1
|
Brewer C, Shakib A, de Lange JE, Quenneville CE. Estimation of Injury Limits at Vulnerable Impact Locations Along the Forearm Via THUMS AM50 Finite Element Model at Airbag Loading Rates. J Biomech Eng 2024; 146:091002. [PMID: 38511299 DOI: 10.1115/1.4065140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 02/27/2024] [Indexed: 03/22/2024]
Abstract
Side and frontal airbag deployment represents the main injury mechanism to the upper extremity during automotive collisions. Previous dynamic injury limit research has been limited to testing the forearm at either the assumed most vulnerable location to fracture, the distal 1/3rd, or the midpoint. Studies have varied the surface to which impacts were applied, with no clear consensus on the site of greatest vulnerability. The unpredictability of airbag impact location, especially with altered hand positioning, limits the effectiveness of existing forearm injury limits determined from impacts at only one location. The current study quantified the effect of impacts at alternative locations on injury risk along the forearm using the THUMS FE model. Airbag-level impacts were simulated along the forearm on all four anatomical surfaces. Results showed the distal 1/3rd is not the most vulnerable location (for any side), indicating forearm fracture is not solely driven by area moment of inertia (as previously assumed). The posterior forearm was the weakest, suggesting that current test standards underestimate the fracture risk of the forearm. Linear regression models showed strong correlation between forearm fracture risk and bone geometry (cross-sectional area and area moment of inertia) as well as soft-tissue depth, potentially providing the ability to predict forearm injury tolerances for any location or forearm size. This study demonstrated the forearm's vulnerability to fracture from airbag deployments, indicating the need for safety systems to better address injury mechanisms for the upper limb to effectively protect drivers.
Collapse
Affiliation(s)
- Carson Brewer
- Department of Mechanical Engineering, McMaster University, 1280 Main Street, West Hamilton, ON L8S 4L8, Canada
| | - Aryen Shakib
- School of Biomedical Engineering, McMaster University, 1280 Main Street, West Hamilton, ON L8S 4L8, Canada
| | - Julia E de Lange
- School of Biomedical Engineering, McMaster University, 1280 Main Street, West Hamilton, ON L8S 4L8, Canada
| | - Cheryl E Quenneville
- Department of Mechanical Engineering, McMaster University, 1280 Main Street, West Hamilton, ON L8S 4L8, Canada;School of Biomedical Engineering, McMaster University, 1280 Main Street, West Hamilton, ON L8S 4L8, Canada
| |
Collapse
|
2
|
Aslan L, Subasi O, Gedik CC, Birsel O, Lazoglu I, Demirhan M, Eren I. In silico analysis of rib force distribution in postscapulothoracic arthrodesis model. J Orthop Res 2024; 42:942-949. [PMID: 38111178 DOI: 10.1002/jor.25771] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 12/08/2023] [Accepted: 12/12/2023] [Indexed: 12/20/2023]
Abstract
Scapulothoracic arthrodesis (STA) is carried out by fixing the scapula to thoracic ribs which in turn allows the patient suffering from Facioscapulohumeral Muscular Dystrophy to carry out shoulder-joint dependent activities of daily living. A biomechanical analysis of this procedure has not been conducted in the literature and, for the first time, this study investigates the finite element calculated glenohumeral-applied load distributions on ribs by creating a post-STA model. Three loading directions on the glenohumeral joint are designated: anterior-posterior, superior-inferior, and lateral-medial. Reaction forces on the ribs are calculated based on the glenoid force percent. Simulations are repeated by removing a singular rib contact to observe the change in force distributions in the case of missing levels or failed bonding as well as the impact of clavicle osteotomy. Total load distribution is observed highest at T2 followed by T3 and T6. In the T2 missing scenario, total loads on T3 and T4 increase. In the T4 missing case, the most affected level is T3. In the T6 missing scenario, total loads on T5 and T7 increase. In the clavicular osteotomy scenario, all levels' loads increase; the highest is recorded in T7 by 460%, followed by T5, T4, T2, T6, and T3. While all levels contribute to fixation strength, T2 is subjected to the highest loads, and, in the missing level scenarios, the loads are tolerated sufficiently by the remaining levels. Missing T4 scenario has the least effect on the system, which is interpreted as potentially the only skippable level of fixation. Clavicular osteotomy has the highest effect on the arthrodesis site.
Collapse
Affiliation(s)
- Lercan Aslan
- Department of Orthopaedics and Traumatology, Koc University School of Medicine, Istanbul, Turkey
| | - Omer Subasi
- Foot & Ankle Research and Innovation Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
- Manufacturing and Automation Research Center, Koc University, Istanbul, Turkey
| | - Cemil Cihad Gedik
- Department of Orthopaedics and Traumatology, Koc University School of Medicine, Istanbul, Turkey
| | - Olgar Birsel
- Department of Orthopaedics and Traumatology, Koc University School of Medicine, Istanbul, Turkey
| | - Ismail Lazoglu
- Manufacturing and Automation Research Center, Koc University, Istanbul, Turkey
| | - Mehmet Demirhan
- Department of Orthopaedics and Traumatology, Koc University School of Medicine, Istanbul, Turkey
| | - Ilker Eren
- Department of Orthopaedics and Traumatology, Koc University School of Medicine, Istanbul, Turkey
| |
Collapse
|
3
|
Quevedo Gonzalez FJ, Lipman JD, Sculco PK, Sculco TP, De Martino I, Wright TM. An Anterior Spike Decreases Bone-Implant Micromotion in Cementless Tibial Baseplates for Total Knee Arthroplasty: A Biomechanical Study. J Arthroplasty 2024; 39:1323-1327. [PMID: 38000515 DOI: 10.1016/j.arth.2023.11.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 11/15/2023] [Accepted: 11/17/2023] [Indexed: 11/26/2023] Open
Abstract
BACKGROUND Cementless tibial baseplates in total knee arthroplasty include fixation features (eg, pegs, spikes, and keels) to ensure sufficient primary bone-implant stability. While the design of these features plays a fundamental role in biologic fixation, the effectiveness of anterior spikes in reducing bone-implant micromotion remains unclear. Therefore, we asked: Can an anterior spike reduce the bone-implant micromotion of cementless tibial implants? METHODS We performed computational finite element analyses on 13 tibiae using the computed tomography scans of patients scheduled for primary total knee arthroplasty. The tibiae were virtually implanted with a cementless tibial baseplate with 2 designs of fixation of the baseplate: 2 pegs and 2 pegs with an anterior spike. We compared the bone-implant micromotion under the most demanding loads from stair ascent between both designs. RESULTS Both fixation designs had peak micromotion at the anterior-lateral edge of the baseplate. The design with 2 pegs and an anterior spike had up to 15% lower peak micromotion and up to 14% more baseplate area with micromotions below the most conservative threshold for ingrowth, 20 μm, than the design with only 2 pegs. The greatest benefit of adding an anterior spike occurred for subjects who had the smallest area of tibial bone below the 20 μm threshold (ie, most at risk for failure to achieve bone ingrowth). CONCLUSIONS An anteriorly placed spike for cementless tibial baseplates with 2 pegs can help decrease the bone-implant micromotion during stair ascent, especially for subjects with increased bone-implant micromotion and risk for bone ingrowth failure.
Collapse
Affiliation(s)
| | - Joseph D Lipman
- Department of Biomechanics, Hospital for Special Surgery, New York
| | - Peter K Sculco
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York
| | - Thomas P Sculco
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York
| | - Ivan De Martino
- Department of Geriatric Science and Orthopaedics, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York
| |
Collapse
|
4
|
Xie Z, Chen X, Wang J, Chen J. Three-Dimensional Meso-Structure-Based Model for Evaluating the Complex Permittivity of Asphalt Concrete. Materials (Basel) 2024; 17:1900. [PMID: 38673257 PMCID: PMC11051777 DOI: 10.3390/ma17081900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2024] [Revised: 04/06/2024] [Accepted: 04/16/2024] [Indexed: 04/28/2024]
Abstract
Microwave heating is an emerging alternative pretreatment method for road maintenance in cold seasons. The thermal behavior of asphalt pavement under microwave heating is mainly determined by the complex permittivity of the asphalt mixture. In this study, an innovative approach for calculating the complex permittivity of an asphalt mixture based on a three-dimensional meso-scale heterogeneous structure was proposed. A series of experiments was conducted to verify the accuracy of this approach. The effect of porosity, void size, moisture content and aggregate gradation on the complex permittivity for an asphalt mixture were computationally analyzed based on the validated approach. Moreover, the applicability of commonly used classical dielectric models was analyzed. The classical Lichtenecker-Rother (LR) dielectric model was modified on the basis of simulation data for various conditions. The results showed that the real part of the complex permittivity decreased with the increase in porosity. Some sudden change in the imaginary part of the complex permittivity was observed within the frequency range from 2.6 GHz to 3.9 GHz. A larger air void size would lead to a larger frequency at which sudden change occurs. The real part and imaginary part of the complex permittivity tend to be smaller when more coarse aggregates are replaced with fine aggregates. Both the real part and the imaginary part of the complex permittivity increase with higher moisture content due to the stronger dielectric property of water. Each 1% increase in moisture content would lead to about a 3~4% increase in the real part of the complex permittivity. The determination coefficients R2 for the real part and the imaginary part of the complex permittivity fitted by the modified Brown model were the maximum values, which were 0.922 and 0.980, respectively. The method presented in this study is useful for transportation agencies to optimize microwave heating during winter maintenance.
Collapse
Affiliation(s)
- Zhenwen Xie
- Hunan Construction Investment Group Co., Ltd., Changsha 410004, China;
| | - Xingzao Chen
- Department of Civil Engineering, Central South University, Changsha 410075, China; (X.C.); (J.W.)
| | - Jing Wang
- Department of Civil Engineering, Central South University, Changsha 410075, China; (X.C.); (J.W.)
| | - Jiaqi Chen
- Department of Civil Engineering, Central South University, Changsha 410075, China; (X.C.); (J.W.)
| |
Collapse
|
5
|
Zhou Y, Zhuang J, Lin W, Xu W, Hu R. Creep and Shrinkage Properties of Nano-SiO 2-Modified Recycled Aggregate Concrete. Materials (Basel) 2024; 17:1904. [PMID: 38673261 PMCID: PMC11052056 DOI: 10.3390/ma17081904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 04/12/2024] [Accepted: 04/16/2024] [Indexed: 04/28/2024]
Abstract
The poor performance of recycled concrete aggregate (RCA) leads to greater creep in recycled aggregate concrete (RAC) compared to natural aggregate concrete (NAC). To enhance the quality of RCA, this paper utilizes a 2% concentration of a nano-SiO2 (NS) solution for pre-soaking RCA. This study aims to replace natural aggregate (NA) with NS-modified recycled aggregate (SRCA) and investigate the creep and shrinkage properties of NS-modified recycled aggregate concrete (SRAC) at various SRCA replacement rates. Subsequently, the creep and shrinkage strains of NAC, SRAC, and RAC are simulated using the finite element method. Finally, a comparative analysis is conducted with the predicted creep and shrinkage strains from CEB-FIP, ACI, B3, and GL2000 models. The experimental results indicate that the creep and shrinkage deformation of SRAC increases with the SRCA replacement rate. Compared to NAC, the creep and shrinkage deformation of SRAC at replacement rates of 30%, 50%, 70%, and 100% increased by 2%, 7%, 13%, and 30%, respectively. However, when 100% of the natural aggregate is replaced with SRCA, the creep and shrinkage deformation decreases by 7% compared to RAC. Moreover, the CEB-FIP and ACI models can predict the creep and shrinkage deformation of concrete reasonably well.
Collapse
Affiliation(s)
| | | | | | | | - Rui Hu
- Guangdong Provincial Key Laboratory of Durability for Marine Civil Engineering, Shenzhen University, Shenzhen 518060, China; (Y.Z.); (J.Z.); (W.L.); (W.X.)
| |
Collapse
|
6
|
Rahmayanti ZA, Aripin D, Muryani A, Yolanda Y, Dharsono HDA, Mihradi S, Wicaksono S. Stress Distribution of Endodontically Treated Tooth MOD Cavity Restored with Ribbon Fiber-Reinforced Composite (Wallpapering Technique) Using Finite Element Method. Clin Cosmet Investig Dent 2024; 16:91-99. [PMID: 38650600 PMCID: PMC11034570 DOI: 10.2147/ccide.s450458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 03/26/2024] [Indexed: 04/25/2024] Open
Abstract
Purpose This research aimed to describe the stress distribution of an endodontically treated tooth with a mesio-occluso-distal (MOD) cavity restored with direct composite reinforced with polyethylene and e-glass ribbon fiber. Methods This research was a descriptive study using the finite element method. A 3D model of the mandibular first molar solid after endodontic treatment with class II MOD preparation was prepared using Solidworks software. Finite element simulation was carried out using Abaqus software. In the first simulation, 180 N force was applied (vertically 90° perpendicular to the occlusal surface) at four points of loading: the tip of the mesiobuccal and distobuccal cusp, central fossa, and distal marginal ridge. For the second simulation, a 100 N force was applied at a 45° lateral angle to the occlusal surface at two loading points: the lingual slope of the mesiobuccal and distobuccal cusp. Results This study showed that the stress concentration was located in the occlusal pit and fissure, CEJ distal area, bifurcation in dentin, and the 1/3 cervical area of root dentin. The stress value generated after vertical and lateral force did not exceed the tooth and restoration's compressive and tensile strength value. The failure occurred at the interface of enamel and composite near the loading point area due to vertical load, both on polyethylene and e-glass fiber ribbon-reinforced composite restoration. Stress distribution of an endodontically treated tooth with a MOD cavity restored with ribbon fiber-reinforced composite using the finite element method showed that the highest stress concentration occurred on the surface close to the loading point, in narrow, concave, and sharp areas, and more apically for endodontically treated teeth. Conclusion Neither the tooth nor restoration failed after vertical and horizontal loads. The interface between enamel and composite on the occlusal surface failed.
