1
|
Abuouf Y, AlBadawi M, Ookawara S, Ahmed M. Effect of guidewire insertion in fractional flow reserve procedure for real geometry using computational fluid dynamics. Biomed Eng Online 2021; 20:95. [PMID: 34583689 PMCID: PMC8479905 DOI: 10.1186/s12938-021-00935-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Accepted: 09/15/2021] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND Coronary artery disease is an abnormal contraction of the heart supply blood vessel. It limits the oxygenated blood flow to the heart. Thus, diagnosing its severity helps physicians to select the appropriate treatment plan. Fractional flow reserve (FFR) is the most accurate method to pinpoint the stenosis severity. However, inserting the guidewire across stenosis may cause a false overestimation of severity. METHODS To estimate the errors due to guidewire insertion, reconstructed three-dimensional coronary artery geometry from a patient-specific scan is used. A comprehensive three-dimensional blood flow model is developed. Blood is considered non-Newtonian and the flow is pulsatile. The model is numerically simulated using realistic boundary conditions. RESULTS The FFR value is calculated and compared with the actual flow ratio. Additionally, the ratio between pressure drop and distal dynamic pressure (CDP) is studied. The obtained results for each case are compared and analyzed with the case without a guidewire. It was found that placing the guidewire leads to overestimating the severity of moderate stenosis. It reduces the FFR value from 0.43 to 0.33 with a 23.26% error compared to 0.44 actual flow ratio and the CDP increases from 5.31 to 7.2 with a 35.6% error. FFR value in mild stenosis does not have a significant change due to placing the guidewire. The FFR value decreases from 0.83 to 0.82 compared to the 0.83 actual flow ratio. CONCLUSION Consequently, physicians should consider these errors while deciding the treatment plan.
Collapse
Affiliation(s)
- Yasser Abuouf
- Department of Energy Resources Engineering, Egypt-Japan University of Science and Technology (E-JUST), Postal Code 21934, New Borg El-Arab City, P.O. Box 179, Alexandria, Egypt. .,Mechanical Engineering Department, Faculty of Engineering, Alexandria University, Alexandria, Egypt.
| | - Muhamed AlBadawi
- Department of Energy Resources Engineering, Egypt-Japan University of Science and Technology (E-JUST), Postal Code 21934, New Borg El-Arab City, P.O. Box 179, Alexandria, Egypt.,Engineering Mathematics and Physics Department, Faculty of Engineering, Alexandria University, Alexandria, Egypt
| | - Shinichi Ookawara
- Department of Chemical Engineering, Graduate School of Science and Engineering, Tokyo Institute of Technology, O-okayama, Meguro-ku, Tokyo, 152-8552, Japan
| | - Mahmoud Ahmed
- Department of Energy Resources Engineering, Egypt-Japan University of Science and Technology (E-JUST), Postal Code 21934, New Borg El-Arab City, P.O. Box 179, Alexandria, Egypt.,Mechanical Engineering Department, Assiut University, Assiut, 71516, Egypt
| |
Collapse
|
2
|
Banerjee RK, Ramadurai S, Manegaonkar SM, Rao MB, Rakkimuthu S, Effat MA. Comparison Between 5- and 1-Year Outcomes Using Cutoff Values of Pressure Drop Coefficient and Fractional Flow Reserve for Diagnosing Coronary Artery Diseases. Front Physiol 2021; 12:689517. [PMID: 34335296 PMCID: PMC8317064 DOI: 10.3389/fphys.2021.689517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Accepted: 05/28/2021] [Indexed: 12/02/2022] Open
Abstract
Background The current pressure-based coronary diagnostic index, fractional flow reserve (FFR), has a limited efficacy in the presence of microvascular disease (MVD). To overcome the limitations of FFR, the objective is to assess the recently introduced pressure drop coefficient (CDP), a fundamental fluid dynamics-based combined pressure–flow index. Methods We hypothesize that CDP will result in improved clinical outcomes in comparison to FFR. To test the hypothesis, chi-square test was performed to compare the percent major adverse cardiac events (%MACE) at 5 years between (a) FFR < 0.75 and CDP > 27.9 and (b) FFR < 0.80 and CDP > 25.4 groups using a prospective cohort study. Furthermore, Kaplan–Meier survival curves were compared between the FFR and CDP groups. The results were considered statistically significant for p < 0.05. The outcomes of the CDP arm were presumptive as clinical decision was solely based on the FFR. Results For the complete patient group, the %MACE in the CDP > 27.9 group (10 out of 35, 29%) was lower in comparison to the FFR < 0.75 group (11 out of 20, 55%), and the difference was near significant (p = 0.05). The survival analysis showed a significantly higher survival rate (p = 0.01) in the CDP > 27.9 group (n = 35) when compared to the FFR < 0.75 group (n = 20). The results remained similar for the FFR = 0.80 cutoff. The comparison of the 5-year MACE outcomes with the 1-year outcomes for the complete patient group showed similar trends, with a higher statistical significance for a longer follow-up period of 5 years. Conclusion Based on the MACE and survival analysis outcomes, CDP could possibly be an alternate diagnostic index for decision-making in the cardiac catheterization laboratory. Clinical Trial Registration www.ClinicalTrials.gov, identifier NCT01719016.
Collapse
Affiliation(s)
- Rupak K Banerjee
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH, United States.,Research Services, Veteran Affairs Medical Services, Cincinnati, OH, United States
| | - Sruthi Ramadurai
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH, United States
| | - Shreyash M Manegaonkar
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH, United States
| | - Marepalli B Rao
- Department of Environmental and Public Health Sciences, University of Cincinnati, Cincinnati, OH, United States
| | - Sathyaprabha Rakkimuthu
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH, United States
| | - Mohamed A Effat
- Department of Cardiology, University of Cincinnati Medical Center, Cincinnati, OH, United States
| |
Collapse
|
3
|
Lu Q, Lin W, Zhang R, Chen R, Wei X, Li T, Du Z, Xie Z, Yu Z, Xie X, Liu H. Validation and Diagnostic Performance of a CFD-Based Non-invasive Method for the Diagnosis of Aortic Coarctation. Front Neuroinform 2020; 14:613666. [PMID: 33362500 PMCID: PMC7756015 DOI: 10.3389/fninf.2020.613666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Accepted: 11/13/2020] [Indexed: 11/30/2022] Open
Abstract
Purpose: The clinical diagnosis of aorta coarctation (CoA) constitutes a challenge, which is usually tackled by applying the peak systolic pressure gradient (PSPG) method. Recent advances in computational fluid dynamics (CFD) have suggested that multi-detector computed tomography angiography (MDCTA)-based CFD can serve as a non-invasive PSPG measurement. The aim of this study was to validate a new CFD method that does not require any medical examination data other than MDCTA images for the diagnosis of CoA. Materials and methods: Our study included 65 pediatric patients (38 with CoA, and 27 without CoA). All patients underwent cardiac catheterization to confirm if they were suffering from CoA or any other congenital heart disease (CHD). A series of boundary conditions were specified and the simulated results were combined to obtain a stenosis pressure-flow curve. Subsequently, we built a prediction model and evaluated its predictive performance by considering the AUC of the ROC by 5-fold cross-validation. Results: The proposed MDCTA-based CFD method exhibited a good predictive performance in both the training and test sets (average AUC: 0.948 vs. 0.958; average accuracies: 0.881 vs. 0.877). It also had a higher predictive accuracy compared with the non-invasive criteria presented in the European Society of Cardiology (ESC) guidelines (average accuracies: 0.877 vs. 0.539). Conclusion: The new non-invasive CFD-based method presented in this work is a promising approach for the accurate diagnosis of CoA, and will likely benefit clinical decision-making.
