1
|
Wolny R, Wiczenbach T, Andrzejewska AJ, Spodnik JH. Mechanical response of human thoracic spine ligaments under quasi-static loading: An experimental study. J Mech Behav Biomed Mater 2024; 151:106404. [PMID: 38244422 DOI: 10.1016/j.jmbbm.2024.106404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 12/05/2023] [Accepted: 01/12/2024] [Indexed: 01/22/2024]
Abstract
PURPOSE This study aimed to investigate the geometrical and mechanical properties of human thoracic spine ligaments subjected to uniaxial quasi-static tensile test. METHODS Four human thoracic spines, obtained through a body donation program, were utilized for the study. The anterior longitudinal ligament (ALL), posterior longitudinal ligament (PLL), capsular ligament (CL), ligamenta flava (LF), and the interspinous ligament and supraspinous ligament complex (ISL + SSL), were investigated. The samples underwent specimen preparation, including dissection, cleaning, and reinforcement, before being immersed in epoxy resin. Uniaxial tensile tests were performed using a custom-designed mechanical testing machine equipped with an environmental chamber (T = 36.6 °C; humidity 95%). Then, the obtained tensile curves were averaged preserving the characteristic regions of typical ligaments response. RESULTS Geometrical and mechanical properties, such as initial length and width, failure load, and failure elongation, were measured. Analysis of variance (ANOVA) revealed significant differences among the ligaments for all investigated parameters. Pairwise comparisons using Tukey's post-hoc test indicated differences in initial length and width. ALL and PLL exhibited higher failure forces compared to CL and LF. ALL and ISL + SSL demonstrated biggest failure elongation. Comparisons with other studies showed variations in initial length, failure force, and failure elongation across different ligaments. The subsystem (Th1 - Th6 and Th7 - Th12) analysis revealed increases in initial length, width, failure force, and elongation for certain ligaments. CONCLUSIONS Variations of both the geometric and mechanical properties of the ligaments were noticed, highlighting their unique characteristics and response to tensile force. Presented results extend very limited experimental data base of thoracic spine ligaments existing in the literature. The obtained geometrical and mechanical properties can help in the development of more precise human body models (HBMs).
Collapse
Affiliation(s)
- R Wolny
- Department of Mechanics of Materials and Structures, Gdansk University of Technology, 80-233, Gdańsk, Poland
| | - T Wiczenbach
- Department of Mechanics of Materials and Structures, Gdansk University of Technology, 80-233, Gdańsk, Poland.
| | - A J Andrzejewska
- Department of Mechanics of Materials and Structures, Gdansk University of Technology, 80-233, Gdańsk, Poland
| | - J H Spodnik
- Department of Anatomy and Neurobiology, Medical University of Gdańsk, 80-210, Gdańsk, Poland
| |
Collapse
|
2
|
Bahrami S, Mirzadeh H, Solouk A, Duprez D. Bioinspired scaffolds based on aligned polyurethane nanofibers mimic tendon and ligament fascicles. Biotechnol J 2023; 18:e2300117. [PMID: 37440460 DOI: 10.1002/biot.202300117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Revised: 07/02/2023] [Accepted: 07/11/2023] [Indexed: 07/15/2023]
Abstract
Topographical factors of scaffolds play an important role in regulating cell functions. Although the effects of alignment topography and three-dimensional (3D) configuration of nanofibers as well as surface stiffness on cell behavior have been investigated, there are relatively few reports that attempt to understand the relationship between synergistic effects of these parameters and cell responses. Herein, the influence of biophysical and biomechanical cues of electrospun polyurethane (PU) scaffolds on mesenchymal stem cells (MSCs) activities was evaluated. To this aim, multiscale bundles were developed by rolling up the aligned electrospun mats mimicking the fascicles of tendons/ligaments and other similar tissues. Compared to mats, the 3D bundles not only maintained the desirable topographical features (i.e., fiber diameter, fiber orientation, and pore size), but also boosted tensile strength (∼40 MPa), tensile strain (∼260%), and surface stiffness (∼1.75 MPa). Alignment topography of nanofibers noticeably dictated cell elongation and a uniaxial orientation, resulting in tenogenic commitment of MSCs. MSCs seeded on the bundles expressed higher levels of tenogenic markers compared to mats. Moreover, the biomimetic bundle scaffolds improved synthesis of extracellular matrix components compared to mats. These results suggest that biophysical and biomechanical cues modulate cell-scaffold interactions, providing new insights into hierarchical scaffold design for further studies.
Collapse
Affiliation(s)
- Saeid Bahrami
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
- Institut Biologie Paris Seine-Laboratoire de Biologie du Développement, Centre National de la Recherche Scientifique (CNRS) UMR 7622, Institut National de la Santé Et de la Recherche Médicale (Inserm) U1156, Université Pierre et Marie Curie, Sorbonne Université, Paris, France
| | - Hamid Mirzadeh
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| | - Atefeh Solouk
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| | - Delphine Duprez
- Institut Biologie Paris Seine-Laboratoire de Biologie du Développement, Centre National de la Recherche Scientifique (CNRS) UMR 7622, Institut National de la Santé Et de la Recherche Médicale (Inserm) U1156, Université Pierre et Marie Curie, Sorbonne Université, Paris, France
| |
Collapse
|
3
|
Sabik A, Witkowski W. On implementation of fibrous connective tissues' damage in Abaqus software. J Biomech 2023; 157:111736. [PMID: 37517283 DOI: 10.1016/j.jbiomech.2023.111736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Revised: 06/26/2023] [Accepted: 07/19/2023] [Indexed: 08/01/2023]
Abstract
Connective fibrous tissues, such as tendons and ligaments, in humans and animals exhibit hyperelastic behaviour. The constitution of the material of these tissues is anisotropic due to the presence of the collagen fibres, where one family of fibres is the typical case. Traumatic events and/or aging may sometimes lead to the damage of the tissue. The study of motion of affected joints or limbs is usually not permitted in vivo. This is where finite element method (FEM) becomes useful as a premise for general analysis, surgical planning or designing of implants and medical treatment. One of the most often used FEM commercial programs is the field of the biomechanics is Abaqus. The present study discusses the potential of user subroutine UANISOHYPER_INV in this code to analyse response of transversely isotropic tissue with damage in quasi-static range. This subroutine requires providing the material energy function and its derivatives only. The stress tensor and constitutive matrix are computed by the software automatically. To the best of the Authors' knowledge this procedure provides the easiest way to simulate the anisotropic hyperelastic material behaviour in Abaqus. In this study its usage is extended onto the damage response simulation. The verification of the approach and its validation against experimental data indicates its efficiency.
Collapse
Affiliation(s)
- Agnieszka Sabik
- Department of Mechanics of Materials and Structures, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland.
| | - Wojciech Witkowski
- Department of Mechanics of Materials and Structures, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland
| |
Collapse
|
4
|
Minster PH, Lafon Y, Beillas P. Implications of range of motion requirements for the laxity of ligaments in a lumbar finite element model. J Biomech 2023; 148:111460. [PMID: 36773483 DOI: 10.1016/j.jbiomech.2023.111460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 12/20/2022] [Accepted: 01/18/2023] [Indexed: 01/22/2023]
Abstract
Finite element models of the lumbar spine often adopt ligament properties from tensile tests without accounting for possible differences between testing and in situ initial ligament length. Such differences could result in laxities or preloads at the beginning of a simulation that would affect the ligament forces, tangent stiffness, and the posture at which they fail. In vivo and in vitro human experimental data reported laxities or preloads. However, laxities or preloads, which could also result from postural differences, are often neglected in simulation studies. This study proposes a numerical methodology to identify ranges of ligament laxities or preloads compatible with the selected tensile ligament properties, the model, and the range of motion (RoM) the model aims to simulate. The approach assumes that ligaments should remain in a safe elongation range for the complete RoM, and that each ligament should play a significant mechanical role in at least one load case. The methodology was applied to the functional spinal unit (FSU) models using the RoM from healthy subjects and ligament properties from the literature. Without laxity, some ligaments reached their elongation at failure within the RoM. Laxity ranges varied considerably (from -9.2 mm preload to 10.7 mm laxity) and flexion was the most critical load case to determine them. Their effect on the mobility response was also assessed. The effect on the mobility of a FSU was also assessed. While the proposed method cannot determine an exact laxity value, it is simple and it can be applied to any model to identify a plausible range of ligament initial length.