Collapse
Affiliation(s)
- Zenita Aisah Rahmayanti
- Department of Conservative Dentistry, Faculty of Dentistry, Universitas Padjadjaran, Bandung, Indonesia
| | - Dudi Aripin
- Department of Conservative Dentistry, Faculty of Dentistry, Universitas Padjadjaran, Bandung, Indonesia
| | - Anna Muryani
- Department of Conservative Dentistry, Faculty of Dentistry, Universitas Padjadjaran, Bandung, Indonesia
| | - Yolanda Yolanda
- Department of Conservative Dentistry, Faculty of Dentistry, Universitas Padjadjaran, Bandung, Indonesia
| | | | - Sandro Mihradi
- Faculty of Mechanical and Aerospace Engineering, Bandung Institute of Technology, Bandung, Indonesia
| | - Satrio Wicaksono
- Faculty of Mechanical and Aerospace Engineering, Bandung Institute of Technology, Bandung, Indonesia
| |
Collapse
|
7
|
Stoddart JC, Garner A, Tuncer M, Amis AA, Cobb J, van Arkel RJ. Load transfer in bone after partial, multi-compartmental, and total knee arthroplasty. Front Bioeng Biotechnol 2024; 12:1274496. [PMID: 38524193 PMCID: PMC10957574 DOI: 10.3389/fbioe.2024.1274496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 01/24/2024] [Indexed: 03/26/2024] Open
Abstract
Introduction: Arthroplasty-associated bone loss remains a clinical problem: stiff metallic implants disrupt load transfer to bone and, hence, its remodeling stimulus. The aim of this research was to analyze how load transfer to bone is affected by different forms of knee arthroplasty: isolated partial knee arthroplasty (PKA), compartmental arthroplasty [combined partial knee arthroplasty (CPKA), two or more PKAs in the same knee], and total knee arthroplasty (TKA). Methods: An experimentally validated subject-specific finite element model was analyzed native and with medial unicondylar, lateral unicondylar, patellofemoral, bi-unicondylar, medial bicompartmental, lateral bicompartmental, tricompartmental, and total knee arthroplasty. Three load cases were simulated for each: gait, stair ascent, and sit-to-stand. Strain shielding and overstraining were calculated from the differences between the native and implanted states. Results: For gait, the TKA femoral component led to mean strain shielding (30%) more than three times higher than that of PKA (4%-7%) and CPKA (5%-8%). Overstraining was predicted in the proximal tibia (TKA 21%; PKA/CPKA 0%-6%). The variance in the distribution for TKA was an order of magnitude greater than for PKA/CPKA, indicating less physiological load transfer. Only the TKA-implanted femur was sensitive to the load case: for stair ascent and gait, almost the entire distal femur was strain-shielded, whereas during sit-to-stand, the posterior femoral condyles were overstrained. Discussion: TKA requires more bone resection than PKA and CPKA. These finite element analyses suggest that a longer-term benefit for bone is probable as partial and multi-compartmental knee procedures lead to more natural load transfer compared to TKA. High-flexion activity following TKA may be protective of posterior condyle bone resorption, which may help explain why bone loss affects some patients more than others. The male and female bone models used for this research are provided open access to facilitate future research elsewhere.
Collapse
Affiliation(s)
- Jennifer C. Stoddart
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| | - Amy Garner
- Msk Lab, Department of Surgery and Cancer, Imperial College London, London, United Kingdom
- Dunhill Medical Trust and Royal College of Surgeons of England Joint Research Fellowship, London, United Kingdom
- Nuffield Orthopaedic Centre, Oxford Universities NHS Trust, Oxford, United Kingdom
| | | | - Andrew A. Amis
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| | - Justin Cobb
- Msk Lab, Department of Surgery and Cancer, Imperial College London, London, United Kingdom
| | - Richard J. van Arkel
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| |
Collapse
|
8
|
Zhang IP, Cohen GN, Damato AL. A finite element method for modeling diffusion of alpha-emitting particles in tissue. Med Phys 2024; 51:2263-2276. [PMID: 37878762 DOI: 10.1002/mp.16803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Revised: 10/04/2023] [Accepted: 10/04/2023] [Indexed: 10/27/2023] Open
Abstract
BACKGROUND Diffusing alpha-emitters Radiation Therapy ("DaRT") is a promising new modality for the treatment of solid tumors. Interstitial sources containing 224 Ra are inserted into the tumor, producing alpha particles via the decay of 224 Ra and its daughters. The alpha particles are able to produce a "kill region" of several mm due to the diffusion of the alpha-emitting atoms. The Diffusion-Leakage (D-L) model has been proposed to describe the movement of the alpha-emitters used in DaRT in tumor tissue. PURPOSE To date, estimating the dose delivered under the D-L model has been accomplished with numerical solutions based on finite difference methods, namely DART1D and DART2D, as well as with asymptotic expressions for the long time limit. The aim of this work is to develop a flexible method of finite elements for solving the D-L model and to validate prior solutions of the D-L model. METHODS We develop a two-dimensional finite element solution to the D-L model implemented using the FEniCS software library. Our approach solves the variational formulation of the D-L equations on an unstructured mesh of triangular Lagrangian elements. We calculate the local dose in the mid- and axial planes of the source and validate our results against the one- and two-dimensional solutions obtained using the previously proposed numerical scheme, DART1D and DART2D. We use our model to estimate the change in dose in the source midplane as a function of the physical parameters used in the D-L model. RESULTS The local dose at the end of a 30 day treatment period estimated by our numerical method differs from DART1D and DART2D by less than 1% in the source midplane and less than 3% along the source axis over clinically relevant distances, with the largest discrepancies in high gradient areas where the Finite Element Method (FEM) mesh has a higher element density. We find that within current experimentally estimated ranges for D-L model parameters, the dose in the source midplane at a distance of 2 mm can vary by over a factor of 3. CONCLUSIONS The 2D finite element model reproduces the calculated dose obtained with DART1D and DART2D under the assumptions D-L model. The variation in predicted dose within current experimental ranges for model parameters suggests the necessity of further studies to better determine their statistical distributions. Finally, the FEM model can be used to calculate dose from DaRT in a variety of realistic 2D geometries beyond the D-L model.
Collapse
Affiliation(s)
- Irene P Zhang
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York City, New York, USA
| | - Gilad N Cohen
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York City, New York, USA
| | - Antonio L Damato
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York City, New York, USA
| |
Collapse
|
9
|
Li Z, Pollard S, Smith G, Deshmukh S, Ding Z. Biomechanical analysis of combi-hole locking compression plate during fracture healing: A numerical study of screw configuration. Proc Inst Mech Eng H 2024; 238:313-323. [PMID: 38372206 PMCID: PMC10941711 DOI: 10.1177/09544119241229157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 01/12/2024] [Indexed: 02/20/2024]
Abstract
Locking compression plates (LCPs) have become a widely used option for treating femur bone fractures. However, the optimal screw configuration with combi-holes remains a subject of debate. The study aims to create a time-dependent finite element (FE) model to assess the impacts of different screw configurations on LCP fixation stiffness and healing efficiency across four healing stages during a complete fracture healing process. To simulate the healing process, we integrated a time-dependent callus formation mechanism into a FE model of the LCP with combi-holes. Three screw configuration parameters, namely working length, screw number, and screw position, were investigated. Increasing the working length negatively affected axial stiffness and healing efficiency (p < 0.001), while screw number or position had no significant impact (p > 0.01). The time-dependent model displayed a moderate correlation with the conventional time-independent model for axial stiffness and healing efficiency (ρ ≥ 0.733, p ≤ 0.025). The highest healing efficiency (95.2%) was observed in screw configuration C125 during the 4-8-week period. The results provide insights into managing fractures using LCPs with combi-holes over an extended duration. Under axial compressive loading conditions, the use of the C125 screw configuration can enhance callus formation during the 4-12-week period for transverse fractures. When employing the C12345 configuration, it becomes crucial to avoid overconstraint during the 4-8-week period.
Collapse
Affiliation(s)
- Zeyang Li
- School of Engineering, Cardiff University, Cardiff, UK
| | - Stuart Pollard
- School of Engineering, University of Birmingham, Birmingham, UK
| | | | | | - Ziyun Ding
- School of Engineering, University of Birmingham, Birmingham, UK
| |
Collapse
|
10
|
Ma P, Li Z, Miao J, Zhang X, Zong Z, Li T. Finite element analysis of different pedicle screw internal fixations for first lumbar vertebral fracture in different sports conditions. J Int Med Res 2024; 52:3000605241236054. [PMID: 38468383 DOI: 10.1177/03000605241236054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/13/2024] Open
Abstract
OBJECTIVE Lumbar fractures are the most common spinal injuries, and surgery is required for severe fracture. This study aimed to investigate the variations in motion and stress in varying states of activity after minimally invasive and traditional open pedicle screw placement for L1 vertebral fracture stabilization. METHODS We studied a male volunteer (26 years old) with no history of chronic back pain or lumbar spine trauma. We used the finite element method for this investigation. Using finite element software, we created a three-dimensional model of L1 vertebral compression fracture. We also constructed models for four percutaneous pedicle screws spanning the fractured vertebra and four screws traversing the damaged vertebra with transverse fixation. RESULTS In all three-dimensional movement directions, the open pedicle fixation system experienced maximum stress higher than its percutaneous counterpart. With axial spinal rotation, von Mises stress on the traditional open pedicle screw was considerably lower than that with percutaneous pedicle fixation, but peak stress was elevated at the transverse connection. Traditional open pedicle fixation displayed less maximum displacement than percutaneous pedicle internal fixation. CONCLUSIONS During axial spinal movements, high peak stress is observed at the transverse connection. Patients should avoid excessive axial rotation of the spine during recovery.
Collapse
Affiliation(s)
- Pengpeng Ma
- Clinical School/College of Orthopedics, Tianjin Medical University, Tianjin, China
- Department of Orthopedics, First Affiliated Hospital of Hebei North University, Zhangjiakou, China
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
| | - Zhenyu Li
- Clinical School/College of Orthopedics, Tianjin Medical University, Tianjin, China
| | - Jun Miao
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
| | - Xin Zhang
- Department of Orthopedics, First Affiliated Hospital of Hebei North University, Zhangjiakou, China
| | - Zhiguo Zong
- Department of Orthopedics, First Affiliated Hospital of Hebei North University, Zhangjiakou, China
| | - Tian Li
- School of Basic Medicine, Fourth Military Medical University, Xi'an, China
| |
Collapse
|
11
|
Li JR, Yan Y, Wu XG, He LM, Feng HY. Biomechanical evaluation of Percutaneous endoscopic posterior lumbar interbody fusion and minimally invasive transforaminal lumbar interbody fusion: a biomechanical analysis. Comput Methods Biomech Biomed Engin 2024; 27:285-295. [PMID: 36847747 DOI: 10.1080/10255842.2023.2183348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 02/12/2023] [Accepted: 02/15/2023] [Indexed: 03/01/2023]
Abstract
In order to analyze and evaluate the stability of lumbar spine and the risk of cage subsidence after different minimally invasive fusion operations, two finite element models Percutaneous endoscopic posterior lumbar interbody fusion (PE-PLIF) and minimally invasive transforaminal lumbar interbody Fusion (MIS-TLIF) were established. The results showed that compared with MIS-TLIF, PE-PLIF had better segmental stability, lower pedicle screw rod system stress, and lower risk of cage subsidence. The results suggest that the cage with appropriate height should be selected to ensure the segmental stability and avoid the risk of the subsidence caused by the cage with large height.
Collapse
Affiliation(s)
- Jia-Rui Li
- Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, China
| | - Yang Yan
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, China
| | - Xiao-Gang Wu
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, China
| | - Li-Ming He
- Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, China
| | - Hao-Yu Feng
- Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, China
| |
Collapse
|
12
|
Incze-Bartha Z, Incze-Bartha S, Simon-Szabó Z, Feier AM, Vunvulea V, Nechifor-Boila AI, Pastorello Y, Denes L. Finite Element Analysis of Various Osteotomies Used in the Treatment of Developmental Hip Dysplasia in Children. J Pers Med 2024; 14:189. [PMID: 38392622 PMCID: PMC10889920 DOI: 10.3390/jpm14020189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 01/21/2024] [Accepted: 02/03/2024] [Indexed: 02/24/2024] Open
Abstract
Late-discovered developmental hip dysplasia deformities often necessitate complex surgical treatments and meticulous preoperative planning. The selection of osteotomies is contingent upon the patient's age and the specific structural deformity of the hip. In our anatomical hip model, derived from the data of a 12-year-old patient, we performed virtual osteotomies that are commonly recommended for such cases. We precisely constructed geometric models for various osteotomies, including the Dega, Pemberton, Tönnis, Ganz, Chiari pelvic, and Pauwels femoral osteotomies. We employed Autodesk Inventor for the finite element analysis of the hip joint and the corrective osteotomies. In comparing one-stage osteotomies, we noted that the Dega and Ganz pelvic osteotomies, especially when combined with the Pauwels femoral osteotomy, yielded the most favorable outcomes. These combinations led to enhanced femoral head coverage and reduced intra-articular pressure. Furthermore, we calculated the femoral head-to-acetabulum volume ratio for both the Dega and Pauwels osteotomies. The encouraging results we obtained advocate for the integration of finite element analysis in virtual osteotomies of the pelvis and femur as a preoperative tool in the management of developmental hip dysplasia.
Collapse
Affiliation(s)
- Zsuzsanna Incze-Bartha
- Department of Anatomy, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Sandor Incze-Bartha
- Department of Orthopedics and Traumatology, "Fogolyan Kristof" County Hospital Sfantu Gheorghe, 520064 Covasna, Romania
| | - Zsuzsánna Simon-Szabó
- Department of Pathophysiology, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Andrei Marian Feier
- Department of Orthopaedics and Traumatology, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540142 Targu Mures, Romania
| | - Vlad Vunvulea
- Department of Anatomy, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Alin Ioan Nechifor-Boila
- Department of Anatomy, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Ylenia Pastorello
- Department of Anatomy, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Lorand Denes
- Department of Anatomy, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
| |
Collapse
|
13
|
D'Andrea L, Gastaldi D, Baino F, Verné E, Schwentenwein M, Örlygsson G, Vena P. Computational models for the simulation of the elastic and fracture properties of highly porous 3D-printed hydroxyapatite scaffolds. Int J Numer Method Biomed Eng 2024; 40:e3795. [PMID: 37997203 DOI: 10.1002/cnm.3795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 09/29/2023] [Accepted: 11/05/2023] [Indexed: 11/25/2023]
Abstract
Bone scaffolding is a promising approach for the treatment of critical-size bone defects. Hydroxyapatite can be used to produce highly porous scaffolds as it mimics the mineralized part of bone tissue, but its intrinsic brittleness limits its usage. Among 3D printing techniques, vat photopolymerization allows for the best printing resolution for ceramic materials. In this study, we implemented a Computed micro-Tomography based Finite Element Model of a hydroxyapatite porous scaffold fabricated by vat photopolymerization. We used the model in order to predict the elastic and fracture properties of the scaffold. From the stress-strain diagram of a simulated compression test, we computed the stiffness and the strength of the scaffolds. We found that three morphometric features substantially affect the crack pattern. In particular, the crack propagation is not only dependent on the trabecular thickness but also depends on the slenderness and orientation of the trabeculae with respect to the load. The results found in this study can be used for the design of ceramic scaffolds with heterogeneous pore distribution in order to tailor and predict the compressive strength.