Collapse
Affiliation(s)
- Qiyang Lu
- College of Automation Science and Technology, South China University of Technology, Guangzhou, China.,Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Weiyuan Lin
- College of Automation Science and Technology, South China University of Technology, Guangzhou, China.,Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Ruichen Zhang
- Department of Information Engineering, Northwestern Polytechnical University, Xi'an, China
| | - Rui Chen
- Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Xiaoyu Wei
- Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Tingyu Li
- Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.,Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Zhicheng Du
- Guangdong Key Laboratory of Medicine, Department of Medical Statistics and Epidemiology, Health Information Research Center, School of Public Health, Sun Yat-sen University, Guangzhou, China
| | - Zhaofeng Xie
- Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Zhuliang Yu
- College of Automation Science and Technology, South China University of Technology, Guangzhou, China.,School of Medicine, South China University of Technology, Guangzhou, China
| | - Xinzhou Xie
- Department of Information Engineering, Northwestern Polytechnical University, Xi'an, China
| | - Hui Liu
- Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.,School of Medicine, South China University of Technology, Guangzhou, China
| |
Collapse
|
4
|
Sharma N, Sastry S, Sankovic JM, Kadambi JR, Banerjee RK. Influence of near-wall PIV data on recirculation hemodynamics in a patient-specific moderate stenosis: Experimental-numerical comparison. Biorheology 2020; 57:53-76. [PMID: 33185583 DOI: 10.3233/bir-201001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Recirculation zones within the blood vessels are known to influence the initiation and progression of atherosclerotic lesions. Quantification of recirculation parameters with accuracy remains subjective due to uncertainties in measurement of velocity and derived wall shear stress (WSS). OBJECTIVE The primary aim is to determine recirculation height and length from PIV experiments while validating with two different numerical methods: finite-element (FE) and -volume (FV). Secondary aim is to analyze how FE and FV compare within themselves. METHODS PIV measurements were performed to obtain velocity profiles at eight cross sections downstream of stenosis at flow rate of 200 ml/min. WSS was obtained by linear/quadratic interpolation of experimental velocity measurements close to wall. RESULTS Recirculation length obtained from PIV technique was 1.47 cm and was within 2.2% of previously reported in-vitro measurements. Derived recirculation length from PIV agreed within 6.8% and 8.2% of the FE and FV calculations, respectively. For lower shear rate, linear interpolation with five data points results in least error. For higher shear rate either higher order (quadratic) interpolation with five data points or lower order (linear) with lesser (three) data points leads to better results. CONCLUSION Accuracy of the recirculation parameters is dependent on number of near wall PIV data points and the type of interpolation algorithm used.
Collapse
Affiliation(s)
- Neha Sharma
- Department of Aerospace Engineering, University of Cincinnati, Cincinnati, OH, USA
| | - Sudeep Sastry
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH, USA
| | | | - Jaikrishnan R Kadambi
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Rupak K Banerjee
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
5
|
D'Souza GA, Taylor MD, Banerjee RK. Methodology for Hemodynamic Assessment of a Three-Dimensional Printed Patient-Specific Vascular Test Device. J Med Device 2019. [DOI: 10.1115/1.4043992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Assessing hemodynamics in vasculature is important for the development of cardiovascular diagnostic parameters and evaluation of medical devices. Benchtop experiments are a safe and comprehensive preclinical method for testing new diagnostic endpoints and devices within a controlled environment. Recent advances in three-dimensional (3D) printing have enhanced benchtop tests by allowing generation of patient-specific and pathophysiologic conditions. We used 3D printing, coupled with image processing and computer-aided design (CAD), to develop a patient-specific vascular test device from clinical data. The proximal pulmonary artery (PA) tree including the main, left, and right pulmonary arteries, with a stenosis within the left PA was selected as a representative anatomy for developing the vascular test device. Three test devices representing clinically relevant stenosis severities, 90%, 80%, and 70% area stenosis, were evaluated at different cardiac outputs (COs). A mock circulatory loop (MCL) generating pathophysiologic pulmonary pressure and flow was used to evaluate the hemodynamics within the devices. The dimensionless pressure drop–velocity ratio characteristic curves for the three stenosis severities were obtained. At a fixed CO, the dimensionless pressure drop increased nonlinearly with an increase in (a) the velocity ratio for a fixed stenosis severity and (b) the stenosis severity at a specific velocity ratio. The dimensionless pressure drop observed in vivo was similar (within 1%) to that measured in moderate area stenosis of 70% because both flows were viscous dominated. The hemodynamics of the 3D printed test device can be used for evaluating diagnostic endpoints and medical devices in a preclinical setting under realistic conditions.
Collapse
Affiliation(s)
- Gavin A. D'Souza
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH 45221
| | - Michael D. Taylor
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH 45229
| | - Rupak K. Banerjee
- Department of Mechanical and Materials Engineering, University of Cincinnati, 593 Rhodes Hall, Cincinnati, OH 45221 e-mail:
| |
Collapse
|
6
|
D'Souza GA, Banerjee RK, Taylor MD. Evaluation of pulmonary artery stenosis in congenital heart disease patients using functional diagnostic parameters: An in vitro study. J Biomech 2018; 81:58-67. [PMID: 30293825 DOI: 10.1016/j.jbiomech.2018.09.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Revised: 07/23/2018] [Accepted: 09/13/2018] [Indexed: 02/03/2023]
Abstract
Congenital pulmonary artery (PA) stenosis is often associated with abnormal PA hemodynamics including increased pressure drop (Δp) and reduced asymmetric flow (Q), which may result in right ventricular dysfunction. We propose functional diagnostic parameters, pressure drop coefficient (CDP), energy loss (Eloss), and normalized energy loss (E¯loss) to characterize pulmonary hemodynamics, and evaluate their efficacy in delineating stenosis severity using in vitro experiments. Subject-specific test sections including the main PA (MPA) bifurcating into left and right PAs (LPA, RPA) with a discrete LPA stenosis were manufactured from cross-sectional imaging and 3D printing. Three clinically-relevant stenosis severities, 90% area stenosis (AS), 80% AS, and 70% AS, were evaluated at different cardiac outputs (COs). A benchtop flow loop simulating pulmonary hemodynamics was used to measure Q and Δp within the test sections. The experimental Δp-Q characteristics along with clinical data were used to obtain pathophysiologic conditions and compute the diagnostic parameters. The pathophysiologic QLPA decreased as the stenosis severity increased at a fixed CO. CDPLPA, Eloss,LPA (absolute), and E¯loss,LPA (absolute) increased with an increase in LPA stenosis severity at a fixed CO. Importantly, CDPLPA and E¯loss,LPA had reduced variability with CO, and distinct values for each LPA stenosis severity. Under variable CO, a) CDPLPA values were 14.5-21.0 (70% AS), 60.7- 2.2 (80% AS), ≥ 261.6 (90% AS), and b) E¯loss,LPA values (in mJ per QLPA) were -501.9 to -1023.8 (70% AS), -1247.6 to -1773.0 (80% AS), -1934.5 (90% AS). Hence, CDPLPA and E¯loss,LPA are expected to assess the true functional severity of PA stenosis.
