SE, Duma MN. Acute radiodermatitis in modern adjuvant 3D conformal radiotherapy for breast cancer - the impact of dose distribution and patient related factors. Radiat Oncol 2018; 13:218. [PMID: 30404664 PMCID: PMC6223003 DOI: 10.1186/s13014-018-1160-5] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Accepted: 10/22/2018] [Indexed: 12/20/2022] Open
Abstract
Purpose This study was performed to evaluate skin toxicity during modern three-dimensional conformal radiotherapy (3D-CRT) and to evaluate the importance of dose distribution and patient related factors. Material and methods This study comprises 255 patients with breast cancer treated with tangential three-dimensional conformal radiotherapy (3D-CRT) after breast conserving surgery between 03/2012 and 05/2017. The median prescribed dose was 50.4 Gy (range 50–50.4) and 92.2% of the patients received a sequential boost of 10–16 Gy. Adverse skin toxicities (according to CTCAE v. 4.03 and the occurrence of moist desquamations) were assessed at the end of treatment. The dose distribution in the skin (5 mm strip from the patient outline) and in the CTV was evaluated and correlated to the CTCAE scores and the occurrence of moist desquamation. Results 42.4% of the patients developed grade I, 55.7% grade II and 2% grade III skin toxicities. Moist desquamation was observed in 59 cases (23.1%). Dose distribution within the CTV and skin was homogenous with only small areas receiving 107% of the prescribed dose (median: 0.7 cm3) in the CTV and 105% (median 0.5 cm3) in the skin. On univariate analysis breast size as well as V107%(CTV), V105%(skin) and V80%(skin) correlated significantly (p < 0.05) with the incidence of skin toxicity. On multivariate analysis only V80%(skin) was confirmed as independent risk factor. Conclusion Modern tangential multi-field 3D-CRT allows a homogeneous dose distribution with similar skin toxicity as compared to studies performing IMRT. Dose distribution within the skin (V80%) might have a relevant impact on the severity of skin toxicity and the occurrence of moist desquamation.
Collapse
Affiliation(s)
- Kai J Borm
- Department of Radiotherapy, Klinikum Rechts der Isar, Technical University, Munich, Germany
| | | | - Markus Oechsner
- Department of Radiotherapy, Klinikum Rechts der Isar, Technical University, Munich, Germany
| | - Michael C Mayinger
- Department of Radiotherapy, Klinikum Rechts der Isar, Technical University, Munich, Germany
| | - Daniela Paepke
- Department of Gynecology and Obstetrics, Klinikum Rechts der Isar, Technical University, Munich, Germany
| | - Marion B Kiechle
- Department of Gynecology and Obstetrics, Klinikum Rechts der Isar, Technical University, Munich, Germany
| | - Stephanie E Combs
- Department of Radiotherapy, Klinikum Rechts der Isar, Technical University, Munich, Germany.,Deutsches Konsortium für Translationale Krebsforschung (DKTK)-Partner Site Munich, 81675, Munich, Germany.,Institute of Innovative Radiohterapy, Helmholtzzentrum München, Munich, Germany
| | - Marciana N Duma
- Department of Radiotherapy, Klinikum Rechts der Isar, Technical University, Munich, Germany. .,Institute of Innovative Radiohterapy, Helmholtzzentrum München, Munich, Germany. .,Department of Radiation Oncology, Klinikum rechts der Isar/ TU Munchen, Ismaninger Strasse 22, 81675, Munchen, Germany.
| |
Collapse
|
9
|
Gopalakrishnan Z, Nair RK, Raghukumar P, Sarin B. Dosimetric Comparison of Treatment Plans Using Physical Wedge and Enhanced Dynamic Wedge for the Planning of Breast Radiotherapy. J Med Phys 2018; 43:46-51. [PMID: 29628633 PMCID: PMC5879823 DOI: 10.4103/jmp.jmp_40_17] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
The aim of this study is to compare the physical wedge (PW) with enhanced dynamic wedge (EDW) to determine the difference in the dose distribution affecting the treated breast and the contralateral breast, lungs, heart, esophagus, spine, and surrounding skin in the radiotherapy of breast cancer. Computed tomography (CT) data sets of 30 breast cancer patients were selected from the database for the study. The treatment plans which were executed with PW were re-planned with EDW without changing the beam parameters. Keeping the wedge angles same, the analytic anisotropic algorithm (AAA) with heterogeneity correction was used for dose calculation in all plans. The prescription was 50 Gy in 25 fractions. The dose- volume histogram (DVH) of the planning target volume (PTV) and critical structures of both PW and EDW plans were analyzed. The analysis showed that the maximum dose within the target volume is higher in EDW plan compared to PW plan. However the PTV conformity index (CI) remained the same in both plans. For all the critical structures, the EDW technique offered less dose compared to PW technique. The effect of volume of the contralateral breast on the dose to contralateral breast and the effect of volume of PTV breast for patients with carcinoma left breast on the dose to heart were studied and analyzed for the two wedges. No correlation between volumes and dose parameters was found for the two techniques. The number of monitor units to deliver a particular dose with EDW field is less than that of PW field due to change in wedge factor. As EDW produces less scattered dose to structures outside the treatment field, the risk of a second malignancy can be reduced with this technique.
Collapse
Affiliation(s)
| | - Raghuram K Nair
- Division of Radiation Physics, Regional Cancer Centre, Trivandrum, Kerala, India
| | - P Raghukumar
- Division of Radiation Physics, Regional Cancer Centre, Trivandrum, Kerala, India
| | - B Sarin
- Division of Radiation Physics, Regional Cancer Centre, Trivandrum, Kerala, India
| |
Collapse
|
10
|
Sayan M, Hard D, Wilson K, Nelson C, Gagne H, Rubin D, Heimann R. Long-term cosmesis following a novel schedule of accelerated partial breast radiation in selected early stage breast cancer: result of a prospective clinical trial. Radiat Oncol J 2017; 35:325-331. [PMID: 29207864 PMCID: PMC5769880 DOI: 10.3857/roj.2017.00171] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Revised: 07/06/2017] [Accepted: 07/10/2017] [Indexed: 11/03/2022] Open
Abstract
PURPOSE There is controversy regarding the cosmetic outcome after accelerated partial breast radiation (APBR). We report the cosmetic outcome from a single-arm prospective clinical trial of APBR delivered using intensity-modulated radiation therapy (IMRT) in elderly patients with stage I breast cancer (BC), using a novel fractionation schedule. MATERIALS AND METHODS Forty-two patients aged ≥65, with Stage I BC who underwent breast-conserving surgery were enrolled in a phase I/II study evaluating a 2-week course of APBR. Thirty eligible patients received 40 Gy in 4 Gy daily fractions. Cosmetic outcome was assessed subjectively by physician/patient and objectively by using a computer program (BCCT.core) before APBR, during, and after completion of the treatment. RESULTS The median age was 72 years, the median tumor size was 0.8 cm, and the median follow-up was 50.5 months. The 5-year locoregional control in this cohort was 97% and overall survival 87%. At the last follow-up, patients and physicians rated cosmesis as 'excellent' or 'good' in 100% and 91 %, respectively. The BCCT.core program scored the cosmesis as 'excellent' or 'good' in 87% of the patients at baseline and 81% at the last follow-up. The median V50 (20 Gy) of the whole breast volume (WBV) was 37.2%, with the median WBV V100 (40 Gy) of 10.9%. CONCLUSION An excellent rate of tumor control was observed in this prospective trial. By using multiple assessment techniques, we are showing acceptable cosmesis, supporting the use of IMRT planned APBR with daily schedule in elderly patients with early stage BC.