Collapse
Affiliation(s)
- Luca D'Andrea
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Dario Gastaldi
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Francesco Baino
- Institute of Materials Physics and Engineering, Department of Applied Science and Technology, Politecnico di Torino, Institute of Materials Physics and Engineering, Turin, Italy
| | - Enrica Verné
- Institute of Materials Physics and Engineering, Department of Applied Science and Technology, Politecnico di Torino, Institute of Materials Physics and Engineering, Turin, Italy
| | | | | | - Pasquale Vena
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| |
Collapse
|
14
|
Morany A, Bardon RG, Lavon K, Hamdan A, Bluestein D, Haj-Ali R. Analysis of fibrocalcific aortic valve stenosis: computational pre-and-post TAVR haemodynamics behaviours. R Soc Open Sci 2024; 11:230905. [PMID: 38384780 PMCID: PMC10878817 DOI: 10.1098/rsos.230905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Accepted: 01/22/2024] [Indexed: 02/23/2024]
Abstract
Fibro-calcific aortic valve (AV) diseases are characterized by calcium growth or accumulation of fibrosis in the AV tissues. Fibrocalcific aortic stenosis (FAS) rises specifically in females, like calcification-induced aortic stenosis (CAS), may eventually necessitate valve replacement. Fluid-structure-interaction (FSI) computational models for severe CAS and FAS patients were developed using lattice Boltzmann method and multi-scale finite elements (FE). Three parametric AV models were introduced: pathology-free of non-calcified tri-and-bicuspid AVs with healthy collagen fibre network (CFN), a FAS model incorporated a thickened CFN with embedded small calcification volumes, and a CAS model employs healthy CFN with embedded high calcification volumes. The results indicate that the interaction between calcium deposits, adjacent tissue and fibres crucially influences haemodynamics and structural reactions. A fourth model of transcatheter aortic valve replacement (TAVR) post-procedure outcomes was created to study both CAS and FAS. TAVR-CAS had a higher maximum contact pressure and lower anchoring area than TAVR-FAS, making it prone to aortic tissue damage and migration. Finally, although the TAVR-CAS offered a larger opening area, its paravalvular leakage was higher. This may be attributed to a similar thrombogenicity potential characterizing both models. The computational framework emphasizes the significance of mechanobiology in FAS and underscores the requirement for tissue modelling at multiple scales.
Collapse
Affiliation(s)
- Adi Morany
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel
| | | | - Karin Lavon
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Ashraf Hamdan
- Department of Cardiology, Rabin Medical Center, Petach Tikva, Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Rami Haj-Ali
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| |
Collapse
|
15
|
Pradhan EM, Lange J. Warping Torsion in Sandwich Panels: Analyzing the Structural Behavior through Experimental and Numerical Studies. Materials (Basel) 2024; 17:460. [PMID: 38255629 DOI: 10.3390/ma17020460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/10/2024] [Accepted: 01/16/2024] [Indexed: 01/24/2024]
Abstract
Recently, there has been a growing interest in the use of sandwich panels that, beyond handling well-known bending stress, can withstand torsional stresses. This is particularly relevant for wall applications when the panels are equipped with photovoltaic or supplemental curtain wall modules. This research article presents a detailed exploration of the structural behavior of eccentrically loaded sandwich panels, with a specific focus on warping torsion. Experimental and numerical studies were conducted on polyisocyanurate (PU) core sandwich panels, commonly employed in building envelopes. These studies involved various dimensions and material properties, while omitting longitudinal joints. The experimental study provided essential insights and validated the numerical model in ANSYS. Enabling parametric variation, the numerical analysis extends the analysis beyond the experimental scope. Results revealed a high degree of correlation between experimental, numerical, and analytical solutions, regarding the rotation, as well as the normal and shear stress of the panel. Confirming the general applicability of warping torsion in sandwich panels with certain limitations, the study contributes valuable data for applications and design of eccentrically loaded sandwich panels, laying the foundation for potential engineering calculation methods.
Collapse
Affiliation(s)
- Eric Man Pradhan
- Institute for Steel Construction and Materials Mechanics, Technical University of Darmstadt, 64287 Darmstadt, Germany
| | - Jörg Lange
- Institute for Steel Construction and Materials Mechanics, Technical University of Darmstadt, 64287 Darmstadt, Germany
| |
Collapse
|
16
|
Guitteny S, Lee CF, Amirouche F. Experimentally Validated Finite Element Analysis of Thoracic Spine Compression Fractures in a Porcine Model. Bioengineering (Basel) 2024; 11:96. [PMID: 38247973 PMCID: PMC10813756 DOI: 10.3390/bioengineering11010096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 12/22/2023] [Accepted: 01/11/2024] [Indexed: 01/23/2024] Open
Abstract
Vertebral compression fractures (VCFs) occur in 1 to 1.5 million patients in the US each year and are associated with pain, disability, altered pulmonary function, secondary vertebral fracture, and increased mortality risk. A better understanding of VCFs and their management requires preclinical models that are both biomechanically analogous and accessible. We conducted a study using twelve spinal vertebrae (T12-T14) from porcine specimens. We created mathematical simulations of vertebral compression fractures (VCFs) using CT scans for reconstructing native anatomy and validated the results by conducting physical axial compression experiments. The simulations accurately predicted the behavior of the physical compressions. The coefficient of determination for stiffness was 0.71, the strength correlation was 0.88, and the failure of the vertebral bodies included vertical splitting on the lateral sides or horizontal separation in the anterior wall. This finite element method has important implications for the preventative, prognostic, and therapeutic management of VCFs. This study also supports the use of porcine specimens in orthopedic biomechanical research.
Collapse
Affiliation(s)
- Sacha Guitteny
- Department of Orthopaedic Surgery, University of Illinois College of Medicine at Chicago, Chicago, IL 60607, USA; (S.G.); (C.F.L.)
| | - Cadence F. Lee
- Department of Orthopaedic Surgery, University of Illinois College of Medicine at Chicago, Chicago, IL 60607, USA; (S.G.); (C.F.L.)
| | - Farid Amirouche
- Department of Orthopaedic Surgery, University of Illinois College of Medicine at Chicago, Chicago, IL 60607, USA; (S.G.); (C.F.L.)
- Orthopaedic and Spine Institute, NorthShore University Health System, Chicago, IL 60611, USA
| |
Collapse
|
17
|
Waller J, Gowans P, Lord S, McGill K. Impact of Stoma Baseplate Convexity on Tension and Compression Around the Stoma Site: A Finite Element Analysis. Cureus 2024; 16:e52112. [PMID: 38213939 PMCID: PMC10783598 DOI: 10.7759/cureus.52112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/08/2024] [Indexed: 01/13/2024] Open
Abstract
For patients living with intestinal or urinary stomas, skin barriers play an essential role in protecting the peristomal skin and preventing peristomal complications. Convex baseplates press into the peristomal skin and are suitable for retracted stomas that do not protrude, peristomal skin with creases, folds, or dips, and stomas where frequent leaking can occur with flat pouching systems. However, there is a lack of data on the magnitude and location of tension applied to the abdomen by convex baseplates. We evaluated the impact of a range of convex baseplates applied to a simulated stoma site. A comparative finite element analysis investigation was conducted to evaluate the impact of eight different convex stoma system baseplates applied to an idealised flat abdomen, representing skin, subcutaneous tissue, and musculature layers. The baseplates considered had varying convexity with depths of 3.5 mm and 7 mm and internal structural diameters between ~30 mm and ~60 mm. The convex product range provided tension in the skin (maximum principal strain) and compression through the fat layer (minimum principal strain). Large differences in the locations and magnitudes of skin tension and fat layer compression were seen between the baseplates under analysis, with both the depth and diameter of convexity influencing the strain experienced across the abdominal topography. The results generated highlight the importance of having an appropriate range of convexity products available and selecting an appropriate option for use based on the stoma type and condition of the peristomal skin.
Collapse
Affiliation(s)
| | | | | | - Katie McGill
- Engineering, Kinneir Dufort Design Ltd., Bristol, GBR
| |
Collapse
|
18
|
Shen Y, Tang X, Lin S, Jin X, Ding J, Shao M. Automatic dose prediction using deep learning and plan optimization with finite-element control for intensity modulated radiation therapy. Med Phys 2024; 51:545-555. [PMID: 37748133 DOI: 10.1002/mp.16743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 07/21/2023] [Accepted: 08/26/2023] [Indexed: 09/27/2023] Open
Abstract
BACKGROUND Automatic solutions for generating radiotherapy treatment plans using deep learning (DL) have been investigated by mimicking the voxel's dose. However, plan optimization using voxel-dose features has not been extensively studied. PURPOSE This study aims to investigate the efficiency of a direct optimization strategy with finite elements (FEs) after DL dose prediction for automatic intensity-modulated radiation therapy (IMRT) treatment planning. METHODS A double-UNet DL model was adapted for 220 cervical cancer patients (200 for training and 20 for testing), who underwent IMRT between 2016 and 2020 at our clinic. The model inputs were computed tomography (CT) slices, organs at risk (OARs), and planning target volumes (PTVs), and the outputs were dose distributions of uniformly generated high-dose region-controlled plans. The FEs were discretized into equal intervals of the dose prediction value within the [OARs avoid PTV(O-P)] and [body avoids OARs & PTV(B-OP)] regions in the test cohort and used to define the objectives for IMRT plan optimization. The plans were optimized using a two-step process. In the beginning, the plans of two extra cases with and without low-dose region control were compared to pursue robust and optimal dose adjustment degree pattern of FEs. In the first step, the mean dose of O-P FEs were constrained to differing degrees according to the pattern. The further the FEs from the PTV, the tighter the constraints. In the second step, the mean dose of O-P FEs from first step were constrained again but weakly and the dose of the B-OP FEs from dose prediction and PTV were tightly regulated. The dosimetric parameters of the OARs and PTV were evaluated and compared using an interstep approach. In another 10 cases, the plans optimized via the aforementioned steps (method 1) were compared with those directly generated by the double-UNet dose prediction model trained by low and high region-controlled plans (method 2). RESULTS The mean differences in dose metrics between the UNet-predicted dose and the clinical plans were: 0.47 Gy for bladder D50% ; 0.62 Gy for rectum D50% ; 0% for small intestine V30Gy ; 1% for small intestine V40Gy ; 4% for left femoral head V30Gy ; and 6% for right femoral head V30Gy . The reductions in mean dose (p < 0.001) after FE-based optimization were: 4.0, 1.9, 2.8, 5.9, and 5.7 Gy for the bladder, rectum, small intestine, left femoral head, and right femoral head, respectively, with flat PTV homogeneity and conformity. Method 1 plans produced lower mean doses than those of method 2 for the bladder (0.7 Gy), rectum (1.0 Gy), and small intestine (0.6 Gy), while maintaining PTV homogeneity and conformity. CONCLUSION FE-based direct optimization produced lower OAR doses and adequate PTV doses after DL prediction. This solution offers rapid and automatic plan optimization without manual adjustment, particularly in low-dose regions.
Collapse
Affiliation(s)
- Yichao Shen
- Department of Radiation Oncology, Taizhou Hospital, Taizhou, Zhejiang, People's Republic of China
| | - Xingni Tang
- Department of Radiation Oncology, Taizhou Hospital, Taizhou, Zhejiang, People's Republic of China
| | - Sara Lin
- Petrone associates, Staten Island, New York, USA
| | - Xiance Jin
- Radiotherapy Center Department, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People's Republic of China
| | - Jiapei Ding
- Department of Radiation Oncology, Taizhou Hospital, Taizhou, Zhejiang, People's Republic of China
| | - Minghai Shao
- Department of Radiation Oncology, Taizhou Hospital, Taizhou, Zhejiang, People's Republic of China
| |
Collapse
|
19
|
Cunningham DE, Spangenberg GW, Langohr GDG, Athwal GS, Johnson JA. Stemless reverse humeral component neck-shaft angle has an influence on initial fixation. J Shoulder Elbow Surg 2024; 33:164-171. [PMID: 37507001 DOI: 10.1016/j.jse.2023.06.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Revised: 06/12/2023] [Accepted: 06/24/2023] [Indexed: 07/30/2023]
Abstract
BACKGROUND Stemless anatomic humeral components are commonly used and are an accepted alternative to traditional stemmed implants in patients with good bone quality. Presently, little literature exists on the design and implantation parameters that influence primary time-zero fixation of stemless reverse humeral implants. Accordingly, this finite element analysis study assessed the surgical implantation variable of neck-shaft angle, and its effect on the primary time-zero fixation of reversed stemless humeral implants. METHODS Eight computed tomography-derived humeral finite element models were used to examine a generic stemless humeral implant at varying neck-shaft angles of 130°, 135°, 140°, 145°, and 150°. Four loading scenarios (30° shoulder abduction with neutral forearm rotation, 30° shoulder abduction with forearm supination, a head-height lifting motion, and a single-handed steering motion) were employed. Implantation inclinations were compared based on the maximum bone-implant interface distraction detected after loading. RESULTS The implant-bone distraction was greatest in the 130° neck-shaft angle implantation cases. All implant loading scenarios elicited significantly lower micromotion magnitudes when neck-shaft angle was increased (P = .0001). With every 5° increase in neck-shaft angle, there was an average 17% reduction in bone-implant distraction. CONCLUSIONS The neck-shaft angle of implantation for a stemless reverse humeral component is a modifiable parameter that appears to influence time-zero implant stability. Lower, more varus, neck-shaft angles increase bone-implant distractions with simulated activities of daily living. It is therefore suggested that humeral head osteotomies at a higher neck-shaft angle may be beneficial to maximize stemless humeral component stability.
Collapse
Affiliation(s)
- David E Cunningham
- Department of Mechanical Engineering, The University of Western Ontario, London, ON, Canada; The Roth|McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada.
| | - Gregory W Spangenberg
- Department of Mechanical Engineering, The University of Western Ontario, London, ON, Canada; The Roth|McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada
| | - G Daniel G Langohr
- Department of Mechanical Engineering, The University of Western Ontario, London, ON, Canada; The Roth|McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada
| | - George S Athwal
- The Roth|McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada; Department of Surgery, The University of Western Ontario, London, ON, Canada
| | - James A Johnson
- Department of Mechanical Engineering, The University of Western Ontario, London, ON, Canada; The Roth|McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada; Department of Surgery, The University of Western Ontario, London, ON, Canada; Department of Biomedical Engineering, The University of Western Ontario, London, ON, Canada
| |
Collapse
|
20
|
Servin F, Collins JA, Heiselman JS, Frederick-Dyer KC, Planz VB, Geevarghese SK, Brown DB, Jarnagin WR, Miga MI. Simulation of Image-Guided Microwave Ablation Therapy Using a Digital Twin Computational Model. IEEE Open J Eng Med Biol 2023; 5:107-124. [PMID: 38445239 PMCID: PMC10914207 DOI: 10.1109/ojemb.2023.3345733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 08/14/2023] [Accepted: 12/04/2023] [Indexed: 03/07/2024] Open
Abstract
Emerging computational tools such as healthcare digital twin modeling are enabling the creation of patient-specific surgical planning, including microwave ablation to treat primary and secondary liver cancers. Healthcare digital twins (DTs) are anatomically one-to-one biophysical models constructed from structural, functional, and biomarker-based imaging data to simulate patient-specific therapies and guide clinical decision-making. In microwave ablation (MWA), tissue-specific factors including tissue perfusion, hepatic steatosis, and fibrosis affect therapeutic extent, but current thermal dosing guidelines do not account for these parameters. This study establishes an MR imaging framework to construct three-dimensional biophysical digital twins to predict ablation delivery in livers with 5 levels of fat content in the presence of a tumor. Four microwave antenna placement strategies were considered, and simulated microwave ablations were then performed using 915 MHz and 2450 MHz antennae in Tumor Naïve DTs (control), and Tumor Informed DTs at five grades of steatosis. Across the range of fatty liver steatosis grades, fat content was found to significantly increase ablation volumes by approximately 29-l42% in the Tumor Naïve and 55-60% in the Tumor Informed DTs in 915 MHz and 2450 MHz antenna simulations. The presence of tumor did not significantly affect ablation volumes within the same steatosis grade in 915 MHz simulations, but did significantly increase ablation volumes within mild-, moderate-, and high-fat steatosis grades in 2450 MHz simulations. An analysis of signed distance to agreement for placement strategies suggests that accounting for patient-specific tumor tissue properties significantly impacts ablation forecasting for the preoperative evaluation of ablation zone coverage.