Collapse
Affiliation(s)
- Pierre-Hugo Minster
- Université de Lyon, Université Claude Bernard Lyon 1, Université Gustave Eiffel, LBMC UMR_T 9406, F-69622 Lyon, France
| | - Yoann Lafon
- Université de Lyon, Université Claude Bernard Lyon 1, Université Gustave Eiffel, LBMC UMR_T 9406, F-69622 Lyon, France
| | - Philippe Beillas
- Université de Lyon, Université Claude Bernard Lyon 1, Université Gustave Eiffel, LBMC UMR_T 9406, F-69622 Lyon, France.
| |
Collapse
|
5
|
Luo J, Swenson CW, Betschart C, Feng F, Wang H, Ashton-Miller JA, DeLancey JOL. Comparison of in vivo visco-hyperelastic properties of uterine suspensory tissue in women with and without pelvic organ prolapse. J Mech Behav Biomed Mater 2023; 137:105544. [PMID: 36332398 DOI: 10.1016/j.jmbbm.2022.105544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Revised: 10/15/2022] [Accepted: 10/24/2022] [Indexed: 11/05/2022]
Abstract
The uterine suspensory tissue (UST) complex includes the cardinal (CL) and uterosacral "ligaments" (USL), which are mesentery-like structures that play a role in resisting pelvic organ prolapse (POP). Since there is no information on the time-dependent material properties of the whole structure in situ and in vivo, we developed and tested an intraoperative technique to quantify in vivo whether there is a significant difference in visco-hyperelastic behavior of the CL and USL between women with and without POP. Thirteen women with POP (cases) and four controls scheduled for surgery were selected from an ongoing POP study. Immediately prior to surgery, a computer-controlled linear servo-actuator with a series force transducer applied a continuous, caudally directed traction force while simultaneously recording the resulting cervical displacement in the same direction. After applying an initial 1.1 N preload, a ramp rate of 4 mm/s was used to apply a maximum force of 17.8 N in three "ramp-and-hold" test trials. A simplified bilateral four-cable biomechanical model was used to identify the material behavior of each ligament. For this, the initial cross-section areas of the CL and USL were measured on 3-T magnetic resonance image-based 3D models from each subject. The time-dependent strain energy function of CL/USL was defined with a three-parameter hyperelastic Mooney-Rivlin material model and a two-term Prony series in relaxation form. When cases were compared with controls, the estimated time-dependent material constants of CL and USL did not differ significantly. These are the first measurements that compare the in vivo and in situ visco-hyperelastic response of the tissues comprising the CL and USL to loading in women with and without prolapse. Larger sample sizes would help improve the precision of intergroup differences.
Collapse
Affiliation(s)
- Jiajia Luo
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA; Biomedical Engineering Department, Peking University, Beijing, China.
| | - Carolyn W Swenson
- Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, Michigan, USA
| | - Cornelia Betschart
- Department of Gynecology, University Hospital of Zurich, Zurich, Switzerland
| | - Fei Feng
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University, Shanghai, China
| | - Hui Wang
- Biomedical Engineering Department, Peking University, Beijing, China
| | - James A Ashton-Miller
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - John O L DeLancey
- Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|
6
|
Donaldson K, Thomas J, Zhu Y, Clark-Deener S, Alperin M, De Vita R. In-plane and out-of-plane deformations of gilt utero-sacral ligaments. J Mech Behav Biomed Mater 2022; 131:105249. [PMID: 35526346 DOI: 10.1016/j.jmbbm.2022.105249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 04/07/2022] [Accepted: 04/17/2022] [Indexed: 11/27/2022]
Abstract
The uterosacral ligaments (USLs) are supportive structures of the uterus and apical vagina. The mechanical function of these ligaments within the pelvic floor is crucial not only in normal physiological conditions but also in reconstructive surgeries for pelvic organ prolapse. Discrepancies in their anatomical and histological description exist in the literature, but such discrepancies are likely due to large variations of these structures. This makes mechanical testing very challenging, requiring the development of advanced methods for characterizing their mechanical properties. This study proposes the use of planar biaxial testing, digital image correlation (DIC), and optical coherence tomography (OCT) to quantify the deformations of the USLs, both in-plane and out-of-plane. Using the gilts as an animal model, the USLs were found to deform significantly less in their main direction (MD) of in vivo loading than in the direction perpendicular to it (PD) at increasing equibiaxial stresses. Under constant equibiaxial loading, the USLs deform over time equally, at comparable rates in both the MD and PD. The thickness of the USLs decreases as the equibiaxial loading increases but, under constant equibiaxial loading, the thickness increases in some specimens and decreases in others. These findings could contribute to the design of new mesh materials that augment the support function of USLs as well as noninvasive diagnostic tools for evaluating the integrity of the USLs.
Collapse
Affiliation(s)
- Kandace Donaldson
- Department of Biomedical Engineering and Mechanics, Virginia Tech, 330A Kelly Hall, 325 Stanger Street, Blacksburg, VA, 24061, USA
| | - Joseph Thomas
- Department of Electrical and Computer Engineering, Virginia Tech, 460 Turner Street, Suite 303, Blacksburg, VA, 24061, USA
| | - Yizheng Zhu
- Department of Electrical and Computer Engineering, Virginia Tech, 460 Turner Street, Suite 303, Blacksburg, VA, 24061, USA
| | - Sherrie Clark-Deener
- Department of Large Animal Clinical Sciences, Virginia Tech, 215 Duckpond Drive, Blacksburg, VA, 24061, USA
| | - Marianna Alperin
- Department of Obstetrics, Gynecology & Reproductive Sciences, Division of Female Medicine and Reconstructive Surgery, University of California San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA
| | - Raffaella De Vita
- Department of Biomedical Engineering and Mechanics, Virginia Tech, 330A Kelly Hall, 325 Stanger Street, Blacksburg, VA, 24061, USA.
| |
Collapse
|
7
|
Abstract
As the resolution of 3D printing techniques improves, the possibility of individualized, 3-ossicle constructions adds a new dimension to middle ear prostheses. In order to optimize these designs, it is essential to understand how the ossicles and ligaments work together to transmit sound, and thus how ligaments should be replicated in a middle ear reconstruction. The middle ear ligaments are thought to play a significant role in maintaining the position of the ossicles and constraining axis of rotation. Paradoxically, investigations of the role of ligaments to date have shown very little impact on middle ear sound transmission. We explored the role of the two attachments in the gerbil middle ear analogous to human ligaments, the posterior incudal ligament and the anterior mallear process, severing both attachments and measuring change in hearing sensitivity. The impact of severing the attachments on the position of the ossicular chain was visualized using synchrotron microtomography imaging of the middle ear. In contrast to previous studies, a threshold change on the order of 20 dB across a wide range of frequencies was found when both ligaments were severed. Concomitantly, a shift in position of the ossicles was observed from the x-ray imaging and 3D renderings of the ossicular chain. These findings contrast with previous studies, demonstrating that these ligaments play a significant role in the transmission of sound through the middle ear. It appears that both mallear and incudal ligaments must be severed in order to impair sound transmission. The results of this study have significance for middle ear reconstructive surgery and the design of 3D-printed three-ossicle biocompatible prostheses.
Collapse
Affiliation(s)
- Eileen Y. Brister
- Department of Otolaryngology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, United States of America
- Department of Speech, Language, and Hearing Sciences, Indiana University, Bloomington, Indiana, United States of America
| | - Robert H. Withnell
- Department of Speech, Language, and Hearing Sciences, Indiana University, Bloomington, Indiana, United States of America
| | - Pavel Shevchenko
- Advanced Photon Source, Argonne National Lab, Lemont, Illinois, United States of America
| | - Claus-Peter Richter
- Department of Otolaryngology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, United States of America
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, United States of America
- Department of Communication Sciences and Disorders, Northwestern University, Evanston, Illinois, United States of America
- The Hugh Knowles Center, Northwestern University, Evanston, Illinois, United States of America
- * E-mail:
| |
Collapse
|
8
|
Lutz PM, Feucht MJ, Wechselberger J, Rasper M, Petersen W, Wörtler K, Imhoff AB, Achtnich A. Ultrasound-based examination of the medial ligament complex shows gender- and age-related differences in laxity. Knee Surg Sports Traumatol Arthrosc 2021; 29:1960-1967. [PMID: 32965547 PMCID: PMC8126541 DOI: 10.1007/s00167-020-06293-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Accepted: 09/14/2020] [Indexed: 11/26/2022]
Abstract
PURPOSE Ultrasound (US) examination of the medial joint space of the knee has played a subordinate diagnostic role up till now. The purpose of the present study was to describe mean values of medial joint width and to investigate the impact of gender, age, and body mass index (BMI) on medial joint laxity in healthy knees using modern, dynamic US in a standardized fashion in unloaded and standardized loaded conditions. METHODS A total of 65 subjects with 79 healthy knees were enrolled in this study. All volunteers underwent clinical examination of the knee. The medial knee joint width was determined using US in a supine position at 0° and 30° of knee flexion in unloaded and standardized loaded (= 15 Dekanewton, daN) conditions using a specific device. Mean values were described and correlations between medial knee joint width and gender, age, and BMI were assessed. RESULTS Thirty-two females and 33 males were enrolled in this study. The mean medial joint width in 0° unloaded was 5.7 ± 1.2 mm and 7.4 ± 1.4 mm loaded. In 30° of knee flexion, the mean medial joint width was 6.1 ± 1.1 mm unloaded and 7.8 ± 1.2 mm loaded. The average change between unloaded and loaded conditions in 0° was 1.7 ± 1.0 mm and in 30° 1.7 ± 0.9 mm. A significant difference between genders was evident for medial joint width in 0° and 30° of flexion in unloaded and loaded conditions (p < 0.05). With rising age, a significant increased change of medial joint space width between unloaded and loaded conditions could be demonstrated in 0° (p = 0.032). No significant correlation between BMI and medial joint width in US could be found. CONCLUSION Mean values of medial joint width in unloaded and standardized loaded conditions using a fixation device could be demonstrated. Based on the results of this study, medial knee joint width in US is gender- and age-related in healthy knees. These present data may be useful for evaluating patients with acute or chronic pathologies to the medial side of the knee. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Patricia M Lutz
- Department for Orthopedic Sports Medicine, Technical University Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Matthias J Feucht
- Department for Orthopedic Sports Medicine, Technical University Munich, Ismaninger Str. 22, 81675, Munich, Germany
- Department of Orthopedics and Trauma Surgery, Medical Center, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany
| | - Judith Wechselberger
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munich, Germany
| | - Michael Rasper
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munich, Germany
| | | | - Klaus Wörtler
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munich, Germany
| | - Andreas B Imhoff
- Department for Orthopedic Sports Medicine, Technical University Munich, Ismaninger Str. 22, 81675, Munich, Germany.