Collapse
Affiliation(s)
- Mutlay Sayan
- Department of Radiation Oncology, University of Vermont Medical Center, Burlington, VT, USA
| | - Daphne Hard
- Department of Radiation Oncology, University of Vermont Medical Center, Burlington, VT, USA
| | - Karen Wilson
- University of Vermont Cancer Center, Burlington, VT, USA
| | - Carl Nelson
- Department of Radiation Oncology, University of Vermont Medical Center, Burlington, VT, USA
| | - Havaleh Gagne
- Department of Radiation Oncology, University of Vermont Medical Center, Burlington, VT, USA
| | - Deborah Rubin
- Department of Radiation Oncology, University of Vermont Medical Center, Burlington, VT, USA
| | - Ruth Heimann
- Department of Radiation Oncology, University of Vermont Medical Center, Burlington, VT, USA
| |
Collapse
|
11
|
Aoulad N, Massabeau C, de Lafontan B, Vieillevigne L, Hangard G, Ciprian C, Chaltiel L, Moyal É, Izar F. Toxicité aiguë de la tomothérapie des cancers mammaires. Cancer Radiother 2017; 21:180-189. [DOI: 10.1016/j.canrad.2016.11.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2016] [Revised: 11/19/2016] [Accepted: 11/25/2016] [Indexed: 11/29/2022]
|
12
|
Sayan M, Wilson K, Nelson C, Gagne H, Rubin D, Heimann R. A novel schedule of accelerated partial breast radiation using intensity-modulated radiation therapy in elderly patients: survival and toxicity analysis of a prospective clinical trial. Radiat Oncol J 2017; 35:32-38. [PMID: 28183159 PMCID: PMC5398344 DOI: 10.3857/roj.2016.01963] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2016] [Revised: 10/19/2016] [Accepted: 11/11/2016] [Indexed: 12/30/2022] Open
Abstract
Purpose Several accelerated partial breast radiation (APBR) techniques have been investigated in patients with early-stage breast cancer (BC); however, the optimal treatment delivery techniques remain unclear. We evaluated the feasibility and toxicity of APBR delivered using intensity-modulated radiation therapy (IMRT) in elderly patients with stage I BC, using a novel fractionation schedule. Materials and Methods Forty-two patients aged ≥65 years, with stage I BC who underwent breast conserving surgery were enrolled in a phase I/II study evaluating APBR using IMRT. Forty eligible patients received 40 Gy in 4 Gy daily fractions. Patients were assessed for treatment related toxicities, and cosmesis, before APBR, during, and after completion of the treatment. Results The median age was 73 years, median tumor size 0.8 cm and the median follow-up was 54 months. The 5-year locoregional control was 97.5% and overall survival 90%. Erythema and skin pigmentation was the most common acute adverse event, reported by 27 patients (69%). Twenty-six patients (65%) reported mild pain, rated 1-4/10. This improved at last follow-up to only 2 (15%). Overall the patient and physician reported worst late toxicities were lower than the baseline and at last follow-up, patients and physicians rated cosmesis as excellent/good in 93% and 86 %, respectively. Conclusion In this prospective trial, we observed an excellent rate of tumor control with daily APBR. The acceptable toxicity profile and cosmetic results of this study support the use of IMRT planned APBR with daily schedule in elderly patients with early stage BC.
Collapse
Affiliation(s)
- Mutlay Sayan
- Department of Radiation Oncology, University of Vermont Medical Center, Burlington, VT, USA
| | - Karen Wilson
- University of Vermont Cancer Center, Burlington, VT, USA
| | - Carl Nelson
- Department of Radiation Oncology, University of Vermont Medical Center, Burlington, VT, USA
| | - Havaleh Gagne
- Department of Radiation Oncology, University of Vermont Medical Center, Burlington, VT, USA
| | - Deborah Rubin
- Department of Radiation Oncology, University of Vermont Medical Center, Burlington, VT, USA
| | - Ruth Heimann
- Department of Radiation Oncology, University of Vermont Medical Center, Burlington, VT, USA
| |
Collapse
|
13
|
Fiorentino A, Mazzola R, Ricchetti F, Giaj Levra N, Fersino S, Naccarato S, Sicignano G, Ruggieri R, Di Paola G, Massocco A, Gori S, Alongi F. Intensity modulated radiation therapy with simultaneous integrated boost in early breast cancer irradiation. Report of feasibility and preliminary toxicity. Cancer Radiother 2015. [PMID: 26206732 DOI: 10.1016/j.canrad.2015.02.013] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
PURPOSE To investigate the feasibility and tolerance in the use of adjuvant intensity modulated radiation therapy (IMRT) and simultaneous integrated boost in patients with a diagnosis of breast cancer after breast-conserving surgery. PATIENTS AND METHODS Between September 2011 to February 2013, 112 women with a diagnosis of early breast cancer (T1-2, N0-1, M0) were treated with IMRT and simultaneous integrated boost after breast-conserving surgery in our institution. A dose of 50Gy in 25 fractions was prescribed to the whole breast and an additional dose of radiation was prescribed on the tumour bed. A dose prescription of 60Gy in 25 fractions to the tumour bed was used in patients with negative margins after surgery, whereas if the margins were close (<1mm) or positive (without a new surgical resection) a dose of 64Gy was prescribed. All patients were followed with periodic clinical evaluation. Acute and late toxicity were scored using the EORTC/RTOG radiation morbidity score system. Both patient and physician recorded cosmetic outcome evaluation with a subjective judgment scale at the time of scheduled follow-up. RESULTS The median follow-up was 28 months (range 24-40 months). The acute skin grade toxicity during the treatment was grade 0 in 8 patients (7%), grade 1 in 80 (72%), grade 2 in 24 cases (21%). No grade 3 or higher acute skin toxicity was observed. At 12 months, skin toxicity was grade 0 in 78 patients (70%), grade 1 in 34 patients (30%). No toxicity grade 2 or higher was registered. At 24 months, skin toxicity was grade 0 in 79 patients (71%), grade 1 in 33 patients (29%). No case of grade 2 toxicity or higher was registered. The pretreatment variables correlated with skin grade 2 acute toxicity were adjuvant chemotherapy (P=0.01) and breast volume ≥700cm(3) (P=0.001). Patients with an acute skin toxicity grade 2 had a higher probability to develop late skin toxicity (P<0.0001). In the 98% of cases, patients were judged to have a good or excellent cosmetic outcome. The 2-year-overall survival and 2-year-local control were 100%. CONCLUSION These data support the feasibility and safety of IMRT with simultaneous integrated boost in patients with a diagnosis of early breast cancer following breast-conserving surgery with acceptable acute and late treatment-related toxicity. A longer follow-up is needed to define the efficacy on outcomes.
Collapse
MESH Headings
- Adult
- Aged
- Aged, 80 and over
- Breast Neoplasms/mortality
- Breast Neoplasms/pathology
- Breast Neoplasms/therapy
- Carcinoma, Ductal, Breast/mortality
- Carcinoma, Ductal, Breast/pathology
- Carcinoma, Ductal, Breast/therapy
- Carcinoma, Lobular/mortality
- Carcinoma, Lobular/pathology
- Carcinoma, Lobular/therapy
- Esthetics
- Feasibility Studies
- Female
- Follow-Up Studies
- Humans
- Mastectomy, Segmental
- Middle Aged
- Radiodermatitis/etiology
- Radiotherapy Dosage
- Radiotherapy, Adjuvant
- Radiotherapy, Intensity-Modulated
- Severity of Illness Index
Collapse
Affiliation(s)
- A Fiorentino
- Radiation oncology, Sacro Cuore-Don Calabria hospital, Negrar, Verona, Italy
| | - R Mazzola
- Radiation oncology, Sacro Cuore-Don Calabria hospital, Negrar, Verona, Italy; Radiation oncology school, university of Palermo, Palermo, Italy.