Collapse
Affiliation(s)
- Gavin A D'Souza
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH, USA
| | - Rupak K Banerjee
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH, USA.
| | - Michael D Taylor
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA.
| |
Collapse
|
7
|
Peelukhana SV, Banerjee RK, van de Hoef TP, Kolli KK, Effat M, Helmy T, Leesar M, Kerr H, Piek JJ, Succop P, Back L, Arif I. Evaluation of lesion flow coefficient for the detection of coronary artery disease in patient groups from two academic medical centers. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2018; 19:348-354. [DOI: 10.1016/j.carrev.2017.08.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2017] [Accepted: 08/30/2017] [Indexed: 01/09/2023]
|
8
|
Xie X, Zheng M, Wen D, Li Y, Xie S. A new CFD based non-invasive method for functional diagnosis of coronary stenosis. Biomed Eng Online 2018; 17:36. [PMID: 29566702 PMCID: PMC5863834 DOI: 10.1186/s12938-018-0468-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Accepted: 03/17/2018] [Indexed: 02/07/2023] Open
Abstract
Background Accurate functional diagnosis of coronary stenosis is vital for decision making in coronary revascularization. With recent advances in computational fluid dynamics (CFD), fractional flow reserve (FFR) can be derived non-invasively from coronary computed tomography angiography images (FFRCT) for functional measurement of stenosis. However, the accuracy of FFRCT is limited due to the approximate modeling approach of maximal hyperemia conditions. To overcome this problem, a new CFD based non-invasive method is proposed. Methods Instead of modeling maximal hyperemia condition, a series of boundary conditions are specified and those simulated results are combined to provide a pressure-flow curve for a stenosis. Then, functional diagnosis of stenosis is assessed based on parameters derived from the obtained pressure-flow curve. Results The proposed method is applied to both idealized and patient-specific models, and validated with invasive FFR in six patients. Results show that additional hemodynamic information about the flow resistances of a stenosis is provided, which cannot be directly obtained from anatomy information. Parameters derived from the simulated pressure-flow curve show a linear and significant correlations with invasive FFR (r > 0.95, P < 0.05). Conclusion The proposed method can assess flow resistances by the pressure-flow curve derived parameters without modeling of maximal hyperemia condition, which is a new promising approach for non-invasive functional assessment of coronary stenosis.
Collapse
Affiliation(s)
- Xinzhou Xie
- Department of Electronic Science and Technology, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, Shaanxi, People's Republic of China.
| | - Minwen Zheng
- Department of Radiology, Xijing Hospital, Fourth Military Medical University, 15 West Changle Road, Xi'an, Shaanxi, People's Republic of China
| | - Didi Wen
- Department of Radiology, Xijing Hospital, Fourth Military Medical University, 15 West Changle Road, Xi'an, Shaanxi, People's Republic of China
| | - Yabing Li
- Department of Electronic Science and Technology, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, Shaanxi, People's Republic of China
| | - Songyun Xie
- Department of Electronic Science and Technology, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, Shaanxi, People's Republic of China
| |
Collapse
|
9
|
GOVINDARAJU KALIMUTHU, VISWANATHAN GIRISHN, BADRUDDIN IRFANANJUM, WELDEMARIAM SIRAKAREGAWI, GEBREHIWOT WOLDUZINA, KAMANGAR SARFARAZ. THE MECHANICAL FACTORS INFLUENCING THE ASSESSMENT OF INTERMEDIATE STENOSIS SEVERITY EXPLAINED THROUGH FRACTIONAL FLOW RESERVE. J MECH MED BIOL 2017. [DOI: 10.1142/s0219519417300010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Assessment of intermediate coronary lesions with diameter stenosis of 40% to 70% severity is being a challenge for cardiologist to identify potentially ischemic stenosis for revascularization and nonculprit stenosis which can be deferred from stenting. An invasive coronary angiography and intravascular ultrasound provide anatomic information of stenosis severity whereas an invasive fractional flow reserve index (FFR) provides the functional significance of the stenosis severity. The measurement of functional significance of stenosis severity minimizes the procedural complications such as coronary dissection, in stent restenosis etc. rather than anatomical significance measure. The FFR cutoff value of [Formula: see text]0.8 is used to distinguish ischemic and nonischemic stenosis. The FFR is clinically well validated even though it is influenced by the mechanical factors such as hyperemic flow and guide wire insertion. In recent times, noninvasive coronary computed tomography (CCTA) modality has become popular in the diagnosis of coronary artery disease. The CCTA permits the assessment of cross-sectional parameters such as minimum lumen area and lumen diameter, lesion length and plaque morphology. However, the CCTA provides limited information on the functional significance of stenotic lesions as compared to FFR. The purpose of this review is to discuss the mechanical factors influencing the invasive FFR while assessing the functional significance of intermediate stenosis severity. In addition, the hidden mechanical factors influencing the noninvasive CCTA assessment of stenosis severity will be discussed from the critical information obtained from FFR which could be beneficial for the clinician particularly in the assessment of intermediate stenosis severity.
Collapse
Affiliation(s)
- KALIMUTHU GOVINDARAJU
- Ethiopian Institute of Technology, School of Mechanical and Industrial Engineering, Mekelle University, Mekelle, Ethiopia
| | | | | | - SIRAK AREGAWI WELDEMARIAM
- Ethiopian Institute of Technology, School of Mechanical and Industrial Engineering, Mekelle University, Mekelle, Ethiopia
| | - WOLDU ZINA GEBREHIWOT
- Ethiopian Institute of Technology, School of Mechanical and Industrial Engineering, Mekelle University, Mekelle, Ethiopia
| | - SARFARAZ KAMANGAR
- Department of Mechanical Engineering, University of Malaya, Malaysia
| |
Collapse
|
10
|
Govindaraju K, Viswanathan GN, Badruddin IA, Kamangar S, Salman Ahmed NJ, Al-Rashed AAAA. The influence of artery wall curvature on the anatomical assessment of stenosis severity derived from fractional flow reserve: a computational fluid dynamics study. Comput Methods Biomech Biomed Engin 2016; 19:1541-9. [PMID: 27052093 DOI: 10.1080/10255842.2016.1170119] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
This study aims to investigate the influence of artery wall curvature on the anatomical assessment of stenosis severity and to identify a region of misinterpretation in the assessment of per cent area stenosis (AS) for functionally significant stenosis using fractional flow reserve (FFR) as standard. Five artery models of different per cent AS severity (70, 75, 80, 85 and 90%) were considered. For each per cent AS severity, the angle of curvature of the arterial wall varied from straight to an increasingly curved model (0°, 30°, 60°, 90° and 120°). Computational fluid dynamics was performed under transient physiologic hyperemic flow conditions to investigate the influence of artery wall curvature on the pressure drop and the FFR. The findings in this study may be useful in in vitro anatomical assessment of functionally significant stenosis. The FFR decreased with increasing stenosis severity for a given curvature of the artery wall. Moreover, a significant decrease in FFR was found between straight and curved models discussed for a given severity condition. These findings indicate that the curvature effect was included in the FFR assessment in contrast to minimum lumen area (MLA) or per cent AS assessment. The MLA or per cent AS assessment may lead to underestimation of stenosis severity. From this numerical study, an uncertainty region could be evaluated using the clinical FFR cutoff value of 0.8. This value was observed at 81.98 and 79.10% AS for arteries with curvature angles of 0° and 120° respectively. In conclusion, the curvature of the artery should not be neglected in in vitro anatomical assessment.
Collapse
Affiliation(s)
- Kalimuthu Govindaraju
- a Centre for Engineering Programs , HELP College of Arts and Technology , Kuala Lumpur , Malaysia
| | - Girish N Viswanathan
- b Cardiology department , Derriford Hospital , Plymouth , UK.,c Institute of Cellular Medicine , Newcastle University , Newcastle upon Tyne , UK
| | - Irfan Anjum Badruddin
- d Department of Mechanical Engineering , University of Malaya , Kuala Lumpur , Malaysia
| | - Sarfaraz Kamangar
- d Department of Mechanical Engineering , University of Malaya , Kuala Lumpur , Malaysia
| | - N J Salman Ahmed
- e Center for Energy Sciences, Department of Mechanical Engineering , University of Malaya , Kuala Lumpur , Malaysia
| | - Abdullah A A A Al-Rashed
- f Department of Automotive and Marine Engineering Technology , College of Technological Studies, The Public Authority for Applied Education and Training , Kuwait city , Kuwait
| |
Collapse
|
11
|
Effat MA, Peelukhana SV, Banerjee RK. Clinical outcomes of combined flow-pressure drop measurements using newly developed diagnostic endpoint: Pressure drop coefficient in patients with coronary artery dysfunction. World J Cardiol 2016; 8:283-292. [PMID: 27022460 PMCID: PMC4807317 DOI: 10.4330/wjc.v8.i3.283] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Revised: 11/02/2015] [Accepted: 01/04/2016] [Indexed: 02/06/2023] Open
Abstract
AIM: To combine pressure and flow parameter, pressure drop coefficient (CDP) will result in better clinical outcomes in comparison to the fractional flow reserve (FFR) group.