| | - Andrea Achtnich
- Department for Orthopedic Sports Medicine, Technical University Munich, Ismaninger Str. 22, 81675, Munich, Germany
| |
Collapse
|
9
|
Vita G, Zanata AM, Datovo A. Anatomy and ontogenetic changes of the facial and gular musculature of the tetra Astyanax brucutu: A remarkable case of adaptation to durophagy. J Anat 2020; 237:1136-1150. [PMID: 32735750 PMCID: PMC7704242 DOI: 10.1111/joa.13280] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 06/10/2020] [Accepted: 06/23/2020] [Indexed: 11/29/2022] Open
Abstract
Astyanax brucutu is a peculiar species of Neotropical tetra endemic from the Chapada Diamantina, a large plateau in northeastern Brazil. Individuals of this species undergo a dramatic ontogenetic shift in their diet that is accompanied by equally remarkable changes in their feeding apparatus. Whereas juveniles of A. brucutu feed mostly on algae, adults feed almost exclusively on an endemic species of hydrobiid snail and other associated living organisms that inhabit their dead shells (including infaunal invertebrates and algae). Skeletal adaptations associated with this change in diet were previously reported, but until now, the changes in the musculature remained mostly unknown. The present paper describes the facial and gular muscles, as well as the buccal ligaments of A. brucutu in different life stages, and identifies the major ontogenetic changes in these systems associated with the diet shift in the species. Such changes primarily involve expansions of specific portions of the adductor mandibulae and associated tendons and ligaments that likely represent adaptations to increase the biting power necessary to crush copious amounts of shells ingested by larger individuals of A. brucutu. Those adaptations are absent in specimens of any size of Astyanax cf. fasciatus, a sympatric congener lacking durophagous feeding habits. Anatomical comparisons and landmark-based principal components analysis (PCA) suggest that most specializations to durophagy in A. brucutu arose by peramorphosis. We also found that several of the muscular specializations of adults of A. brucutu are paralleled in species of Creagrutus and Piabina, two other characid genera distantly related to Astyanax, but that also feed on hard food items.
Collapse
Affiliation(s)
- George Vita
- Instituto de BiologiaUniversidade Federal da BahiaSalvadorBABrazil
- Laboratório de IctiologiaMuseu de Zoologia da Universidade de São PauloSão PauloSPBrazil
| | | | - Aléssio Datovo
- Laboratório de IctiologiaMuseu de Zoologia da Universidade de São PauloSão PauloSPBrazil
| |
Collapse
|
10
|
Dyment NA, Barrett JG, Awad H, Bautista CA, Banes A, Butler DL. A brief history of tendon and ligament bioreactors: Impact and future prospects. J Orthop Res 2020; 38:2318-2330. [PMID: 32579266 PMCID: PMC7722018 DOI: 10.1002/jor.24784] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Revised: 05/28/2020] [Accepted: 06/12/2020] [Indexed: 02/04/2023]
Abstract
Bioreactors are powerful tools with the potential to model tissue development and disease in vitro. For nearly four decades, bioreactors have been used to create tendon and ligament tissue-engineered constructs in order to define basic mechanisms of cell function, extracellular matrix deposition, tissue organization, injury, and tissue remodeling. This review provides a historical perspective of tendon and ligament bioreactors and their contributions to this advancing field. First, we demonstrate the need for bioreactors to improve understanding of tendon and ligament function and dysfunction. Next, we detail the history and evolution of bioreactor development and design from simple stretching of explants to fabrication and stimulation of two- and three-dimensional constructs. Then, we demonstrate how research using tendon and ligament bioreactors has led to pivotal basic science and tissue-engineering discoveries. Finally, we provide guidance for new basic, applied, and clinical research utilizing these valuable systems, recognizing that fundamental knowledge of cell-cell and cell-matrix interactions combined with appropriate mechanical and chemical stimulation of constructs could ultimately lead to functional tendon and ligament repairs in the coming decades.
Collapse
Affiliation(s)
- Nathaniel A. Dyment
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA
| | - Jennifer G. Barrett
- Department of Large Animal Clinical Sciences, Marion duPont Scott Equine Medical Center, Virginia Tech, Leesburg, VA
| | - Hani Awad
- Department of Biomedical Engineering, The Center for Musculoskeletal Research, University of Rochester, Rochester, NY 14627
| | | | - Albert Banes
- Flexcell International Corp., 2730 Tucker St., Suite 200, Burlington, 27215, NC
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC
| | - David L. Butler
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, 45221
| |
Collapse
|
11
|
Rhatomy S, Prasetyo TE, Setyawan R, Soekarno NR, Romaniyanto FNU, Sedjati AP, Sumarwoto T, Utomo DN, Suroto H, Mahyudin F, Prakoeswa CRS. Prospect of stem cells conditioned medium (secretome) in ligament and tendon healing: A systematic review. Stem Cells Transl Med 2020; 9:895-902. [PMID: 32304180 PMCID: PMC7381802 DOI: 10.1002/sctm.19-0388] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Revised: 03/05/2020] [Accepted: 03/22/2020] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Tendon or ligament tears can decrease patients' quality of life. Many therapeutic interventions are available to treat such injuries. Mesenchymal stem cells (MSCs) have been shown to be effective in treating tendon or ligament tears; however, the use of stem cell-conditioned medium (CM) requires further investigation. This review focused on the use of stem cell CM as treatment for tendon or ligament tears. METHODS A systematic literature search was performed on PubMed (MEDLINE), OVID, EMBASE, the Cochrane Library, Scopus, Web of Science, and Science Direct with the terms conditioned media or conditioned medium or secretome or microvesicle or extracellular vesicle or exosome, and tendon or ligament as the search keywords. A total of 852 articles were reviewed. Five articles were identified as relevant for this systematic review. RESULTS Meta-analysis could not be performed because of the high heterogeneity of the reviewed studies; however, the results of this study support a positive effect of conditioned media in tendon and ligament treatment. CONCLUSION This review provides evidence of improvement in the tendon and ligament healing process with stem cell CM therapy in preclinical studies.
Collapse
Affiliation(s)
- Sholahuddin Rhatomy
- Department of Orthopaedics and TraumatologyDr. Soeradji Tirtonegoro General HospitalKlatenIndonesia
- Faculty of Medicine, Public Health, and NursingUniversitas Gadjah MadaYogyakartaIndonesia
| | - Thomas Edison Prasetyo
- Soeradji Tirtonegoro Sport Center and Research UnitDr. Soeradji Tirtonegoro General HospitalKlatenIndonesia
| | - Riky Setyawan
- Soeradji Tirtonegoro Sport Center and Research UnitDr. Soeradji Tirtonegoro General HospitalKlatenIndonesia
| | | | - FNU Romaniyanto
- Department of Orthopaedics and TraumatologySurakartaIndonesia
- Faculty of MedicineUniversitas Sebelas MaretSurakartaIndonesia
| | - Andi Priyo Sedjati
- Department of Orthopaedics and TraumatologySurakartaIndonesia
- Faculty of MedicineUniversitas Sebelas MaretSurakartaIndonesia
| | - Tito Sumarwoto
- Department of Orthopaedics and TraumatologySurakartaIndonesia
- Faculty of MedicineUniversitas Sebelas MaretSurakartaIndonesia
| | - Dwikora Novembri Utomo
- Department of Orthopaedics and TraumatologyDr. Soetomo General HospitalSurabayaIndonesia
- Faculty of MedicineUniversitas AirlanggaSurabayaIndonesia
| | - Heri Suroto
- Department of Orthopaedics and TraumatologyDr. Soetomo General HospitalSurabayaIndonesia
- Faculty of MedicineUniversitas AirlanggaSurabayaIndonesia
| | - Ferdiansyah Mahyudin
- Department of Orthopaedics and TraumatologyDr. Soetomo General HospitalSurabayaIndonesia
- Faculty of MedicineUniversitas AirlanggaSurabayaIndonesia
| | - Cita Rosita Sigit Prakoeswa
- Faculty of MedicineUniversitas AirlanggaSurabayaIndonesia
- Department of Dermatology and VenereologyDr. Soetomo General HospitalSurabayaIndonesia
| |
Collapse
|
12
|
No YJ, Castilho M, Ramaswamy Y, Zreiqat H. Role of Biomaterials and Controlled Architecture on Tendon/Ligament Repair and Regeneration. Adv Mater 2020; 32:e1904511. [PMID: 31814177 DOI: 10.1002/adma.201904511] [Citation(s) in RCA: 66] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2019] [Revised: 11/10/2019] [Indexed: 06/10/2023]
Abstract
Engineering synthetic scaffolds to repair and regenerate ruptured native tendon and ligament (T/L) tissues is a significant engineering challenge due to the need to satisfy both the unique biological and biomechanical properties of these tissues. Long-term clinical outcomes of synthetic scaffolds relying solely on high uniaxial tensile strength are poor with high rates of implant rupture and synovitis. Ideal biomaterials for T/L repair and regeneration need to possess the appropriate biological and biomechanical properties necessary for the successful repair and regeneration of ruptured tendon and ligament tissues.