| | - F Ricchetti
- Radiation oncology, Sacro Cuore-Don Calabria hospital, Negrar, Verona, Italy
| | - N Giaj Levra
- Radiation oncology, Sacro Cuore-Don Calabria hospital, Negrar, Verona, Italy
| | - S Fersino
- Radiation oncology, Sacro Cuore-Don Calabria hospital, Negrar, Verona, Italy
| | - S Naccarato
- Radiation oncology, Sacro Cuore-Don Calabria hospital, Negrar, Verona, Italy
| | - G Sicignano
- Radiation oncology, Sacro Cuore-Don Calabria hospital, Negrar, Verona, Italy
| | - R Ruggieri
- Radiation oncology, Sacro Cuore-Don Calabria hospital, Negrar, Verona, Italy
| | - G Di Paola
- Statistic science faculty, university of Palermo, Palermo, Italy
| | - A Massocco
- Breast surgery, Sacro Cuore-Don Calabria hospital, Negrar, Verona, Italy
| | - S Gori
- Medical oncology, Sacro Cuore-Don Calabria hospital, Negrar, Verona, Italy
| | - F Alongi
- Radiation oncology, Sacro Cuore-Don Calabria hospital, Negrar, Verona, Italy
| |
Collapse
|
14
|
Amoush A, Murray E, Yu JS, Xia P. Single-isocenter hybrid IMRT plans versus two-isocenter conventional plans and impact of intrafraction motion for the treatment of breast cancer with supraclavicular lymph nodes involvement. J Appl Clin Med Phys 2015. [PMID: 26218994 PMCID: PMC5690023 DOI: 10.1120/jacmp.v16i4.5188] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
The purpose of this study was to compare the single‐isocenter, four‐field hybrid IMRT with the two‐isocenter techniques to treat the whole breast and supraclavicular fields and to investigate the intrafraction motions in both techniques in the superior direction. Fifteen breast cancer patients who underwent lumpectomy and adjuvant radiation to the whole breast and supraclavicular (SCV) fossa at our institution were selected for this study. Two planning techniques were compared for the treatment of the breast and SCV lymph nodes. The patients were divided into three subgroups according to the whole breast volume. For the two‐isocenter technique, conventional wedged or field‐within‐a‐field tangents (FIF) were used to match with the same anterior field for the SCV region. For the single‐isocenter technique, four‐field hybrid IMRT was used for the tangent fields matched with a half blocked anterior field for the SCV region. To simulate the intrafraction uncertainties in the longitudinal direction for both techniques, the treatment isocenters were shifted by 1 mm and 2 mm in the superior direction. The average breast clinical tumor volume (CTV) receiving 100% (V100%) of the prescription dose (50 Gy) was 99.3%±0.5% and 96.4%±1.2% for the for two‐isocenter and single‐isocenter plans (p<0.05), respectively. The breast CTV receiving 95% of the prescription dose (V95%) was close to 100% in both techniques. The average breast CTV receiving 105% (V105%) of the prescription dose was 32.4%±19.3% and 23.8%±13.3% (p=0.08). The percentage volume of the breast CTV receiving 110% of the dose was 0.4%±1.2% in the two‐isocentric technique vs. 0.1%±0.2% in the single‐isocentric technique. The average uniformity index was 0.91±0.02 vs. 0.91±0.01 in both techniques (p=0.04), but had no clinical impact. The percentage volume of the contralateral breast receiving a dose of 1 Gy was less than 2.3% in small breast patients and insignificant for medium and large breast sizes. The percentage of the total lung volume receiving g>20 Gy (V20Gy) and the heart receiving >30 Gy (V30Gy) were 13.6% vs. 14.3% (p=0.03) and 1.25% vs. 1.2% (p=0.62), respectively. Shifting the treatment isocenter by 1 mm and 2 mm superiorly showed that the average maximum dose to 1 cc of the breast volume was 55.5±1.8 Gy and 58.6±4.3 Gy in the two‐isocentric technique vs. 56.4±2.1 Gy and 59.1±5.1 Gy in the single‐isocentric technique (p=0.46, 0.87), respectively. The single‐isocenter technique using four‐field hybrid IMRT approach resulted in comparable plan quality as the two‐isocentric technique. The single‐isocenter technique is more sensitive to intrafraction motion in the superior direction compared to the two‐isocentric technique. The advantages of the single‐isocenter include elimination of isocentric errors due to couch and collimator rotations and reduction in treatment time. This study supports consideration of a single‐isocenter four‐field hybrid IMRT technique for patients undergoing breast and supraclavicular nodal irradiation. PACS number: 87.55.D, 87.55.de, 87.55.dk,
Collapse
|
15
|
Liu ZM, Ge XL, Chen JY, Wang PP, Zhang C, Yang X, Zhu HC, Liu J, Qin Q, Xu LP, Lu J, Zhan LL, Cheng HY, Sun XC. Adjuvant Radiotherapy after Breast Conserving Treatment for Breast Cancer: A Dosimetric Comparison between Volumetric Modulated Arc Therapy and Intensity Modulated Radiotherapy. Asian Pac J Cancer Prev 2015; 16:3257-65. [PMID: 25921129 DOI: 10.7314/apjcp.2015.16.8.3257] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Radiotherapy is an important treatment of choice for breast cancer patients after breast- conserving surgery, and we compare the feasibility of using dual arc volumetric modulated arc therapy (VMAT2), single arc volumetric modulated arc therapy (VMAT1) and Multi-beam Intensity Modulated Radiotherapy (M-IMRT) on patients after breast-conserving surgery. MATERIALS AND METHODS Thirty patients with breast cancer (half right-sided and half left-sided) treated by conservative lumpectomy and requiring whole breast radiotherapy with tumor bed boost were planned with three different radiotherapy techniques: 1) VMAT1; 2) VMAT2; 3) M-IMRT. The distributions for the planning target volume (PTV) and organs at risk (OARs) were compared. Dosimetries for all the techniques were compared. RESULTS All three techniques satisfied the dose constraint well. VMAT2 showed no obvious difference in the homogeneity index (HI) and conformity index (CI) of the PTV with respect to M-IMRT and VMAT1. VMAT2 clearly improved the treatment efficiency and can also decrease the mean dose and V5Gy of the contralateral lung. The mean dose and maximum dose of the spinal cord and contralateral breast were lower for VMAT2 than the other two techniques. The very low dose distribution (V1Gy) of the contralateral breast also showed great reduction in VMAT2 compared with the other two techniques. For the ipsilateral lung of right-sided breast cancer, the mean dose was decreased significantly in VMAT2 compared with VMAT1 and M-IMRT. The V20Gy and V30Gy of the ipsilateral lung of the left- sided breast cancer for VMAT2 showed obvious reduction compared with the other two techniques. The heart statistics of VMAT2 also decreased considerably compared to VMAT1 and M-IMRT. CONCLUSIONS Compared to the other two techniques, the dual arc volumetric modulated arc therapy technique reduced radiation dose exposure to the organs at risk and maintained a reasonable target dose distribution.
