Leenen JP, Schoonhoven L, Patijn GA. Wearable wireless continuous vital signs monitoring on the general ward. Curr Opin Crit Care 2024; 30:275-282. [PMID: 38690957 DOI: 10.1097/mcc.0000000000001160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/03/2024]
Abstract
PURPOSE OF REVIEW Wearable wireless sensors for continuous vital signs monitoring (CVSM) offer the potential for early identification of patient deterioration, especially in low-intensity care settings like general wards. This study aims to review advances in wearable CVSM - with a focus on the general ward - highlighting the technological characteristics of CVSM systems, user perspectives and impact on patient outcomes by exploring recent evidence. RECENT FINDINGS The accuracy of wearable sensors measuring vital signs exhibits variability, especially notable in ambulatory patients within hospital settings, and standard validation protocols are lacking. Usability of CMVS systems is critical for nurses and patients, highlighting the need for easy-to-use wearable sensors, and expansion of the number of measured vital signs. Current software systems lack integration with hospital IT infrastructures and workflow automation. Imperative enhancements involve nurse-friendly, less intrusive alarm strategies, and advanced decision support systems. Despite observed reductions in ICU admissions and Rapid Response Team calls, the impact on patient outcomes lacks robust statistical significance. SUMMARY Widespread implementation of CVSM systems on the general ward and potentially outside the hospital seems inevitable. Despite the theoretical benefits of CVSM systems in improving clinical outcomes, and supporting nursing care by optimizing clinical workflow efficiency, the demonstrated effects in clinical practice are mixed. This review highlights the existing challenges related to data quality, usability, implementation, integration, interpretation, and user perspectives, as well as the need for robust evidence to support their impact on patient outcomes, workflow and cost-effectiveness.
Collapse
Affiliation(s)
- Jobbe Pl Leenen
- Connected Care Centre, Isala, Zwolle
- Research Group IT Innovations in Healthcare, Windesheim University of Applied Sciences, Zwolle
| | - Lisette Schoonhoven
- Julius Centre for Health Sciences and Primary Care, University Medical Centre Utrecht, Utrecht University, Utrecht, The Netherlands
- School of Health Sciences, Faculty of Environmental and Life Sciences, University of Southampton, Southampton, UK
| | - Gijs A Patijn
- Connected Care Centre, Isala, Zwolle
- Department of Surgery, Isala, Zwolle, The Netherlands
| |
Collapse
|
2
|
Kant N, Garssen SH, Vernooij CA, Mauritz GJ, Koning MV, Bosch FH, Doggen CJM. Enhancing discharge decision-making through continuous monitoring in an acute admission ward: a randomized controlled trial. Intern Emerg Med 2024:10.1007/s11739-024-03582-y. [PMID: 38619713 DOI: 10.1007/s11739-024-03582-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Accepted: 03/10/2024] [Indexed: 04/16/2024]
Abstract
In Acute Admission Wards, vital signs are commonly measured only intermittently. This may result in failure to detect early signs of patient deterioration and impede timely identification of patient stability, ultimately leading to prolonged stays and avoidable hospital admissions. Therefore, continuous vital sign monitoring may improve hospital efficacy. The objective of this randomized controlled trial was to evaluate the effect of continuous monitoring on the proportion of patients safely discharged home directly from an Acute Admission Ward. Patients were randomized to either the control group, which received usual care, or the sensor group, which additionally received continuous monitoring using a wearable sensor. The continuous measurements could be considered in discharge decision-making by physicians during the daily bedside rounds. Safe discharge was defined as no unplanned readmissions, emergency department revisits or deaths, within 30 days after discharge. Additionally, length of stay, the number of Intensive Care Unit admissions and Rapid Response Team calls were assessed. In total, 400 patients were randomized, of which 394 completed follow-up, with 196 assigned to the sensor group and 198 to the control group. The proportion of patients safely discharged home was 33.2% in the sensor group and 30.8% in the control group (p = 0.62). No significant differences were observed in secondary outcomes. The trial was terminated prematurely due to futility. In conclusion, continuous monitoring did not have an effect on the proportion of patients safely discharged from an Acute Admission Ward. Implementation challenges of continuous monitoring may have contributed to the lack of effect observed. Trial registration: https://clinicaltrials.gov/ct2/show/NCT05181111 . Registered: January 6, 2022.
Collapse
Affiliation(s)
- Niels Kant
- Clinical Research Center, Rijnstate Hospital, Wagnerlaan 55, 6815 AD, Arnhem, The Netherlands
- Department of Health Technology and Services Research, Faculty of Behavioral, Management and Social Sciences, Technical Medical Centre, University of Twente, Hallenweg 5, 7522 NH, Enschede, The Netherlands
- Department of Anesthesiology, Rijnstate Hospital, Wagnerlaan 55, 6815 AD, Arnhem, The Netherlands
| | - Sjoerd H Garssen
- Clinical Research Center, Rijnstate Hospital, Wagnerlaan 55, 6815 AD, Arnhem, The Netherlands
- Department of Health Technology and Services Research, Faculty of Behavioral, Management and Social Sciences, Technical Medical Centre, University of Twente, Hallenweg 5, 7522 NH, Enschede, The Netherlands
- Department of Patient Care and Monitoring, Philips Research, High Tech Campus 34, 5656 AE, Eindhoven, The Netherlands
| | - Carlijn A Vernooij
- Department of Patient Care and Monitoring, Philips Research, High Tech Campus 34, 5656 AE, Eindhoven, The Netherlands
| | - Gert-Jan Mauritz
- Department of Emergency Medicine, Rijnstate Hospital, Wagnerlaan 55, 6815 AD, Arnhem, The Netherlands
| | - Mark V Koning
- Department of Anesthesiology, Rijnstate Hospital, Wagnerlaan 55, 6815 AD, Arnhem, The Netherlands
| | - Frank H Bosch
- Department of Internal Medicine, Rijnstate Hospital, Wagnerlaan 55, 6815 AD, Arnhem, The Netherlands
- Department of Internal Medicine, Radboudumc, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands
| | - Carine J M Doggen
- Clinical Research Center, Rijnstate Hospital, Wagnerlaan 55, 6815 AD, Arnhem, The Netherlands.
- Department of Health Technology and Services Research, Faculty of Behavioral, Management and Social Sciences, Technical Medical Centre, University of Twente, Hallenweg 5, 7522 NH, Enschede, The Netherlands.
- Department of Health Technology and Services Research, Technical Medical Centre, University of Twente, P.O. Box 217, 7500 AE, Enschede, The Netherlands.
| |
Collapse
|
3
|
Mestrom EHJ, van der Stam JA, Nienhuijs SW, de Hingh IHJT, Boer AK, van Riel NAW, Scharnhorst V, Bouwman RA. Postoperative circadian patterns in wearable sensor measured heart rate: a prospective observational study. J Clin Monit Comput 2024; 38:147-156. [PMID: 37864755 PMCID: PMC10879217 DOI: 10.1007/s10877-023-01089-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 10/04/2023] [Indexed: 10/23/2023]
Abstract
PURPOSE This study aimed to describe the 24-hour cycle of wearable sensor-obtained heart rate in patients with deterioration-free recovery and to compare it with patients experiencing postoperative deterioration. METHODS A prospective observational trial was performed in patients following bariatric or major abdominal cancer surgery. A wireless accelerometer patch (Healthdot) continuously measured postoperative heart rate, both in the hospital and after discharge, for a period of 14 days. The circadian pattern, or diurnal rhythm, in the wearable sensor-obtained heart rate was described using peak, nadir and peak-nadir excursions. RESULTS The study population consisted of 137 bariatric and 100 major abdominal cancer surgery patients. In the latter group, 39 experienced postoperative deterioration. Both surgery types showed disrupted diurnal rhythm on the first postoperative days. Thereafter, the bariatric group had significantly lower peak heart rates (days 4, 7-12, 14), lower nadir heart rates (days 3-14) and larger peak-nadir excursions (days 2, 4-14). In cancer surgery patients, significantly higher nadir (days 2-5) and peak heart rates (days 2-3) were observed prior to deterioration. CONCLUSIONS The postoperative diurnal rhythm of heart rate is disturbed by different types of surgery. Both groups showed recovery of diurnal rhythm but in patients following cancer surgery, both peak and nadir heart rates were higher than in the bariatric surgery group. Especially nadir heart rate was identified as a potential prognostic marker for deterioration after cancer surgery.