Collapse
Affiliation(s)
- Young Jung No
- Biomaterials and Tissue Engineering Research Unit, School of Biomedical Engineering, University of Sydney, Sydney, NSW, 2006, Australia
- Australian Research Council Training Centre for Innovative BioEngineering, Sydney, NSW, 2006, Australia
| | - Miguel Castilho
- Department of Orthopedics, University Medical Center Utrecht, Utrecht University, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
- Department of Biomedical Engineering, Eindhoven University of Technology, 5600 MB, Eindhoven, The Netherlands
| | - Yogambha Ramaswamy
- Biomaterials and Tissue Engineering Research Unit, School of Biomedical Engineering, University of Sydney, Sydney, NSW, 2006, Australia
- Australian Research Council Training Centre for Innovative BioEngineering, Sydney, NSW, 2006, Australia
| | - Hala Zreiqat
- Biomaterials and Tissue Engineering Research Unit, School of Biomedical Engineering, University of Sydney, Sydney, NSW, 2006, Australia
- Australian Research Council Training Centre for Innovative BioEngineering, Sydney, NSW, 2006, Australia
- Radcliffe Institute for Advanced Study, Harvard University, Cambridge, MA, 02138, USA
| |
Collapse
|
13
|
Leong NL, Kator JL, Clemens TL, James A, Enamoto-Iwamoto M, Jiang J. Tendon and Ligament Healing and Current Approaches to Tendon and Ligament Regeneration. J Orthop Res 2020; 38:7-12. [PMID: 31529731 PMCID: PMC7307866 DOI: 10.1002/jor.24475] [Citation(s) in RCA: 79] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Accepted: 09/10/2019] [Indexed: 02/04/2023]
Abstract
Ligament and tendon injuries are common problems in orthopedics. There is a need for treatments that can expedite nonoperative healing or improve the efficacy of surgical repair or reconstruction of ligaments and tendons. Successful biologically-based attempts at repair and reconstruction would require a thorough understanding of normal tendon and ligament healing. The inflammatory, proliferative, and remodeling phases, and the cells involved in tendon and ligament healing will be reviewed. Then, current research efforts focusing on biologically-based treatments of ligament and tendon injuries will be summarized, with a focus on stem cells endogenous to tendons and ligaments. Statement of clinical significance: This paper details mechanisms of ligament and tendon healing, as well as attempts to apply stem cells to ligament and tendon healing. Understanding of these topics could lead to more efficacious therapies to treat ligament and tendon injuries. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:7-12, 2020.
Collapse
Affiliation(s)
- Natalie L Leong
- Department of Orthopaedic Surgery, University of Maryland, 10 N. Greene St., Baltimore, Maryland, 21201
- Department of Surgery, Baltimore VA Medical Center, Baltimore, Maryland
| | - Jamie L Kator
- Department of Orthopaedic Surgery, University of Maryland, 10 N. Greene St., Baltimore, Maryland, 21201
| | - Thomas L Clemens
- Department of Orthopaedic Surgery, University of Maryland, 10 N. Greene St., Baltimore, Maryland, 21201
- Department of Orthopaedic Surgery, Johns Hopkins University, Baltimore, Maryland
| | - Aaron James
- Department of Pathology, Johns Hopkins University, Baltimore, Maryland
| | - Motomi Enamoto-Iwamoto
- Department of Orthopaedic Surgery, University of Maryland, 10 N. Greene St., Baltimore, Maryland, 21201
| | - Jie Jiang
- Department of Orthopaedic Surgery, University of Maryland, 10 N. Greene St., Baltimore, Maryland, 21201
| |
Collapse
|
14
|
Suzuki M, Kubota K, Nishimura R, Negishi L, Komatsu K, Kagi H, Rehav K, Cohen S, Weiner S. A unique methionine-rich protein-aragonite crystal complex: Structure and mechanical functions of the Pinctada fucata bivalve hinge ligament. Acta Biomater 2019; 100:1-9. [PMID: 31604125 DOI: 10.1016/j.actbio.2019.10.008] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Revised: 10/01/2019] [Accepted: 10/01/2019] [Indexed: 11/28/2022]
Abstract
The bivalve hinge ligament holds the two shells together. The ligament functions as a spring to open the shells after they were closed by the adductor muscle. The ligament is a mineralized tissue that bears no resemblance to any other known tissue. About half the ligament is composed of a protein-rich matrix, and half of long and extremely thin segmented aragonite crystals. Here we study the hinge ligament of the pearl oyster Pinctada fucata. FIB SEM shows that the 3D organization is remarkably ordered. The full sequence of the major protein component contains a continuous segment of 30 repeats of MMMLPD. There is no known homologous protein. Knockdown of this protein prevents crystal formation, demonstrating that the integrity of the matrix is necessary for crystals to form. X-ray diffraction shows that the aragonite crystals are more aligned in the compressed ligament, indicating that the crystals may be actively contributing to the elastic properties. The fusion interphase that joins the ligament to the shell nacre is composed of a prismatic mineralized tissue with a thin organic-rich layer at its center. Nanoindentation of the dry interphase shows that the elastic modulus of the nacre adjacent to the interphase gradually decreases until it approximates that of the interphase. The interphase modulus slightly increases until it matches the ligament. All these observations demonstrate that the ligament shell complex is a remarkable biological tissue that has evolved unique properties that enable bivalves to open their shell effectively innumerable times during the lifetime of the animal. STATEMENT OF SIGNIFICANCE: The hinge ligament shell complex is a unique functioning structural tissue whose elastic properties enable the shell to open without expending energy. Methionine-rich proteins are not known elsewhere raising fundamental questions about secondary and tertiary structures contributing to its elastic properties. The segmented and extremely thin aragonite crystals embedded in this matrix may also have unexpected elastic materials properties as they flex during compression. The structure of the interphase comprises a fascinating biological joint that connects two very different materials. The interphase materials, including the nacre, are graded with respect to elastic modulus so as to approximately match the connecting components. The interphase incorporates a thin organic rich layer that presumably functions as a gasket. This study raises many fundamental questions relevant to the diverse fields of protein chemistry, biomineralization and biological materials.
Collapse
Affiliation(s)
- Michio Suzuki
- Department of Applied Biological Chemistry, Graduate School of Agricultural and Life Sciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo-ku, Tokyo 113-8657, Japan.
| | - Kazuki Kubota
- Department of Applied Biological Chemistry, Graduate School of Agricultural and Life Sciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo-ku, Tokyo 113-8657, Japan
| | - Ryo Nishimura
- Department of Applied Biological Chemistry, Graduate School of Agricultural and Life Sciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo-ku, Tokyo 113-8657, Japan
| | - Lumi Negishi
- Institute for Quantitative Biosciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo-ku, Tokyo 113-8657, Japan
| | - Kazuki Komatsu
- Geochemical Research Center, Graduate School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
| | - Hioryuki Kagi
- Geochemical Research Center, Graduate School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
| | - Katya Rehav
- Department of Structural Biology, Weizmann Institute of Science, Rehovot, Israel
| | - Sidney Cohen
- Department of Chemical Research Support, Weizmann Institute of Science, Rehovot, Israel
| | - Steve Weiner
- Department of Structural Biology, Weizmann Institute of Science, Rehovot, Israel
| |
Collapse
|
15
|
Lim WL, Liau LL, Ng MH, Chowdhury SR, Law JX. Current Progress in Tendon and Ligament Tissue Engineering. Tissue Eng Regen Med 2019; 16:549-571. [PMID: 31824819 PMCID: PMC6879704 DOI: 10.1007/s13770-019-00196-w] [Citation(s) in RCA: 97] [Impact Index Per Article: 19.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 05/07/2019] [Accepted: 05/22/2019] [Indexed: 02/08/2023] Open
Abstract
Background Tendon and ligament injuries accounted for 30% of all musculoskeletal consultations with 4 million new incidences worldwide each year and thus imposed a significant burden to the society and the economy. Damaged tendon and ligament can severely affect the normal body movement and might lead to many complications if not treated promptly and adequately. Current conventional treatment through surgical repair and tissue graft are ineffective with a high rate of recurrence. Methods In this review, we first discussed the anatomy, physiology and pathophysiology of tendon and ligament injuries and its current treatment. Secondly, we explored the current role of tendon and ligament tissue engineering, describing its recent advances. After that, we also described stem cell and cell secreted product approaches in tendon and ligament injuries. Lastly, we examined the role of the bioreactor and mechanical loading in in vitro maturation of engineered tendon and ligament. Results Tissue engineering offers various alternative ways of treatment from biological tissue constructs to stem cell therapy and cell secreted products. Bioreactor with mechanical stimulation is instrumental in preparing mature engineered tendon and ligament substitutes in vitro. Conclusions Tissue engineering showed great promise in replacing the damaged tendon and ligament. However, more study is needed to develop ideal engineered tendon and ligament.