METHODS: To test this hypothesis, a comparison was made between the FFR < 0.75 and CDP > 27.9 groups in this study, for the major adverse cardiac events [major adverse cardiac events (MACE): Primary outcome] and patients’ quality of life (secondary outcome). Further, a comparison was also made between the survival curves for the FFR < 0.75 and CDP > 27.9 groups. Two-tailed χ2 test proportions were performed for the comparison of primary and secondary outcomes. Kaplan-Meier survival analysis was performed to compare the survival curves of FFR < 0.75 and CDP > 27.9 groups (MedcalcV10.2, Mariakerke, Belgium). Results were considered statistically significant for P < 0.05.
RESULTS: The primary outcomes (%MACE) in the FFR < 0.75 group (20%, 4 out of 20) was not statistically different (P = 0.24) from the %MACE occurring in CDP > 27.9 group (8.57%, 2 out of 35). Noteworthy is the reduction in the %MACE in the CDP > 27.9 group, in comparison to the FFR < 0.75 group. Further, the secondary outcomes were not statistically significant between the FFR < 0.75 and CDP > 27.9 groups. Survival analysis results suggest that the survival time for the CDP > 27.9 group (n = 35) is significantly higher (P = 0.048) in comparison to the survival time for the FFR < 0.75 group (n = 20). The results remained similar for a FFR = 0.80 cut-off.
CONCLUSION: Based on the above, CDP could prove to be a better diagnostic end-point for clinical revascularization decision-making in the cardiac catheterization laboratories.
Collapse
|
12
|
Johnson NP, Kirkeeide RL, Gould KL. History and Development of Coronary Flow Reserve and Fractional Flow Reserve for Clinical Applications. Interv Cardiol Clin 2015; 4:397-410. [PMID: 28581927 DOI: 10.1016/j.iccl.2015.06.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
We discuss the historical development of clinical coronary physiology, emphasizing coronary flow reserve (CFR) and fractional flow reserve (FFR). Our analysis focuses on the clinical motivations and technologic advances that prompted and enabled the application of physiology for patient diagnosis. CFR grew from the general concepts of physiologic and coronary reserve, linking the anatomic severity of a lesion to its impact on hyperemic flow. FFR developed from existing models relating pressure measurements to the potential for flow to increase after removing a stenosis. Because pressure measurements have proved easier and more robust than flow measurements, FFR has become the dominant metric.
Collapse
Affiliation(s)
- Nils P Johnson
- Division of Cardiology, Department of Medicine, Weatherhead PET Center for Preventing and Reversing Atherosclerosis, Memorial Hermann Hospital, University of Texas Medical School at Houston, 6431 Fannin Street, Room MSB 4.256, Houston, TX 77030, USA.
| | - Richard L Kirkeeide
- Division of Cardiology, Department of Medicine, Weatherhead PET Center for Preventing and Reversing Atherosclerosis, Memorial Hermann Hospital, University of Texas Medical School at Houston, 6431 Fannin Street, Room MSB 4.256, Houston, TX 77030, USA
| | - K Lance Gould
- Division of Cardiology, Department of Medicine, Weatherhead PET Center for Preventing and Reversing Atherosclerosis, Memorial Hermann Hospital, University of Texas Medical School at Houston, 6431 Fannin Street, Room MSB 4.256, Houston, TX 77030, USA
| |
Collapse
|
13
|
Kolli KK, van de Hoef TP, Effat MA, Banerjee RK, Peelukhana SV, Succop P, Leesar MA, Imran A, Piek JJ, Helmy TA. Diagnostic cutoff for pressure drop coefficient in relation to fractional flow reserve and coronary flow reserve: A patient-level analysis. Catheter Cardiovasc Interv 2015; 87:273-82. [PMID: 26424295 DOI: 10.1002/ccd.26063] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2014] [Revised: 03/31/2015] [Accepted: 05/19/2015] [Indexed: 12/28/2022]
Abstract
OBJECTIVES AND BACKGROUND Functional assessment of intermediate coronary stenosis during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR), coronary flow reserve (CFR), hyperemic stenosis resistance index (HSR), and hyperemic microvascular resistance (HMR). CDP (ratio of pressure drop across a stenosis to distal dynamic pressure), a nondimensional index derived from fundamental fluid dynamic principles, based on a combination of intracoronary pressure, and flow measurements may improve the functional assessment of coronary lesion severity. METHODS Patient-level data pertaining to 350 intracoronary pressure and flow measurements across coronary stenoses was assessed to evaluate CFR, FFR, HSR, HMR, and CDP. CDP was calculated as (ΔP)/(0.5 × ρ × APV(2)). The density of blood (ρ) was assumed to be 1.05 g/cm(3). The correlation of current diagnostic parameters (CFR, FFR, HSR, and HMR) with CDP was evaluated. The receiver operating characteristic (ROC) curve was used to identify the optimal cut-off point of CDP, corresponding to the clinically used cut-off values (FFR = 0.80 and CFR = 2.0). RESULTS CDP correlated significantly with FFR (r = 0.81, P < 0.05) and had significant diagnostic efficiency (ROC-area under curve of 86%), specificity (72%) and sensitivity (85%) at FFR < 0.8. The corresponding cut-off value for CDP to detect FFR < 0.8 was at CDP>25.4. CDP also correlated significantly (r = 0.98, P < 0.05) with epicardial-specific parameter, HSR. CONCLUSIONS CDP, a functional parameter based on both intracoronary pressure and flow measurements, has close agreement (area under ROC curve = 86%) with FFR, the frequently used method of evaluating stenosis severity.