Collapse
Affiliation(s)
- Eveline H J Mestrom
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
- Department of Anesthesiology, Intensive Care & Pain Medicine, Catharina Hospital, Eindhoven, The Netherlands.
| | - Jonna A van der Stam
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Clinical laboratory, Catharina Hospital, Eindhoven, The Netherlands
- Expert Center Clinical Chemistry Eindhoven, Eindhoven, The Netherlands
| | - Simon W Nienhuijs
- Department of Surgery, Catharina Hospital, Eindhoven, The Netherlands
| | - Ignace H J T de Hingh
- Department of Surgery, Catharina Hospital, Eindhoven, The Netherlands
- GROW - School for Oncology and Developmental Biology, Maastricht University, Maastricht, The Netherlands
| | - Arjen-Kars Boer
- Clinical laboratory, Catharina Hospital, Eindhoven, The Netherlands
- Expert Center Clinical Chemistry Eindhoven, Eindhoven, The Netherlands
| | - Natal A W van Riel
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Expert Center Clinical Chemistry Eindhoven, Eindhoven, The Netherlands
- Department of Vascular Medicine, Amsterdam University Medical Centers, Amsterdam, The Netherlands
| | - Volkher Scharnhorst
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Clinical laboratory, Catharina Hospital, Eindhoven, The Netherlands
- Expert Center Clinical Chemistry Eindhoven, Eindhoven, The Netherlands
| | - R Arthur Bouwman
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- Department of Anesthesiology, Intensive Care & Pain Medicine, Catharina Hospital, Eindhoven, The Netherlands
| |
Collapse
|
4
|
van Noort HHJ, Becking-Verhaar FL, Bahlman-van Ooijen W, Pel M, van Goor H, Huisman-de Waal G. Three Years of Continuous Vital Signs Monitoring on the General Surgical Ward: Is It Sustainable? A Qualitative Study. J Clin Med 2024; 13:439. [PMID: 38256573 PMCID: PMC10816891 DOI: 10.3390/jcm13020439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 01/08/2024] [Accepted: 01/10/2024] [Indexed: 01/24/2024] Open
Abstract
Continuous monitoring of vital signs using a wireless wearable device was implemented in 2018 at a surgical care unit of an academic hospital. This study aimed at gaining insight into nurses' and patients' perspectives regarding the use and innovation of a continuous vital signs monitoring system, three years after its introduction. This qualitative study was performed in a surgical, non-intensive care unit of an academic hospital in 2021. Key-user nurses (nurses with additional training and expertise with the device) and patients were selected for semi-structured interviews, and nurses from the ward were selected for a focus group interview using a topic list. Transcripts of the audio tapes were deductively analysed using four dimensions for adoptions of information and communication technologies (ICT) devices in healthcare. The device provided feelings of safety for nurses and patients. Nurses and patients had a few issues with the device, including the size and the battery life. Nurses gained knowledge and skills in using the system for measurement and interpretations. They perceived the system as a tool to improve the recognition of clinical decline. The use of the system could be further developed regarding the technical device's characteristics, nurses' interpretation of the data and the of type of alarms, the information needs of patients, and clarification of the definition and standardization of continuous monitoring. Three years after the introduction, wireless continuous vital signs monitoring is the new standard of care according to the end-users at the general surgical ward.
Collapse
Affiliation(s)
- Harm H. J. van Noort
- Department of Surgery, Radboud University Medical Centre, 6500 HB Nijmegen, The Netherlands; (F.L.B.-V.); (W.B.-v.O.); (M.P.); (G.H.-d.W.)
| | | | | | | | - Harry van Goor
- Department of Surgery, Radboud University Medical Centre, 6500 HB Nijmegen, The Netherlands; (F.L.B.-V.); (W.B.-v.O.); (M.P.); (G.H.-d.W.)
| | | |
Collapse
|
5
|
Tran HHV, Urgessa NA, Geethakumari P, Kampa P, Parchuri R, Bhandari R, Alnasser AR, Akram A, Kar S, Osman F, Mashat GD, Mohammed L. Detection and Diagnostic Accuracy of Cardiac Arrhythmias Using Wearable Health Devices: A Systematic Review. Cureus 2023; 15:e50952. [PMID: 38249280 PMCID: PMC10800119 DOI: 10.7759/cureus.50952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Accepted: 12/22/2023] [Indexed: 01/23/2024] Open
Abstract
Photoplethysmography (PPG) is the wearable devices' most widely used technology for monitoring heart rate. The systematic review used the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) standards and guidelines. This systematic review seeks to establish the effects of wearable health devices on cardiac arrhythmias concerning their impact on the personalization of cardiac management, their refining effect on stroke prevention strategies, and their influence on research and preventive care of cardiac arrhythmias and their re-evaluation of the patient-physician relationship. The population, exposure, control, outcomes, and studies (PECOS) criteria were used in the systematic review. This review considered studies that covered the tests conducted on individuals who presented with cardiovascular diseases (CVD) and also healthy people. The intervention for studies included wearable health devices that could detect and diagnose cardiac arrhythmias. The study considered articles that reported on the personalization of cardiac management, stroke prevention strategies, influence in research and preventive care of cardiac arrhythmias, and the re-evaluation of the patient-physician relationship. Two independent researchers were used in the extraction of the data. In case of dispute, the issue was resolved using a third party. The study's quality analysis was conducted using AXIS. The management of atrial fibrillation (AF) lies heavily in the prevention of stroke. The accuracy being reported in the prediction of arrhythmias and the monitoring of heart rates makes wearable devices an efficient means to personalize health care. Personalization of health and treatment in preventing and managing arrhythmias becomes possible due to the portability of smart wearable devices. However, limitations may be observed due to the high costs incurred in their purchase and use. Using smart wearable devices for the detection of cardiac arrhythmias was very significant.
Collapse
Affiliation(s)
- Hadrian Hoang-Vu Tran
- Internal Medicine, California Institute of Behavioral Neurosciences & Psychology, Fairfield, USA
| | - Neway A Urgessa
- Research, California Institute of Behavioral Neurosciences & Psychology, Fairfield, USA
| | - Prabhitha Geethakumari
- Internal Medicine, California Institute of Behavioural Neurosciences & Psycholgy, Fairfield, USA
| | - Prathima Kampa
- Internal Medicine, California Institute of Behavioral Neurosciences & Psychology, Fairfield, USA
| | - Rakesh Parchuri
- Internal Medicine, California Institute of Behavioral Neurosciences & Psychology, Fairfield, USA
| | - Renu Bhandari
- Internal Medicine, Manipal College of Medical Sciences, Pokhara, NPL
- Internal Medicine/Family Medicine, California Institute of Behavioral Neurosciences & Psychology, Fairfield, USA
| | - Ali R Alnasser
- General Surgery, California Institute of Behavioral Neurosciences & Psychology, Fairfield, USA
| | - Aqsa Akram
- Internal Medicine, Dallah Hospital, Riyadh, SAU
- Internal Medicine, California Institute of Behavioral Neurosciences & Psychology, Fairfield, USA
| | - Saikat Kar
- Neurosciences and Psychology, California Institute of Behavioral Neurosciences & Psychology, Fairfield, USA
| | - Fatema Osman
- Internal Medicine, California Institute of Behavioral Neurosciences & Psychology, Fairfield, USA
| | - Ghadi D Mashat
- Pediatrics, California Institute of Behavioral Neurosciences & Psychology, Fairfield, USA
| | - Lubna Mohammed
- Internal Medicine, California Institute of Behavioral Neurosciences & Psychology, Fairfield, USA
| |
Collapse
|
6
|
Kjærgaard K, Mølgaard J, Rasmussen SM, Meyhoff CS, Aasvang EK. The effect of technical filtering and clinical criteria on alert rates from continuous vital sign monitoring in the general ward. Hosp Pract (1995) 2023; 51:295-302. [PMID: 38126772 DOI: 10.1080/21548331.2023.2298185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 12/19/2023] [Indexed: 12/23/2023]
Abstract
OBJECTIVES Continuous vital sign monitoring at the general hospital ward has major potential advantages over intermittent monitoring but generates many alerts with risk of alert fatigue. We hypothesized that the number of alerts would decrease using different filters. METHODS This study was an exploratory analysis of the alert reducing effect from adding two different filters to continuously collected vital sign data (peripheral oxygen saturation, blood pressure, heart rate, and respiratory rate) in patients admitted after major surgery or severe medical disease. Filtered data were compared to data without artifact removal. Filter one consists of artifact removal, filter two consists of artifact removal plus duration criteria adjusted for severity of vital sign deviation. Alert thresholds were based on the National Early Warning Score (NEWS) threshold. RESULTS A population of 716 patients admitted for severe medical disease or major surgery with continuous wireless vital sign monitoring at the general ward with a mean monitoring time of 75.8 h, were included for the analysis. Without artifact removal, we found a median of 137 [IQR: 87-188] alerts per patient/day, artifact removal resulted in a median of 101 [IQR: 56-160] alerts per patient/day and with artifact removal combined with a duration-severity criterion, we found a median of 19 [IQR: 9-34] alerts per patient/day. Reduction of alerts was 86.4% (p < 0.001) for values without artifact removal (137 alerts) vs. the duration criteria and a reduction (19 alerts) of 81.5% (p < 0.001) for the criteria with artifact removal (101 alerts) vs. the duration criteria (19 alerts). CONCLUSION We conclude that a combination of artifact removal and duration-severity criteria approach substantially reduces alerts generated by continuous vital sign monitoring.