Collapse
Affiliation(s)
- Wei Lee Lim
- Tissue Engineering Centre, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, Jalan Yaacob Latif, 56000 Kuala Lumpur, Malaysia
| | - Ling Ling Liau
- Department of Physiology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, JalanYaacob Latif, 56000 Kuala Lumpur, Malaysia
| | - Min Hwei Ng
- Tissue Engineering Centre, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, Jalan Yaacob Latif, 56000 Kuala Lumpur, Malaysia
| | - Shiplu Roy Chowdhury
- Tissue Engineering Centre, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, Jalan Yaacob Latif, 56000 Kuala Lumpur, Malaysia
| | - Jia Xian Law
- Tissue Engineering Centre, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Centre, Jalan Yaacob Latif, 56000 Kuala Lumpur, Malaysia
| |
Collapse
|
16
|
Abstract
Natural creatures, from fish and cephalopods to snakes and birds, combine neural control, sensory feedback and compliant mechanics to effectively operate across dynamic, uncertain environments. In order to facilitate the understanding of the biophysical mechanisms at play and to streamline their potential use in engineering applications, we present here a versatile numerical approach to the simulation of musculoskeletal architectures. It relies on the assembly of heterogenous, active and passive Cosserat rods into dynamic structures that model bones, tendons, ligaments, fibers and muscle connectivity. We demonstrate its utility in a range of problems involving biological and soft robotic scenarios across scales and environments: from the engineering of millimeter-long bio-hybrid robots to the synthesis and reconstruction of complex musculoskeletal systems. The versatility of this methodology offers a framework to aid forward and inverse bioengineering designs as well as fundamental discovery in the functioning of living organisms.
Collapse
Affiliation(s)
- Xiaotian Zhang
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Fan Kiat Chan
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Tejaswin Parthasarathy
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Mattia Gazzola
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- National Center for Supercomputing Applications, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
| |
Collapse
|
17
|
Hamdia KM, Marino M, Zhuang X, Wriggers P, Rabczuk T. Sensitivity analysis for the mechanics of tendons and ligaments: Investigation on the effects of collagen structural properties via a multiscale modeling approach. Int J Numer Method Biomed Eng 2019; 35:e3209. [PMID: 30989796 DOI: 10.1002/cnm.3209] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Revised: 04/09/2019] [Accepted: 04/10/2019] [Indexed: 06/09/2023]
Abstract
The effects of the stochasticity of collagen-related structural properties on the biomechanical properties of tendons and ligaments are investigated in this study. The tissue mechanics is modeled by means of a macroscale constitutive model based on a multiscale structural approach. This rationale allows to introduce model parameters directly associated with tissue structural and biochemical features, opening to physically motivated parametric studies. Variance and density-based global sensitivity analyses are employed, together with the quantification of output uncertainty due to stochastic variations of parameters. Novel insights on tissue structure-mechanics relationship are provided, quantifying the dependence between mechanical output quantities on specific collagen-related structural features. Moreover, the uncertainty quantification shows that model predictions provided by the multiscale structural approach are reliable with respect to inevitable uncertainties in tissue structure. Addressing rat tail tendons, the use of average values in tissue properties returns a constitutive response that fits well-available experimental data, and it is robust with respect to parameter stochasticity.
Collapse
Affiliation(s)
- Khader M Hamdia
- Division of Computational Mechanics, Ton Duc Thang University, Ho Chi Minh City, Vietnam
- Faculty of Civil Engineering, Ton Duc Thang University, Ho Chi Minh City, Vietnam
| | - Michele Marino
- Institute of Continuum Mechanics, Leibniz Universit.t Hannover, Hannover, Germany
| | - Xiaoying Zhuang
- Division of Computational Mechanics, Ton Duc Thang University, Ho Chi Minh City, Vietnam
- Faculty of Civil Engineering, Ton Duc Thang University, Ho Chi Minh City, Vietnam
| | - Peter Wriggers
- Institute of Continuum Mechanics, Leibniz Universit.t Hannover, Hannover, Germany
| | - Timon Rabczuk
- Department of Geotechnical Engineering, College of Civil Engineering, Tongji University, Shanghai, China
| |
Collapse
|
18
|
Mazumder O, Chakravarty K, Chatterjee D, Sinha A, Poduval M. Musculoskeletal modeling to predict and reduce Antetrior Cruciate Ligament injury during single leg drop jump activity: Synergistic muscle co-activation approach. Annu Int Conf IEEE Eng Med Biol Soc 2019; 2019:4108-4112. [PMID: 31946774 DOI: 10.1109/embc.2019.8856321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
This paper presents a `drop jump' modeling to study the effect of synergistic muscle activation on controlling Anterior Cruciate Ligament (ACL) injury. ACL injuries are mostly caused during high impact loading. A full body musculoskeletal model with knee ligaments have been developed in `OpenSim platform' to simulate ACL injury during drop jump activity. The model is used to quantify the effect of change in muscle activation on different kinetic and kinematic parameters, which are associated with ACL injury. A neuromusculoskeletal controller have been designed which selects optimal muscle activation of Quadriceps, Hamstrings, Gastrocnemius and Tibilias anterior muscle group so as to reduce the chance of ACL injury and ankle inversion risk while jumping from elevated platforms. The OpenSim model along with the neuro-muscular controller forms an injury `predict-adapt' system, which can be useful in designing specific training sessions for athletics or for planning personalized rehabilitation therapy.
Collapse
|
19
|
Liu A, Ingham E, Fisher J, Jennings LM. Development of a pre-clinical experimental simulation model of the natural porcine knee with appropriate ligamentous constraints. PLoS One 2019; 14:e0216872. [PMID: 31086417 PMCID: PMC6516662 DOI: 10.1371/journal.pone.0216872] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Accepted: 04/18/2019] [Indexed: 11/18/2022] Open
Abstract
A robust and stratified pre-clinical natural knee model, which has the capability to more appropriately simulate the biomechanical environment in vivo, will deliver more efficient and reliable assessment of soft tissue interventions before clinical studies. In order to simulate the biomechanical function of the natural knee without the natural ligaments in place, there is a requirement to develop appropriate spring constraints for the natural knee model. Therefore, this study was to investigate the effect of spring constraints on the function and output of the natural porcine knee model, and determine the spring constraint which most closely replicated the function of the natural ligaments. Two linear compression springs with stiffnesses of 9 N/mm (spring-9) and 20 N/mm (spring-20) were set at different free lengths in the anterior-posterior (A/P) axis in a natural knee simulator. The kinematic (A/P displacement) and tribological properties (shear force) output of the simulator were compared at different spring settings. The most appropriate spring setting was determined by comparing the A/P displacement and shear force output at different spring settings with those of the all ligaments model. Spring-9 with a free length of 4 mm showed the minimal difference (-0.03±0.68 mm) in A/P displacement output and spring-20 with a free length of 5 mm showed the minimal difference (-0.10±0.73 mm) in A/P displacement output compared to the all ligament control. There was no statistical difference between the two minimal differences either in A/P displacement or in shear force (paired t-test, p = 0.58, and p = 0.68 respectively) when both spring settings matched most closely to the A/P kinematics of the intact knee. This indicated that both conditions were appropriate spring constraints settings in the A/P direction for the natural porcine knee model.
Collapse
Affiliation(s)
- Aiqin Liu
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, Faculty of Engineering, University of Leeds, Leeds, United Kingdom
| | - Eileen Ingham
- Institute of Medical and Biological Engineering, School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| | - John Fisher
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, Faculty of Engineering, University of Leeds, Leeds, United Kingdom
| | - Louise M. Jennings
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, Faculty of Engineering, University of Leeds, Leeds, United Kingdom
| |
Collapse
|
20
|
Beidokhti HN, Janssen D, van de Groes S, Verdonschot N. The peripheral soft tissues should not be ignored in the finite element models of the human knee joint. Med Biol Eng Comput 2018; 56:1189-1199. [PMID: 29214465 PMCID: PMC6013543 DOI: 10.1007/s11517-017-1757-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Accepted: 11/20/2017] [Indexed: 01/14/2023]
Abstract
In finite element models of the either implanted or intact human knee joint, soft tissue structures like tendons and ligaments are being incorporated, but usually skin, peripheral knee soft tissues, and the posterior capsule are ignored and assumed to be of minor influence on knee joint biomechanics. It is, however, unknown how these peripheral structures influence the biomechanical response of the knee. In this study, the aim was to assess the significance of the peripheral soft tissues and posterior capsule on the kinematics and laxities of human knee joint, based on experimental tests on three human cadaveric specimens. Despite the high inter-subject variability of the results, it was demonstrated that the target tissues have a considerable influence on posterior translational and internal and valgus rotational laxities of lax knees under flexion. Consequently, ignoring these tissues from computational models may alter the knee joint biomechanics.