Collapse
Affiliation(s)
- Kranthi K Kolli
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, Ohio.,Veteran Affairs Medical Center, Cincinnati, Ohio
| | - Tim P van de Hoef
- Department of Cardiology, Academic Medical Center, Amsterdam, The Netherlands
| | - Mohamed A Effat
- Veteran Affairs Medical Center, Cincinnati, Ohio.,Division of Cardiovascular Disease, University of Cincinnati, Cincinnati, Ohio
| | - Rupak K Banerjee
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, Ohio.,Veteran Affairs Medical Center, Cincinnati, Ohio
| | - Srikara V Peelukhana
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, Ohio.,Veteran Affairs Medical Center, Cincinnati, Ohio
| | - Paul Succop
- Department of Environmental Health, University of Cincinnati, Cincinnati, Ohio
| | - Massoud A Leesar
- Division of Cardiovascular Disease, University of Alabama-Birmingham, Alabama
| | - Arif Imran
- Veteran Affairs Medical Center, Cincinnati, Ohio.,Division of Cardiovascular Disease, University of Cincinnati, Cincinnati, Ohio
| | - Jan J Piek
- Department of Cardiology, Academic Medical Center, Amsterdam, The Netherlands
| | - Tarek A Helmy
- Division of Cardiology, Saint Louis University School of Medicine, St. Louis, Missouri
| |
Collapse
|
14
|
Rajabi-Jaghargh E, Banerjee RK. Combined functional and anatomical diagnostic endpoints for assessing arteriovenous fistula dysfunction. World J Nephrol 2015; 4:6-18. [PMID: 25664243 PMCID: PMC4317629 DOI: 10.5527/wjn.v4.i1.6] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2014] [Revised: 08/26/2014] [Accepted: 11/19/2014] [Indexed: 02/06/2023] Open
Abstract
Failure of arteriovenous fistulas (AVF) to mature and thrombosis in matured fistulas have been the major causes of morbidity and mortality in hemodialysis patients. Stenosis, which occurs due to adverse remodeling in AVFs, is one of the major underlying factors under both scenarios. Early diagnosis of a stenosis in an AVF can provide an opportunity to intervene in a timely manner for either assisting the maturation process or avoiding the thrombosis. The goal of surveillance strategies was to supplement the clinical evaluation (i.e., physical examination) of the AVF for better and earlier diagnosis of a developing stenosis. Surveillance strategies were mainly based on measurement of functional hemodynamic endpoints, including blood flow (Qa) to the vascular access and venous access pressure (VAP). As the changes in arterial pressure (MAP) affects the level of VAP, the ratio of VAP to MAP (VAPR = VAP/MAP) was used for diagnosis. A Qa < 400-500 mL/min or a VAPR > 0.55 is considered sign of significant stenosis, which requires immediate intervention. However, due to the complex nature of AVFs, the surveillance strategies have failed to consistently detect stenosis under different scenarios. VAPR has been primarily developed to detect outflow stenosis in arteriovenous grafts, and it hasn’t been successful in accurate diagnosis of outflow lesions in AVFs. Similarly, AVFs can maintain relatively high blood flow despite the presence of a significant outflow stenosis and thus, Qa has been found to be a better predictor of only inflow lesions. Similar shortcomings have been reported in the detection of functional severity of coronary stenosis using diagnostic endpoints that were based on either flow or pressure. This limitation has been associated with the fact that both pressure and flow change in the presence of a stenosis and thus, hemodynamic diagnostic endpoints that employ only one of these parameters are inherently prone to inaccuracies. Recent attempts have resulted in development of new diagnostic endpoints that can combine the effects of pressure and flow. These new hemodynamic diagnostic endpoints have shown to be better predictors of functional severity of lesions as compared to either flow or pressure based counterparts. In this review article, we discussed the advantages and limitations of current functional and anatomical diagnostic endpoints in AVFs.
Collapse
|
15
|
Peelukhana SV, Kerr H, Kolli KK, Fernandez-Ulloa M, Gerson M, Effat M, Arif I, Helmy T, Banerjee R. Benefit of cardiac N-13 PET CFR for combined anatomical and functional diagnosis of ischemic coronary artery disease: a pilot study. Ann Nucl Med 2014; 28:746-60. [DOI: 10.1007/s12149-014-0869-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2014] [Accepted: 06/05/2014] [Indexed: 01/26/2023]
|
16
|
Kolli KK, Effat MA, Peelukhana SV, Succop P, Back LH, Leesar MA, Helmy TA, Imran A, Banerjee RK. Hyperemia-free delineation of epicardial and microvascular impairments using a basal index. Ann Biomed Eng 2014; 42:1681-90. [PMID: 24806315 DOI: 10.1007/s10439-014-1020-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2014] [Accepted: 04/26/2014] [Indexed: 01/18/2023]
Abstract
The assessment of functional coronary lesion severity using intracoronary hemodynamic parameters like the pressure-derived fractional flow reserve and the flow-derived coronary flow reserve are known to rely critically on the establishment of maximal hyperemia. We evaluated a hyperemia-free index, basal pressure drop coefficient (bCDP), that combines pressure and velocity for simultaneous assessment of the status of both epicardial and microvascular circulations. In 23 pigs, simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual-sensor tipped guidewire in the settings of both normal and abnormal microcirculation with the presence of epicardial lesions of area stenosis (AS) < 50% and AS > 50%. The bCDP, a parameter based on fundamental fluid dynamics principles, was calculated as the transtenotic pressure-drop divided by the dynamic pressure in the distal vessel, measured under baseline (without hyperemia) conditions. The group mean values of bCDP for normal (84 ± 18) and abnormal (124.5 ± 15.6) microcirculation were significantly different. Similarly, the mean values of bCDP from AS < 50% (72.5 ± 16.1) and AS > 50% (136 ± 17.2) were also significantly different (p < 0.05). The bCDP could significantly distinguish between lesions of AS < 50% to AS > 50% under normal microcirculation (52.1 vs. 85.8; p < 0.05) and abnormal microcirculation (84.9 vs. 172; p < 0.05). Further, the bCDP correlated linearly and significantly with the hyperemic parameters FFR (r = 0.42, p < 0.05) and CDP (r = 0.50, p < 0.05). The bCDP is a promising clinical diagnostic parameter that can independently assess the severity of epicardial stenosis and microvascular impairment. We believe that it has an immediate appeal for detection of coronary artery disease if validated clinically.
Collapse
Affiliation(s)
- Kranthi K Kolli
- Department of Mechanical and Materials Engineering, University of Cincinnati, 598 Rhodes Hall, PO Box 210072, Cincinnati, OH, 45221-0072, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Govindaraju K, Kamangar S, Badruddin IA, Viswanathan GN, Badarudin A, Salman Ahmed N. Effect of porous media of the stenosed artery wall to the coronary physiological diagnostic parameter: A computational fluid dynamic analysis. Atherosclerosis 2014; 233:630-635. [DOI: 10.1016/j.atherosclerosis.2014.01.043] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2013] [Revised: 01/05/2014] [Accepted: 01/20/2014] [Indexed: 11/28/2022]
|
18
|
D’Souza GA, Peelukhana SV, Banerjee RK. Diagnostic Uncertainties During Assessment of Serial Coronary Stenoses: An In Vitro Study. J Biomech Eng 2014; 136:021026. [DOI: 10.1115/1.4026317] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2013] [Accepted: 12/23/2013] [Indexed: 02/02/2023]
Abstract
Currently, the diagnosis of coronary stenosis is primarily based on the well-established functional diagnostic parameter, fractional flow reserve (FFR: ratio of pressures distal and proximal to a stenosis). The threshold of FFR has a “gray” zone of 0.75–0.80, below which further clinical intervention is recommended. An alternate diagnostic parameter, pressure drop coefficient (CDP: ratio of trans-stenotic pressure drop to the proximal dynamic pressure), developed based on fundamental fluid dynamics principles, has been suggested by our group. Additional serial stenosis, present downstream in a single vessel, reduces the hyperemic flow, Q˜h, and pressure drop, Δp˜, across an upstream stenosis. Such hemodynamic variations may alter the values of FFR and CDP of the upstream stenosis. Thus, in the presence of serial stenoses, there is a need to evaluate the possibility of misinterpretation of FFR and test the efficacy of CDP of individual stenoses. In-vitro experiments simulating physiologic conditions, along with human data, were used to evaluate nine combinations of serial stenoses. Different cases of upstream stenosis (mild: 64% area stenosis (AS) or 40% diameter stenosis (DS); intermediate: 80% AS or 55% DS; and severe: 90% AS or 68% DS) were tested under varying degrees of downstream stenosis (mild, intermediate, and severe). The pressure drop-flow rate characteristics of the serial stenoses combinations were evaluated for determining the effect of the downstream stenosis on the upstream stenosis. In general, Q˜h and Δp˜ across the upstream stenosis decreased when the downstream stenosis severity was increased. The FFR of the upstream mild, intermediate, and severe stenosis increased by a maximum of 3%, 13%, and 19%, respectively, when the downstream stenosis severity increased from mild to severe. The FFR of a stand-alone intermediate stenosis under a clinical setting is reported to be ∼0.72. In the presence of a downstream stenosis, the FFR values of the upstream intermediate stenosis were either within (0.77 for 80%–64% AS and 0.79 for 80%–80% AS) or above (0.88 for 80%–90% AS) the “gray” zone (0.75–0.80). This artificial increase in the FFR value within or above the “gray” zone for an upstream intermediate stenosis when in series with a clinically relevant downstream stenosis could lead to misinterpretation of functional stenosis severity. In contrast, a distinct range of CDP values was observed for each case of upstream stenosis (mild: 8–10; intermediate: 47–54; and severe: 130–155). The nonoverlapping range of CDP could better delineate the effect of the downstream stenosis from the upstream stenosis and allow for the accurate diagnosis of the functional severity of the upstream stenosis.
