1
|
Sadeqi S, Norte GE, Murray A, Erbulut DU, Goel VK. Effect of Whole Body Parameters on Knee Joint Biomechanics: Implications for ACL Injury Prevention During Single-Leg Landings. Am J Sports Med 2023; 51:2098-2109. [PMID: 37259968 DOI: 10.1177/03635465231174899] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
BACKGROUND Previous studies have examined the effect of whole body (WB) parameters on anterior cruciate ligament (ACL) strain and loads, as well as knee joint kinetics and kinematics. However, articular cartilage damage occurs in relation to ACL failure, and the effect of WB parameters on ACL strain and articular cartilage biomechanics during dynamic tasks is unclear. PURPOSES (1) To investigate the effect of WB parameters on ACL strain, as well as articular cartilage stress and contact force, during a single-leg cross drop (SLCD) and single-leg drop (SLD). (2) To identify WB parameters predictive of high ACL strain during these tasks. STUDY DESIGN Descriptive laboratory study. METHODS Three-dimensional motion analysis data from 14 physically active men and women were recorded during an SLCD and SLD. OpenSim was used to obtain their kinematics, kinetics, and muscle forces for the WB model. Using these data in kinetically driven finite element simulations of the knee joint produced outputs of ACL strains and articular cartilage stresses and contact forces. Spearman correlation coefficients were used to assess relationships between WB parameters and ACL strain and cartilage biomechanics. Moreover, receiver operating characteristic curve analyses and multivariate binary logistic regressions were used to find the WB parameters that could discriminate high from low ACL strain trials. RESULTS Correlations showed that more lumbar rotation away from the stance limb at peak ACL strain had the strongest overall association (ρ = 0.877) with peak ACL strain. Higher knee anterior shear force (ρ = 0.895) and lower gluteus maximus muscle force (ρ = 0.89) at peak ACL strain demonstrated the strongest associations with peak articular cartilage stress or contact force in ≥1 of the analyzed tasks. The regression model that used muscle forces to predict high ACL strain trials during the dominant limb SLD yielded the highest accuracy (93.5%), sensitivity (0.881), and specificity (0.952) among all regression models. CONCLUSION WB parameters that were most consistently associated with and predictive of high ACL strain and poor articular cartilage biomechanics during the SLCD and SLD tasks included greater knee abduction angle at initial contact and higher anterior shear force at peak ACL strain, as well as lower gracilis, gluteus maximus, and medial gastrocnemius muscle forces. CLINICAL RELEVANCE Knowledge of which landing postures create a high risk for ACL or cartilage injury may help reduce injuries in athletes by avoiding those postures and practicing the tasks with reduced high-risk motions, as well as by strengthening the muscles that protect the knee during single-leg landings.
Collapse
Affiliation(s)
- Sara Sadeqi
- Engineering Center for Orthopaedic Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedic Surgery, University of Toledo, Toledo, OH, USA
| | - Grant E Norte
- Motion Analysis and Integrative Neurophysiology Lab, Department of Exercise and Rehabilitation Sciences, College of Health and Human Services, University of Toledo, Toledo, Ohio, USA
| | - Amanda Murray
- Motion Analysis and Integrative Neurophysiology Lab, Department of Exercise and Rehabilitation Sciences, College of Health and Human Services, University of Toledo, Toledo, Ohio, USA
| | - Deniz U Erbulut
- Engineering Center for Orthopaedic Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedic Surgery, University of Toledo, Toledo, OH, USA
| | - Vijay K Goel
- Engineering Center for Orthopaedic Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedic Surgery, University of Toledo, Toledo, OH, USA
| |
Collapse
|
2
|
Daszkiewicz K, Łuczkiewicz P. Biomechanics of the medial meniscus in the osteoarthritic knee joint. PeerJ 2021; 9:e12509. [PMID: 34900428 PMCID: PMC8627128 DOI: 10.7717/peerj.12509] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Accepted: 10/27/2021] [Indexed: 11/20/2022] Open
Abstract
Background Increased mechanical loading and pathological response of joint tissue to the abnormal mechanical stress can cause degradation of cartilage characteristic of knee osteoarthritis (OA). Despite osteoarthritis is risk factor for the development of meniscal lesions the mechanism of degenerative meniscal lesions is still unclear. Therefore, the aim of the study is to investigate the influence of medial compartment knee OA on the stress state and deformation of the medial meniscus. Methods The finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. Degenerative changes in the medial knee OA model were simulated by nonuniform reduction in articular cartilage thickness in specific areas and by a decrease in the material parameters of cartilage and menisci. Two additional models were created to separately evaluate the effect of alterations in articular cartilage geometry and material parameters of the soft tissues on the results. A nonlinear dynamic analysis was performed for standardized knee loads applied to the tibia bone. Results The maximum von Mises stress of 26.8 MPa was observed in the posterior part of the medial meniscus body in the OA model. The maximal hoop stress for the first peak of total force was 83% greater in the posterior horn and only 11% greater in the anterior horn of the medial meniscus in the OA model than in the intact model. The reduction in cartilage thickness caused an increase of 57% in medial translation of the medial meniscus body. A decrease in the compressive modulus of menisci resulted in a 2.5-fold greater reduction in the meniscal body width compared to the intact model. Conclusions Higher hoop stress levels on the inner edge of the posterior part of the medial meniscus in the OA model than in the intact model are associated with a greater medial translation of the meniscus body and a greater reduction in its width. The considerable increase in hoop stresses shows that medial knee OA may contribute to the initiation of meniscal radial tears.