Collapse
Affiliation(s)
- Frankangel Servin
- Department of Biomedical EngineeringVanderbilt UniversityNashvilleTN37235USA
- Vanderbilt Institute for Surgery and EngineeringVanderbilt UniversityNashvilleTN37235USA
| | - Jarrod A. Collins
- Department of Biomedical EngineeringVanderbilt UniversityNashvilleTN37235USA
| | - Jon S. Heiselman
- Department of Biomedical EngineeringVanderbilt UniversityNashvilleTN37235USA
- Vanderbilt Institute for Surgery and EngineeringVanderbilt UniversityNashvilleTN37235USA
- Department of Surgery, Hepatopancreatobiliary ServiceMemorial Sloan Kettering Cancer CenterNew YorkNY10065USA
| | | | - Virginia B. Planz
- Department of RadiologyVanderbilt University Medical CenterNashvilleTN37235USA
| | | | - Daniel B. Brown
- Department of RadiologyVanderbilt University Medical CenterNashvilleTN37235USA
| | - William R. Jarnagin
- Department of Surgery, Hepatopancreatobiliary ServiceMemorial Sloan Kettering Cancer CenterNew YorkNY10065USA
| | - Michael I. Miga
- Department of Biomedical EngineeringVanderbilt UniversityNashvilleTN37235USA
- Vanderbilt Institute for Surgery and EngineeringVanderbilt UniversityNashvilleTN37235USA
- Department of RadiologyVanderbilt University Medical CenterNashvilleTN37235USA
- Department of Neurological SurgeryVanderbilt University Medical CenterNashvilleTN37235USA
- Department of OtolaryngologyVanderbilt University Medical CenterNashvilleTN37235USA
| |
Collapse
|
21
|
Islam S, Gide K, Schemitsch EH, Bougherara H, Zdero R, Bagheri ZS. Biomechanical effects of different loads and constraints on finite element modeling of the humerus. Comput Methods Biomech Biomed Engin 2023:1-13. [PMID: 38151986 DOI: 10.1080/10255842.2023.2298371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 12/16/2023] [Indexed: 12/29/2023]
Abstract
Currently, there is no established finite element (FE) method to apply physiologically realistic loads and constraints to the humerus. This FE study showed that 2 'simple' methods involving direct head loads, no head constraints, and rigid elbow or mid-length constraints created excessive stresses and bending. However, 2 'intermediate' methods involving direct head loads, but flexible head and elbow constraints, produced lower stresses and bending. Also, 2 'complex' methods involving muscles to generate head loads, plus flexible head and elbow constraints, generated the lowest stresses and moderate bending. This has implications for FE modeling research on intact and implanted humeri.
Collapse
Affiliation(s)
- Sabrina Islam
- Department of Mechanical Engineering, George Mason University, Fairfax, VA, USA
| | - Kunal Gide
- Department of Mechanical Engineering, George Mason University, Fairfax, VA, USA
| | - Emil H Schemitsch
- Orthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada
- Division of Orthopaedic Surgery, Western University, London, ON, Canada
| | | | - Radovan Zdero
- Orthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada
| | - Z Shaghayegh Bagheri
- Department of Mechanical Engineering, George Mason University, Fairfax, VA, USA
- Toronto Rehabilitation Institute, University Health Network, Toronto, ON, Canada
| |
Collapse
|
22
|
Gómez-Gast N, Rivera-Santana JA, Otero JA, Vieyra H. Simulation of a Composite with a Polyhydroxybutyrate (PHB) Matrix Reinforced with Cylindrical Inclusions: Prediction of Mechanical Properties. Polymers (Basel) 2023; 15:4727. [PMID: 38139978 PMCID: PMC10747289 DOI: 10.3390/polym15244727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 11/30/2023] [Accepted: 12/02/2023] [Indexed: 12/24/2023] Open
Abstract
Biocomposite development, as a sustainable alternative to fossil-derived materials with diverse industrial applications, requires expediting the design process and reducing production costs. Simulation methods offer a solution to these challenges. The main aspects to consider in simulating composite materials successfully include accurately representing microstructure geometry, carefully selecting mesh elements, establishing appropriate boundary conditions representing system forces, utilizing an efficient numerical method to accelerate simulations, and incorporating statistical tools like experimental designs and re-regression models. This study proposes a comprehensive methodology encompassing these aspects. We present the simulation using a numerical homogenization technique based on FEM to analyze the mechanical behavior of a composite material of a polyhydroxybutyrate (PHB) biodegradable matrix reinforced with cylindrical inclusions of flax and kenab. Here, the representative volume element (RVE) considered the geometry, and the numerical homogenization method (NHM) calculated the macro-mechanical behavior of composites. The results were validated using the asymptotic homogenization method (AHM) and experimental data, with error estimations of 0.0019% and 7%, respectively. This model is valuable for predicting longitudinal and transverse elastic moduli, shear modulus, and Poisson's coefficient, emphasizing its significance in composite materials research.
Collapse
Affiliation(s)
- Natalia Gómez-Gast
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Carretera Lago de Guadalupe 3.5, Colonia Margarita Maza de Juárez, Atizapán de Zaragoza 52926, Mexico or (N.G.-G.); (J.A.O.)
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Eduardo Monroy Cárdenas 2000, San Antonio Buenavista, Toluca de Lerdo 50110, Mexico
| | - Juan Andrés Rivera-Santana
- Escuela de Ingeniería, Cetys Universidad, Campus Mexicali, Calzada Cetys, s/n, Colonia Rivera, Mexicali 21259, Mexico;
| | - José A. Otero
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Carretera Lago de Guadalupe 3.5, Colonia Margarita Maza de Juárez, Atizapán de Zaragoza 52926, Mexico or (N.G.-G.); (J.A.O.)
| | - Horacio Vieyra
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Eduardo Monroy Cárdenas 2000, San Antonio Buenavista, Toluca de Lerdo 50110, Mexico
| |
Collapse
|
23
|
Ahmad MM, Elahi A, Barbhuiya S. Comparative Analysis of Reinforced Concrete Beam Behaviour: Conventional Model vs. Artificial Neural Network Predictions. Materials (Basel) 2023; 16:7642. [PMID: 38138784 PMCID: PMC10744444 DOI: 10.3390/ma16247642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 11/23/2023] [Accepted: 11/24/2023] [Indexed: 12/24/2023]
Abstract
This research aims to conduct a comparative analysis of the first crack load, flexural strength, and shear strength in reinforced concrete beams without stirrups. The comparison is made between the conventional model developed according to the current design code (ACI building code) and an unconventional approach using Artificial Neural Networks (ANNs). To accomplish this, a dataset comprising 110 samples of reinforced concrete beams without stirrup reinforcement was collected and utilised to train a Multilayer Backpropagation Neural Network in MATLAB. The primary objective of this work is to establish a knowledge-based structural analysis model capable of accurately predicting the responses of reinforced concrete structures. The coefficient of determination obtained from this comparison yields values of 0.9404 for the first cracking load, 0.9756 for flexural strength, and 0.9787 for shear strength. Through an assessment of the coefficient of determination and linear regression coefficients, it becomes evident that the ANN model produces results that closely align with those obtained from the conventional model. This demonstrates the ANN's potential for precise prediction of the structural behaviour of reinforced concrete beams.
Collapse
Affiliation(s)
- Muhammad Mahtab Ahmad
- Civil Engineering Department, University of Engineering and Technology Taxila, Taxila 47050, Pakistan; (M.M.A.); (A.E.)
| | - Ayub Elahi
- Civil Engineering Department, University of Engineering and Technology Taxila, Taxila 47050, Pakistan; (M.M.A.); (A.E.)
| | - Salim Barbhuiya
- Department of Engineering and Construction, University of East London, London E16 2RD, UK
| |
Collapse
|
24
|
Mohammadgholipour A, Billah AHMM. Mechanical properties and constitutive models of shape memory alloy for structural engineering: A review. J Intell Mater Syst Struct 2023; 34:2335-2359. [PMID: 37970098 PMCID: PMC10638093 DOI: 10.1177/1045389x231185458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/17/2023]
Abstract
Shape Memory Alloys (SMAs) are an innovative material with the unique features of superelasticity and energy dissipation capabilities under extreme loads. Due to their unique features, they have a great potential to be employed in structural engineering applications under different conditions. However, in order to effectively use SMAs in civil engineering structures and model their behaviors accurately in Finite Element (FE) packages, it is crucial for structural engineers to comprehend the mechanical properties and cyclic behavior of different SMA compositions under varying loading conditions. While previous studies have focused mainly on the cyclic behavior of SMAs under tensile loading, it is important to evaluate their fatigue behavior under cyclic tension-compression loading for seismic applications. This literature review aims to discuss the current gaps in the existing literature on the behavior of SMA rebars under low-cycle fatigue (LCF). The review provides a comprehensive overview of the primary characteristics of SMAs, summarizes the mechanical properties of SMAs presented in the literature and the parameters that affect them, and critically evaluates the effects of cyclic loading and LCF on SMAs. The review also provides a summary of the different constitutive models of SMAs and compares their advantages and limitations, which helps structural engineers to employ an appropriate constitutive model for predicting the accurate behavior of SMAs in FE software.
Collapse
|
25
|
Zhang C, Guo LX. Prediction of the biomechanical behaviour of the lumbar spine under multi-axis whole-body vibration using a whole-body finite element model. Int J Numer Method Biomed Eng 2023; 39:e3764. [PMID: 37539646 DOI: 10.1002/cnm.3764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 07/17/2023] [Accepted: 07/21/2023] [Indexed: 08/05/2023]
Abstract
Low back pain has been reported to have a high prevalence among occupational drivers. Whole-body vibration during the driving environment has been found to be a possible factor leading to low back pain. Vibration loads might lead to degeneration and herniation of the intervertebral disc, which would increase incidence of low back problems among drivers. Some previous studies have reported the effects of whole-body vibration on the human body, but studies on the internal dynamic responses of the lumbar spine under multi-axis vibration are limited. In this study, the internal biomechanical response of the intervertebral disc was extracted to investigate the biomechanical behaviour of the lumbar spine under a multi-axial vibration in a whole-body environment. A whole-body finite element model, including skin, soft tissues, the bone skeleton, internal organs and a detailed ligamentous lumbar spine, was used to provide a whole-body condition for analyses. The results showed that both vibrations close to vertical and fore-and-aft resonance frequencies would increase the transmission of vibrations in the intervertebral disc, and vertical vibration might have a greater effect on the lumbar spine than fore-and-aft vibration. The larger deformation of the posterior region of the intervertebral disc in a multi-axis vibration environment might contribute to the higher susceptibility of the posterior region of the intervertebral disc to injury. The findings of this study revealed the dynamic behaviours of the lumbar spine in multi-axis vehicle vibration conditions, and suggested that both vertical and fore-and-aft vibration should be considered for protecting the lumbar health of occupational drivers.
Collapse
Affiliation(s)
- Chi Zhang
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang, China
| | - Li-Xin Guo
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang, China
| |
Collapse
|
26
|
Babcock CD, Volk VL, Zeng W, Hamilton LD, Shelburne KB, Fitzpatrick CK. Neural-driven activation of 3D muscle within a finite element framework: exploring applications in healthy and neurodegenerative simulations. Comput Methods Biomech Biomed Engin 2023:1-11. [PMID: 37966863 DOI: 10.1080/10255842.2023.2280772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Accepted: 11/02/2023] [Indexed: 11/16/2023]
Abstract
This paper presents a novel computational framework for neural-driven finite element muscle models, with an application to amyotrophic lateral sclerosis (ALS). The multiscale neuromusculoskeletal (NMS) model incorporates physiologically accurate motor neurons, 3D muscle geometry, and muscle fiber recruitment. It successfully predicts healthy muscle force and tendon elongation and demonstrates a progressive decline in muscle force due to ALS, dropping from 203 N (healthy) to 155 N (120 days after ALS onset). This approach represents a preliminary step towards developing integrated neural and musculoskeletal simulations to enhance our understanding of neurodegenerative and neurodevelopmental conditions through predictive NMS models.
Collapse
Affiliation(s)
- Colton D Babcock
- Mechanical and Biomedical Engineering, Boise State University, Boise, ID, USA
| | - Victoria L Volk
- Mechanical and Biomedical Engineering, Boise State University, Boise, ID, USA
| | - Wei Zeng
- Department of Mechanical Engineering, NY Institute of Technology, New York, NY, USA
| | - Landon D Hamilton
- Center for Orthopedic Biomechanics, University of Denver, Denver, CO, USA
| | - Kevin B Shelburne
- Center for Orthopedic Biomechanics, University of Denver, Denver, CO, USA
| | - Clare K Fitzpatrick
- Mechanical and Biomedical Engineering, Boise State University, Boise, ID, USA
| |
Collapse
|
27
|
Incze-Bartha Z, Incze-Bartha S, Simon Szabó Z, Feier AM, Vunvulea V, Nechifor-Boilă IA, Pastorello Y, Szasz D, Dénes L. Finite Element Analysis of Normal and Dysplastic Hip Joints in Children. J Pers Med 2023; 13:1593. [PMID: 38003908 PMCID: PMC10672490 DOI: 10.3390/jpm13111593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 11/07/2023] [Accepted: 11/08/2023] [Indexed: 11/26/2023] Open
Abstract
From a surgical point of view, quantification cannot always be achieved in the developmental deformity in hip joints, but finite element analysis can be a helpful tool to compare normal joint architecture with a dysplastic counterpart. CT scans from the normal right hip of an 8-year-old boy and the dysplastic left hip of a 12-year-old girl were used to construct our geometric models. In a three-dimensional model construction, distinctions were made between the cortical bone, trabecular bone, cartilage, and contact nonlinearities of the hip joint. The mathematical model incorporated the consideration of the linear elastic and isotropic properties of bony tissue in children, separately for the cortical bone, trabecular bone, and articular cartilage. Hexahedral elements were used in Autodesk Inventor software version 2022 ("Ren") for finite element analysis of the two hips in the boundary conditions of the single-leg stance. In the normal hip joint on the cartilaginous surfaces of the acetabulum, we found a kidney-shaped stress distribution in a 471,672 mm2 area. The measured contact pressure values were between 3.0 and 4.3 MPa. In the dysplastic pediatric hip joint on a patch of 205,272 mm2 contact area, the contact pressure values reached 8.5 MPa. Furthermore, the acetabulum/femur head volume ratio was 20% higher in the dysplastic hip joint. We believe that the knowledge gained from the normal and dysplastic pediatric hip joints can be used to develop surgical treatment methods and quantify and compare the efficiency of different surgical treatments used in children with hip dysplasia.