Collapse
Affiliation(s)
- Karoline Kjærgaard
- Department of Anesthesiology, Centre for Cancer and Organ Diseases, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark
| | - Jesper Mølgaard
- Department of Anesthesiology, Centre for Cancer and Organ Diseases, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark
| | - Søren M Rasmussen
- Digital Health Section, Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Christian Sylvest Meyhoff
- Department of Anesthesia and Intensive Care, Copenhagen University Hospital - Bispebjerg and Frederiksberg, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Eske Kvanner Aasvang
- Department of Anesthesiology, Centre for Cancer and Organ Diseases, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
7
|
Leenen JPL, Rasing HJM, Kalkman CJ, Schoonhoven L, Patijn GA. Process Evaluation of a Wireless Wearable Continuous Vital Signs Monitoring Intervention in 2 General Hospital Wards: Mixed Methods Study. JMIR Nurs 2023; 6:e44061. [PMID: 37140977 DOI: 10.2196/44061] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 01/25/2023] [Accepted: 03/27/2023] [Indexed: 05/05/2023] Open
Abstract
BACKGROUND Continuous monitoring of vital signs (CMVS) using wearable wireless sensors is increasingly available to patients in general wards and can improve outcomes and reduce nurse workload. To assess the potential impact of such systems, successful implementation is important. We developed a CMVS intervention and implementation strategy and evaluated its success in 2 general wards. OBJECTIVE We aimed to assess and compare intervention fidelity in 2 wards (internal medicine and general surgery) of a large teaching hospital. METHODS A mixed methods sequential explanatory design was used. After thorough training and preparation, CMVS was implemented-in parallel with the standard intermittent manual measurements-and executed for 6 months in each ward. Heart rate and respiratory rate were measured using a chest-worn wearable sensor, and vital sign trends were visualized on a digital platform. Trends were routinely assessed and reported each nursing shift without automated alarms. The primary outcome was intervention fidelity, defined as the proportion of written reports and related nurse activities in case of deviating trends comparing early (months 1-2), mid- (months 3-4), and late (months 5-6) implementation periods. Explanatory interviews with nurses were conducted. RESULTS The implementation strategy was executed as planned. A total of 358 patients were included, resulting in 45,113 monitored hours during 6142 nurse shifts. In total, 10.3% (37/358) of the sensors were replaced prematurely because of technical failure. Mean intervention fidelity was 70.7% (SD 20.4%) and higher in the surgical ward (73.6%, SD 18.1% vs 64.1%, SD 23.7%; P<.001). Fidelity decreased over the implementation period in the internal medicine ward (76%, 57%, and 48% at early, mid-, and late implementation, respectively; P<.001) but not significantly in the surgical ward (76% at early implementation vs 74% at midimplementation [P=.56] vs 70.7% at late implementation [P=.07]). No nursing activities were needed based on vital sign trends for 68.7% (246/358) of the patients. In 174 reports of 31.3% (112/358) of the patients, observed deviating trends led to 101 additional bedside assessments of patients and 73 consultations by physicians. The main themes that emerged during interviews (n=21) included the relative priority of CMVS in nurse work, the importance of nursing assessment, the relatively limited perceived benefits for patient care, and experienced mediocre usability of the technology. CONCLUSIONS We successfully implemented a system for CMVS at scale in 2 hospital wards, but our results show that intervention fidelity decreased over time, more in the internal medicine ward than in the surgical ward. This decrease appeared to depend on multiple ward-specific factors. Nurses' perceptions regarding the value and benefits of the intervention varied. Implications for optimal implementation of CMVS include engaging nurses early, seamless integration into electronic health records, and sophisticated decision support tools for vital sign trend interpretation.
Collapse
Affiliation(s)
- Jobbe P L Leenen
- Connected Care Center, Isala, Zwolle, Netherlands
- Isala Academy, Isala, Zwolle, Netherlands
- Department of Surgery, Isala, Zwolle, Netherlands
| | | | - Cor J Kalkman
- Department of Anaesthesiology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Lisette Schoonhoven
- University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht University, Utrecht, Netherlands
- School of Health Sciences, Faculty of Environmental and Life Sciences, University of Southampton, Southampton, United Kingdom
| | - Gijsbert A Patijn
- Connected Care Center, Isala, Zwolle, Netherlands
- Department of Surgery, Isala, Zwolle, Netherlands
| |
Collapse
|
8
|
Aagaard N, Larsen AT, Aasvang EK, Meyhoff CS. The impact of continuous wireless monitoring on adverse device effects in medical and surgical wards: a review of current evidence. J Clin Monit Comput 2023; 37:7-17. [PMID: 35917046 DOI: 10.1007/s10877-022-00899-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 07/16/2022] [Indexed: 01/25/2023]
Abstract
Novel technologies allow continuous wireless monitoring systems (CWMS) to measure vital signs and these systems might be favorable compared to intermittent monitoring regarding improving outcomes. However, device safety needs to be validated because uncertain evidence challenges the clinical implementation of CWMS. This review investigates the frequency of device-related adverse events in patients monitored with CWMS in general hospital wards. Systematic literature searches were conducted in PubMed and Embase. We included trials of adult patients in general hospital wards monitored with CWMS. Our primary outcome was the frequency of unanticipated serious adverse device effects (USADEs). Secondary outcomes were adverse device effects (ADEs) and serious adverse device effects (SADE). Data were extracted from eligible studies and descriptive statistics were applied to analyze the data. Seven studies were eligible for inclusion with a total of 1485 patients monitored by CWMS. Of these patients, 54 patients experienced ADEs (3.6%, 95% CI 2.8-4.7%) and no USADEs or SADEs were reported (0%, 95% CI 0-0.31%). The studies of the SensiumVitals® patch, the iThermonitor, and the ViSi Mobile® device reported 28 (9%), 25 (5%), and 1 (3%) ADEs, respectively. No ADEs were reported using the HealthPatch, WARD 24/7 system, or Coviden Alarm Management. Current evidence suggests that CWMS are safe to use but systematic reporting of all adverse device effects is warranted.
Collapse
Affiliation(s)
- Nikolaj Aagaard
- Department of Anaesthesia and Intensive Care, Copenhagen University Hospital - Bispebjerg and Frederiksberg, Copenhagen, Denmark.
| | | | - Eske K Aasvang
- Department of Anesthesia, CKO, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Christian S Meyhoff
- Department of Anaesthesia and Intensive Care, Copenhagen University Hospital - Bispebjerg and Frederiksberg, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
9
|
Fumagalli Romario U, de Pascale S, Colombo S, Attanasio A, Sabbatini A, Sandrin F. Esophagectomy-prevention of complications-tips and tricks for the preoperative, intraoperative and postoperative stage. Updates Surg 2023; 75:343-355. [PMID: 35851675 DOI: 10.1007/s13304-022-01332-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Accepted: 07/06/2022] [Indexed: 01/24/2023]
Abstract
Esophagectomy still remains the mainstay of treatment for localized esophageal cancer. Many progresses have been made in the technique of esophagectomy in the last decades but the overall morbidity for this operation remains formidable. Postoperative complication and mortality rate after esophagectomy are significant; anastomotic leak has an incidence of 11,4%. The occurrence of a complication is a significant negative prognostic factor for long term survival and is also linked to longer postoperative stay, a lower quality of life, increased hospital costs. Preventing the occurrence of postoperative morbidity and reducing associated postoperative mortality rate is a major goal for surgeons experienced in resective esophageal surgery. Many details of pre, intra and postoperative care for patients undergoing esophagectomy need to be shared among the professionals taking care of these patients (oncologists, dieticians, physiotherapists, surgeons, nurses, anesthesiologists, gastroenterologists) in order to improve the short and long term clinical results.