Collapse
Affiliation(s)
- Zhe-Ming Liu
- Department of Radiation Oncology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China E-mail : ;
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Wojcieszynski AP, Olson AK, Rong Y, Kimple RJ, Yadav P. Acute Toxicity From Breast Cancer Radiation Using Helical Tomotherapy With a Simultaneous Integrated Boost. Technol Cancer Res Treat 2015; 15:257-65. [PMID: 25780060 DOI: 10.1177/1533034615574387] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2014] [Accepted: 01/29/2015] [Indexed: 11/16/2022] Open
Abstract
PURPOSE To evaluate 2 simultaneous integrated boost treatment planning techniques using helical tomotherapy for breast conserving therapy with regard to acute skin toxicity and dosimetry. METHODS Thirty-two patients were studied. The original approach was for 16 patients and incorporated a directional block of the ipsilateral lung and breast. An additional 16 patients were planned for using a modified approach that incorporates a full block of the ipsilateral lung exclusive of 4 cm around the breast. Dose-volume histograms of targets and critical structures were evaluated. Skin toxicity monitoring was performed throughout treatment and follow-up using the Common Terminology Criteria for Adverse Events. RESULTS Treatment was well tolerated with patients receiving a median dose of 59.36 Gy. Of the 16 patients in both groups, 8 had grade 2 erythema immediately after radiation. On 3-week follow-up, 10 and 7 patients in the original and modified groups showed grade 1 erythema. On 3- and 6-month follow-up, both groups had minimal erythema, with all patients having either grade 0 or 1 symptoms. No grade 2 or 3 toxicities were reported. Mean treatment time was 7.5 and 10.4 minutes using the original and modified methods. Adequate dose coverage was achieved using both methods (V95 = 99.5% and 98%). Mean dose to the heart was 10.5 and 1.8 Gy, respectively (P < .01). For right-sided tumors, the original and modified plans yielded a mean of 8.8 and 1.1 Gy (P < .01) versus 11.7 and 2.4 Gy for left-sided tumors (P < .01). The mean dose to the ipsilateral lung was also significantly lower in the modified plans (11.8 vs. 5.0 Gy, P < .01). CONCLUSIONS Tomotherapy is capable of delivering homogeneous treatment plans to the whole breast and lumpectomy cavity using simultaneous integrated boost treatment. Using the treatment methods described herein, extremely low doses to critical structures can be achieved without compromising acute skin toxicity.
Collapse
Affiliation(s)
- Andrzej P Wojcieszynski
- Department of Human Oncology, University of Wisconsin Hospital and Clinics, Madison, WI, USA
| | - Anna K Olson
- Department of Human Oncology, University of Wisconsin Hospital and Clinics, Madison, WI, USA Department of Radiation Oncology, Riverview Hospital, Wisconsin Rapids, WI, USA
| | - Yi Rong
- Department of Radiation Oncology, University of California Davis Comprehensive Cancer Center, University of California, Sacramento, CA, USA
| | - Randall J Kimple
- Department of Human Oncology, University of Wisconsin Hospital and Clinics, Madison, WI, USA Department of Radiation Oncology, University of Wisconsin Carbone Cancer Center, University of Wisconsin, Madison, WI, USA
| | - Poonam Yadav
- Department of Human Oncology, University of Wisconsin Hospital and Clinics, Madison, WI, USA Department of Radiation Oncology, Riverview Hospital, Wisconsin Rapids, WI, USA
| |
Collapse
|
17
|
Lee HC, Kim SH, Suh YJ, Chung MJ, Kang DG, Choi HJ, Lee JH. A prospective cohort study on postoperative radiotherapy with TomoDirect using simultaneous integrated boost technique in early breast cancer. Radiat Oncol 2014; 9:244. [PMID: 25410791 PMCID: PMC4244044 DOI: 10.1186/s13014-014-0244-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2014] [Accepted: 10/30/2014] [Indexed: 12/25/2022] Open
Abstract
PURPOSE To evaluate the technical feasibility and toxicity of TomoDirect in breast cancer patients who received radiotherapy after breast-conserving surgery. METHODS 155 consecutive patients with breast carcinoma in situ or T1-2 breast cancer with negative lymph node received breast irradiation with TomoDirect using simultaneous integrated boost technique in the prospective cohort study. A radiation dose of 50.4 Gy and 57.4 Gy in 28 fractions was prescribed to the ipsilateral breast and tumor bed, respectively. Dosimetric parameters of target and organ at risk and acute complication were assessed prospectively. RESULTS The mean dose for the tumor bed is 58.90 Gy. The mean values of V54.53Gy (95% of the prescribed dose), V63.14Gy (110% of the prescribed dose), and V66.01Gy (115% of the prescribed dose) were 99.97%, 1.26%, and 0%, respectively. The mean value of radiation conformality index was 1.01. The mean value of radical dose homogeneity index was 0.89. The average dose irradiated to the ipsilateral lung, heart, and contralateral breast was 4.72 Gy, 1.09 Gy, and 0.19 Gy, respectively. The most common toxicity was dermatitis. During breast irradiation, grade 2 and 3 dermatitis occurred in 41 (26.5%) and 6 (3.9%) of the 155 patients, respectively. Two patients had arm lymphedema during breast irradiation. Two patients had grade 2 pneumonitis 1 month after breast irradiation. CONCLUSIONS Radiotherapy using TomoDirect in early breast cancer patients showed acceptable toxicities and optimal results in terms of target coverage and organ at risk sparing.
Collapse
Affiliation(s)
- Hyo Chun Lee
- Department of Radiation Oncology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea, 442-723, 93-6, Ji-dong, Paldal-gu, Suwon, Kyeonggi-do, Republic of Korea.
| | - Sung Hwan Kim
- Department of Radiation Oncology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea, 442-723, 93-6, Ji-dong, Paldal-gu, Suwon, Kyeonggi-do, Republic of Korea.
| | - Young Jin Suh
- Department of Surgery, St. Vincent's Hospital, The Catholic University of Korea, Seoul, Republic of Korea.
| | - Mi Joo Chung
- Department of Radiation Oncology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea, 442-723, 93-6, Ji-dong, Paldal-gu, Suwon, Kyeonggi-do, Republic of Korea.
| | - Dae Gyu Kang
- Department of Radiation Oncology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea, 442-723, 93-6, Ji-dong, Paldal-gu, Suwon, Kyeonggi-do, Republic of Korea.
| | - Hyun Joo Choi
- Department of Hospital Pathology, St. Vincent's Hospital, The Catholic University of Korea, Seoul, Republic of Korea.
| | - Jong Hoon Lee
- Department of Radiation Oncology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea, 442-723, 93-6, Ji-dong, Paldal-gu, Suwon, Kyeonggi-do, Republic of Korea.
| |
Collapse
|
18
|
He Z, Wu S, Zhou J, Li F, Sun J, Lin Q, Lin H, Guan X. Accelerated partial breast irradiation with intensity-modulated radiotherapy is feasible for chinese breast cancer patients. J Breast Cancer 2014; 17:256-64. [PMID: 25320624 PMCID: PMC4197356 DOI: 10.4048/jbc.2014.17.3.256] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2014] [Accepted: 07/26/2014] [Indexed: 01/29/2023] Open
Abstract
PURPOSE Several accelerated partial breast irradiation (APBI) techniques are being investigated in patients with early-stage breast cancer. The present study evaluated the feasibility, early toxicity, initial efficacy, and cosmetic outcomes of accelerated partial breast intensity-modulated radiotherapy (IMRT) for Chinese female patients with early-stage breast cancer after breast-conserving surgery. METHODS A total of 38 patients met the inclusion criteria and an accelerated partial breast intensity-modulated radiotherapy (APBI-IMRT) plan was designed for each patient. The prescription dose was 34 Gy in 10 fractions, 3.4 Gy per fraction, twice a day, in intervals of more than 6 hours. RESULTS Of the 38 patients, six patients did not meet the planning criteria. The remaining 32 patients received APBI-IMRT with a mean target volume conformity index of 0.67 and a dose homogeneity index of 1.06. The median follow-up time was 53 months and no local recurrence or distant metastasis was detected. The most common acute toxicities observed within 3 months after radiotherapy were erythema, breast edema, pigmentation, and pain in the irradiated location, among which 43.8%, 12.5%, 31.3%, and 28.1% were grade 1 toxicities, respectively. The most common late toxicities occurring after 3 months until the end of the follow-up period were breast edema, pigmentation, pain in the irradiated location, and subcutaneous fibrosis, among which 6.2%, 28.1%, 21.9%, and 37.5% were grade 1 toxicities, respectively. Thirty-one patients (96.8%) had fine or excellent cosmetic outcomes, and only one patient had a poor cosmetic outcome. CONCLUSION It is feasible for Chinese females to receive APBI-IMRT after breast conserving surgery. The radiotherapeutic toxicity is acceptable, and both the initial efficacy and cosmetic outcomes are good.