Collapse
Affiliation(s)
- Gavin A. D’Souza
- School of Dynamic Systems, Mechanical Engineering Program, University of Cincinnati, Cincinnati, OH 45221
| | - Srikara V. Peelukhana
- School of Dynamic Systems, Mechanical Engineering Program, University of Cincinnati, Cincinnati, OH 45221
| | - Rupak K. Banerjee
- School of Dynamic Systems, Mechanical Engineering Program, University of Cincinnati, Cincinnati, OH 45221 e-mail:
| |
Collapse
|
19
|
Kolli KK, Helmy TA, Peelukhana SV, Arif I, Leesar MA, Back LH, Banerjee RK, Effat MA. Functional diagnosis of coronary stenoses using pressure drop coefficient: a pilot study in humans. Catheter Cardiovasc Interv 2013; 83:377-85. [PMID: 23785016 DOI: 10.1002/ccd.25085] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2012] [Revised: 04/27/2013] [Accepted: 06/09/2013] [Indexed: 01/10/2023]
Abstract
OBJECTIVES AND BACKGROUND Myocardial fractional flow reserve (FFR) in conjunction with coronary flow reserve (CFR) is used to evaluate the hemodynamic severity of coronary lesions. However, discordant results between FFR and CFR have been observed in intermediate coronary lesions. A functional parameter, pressure drop coefficient (CDP; ratio of pressure drop to distal dynamic pressure), was assessed using intracoronary pressure drop (dp) and average peak velocity (APV). The CDP is a nondimensional ratio, derived from fundamental fluid dynamic principles. We sought to evaluate the correlation of CDP with FFR, CFR, and hyperemic stenosis resistance (HSR: ratio of pressure drop to APV) in human subjects. METHODS Twenty-seven patients with reversible perfusion defects based on SPECT were consented for the study before cardiac catheterization. Distal coronary pressure and APV were measured simultaneously for each coronary lesion using a Combowire(©) during cardiac catheterization. Reference diameter, minimal lumen diameter, and %AS were obtained by quantitative coronary angiography. Maximum hyperemia was induced by IV adenosine (140 µg/kg/min). CDP was calculated as, (Δp)/(0.5 × ρ × APV(2) ). The density of blood (ρ) was assumed to be 1.05 gm/cm(3) . RESULTS The functional index, CDP, when correlated simultaneously with FFR and CFR, was found to have a significant correlation (r = 0.61; P < 0.05). Similarly a significant correlation was achieved when CDP was correlated with HSR (r = 0.91; P < 0.001). This is consistent with the definition of CDP, which is a functional parameter that includes both pressure and flow information. CONCLUSIONS CDP, a nondimensional parameter combining simultaneous measurements of pressure drop and velocity data, can accurately define the severity of coronary stenoses and could prove advantageous clinically.
Collapse
Affiliation(s)
- Kranthi K Kolli
- School of Dynamic Systems, Mechanical Engineering Program, University of Cincinnati, Cincinnati, Ohio; Veteran Affairs Medical Center, Cincinnati, Ohio
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Peelukhana SV, Kolli KK, Leesar MA, Effat MA, Helmy TA, Arif I, Schneeberger EW, Succop P, Banerjee RK. Effect of myocardial contractility on hemodynamic end points under concomitant microvascular disease in a porcine model. Heart Vessels 2013; 29:97-109. [PMID: 23624760 DOI: 10.1007/s00380-013-0355-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2012] [Accepted: 04/12/2013] [Indexed: 12/15/2022]
Abstract
In this study, coronary diagnostic parameters, pressure drop coefficient (CDP: ratio of trans-stenotic pressure drop to distal dynamic pressure), and lesion flow coefficient (LFC: ratio of % area stenosis (%AS) to the CDP at throat region), were evaluated to distinguish levels of %AS under varying contractility conditions, in the presence of microvascular disease (MVD). In 10 pigs, %AS and MVD were created using angioplasty balloons and 90-μm microspheres, respectively. Simultaneous measurements of pressure drop, left ventricular pressure (p), and velocity were obtained. Contractility was calculated as (dp/dt)max, categorized into low contractility <900 mmHg/s and high contractility >900 mmHg/s, and in each group, compared between %AS <50 and >50 using analysis of variance. In the presence of MVD, between the %AS <50 and >50 groups, values of CDP (71 ± 1.4 and 121 ± 1.3) and LFC (0.10 ± 0.04 and 0.19 ± 0.04) were significantly different (P < 0.05), under low-contractility conditions. A similar %AS trend was observed under high-contractility conditions (CDP: 18 ± 1.4 and 91 ± 1.4; LFC: 0.08 ± 0.04 and 0.25 ± 0.04). Under MVD conditions, similar to fractional flow reserve, CDP and LFC were not influenced by contractility.
Collapse
Affiliation(s)
- Srikara Viswanath Peelukhana
- School of Dynamic Systems, Department of Mechanical Engineering, University of Cincinnati, 593 Rhodes Hall, Cincinnati, OH, 45220, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Govindaraju K, Badruddin IA, Viswanathan GN, Ramesh SV, Badarudin A. Evaluation of functional severity of coronary artery disease and fluid dynamics' influence on hemodynamic parameters: A review. Phys Med 2012; 29:225-32. [PMID: 22704601 DOI: 10.1016/j.ejmp.2012.03.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2011] [Revised: 03/19/2012] [Accepted: 03/28/2012] [Indexed: 11/29/2022] Open
Abstract
Coronary Artery Disease (CAD) is responsible for most of the deaths in patients with cardiovascular diseases. Diagnostic coronary angiography analysis offers an anatomical knowledge of the severity of the stenosis. The functional or physiological significance is more valuable than the anatomical significance of CAD. Clinicians assess the functional severity of the stenosis by resorting to an invasive measurement of the pressure drop and flow. Hemodynamic parameters, such as pressure wire assessment fractional flow reserve (FFR) or Doppler wire assessment coronary flow reserve (CFR) are well-proven techniques to evaluate the physiological significance of the coronary artery stenosis in the cardiac catheterization laboratory. Between the two techniques mentioned above, the FFR is seen as a very useful index. The presence of guide wire reduces the coronary flow which causes the underestimation of pressure drop across the stenosis which leads to dilemma for the clinicians in the assessment of moderate stenosis. In such condition, the fundamental fluid mechanics is useful in the development of new functional severity parameters such as pressure drop coefficient and lesion flow coefficient. Since the flow takes place in a narrowed artery, the blood behaves as a non-Newtonian fluid. Computational fluid dynamics (CFD) allows a complete coronary flow simulation to study the relationship between the pressure and flow. This paper aims at explaining (i) diagnostic modalities for the evaluation of the CAD and valuable insights regarding FFR in the evaluation of the functional severity of the CAD (ii) the role of fluid dynamics in measuring the severity of CAD.