Collapse
|
10
|
Association Between Postoperative Complications and Long-term Survival After Non-cardiac Surgery Among Veterans. Ann Surg 2023; 277:e24-e32. [PMID: 33630458 DOI: 10.1097/sla.0000000000004749] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To evaluate the relationship between postoperative complications and long-term survival. SUMMARY AND BACKGROUND Postoperative complications remain a significant driver of healthcare costs and are associated with increased perioperative mortality, yet the extent to which they are associated with long-term survival is unclear. METHODS National cohort study of Veterans who underwent non-cardiac surgery using data from the Veterans Affairs Surgical Quality Improvement Program (2011-2016). Patients were classified as having undergone outpatient, low-risk inpatient, or high-risk inpatient surgery. Patients were categorized based on number and type of complications. The association between the number of complications (or the specific type of complication) and risk of death was evaluated using multivariable Cox regression with robust standard errors using a 90-day survival landmark. RESULTS Among 699,002 patients, complication rates were 3.0%, 6.1%, and 18.3% for outpatient, low-risk inpatient, and high-risk inpatient surgery, respectively. There was a dose-response relationship between an increasing number of complications and overall risk of death in all operative settings [outpatient surgery: no complications (ref); one-hazard ratio (HR) 1.30 (1.23 - 1.38); multiple-HR 1.61 (1.46 - 1.78); low-risk inpatient surgery: one-HR 1.34 (1.26 - 1.41); multiple-HR 1.69 (1.55 - 1.85); high-risk inpatient surgery: one-HR 1.14 (1.10 - 1.18); multiple-HR 1.42 (1.36 - 1.48)]. All complication types were associated with risk of death in at least 1 operative setting, and pulmonary complications, sepsis, and clostridium difficile colitis were associated with higher risk of death across all settings. Conclusions: Postoperative complications have an adverse impact on patients' long-term survival beyond the immediate postoperative period. Although most research and quality improvement initiatives primarily focus on the perioperative impact of complications, these data suggest they also have important longer-term implications that merit further investigation.
Collapse
|
11
|
van der Stam JA, Mestrom EHJ, Nienhuijs SW, de Hingh IHJT, Boer AK, van Riel NAW, de Groot KTJ, Verhaegh W, Scharnhorst V, Bouwman RA. A wearable patch based remote early warning score (REWS) in major abdominal cancer surgery patients. Eur J Surg Oncol 2023; 49:278-284. [PMID: 36085116 DOI: 10.1016/j.ejso.2022.08.034] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 07/30/2022] [Accepted: 08/26/2022] [Indexed: 01/24/2023] Open
Abstract
INTRODUCTION The shift toward remote patient monitoring methods to detect clinical deterioration requires testing of wearable devices in real-life clinical settings. This study aimed to develop a remote early warning scoring (REWS) system based on continuous measurements using a wearable device, and compare its diagnostic performance for the detection of deterioration to the diagnostic performance of the conventional modified early warning score (MEWS). MATERIALS AND METHODS The study population of this prospective, single center trial consisted of patients who underwent major abdominal cancer surgery and were monitored using routine in-hospital spotcheck measurements of the vital parameters. Heart and respiratory rates were measured continuously using a wireless accelerometer patch (HealthDot). The prediction by MEWS of deterioration toward a complication graded Clavien-Dindo of 2 or higher was compared to the REWS derived from continuous measurements by the wearable patch. MAIN RESULTS A total of 103 patients and 1909 spot-check measurements were included in the analysis. Postoperative deterioration was observed in 29 patients. For both EWS systems, the sensitivity (MEWS: 0.20 95% CI: [0.13-0.29], REWS: 0.20 95% CI: [0.13-0.29]) and specificity (MEWS: 0.96 95% CI: [0.95-0.97], REWS: 0.96 95% CI: [0.95-0.97]) were assessed. CONCLUSIONS The diagnostic value of the REWS method, based on continuous measurements of the heart and respiratory rates, is comparable to that of the MEWS in patients following major abdominal cancer surgery. The wearable patch could detect the same amount of deteriorations, without requiring manual spot check measurements.
Collapse
Affiliation(s)
- Jonna A van der Stam
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Clinical Laboratory, Catharina Hospital, Eindhoven, the Netherlands; Expert Center Clinical Chemistry Eindhoven, Eindhoven, the Netherlands.
| | - Eveline H J Mestrom
- Department of Anesthesiology, Intensive Care & Pain Medicine, Catharina Hospital, Eindhoven, the Netherlands
| | - Simon W Nienhuijs
- Department of Surgery, Catharina Hospital, Eindhoven, the Netherlands
| | - Ignace H J T de Hingh
- Department of Surgery, Catharina Hospital, Eindhoven, the Netherlands; GROW - School for Oncology and Developmental Biology, Maastricht University, Maastricht, the Netherlands
| | - Arjen-Kars Boer
- Clinical Laboratory, Catharina Hospital, Eindhoven, the Netherlands; Expert Center Clinical Chemistry Eindhoven, Eindhoven, the Netherlands
| | - Natal A W van Riel
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Expert Center Clinical Chemistry Eindhoven, Eindhoven, the Netherlands; Department of Vascular Medicine, Amsterdam University Medical Centers, Amsterdam, the Netherlands
| | - Koen T J de Groot
- Department of AI, Data Science & Digital Twin, Philips Research, Eindhoven, the Netherlands
| | - Wim Verhaegh
- Department of AI, Data Science & Digital Twin, Philips Research, Eindhoven, the Netherlands
| | - Volkher Scharnhorst
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Clinical Laboratory, Catharina Hospital, Eindhoven, the Netherlands; Expert Center Clinical Chemistry Eindhoven, Eindhoven, the Netherlands
| | - R Arthur Bouwman
- Department of Anesthesiology, Intensive Care & Pain Medicine, Catharina Hospital, Eindhoven, the Netherlands; Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| |
Collapse
|
12
|
Choi A, Chung K, Chung SP, Lee K, Hyun H, Kim JH. Advantage of Vital Sign Monitoring Using a Wireless Wearable Device for Predicting Septic Shock in Febrile Patients in the Emergency Department: A Machine Learning-Based Analysis. SENSORS (BASEL, SWITZERLAND) 2022; 22:7054. [PMID: 36146403 PMCID: PMC9504566 DOI: 10.3390/s22187054] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 09/02/2022] [Accepted: 09/13/2022] [Indexed: 06/16/2023]
Abstract
Intermittent manual measurement of vital signs may not rapidly predict sepsis development in febrile patients admitted to the emergency department (ED). We aimed to evaluate the predictive performance of a wireless monitoring device that continuously measures heart rate (HR) and respiratory rate (RR) and a machine learning analysis in febrile but stable patients in the ED. We analysed 468 patients (age, ≥18 years; training set, n = 277; validation set, n = 93; test set, n = 98) having fever (temperature >38 °C) and admitted to the isolation care unit of the ED. The AUROC of the fragmented model with device data was 0.858 (95% confidence interval [CI], 0.809−0.908), and that with manual data was 0.841 (95% CI, 0.789−0.893). The AUROC of the accumulated model with device data was 0.861 (95% CI, 0.811−0.910), and that with manual data was 0.853 (95% CI, 0.803−0.903). Fragmented and accumulated models with device data detected clinical deterioration in febrile patients at risk of septic shock 9 h and 5 h 30 min earlier, respectively, than those with manual data. Continuous vital sign monitoring using a wearable device could accurately predict clinical deterioration and reduce the time to recognise potential clinical deterioration in stable ED patients with fever.