Collapse
Affiliation(s)
- Zhenyu He
- Department of Radiation Oncology, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangzhou, China
| | - Sangang Wu
- Department of Radiation Oncology, Xiamen Cancer Center, The First Affiliated Hospital of Xiamen University, Xiamen, China
| | - Juan Zhou
- Department of Obstetrics and Gynecology, Xiamen Cancer Center, The First Affiliated Hospital of Xiamen University, Xiamen, China
| | - Fengyan Li
- Department of Radiation Oncology, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangzhou, China
| | - Jiayan Sun
- Department of Radiation Oncology, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangzhou, China
| | - Qin Lin
- Department of Radiation Oncology, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangzhou, China
| | - Huanxin Lin
- Department of Radiation Oncology, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangzhou, China
| | - Xunxing Guan
- Department of Radiation Oncology, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Guangzhou, China
| |
Collapse
|
19
|
Falk AT, Fenoglietto P, Azria D, Bourgier C. [New external radiotherapy technologies for breast cancer]. Cancer Radiother 2014; 18:480-5. [PMID: 25182528 DOI: 10.1016/j.canrad.2014.06.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Revised: 06/24/2014] [Accepted: 06/26/2014] [Indexed: 10/24/2022]
Abstract
The purpose of new radiotherapy techniques is to better deliver dose conformation in the tumour volume while diminishing organs at risk exposition. Their development is soaring in the breast cancer field in the adjuvant setting with intensity-modulated radiation therapy but also in cerebral and extracerebral oligometastastic presentation. Their usage is still being debated for breast cancer care. The objective of this narrative review is to list and discuss clinical data at our disposal for these news technologies.
Collapse
Affiliation(s)
- A T Falk
- Département de radiothérapie, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2, France; Université de Nice Sophia-Antipolis, BP 2135, 06103 Nice cedex 2, France
| | - P Fenoglietto
- Département de radiothérapie oncologique, centre régional de lutte contre le cancer, 208, rue des Apothicaires, parc Euromédecine, 34298 Montpellier cedex 05, France
| | - D Azria
- Département de radiothérapie oncologique, centre régional de lutte contre le cancer, 208, rue des Apothicaires, parc Euromédecine, 34298 Montpellier cedex 05, France; Inserm U896, institut de recherche en cancérologie de Montpellier, 208, rue des Apothicaires, parc Euromédecine, 34298 Montpellier cedex 05, France; Université de Montpellier 1, CS 19044, 34967 Montpellier cedex 2, France
| | - C Bourgier
- Département de radiothérapie oncologique, centre régional de lutte contre le cancer, 208, rue des Apothicaires, parc Euromédecine, 34298 Montpellier cedex 05, France; Inserm U896, institut de recherche en cancérologie de Montpellier, 208, rue des Apothicaires, parc Euromédecine, 34298 Montpellier cedex 05, France; Université de Montpellier 1, CS 19044, 34967 Montpellier cedex 2, France.
| |
Collapse
|
20
|
Quinn A, Holloway L, Hardcastle N, Tomé WA, Rosenfeld A, Metcalfe P. Normal tissue dose and second cancer risk due to megavoltage fan-beam CT, static tomotherapy and helical tomotherapy in breast radiotherapy. Radiother Oncol 2013; 108:266-8. [DOI: 10.1016/j.radonc.2013.05.019] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2012] [Revised: 05/13/2013] [Accepted: 05/21/2013] [Indexed: 11/25/2022]
|
21
|
A comparative dosimetric study for treating left-sided breast cancer for small breast size using five different radiotherapy techniques: conventional tangential field, filed-in-filed, tangential-IMRT, multi-beam IMRT and VMAT. Radiat Oncol 2013; 8:89. [PMID: 23587298 PMCID: PMC3648459 DOI: 10.1186/1748-717x-8-89] [Citation(s) in RCA: 91] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2012] [Accepted: 04/10/2013] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND AND PURPOSES To compare the dosimetry for the left-sided breast cancer treatment using five different radiotherapy techniques. MATERIALS AND METHODS Twenty patients with left sided breast cancer were treated with conservative surgery followed by radiotherapy. They were planned using five different radiotherapy techniques, including: 1) conventional tangential wedge-based fields (TW); 2) field-in-field (FIF) technique; 3) tangential inverse planning intensity-modulated radiation therapy (T-IMRT); 4) multi-field IMRT (M-IMRT); and 5) volumetric modulated arc therapy (VMAT). The CTV, PTV and OARs including the heart, the regions of coronary artery (CA), the contralateral breast, the left and right lung were delineated. The PTV dose was prescribed 50Gy and V47.5≥95%. Same dose constraint was used for all five plans. The planned volumetric dose of PTV and PRV-OARs were compared and analyzed. RESULTS Except VMAT (Average V47.5 was 94.72%±1.2%), all the other four plans were able to meet the V95% (V47.5) requirement. T-IMRT plan improved the PTV dose homogeneity index (HI) by 0.02 and 0.03 when compared to TW plan and VMAT plan, and decreased the V5, V10 and V20 of all PRV-OARs. However, the high dose volume (≥ 30Gy) of the PRV-OARs in T-IMRT plan had no statistically significant difference compared with the other two inverse plans. In all five plans, the dose volume of coronary artery area showed a strong correlation to the dose volume of the heart (the correlation coefficients were 0.993, 0.996, 1.000, 0.995 and 0.986 respectively). CONCLUSION Compared to other techniques, the T-IMRT technology reduced radiation dose exposure to normal tissues and maintained reasonable target homogeneity, VMAT is not recommended for left-sided breast cancer treatment. In five techniques, the dose-volume histogram (DVH) of the heart can be used to predict the dose-volume histogram (DVH) of the coronary artery.
Collapse
|
22
|
Sun LM, Huang EY, Liang JA, Meng FY, Chang GH, Tsao MJ. Evaluation the consistency of location of moist desquamation and skin high dose area for breast cancer patients receiving adjuvant radiotherapy after breast conservative surgery. Radiat Oncol 2013; 8:50. [PMID: 23497574 PMCID: PMC3599924 DOI: 10.1186/1748-717x-8-50] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2012] [Accepted: 03/01/2013] [Indexed: 12/21/2022] Open
Abstract
Background To evaluate whether the location of moist desquamation matches high dose area for breast cancer patients receiving adjuvant radiotherapy (RT) after breast conservative surgery. Methods One hundred and nine breast cancer patients were enrolled to this study. Their highest skin dose area (the hot spot) was estimated from the treatment planning. We divided the irradiated field into breast; sternal/parasternal; axillary; and inframammary fold areas. The location for moist desquamation was recorded to see if it matches the hot spot. We also analyzed other possible risk factors which may be related to the moist desquamation. Results Forty-eight patients with 65 locations developed moist desquamation during the RT course. Patients with larger breast sizes and easy to sweat are two independent risk factors for moist desquamation. The distribution of moist desquamation occurred most in the axillary area. All nine patients with the hot spots located at the axillary area developed moist desquamation at the axillary area, and six out of seven patients with the hot spots located at the inframammary fold developed moist desquamation there. The majority of patients with moist desquamation over the breast or sternal/parasternal areas had the hot spots located at these areas. Conclusions For a patient with moist desquamation, if a hot spot is located at the axillary or inframammary fold areas, it is very likely to have moist desquamation occur there. On the other hand, if moist desquamation occurs over the breast or sternal/parasternal areas, we can highly expect these two areas are also the hot spot locations.