Collapse
Affiliation(s)
- Karol Daszkiewicz
- Department of Mechanics of Materials and Structures, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | - Piotr Łuczkiewicz
- II Department of Orthopaedics and Kinetic Organ Traumatology, Medical University of Gdańsk, Gdańsk, Poland
| |
Collapse
|
3
|
Donnelly CJ, Jackson C, Weir G, Alderson J, Robinson MA. Prescribing joint co-ordinates during model preparation in OpenSim improves lower limb unplanned sidestepping kinematics. J Sci Med Sport 2021; 24:159-163. [DOI: 10.1016/j.jsams.2020.07.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 05/22/2020] [Accepted: 07/19/2020] [Indexed: 10/23/2022]
|
4
|
Wang L, Wang CJ. Influence of tibial bearing curvatures of a customised total knee implant on squatting motion and loads. Comput Methods Biomech Biomed Engin 2020; 24:43-55. [PMID: 32840135 DOI: 10.1080/10255842.2020.1808970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
A range of preliminary designs of customised total knee implants (CTKIs) was created by resurfacing the distal femur and applying different tibial bearing surface curvatures. These were then compared with a scaled off-the-shelf symmetric total knee implant (STKI). To evaluate the biomechanical performance, a dynamic knee simulation model was created with patient-specific muscle and ankle joint loads calculated from an OpenSim musculoskeletal model. Simulation results showed the transverse curvatures of the tibial bearing surface influenced femoral mediolateral translation, while its longitudinal curvatures affected femoral adduction. Compared to the STKI, the CTKIs could restore patient knee function.
Collapse
Affiliation(s)
- Linjie Wang
- Department of Engineering and Design, University of Sussex, Falmer, Brighton, UK
| | - Chang Jiang Wang
- Department of Engineering and Design, University of Sussex, Falmer, Brighton, UK
| |
Collapse
|
5
|
Wang L, Wang CJ. Preliminary study of a customised total knee implant with musculoskeletal and dynamic squatting simulation. Proc Inst Mech Eng H 2019; 233:1010-1023. [DOI: 10.1177/0954411919865401] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Customised total knee replacement could be the future therapy for knee joint osteoarthritis. A preliminary design of a customised total knee implant based on knee anatomy was studied in this article. To evaluate its biomechanical performance, a dynamic finite element model based on the Oxford knee rig was created to simulate a squatting motion. Unlike previous research, this dynamic model was simulated with patient-specific muscle and joint loads that were calculated from an OpenSim musculoskeletal model. The dynamic response of the customised total knee implant was simulated under three cruciate ligament scenarios: both cruciate ligaments retained, only anterior cruciate ligament removed and both cruciate ligaments removed. In addition, an off-the-shelf symmetric total knee implant with retained cruciate ligaments was simulated for comparison analysis. The customised total knee implant with both cruciate ligaments retained showed larger ranges of femoral external rotation and posterior translation than the symmetric total knee implant. The motion of the customised total knee implant was also in good agreement with a healthy knee. There were no big differences in the tibiofemoral compressive forces in the customised total knee implant model under the three scenarios. These forces were generally consistent with other experimental and simulation results. However, the customised total knee implant design resulted in larger tibiofemoral compressive force than the symmetric total knee implant after 50° knee flexion, which was caused by the larger tibiofemoral relative motion.