Collapse
Affiliation(s)
- Arom Choi
- Department of Emergency Medicine, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea
| | - Kyungsoo Chung
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea
| | - Sung Phil Chung
- Department of Emergency Medicine, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea
| | - Kwanhyung Lee
- AITRICS, 28 Hyoryeong-ro 77-gil, Seocho-gu, Seoul 06627, Korea
| | - Heejung Hyun
- AITRICS, 28 Hyoryeong-ro 77-gil, Seocho-gu, Seoul 06627, Korea
| | - Ji Hoon Kim
- Department of Emergency Medicine, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea
| |
Collapse
|
13
|
van Ede E, Scheerhoorn J, Bonomi A, Buise M, Bouwman R, Nienhuijs S. “Continuous remote monitoring in post bariatric surgery patients: development of an early warning protocol”. Surg Obes Relat Dis 2022; 18:1298-1303. [DOI: 10.1016/j.soard.2022.06.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 06/02/2022] [Accepted: 06/12/2022] [Indexed: 10/31/2022]
|
14
|
Feasibility of wireless continuous monitoring of vital signs without using alarms on a general surgical ward: A mixed methods study. PLoS One 2022; 17:e0265435. [PMID: 35286354 PMCID: PMC8947816 DOI: 10.1371/journal.pone.0265435] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Accepted: 03/01/2022] [Indexed: 11/19/2022] Open
Abstract
Background Wireless continuous vital sign monitoring by wearable devices have recently become available for patients on general wards to promote timely detection of clinical deterioration. Many continuous monitoring systems use conventional threshold alarm settings to alert nurses in case of deviating vital signs. However, frequent false alarms often lead to alarm fatigue and inefficiencies in the workplace. The aim of this study was to determine the feasibility of continuous vital sign monitoring without the use of alarms, thereby exclusively relying on interval trend monitoring. Methods This explanatory sequential mixed methods study was conducted at an abdominal surgical ward of a tertiary teaching hospital. Heart rate and respiratory rate of patients were measured every minute by a wearable sensor. Trends were visualized and assessed six times per day by nurses and once a day by doctors during morning rounds. Instead of using alarms we focused exclusively on regular vital sign trend analysis by nurses and doctors. Primary outcome was feasibility in terms of acceptability by professionals, assessed by the Usefulness, Satisfaction and Ease of Use questionnaire and further explored in two focus groups, as well as fidelity. Results A total of 56 patients were monitored and in 80.5% (n = 536) of nurses’ work shifts the trends assessments were documented. All deviating trends (n = 17) were recognized in time. Professionals (N = 46) considered continuous monitoring satisfying (4.8±1.0 on a 1–7 Likert-scale) and were willing to use the technology. Although insight into vital sign trends allowed faster anticipation and action upon changed patient status, professionals were neutral about usefulness (4.4±1.0). They found continuous monitoring easy to use (4.7±0.8) and easy to learn (5.3±1.0) but indicated the need for gaining practical experience. Nurses considered the use of alarms for deviating vital signs unnecessary, when trends were regularly assessed and reported. Conclusion We demonstrated that continuous vital signs trend monitoring without using alarms was feasible in the general ward setting, thereby avoiding unnecessary alarms and preventing alarm fatigue. When monitoring in a general ward setting, the standard use of alarms may therefore be reconsidered.
Collapse
|
15
|
Wells CI, Xu W, Penfold JA, Keane C, Gharibans AA, Bissett IP, O’Grady G. OUP accepted manuscript. BJS Open 2022; 6:6564495. [PMID: 35388891 PMCID: PMC8988014 DOI: 10.1093/bjsopen/zrac031] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 02/03/2022] [Accepted: 02/13/2022] [Indexed: 11/28/2022] Open
Abstract
Background Wearable devices have been proposed as a novel method for monitoring patients after surgery to track recovery, identify complications early, and improve surgical safety. Previous studies have used a heterogeneous range of devices, methods, and analyses. This review aimed to examine current methods and wearable devices used for monitoring after abdominal surgery and identify knowledge gaps requiring further investigation. Methods A scoping review was conducted given the heterogeneous nature of the evidence. MEDLINE, EMBASE, and Scopus databases were systematically searched. Studies of wearable devices for monitoring of adult patients within 30 days after abdominal surgery were eligible for inclusion. Results A total of 78 articles from 65 study cohorts, with 5153 patients were included. Thirty-one different wearable devices were used to measure vital signs, physiological measurements, or physical activity. The duration of postoperative wearable device use ranged from 15 h to 3 months after surgery. Studies mostly focused on physical activity metrics (71.8 per cent). Continuous vital sign measurement and physical activity tracking both showed promise for detecting postoperative complications earlier than usual care, but conclusions were limited by poor device precision, adherence, occurrence of false alarms, data transmission problems, and retrospective data analysis. Devices were generally well accepted by patients, with high levels of acceptance, comfort, and safety. Conclusion Wearable technology has not yet realized its potential to improve postoperative monitoring. Further work is needed to overcome technical limitations, improve precision, and reduce false alarms. Prospective assessment of efficacy, using an intention-to-treat approach should be the focus of further studies.
Collapse
Affiliation(s)
- Cameron I. Wells
- Correspondence to: Cameron Wells, Department of Surgery, University of Auckland, Private Bag 92019, Auckland Mail Centre 1142, New Zealand (e-mail:)
| | - William Xu
- Department of Surgery, The University of Auckland, Auckland, New Zealand
| | - James A. Penfold
- Department of Surgery, The University of Auckland, Auckland, New Zealand
| | - Celia Keane
- Department of Surgery, The University of Auckland, Auckland, New Zealand
| | - Armen A. Gharibans
- Department of Surgery, The University of Auckland, Auckland, New Zealand
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Ian P. Bissett
- Department of Surgery, The University of Auckland, Auckland, New Zealand
- Department of Surgery, Auckland District Health Board, Auckland, New Zealand
| | - Greg O’Grady
- Department of Surgery, The University of Auckland, Auckland, New Zealand
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
- Department of Surgery, Auckland District Health Board, Auckland, New Zealand
| |
Collapse
|
16
|
Rauwerdink A, Kasteleyn MJ, Chavannes NH, Schijven MP. Successes of and Lessons From the First Joint eHealth Program of the Dutch University Hospitals: Evaluation Study. J Med Internet Res 2021. [PMID: 34842536 DOI: 10.1016/j.ceh.2020.12.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND A total of 8 Dutch university hospitals are at the forefront of contributing meaningfully to a future-proof health care system. To stimulate nationwide collaboration and knowledge-sharing on the topic of evidence-based eHealth, the Dutch university hospitals joined forces from 2016 to 2019 with the first Citrien Fund (CF) program eHealth; 29 eHealth projects with various subjects and themes were selected, supported, and evaluated. To determine the accomplishment of the 10 deliverables for the CF program eHealth and to contribute to the theory and practice of formative evaluation of eHealth in general, a comprehensive evaluation was deemed essential. OBJECTIVE The first aim of this study is to evaluate whether the 10 deliverables of the CF program eHealth were accomplished. The second aim is to evaluate the progress of the 29 eHealth projects to determine the barriers to and facilitators of the development of the CF program eHealth projects. METHODS To achieve the first aim of this study, an evaluation study was carried out using an adapted version of the Commonwealth Scientific and Industrial Research Organization framework. A mixed methods study, consisting of a 2-part questionnaire and semistructured interviews, was conducted to analyze the second aim of the study. RESULTS The 10 deliverables of the CF program eHealth were successfully achieved. The program yielded 22 tangible eHealth solutions, and significant knowledge on the development and use of eHealth solutions. We have learned that the patient is enthusiastic about accessing and downloading their own medical data but the physicians are more cautious. It was not always possible to implement the Dutch set of standards for interoperability, owing to a lack of information technology (IT) capacities. In addition, more attention needed to be paid to patients with low eHealth skills, and education in such cases is important. The eHealth projects' progress aspects such as planning, IT services, and legal played an important role in the success of the 29 projects. The in-depth interviews illustrated that a novel eHealth solution should fulfill a need, that partners already having the knowledge and means to accelerate development should be involved, that clear communication with IT developers and other stakeholders is crucial, and that having a dedicated project leader with sufficient time is of utmost importance for the success of a project. CONCLUSIONS The 8 Dutch university hospitals were able to collaborate successfully and stimulate through a bottom-up approach, nationwide eHealth development and knowledge-sharing. In total, 22 tangible eHealth solutions were developed, and significant eHealth knowledge about their development and use was shared. The eHealth projects' progress aspects such as planning, IT services, and legal played an important role in the successful progress of the projects and should therefore be closely monitored when developing novel eHealth solutions. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID) RR2-10.1016/j.ceh.2020.12.002.