Collapse
Affiliation(s)
- Li-Min Sun
- Department of Radiation Oncology, Zuoying Branch of Kaohsiung Armed Forces General Hospital, 553 Junxiao Rd, Zuoying District, Kaohsiung, Taiwan.
| | | | | | | | | | | |
Collapse
|
23
|
Al-Rahbi ZS, Ravichandran R, Binukumar JP, Davis CA, Satyapal N, Al-Mandhari Z. A Dosimetric Comparison of Radiotherapy Techniques in the Treatment of Carcinoma of Breast. ACTA ACUST UNITED AC 2013. [DOI: 10.4236/jct.2013.411a002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
24
|
Shiau AC, Chiu MC, Chen TH, Chiou JF, Shueng PW, Chen SW, Chen WL, Kuan WP. Surface and superficial dose dosimetric verification for postmastectomy radiotherapy. Med Dosim 2012; 37:417-24. [DOI: 10.1016/j.meddos.2012.03.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2011] [Revised: 02/26/2012] [Accepted: 03/15/2012] [Indexed: 10/28/2022]
|
25
|
Templeton A, Chu J, Sun M, Yao R, Sun J, Coon A, Bernard D, Shott S, Griem K. Thermal Effusivity Changes as a Precursor to Moist Desquamation. Radiat Res 2012; 178:295-303. [DOI: 10.1667/rr2745.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
26
|
Capelle L, Warkentin H, MacKenzie M, Joseph K, Gabos Z, Pervez N, Tankel K, Chafe S, Amanie J, Ghosh S, Parliament M, Abdulkarim B. Skin-sparing Helical Tomotherapy vs 3D-conformal Radiotherapy for Adjuvant Breast Radiotherapy: In Vivo Skin Dosimetry Study. Int J Radiat Oncol Biol Phys 2012; 83:e583-90. [DOI: 10.1016/j.ijrobp.2012.01.086] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2011] [Revised: 01/06/2012] [Accepted: 01/30/2012] [Indexed: 10/28/2022]
|
27
|
Kim JH, Hill R, Kuncic Z. An evaluation of calculation parameters in the EGSnrc/BEAMnrc Monte Carlo codes and their effect on surface dose calculation. Phys Med Biol 2012; 57:N267-78. [DOI: 10.1088/0031-9155/57/14/n267] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
28
|
Rong Y, Yadav P, Welsh JS, Fahner T, Paliwal B. Postmastectomy radiotherapy with integrated scar boost using helical tomotherapy. Med Dosim 2012; 37:233-9. [PMID: 22365416 DOI: 10.1016/j.meddos.2011.09.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2011] [Revised: 06/14/2011] [Accepted: 09/06/2011] [Indexed: 11/29/2022]
Abstract
The purpose of this study was to evaluate helical tomotherapy dosimetry in postmastectomy patients undergoing treatment for chest wall and positive nodal regions with simultaneous integrated boost (SIB) in the scar region using strip bolus. Six postmastectomy patients were scanned with a 5-mm-thick strip bolus covering the scar planning target volume (PTV) plus 2-cm margin. For all 6 cases, the chest wall received a total cumulative dose of 49.3-50.4 Gy with daily fraction size of 1.7-2.0 Gy. Total dose to the scar PTV was prescribed to 58.0-60.2 Gy at 2.0-2.5 Gy per fraction. The supraclavicular PTV and mammary nodal PTV received 1.7-1.9 dose per fraction. Two plans (with and without bolus) were generated for all 6 cases. To generate no-bolus plans, strip bolus was contoured and overrode to air density before planning. The setup reproducibility and delivered dose accuracy were evaluated for all 6 cases. Dose-volume histograms were used to evaluate dose-volume coverage of targets and critical structures. We observed reduced air cavities with the strip bolus setup compared with what we normally see with the full bolus. The thermoluminescence dosimeters (TLD) in vivo dosimetry confirmed accurate dose delivery beneath the bolus. The verification plans performed on the first day megavoltage computed tomography (MVCT) image verified that the daily setup and overall dose delivery was within 2% accuracy compared with the planned dose. The hotspot of the scar PTV in no-bolus plans was 111.4% of the prescribed dose averaged over 6 cases compared with 106.6% with strip bolus. With a strip bolus only covering the postmastectomy scar region, we observed increased dose uniformity to the scar PTV, higher setup reproducibility, and accurate dose delivered beneath the bolus. This study demonstrates the feasibility of using a strip bolus over the scar using tomotherapy for SIB dosimetry in postmastectomy treatments.
Collapse
Affiliation(s)
- Yi Rong
- Department of Human Oncology, University of Wisconsin, Madison, Madison, WI, USA.
| | | | | | | | | |
Collapse
|
29
|
Tolia M, Platoni K, Foteineas A, Kalogeridi MA, Zygogianni A, Tsoukalas N, Caimi M, Margari N, Dilvoi M, Pantelakos P, Kouvaris J, Kouloulias V. Assessment of contralateral mammary gland dose in the treatment of breast cancer using accelerated hypofractionated radiotherapy. World J Radiol 2011; 3:233-40. [PMID: 22013502 PMCID: PMC3194044 DOI: 10.4329/wjr.v3.i9.233] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2011] [Revised: 07/18/2011] [Accepted: 07/25/2011] [Indexed: 02/06/2023] Open
Abstract
AIM: To measure the dose distribution, related to the treatment planning calculations, in the contralateral mammary gland of breast cancer patients treated with accelerated hypofractionated 3-dimensional conformal radiotherapy.
METHODS: Thirty-four prospectively selected female patients with right breast cancer (pN0, negative surgical margins) were treated with breast-conserving surgery. A total dose of 42.5 Gy (2.66 Gy/fraction) was prescribed; it was requested that planning target volumes be covered by the 95% isodose line. The contralateral mammary gland was defined on CT simulation. The dose received was evaluated by dose volume histograms.
RESULTS: The measured contralateral breast doses were: (1) Dose maximum: 290-448 cGy [Equivalent (Eq) 337-522 cGy]; (2) Mean dose: 45-70 cGy (Eq 524-815 cGy); and (3) Median dose: 29-47 cGy (337-547 cGy) for total primary breast dose of 42.5 Gy in 16 equal fractions. The spearman rho correlation showed statistical significance between the contralateral breast volume and maximum dose (P = 0.0292), as well as mean dose (P = 0.0025) and median dose (P = 0.046) to the breast.
CONCLUSION: Minimizing the dose to the contralateral breast has to be one of the priorities of the radiation oncologist when using short schedules because of the radiosensitivity of this organ at risk. Further study is necessary to assess the long-term clinical impact of this schedule.
Collapse
|
30
|
Rong Y, Welsh JS. Dosimetric and clinical review of helical tomotherapy. Expert Rev Anticancer Ther 2011; 11:309-20. [PMID: 21342048 DOI: 10.1586/era.10.175] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
As a modality for delivering rotational therapy, helical tomotherapy offers dosimetric advantages by combining a continuously rotating gantry with a binary multileaf collimator. Helical tomotherapy, embodied in the TomoTherapy(®) Hi-Art II(®) system, delivers intensity-modulated fan beams in a helical pattern using binary multileaf collimator leaves while the couch is translated through the gantry. Helical tomotherapy offers the possibility of treating a variety of cases--from simple to complex--with improved target conformality and sensitive structure sparing compared with 3D or conventional static field IMRT plans, thereby allowing biologically effective dose escalation. For precise irradiation and possible treatment adaptation, the fully integrated on-board image-guidance system provides online volumetric images of patient anatomy using 3.5-MV x-ray beams and the xenon computed tomography detector. Several review articles were published before the year 2007 but emphasized the technical aspects of helical tomotherapy. In this article, we review very recent papers and focus on the dosimetric and clinical aspects of helical tomotherapy.