Collapse
Affiliation(s)
- Zsuzsánna Incze-Bartha
- Department of Anatomy, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania; (Z.I.-B.)
| | - Sandor Incze-Bartha
- Department of Orthopedics and Traumatology, “Fogolyan Kristof” County Hospital Sfantu Gheorghe, 520064 Covasna, Romania
| | - Zsuzsánna Simon Szabó
- Department of Anatomy, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania; (Z.I.-B.)
| | - Andrei Marian Feier
- Department of Orthopaedics and Traumatology, “George Emil Palade” University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540142 Targu Mures, Romania
| | - Vlad Vunvulea
- Department of Anatomy, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania; (Z.I.-B.)
| | - Ioan Alin Nechifor-Boilă
- Department of Anatomy, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania; (Z.I.-B.)
| | - Ylenia Pastorello
- Department of Anatomy, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania; (Z.I.-B.)
| | - Dezso Szasz
- Department of Orthopedics and Traumatology, “Fogolyan Kristof” County Hospital Sfantu Gheorghe, 520064 Covasna, Romania
| | - Lóránd Dénes
- Department of Anatomy, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania; (Z.I.-B.)
| |
Collapse
|
28
|
Huang Z, Song Y, Zhao X, Hou H. Piezoresistive Theory and Numerical Calculation for Carbon Nanotube Polymer Composite. Materials (Basel) 2023; 16:7090. [PMID: 38005020 PMCID: PMC10672310 DOI: 10.3390/ma16227090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 11/05/2023] [Accepted: 11/06/2023] [Indexed: 11/26/2023]
Abstract
A three-dimensional theory has been established for the piezoresistivity of carbon nanotube (CNT) polymer composites. Based on the Mori-Tanaka method in meso-mechanics theory and considering quantum tunneling effect between CNTs, an approach to calculate equivalent electrical conductivity of composites was proposed. On this basis, a piezoresistive theory, which incorporates the effect of composites' geometric nonlinearity, was developed for CNT polymer composites. The theory is dependent only on some basic physical parameters of the materials. A finite element formula of the theory for the numerical calculation of piezoresistivity was presented from the analysis of both elastic and electric fields. Numerical simulations demonstrated that the results predicted by the theory were in good agreement with those of the experimental tests. Parameter sensitivity analysis revealed that when both the potential barrier height of the matrix and the initial average separation distance between CNTs increased, the piezoresistivity obviously increased. However, with the increase in aspect ratio and CNT conductivity, the piezoresistivity decreased gradually. A practical engineering application of this theory is also provided.
Collapse
Affiliation(s)
- Zhengwei Huang
- Department of Civil and Environmental Engineering, Shantou University, Shantou 515063, China; (Z.H.); (Y.S.); (X.Z.)
- Key Laboratory of Structure and Wind Tunnel of Guangdong Higher Education Institutes, Shantou 515063, China
| | - Ying Song
- Department of Civil and Environmental Engineering, Shantou University, Shantou 515063, China; (Z.H.); (Y.S.); (X.Z.)
- Key Laboratory of Structure and Wind Tunnel of Guangdong Higher Education Institutes, Shantou 515063, China
| | - Xiaohua Zhao
- Department of Civil and Environmental Engineering, Shantou University, Shantou 515063, China; (Z.H.); (Y.S.); (X.Z.)
- Key Laboratory of Structure and Wind Tunnel of Guangdong Higher Education Institutes, Shantou 515063, China
| | - Huiming Hou
- Department of Civil and Environmental Engineering, Shantou University, Shantou 515063, China; (Z.H.); (Y.S.); (X.Z.)
- Key Laboratory of Structure and Wind Tunnel of Guangdong Higher Education Institutes, Shantou 515063, China
| |
Collapse
|
29
|
Kurtz T, Woitrain T, Godio-Raboutet Y, Ribeiro FLB, Arnoux PJ, Tailhan JL. Method for Evaluating Cortical Bone Young's Modulus: Numerical Twin Reconstruction, Finite Element Calculation, and Microstructure Analysis. J Biomech Eng 2023; 145:111013. [PMID: 37542711 DOI: 10.1115/1.4063100] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 07/17/2023] [Indexed: 08/07/2023]
Abstract
The determination of bone mechanical properties remains crucial, especially to feed up numerical models. An original methodology of inverse analysis has been developed to determine the longitudinal elastic modulus of femoral cortical bone. The method is based on a numerical twin of a specific three-point bending test. It has been designed to be reproducible on each test result. In addition, the biofidelity of the geometric acquisition method has been quantified. As the assessment is performed at the scale of a bone shaft segment, the Young's modulus values obtained (between 9518.29 MPa and 14181.15 MPa) are considered average values for the whole tissue, highlighting some intersubject variability. The material microstructure has also been studied through histological analysis, and bone-to-bone comparisons highlighted discrepancies in quadrants microstructures. Furthermore, significant intrasubject variability exists since differences between the bone's medial-lateral and anterior-posterior quadrants have been observed. Thus, the study of microstructures can largely explain the differences between the elastic modulus values obtained. However, a more in-depth study of bone mineral density would also be necessary and would provide some additional information. This study is currently being setup, alongside an investigation of the local variations of the elastic modulus.
Collapse
Affiliation(s)
- T Kurtz
- Aix Marseille Univ, Univ Gustave Eiffel, LBA, Marseille 13015, France
| | - T Woitrain
- Aix Marseille Univ, Univ Gustave Eiffel, LBA, Marseille 13015, France
| | - Y Godio-Raboutet
- Aix Marseille Univ, Univ Gustave Eiffel, LBA, Marseille 13015, France
| | - F L B Ribeiro
- Department of Civil Engineering, COPPE, Federal University of Rio de Janeiro, Centro de Tecnologia - Ilha do Fundao, Rio de Janeiro 21941, Brazil
| | - P-J Arnoux
- Aix Marseille Univ, Univ Gustave Eiffel, LBA, Marseille 13015, France
| | - J-L Tailhan
- Univ Gustave Eiffel, MAST-EMGCU, Marne la Vallée 77454, France
| |
Collapse
|
30
|
Li KH, Yang H, Li ZG, Ma XL. The effect of annulus fibrosus incision and foraminoplasty on lumbar biomechanics in percutaneous endoscopic lumbar discectomy: a finite element analysis. Comput Methods Biomech Biomed Engin 2023:1-9. [PMID: 37861409 DOI: 10.1080/10255842.2023.2271602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Accepted: 10/10/2023] [Indexed: 10/21/2023]
Abstract
The objective of this study was to analyze the effects of annulus fibrosus incision and foraminoplasty on lumbar biomechanics during posterior lateral approach translaminar percutaneous endoscopic lumbar discectomy (PELD) using a lumbar 4/5 segment model and three-dimensional finite element analysis (FEA). We created a model of the L4 to L5 segment and performed simulated foraminoplasty, annulus fibrosus incision, and a combined operation. The models were tested under six working conditions, and we recorded the deformation and equivalent strain/stress of each group. Results showed that foraminoplasty can affect the stability and rotation axis of the segment during rotation without significantly impacting discal stress. Conversely, annulus fibrosus incision significantly increases discal stress except for when the patient is doing a forward flexion movement. We recommend that surgical maneuvers minimize the removal and destruction of the annulus fibrosus and that rotation movements are avoided during the short-term recovery period following PELD surgery.
Collapse
Affiliation(s)
- Kai-Hua Li
- Graduate School of Tianjin Medical University, Tianjin, China
- Institute of Orthopedics, Fengfeng General Hospital of North China Medical& Health Group, Handan, Hebei, China
| | - Hui Yang
- Institute of Orthopedics, Fengfeng General Hospital of North China Medical& Health Group, Handan, Hebei, China
| | - Zhi-Guo Li
- Institute of Orthopedics, Fengfeng General Hospital of North China Medical& Health Group, Handan, Hebei, China
| | - Xin-Long Ma
- Department of Orthopedics, Tianjin Hospital, Tianjin, China
| |
Collapse
|
31
|
Abatta-Jacome L, Lima-Rodriguez A, Gonzalez-Herrera A, Garcia-Manrique JM. Numerical Study of the Plastic Zone at the Crack Front in Cylindrical Aluminum Specimens Subjected to Tensile Loads. Materials (Basel) 2023; 16:6759. [PMID: 37895742 PMCID: PMC10608569 DOI: 10.3390/ma16206759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 10/09/2023] [Accepted: 10/15/2023] [Indexed: 10/29/2023]
Abstract
Cylindrical specimens are of great interest in analyzing mechanical elements' behavior and investigating phenomena with biaxial loads. It is necessary to identify the behavior of the crack front along the thickness to interpret these results, which are usually based on the hypothesis of a straight crack and the observation of the outer face of the crack front. Based on the work carried out on compact tension type specimens, this work proposes adapting this methodology to cylindrical specimens, adapting the previous finite element models. Cylindrical specimens provide an asymmetric behavior influenced by the radius, where the CT (compact tensile) specimen can be considered the extreme infinite radius case. Combinations of the load level and radius values help us simulate the crack's behavior under intermediate hypotheses between a plane crack theory and a three-dimensional one. The plastic strain around the crack front will be analyzed as a function of the thickness and the load level applied. The results allow us to validate the numerical methodology and establish the differentiated behaviors of the plastic zones close to the outer and inner radii.
Collapse
Affiliation(s)
- Lenin Abatta-Jacome
- Department of Civil Engineering, Materials and Manufacturing, School of Engineering, University of Malaga, 29071 Málaga, Spain; (A.L.-R.); (A.G.-H.); (J.M.G.-M.)
- Department of Energy Sciences and Mechanics, University of the Armed Forces ESPE, Sangolquí 171103, Ecuador
| | - Antonia Lima-Rodriguez
- Department of Civil Engineering, Materials and Manufacturing, School of Engineering, University of Malaga, 29071 Málaga, Spain; (A.L.-R.); (A.G.-H.); (J.M.G.-M.)
| | - Antonio Gonzalez-Herrera
- Department of Civil Engineering, Materials and Manufacturing, School of Engineering, University of Malaga, 29071 Málaga, Spain; (A.L.-R.); (A.G.-H.); (J.M.G.-M.)
| | - Jose Manuel Garcia-Manrique
- Department of Civil Engineering, Materials and Manufacturing, School of Engineering, University of Malaga, 29071 Málaga, Spain; (A.L.-R.); (A.G.-H.); (J.M.G.-M.)
| |
Collapse
|
32
|
Liu Z, Wang C, Cheng J, Guo J. An Improved Grain Growth Model and Its Application in Gradient Heat Treatment of Aero-Engine Turbine Discs. Materials (Basel) 2023; 16:6584. [PMID: 37834720 PMCID: PMC10574442 DOI: 10.3390/ma16196584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 09/30/2023] [Accepted: 10/04/2023] [Indexed: 10/15/2023]
Abstract
A new grain growth model was developed by introducing the ultimate grain size to the traditional model. The grain growth behavior and its ultimate size under the Zenner pinning force are also discussed. This model was applied to the nickel-based superalloy and integrated into an FEM code. The grain evolution of a forged third-generation powder superalloy heat treated at different temperatures and holding times was studied. A gradient heat treatment setup was designed and implemented for a full-size turbine disc based on the model prediction to meet the accurate dual-microstructure requirements of an advanced aero-engine turbine disc design. The predicted temperature was validated by thermal couple measurements. The relative error between the prediction and the measurements is less than 2%. The metallographic examination of the whole turbine disk through sectioning showed that the grain size was ASTM 7-8 at the rim area and ASTM 11-12 at the bore region, which agrees well with the prediction. The predicted values of the three measurement areas are ASTM 12.1, ASTM 9.1, and ASTM 7.1, respectively, with a maximum error of 5% compared to the measured values. The proposed model was validated and successfully applied to help manufacture a dual-microstructure aero-engine turbine disc.
Collapse
Affiliation(s)
- Zhaofeng Liu
- State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, China; (Z.L.); (J.C.)
- Shenzhen Wedge Central South Research Institute Co., Ltd., Shenzhen 518035, China
| | - Chao Wang
- Shenzhen Wedge Central South Research Institute Co., Ltd., Shenzhen 518035, China
| | - Junyi Cheng
- State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, China; (Z.L.); (J.C.)
- Shenzhen Wedge Central South Research Institute Co., Ltd., Shenzhen 518035, China
| | - Jianzheng Guo
- State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, China; (Z.L.); (J.C.)
- Shenzhen Wedge Central South Research Institute Co., Ltd., Shenzhen 518035, China
| |
Collapse
|
33
|
Guo LX, Liu J. Topology optimization and dynamic characteristic evaluation of W-shaped interspinous process device. Comput Methods Biomech Biomed Engin 2023; 26:1610-1619. [PMID: 36200492 DOI: 10.1080/10255842.2022.2129968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 09/21/2022] [Accepted: 09/25/2022] [Indexed: 11/03/2022]
Abstract
For reducing the adjacent segment degeneration of the lumbar spine, the interspinous process device as a kind of flexible non-fusion device was designed to overcome the deficiencies associated with rigid fusion devices. However, it was not clear how the interspinous process device influenced the human spine system, especially the lumbar spine under a vibration environment. This study was designed to evaluate the effect of StenoFix under the vibration condition and also to optimize the structure of the device to obtain better biomechanical performance. A finite element model of the intact lumbar spine was developed and validated. The surgical finite element model was constructed by implanting the interspinous process device StenoFix. Using topology optimization, a new device StenoFix-new was redesigned. The results showed that the interspinous process device decreased vibration amplitudes of annulus stress and intradiscal pressure under vibration at the surgical level. The redesigned StenoFix-new with the smaller stiffness exhibited a better dynamic flexibility performance than StenoFix. In addition, the range of motions of StenoFix-new was closer to the intact model than StenoFix at the surgical level. These results might encourage the designers to give more consideration to the dynamic characteristics of the human spine on the premise of ensuring the safety and strength of implanted devices.