Collapse
Affiliation(s)
- Anneloek Rauwerdink
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | - Marise J Kasteleyn
- Department of Public Health and Primary Care, Leiden University Medical Centre, Leiden, Netherlands
- National eHealth Living Lab, Leiden, Netherlands
| | - Niels H Chavannes
- Department of Public Health and Primary Care, Leiden University Medical Centre, Leiden, Netherlands
- National eHealth Living Lab, Leiden, Netherlands
| | - Marlies P Schijven
- Department of Surgery, Amsterdam Gastroenterology and Metabolism, Amsterdam UMC, Amsterdam, Netherlands
- Citrien Fund program eHealth, Amsterdam, Netherlands
| |
Collapse
|
17
|
Rauwerdink A, Kasteleyn MJ, Chavannes NH, Schijven MP. Successes of and Lessons From the First Joint eHealth Program of the Dutch University Hospitals: Evaluation Study. J Med Internet Res 2021; 23:e25170. [PMID: 34842536 PMCID: PMC8663485 DOI: 10.2196/25170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 02/23/2021] [Accepted: 07/27/2021] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND A total of 8 Dutch university hospitals are at the forefront of contributing meaningfully to a future-proof health care system. To stimulate nationwide collaboration and knowledge-sharing on the topic of evidence-based eHealth, the Dutch university hospitals joined forces from 2016 to 2019 with the first Citrien Fund (CF) program eHealth; 29 eHealth projects with various subjects and themes were selected, supported, and evaluated. To determine the accomplishment of the 10 deliverables for the CF program eHealth and to contribute to the theory and practice of formative evaluation of eHealth in general, a comprehensive evaluation was deemed essential. OBJECTIVE The first aim of this study is to evaluate whether the 10 deliverables of the CF program eHealth were accomplished. The second aim is to evaluate the progress of the 29 eHealth projects to determine the barriers to and facilitators of the development of the CF program eHealth projects. METHODS To achieve the first aim of this study, an evaluation study was carried out using an adapted version of the Commonwealth Scientific and Industrial Research Organization framework. A mixed methods study, consisting of a 2-part questionnaire and semistructured interviews, was conducted to analyze the second aim of the study. RESULTS The 10 deliverables of the CF program eHealth were successfully achieved. The program yielded 22 tangible eHealth solutions, and significant knowledge on the development and use of eHealth solutions. We have learned that the patient is enthusiastic about accessing and downloading their own medical data but the physicians are more cautious. It was not always possible to implement the Dutch set of standards for interoperability, owing to a lack of information technology (IT) capacities. In addition, more attention needed to be paid to patients with low eHealth skills, and education in such cases is important. The eHealth projects' progress aspects such as planning, IT services, and legal played an important role in the success of the 29 projects. The in-depth interviews illustrated that a novel eHealth solution should fulfill a need, that partners already having the knowledge and means to accelerate development should be involved, that clear communication with IT developers and other stakeholders is crucial, and that having a dedicated project leader with sufficient time is of utmost importance for the success of a project. CONCLUSIONS The 8 Dutch university hospitals were able to collaborate successfully and stimulate through a bottom-up approach, nationwide eHealth development and knowledge-sharing. In total, 22 tangible eHealth solutions were developed, and significant eHealth knowledge about their development and use was shared. The eHealth projects' progress aspects such as planning, IT services, and legal played an important role in the successful progress of the projects and should therefore be closely monitored when developing novel eHealth solutions. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID) RR2-10.1016/j.ceh.2020.12.002.
Collapse
Affiliation(s)
- Anneloek Rauwerdink
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | - Marise J Kasteleyn
- Department of Public Health and Primary Care, Leiden University Medical Centre, Leiden, Netherlands
- National eHealth Living Lab, Leiden, Netherlands
| | - Niels H Chavannes
- Department of Public Health and Primary Care, Leiden University Medical Centre, Leiden, Netherlands
- National eHealth Living Lab, Leiden, Netherlands
| | - Marlies P Schijven
- Department of Surgery, Amsterdam Gastroenterology and Metabolism, Amsterdam UMC, Amsterdam, Netherlands
- Citrien Fund program eHealth, Amsterdam, Netherlands
| |
Collapse
|
18
|
de Ree R, Willemsen J, Te Grotenhuis G, de Ree R, Kolkert J, Peppelman M. Continuous monitoring in COVID-19 care: a retrospective study in time of crisis. JAMIA Open 2021; 4:ooab030. [PMID: 34136756 PMCID: PMC8083333 DOI: 10.1093/jamiaopen/ooab030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 03/11/2021] [Accepted: 04/09/2021] [Indexed: 11/13/2022] Open
Abstract
Background A new monitoring system was implemented to support nursing staff and physicians on the COVID-19 ward. This system was designed to remotely monitor vital signs, to calculate an automated Early Warning Score, and to help identify patients at risk of deterioration. Methods Hospitalized patients who tested positive for SARS-CoV-2 were connected to 2 wireless sensors measuring vital signs. Patients were divided into 2 groups based on the occurrence of adverse events during hospitalization. Heart and respiratory rate were monitored continuously and an automated EWS was calculated every 5 minutes. Data were compared between groups. Results Prior to the occurrence of adverse events, significantly higher median heart and respiration rate and significantly lower median SPO2 values were observed. Mean and median automated EWS were significantly higher in patients with an adverse event. Conclusion Continuous monitoring systems might help to detect clinical deterioration in COVID-19 patients at an earlier stage.
Collapse
Affiliation(s)
- Roy de Ree
- Department of Health Innovation, Slingeland Hospital, Doetinchem, Gelderland, The Netherlands
| | - Jorn Willemsen
- Department of Health Innovation, Slingeland Hospital, Doetinchem, Gelderland, The Netherlands
| | - Gilbert Te Grotenhuis
- Department of Health Innovation, Slingeland Hospital, Doetinchem, Gelderland, The Netherlands
| | - Rick de Ree
- Department of Health Innovation, Slingeland Hospital, Doetinchem, Gelderland, The Netherlands
| | - Joé Kolkert
- Department of Surgery, Slingeland Hospital, Doetinchem, Gelderland, The Netherlands
| | - Malou Peppelman
- Department of Health Innovation, Slingeland Hospital, Doetinchem, Gelderland, The Netherlands
| |
Collapse
|
19
|
Safavi KC, Deng H, Driscoll W, Nikolov M, Tolia K, Wiener-Kronish JP. A Remote Surveillance Platform to Monitor General Care Ward Surgical Patients for Acute Physiologic Deterioration. Anesth Analg 2021; 133:933-939. [PMID: 33830955 PMCID: PMC8415733 DOI: 10.1213/ane.0000000000005530] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND The traditional paradigm of hospital surgical ward care consists of episodic bedside visits by providers with periodic perusals of the patient's electronic health record (EHR). Vital signs and laboratory results are directly pushed to the EHR but not to providers themselves. Results that require intervention may not be recognized for hours. Remote surveillance programs continuously monitor electronic data and provide automatic alerts that can be routed to multidisciplinary providers. Such programs have not been explored in surgical general care wards. METHODS We performed a quality improvement observational study of otolaryngology and ophthalmology patients on a general care ward from October 2017 to March 2019 during nighttime hours (17:00-07:00). The study was initiated due to the loss of on-site anesthesiology resources that historically helped respond to acute physiologic deterioration events. We implemented a remote surveillance software program to continuously monitor patients for severe vital signs and laboratory abnormalities and automatically alert the ward team and a remote critical care anesthesiology team. The primary end point was the true positive rate, defined as the proportion of alerts that were associated with a downstream action that changed the care of the patient. This was determined using systematic chart review. The secondary end point, as a measure of alarm fatigue, was the average number of alerts per clinician shift. RESULTS The software monitored 3926 hospital visits and analyzed 1,560,999 vitals signs and 16,635 laboratories. It generated 151 alerts, averaging 2.6 alerts per week. Of these, 143 (94.7%) were numerically accurate and 8 (5.3%) were inaccurate. Hypoxemia with oxygen saturation <88% was the most common etiology (92, 63%) followed by tachycardia >130 beats per minute (19, 13.3%). Among the accurate alerts, 133 (88.1%) were true positives with an associated clinical action. Actions included a change in management 113 (67.7%), new diagnostic test 26 (15.6%), change in discharge planning 20 (12.0%), and change in level of care to the intensive care unit (ICU) 8 (4.8%). As a measure of alarm fatigue, there were 0.4 alerts per clinician shift. CONCLUSIONS In a surgical general care ward, a remote surveillance software program that continually and automatically monitors physiologic data streams from the EHR and alerts multidisciplinary providers for severe derangements provided highly actionable alarms at a rate that is unlikely to cause alarm fatigue. Such programs are feasible and could be used to change the paradigm of monitoring.