Collapse
Affiliation(s)
- Yi Rong
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin-Madison, 600 Highland Avenue, Madison, WI, USA.
| | | |
Collapse
|
31
|
Zhou GX, Xu SP, Dai XK, Ju ZJ, Gong HS, Xie CB, Yin LM, Yang J. Clinical Dosimetric Study of Three Radiotherapy Techniques for Postoperative Breast Cancer: Helical Tomotherapy, IMRT, and 3D-CRT. Technol Cancer Res Treat 2011; 10:15-23. [PMID: 21214284 DOI: 10.7785/tcrt.2012.500174] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
This paper is to investigate the dosimetric characteristics of Helical Tomotherapy (HT), step-and-shoot intensity-modulated radiation therapy (SaS-IMRT) and three-dimensional conformal radiation therapy (3D-CRT) for the postoperative breast cancer as well as their dosimetric comparison of the normal tissues. CT images of 10 postoperative patients with early stage breast cancer were transferred into HT, SaS-IMRT and 3D-CRT planning systems respectively after the target region and normal tissues were outlined by the same physician to assure the contour consistency. Each prescribed dose for three different modalities of plans was given to a total of 50 Gy in 25 fractions. Doses and irradiated volumes in heart, lungs, as well as conformity index (CI) and homogeneity index (HI) were evaluated for detailed comparison. All three plans showed appropriate coverage for the prescribed target dose in the dosimetric comparison. The CI in HT and SaS-IMRT as well as 3D-CRT was 0.68 ± 0.12, 0.58 ± 0.08 and 0.40 ± 0.08, respectively. The HI were 1.10 ± 0.03, 1.14 ± 0.02 and 1.17 ± 0.04, which appeared intergroup significant differences (p < 0.05). V5, V10, as well as V20 of the heart were smallest in 3D-CRT than HT and SaS-IMRT. V5 of the ipsilateral lung was the smallest in 3D-CRT than HT and SaS-IMRT (p < 0.05); However, V20 and V30 were smaller in HT and SaS-IMRT than 3D-CRT (p < 0.05). V5 of the contralateral lung was the smallest in 3D-CRT than other groups, with V10~V30 were basically similar in numeric values with not obvious discrepancy. Comparing with SaS-IMRT and 3D-CRT, HT technique in treating breast cancer had the best conformity and homogeneity index as well as steepest dose gradient due to its highly modulated beamlets with rotational technique. The heart volume irradiated was the smallest in conventional 3D-CRT, with SaS-IMRT was the largest among the three techniques, as expected. The volume of the contralateral lung irradiated was the smallest in 3D-CRT than other groups. V5 of the ipsilateral lung was the smallest in 3D-CRT than other two groups. V10~V30 in HT and SaS-IMRT were similar and better than 3D-CRT dosimetrically. We conclude that HT technique had advantages over SaS-IMRT and 3D-CRT based on the dosimetric comparison in this study, especially in the high dose region of ipsilateral lung, target homogeneity and dose uniformity.
Collapse
Affiliation(s)
- G-X. Zhou
- Department of Radiation oncology Chinese PLA General Hospital, Beijing 100853, China
| | - S-P. Xu
- Department of Radiation oncology Chinese PLA General Hospital, Beijing 100853, China
| | - X-K. Dai
- Department of Radiation oncology Chinese PLA General Hospital, Beijing 100853, China
| | - Z-J. Ju
- Department of Radiation oncology Chinese PLA General Hospital, Beijing 100853, China
| | - H-S. Gong
- Department of Radiation oncology Chinese PLA General Hospital, Beijing 100853, China
| | - C-B. Xie
- Department of Radiation oncology Chinese PLA General Hospital, Beijing 100853, China
| | - L-M. Yin
- Department of Radiation oncology Chinese PLA General Hospital, Beijing 100853, China
| | - J. Yang
- Department of Radiation Oncology Monmouth Medical Center 300 2nd Avenue Long Branch, NJ 07740
| |
Collapse
|
32
|
Wang X, Amos RA, Zhang X, Taddei PJ, Woodward WA, Hoffman KE, Yu TK, Tereffe W, Oh J, Perkins GH, Salehpour M, Zhang SX, Sun TL, Gillin M, Buchholz TA, Strom EA. External-beam accelerated partial breast irradiation using multiple proton beam configurations. Int J Radiat Oncol Biol Phys 2010; 80:1464-72. [PMID: 20708848 DOI: 10.1016/j.ijrobp.2010.04.052] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2010] [Revised: 04/02/2010] [Accepted: 04/06/2010] [Indexed: 10/19/2022]
Abstract
PURPOSE To explore multiple proton beam configurations for optimizing dosimetry and minimizing uncertainties for accelerated partial breast irradiation (APBI) and to compare the dosimetry of proton with that of photon radiotherapy for treatment of the same clinical volumes. METHODS AND MATERIALS Proton treatment plans were created for 11 sequential patients treated with three-dimensional radiotherapy (3DCRT) photon APBI using passive scattering proton beams (PSPB) and were compared with clinically treated 3DCRT photon plans. Monte Carlo calculations were used to verify the accuracy of the proton dose calculation from the treatment planning system. The impact of range, motion, and setup uncertainty was evaluated with tangential vs. en face beams. RESULTS Compared with 3DCRT photons, the absolute reduction of the mean of V100 (the volume receiving 100% of prescription dose), V90, V75, V50, and V20 for normal breast using protons are 3.4%, 8.6%, 11.8%, 17.9%, and 23.6%, respectively. For breast skin, with the similar V90 as 3DCRT photons, the proton plan significantly reduced V75, V50, V30, and V10. The proton plan also significantly reduced the dose to the lung and heart. Dose distributions from Monte Carlo simulations demonstrated minimal deviation from the treatment planning system. The tangential beam configuration showed significantly less dose fluctuation in the chest wall region but was more vulnerable to respiratory motion than that for the en face beams. Worst-case analysis demonstrated the robustness of designed proton beams with range and patient setup uncertainties. CONCLUSIONS APBI using multiple proton beams spares significantly more normal tissue, including nontarget breast and breast skin, than 3DCRT using photons. It is robust, considering the range and patient setup uncertainties.
Collapse
Affiliation(s)
- Xiaochun Wang
- Department of Radiation Physics, The University of Texas, M D Anderson Cancer Center, Houston, TX 77030, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Sas-Korczyńska B, Sladowska A, Rozwadowska-Bogusz B, Dyczek S, Lesiak J, Kokoszka A, Korzeniowski S. Comparison between intensity modulated radiotherapy (IMRT) and 3D tangential beams technique used in patients with early-stage breast cancer who received breast-conserving therapy. Rep Pract Oncol Radiother 2010; 15:79-86. [PMID: 24376929 DOI: 10.1016/j.rpor.2010.06.002] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2010] [Revised: 06/22/2010] [Accepted: 06/24/2010] [Indexed: 10/19/2022] Open
Abstract
BACKGROUND The most often found complications in patients with breast cancer who received radiotherapy are cardiac and pulmonary function disorders and development of second malignancies. AIM To compare the intensity modulated radiotherapy with the 3D tangential beams technique in respect of dose distribution in target volume and critical organs they generate in patients with early-stage breast cancer who received breast-conserving therapy. MATERIALS AND METHODS A dosimetric analysis was performed to assess the three radiotherapy techniques used in each of 10 consecutive patients with early-stage breast cancer treated with breast-conserving therapy. Radiotherapy was planned with the use of all the three techniques: 3D tangential beams with electron boost, IMRT with electron boost, and intensity modulated radiotherapy with simultaneous integrated boost. RESULTS The use of the IMRT techniques enables more homogenous dose distribution in target volume. The range of mean and median dose to the heart and lung was lower with the IMRT techniques in comparison to the 3D tangential beams technique. The range of mean dose to the heart amounted to 0.3-3.5 Gy for the IMRT techniques and 0.4-4.3 for the tangential beams technique. The median dose to the lung on the irradiated side amounted to 4.9-5 Gy for the IMRT techniques and 5.6 Gy for the 3D tangential beams technique. CONCLUSION The application of the IMRT techniques in radiotherapy patients with early-stage breast cancer allows to obtain more homogenous dose distribution in target volume, while permitting to reduce the dose to critical organs.