Collapse
Affiliation(s)
- Hamid Naghibi Beidokhti
- Orthopedic Research Laboratory, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 GA, Nijmegen, The Netherlands.
| | - Dennis Janssen
- Orthopedic Research Laboratory, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 GA, Nijmegen, The Netherlands
| | | | - Nico Verdonschot
- Orthopedic Research Laboratory, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 GA, Nijmegen, The Netherlands
- Laboratory of Biomechanical Engineering, University of Twente, Enschede, The Netherlands
| |
Collapse
|
21
|
Hanot P, Herrel A, Guintard C, Cornette R. The impact of artificial selection on morphological integration in the appendicular skeleton of domestic horses. J Anat 2018; 232:657-673. [PMID: 29315551 PMCID: PMC5835793 DOI: 10.1111/joa.12772] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/04/2017] [Indexed: 01/12/2023] Open
Abstract
The relationships between the different component parts of organisms, such as the sharing of common development or function, produce a coordinated variation between the different traits. This morphological integration contributes to drive or constrain morphological variation and thus impacts phenotypic diversification. Artificial selection is known to contribute significantly to phenotypic diversification of domestic species. However, little attention has been paid to its potential impact on integration patterns. This study explores the patterns of integration in the limb bones of different horse breeds, using 3D geometric morphometrics. The domestic horse is known to have been strongly impacted by artificial selection, and was often selected for functional traits. Our results confirm that morphological integration among bones within the same limb is strong and apparently partly produced by functional factors. Most importantly, they reveal that artificial selection, which led to the diversification of domestic horses, impacts covariation patterns. The influence of selection on the patterns of covariation varies along the limbs and modulates bone shape, likely due to a differential ligament or muscle development. These results highlight that, in addition to not being constrained by a strong morphological integration, artificial selection has modulated the covariation patterns according to the locomotor specificities of the breeds. More broadly, it illustrates the interest in studying how micro-evolutionary processes impact covariation patterns and consequently contribute to morphological diversification of domestic species.
Collapse
Affiliation(s)
- Pauline Hanot
- UMR 7209 Archéozoologie et Archéobotanique: Sociétés, Pratiques et Environnements (CNRS, MNHN)Muséum national d'Histoire naturelleSorbonne UniversitésParisFrance
| | - Anthony Herrel
- UMR 7179 Mécanismes Adaptatifs et Évolution (CNRS, MNHN)Muséum national d'Histoire naturelleSorbonne UniversitésParisFrance
| | - Claude Guintard
- École Nationale Vétérinaire, de l'Agroalimentaire et de l'AlimentationNantes Atlantique – ONIRISNantes Cedex 03France
| | - Raphaël Cornette
- UMR 7205 Institut de Systématique, Évolution, Biodiversité (CNRS, MNHN, UPMC, EPHE)Muséum national d'Histoire naturelleSorbonne UniversitésParisFrance
| |
Collapse
|
22
|
Patel S, Caldwell JM, Doty SB, Levine WN, Rodeo S, Soslowsky LJ, Thomopoulos S, Lu HH. Integrating soft and hard tissues via interface tissue engineering. J Orthop Res 2018; 36:1069-1077. [PMID: 29149506 PMCID: PMC6467291 DOI: 10.1002/jor.23810] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2017] [Accepted: 10/21/2017] [Indexed: 02/04/2023]
Abstract
The enthesis, or interface between bone and soft tissues such as ligament and tendon, is prone to injury and often does not heal, even post surgical intervention. Interface tissue engineering represents an integrative strategy for regenerating the native enthesis by functionally connecting soft and hard tissues and thereby improving clinical outcome. This review focuses on integrative and cell-instructive scaffold designs that target the healing of the two most commonly injured soft tissue-bone junctions: tendon-bone interface (e.g., rotator cuff) and ligament-bone interface (e.g., anterior cruciate ligament). The inherent connectivity between soft and hard tissues is instrumental for musculoskeletal motion and is therefore a key design criterion for soft tissue regeneration. To this end, scaffold design for soft tissue regeneration have progressed from single tissue systems to the emerging focus on pre-integrated and functional composite tissue units. Specifically, a multifaceted, bioinspired approach has been pursued wherein scaffolds are tailored to stimulate relevant cell responses using spatially patterned structural and chemical cues, growth factors, and/or mechanical stimulation. Moreover, current efforts to elucidate the essential scaffold design criteria via strategic biomimicry are emphasized as these will reduce complexity in composite tissue regeneration and ease the related burden for clinical translation. These innovative studies underscore the clinical relevance of engineering connective tissue integration and have broader impact in the formation of complex tissues and total joint regeneration. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1069-1077, 2018.
Collapse
Affiliation(s)
- Sahishnu Patel
- Biomaterials and Interface Tissue Engineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, New York 10027
| | - Jon-Michael Caldwell
- Department of Orthopedic Surgery, New York Presbyterian/Columbia University Medical Center, New York, New York 10032
| | - Stephen B. Doty
- Analytical Microscopy Core Laboratory, Hospital for Special Surgery, New York, New York 10021
| | - William N. Levine
- Department of Orthopedic Surgery, New York Presbyterian/Columbia University Medical Center, New York, New York 10032
| | - Scott Rodeo
- Soft Tissue Research Laboratory, Hospital for Special Surgery, New York, New York 10021
| | - Louis J. Soslowsky
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, Pennsylvania 19104
| | - Stavros Thomopoulos
- Carroll Laboratories of Orthopedic Research, Department of Orthopedic Surgery, Columbia University, New York, New York 10032
| | - Helen H. Lu
- Biomaterials and Interface Tissue Engineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, New York 10027
| |
Collapse
|
23
|
Karunaratne A, Li S, Bull AMJ. Nano-scale mechanisms explain the stiffening and strengthening of ligament tissue with increasing strain rate. Sci Rep 2018; 8:3707. [PMID: 29487334 PMCID: PMC5829138 DOI: 10.1038/s41598-018-21786-z] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 02/10/2018] [Indexed: 11/08/2022] Open
Abstract
Ligament failure is a major societal burden causing disability and pain. Failure is caused by trauma at high loading rates. At the macroscopic level increasing strain rates cause an increase in failure stress and modulus, but the mechanism for this strain rate dependency is not known. Here we investigate the nano scale mechanical property changes of human ligament using mechanical testing combined with synchrotron X-ray diffraction. With increasing strain rate, we observe a significant increase in fibril modulus and a reduction of fibril to tissue strain ratio, revealing that tissue-level stiffening is mainly due to the stiffening of collagen fibrils. Further, we show that the reduction in fibril deformation at higher strain rates is due to reduced molecular strain and fibrillar gaps, and is associated with rapid disruption of matrix-fibril bonding. This reduction in number of interfibrillar cross-links explains the changes in fibril strain; this is verified through computational modelling.
Collapse
Affiliation(s)
- Angelo Karunaratne
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
- Department of Mechanical Engineering, University of Moratuwa, Moratuwa, Sri Lanka
| | - Simin Li
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, UK
| | - Anthony M J Bull
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK.
| |
Collapse
|
24
|
Russell F, Gao L, Ellison P, Vaidyanathan R. Challenges in using compliant ligaments for position estimation within robotic joints. IEEE Int Conf Rehabil Robot 2017; 2017:1471-1476. [PMID: 28814027 DOI: 10.1109/icorr.2017.8009455] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The mechanical advantages of bio-inspired condylar robotic knee joints for use in prosthetics or rehabilitation has been argued extensively in literature. A common limitation of these designs is the difficulty of estimating joint angle and therefore accurately controlling the joint. Furthermore, the potential role of ligament-like structures in robotic knees is not very well established. In this work, we investigate the role of compliant stretch sensing ligaments and their integration into a condylar robotic knee. Simulations and experiments are executed out in order to establish whether measurement of stretch in these structures can be used to produce a new feedback controller for joint position. We report results from a computer model, as well as the design and construction of a robotic knee that show, for a chosen condyle shape, ligament stretch is a function of muscle force and joint velocity as well as joint angle. We have developed a genetic algorithm optimised controller incorporating ligament feedback that demonstrates improved performance for a desired joint angle in response to step inputs. The controller showed marginal improvement in response to a cyclic command signal and further investigation is required in order to use these measurements in robust control, nevertheless we believe these results demonstrate the that ligament-like structures have the potential to improve the performance of robotic knees for prosthetics and rehabilitation devices.
Collapse
|
25
|
Ifegwu OC, Awale G, Rajpura K, Lo KWH, Laurencin CT. Harnessing cAMP signaling in musculoskeletal regenerative engineering. Drug Discov Today 2017; 22:1027-1044. [PMID: 28359841 PMCID: PMC7440772 DOI: 10.1016/j.drudis.2017.03.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Revised: 03/08/2017] [Accepted: 03/20/2017] [Indexed: 01/28/2023]
Abstract
This paper reviews the most recent findings in the search for small molecule cyclic AMP analogues regarding their potential use in musculoskeletal regenerative engineering.