Collapse
Affiliation(s)
- Li-Xin Guo
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang, China
| | - Juan Liu
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang, China
| |
Collapse
|
34
|
Abstract
STUDY DESIGN Mechanical simulations. OBJECTIVE Inadequate calibration of annuli negatively affects the computational accuracy of finite element (FE) models. Specifically, the definition of annulus average radius (AR) does not have uniformity standards. Differences between the elastic moduli in the different layers and parts of the annulus were not fully calibrated when a linear elastic material is used to define its material properties. This study aims to optimize the computational accuracy of the FE model by calibrating the annulus. METHODS We calibrated the annulus AR and elastic modulus in our anterior-constructed lumbar model by eliminating the difference between the computed range of motion and that measured by in vitro studies under a flexion-extension loading condition. Multi-indicator validation was performed by comparing the computed indicators with those measured in in vitro studies. The computation time required for the different models has also been recorded to evaluate the computational efficiency. RESULTS The difference between computed and measured ROMs was less than 1% when the annulus AR and elastic modulus were calibrated. In the model validation process, all the indicators computed by the calibrated FE model were within ±1 standard deviation of the average values obtained from in vitro studies. The maximum difference between the computed and measured values was less than 10% under nearly all loading conditions. There is no apparent variation tendency for the computational time associated with different models. CONCLUSION The FE model with calibrated annulus AR and regional elastic modulus has higher computational accuracy and can be used in subsequent mechanical studies.
Collapse
Affiliation(s)
- Chen Xu
- Department of Spine Surgery, Shanghai Changzheng Hospital, Naval Medical University, Shanghai, China
| | - Zhipeng Xi
- Department of Orthopedics, Jiangsu Province Hospital on Integration of Chinese and Western Medicine, Nanjing, China
| | - Zhongxin Fang
- Fluid and Power Machinery Key Laboratory of Ministry of Education, Xihua University, Chengdu, China
| | - Xiaoyu Zhang
- Department of Orthopedics, Jiangsu Province Hospital on Integration of Chinese and Western Medicine, Nanjing, China
| | - Nan Wang
- Department of Orthopedics, Jiangsu Province Hospital on Integration of Chinese and Western Medicine, Nanjing, China
| | - Jingchi Li
- Department of Spine Surgery, Shanghai Changzheng Hospital, Naval Medical University, Shanghai, China
- Department of Orthopedics, Hospital (T.C.M) Affiliated to Southwest Medical University, Luzhou, China
| | - Yang Liu
- Department of Spine Surgery, Shanghai Changzheng Hospital, Naval Medical University, Shanghai, China
| |
Collapse
|
35
|
Nassar M, Amleh L. Transient Thermal Analysis of Concrete Box Girders: Assessing Temperature Variations in Canadian Climate Zones. Sensors (Basel) 2023; 23:8206. [PMID: 37837035 PMCID: PMC10575200 DOI: 10.3390/s23198206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 09/22/2023] [Accepted: 09/27/2023] [Indexed: 10/15/2023]
Abstract
This study examines the temperature distributions and thermal-induced responses in reinforced concrete bridge elements, focusing on the Canadian climate regions. The Canadian Highway Bridge Design Code (CHBDC) currently utilizes a fixed thermal gradient profile that does not account for regional climatic variations. Historical environmental data determines the effective maximum temperatures in the CHBDC. In order to investigate temperature behaviors and distributions, a transient finite element (FE) model is developed using recorded and calculated 3-month thermal loads data for representative cities in different climate regions. The results indicate that the predicted daily maximum effective mean temperatures and extreme daily positive vertical thermal gradients do not align. A linear correlation exists between the daily maximum effective mean temperature and the daily maximum air temperature, with a coefficient of determination (R2) of 0.935. The proposed effective mean temperatures obtained from the FE thermal analysis are higher than the CHBDC recommendations. New thermal gradient profiles are proposed for Canadian climate zones, consisting of two straight lines and a linear gradient at the top and bottom sections. A comparison between the proposed profiles and the CHBDC and AASHTO specifications reveals that a single fixed thermal gradient profile is inadequate to account for the variation in thermal gradients across Canadian climate regions.
Collapse
Affiliation(s)
| | - Lamya Amleh
- Civil Engineering Department, Toronto Metropolitan University, Toronto, ON M4B 2K3, Canada;
| |
Collapse
|
36
|
Robles Poblete F, Ireland M, Slattery L, Davids WG, Lopez-Anido RA. In Situ, Real-Time Temperature Mapping and Thermal FE Simulations of Large-Format 3D Printed PETG/CF Vertical Wall. Materials (Basel) 2023; 16:6486. [PMID: 37834624 PMCID: PMC10573507 DOI: 10.3390/ma16196486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 08/31/2023] [Accepted: 09/04/2023] [Indexed: 10/15/2023]
Abstract
This work focuses on simulating the thermal history of a vertical wall consisting of a thermoplastic composite material, poly(ethylene terephthalate) glycol (PETG) with short carbon fiber reinforcement, manufactured using a Big Area Additive Manufacturing (BAAM) system. The incremental deposition process used in additive manufacturing, which corresponds to the repeated deposition of hot material onto cooler material, contributes to the presence of residual stresses and part warping. The prediction of these mechanisms is dependent on thermal history of the part, and the major motivation of this work was to improve the accuracy of finite element (FE) models used to quantify the thermal history of large-format additively manufactured parts. Thermocouples were placed throughout the part at varying heights to measure temperature as a function of time. The FE model developed found a thermal contact conductance between the printed part and the bed of 10 W/m2K and convection coefficient values that linearly varied from 3 to 15 W/m2K through the wall height when making a temperature comparison with the output from the thermocouples. It is also demonstrated that the FE model with a constant convection coefficient under-predicts model temperature at the beginning of the manufacturing process when compared against the model with a variable convection coefficient. The impact of this difference was seen in the stress values, which were larger for the model with a constant convection coefficient. Finally, a correlation equation was derived which allows the findings to be generalized to other vertical structures manufactured on the BAAM. In summary, this work offers valuable insights on material characterization, real-time thermocouple placement, and FE modeling of large-format additively manufactured parts.
Collapse
Affiliation(s)
- Felipe Robles Poblete
- Advanced Structures and Composites Center (ASCC), University of Maine, Orono, ME 04469, USA; (F.R.P.); (M.I.)
| | - Matthew Ireland
- Advanced Structures and Composites Center (ASCC), University of Maine, Orono, ME 04469, USA; (F.R.P.); (M.I.)
| | - Lucinda Slattery
- Department of Physics and Astronomy, University of Maine, Orono, ME 04469, USA;
| | - William G. Davids
- Department of Civil and Environmental Engineering, University of Maine, Orono, ME 04469, USA;
| | - Roberto A. Lopez-Anido
- Department of Civil and Environmental Engineering, University of Maine, Orono, ME 04469, USA;
| |
Collapse
|
37
|
Lin M, Doulgeris J, Dhar UK, O’Corner T, Papanastassiou ID, Tsai CT, Vrionis FD. Effect of graded posterior element and ligament removal on annulus stress and segmental stability in lumbar spine stenosis: a finite element analysis study. Front Bioeng Biotechnol 2023; 11:1237702. [PMID: 37790254 PMCID: PMC10543754 DOI: 10.3389/fbioe.2023.1237702] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 08/30/2023] [Indexed: 10/05/2023] Open
Abstract
The study aimed to investigate the impact of posterior element and ligament removal on the maximum von Mises stress, and maximum shear stress of the eight-layer annulus for treating stenosis at the L3-L4 and L4-L5 levels in the lumbar spine. Previous studies have indicated that laminectomy alone can result in segmental instability unless fusion is performed. However, no direct correlations have been established regarding the impact of posterior and ligament removal. To address this gap, four models were developed: Model 1 represented the intact L2-L5 model, while model 2 involved a unilateral laminotomy involving the removal of a section of the L4 inferior lamina and 50% of the ligament flavum between L4 and L5. Model 3 consisted of a complete laminectomy, which included the removal of the spinous process and lamina of L4, as well as the relevant connecting ligaments between L3-L4 and L4-L5 (ligament flavum, interspinous ligament, supraspinous ligament). In the fourth model, a complete laminectomy with 50% facetectomy was conducted. This involved the same removals as in model 3, along with a 50% removal of the inferior/superior facets of L4 and a 50% removal of the facet capsular ligaments between L3-L4 and L4-L5. The results indicated a significant change in the range of motion (ROM) at the L3-L4 and L4-L5 levels during flexion and torque situations, but no significant change during extension and bending simulation. The ROM increased by 10% from model 1 and 2 to model 3, and by 20% to model 4 during flexion simulation. The maximum shear stress and maximum von-Mises stress of the annulus and nucleus at the L3-L4 levels exhibited the greatest increase during flexion. In all eight layers of the annulus, there was an observed increase in both the maximum shear stress and maximum von-Mises stress from model 1&2 to model 3 and model 4, with the highest rate of increase noted in layers 7&8. These findings suggest that graded posterior element and ligament removal have a notable impact on stress distribution and range of motion in the lumbar spine, particularly during flexion.
Collapse
Affiliation(s)
- Maohua Lin
- Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, FL, United States
| | - James Doulgeris
- Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, FL, United States
| | - Utpal Kanti Dhar
- Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, FL, United States
| | - Timothy O’Corner
- Department of Neurosurgery, Marcus Neuroscience Institute, Boca Raton Regional Hospital, Boca Raton, FL, United States
| | | | - Chi-Tay Tsai
- Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, FL, United States
| | - Frank D. Vrionis
- Department of Neurosurgery, Marcus Neuroscience Institute, Boca Raton Regional Hospital, Boca Raton, FL, United States
| |
Collapse
|
38
|
Wang Y, Jiang H, Teo EC, Gu Y. Finite Element Analysis of Head-Neck Kinematics in Rear-End Impact Conditions with Headrest. Bioengineering (Basel) 2023; 10:1059. [PMID: 37760161 PMCID: PMC10525499 DOI: 10.3390/bioengineering10091059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 08/24/2023] [Accepted: 09/01/2023] [Indexed: 09/29/2023] Open
Abstract
A detailed three-dimensional (3D) head-neck (C0-C7) finite element (FE) model was developed and used to dictate the motions of each cervical spinal segment under static physiological loadings of flexion and extension with a magnitude of 1.0 Nm and rear-end impacts. In this dynamic study, a rear-end impact pulse was applied to C7 to create accelerations of 4.5 G and 8.5 G. The predicted segmental motions and displacements of the head were in agreement with published results under physiological loads of 1.0 Nm. Under rear-end impact conditions, the effects of peak pulse acceleration and headrest angles on the kinematic responses of the head-neck complex showed rates of increase/decrease in the rotational motion of various cervical spinal segments that were different in the first 200 ms. The peak flexion rotation of all segments was lower than the combined ROM of flexion and extension. The peak extension rotation of all segments showed variation compared to the combined ROM of flexion and extension depending on G and the headrest angle. A higher acceleration of C7 increased the peak extension angle of lower levels, but the absolute increase was restricted by the distance between the head and the headrest. A change in the headrest angle from 45° to 30° resulted in a change in extension rotation at the lower C5-C6 segments to flexion rotation, which further justified the effectiveness of having distance between the head and the headrest. This study shows that the existing C0-C7 FE model is efficient at defining the gross reactions of the human cervical spine under both physiological static and simulated whiplash circumstances. The fast rate of changes in flexion and extension rotation of various segments may result in associated soft tissues and bony structures experiencing tolerances beyond their material characteristic limits. It is suggested that a proper location and angle of the headrest could effectively prevent the cervical spine from injury in traumatic vehicular accidents.
Collapse
Affiliation(s)
- Yuan Wang
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China; (H.J.); (Y.G.)
- Research Academy of Grand Health, Ningbo University, Ningbo 315211, China
| | - Hanhui Jiang
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China; (H.J.); (Y.G.)
- Research Academy of Grand Health, Ningbo University, Ningbo 315211, China
| | - Ee Chon Teo
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China; (H.J.); (Y.G.)
- Research Academy of Grand Health, Ningbo University, Ningbo 315211, China
| | - Yaodong Gu
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China; (H.J.); (Y.G.)
- Research Academy of Grand Health, Ningbo University, Ningbo 315211, China
| |
Collapse
|
39
|
Pradhan VV, Ramachandra R, Stammen J, Kracht C, Moorhouse K, Bolte JH, Kang YS. Biofidelity assessment of the GHBMC M50-O in a rear-facing seat configuration during high-speed frontal impact. Comput Methods Biomech Biomed Engin 2023:1-16. [PMID: 37680130 DOI: 10.1080/10255842.2023.2239417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 07/12/2023] [Indexed: 09/09/2023]
Abstract
The objective of this study was to assess the biofidelity of the Global Human Body Models Consortium (GHBMC) 50th male (M50-O) v6.0 seated in an upright (25-degree recline) all-belts-to-seat (ABTS) in a 56 km/h rear-facing frontal impact. The experimental boundary conditions from the post-mortem human subjects (PMHS) tests were replicated in the computational finite element (FE) environment. The performance of the rigidized FE ABTS model obtained from the original equipment manufacturer was validated via simulations using a Hybrid III FE model and comparison with experiments. Biofidelity of the GHBMC M50-O was evaluated using the most updated NHTSA Biofidelity Ranking System (BRS) method, where a biofidelity score under 2 indicates that the GHBMC response varies from the mean PMHS response by less than two standard deviations, suggesting good biofidelity. The GHBMC M50-O received an occupant response score and a seat loading score of 1.71 and 1.44, respectively. Head (BRS = 0.93) and pelvis (BRS = 1.29) resultant accelerations, and T-spine (avg. BRS = 1.55) and pelvis (BRS = 1.66) y-angular velocities were similar to the PMHS. The T-spine resultant accelerations (avg. BRS = 1.93) and head (BRS = 2.82), T1 (BRS = 2.10) and pelvis (BRS = 2.10) Z-displacements were underestimated in the GHBMC. Peak chest deflection in the anterior-posterior deflection in the GHBMC matched with the PMHS mean, however, the relative upward motion of abdominal contents and subsequent chest expansion were not observed in the GHBMC. Updates to the GHBMC M50-O towards improved thorax kinematics and mobility of abdominal organs should be considered to replicate PMHS characteristics more closely.
Collapse
Affiliation(s)
- Vikram V Pradhan
- Injury Biomechanics Research Center, The Ohio State University, Columbus, Ohio, USA
| | | | - Jason Stammen
- National Highway Traffic Safety Administration, Vehicle Research and Test Center, East Liberty, Ohio, USA
| | - Corey Kracht
- Production Engineering Department, TS Tech Americas, Inc, Reynoldsburg, Ohio, USA
| | - Kevin Moorhouse
- National Highway Traffic Safety Administration, Vehicle Research and Test Center, East Liberty, Ohio, USA
| | - John H Bolte
- Injury Biomechanics Research Center, The Ohio State University, Columbus, Ohio, USA
| | - Yun-Seok Kang
- Injury Biomechanics Research Center, The Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
40
|
Gao L, Cai C, Li C, Mak CM. Numerical Analysis of the Mitigation Performance of a Buried PT-WIB on Environmental Vibration. Sensors (Basel) 2023; 23:7666. [PMID: 37765723 PMCID: PMC10536162 DOI: 10.3390/s23187666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 09/04/2023] [Accepted: 09/04/2023] [Indexed: 09/29/2023]
Abstract
Environmental vibration pollution has serious negative impacts on human health. Among the various contributors to environmental vibration pollution in urban areas, rail transit vibration stands out as a significant source. Consequently, addressing this issue and finding effective measures to attenuate rail transit vibration has become a significant area of concern. An infilled trench can be arranged periodically along the propagation paths of the waves in the soil to attenuate vibration waves in a specific frequency range. However, the periodic infilled trench seems to be unsatisfactory for providing wide band gaps at low and medium frequencies. To improve the isolation performance of wave barriers at low to medium frequencies, a buried PT-WIB consisting of a periodic infilled trench and a wave impedance block barrier has been proposed in this paper. A three-dimensional finite element model has been developed to evaluate the isolation performance of three wave barriers. The influence of the PT-WIB's parameters on isolation performance has been analyzed. The results indicate that the combined properties of the periodic structure and the wave impedance block barrier can effectively achieve a wide attenuation zone at low and medium frequencies, enhancing the isolation performance for mitigating environmental vibration pollution.