Collapse
|
22
|
Peelukhana SV, Banerjee RK, Kolli KK, Effat MA, Helmy TA, Leesar MA, Schneeberger EW, Succop P, Gottliebson W, Irif A. Effect of heart rate on hemodynamic endpoints under concomitant microvascular disease in a porcine model. Am J Physiol Heart Circ Physiol 2012; 302:H1563-73. [PMID: 22287585 DOI: 10.1152/ajpheart.01042.2011] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Diagnosis of the ischemic power of epicardial stenosis with concomitant microvascular disease (MVD) is challenging during coronary interventions, especially under variable hemodynamic factors like heart rate (HR). The goal of this study is to assess the influence of variable HR and percent area stenosis (%AS) in the presence of MVD on pressure drop coefficient (CDP; ratio of transstenotic pressure drop to the distal dynamic pressure) and lesion flow coefficient (LFC; ratio of %AS to the CDP at the throat region). We hypothesize that CDP and LFC are independent of HR. %AS and MVD were created using angioplasty balloons and 90-μm microspheres, respectively. Simultaneous measurements of pressure drop (DP) and velocity were done in 11 Yorkshire pigs. Fractional flow reserve (FFR), CDP, and LFC were calculated for the groups HR < 120 and HR > 120 beats/min, %AS < 50 and %AS > 50, and additionally for DP < 14 and DP > 14 mmHg, and analyzed using regression and ANOVA analysis. Regression analysis showed independence between HR and the FFR, CDP, and LFC while it showed dependence between %AS and the FFR, CDP, and LFC. In the ANOVA analysis, for the HR < 120 beats/min and HR > 120 beats/min groups, the values of FFR (0.82 ± 0.02 and 0.82 ± 0.02), CDP (83.15 ± 26.19 and 98.62 ± 26.04), and LFC (0.16 ± 0.03 and 0.15 ± 0.03) were not significantly different (P > 0.05). However, for %AS < 50 and %AS > 50, the FFR (0.89 ± 0.02 and 0.75 ± 0.02), CDP (35.97 ± 25.79.10 and 143.80 ± 25.41), and LFC (0.09 ± 0.03 and 0.22 ± 0.03) were significantly different (P < 0.05). A similar trend was observed between the DP groups. Under MVD conditions, FFR, CDP, and LFC were not significantly influenced by changes in HR, while they can significantly distinguish %AS and DP groups.
Collapse
Affiliation(s)
- S V Peelukhana
- School of Dynamic Systems, Department of Mechanical Engineering, University of Cincinnati, Cincinnati, Ohio 45220, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Effect of guidewire on contribution of loss due to momentum change and viscous loss to the translesional pressure drop across coronary artery stenosis: an analytical approach. Biomed Eng Online 2011; 10:51. [PMID: 21658283 PMCID: PMC3141581 DOI: 10.1186/1475-925x-10-51] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2011] [Accepted: 06/10/2011] [Indexed: 12/19/2022] Open
Abstract
Background Guidewire (GW) size and stenosis dimensions are the two major factors affecting the translesional pressure drop. Studying the combined effect of these parameters on the mean pressure drop (Δp) across the stenosis is of high practical importance. Methods In this study, time averaged mass and momentum conservation equations are solved analytically to obtain pressure drop-flow, Δp-Q, curves for three different percentage area blockages corresponding to moderate (64%), intermediate (80%), and severe (90%) stenoses. Stenosis is considered to be axisymmetric consisting of three different sections namely converging, throat, and diverging regions. Analytical expressions for pressure drop are obtained for each of these regions separately. Using this approach, effects of lesion length and GW insertion on the mean translesional pressure drop and its component (loss due to momentum change and viscous loss) are analyzed. Results and Conclusion It is observed that for a given percent area stenosis (AS), increase in the throat length only increases the viscous loss. However, increase in the severity of stenosis and GW insertion increase both loss due to momentum change and viscous loss. GW insertion has greater contribution to the rise in viscous loss (increase by 2.14 and 2.72 times for 64% and 90% AS, respectively) than loss due to momentum change (1.34% increase for 64% AS and 25% decrease for 90% AS). It also alters the hyperemic pressure drop in moderate (48% increase) to intermediate (30% increase) stenoses significantly. However, in severe stenoses GW insertion has a negligible effect (0.5% increase) on hyperemic translesional pressure drop. It is also observed that pressure drop in a severe stenosis is less sensitive to lesion length variation (4% and 14% increase in Δp for without and with GW, respectively) as compared to intermediate (10% and 30% increase in Δp for without and with GW, respectively) and moderate stenoses (22% and 48% increase in Δp for without and with GW, respectively). Based on the contribution of pressure drop components to the total translesional pressure drop, it is found that viscous losses are dominant in moderate stenoses, while in severe stenoses losses due to momentum changes are significant. It is also shown that this simple analytical solution can provide valuable information regarding interpretation of coronary diagnostic parameters such as fractional flow reserve (FFR).
Collapse
|
24
|
Konala BC, Das A, Banerjee RK. Influence of arterial wall-stenosis compliance on the coronary diagnostic parameters. J Biomech 2011; 44:842-7. [DOI: 10.1016/j.jbiomech.2010.12.011] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2010] [Revised: 12/08/2010] [Accepted: 12/08/2010] [Indexed: 11/17/2022]
|
25
|
Kolli KK, Banerjee RK, Peelukhana SV, Helmy TA, Leesar MA, Arif I, Schneeberger EW, Hand D, Succop P, Gottliebson WM, Effat MA. Influence of heart rate on fractional flow reserve, pressure drop coefficient, and lesion flow coefficient for epicardial coronary stenosis in a porcine model. Am J Physiol Heart Circ Physiol 2010; 300:H382-7. [PMID: 20935151 DOI: 10.1152/ajpheart.00412.2010] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
A limitation in the use of invasive coronary diagnostic indexes is that fluctuations in hemodynamic factors such as heart rate (HR), blood pressure, and contractility may alter resting or hyperemic flow measurements and may introduce uncertainties in the interpretation of these indexes. In this study, we focused on the effect of fluctuations in HR and area stenosis (AS) on diagnostic indexes. We hypothesized that the pressure drop coefficient (CDP(e), ratio of transstenotic pressure drop and distal dynamic pressure), lesion flow coefficient (LFC, square root of ratio of limiting value CDP and CDP at site of stenosis) derived from fluid dynamics principles, and fractional flow reserve (FFR, ratio of average distal and proximal pressures) are independent of HR and can significantly differentiate between the severity of stenosis. Cardiac catheterization was performed on 11 Yorkshire pigs. Simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual sensor-tipped guidewire for HR < 120 and HR > 120 beats/min, in the presence of epicardial coronary lesions of <50% AS and >50% AS. The mean values of FFR, CDP(e), and LFC were significantly different (P < 0.05) for lesions of <50% AS and >50% AS (0.88 ± 0.04, 0.76 ± 0.04; 62 ± 30, 151 ± 35, and 0.10 ± 0.02 and 0.16 ± 0.01, respectively). The mean values of FFR and CDP(e) were not significantly different (P > 0.05) for variable HR conditions of HR < 120 and HR > 120 beats/min (FFR, 0.81 ± 0.04 and 0.82 ± 0.04; and CDP(e), 95 ± 33 and 118 ± 36). The mean values of LFC do somewhat vary with HR (0.14 ± 0.01 and 0.12 ± 0.02). In conclusion, fluctuations in HR have no significant influence on the measured values of CDP(e) and FFR but have a marginal influence on the measured values of LFC. However, all three parameters can significantly differentiate between stenosis severities. These results suggest that the diagnostic parameters can be potentially used in a better assessment of coronary stenosis severity under a clinical setting.