Collapse
Affiliation(s)
- Kyan C Safavi
- From the Department of Anesthesiology, Critical Care and Pain Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Hao Deng
- From the Department of Anesthesiology, Critical Care and Pain Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts.,Bloomberg-School of Public Health, Johns Hopkins University, Baltimore, Maryland
| | - William Driscoll
- From the Department of Anesthesiology, Critical Care and Pain Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Milcho Nikolov
- From the Department of Anesthesiology, Critical Care and Pain Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Kalpan Tolia
- From the Department of Anesthesiology, Critical Care and Pain Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Jeanine P Wiener-Kronish
- From the Department of Anesthesiology, Critical Care and Pain Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
20
|
Leenen JPL, Dijkman EM, van Dijk JD, van Westreenen HL, Kalkman C, Schoonhoven L, Patijn GA. Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study. BMJ Open 2021; 11:e042735. [PMID: 33597138 PMCID: PMC7893648 DOI: 10.1136/bmjopen-2020-042735] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
OBJECTIVE To determine feasibility, in terms of acceptability and system fidelity, of continuous vital signs monitoring in abdominal surgery patients on a general ward. DESIGN Observational cohort study. SETTING Tertiary teaching hospital. PARTICIPANTS Postoperative abdominal surgical patients (n=30) and nurses (n=23). INTERVENTIONS Patients were continuously monitored with the SensiumVitals wearable device until discharge in addition to usual care, which is intermittent Modified Early Warning Score measurements. Heart rate, respiratory rate and axillary temperature were monitored every 2 min. Values and trends were visualised and alerts sent to the nurses. OUTCOMES System fidelity was measured by analysis of the monitoring data. Acceptability by patients and nurses was assessed using questionnaires. RESULTS Thirty patients were monitored for a median duration of 81 hours (IQR 47-143) per patient, resulting in 115 217 measurements per parameter. In total, 19% (n=21 311) of heart rate, 51% (n=59 184) of respiratory rate and 9% of temperature measurements showed artefacts (n=10 269). The system algorithm sent 972 alerts (median alert rate of 4.5 per patient per day), of which 90.3% (n=878) were system alerts and 9.7% (n=94) were vital sign alerts. 35% (n=33) of vital sign alerts were true positives. 93% (n=25) of patients rated the patch as comfortable, 67% (n=18) felt safer and 89% (n=24) would like to wear it next time in the hospital. Nurses were neutral about usefulness, with a median score of 3.5 (IQR 3.1-4) on a 7-point Likert scale, ease of use 3.7 (IQR 3.2-4.8) and satisfaction 3.7 (IQR 3.2-4.8), but agreed on ease of learning at 5.0 (IQR 4.0-5.8). Neutral scores were mostly related to the perceived limited fidelity of the system. CONCLUSIONS Continuous monitoring of vital signs with a wearable device was well accepted by patients. Nurses' ratings were highly variable, resulting in on average neutral attitude towards remote monitoring. Our results suggest it is feasible to monitor vital signs continuously on general wards, although acceptability of the device among nurses needs further improvement.
Collapse
Affiliation(s)
- Jobbe P L Leenen
- Department of Surgery, Isala, Zwolle, The Netherlands
- Connected Care Center, Isala, Zwolle, The Netherlands
| | | | | | | | - Cor Kalkman
- Anesthesiology, UMC Utrecht, Utrecht, The Netherlands
| | - Lisette Schoonhoven
- Julius Center for Health Sciences and Primary Care, UMC Utrecht, Utrecht, The Netherlands
- Faculty of Health Sciences, University of Southampton, Southampton, UK
| | | |
Collapse
|
21
|
van Rossum M, Leenen J, Kingma F, Breteler M, van Hillegersberg R, Ruurda J, Kouwenhoven E, van Det M, Luyer M, Nieuwenhuijzen G, Kalkman C, Hermens H. Expectations of Continuous Vital Signs Monitoring for Recognizing Complications After Esophagectomy: Interview Study Among Nurses and Surgeons. JMIR Perioper Med 2021; 4:e22387. [PMID: 33576743 PMCID: PMC7910120 DOI: 10.2196/22387] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 12/18/2020] [Accepted: 01/16/2021] [Indexed: 01/12/2023] Open
Abstract
Background Patients undergoing esophagectomy are at serious risk of developing postoperative complications. To support early recognition of clinical deterioration, wireless sensor technologies that enable continuous vital signs monitoring in a ward setting are emerging. Objective This study explored nurses’ and surgeons’ expectations of the potential effectiveness and impact of continuous wireless vital signs monitoring in patients admitted to the ward after esophagectomy. Methods Semistructured interviews were conducted at 3 esophageal cancer centers in the Netherlands. In each center, 2 nurses and 2 surgeons were interviewed regarding their expectations of continuous vital signs monitoring for early recognition of complications after esophagectomy. Historical data of patient characteristics and clinical outcomes were collected in each center and presented to the local participants to support estimations on clinical outcome. Results The majority of nurses and surgeons expected that continuous vital signs monitoring could contribute to the earlier recognition of deterioration and result in earlier treatment for postoperative complications, although the effective time gain would depend on patient and situational factors. Their expectations regarding the impact of potential earlier diagnosis on clinical outcomes varied. Nevertheless, most caregivers would consider implementing continuous monitoring in the surgical ward to support patient monitoring after esophagectomy. Conclusions Caregivers expected that wireless vital signs monitoring would provide opportunities for early detection of postoperative complications in patients undergoing esophagectomy admitted to the ward and prevent sequelae under certain circumstances. As the technology matures, clinical outcome studies will be necessary to objectify these expectations and further investigate overall effects on patient outcome.
Collapse
Affiliation(s)
- Mathilde van Rossum
- Department of Cardiovascular and Respiratory Physiology, University of Twente, Enschede, Netherlands.,Department of Biomedical Signals and Systems, University of Twente, Enschede, Netherlands.,Department of Anesthesiology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Jobbe Leenen
- Department of Surgery, Isala, Zwolle, Netherlands.,Connected Care Centre, Isala, Zwolle, Netherlands
| | - Feike Kingma
- Department of Surgery, University Medical Center Utrecht, Utrecht, Netherlands
| | - Martine Breteler
- Department of Anesthesiology, University Medical Center Utrecht, Utrecht, Netherlands
| | | | - Jelle Ruurda
- Department of Surgery, University Medical Center Utrecht, Utrecht, Netherlands
| | | | - Marc van Det
- Department of Surgery, ZGT Hospital, Almelo, Netherlands
| | - Misha Luyer
- Department of Surgery, Catharina Hospital, Eindhoven, Netherlands
| | | | - Cor Kalkman
- Department of Anesthesiology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Hermie Hermens
- Department of Biomedical Signals and Systems, University of Twente, Enschede, Netherlands
| |
Collapse
|
22
|
Adaptive threshold-based alarm strategies for continuous vital signs monitoring. J Clin Monit Comput 2021; 36:407-417. [PMID: 33575922 PMCID: PMC9123069 DOI: 10.1007/s10877-021-00666-4] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Accepted: 01/27/2021] [Indexed: 12/20/2022]
Abstract
Continuous vital signs monitoring in post-surgical ward patients may support early detection of clinical deterioration, but novel alarm approaches are required to ensure timely notification of abnormalities and prevent alarm-fatigue. The current study explored the performance of classical and various adaptive threshold-based alarm strategies to warn for vital sign abnormalities observed during development of an adverse event. A classical threshold-based alarm strategy used for continuous vital signs monitoring in surgical ward patients was evaluated retrospectively. Next, (combinations of) six methods to adapt alarm thresholds to personal or situational factors were simulated in the same dataset. Alarm performance was assessed using the overall alarm rate and sensitivity to detect adverse events. Using a wireless patch-based monitoring system, 3999 h of vital signs data was obtained in 39 patients. The clinically used classical alarm system produced 0.49 alarms/patient/day, and alarms were generated for 11 out of 18 observed adverse events. Each of the tested adaptive strategies either increased sensitivity to detect adverse events or reduced overall alarm rate. Combining specific strategies improved overall performance most and resulted in earlier presentation of alarms in case of adverse events. Strategies that adapt vital sign alarm thresholds to personal or situational factors may improve early detection of adverse events or reduce alarm rates as compared to classical alarm strategies. Accordingly, further investigation of the potential of adaptive alarms for continuous vital signs monitoring in ward patients is warranted.