Collapse
Affiliation(s)
- Linjie Wang
- Department of Engineering and Design, University of Sussex, Brighton, UK
| | - Chang Jiang Wang
- Department of Engineering and Design, University of Sussex, Brighton, UK
| |
Collapse
|
6
|
Luczkiewicz P, Daszkiewicz K, Witkowski W, Chróścielewski J, Ferenc T, Baczkowski B. The influence of a change in the meniscus cross-sectional shape on the medio-lateral translation of the knee joint and meniscal extrusion. PLoS One 2018; 13:e0193020. [PMID: 29447236 PMCID: PMC5814050 DOI: 10.1371/journal.pone.0193020] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Accepted: 02/02/2018] [Indexed: 01/09/2023] Open
Abstract
OBJECTIVE The purpose of this study was to evaluate the influence of a change in the meniscus cross sectional shape on its position and on the biomechanics of a knee joint. METHODS One main finite element model of a left knee joint was created on the basis of MRI images. The model consisted of bones, articular cartilages, menisci and ligaments. Eight variants of this model with an increased or decreased meniscus height were then prepared. Nonlinear static analyses with a fixed flexion/extension movement for a compressive load of 1000 N were performed. The additional analyses for those models with a constrained medio-lateral relative bone translation allowed for an evaluation of the influence of this translation on a meniscus external shift. RESULTS It was observed that a decrease in the meniscus height caused a decrease in the contact area, together with a decrease in the contact force between the flattened meniscus and the cartilage. For the models with an increased meniscus height, a maximal value of force acting on the meniscus in a medio-lateral direction was obtained. The results have shown that the meniscus external shift was approximately proportional to the meniscus slope angle, but that relationship was modified by a medio-lateral relative bone translation. It was found that the translation of the femur relative to the tibia may be dependent on the geometry of the menisci. CONCLUSIONS The results have suggested that a change in the meniscus geometry in the cross sectional plane can considerably affect not only the meniscal external shift, but also the medio-lateral translation of the knee joint as well as the congruency of the knee joint.
Collapse
MESH Headings
- Adult
- Biomechanical Phenomena
- Cartilage, Articular/anatomy & histology
- Cartilage, Articular/diagnostic imaging
- Cartilage, Articular/physiology
- Female
- Finite Element Analysis
- Humans
- Imaging, Three-Dimensional
- Knee Joint/anatomy & histology
- Knee Joint/diagnostic imaging
- Knee Joint/physiology
- Magnetic Resonance Imaging
- Menisci, Tibial/anatomy & histology
- Menisci, Tibial/diagnostic imaging
- Menisci, Tibial/physiology
- Models, Anatomic
- Models, Biological
- Stress, Mechanical
Collapse
Affiliation(s)
- Piotr Luczkiewicz
- II Clinic of Orthopaedics and Kinetic Organ Traumatology, Medical University of Gdansk, Gdansk, Poland
- * E-mail:
| | - Karol Daszkiewicz
- Department of Mechanics of Materials, Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Gdansk, Poland
| | - Wojciech Witkowski
- Department of Mechanics of Materials, Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Gdansk, Poland
| | - Jacek Chróścielewski
- Department of Mechanics of Materials, Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Gdansk, Poland
| | - Tomasz Ferenc
- Department of Mechanics of Materials, Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Gdansk, Poland
| | - Boguslaw Baczkowski
- II Clinic of Orthopaedics and Kinetic Organ Traumatology, Medical University of Gdansk, Gdansk, Poland
| |
Collapse
|
7
|
Tawy GF, Rowe P. Is the instrumented-pointer method of calibrating anatomical landmarks in 3D motion analysis reliable? J Biomech 2017; 53:205-209. [PMID: 28143654 DOI: 10.1016/j.jbiomech.2017.01.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Revised: 01/11/2017] [Accepted: 01/13/2017] [Indexed: 11/25/2022]
Abstract
Instrumented-pointers are often used to calibrate anatomical landmarks in biomechanical analyses. However, little is known about the effect of altering the orientation of the pointer during calibration on the co-ordinates recorded. Incorrect positioning of a landmark influences the axes created, and thus the kinematic data recorded. This study aimed to investigate the reliability of the pointer method for anatomical calibration. Two points were drawn onto a fixed box to resemble knee joint epicondyles, then a custom-made pointer was used to define the positions of these landmarks in three-dimensions. Twenty different pointer-orientations were chosen, and the position of the pointer in each of these orientations was recorded 8 times. Euclidean distances between single points were calculated for both landmarks and compared statistically (α = 0.05). Average Euclidean distances between all reconstructed points were 3.2±1.4mm (range: 0.3-7.1mm) for one landmark and 3.3±1.5mm (range: 0.3-7.9mm) for the other. The x- and y-co-ordinates recorded differed statistically when the pointer was moved about the X and Y axes (anterior/posterior and superior/inferior to landmark) (p < 0.05). No statistical differences were found between co-ordinates recorded when the pointer was moved around the Z axes (p > 0.05). ICC values for all co-ordinates were excellent, highlighting the reliability of the method (ICC > 0.90). These results support this method of anatomical calibration; however, we recommend that pointers be consistently held in a neutral oriented position (where the handle is not anterior, posterior, superior or inferior to the landmark) during calibration, to reduce the likelihood of calibration errors.