Collapse
Affiliation(s)
- Lei Gao
- School of Civil Engineering, Central South University, Changsha 410000, China
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - Chenzhi Cai
- School of Civil Engineering, Central South University, Changsha 410000, China
| | - Chao Li
- School of Civil Engineering, Central South University, Changsha 410000, China
| | - Cheuk Ming Mak
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong
| |
Collapse
|
41
|
Dong R, Tang S, Cheng X, Wang Z, Zhang P, Wei Z. Influence of foot excitation and shin posture on the vibration behavior of the entire spine inside a seated human body. Comput Methods Biomech Biomed Engin 2023:1-16. [PMID: 37668064 DOI: 10.1080/10255842.2023.2252956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 07/28/2023] [Accepted: 08/17/2023] [Indexed: 09/06/2023]
Abstract
Due to ethical issues and simplification of traditional biomechanical models, experimental methods and traditional computer methods were difficult to quantify the effects of foot excitation and shin posture on vibration behavior of the entire spine inside a seated human body under vertical whole-body vibration. This study developed and verified different three-dimensional (3D) finite element (FE) models of seated human body with detailed anatomical structure under the biomechanical characteristics to predict vibration behavior of the entire spine inside a seated human body with different foot excitation (with and without vibration) and shin posture (vertical and tilt posture). Random response analysis was performed to study the transmissibility of the entire spine to seat under vertical white noise excitation between 0 and 20 Hz at 0.5 m/s2 r.m.s. The results showed that although the foot excitation could reduce the fore-aft transmissibility in the cervical spine (23% reduction), it could significantly increase that in the lumbar spine (52% increase), which resulted in complex alternating stresses at lumbar spine and made the lumbar spine more vulnerable to injury in long-term vibration environment. Moreover, the shin tilt posture made the maximum fore-aft transmissibility in the lumbar spine move to the upper lumbar spine. The study provided new insights into the influence of foot excitation and shin posture on the vibration behavior of the entire spine inside a seated human body. Foot excitation exposed the lumbar spine to complex alternating stresses and made it more vulnerable to injury in long-term whole body vibration.
Collapse
Affiliation(s)
- RuiChun Dong
- School of Mechanical Engineering, Shandong University of Technology, Zibo, P.R. China
| | - ShengJie Tang
- School of Mechanical Engineering, Shandong University of Technology, Zibo, P.R. China
| | - Xiang Cheng
- School of Mechanical Engineering, Shandong University of Technology, Zibo, P.R. China
| | - ZongLiang Wang
- Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, P.R. China
| | - PeiBiao Zhang
- Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, P.R. China
| | - Zheng Wei
- School of Mechanical Engineering, Shandong University of Technology, Zibo, P.R. China
| |
Collapse
|
42
|
Berti F, Petrini L. The impact of modeling choices on the assessment of Ni-Ti fatigue properties through surrogate specimens. Int J Numer Method Biomed Eng 2023; 39:e3753. [PMID: 37424171 DOI: 10.1002/cnm.3753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 05/19/2023] [Accepted: 06/25/2023] [Indexed: 07/11/2023]
Abstract
The implant of self-expandable Ni-Ti stents for the treatment of peripheral diseases has become an established medical practice. However, the reported failure in clinics highlights the open issue of the fatigue characterization of these devices. One of the most common approaches for calculating the Ni-Ti fatigue limit (commonly defined in terms of mean and alternate strain for a fixed number of cycles) consists of using surrogate specimens which replicate the strain distributions of the final device but in simplified geometries. The main drawback lies in the need for computational models to determine the local distribution and, hence, interpret the experimental results. This study aims at investigating the role of different choices in the model preparation, such as the mesh refinement and the element formulation, on the output of the fatigue analysis. The analyses show a strong dependency of the numerical results on modeling choices. The use of linear reduced elements enriched by a layer of membrane elements is successful to increase the accuracy of the results, especially when coarser meshes are used. Due to material nonlinearity and stent complex geometries, for the same loading conditions and element type, (i) different meshes result in different couples of mean and amplitude strains and (ii) for the same mesh, the position of the maximum mean strain is not coincident with the maximum amplitude, making difficult the selection of the limit values.
Collapse
Affiliation(s)
- Francesca Berti
- LaBS-Department of Chemistry, Materials and Chemical Engineering "G. Natta", Politecnico di Milano, Milan, Italy
| | - Lorenza Petrini
- Department of Civil and Environmental Engineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
43
|
Han H, Guo B, Gao P, Yang F, Sun C, Hill NA, Liu H. Finite-element simulation of in-plane tear propagation in the dissected aorta: Implications for the propagation mechanism. Int J Numer Method Biomed Eng 2023; 39:e3743. [PMID: 37344920 PMCID: PMC10909461 DOI: 10.1002/cnm.3743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 04/25/2023] [Accepted: 06/01/2023] [Indexed: 06/23/2023]
Abstract
Computer modeling and numerical simulation are essential for understanding the progression of aortic dissection. However, tear propagation has not been properly modeled and simulated. The in-plane dissection propagation between concentrically distributed elastic lamellae is modeled using the cohesive zone method with a bilinear traction-separation law. The parameters of cohesive elements are calibrated for the three modes of interfacial damage in the media, enabling quantitative predictions of in-plane tear propagation. An idealized cylindrical tube-shaped bilayer thick-wall model of the aorta is employed to elucidate the influence of geometrical parameters, loading conditions and residual stress on the tear propagation. While the model is capable of replicating that deeper, larger tears are associated with lower critical pressure, new findings include: (i) Larger axial stretch leads to lower critical pressure; (ii) Increased magnitude of residual stress is associated with higher critical pressure; (iii) Pressure difference between true and false lumen alters the critical pressure; (iv) The interfacial damage is mostly opening mode in the axial direction, but shear-dominated in the circumferential direction; (v) Damage due to the opening mode is associated with smaller fracture energy, which makes it easier to propagate than the shear and the mixed modes. (vi) The deformed shape of the tear, which is related to its geometrical features and loading conditions, modulates the critical pressure via two pathways: (a) deformed shapes are associated with specific modes of damage, which influences the critical pressure, and (b) deformed shapes modulate the critical pressure directly via geometrical constraints.
Collapse
Affiliation(s)
- Han Han
- Department of MechanicsTianjin UniversityTianjinChina
| | - Baolei Guo
- Department of Vascular SurgeryZhongshan Hospital, Fudan UniversityShanghaiChina
| | - Peng Gao
- Department of MechanicsTianjin UniversityTianjinChina
| | - Fan Yang
- Department of MechanicsTianjin UniversityTianjinChina
| | - Cuiru Sun
- Department of MechanicsTianjin UniversityTianjinChina
| | - Nicholas A. Hill
- School of Mathematics and StatisticsUniversity of GlasgowGlasgowUK
| | - Haofei Liu
- Department of MechanicsTianjin UniversityTianjinChina
| |
Collapse
|
44
|
Zhao L, Liu T, Li X, Cui Q, Wang X, Song K, Ge D, Li W. Study of Finite Element Simulation on the Mechano-Bactericidal Mechanism of Hierarchical Nanostructure Arrays. ACS Biomater Sci Eng 2023; 9:4770-4780. [PMID: 37503882 DOI: 10.1021/acsbiomaterials.3c00633] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/29/2023]
Abstract
Biomimetic nanostructures with bactericidal performance have become the research focus in constructing sterilization surfaces, but the mechano-bactericidal mechanism is still not fully understood, especially for the hierarchical nanostructure arrays with different heights. Herein, the interaction between Escherichia coli cells and nanostructure arrays was simulated by finite element, and the initial rupture points, i.e., critical action sites, of bacterial cells and the effects of nanostructure geometries on the cell rupture speed were analyzed based on the mechano-response of Escherichia coli cells on flat (identical heights) and hierarchical nanostructure arrays. The critical action sites of bacterial cells on nanostructure arrays are all at the three-phase junction zone of cell-liquid-nanostructure, but they are slightly shifted by the height difference ΔH of nanostructures on hierarchical nanopillar (NP)/nanosheet (NS) arrays, where the NP is higher than the NS. When ΔH < 20 nm, the site nears the NS corners, and when ΔH ≥ 20 nm, the site is consistent with that of the NP/NP array, i.e., the site locates at the three-phase junction zone of cell-liquid-high NP. In addition, except for decreasing the NP diameter, the NS thickness/width, or properly increasing the nanostructure spacing, the cell rupture can be accelerated via increasing the ΔH of nanostructures. ΔH = 40 nm is distinguished as the boundary for the effect of nanostructure ΔH on the cell rupture speed. When ΔH < 40 nm, the cell rupture speed rapidly increases as the ΔH increases; when ΔH ≥ 40 nm, the cell rupture speed reaches the maximum value and remains stable. This study provides a new strategy on how to design high-efficiency bactericidal surfaces.
Collapse
Affiliation(s)
- Lidan Zhao
- School of Chemical Engineering, Dalian University of Technology, Dalian 116024, Liaoning, P. R. China
- School of Life Science and Technology, Weifang Medical University, Weifang 261053, Shandong, P. R. China
| | - Tianqing Liu
- School of Chemical Engineering, Dalian University of Technology, Dalian 116024, Liaoning, P. R. China
| | - Xiangqin Li
- School of Chemical Engineering, Dalian University of Technology, Dalian 116024, Liaoning, P. R. China
| | - Qianqian Cui
- School of Chemical Engineering, Dalian University of Technology, Dalian 116024, Liaoning, P. R. China
| | - Xin Wang
- School of Chemical Engineering, Dalian University of Technology, Dalian 116024, Liaoning, P. R. China
| | - Kedong Song
- School of Chemical Engineering, Dalian University of Technology, Dalian 116024, Liaoning, P. R. China
| | - Dan Ge
- School of Chemical Engineering, Dalian University of Technology, Dalian 116024, Liaoning, P. R. China
| | - Wenfang Li
- School of Life Science and Technology, Weifang Medical University, Weifang 261053, Shandong, P. R. China
| |
Collapse
|
45
|
Cheng ESW, Lai DKH, Mao YJ, Lee TTY, Lam WK, Cheung JCW, Wong DWC. Computational Biomechanics of Sleep: A Systematic Mapping Review. Bioengineering (Basel) 2023; 10:917. [PMID: 37627802 PMCID: PMC10451553 DOI: 10.3390/bioengineering10080917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/24/2023] [Accepted: 07/31/2023] [Indexed: 08/27/2023] Open
Abstract
Biomechanical studies play an important role in understanding the pathophysiology of sleep disorders and providing insights to maintain sleep health. Computational methods facilitate a versatile platform to analyze various biomechanical factors in silico, which would otherwise be difficult through in vivo experiments. The objective of this review is to examine and map the applications of computational biomechanics to sleep-related research topics, including sleep medicine and sleep ergonomics. A systematic search was conducted on PubMed, Scopus, and Web of Science. Research gaps were identified through data synthesis on variants, outcomes, and highlighted features, as well as evidence maps on basic modeling considerations and modeling components of the eligible studies. Twenty-seven studies (n = 27) were categorized into sleep ergonomics (n = 2 on pillow; n = 3 on mattress), sleep-related breathing disorders (n = 19 on obstructive sleep apnea), and sleep-related movement disorders (n = 3 on sleep bruxism). The effects of pillow height and mattress stiffness on spinal curvature were explored. Stress on the temporomandibular joint, and therefore its disorder, was the primary focus of investigations on sleep bruxism. Using finite element morphometry and fluid-structure interaction, studies on obstructive sleep apnea investigated the effects of anatomical variations, muscle activation of the tongue and soft palate, and gravitational direction on the collapse and blockade of the upper airway, in addition to the airflow pressure distribution. Model validation has been one of the greatest hurdles, while single-subject design and surrogate techniques have led to concerns about external validity. Future research might endeavor to reconstruct patient-specific models with patient-specific loading profiles in a larger cohort. Studies on sleep ergonomics research may pave the way for determining ideal spine curvature, in addition to simulating side-lying sleep postures. Sleep bruxism studies may analyze the accumulated dental damage and wear. Research on OSA treatments using computational approaches warrants further investigation.
Collapse
Affiliation(s)
- Ethan Shiu-Wang Cheng
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
- Department of Electronic and Information Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - Derek Ka-Hei Lai
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - Ye-Jiao Mao
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - Timothy Tin-Yan Lee
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - Wing-Kai Lam
- Sports Information and External Affairs Centre, Hong Kong Sports Institute, Hong Kong
| | - James Chung-Wai Cheung
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
- Research Institute for Sports Science and Technology, The Hong Kong Polytechnic University, Hong Kong
| | - Duo Wai-Chi Wong
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
- Research Institute for Sports Science and Technology, The Hong Kong Polytechnic University, Hong Kong
| |
Collapse
|
46
|
Yang P, Liu Q, Lin T, Aikebaier A, Jiang L, Sun W, Zhang Q, Bai X, Sun W. Mechanical upside of PAO mainstream fixations: co-simulation based on early postoperative gait characteristics of DDH patients. Front Bioeng Biotechnol 2023; 11:1171040. [PMID: 37539435 PMCID: PMC10396769 DOI: 10.3389/fbioe.2023.1171040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 07/03/2023] [Indexed: 08/05/2023] Open
Abstract
Purpose: To investigate the early postoperative gait characteristics of patients who underwent periacetabular osteotomy (PAO) and predict the biomechanical performance of two commonly used PAO fixation methods: iliac screw (IS) and transverse screw (TS). Methods: A total of 12 patients with unilateral developmental dysplasia of the hip (DDH) (mean age 27.81 ± 4.64 years, 42% male) that were scheduled to undergo PAO surgery were included in this study. Their preoperative CT images and pre- and postoperative gait data were used to create subject-specific musculoskeletal models and complete the inverse dynamics analysis (IDA). Two patients with typical gait characteristics were selected using clustering analysis, and their IDA data were incorporated into finite element (FE) models of IS and TS fixations. Failure simulation was performed by applying iterative steps with increasing gait load to predict yield load. Stress results and yield loads were calculated for each FE model at different phases of the gait cycle. Results: Postoperative gait showed improvement compared to preoperative gait but remained inferior to that of healthy individuals. Postoperative gait was characterized by a lower hip range of motion, lower peri-ilium muscle forces, particularly in the abductors, and a sharper initial peak and flatter second peak of hip joint reaction force (HRF). Finite element analysis (FEA) showed a trend of increasing stress during the second-fourth phases of the gait cycle, with lower stress levels in other phases. At high-stress gait phases, the mean stress of maximum p ¯ 100 differed significantly between IS and TS (p < 0.05) and between coupled and uncoupled muscle forces (p < 0.05). Failure analysis predicted a slightly larger yield load for TS configurations (6.21*BW) than that for IS (6.16*BW), but both were well above the gait load. Coupled and uncoupled groups showed similar results, but uncoupled groups had lower yield loads (5.9*BW). Conclusion: PAO early postoperative gait shows a normalized trend, but abnormalities persist. IS and TS are both capable of resisting mechanical strain failure, with no significant mechanical advantage found for transverse screw fixation during PAO early postoperative gait. Additionally, it is important to note that the TS may have a higher risk of cyclic fatigue failure due to the localized greater stress concentration. Furthermore, the most medial screw is crucial for pelvic stability.