Collapse
Affiliation(s)
- Okechukwu Clinton Ifegwu
- Institute for Regenerative Engineering, University of Connecticut Health Center, School of Medicine, Farmington, CT 06030, USA; The Raymond and Beverly Sackler Center for Biomedical, Biological, Physical and Engineering Sciences, University of Connecticut Health Center, School of Medicine, Farmington, CT 06030, USA; Department of Orthopedic Surgery, University of Connecticut Health Center, Farmington, CT 06030, USA
| | - Guleid Awale
- Institute for Regenerative Engineering, University of Connecticut Health Center, School of Medicine, Farmington, CT 06030, USA; The Raymond and Beverly Sackler Center for Biomedical, Biological, Physical and Engineering Sciences, University of Connecticut Health Center, School of Medicine, Farmington, CT 06030, USA; Department of Chemical and Biomolecular Engineering, University of Connecticut, School of Engineering, Storrs, CT 06030, USA
| | - Komal Rajpura
- Institute for Regenerative Engineering, University of Connecticut Health Center, School of Medicine, Farmington, CT 06030, USA; The Raymond and Beverly Sackler Center for Biomedical, Biological, Physical and Engineering Sciences, University of Connecticut Health Center, School of Medicine, Farmington, CT 06030, USA; Connecticut Institute for Clinical and Translational Science, University of Connecticut Health Center, Farmington, CT 06030, USA
| | - Kevin W-H Lo
- Institute for Regenerative Engineering, University of Connecticut Health Center, School of Medicine, Farmington, CT 06030, USA; The Raymond and Beverly Sackler Center for Biomedical, Biological, Physical and Engineering Sciences, University of Connecticut Health Center, School of Medicine, Farmington, CT 06030, USA; Department of Orthopedic Surgery, University of Connecticut Health Center, Farmington, CT 06030, USA; Connecticut Institute for Clinical and Translational Science, University of Connecticut Health Center, Farmington, CT 06030, USA; UConn Stem Cell Institute, University of Connecticut Health Center, Farmington, CT 06030, USA; Department of Biomedical Engineering, University of Connecticut, School of Engineering, Storrs, CT 06268, USA
| | - Cato T Laurencin
- Institute for Regenerative Engineering, University of Connecticut Health Center, School of Medicine, Farmington, CT 06030, USA; The Raymond and Beverly Sackler Center for Biomedical, Biological, Physical and Engineering Sciences, University of Connecticut Health Center, School of Medicine, Farmington, CT 06030, USA; Department of Orthopedic Surgery, University of Connecticut Health Center, Farmington, CT 06030, USA; Connecticut Institute for Clinical and Translational Science, University of Connecticut Health Center, Farmington, CT 06030, USA; Department of Medicine, Division of Endocrinology, University of Connecticut Health Center, School of Medicine, Farmington, CT 06030, USA; UConn Stem Cell Institute, University of Connecticut Health Center, Farmington, CT 06030, USA; Department of Biomedical Engineering, University of Connecticut, School of Engineering, Storrs, CT 06268, USA.
| |
Collapse
|
26
|
Shukunami C. [Integration of the musculoskeletal components by tendons and ligaments.]. Clin Calcium 2017; 27:367-373. [PMID: 28232651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Tendons transmit the mechanical force of skeletal muscle contraction to the bones, whereas ligaments connect the two bones together to stabilize the joint. During embryonic development, each component in the musculoskeletal system, initially develops as an individual primordium of tendon, ligament, skeletal muscle, and cartilage. Later, mutual interaction between these tissues plays an important role for the integration of the musculoskeletal components. Accumulating evidence suggests that myotendinous and osteotendinous/osteoligamentous junctions are important structures to maintain homeostasis of the integrated musculoskeletal components. In this review, we will focus on the establishment and maintenance of these junctions.
Collapse
Affiliation(s)
- Chisa Shukunami
- Department of Molecular Biology and Biochemistry, Basic Life Sciences, Institute of Biomedical and Health Sciences, Hiroshima University, Japan
| |
Collapse
|
27
|
Ma ZJ, Bai LP, Zeng XS, Ya J, Wang QG. [Biomechanics and imaging evaluation on stable structure of pelvis]. Zhongguo Gu Shang 2016; 29:1164-1168. [PMID: 29292897 DOI: 10.3969/j.issn.1003-0034.2016.12.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 02/29/2016] [Indexed: 06/07/2023]
Abstract
The treatment of difficulty and prognosis of pelvic fracture are directly related to the pelvic girdle stability. Diagnosis of pelvic fracture is mainly imaging manifestations based on biomechanics of pelvic anatomy. With the progress of biomechanics experiment technology, previousopinion has changed, such as separation of symphysis pubis 2.5 cm could not be seen as distinguishing feature of type I and II for anterior-posterior compression;displacement of sacroilliac joints less than 1 cm could cause loss of vertical stability;lateral extrusion could also cause vertical instability;part description of Young-Burgess classification is not suitable for experiment results;ligament plays an important role in restricting displacement and having proprioceptors;SPECT-CT could improve sensitivity of diagnosis, but could not evaluate stability of pelvic fractures precisely.
Collapse
Affiliation(s)
| | | | | | | | - Qiu-Gen Wang
- Department of Trauma Orthopaedics, Shanghai General Hospital of Nanjing Medical University, Shanghai 201620, China;
| |
Collapse
|
28
|
Östh J, Brolin K, Svensson MY, Linder A. A Female Ligamentous Cervical Spine Finite Element Model Validated for Physiological Loads. J Biomech Eng 2016; 138:061005. [PMID: 26974520 DOI: 10.1115/1.4032966] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Indexed: 11/08/2022]
Abstract
Mathematical cervical spine models allow for studying of impact loading that can cause whiplash associated disorders (WAD). However, existing models only cover the male anthropometry, despite the female population being at a higher risk of sustaining WAD in automotive rear-end impacts. The aim of this study is to develop and validate a ligamentous cervical spine intended for biomechanical research on the effect of automotive impacts. A female model has the potential to aid the design of better protection systems as well as improve understanding of injury mechanisms causing WAD. A finite element (FE) mesh was created from surface data of the cervical vertebrae of a 26-year old female (stature 167 cm, weight 59 kg). Soft tissues were generated from the skeletal geometry and anatomical literature descriptions. Ligaments were modeled with nonlinear elastic orthotropic membrane elements, intervertebral disks as composites of nonlinear elastic bulk elements, and orthotropic anulus fibrosus fiber layers, while cortical and trabecular bones were modeled as isotropic plastic-elastic. The model has geometrical features representative of the female cervical spine-the largest average difference compared with published anthropometric female data was the vertebral body depth being 3.4% shorter for the model. The majority the cervical segments compare well with respect to biomechanical data at physiological loads, with the best match for flexion-extension loads and less biofidelity for axial rotation. An average female FE ligamentous cervical spine model was developed and validated with respect to physiological loading. In flexion-extension simulations with the developed female model and an existing average male cervical spine model, a greater range of motion (ROM) was found in the female model.
Collapse
|
29
|
Kia M, Schafer K, Lipman J, Cross M, Mayman D, Pearle A, Wickiewicz T, Imhauser C. A Multibody Knee Model Corroborates Subject-Specific Experimental Measurements of Low Ligament Forces and Kinematic Coupling During Passive Flexion. J Biomech Eng 2016; 138:051010. [PMID: 26926010 DOI: 10.1115/1.4032850] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2015] [Indexed: 11/08/2022]
Abstract
A multibody model of the knee was developed and the predicted ligament forces and kinematics during passive flexion corroborated subject-specific measurements obtained from a human cadaveric knee that was tested using a robotic manipulator. The model incorporated a novel strategy to estimate the slack length of ligament fibers based on experimentally measured ligament forces at full extension and included multifiber representations for the cruciates. The model captured experimentally measured ligament forces (≤ 5.7 N root mean square (RMS) difference), coupled internal rotation (≤ 1.6 deg RMS difference), and coupled anterior translation (≤ 0.4 mm RMS difference) through 130 deg of passive flexion. This integrated framework of model and experiment improves our understanding of how passive structures, such as ligaments and articular geometries, interact to generate knee kinematics and ligament forces.
Collapse
|
30
|
Smith CR, Vignos MF, Lenhart RL, Kaiser J, Thelen DG. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement. J Biomech Eng 2016; 138:021017. [PMID: 26769446 DOI: 10.1115/1.4032464] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2015] [Indexed: 11/08/2022]
Abstract
The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial-lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and -23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement.
Collapse
|
31
|
Zhang S, Cao X, Stablow AM, Shenoy VB, Winkelstein BA. Tissue Strain Reorganizes Collagen With a Switchlike Response That Regulates Neuronal Extracellular Signal-Regulated Kinase Phosphorylation In Vitro: Implications for Ligamentous Injury and Mechanotransduction. J Biomech Eng 2016; 138:021013. [PMID: 26549105 DOI: 10.1115/1.4031975] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2015] [Indexed: 12/26/2022]
Abstract
Excessive loading of ligaments can activate the neural afferents that innervate the collagenous tissue, leading to a host of pathologies including pain. An integrated experimental and modeling approach was used to define the responses of neurons and the surrounding collagen fibers to the ligamentous matrix loading and to begin to understand how macroscopic deformation is translated to neuronal loading and signaling. A neuron-collagen construct (NCC) developed to mimic innervation of collagenous tissue underwent tension to strains simulating nonpainful (8%) or painful ligament loading (16%). Both neuronal phosphorylation of extracellular signal-regulated kinase (ERK), which is related to neuroplasticity (R2 ≥ 0.041; p ≤ 0.0171) and neuronal aspect ratio (AR) (R2 ≥ 0.250; p < 0.0001), were significantly correlated with tissue-level strains. As NCC strains increased during a slowly applied loading (1%/s), a "switchlike" fiber realignment response was detected with collagen reorganization occurring only above a transition point of 11.3% strain. A finite-element based discrete fiber network (DFN) model predicted that at bulk strains above the transition point, heterogeneous fiber strains were both tensile and compressive and increased, with strains in some fibers along the loading direction exceeding the applied bulk strain. The transition point identified for changes in collagen fiber realignment was consistent with the measured strain threshold (11.7% with a 95% confidence interval of 10.2-13.4%) for elevating ERK phosphorylation after loading. As with collagen fiber realignment, the greatest degree of neuronal reorientation toward the loading direction was observed at the NCC distraction corresponding to painful loading. Because activation of neuronal ERK occurred only at strains that produced evident collagen fiber realignment, findings suggest that tissue strain-induced changes in the micromechanical environment, especially altered local collagen fiber kinematics, may be associated with mechanotransduction signaling in neurons.