Collapse
Affiliation(s)
- Beata Sas-Korczyńska
- Breast and Thoracic Cancer Unit, Centre of Oncology, Maria Skłodowska-Curie Memorial Institute, Cracow Branch, Garncarska 11, 31-115 Kraków, Poland
| | - Anna Sladowska
- Medical Physics, Centre of Oncology, Maria Skłodowska-Curie Memorial Institute, Cracow Branch, Garncarska 11, 31-115 Kraków, Poland
| | - Bożena Rozwadowska-Bogusz
- Medical Physics, Centre of Oncology, Maria Skłodowska-Curie Memorial Institute, Cracow Branch, Garncarska 11, 31-115 Kraków, Poland
| | - Sonia Dyczek
- Diagnostic Radiology, Centre of Oncology, Maria Skłodowska-Curie Memorial Institute, Cracow Branch, Garncarska 11, 31-115 Kraków, Poland
| | - Jan Lesiak
- Medical Physics, Centre of Oncology, Maria Skłodowska-Curie Memorial Institute, Cracow Branch, Garncarska 11, 31-115 Kraków, Poland
| | - Anna Kokoszka
- Breast and Thoracic Cancer Unit, Centre of Oncology, Maria Skłodowska-Curie Memorial Institute, Cracow Branch, Garncarska 11, 31-115 Kraków, Poland
| | - Stanisław Korzeniowski
- Breast and Thoracic Cancer Unit, Centre of Oncology, Maria Skłodowska-Curie Memorial Institute, Cracow Branch, Garncarska 11, 31-115 Kraków, Poland
| |
Collapse
|
34
|
Descovich M, Fowble B, Bevan A, Schechter N, Park C, Xia P. Comparison Between Hybrid Direct Aperture Optimized Intensity-Modulated Radiotherapy and Forward Planning Intensity-Modulated Radiotherapy for Whole Breast Irradiation. Int J Radiat Oncol Biol Phys 2010; 76:91-9. [DOI: 10.1016/j.ijrobp.2009.01.011] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2008] [Revised: 01/13/2009] [Accepted: 01/13/2009] [Indexed: 11/26/2022]
|
35
|
Reynders T, Tournel K, De Coninck P, Heymann S, Vinh-Hung V, Van Parijs H, Duchateau M, Linthout N, Gevaert T, Verellen D, Storme G. Dosimetric assessment of static and helical TomoTherapy in the clinical implementation of breast cancer treatments. Radiother Oncol 2009; 93:71-9. [DOI: 10.1016/j.radonc.2009.07.005] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2008] [Revised: 06/09/2009] [Accepted: 07/06/2009] [Indexed: 10/20/2022]
|
36
|
Rong Y, Fahner T, Welsh JS. Hypofractionated Breast and Chest Wall Irradiation Using Simultaneous in-field Boost IMRT Delivered via Helical Tomotherapy. Technol Cancer Res Treat 2008; 7:433-9. [DOI: 10.1177/153303460800700604] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Although helical tomotherapy has been described as a means of administering accelerated partial breast irradiation, its practicality in routine whole breast irradiation as part of breast conserving therapy or chest wall irradiation has been questioned. In this technical note we describe our method of whole breast or chest wall irradiation using helical tomotherapy based image-guided, hypofractionated, simultaneous in-field boost intensity modulated radiation therapy. We have observed that excellent dose-distributions can be achieved with helical tomotherapy through a careful selection of treatment planning parameters. Dose homogeneity to the whole breast and simultaneously targeted lumpectomy region appears superior to conventional “tangents” with minimal hot or cold spots. Dose-volume histogram analysis documents effective reduction of high dose to critical sensitive structures (heart and lung) although a greater volume of these non-target organs receives low dose compared to what is typical with tangential beams. Treatment planning is efficient and is usually completed within one to two hours, although physician contouring requires more time and attention than non-IMRT approaches. Pretreatment megavoltage CT (MVCT) imaging has proved invaluable in aiding set-up and engenders greater confidence that the planned IMRT dose distributions are truly being delivered. In some situations, MVCT can provide visual feedback when a seroma or overall breast volume has changed significantly since simulation, thereby identifying cases where replanning might be prudent. Treatment is brief, typically completed in 6 to 9 minutes. Initial clinical application has confirmed the feasibility and practicality of helical tomotherapy as an efficient means of administering radiation therapy for routine breast-conserving therapy and post-mastectomy chest wall irradiation. A simultaneous in-field boost technique reduces the length of the overall course by about a week thereby adding convenience and reducing costs. Further refinements of our technique are being explored and formal prospective clinical evaluation is underway.
Collapse
Affiliation(s)
- Yi Rong
- Departments of Human Oncology and Medical Physics University of Wisconsin School of Medicine and Public Health Madison, WI, USA
| | - Tasha Fahner
- UW Cancer Center - Riverview Riverview Hospital Association Wisconsin Rapids, WI 54494, USA
| | - James S. Welsh
- Departments of Human Oncology and Medical Physics University of Wisconsin School of Medicine and Public Health Madison, WI, USA
- UW Cancer Center - Riverview Riverview Hospital Association Wisconsin Rapids, WI 54494, USA
| |
Collapse
|
37
|
McIntosh A, Read PW, Khandelwal SR, Arthur DW, Turner AB, Ruchala KJ, Olivera GH, Jeswani S, Sheng K. Evaluation of coplanar partial left breast irradiation using tomotherapy-based topotherapy. Int J Radiat Oncol Biol Phys 2008; 71:603-10. [PMID: 18474316 DOI: 10.1016/j.ijrobp.2008.01.047] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2007] [Revised: 01/17/2008] [Accepted: 01/18/2008] [Indexed: 11/28/2022]
Abstract
PURPOSE To investigate the use of topotherapy for accelerated partial breast irradiation through field-design optimization and dosimetric comparison to linear accelerator-based three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT). METHODS AND MATERIALS Hypothetical 3-cm lumpectomy sites were contoured in each quadrant of a left breast by using dosimetric guidelines from the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology Group 0413 protocol. Coplanar intensity-modulated topotherapy treatment plans were optimized by using two-, three-, four-, five-, and seven-field arrangements for delivery by the tomotherapy unit with fixed gantry angles. Optimized noncoplanar five-field 3D-CRT and IMRT were compared with corresponding topotherapy plans. RESULTS On average, 99.5% +/- 0.5% of the target received 100% of the prescribed dose for all topotherapy plans. Average equivalent uniform doses ranged from 1.20-2.06, 0.79-1.76, and 0.10-0.29 Gy for heart, ipsilateral lung, and contralateral lung, respectively. Average volume of normal breast exceeding 90% of the prescription and average area of skin exceeding 35 Gy were lowest for five-field plans. Average uniformity indexes for five-field plans using 3D-CRT, IMRT, and topotherapy were 1.047, 1.050, and 1.040, respectively. Dose-volume histograms and calculated equivalent uniform doses of all three techniques illustrate clinically equivalent doses to ipsilateral breast, lung, and heart. CONCLUSIONS This dosimetric evaluation for a single patient shows that coplanar partial breast topotherapy provides good target coverage with exceptionally low dose to organs at risk. Use of more than five fields provided no additional dosimetric advantage. A comparison of five-field topotherapy to 3D-CRT and IMRT for accelerated partial breast irradiation illustrates equivalent target conformality and uniformity.
Collapse
Affiliation(s)
- Alyson McIntosh
- Department of Radiation Oncology, University of Virginia, Charlottesville, VA 22908, USA
| | | | | | | | | | | | | | | | | |
Collapse
|