Collapse
Affiliation(s)
- Peng Yang
- Department of Orthopedics, Shenzhen Second People’s Hospital, Shenzhen, Guangdong, China
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences (CAS), Shenzhen, Guangdong, China
| | - Qi Liu
- Department of Orthopedics, Shenzhen Second People’s Hospital, Shenzhen, Guangdong, China
| | - Tianye Lin
- Traumatology and Orthopedics Institute of Chinese Medicine of Guangdong, Guangzhou, Guangdong, China
| | - Aobulikasimu Aikebaier
- Department of Orthopedics, Shenzhen Second People’s Hospital, Shenzhen, Guangdong, China
| | - Luoyong Jiang
- Department of Orthopedics, Shenzhen Second People’s Hospital, Shenzhen, Guangdong, China
| | - Weichao Sun
- Department of Orthopedics, Shenzhen Second People’s Hospital, Shenzhen, Guangdong, China
| | - Qingwen Zhang
- Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, Guangdong, China
| | - Xueling Bai
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences (CAS), Shenzhen, Guangdong, China
| | - Wei Sun
- Department of Orthopedics, Shenzhen Second People’s Hospital, Shenzhen, Guangdong, China
| |
Collapse
|
47
|
Emendi M, Støverud KH, Tangen GA, Ulsaker H, Manstad-H F, Di Giovanni P, Dahl SK, Langø T, Prot V. Prediction of guidewire-induced aortic deformations during EVAR: a finite element and in vitro study. Front Physiol 2023; 14:1098867. [PMID: 37492644 PMCID: PMC10365290 DOI: 10.3389/fphys.2023.1098867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Accepted: 06/20/2023] [Indexed: 07/27/2023] Open
Abstract
Introduction and aims: During an Endovascular Aneurysm Repair (EVAR) procedure a stiff guidewire is inserted from the iliac arteries. This induces significant deformations on the vasculature, thus, affecting the pre-operative planning, and the accuracy of image fusion. The aim of the present work is to predict the guidewire induced deformations using a finite element approach validated through experiments with patient-specific additive manufactured models. The numerical approach herein developed could improve the pre-operative planning and the intra-operative navigation. Material and methods: The physical models used for the experiments in the hybrid operating room, were manufactured from the segmentations of pre-operative Computed Tomography (CT) angiographies. The finite element analyses (FEA) were performed with LS-DYNA Explicit. The material properties used in finite element analyses were obtained by uniaxial tensile tests. The experimental deformed configurations of the aorta were compared to those obtained from FEA. Three models, obtained from Computed Tomography acquisitions, were investigated in the present work: A) without intraluminal thrombus (ILT), B) with ILT, C) with ILT and calcifications. Results and discussion: A good agreement was found between the experimental and the computational studies. The average error between the final in vitro vs. in silico aortic configurations, i.e., when the guidewire is fully inserted, are equal to 1.17, 1.22 and 1.40 mm, respectively, for Models A, B and C. The increasing trend in values of deformations from Model A to Model C was noticed both experimentally and numerically. The presented validated computational approach in combination with a tracking technology of the endovascular devices may be used to obtain the intra-operative configuration of the vessels and devices prior to the procedure, thus limiting the radiation exposure and the contrast agent dose.
Collapse
Affiliation(s)
- Monica Emendi
- Department of Industrial Engineering, University of Rome Tor Vergata, Rome, Italy
- Department of Health Research, SINTEF Digital, Trondheim, Norway
| | | | - Geir A. Tangen
- Department of Health Research, SINTEF Digital, Trondheim, Norway
| | - Håvard Ulsaker
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
| | - Frode Manstad-H
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
- Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim, Norway
| | | | - Sigrid K. Dahl
- Department of Health Research, SINTEF Digital, Trondheim, Norway
| | - Thomas Langø
- Department of Health Research, SINTEF Digital, Trondheim, Norway
| | - Victorien Prot
- Department of Structural Engineering, Norwegian University of Science and Technology, Trondheim, Norway
| |
Collapse
|
48
|
Xue A, Mao Z, Zhu X, Yang Q, Wang P, Mao Z, Du M, Ma X, Jiang D, Fan Y, Zhao F. Biomechanical effects of the medial meniscus horizontal tear and the resection strategy on the rabbit knee joint under resting state: finite element analysis. Front Bioeng Biotechnol 2023; 11:1164922. [PMID: 37425368 PMCID: PMC10324406 DOI: 10.3389/fbioe.2023.1164922] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 06/13/2023] [Indexed: 07/11/2023] Open
Abstract
The biomechanical changes following meniscal tears and surgery could lead to or accelerate the occurrence of osteoarthritis. The aim of this study was to investigate the biomechanical effects of horizontal meniscal tears and different resection strategies on a rabbit knee joint by finite element analysis and to provide reference for animal experiments and clinical research. Magnetic resonance images of a male rabbit knee joint were used to establish a finite element model with intact menisci under resting state. A medial meniscal horizontal tear was set involving 2/3 width of a meniscus. Seven models were finally established, including intact medial meniscus (IMM), horizontal tear of the medial meniscus (HTMM), superior leaf partial meniscectomy (SLPM), inferior leaf partial meniscectomy (ILPM), double-leaf partial meniscectomy (DLPM), subtotal meniscectomy (STM), and total meniscectomy (TTM). The axial load transmitted from femoral cartilage to menisci and tibial cartilage, the maximum von Mises stress and the maximum contact pressure on the menisci and cartilages, the contact area between cartilage to menisci and cartilage to cartilage, and absolute value of the meniscal displacement were analyzed and evaluated. The results showed that the HTMM had little effect on the medial tibial cartilage. After the HTMM, the axial load, maximum von Mises stress and maximum contact pressure on the medial tibial cartilage increased 1.6%, 1.2%, and 1.4%, compared with the IMM. Among different meniscectomy strategies, the axial load and the maximum von Mises stress on the medial menisci varied greatly. After the HTMM, SLPM, ILPM, DLPM, and STM, the axial load on medial menisci decreased 11.4%, 42.2%, 35.4% 48.7%, and 97.0%, respectively; the maximum von Mises stress on medial menisci increased 53.9%, 62.6%, 156.5%, and 65.5%, respectively, and the STM decreased 57.8%, compared to IMM. The radial displacement of the middle body of the medial meniscal was larger than any other part in all the models. The HTMM led to few biomechanical changes in the rabbit knee joint. The SLPM showed minimal effect on joint stress among all resection strategies. It is recommended to preserve the posterior root and the remaining peripheral edge of the meniscus during surgery for an HTMM.
Collapse
Affiliation(s)
- Anqi Xue
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
- Beijing Institute of Medical Device Testing, Beijing, China
| | - Zuming Mao
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xiaoyu Zhu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Qiang Yang
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Peichen Wang
- Beijing Institute of Medical Device Testing, Beijing, China
| | - Zimu Mao
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing Key Laboratory of Sports Injuries, Beijing, China
| | - Mingze Du
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing Key Laboratory of Sports Injuries, Beijing, China
| | - Xu Ma
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Dong Jiang
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing Key Laboratory of Sports Injuries, Beijing, China
| | - Yubo Fan
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Feng Zhao
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| |
Collapse
|
49
|
Sciberras T, Demicoli M, Grech I, Mallia B, Mollicone P, Sammut N. Thermo-Mechanical Fluid-Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications. Micromachines (Basel) 2023; 14:1264. [PMID: 37374848 DOI: 10.3390/mi14061264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 06/11/2023] [Accepted: 06/13/2023] [Indexed: 06/29/2023]
Abstract
Recent developments in MEMS technologies have made such devices attractive for use in applications that involve precision engineering and scalability. In the biomedical industry, MEMS devices have gained popularity in recent years for use as single-cell manipulation and characterisation tools. A niche application is the mechanical characterisation of single human red blood cells, which may exhibit certain pathological conditions that impart biomarkers of quantifiable magnitude that are potentially detectable via MEMS devices. Such applications come with stringent thermal and structural specifications wherein the potential device candidates must be able to function with no exceptions. This work presents a state-of-the-art numerical modelling methodology that is capable of accurately predicting MEMS device performance in various media, including aqueous ones. The method is strongly coupled in nature, whereby thermal as well as structural degrees of freedom are transferred to and from finite element and finite volume solvers at every iteration. This method therefore provides MEMS design engineers with a reliable tool that can be used in design and development stages and helps to avoid total reliability on experimental testing. The proposed numerical model is validated via a series of physical experiments. Four MEMS electrothermal actuators with cascaded V-shaped drivers are presented. With the use of the newly proposed numerical model as well as the experimental testing, the MEMS devices' suitability for biomedical applications is confirmed.
Collapse
Affiliation(s)
- Thomas Sciberras
- Department of Mechanical Engineering, Faculty of Engineering, University of Malta, MSD 2080 Msida, Malta
| | - Marija Demicoli
- Institute for Sustainable Energy, University of Malta, MXK 1531 Marsaxlokk, Malta
| | - Ivan Grech
- Department of Microelectronics and Nanoelectronics, Faculty of Information and Communications Technology, University of Malta, MSD 2080 Msida, Malta
| | - Bertram Mallia
- Department of Metallurgy and Materials Engineering, Faculty of Engineering, University of Malta, MSD 2080 Msida, Malta
| | - Pierluigi Mollicone
- Department of Mechanical Engineering, Faculty of Engineering, University of Malta, MSD 2080 Msida, Malta
| | - Nicholas Sammut
- Department of Microelectronics and Nanoelectronics, Faculty of Information and Communications Technology, University of Malta, MSD 2080 Msida, Malta
| |
Collapse
|
50
|
Amli SFM, Salleh MAAM, Aziz MSA, Yasuda H, Nogita K, Abdullah MMAB, Nemes O, Sandu AV, Vizureanu P. Effects of Multiple Reflow on the Formation of Primary Crystals in Sn-3.5Ag and Solder Joint Strength: Experimental and Finite Element Analysis. Materials (Basel) 2023; 16:4360. [PMID: 37374543 DOI: 10.3390/ma16124360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 06/03/2023] [Accepted: 06/07/2023] [Indexed: 06/29/2023]
Abstract
The growth and formation of primary intermetallics formed in Sn-3.5Ag soldered on copper organic solderability preservative (Cu-OSP) and electroless nickel immersion gold (ENIG) surface finish after multiple reflows were systematically investigated. Real-time synchrotron imaging was used to investigate the microstructure, focusing on the in situ growth behavior of primary intermetallics during the solid-liquid-solid interactions. The high-speed shear test was conducted to observe the correlation of microstructure formation to the solder joint strength. Subsequently, the experimental results were correlated with the numerical Finite Element (FE) modeling using ANSYS software to investigate the effects of primary intermetallics on the reliability of solder joints. In the Sn-3.5Ag/Cu-OSP solder joint, the well-known Cu6Sn5 interfacial intermetallic compounds (IMCs) layer was observed in each reflow, where the thickness of the IMC layer increases with an increasing number of reflows due to the Cu diffusion from the substrate. Meanwhile, for the Sn-3.5Ag/ENIG solder joints, the Ni3Sn4 interfacial IMC layer was formed first, followed by the (Cu, Ni)6Sn5 IMC layer, where the formation was detected after five cycles of reflow. The results obtained from real-time imaging prove that the Ni layer from the ENIG surface finish possessed an effective barrier to suppress and control the Cu dissolution from the substrates, as there is no sizeable primary phase observed up to four cycles of reflow. Thus, this resulted in a thinner IMC layer and smaller primary intermetallics, producing a stronger solder joint for Sn-3.5Ag/ENIG even after the repeated reflow process relative to the Sn-3.5Ag/Cu-OSP joints.
Collapse
Affiliation(s)
- Siti Farahnabilah Muhd Amli
- Center of Excellence Geopolymer & Green Technology (CeGeoGTech), University Malaysia Perlis (UniMAP), Taman Muhibbah, Kangar 02600, Malaysia
- Faculty of Chemical Engineering Technology, University Malaysia Perlis (UniMAP), Taman Muhibbah, Kangar 02600, Malaysia
| | - Mohd Arif Anuar Mohd Salleh
- Center of Excellence Geopolymer & Green Technology (CeGeoGTech), University Malaysia Perlis (UniMAP), Taman Muhibbah, Kangar 02600, Malaysia
- Faculty of Chemical Engineering Technology, University Malaysia Perlis (UniMAP), Taman Muhibbah, Kangar 02600, Malaysia
| | - Mohd Sharizal Abdul Aziz
- School of Mechanical Engineering, University Sains Malaysia, Nibong Tebal, Gelugor 14300, Malaysia
| | - Hideyuki Yasuda
- Department of Materials Science and Engineering, Kyoto University, Sakyo-ku, Kyoto 606-8501, Japan
| | - Kazuhiro Nogita
- Nihon Superior Centre for the Manufacture of Electronic Materials (NS CMEM), School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, QLD 4072, Australia
| | - Mohd Mustafa Al Bakri Abdullah
- Center of Excellence Geopolymer & Green Technology (CeGeoGTech), University Malaysia Perlis (UniMAP), Taman Muhibbah, Kangar 02600, Malaysia
| | - Ovidiu Nemes
- Department of Environmental Engineering and Sustainable Development Entrepreneurship, Faculty of Materials and Environmental Engineering, Technical University of Cluj-Napoca, B-dul Muncii 103-105, 400641 Cluj-Napoca, Romania
| | - Andrei Victor Sandu
- Faculty of Materials Science and Engineering, Gheorghe Asachi Technical University of Iasi, Blvd. D. Mangeron 71, 700050 Iasi, Romania
- Romanian Inventors Forum, Str. Sf. P. Movila 3, 700089 Iasi, Romania
| | - Petrica Vizureanu
- Faculty of Materials Science and Engineering, Gheorghe Asachi Technical University of Iasi, Blvd. D. Mangeron 71, 700050 Iasi, Romania
- Technical Sciences Academy of Romania, Dacia Blvd 26, 030167 Bucharest, Romania
| |
Collapse
|