Collapse
Affiliation(s)
- Kranthi K Kolli
- Department of Mechanical Engineering, University of Cincinnati, Cincinnati, Ohio 45221-0072, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Peelukhana SV, Back LH, Banerjee RK. Influence of coronary collateral flow on coronary diagnostic parameters: an in vitro study. J Biomech 2009; 42:2753-9. [PMID: 19775695 DOI: 10.1016/j.jbiomech.2009.08.013] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2009] [Revised: 07/30/2009] [Accepted: 08/01/2009] [Indexed: 02/06/2023]
Abstract
Functional severity of coronary stenosis is often assessed using diagnostic parameters. These parameters are evaluated from the combined pressure and/or flow measurements taken at the site of the stenosis. However, when there are functional collaterals operating downstream to the stenosis, the coronary flow-rate increases, and the pressure in the stenosed artery is altered. This effect of downstream collaterals on different diagnostic parameters is studied using a physiological representative in vitro coronary flow-loop. The three diagnostic parameters tested are fractional flow reserve (FFR), lesion flow coefficient (LFC), and pressure drop coefficient (CDP). The latter two were discussed in recent publications by our group (Banerjee et al., 2007, 2008, 2009). They are evaluated for three different severities of stenosis and tested for possible misinterpretation in the presence of variable collateral flows. Pressure and flow are measured with and without downstream collaterals. The diagnostic parameters are then calculated from these readings. In the case of intermediate stenosis (80% area blockage), FFR and LFC increased from 0.74 to 0.77 and 0.58 to 0.62, respectively, for no collateral to fully developed collateral flow. Also, CDP decreased from 47 to 42 for no collateral to fully developed collateral flow. These changes in diagnostic parameters might lead to erroneous postponement of coronary intervention. Thus, variability in diagnostic parameters for the same stenosis might lead to misinterpretation of stenosis severity in the presence of operating downstream collaterals.
Collapse
|
27
|
Banerjee RK, Ashtekar KD, Helmy TA, Effat MA, Back LH, Khoury SF. Hemodynamic diagnostics of epicardial coronary stenoses: in-vitro experimental and computational study. Biomed Eng Online 2008; 7:24. [PMID: 18752683 PMCID: PMC2556321 DOI: 10.1186/1475-925x-7-24] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2007] [Accepted: 08/27/2008] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true severity of epicardial stenosis, we evaluate a diagnostic parameter, which is obtained from fundamental fluid dynamics principles. This experimental and numerical study focuses on the characterization of the diagnostic parameter, pressure drop coefficient, and also evaluates the pressure recovery downstream of stenoses. METHODS Three models of coronary stenosis namely, moderate, intermediate and severe stenosis, were manufactured and tested in the in-vitro set-up simulating the epicardial coronary network. The trans-stenotic pressure drop and flow distal to stenosis models were measured by non-invasive method, using external pressure and flow sensors, and by invasive method, following guidewire insertion across the stenosis. The viscous and momentum-change components of the pressure drop for various flow rates were evaluated from quadratic relation between pressure drop and flow. Finally, the pressure drop coefficient (CDPe) was calculated as the ratio of pressure drop and distal dynamic pressure. The pressure recovery factor (eta) was calculated as the ratio of pressure recovery coefficient and the area blockage. RESULTS The mean pressure drop-flow characteristics before and during guidewire insertion indicated that increasing stenosis causes a shift in dominance from viscous pressure to momentum forces. However, for intermediate (approximately 80%) area stenosis, which is between moderate (approximately 65%) and severe (approximately 90%) area stenoses, both losses were similar in magnitude. Therefore, guidewire insertion plays a critical role in evaluating the hemodynamic severity of coronary stenosis. More importantly, mean CDPe increased (17 +/- 3.3 to 287 +/- 52, n = 3, p < 0.01) and mean eta decreased (0.54 +/- 0.04 to 0.37 +/- 0.05, p < 0.01) from moderate to severe stenosis during guidewire insertion. CONCLUSION The wide range of CDPe is not affected that much by the presence of guidewire. CDPe can be used in clinical practice to evaluate the true severity of coronary stenosis due to its significant difference between values measured at moderate and severe stenoses.
Collapse
Affiliation(s)
- Rupak K Banerjee
- Department of Mechanical, Industrial and Nuclear Engineering, 601B Rhodes Hall, University of Cincinnati, Clifton Avenue, Cincinnati, OH, USA
- Department of Biomedical Engineering, 598 Rhodes Hall, PO Box 210072, Cincinnati OH, 45221 0072, USA
| | - Koustubh D Ashtekar
- Department of Mechanical, Industrial and Nuclear Engineering, 601B Rhodes Hall, University of Cincinnati, Clifton Avenue, Cincinnati, OH, USA
| | - Tarek A Helmy
- Department of Internal Med-Cardiology, MSB, University of Cincinnati, Cincinnati, OH, USA
| | - Mohamed A Effat
- Department of Internal Med-Cardiology, MSB, University of Cincinnati, Cincinnati, OH, USA
| | - Lloyd H Back
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, USA
| | - Saeb F Khoury
- Department of Internal Med-Cardiology, MSB, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
28
|
Sinha Roy A, Back MR, Khoury SF, Schneeberger EW, Back LH, Velury VV, Millard RW, Banerjee RK. Functional and anatomical diagnosis of coronary artery stenoses. J Surg Res 2007; 150:24-33. [PMID: 18262546 DOI: 10.1016/j.jss.2007.10.018] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2007] [Revised: 10/16/2007] [Accepted: 10/21/2007] [Indexed: 02/07/2023]
Abstract
BACKGROUND Functional/physiological evaluation of coronary artery stenoses may be more important than anatomical measurements of severity. Optimization of thresholds for stenosis intervention and treatment endpoints depend on coupling functional hemodynamic and anatomical data. We sought to develop a single prognostic parameter correlating stenosis-specific anatomy, pressure gradient, and velocities that could be measured during catheterization. MATERIALS AND METHODS In vivo Experiments were performed in six swine (41 +/- 3 kg). The lumen area of the left anterior descending coronary artery was measured with intravascular ultrasound. An angioplasty balloon was inflated to create the desired intraluminal area obstructions. Fractional flow reserve (FFR), coronary flow reserve (CFR), and hyperemic-stenosis-resistance index were measured distal to the balloon at peak hyperemia with 10 mg intracoronary papaverine. A functional index:pressure drop coefficient (CDP) and a combined functional and anatomical index:lesion flow coefficient (LFC) were calculated from measured hyperemic pressure gradient, velocity, and percentage area stenosis. P < 0.05 was considered statistically significant. RESULTS The CDP and LFC correlated linearly and significantly with FFR and CFR. The CDP (R(2) = 0.72, P < 0.0001) correlated better than LFC (R(2) = 0.19, P < 0.003) with hyperemic-stenosis-resistance index. When LFC was correlated simultaneously with FFR and CFR, R(2) improved to 0.82 (P < 0.0001). Inclusion of percentage area stenoses concurrently with FFR and CFR marginally improved the correlation with LFC. CONCLUSIONS A dimensionless parameter combining measured pressure gradient, velocity, and area reduction data can optimally define the severity of coronary stenoses based on our preliminary results and could prove useful clinically.
Collapse
Affiliation(s)
- Abhijit Sinha Roy
- Department of Mechanical Engineering, University of Cincinnati, Cincinnati, Ohio 45221-0072, USA
| | | | | | | | | | | | | | | |
Collapse
|
29
|
Ashtekar KD, Back LH, Khoury SF, Banerjee RK. In Vitro Quantification of Guidewire Flow-Obstruction Effect in Model Coronary Stenoses for Interventional Diagnostic Procedure. J Med Device 2007. [DOI: 10.1115/1.2776336] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
|