Collapse
Affiliation(s)
- Gwenllian Fflur Tawy
- The Department of Biomedical Engineering, University of Strathclyde, Wolfson Centre, 106 Rottenrow, Glasgow G4 0NW, United Kingdom.
| | - Philip Rowe
- The Department of Biomedical Engineering, University of Strathclyde, Wolfson Centre, 106 Rottenrow, Glasgow G4 0NW, United Kingdom.
| |
Collapse
|
8
|
Kia M, Schafer K, Lipman J, Cross M, Mayman D, Pearle A, Wickiewicz T, Imhauser C. A Multibody Knee Model Corroborates Subject-Specific Experimental Measurements of Low Ligament Forces and Kinematic Coupling During Passive Flexion. J Biomech Eng 2016; 138:051010. [PMID: 26926010 DOI: 10.1115/1.4032850] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2015] [Indexed: 11/08/2022]
Abstract
A multibody model of the knee was developed and the predicted ligament forces and kinematics during passive flexion corroborated subject-specific measurements obtained from a human cadaveric knee that was tested using a robotic manipulator. The model incorporated a novel strategy to estimate the slack length of ligament fibers based on experimentally measured ligament forces at full extension and included multifiber representations for the cruciates. The model captured experimentally measured ligament forces (≤ 5.7 N root mean square (RMS) difference), coupled internal rotation (≤ 1.6 deg RMS difference), and coupled anterior translation (≤ 0.4 mm RMS difference) through 130 deg of passive flexion. This integrated framework of model and experiment improves our understanding of how passive structures, such as ligaments and articular geometries, interact to generate knee kinematics and ligament forces.
Collapse
|
9
|
Gladnick BP, Boorman-Padgett J, Stone K, Kent RN, Cross MB, Mayman DJ, Pearle AD, Imhauser CW. Primary and coupled motions of the native knee in response to applied varus and valgus load. Knee 2016; 23:387-92. [PMID: 26875048 DOI: 10.1016/j.knee.2016.01.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2015] [Revised: 01/10/2016] [Accepted: 01/12/2016] [Indexed: 02/02/2023]
Abstract
BACKGROUND Knowledge of the complex kinematics of the native knee is a prerequisite for a successful reconstructive procedure. The aim of this study is to describe the primary and coupled motions of the native knee throughout the range of knee flexion, in response to applied varus and valgus loads. METHODS Twenty fresh-frozen cadaver knees were affixed to a six degree of freedom robotic arm with a universal force-moment sensor, and loaded with a 4Nm moment in varus and valgus at 0, 15, 30, 45, and 90° of knee flexion. The resulting tibiofemoral angulation, displacement, and rotation were recorded. RESULTS For each parameter investigated, the knee joint demonstrated more laxity at higher flexion angles. Varus angulation increased progressively from zero (2.0° varus) to 90 (5.2° varus) degrees of knee flexion (p<0.001). Valgus angulation also increased progressively, from zero (1.5° valgus) to 90 (3.9° valgus) degrees of knee flexion (p<0.001). At all flexion angles, the magnitude of tibiofemoral angle deviation was larger with varus than with valgus loading (p<0.05). CONCLUSIONS We conclude that the native knee exhibits small increases in coronal plane laxity as the flexion angle increases, and that the knee has generally more laxity under varus load than with valgus load throughout the Range of Motion (ROM). Larger differences in laxity of more than 2 to 3°, or peak laxity specifically during the range of mid-flexion, were not found in our cadaver model and are not likely to represent normal coronal plane kinematics. LEVEL OF EVIDENCE Level V, biomechanical cadaveric study.