Collapse
|
23
|
Murali S, Brugger N, Rincon F, Mashru M, Cook S, Goy JJ. Cardiac Ambulatory Monitoring: New Wireless Device Validated Against Conventional Holter Monitoring in a Case Series. Front Cardiovasc Med 2020; 7:587945. [PMID: 33330650 PMCID: PMC7733961 DOI: 10.3389/fcvm.2020.587945] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Accepted: 10/30/2020] [Indexed: 12/14/2022] Open
Abstract
Background: Cardiac arrhythmias are very common but underdiagnosed due to their transient and asymptomatic nature. An optimization of arrhythmia detection would permit to better treat patients and could substantially reduce morbidity and mortality. The SmartCardia ScaAI wireless patch is a novel CE IIa approved, single-lead electrocardiographic (ECG) ambulatory monitor designed for cardiac arrhythmias detection. Hypothesis: The accuracy of the new SmartCardia wireless patch to detect arrhythmias is comparable to the conventional Holter monitoring. Methods: Patients referred for a suspicion of arrhythmia between February and March 2020 were included in the trial. Simultaneous ambulatory ECG were recorded using a conventional 24-h Holter and the SmartCardia. The primary endpoint was the detection of cardiac arrhythmias over the total wear time of the devices, defined as premature atrial contraction (PAC), supraventricular tachycardia ≥3 beats, premature ventricular contraction (PVC), and ventricular tachycardia ≥3 beats. Conduction abnormalities, pause ≥2 s and atrioventricular block (AVB), were also tracked. McNemar's test was used to compare the matched pairs of data from both devices. Results: A total of 40 patients were included in the trial. Over the total wear time, there was no significant difference between the devices for ventricular and supraventricular arrhythmias detection. Pauses and AVB were equally identified by the two devices in three patients. Conclusion: Over the total wear time, the SmartCardia device showed an accuracy to detect arrhythmia similar to the 24-h Holter monitoring: single-lead, adhesive-patch monitoring might become an interesting alternative to the conventional Holter monitoring.
Collapse
Affiliation(s)
- Srinivasan Murali
- École polytechnique fédérale de Lausanne Innovation Park, Lausanne, Switzerland
| | | | - Francisco Rincon
- École polytechnique fédérale de Lausanne Innovation Park, Lausanne, Switzerland
| | - Manoj Mashru
- Sir Harkisandas Narottamdas Reliance Hospital, Mumbai, India
| | | | | |
Collapse
|
24
|
Digital Phenotyping and Patient-Generated Health Data for Outcome Measurement in Surgical Care: A Scoping Review. J Pers Med 2020; 10:jpm10040282. [PMID: 33333915 PMCID: PMC7765378 DOI: 10.3390/jpm10040282] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 12/08/2020] [Accepted: 12/11/2020] [Indexed: 12/13/2022] Open
Abstract
Digital phenotyping-the moment-by-moment quantification of human phenotypes in situ using data related to activity, behavior, and communications, from personal digital devices, such as smart phones and wearables-has been gaining interest. Personalized health information captured within free-living settings using such technologies may better enable the application of patient-generated health data (PGHD) to provide patient-centered care. The primary objective of this scoping review is to characterize the application of digital phenotyping and digitally captured active and passive PGHD for outcome measurement in surgical care. Secondarily, we synthesize the body of evidence to define specific areas for further work. We performed a systematic search of four bibliographic databases using terms related to "digital phenotyping and PGHD," "outcome measurement," and "surgical care" with no date limits. We registered the study (Open Science Framework), followed strict inclusion/exclusion criteria, performed screening, extraction, and synthesis of results in line with the PRISMA Extension for Scoping Reviews. A total of 224 studies were included. Published studies have accelerated in the last 5 years, originating in 29 countries (mostly from the USA, n = 74, 33%), featuring original prospective work (n = 149, 66%). Studies spanned 14 specialties, most commonly orthopedic surgery (n = 129, 58%), and had a postoperative focus (n = 210, 94%). Most of the work involved research-grade wearables (n = 130, 58%), prioritizing the capture of activity (n = 165, 74%) and biometric data (n = 100, 45%), with a view to providing a tracking/monitoring function (n = 115, 51%) for the management of surgical patients. Opportunities exist for further work across surgical specialties involving smartphones, communications data, comparison with patient-reported outcome measures (PROMs), applications focusing on prediction of outcomes, monitoring, risk profiling, shared decision making, and surgical optimization. The rapidly evolving state of the art in digital phenotyping and capture of PGHD offers exciting prospects for outcome measurement in surgical care pending further work and consideration related to clinical care, technology, and implementation.
Collapse
|
25
|
The Impact of the COVID-19 Pandemic on Genitourinary Cancer Care: Re-envisioning the Future. Eur Urol 2020; 78:731-742. [PMID: 32893062 PMCID: PMC7471715 DOI: 10.1016/j.eururo.2020.08.030] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Accepted: 08/20/2020] [Indexed: 12/14/2022]
Abstract
CONTEXT The coronavirus disease 2019 (COVID-19) pandemic necessitated rapid changes in medical practice. Many of these changes may add value to care, creating opportunities going forward. OBJECTIVE To provide an evidence-informed, expert-derived review of genitourinary cancer care moving forward following the initial COVID-19 pandemic. EVIDENCE ACQUISITION A collaborative narrative review was conducted using literature published through May 2020 (PubMed), which comprised three main topics: reduced in-person interactions arguing for increasing virtual and image-based care, optimisation of the delivery of care, and the effect of COVID-19 in health care facilities on decision-making by patients and their families. EVIDENCE SYNTHESIS Patterns of care will evolve following the COVID-19 pandemic. Telemedicine, virtual care, and telemonitoring will increase and could offer broader access to multidisciplinary expertise without increasing costs. Comprehensive and integrative telehealth solutions will be necessary, and should consider patients' mental health and access differences due to socioeconomic status. Investigations and treatments will need to maximise efficiency and minimise health care interactions. Solutions such as one stop clinics, day case surgery, hypofractionated radiotherapy, and oral or less frequent drug dosing will be preferred. The pandemic necessitated a triage of those patients whose treatment should be expedited, delayed, or avoided, and may persist with severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) in circulation. Patients whose demographic characteristics are at the highest risk of complications from COVID-19 may re-evaluate the benefit of intervention for less aggressive cancers. Clinical research will need to accommodate virtual care and trial participation. Research dissemination and medical education will increasingly utilise virtual platforms, limiting in-person professional engagement; ensure data dissemination; and aim to enhance patient engagement. CONCLUSIONS The COVID-19 pandemic will have lasting effects on the delivery of health care. These changes offer opportunities to improve access, delivery, and the value of care for patients with genitourinary cancers but raise concerns that physicians and health administrators must consider in order to ensure equitable access to care. PATIENT SUMMARY The coronavirus disease 2019 (COVID-19) pandemic has dramatically changed the care provided to many patients with genitourinary cancers. This has necessitated a transition to telemedicine, changes in threshold or delays in many treatments, and an opportunity to reimagine patient care to maintain safety and improve value moving forward.
Collapse
|
26
|
Murali S, Rincon F, Cassina T, Cook S, Goy JJ. Heart Rate and Oxygen Saturation Monitoring With a New Wearable Wireless Device in the Intensive Care Unit: Pilot Comparison Trial. JMIR BIOMEDICAL ENGINEERING 2020. [DOI: 10.2196/18158] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
Background
Continuous cardiac monitoring with wireless sensors is an attractive option for early detection of arrhythmia and conduction disturbances and the prevention of adverse events leading to patient deterioration. We present a new sensor design (SmartCardia), a wearable wireless biosensor patch, for continuous cardiac and oxygen saturation (SpO2) monitoring.
Objective
This study aimed to test the clinical value of a new wireless sensor device (SmartCardia) and its usefulness in monitoring the heart rate (HR) and SpO2 of patients.
Methods
We performed an observational study and monitored the HR and SpO2 of patients admitted to the intensive care unit (ICU). We compared the device under test (SmartCardia) with the ICU-grade monitoring system (Dräger-Healthcare). We defined optimal correlation between the gold standard and the wireless system as <10% difference for HR and <4% difference for SpO2. Data loss and discrepancy between the two systems were critically analyzed.
Results
A total of 58 ICU patients (42 men and 16 women), with a mean age of 71 years (SD 11), were included in this study. A total of 13.49 (SD 5.53) hours per patient were recorded. This represents a total recorded period of 782.3 hours. The mean difference between the HR detected by the SmartCardia patch and the ICU monitor was 5.87 (SD 16.01) beats per minute (bias=–5.66, SD 16.09). For SpO2, the average difference was 3.54% (SD 3.86; bias=2.9, SD 4.36) for interpretable values. SmartCardia’s patch measures SpO2 only under low-to-no activity conditions and otherwise does not report a value. Data loss and noninterpretable values of SpO2 represented 26% (SD 24) of total measurements.
Conclusions
The SmartCardia device demonstrated clinically acceptable accuracy for HR and SpO2 monitoring in ICU patients.
Collapse
|