Collapse
Affiliation(s)
- Brian P Gladnick
- Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, United States.
| | - James Boorman-Padgett
- Department of Biomechanics, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, United States
| | - Kyle Stone
- Department of Biomechanics, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, United States
| | - Robert N Kent
- Department of Biomechanics, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, United States
| | - Michael B Cross
- Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, United States
| | - David J Mayman
- Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, United States
| | - Andrew D Pearle
- Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, United States
| | - Carl W Imhauser
- Department of Biomechanics, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021, United States
| |
Collapse
|
10
|
Thouzé A, Monnet T, Bélaise C, Lacouture P, Begon M. A chain kinematic model to assess the movement of lower-limb including wobbling masses. Comput Methods Biomech Biomed Engin 2015. [DOI: 10.1080/10255842.2015.1053472] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
Robinson MA, Donnelly CJ, Tsao J, Vanrenterghem J. Impact of knee modeling approach on indicators and classification of anterior cruciate ligament injury risk. Med Sci Sports Exerc 2015; 46:1269-76. [PMID: 24300122 DOI: 10.1249/mss.0000000000000236] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
INTRODUCTION The aim of this study was to determine whether using a direct kinematic (DK) or inverse kinematic (IK) modeling approach could influence the estimation of knee joint kinematics, kinetics, and ACL injury risk classification during unanticipated side cutting. METHODS The three-dimensional motion and force data of 34 amateur Australian rules footballers conducting unanticipated side-cutting maneuvers were collected. The model used during the DK modeling approach was an eight-segment lower body model with the hip, knee, and ankle free to move in six degrees of freedom. During the IK modeling approach, the same eight-segment model was used; however, translational constraints were imposed on the hip, knee, and ankle joints. The similarity between kinematic and kinetic waveforms was evaluated using the root mean square difference (RMSD) and the one-dimensional statistical parametric mapping (SPM1D). The classification of an athlete's ACL injury risk was determined by correlating their peak knee moments with a predefined injury risk threshold. RESULTS The greatest RMSD occurred in the frontal plane joint angles (RMSD = 10.86°) and moments (RMSD = 0.67 ± 0.18 N·m·kg(-1)), which were also shown to be significantly different throughout the stance phase in the SPM1D analysis. Both DK and IK modeling approaches classified the same athletes as being at risk of ACL injury. CONCLUSIONS The choice of a DK or an IK modeling approach affected frontal plane estimates of knee joint angles and peak knee moments during the weight acceptance phase of unanticipated side cutting. However, both modeling approaches were similar in their classification of an athlete's ACL injury risk.
Collapse
Affiliation(s)
- Mark A Robinson
- 1School of Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, UNITED KINGDOM; and 2School of Sport Science, Exercise and Health, University of Western Australia, Perth, AUSTRALIA
| | | | | | | |
Collapse
|
12
|
Belvedere C, Ensini A, Leardini A, Dedda V, Feliciangeli A, Cenni F, Timoncini A, Barbadoro P, Giannini S. Tibio-femoral and patello-femoral joint kinematics during navigated total knee arthroplasty with patellar resurfacing. Knee Surg Sports Traumatol Arthrosc 2014; 22:1719-27. [PMID: 24408075 DOI: 10.1007/s00167-013-2825-0] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2013] [Accepted: 12/28/2013] [Indexed: 11/30/2022]
Abstract
PURPOSE In total knee arthroplasty, surgical navigation systems provide tibio-femoral joint (TFJ) tracking for relevant bone preparation, disregarding the patello-femoral joint (PFJ). Therefore, the important intra-operative assessment of the effect of component positioning, including the patella, on the kinematics of these two joints is not available. The objective of this study is to explore in vivo whether accurate tracking of the patella can result in a more physiological TFJ and PFJ kinematics during surgery. METHODS Ten patients underwent navigated knee replacement with patellar resurfacing. A secondary system was used to track patellar motion and PFJ kinematics using a special tracker. Patellar resection plane position and orientation were recorded using an instrumented probe. During all surgical steps, PFJ kinematics was measured in addition to TFJ kinematics. RESULTS Abnormal PFJ motion patterns were observed pre-operatively at the impaired knee. Patellar resection plane orientation on sagittal and transverse planes of 3.9° ± 9.0° and 0.4° ± 4.1° was found. A good restoration of both TFJ and PFJ kinematics was observed in all replaced knees after resurfacing, in particular the rotations in the three anatomical planes and medio-lateral patellar translation. CONCLUSIONS Patella tracking results in nearly physiological TFJ and PFJ kinematics in navigated knee arthroplasty with resurfacing. The intra-operative availability also of PFJ kinematics can support the positioning not only of the patellar component in case of resurfacing, but also of femoral and tibial components.
Collapse
Affiliation(s)
- C Belvedere
- Movement Analysis Laboratory and Functional - Clinical Evaluation of Prostheses, Centro di Ricerca Codivilla-Putti, Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy,
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Peeters K, Natsakis T, Burg J, Spaepen P, Jonkers I, Dereymaeker G, Vander Sloten J. An in vitro approach to the evaluation of foot-ankle kinematics: Performance evaluation of a custom-built gait simulator. Proc Inst Mech Eng H 2013; 227:955-67. [PMID: 23736995 DOI: 10.1177/0954411913490455] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Despite their well-known limitations, in vitro experiments have several benefits over in vivo techniques when exploring foot biomechanics under conditions characteristic of gait. In this study, we present a new setup for dynamic in vitro gait simulation that integrates a numerical model for generating the tibial kinematics control input, and we present an innovative methodology to measure full three-dimensional joint kinematics during gait simulations. The gait simulator applies forces to the tendons. Tibial kinematics in the sagittal plane is controlled using a numerical model that takes into account foot morphology. The methodology is validated by comparing joint rotations measured during gait simulation with those measured in vivo. In addition, reliability and accuracy of the control system as well as simulation input and output repeatability are quantified. The results reflect good control performance and repeatability of the control inputs, vertical ground reaction force, center of pressure displacement, and joint rotations and translations. In addition, there is a good correspondence to in vivo kinematics for most patterns of motion at the ankle, subtalar, and Chopart’s joints. Therefore, these results show the relevance and validity of including specimen-specific information for defining the control inputs.
Collapse
Affiliation(s)
- Koen Peeters
- Biomechanics Section, Mechanical Engineering Department, Faculty of Engineering KU Leuven, Belgium
| | - Tassos Natsakis
- Biomechanics Section, Mechanical Engineering Department, Faculty of Engineering KU Leuven, Belgium
| | - Josefien Burg
- Biomechanics Section, Mechanical Engineering Department, Faculty of Engineering KU Leuven, Belgium
| | | | - Ilse Jonkers
- Human Movement Biomechanics Section, Department of Kinesiology, KU Leuven, Belgium
| | - Greta Dereymaeker
- Biomechanics Section, Mechanical Engineering Department, Faculty of Engineering KU Leuven, Belgium
| | - Jos Vander Sloten
- Biomechanics Section, Mechanical Engineering Department, Faculty of Engineering KU Leuven, Belgium
| |
Collapse
|
14
|
Mononen ME, Jurvelin JS, Korhonen RK. Implementation of a gait cycle loading into healthy and meniscectomised knee joint models with fibril-reinforced articular cartilage. Comput Methods Biomech Biomed Engin 2013; 18:141-52. [PMID: 23570549 DOI: 10.1080/10255842.2013.783575] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Computational models can be used to evaluate the functional properties of knee joints and possible risk locations within joints. Current models with fibril-reinforced cartilage layers do not provide information about realistic human movement during walking. This study aimed to evaluate stresses and strains within a knee joint by implementing load data from a gait cycle in healthy and meniscectomised knee joint models with fibril-reinforced cartilages. A 3D finite element model of a knee joint with cartilages and menisci was created from magnetic resonance images. The gait cycle data from varying joint rotations, translations and axial forces were taken from experimental studies and implemented into the model. Cartilage layers were modelled as a fibril-reinforced poroviscoelastic material with the menisci considered as a transversely isotropic elastic material. In the normal knee joint model, relatively high maximum principal stresses were specifically predicted to occur in the medial condyle of the knee joint during the loading response. Bilateral meniscectomy increased stresses, strains and fluid pressures in cartilage on the lateral side, especially during the first 50% of the stance phase of the gait cycle. During the entire stance phase, the superficial collagen fibrils modulated stresses of cartilage, especially in the medial tibial cartilage. The present computational model with a gait cycle and fibril-reinforced biphasic cartilage revealed time- and location-dependent differences in stresses, strains and fluid pressures occurring in cartilage during walking. The lateral meniscus was observed to have a more significant role in distributing loads across the knee joint than the medial meniscus, suggesting that meniscectomy might initiate a post-traumatic process leading to osteoarthritis at the lateral compartment of the knee joint.
Collapse
Affiliation(s)
- Mika E Mononen
- a Department of Applied Physics , University of Eastern Finland , P.O. Box 1627, FI-70211 Kuopio , Finland
| | | | | |
Collapse
|