Collapse
|
32
|
Chen H, Zhao X, Berwick ZC, Krieger JF, Chambers S, Kassab GS. Microstructure and Mechanical Property of Glutaraldehyde-Treated Porcine Pulmonary Ligament. J Biomech Eng 2016; 138:061003. [PMID: 27040732 DOI: 10.1115/1.4033300] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2015] [Indexed: 01/15/2023]
Abstract
There is a significant need for fixed biological tissues with desired structural and material constituents for tissue engineering applications. Here, we introduce the lung ligament as a fixed biological material that may have clinical utility for tissue engineering. To characterize the lung tissue for potential clinical applications, we studied glutaraldehyde-treated porcine pulmonary ligament (n = 11) with multiphoton microscopy (MPM) and conducted biaxial planar experiments to characterize the mechanical property of the tissue. The MPM imaging revealed that there are generally two families of collagen fibers distributed in two distinct layers: The first family largely aligns along the longitudinal direction with a mean angle of θ = 10.7 ± 9.3 deg, while the second one exhibits a random distribution with a mean θ = 36.6 ± 27.4. Elastin fibers appear in some intermediate sublayers with a random orientation distribution with a mean θ = 39.6 ± 23 deg. Based on the microstructural observation, a microstructure-based constitutive law was proposed to model the elastic property of the tissue. The material parameters were identified by fitting the model to the biaxial stress-strain data of specimens, and good fitting quality was achieved. The parameter e0 (which denotes the strain beyond which the collagen can withstand tension) of glutaraldehyde-treated tissues demonstrated low variability implying a relatively consistent collagen undulation in different samples, while the stiffness parameters for elastin and collagen fibers showed relatively greater variability. The fixed tissues presented a smaller e0 than that of fresh specimen, confirming that glutaraldehyde crosslinking increases the mechanical strength of collagen-based biomaterials. The present study sheds light on the biomechanics of glutaraldehyde-treated porcine pulmonary ligament that may be a candidate for tissue engineering.
Collapse
|
33
|
Affiliation(s)
- Moisés Rodríguez-Mañero
- Methodist DeBakey Heart and Vascular Center and Methodist Hospital Research Institute, The Methodist Hospital, Houston, Texas
| | - Paul Schurmann
- Methodist DeBakey Heart and Vascular Center and Methodist Hospital Research Institute, The Methodist Hospital, Houston, Texas
| | - Miguel Valderrábano
- Methodist DeBakey Heart and Vascular Center and Methodist Hospital Research Institute, The Methodist Hospital, Houston, Texas.
| |
Collapse
|
34
|
Spinella G, Loprete G, Castagnetti C, Musella V, Antonelli C, Vilar JM, Britti D, Capitani O, Valentini S. Evaluation of mean echogenicity of tendons and ligaments of the metacarpal region in neonatal foals: A preliminary study. Res Vet Sci 2015; 101:11-4. [PMID: 26267082 DOI: 10.1016/j.rvsc.2015.05.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2014] [Revised: 04/20/2015] [Accepted: 05/19/2015] [Indexed: 11/18/2022]
Abstract
The aims of this research were to evaluate mean echogenicity (ME) of the deep and superficial digital flexor tendons (DDFT and SDFT), the interosseous muscle (IM), and the accessory ligament of the deep digital flexor tendon (ALDDFT) of the metacarpal region in neonatal foals, and determine the effect of sex, side and body weight on this quantitative ultrasonographic evaluation. Thirteen orthopedically sound neonatal foals were examined. Four areas of study (1A, 1B, 2A, 2B) were identified. Transverse scans of the DDFT, SDFT, IM and ALDDFT were obtained, recorded, and analyzed. The most echogenic structures were the ALDDFT and DDFT, while the SDFT was significantly less echogenic than all other structures (P<0.05). No influence of sex, forelimb, or body weight was observed. The echogenicity of the tenodesmic structures of foals partially overlapped that reported in the metacarpal region in adult horses, except for IM.
Collapse
Affiliation(s)
- G Spinella
- Department of Veterinary Medical Sciences, University of Bologna, Ozzano dell'Emilia, BO, Italy.
| | - G Loprete
- Department of Health Sciences, University Magna Graecia of Catanzaro, 88100 Germaneto, CZ, Italy
| | - C Castagnetti
- Department of Veterinary Medical Sciences, University of Bologna, Ozzano dell'Emilia, BO, Italy
| | - V Musella
- Department of Health Sciences, University Magna Graecia of Catanzaro, 88100 Germaneto, CZ, Italy
| | - C Antonelli
- Department of Veterinary Medical Sciences, University of Bologna, Ozzano dell'Emilia, BO, Italy
| | - J M Vilar
- Department of Animal Pathology, Faculty of Veterinary Medicine, University of Las Palmas de Gran Canaria, Trasmontaña S/N, Arucas 35413, Las Palmas, Spain
| | - D Britti
- Department of Health Sciences, University Magna Graecia of Catanzaro, 88100 Germaneto, CZ, Italy
| | - O Capitani
- Department of Veterinary Medical Sciences, University of Bologna, Ozzano dell'Emilia, BO, Italy
| | - S Valentini
- Department of Veterinary Medical Sciences, University of Bologna, Ozzano dell'Emilia, BO, Italy
| |
Collapse
|
35
|
Wilkie IC, Fassini D, Cullorà E, Barbaglio A, Tricarico S, Sugni M, Del Giacco L, Candia Carnevali MD. Mechanical properties of the compass depressors of the sea-urchin Paracentrotus lividus (Echinodermata, Echinoidea) and the effects of enzymes, neurotransmitters and synthetic tensilin-like protein. PLoS One 2015; 10:e0120339. [PMID: 25786033 PMCID: PMC4365025 DOI: 10.1371/journal.pone.0120339] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2014] [Accepted: 01/22/2015] [Indexed: 01/08/2023] Open
Abstract
The compass depressors (CDs) of the sea-urchin lantern are ligaments consisting mainly of discontinuous collagen fibrils associated with a small population of myocytes. They are mutable collagenous structures, which can change their mechanical properties rapidly and reversibly under nervous control. The aims of this investigation were to characterise the baseline (i.e. unmanipulated) static mechanical properties of the CDs of Paracentrotus lividus by means of creep tests and incremental force-extension tests, and to determine the effects on their mechanical behaviour of a range of agents. Under constant load the CDs exhibited a three-phase creep curve, the mean coefficient of viscosity being 561±365 MPa.s. The stress-strain curve showed toe, linear and yield regions; the mean strain at the toe-linear inflection was 0.86±0.61; the mean Young's modulus was 18.62±10.30 MPa; and the mean tensile strength was 8.14±5.73 MPa. Hyaluronidase from Streptomyces hyalurolyticus had no effect on creep behaviour, whilst chondroitinase ABC prolonged primary creep but had no effect on secondary creep or on any force-extension parameters; it thus appears that neither hyaluronic acid nor sulphated glycosaminoglycans have an interfibrillar load transfer function in the CD. Acetylcholine, the muscarinic agonists arecoline and methacholine, and the nicotinic agonists nicotine and 1-[1-(3,4-dimethyl-phenyl)-ethyl]-piperazine produced an abrupt increase in CD viscosity; the CDs were not differentially sensitive to muscarinic or nicotinic agonists. CDs showed either no, or no consistent, response to adrenaline, L-glutamic acid, 5-hydroxytryptamine and γ-aminobutyric acid. Synthetic echinoid tensilin-like protein had a weak and inconsistent stiffening effect, indicating that, in contrast to holothurian tensilins, the echinoid molecule may not be involved in the regulation of collagenous tissue tensility. We compare in detail the mechanical behaviour of the CD with that of mammalian tendon and highlight its potential as a model system for investigating poorly understood aspects of the ontogeny and phylogeny of vertebrate collagenous tissues.
Collapse
Affiliation(s)
- Iain C. Wilkie
- Department of Life Sciences, Glasgow Caledonian University, Glasgow, Scotland, United Kingdom
| | - Dario Fassini
- Dipartimento di Bioscienze, Università degli Studi di Milano, Milano, Italy
| | - Emanuele Cullorà
- Dipartimento di Bioscienze, Università degli Studi di Milano, Milano, Italy
| | - Alice Barbaglio
- Dipartimento di Bioscienze, Università degli Studi di Milano, Milano, Italy
| | - Serena Tricarico
- Dipartimento di Bioscienze, Università degli Studi di Milano, Milano, Italy
| | - Michela Sugni
- Dipartimento di Bioscienze, Università degli Studi di Milano, Milano, Italy
| | - Luca Del Giacco
- Dipartimento di Bioscienze, Università degli Studi di Milano, Milano, Italy
| | | |
Collapse
|
36
|
Heidari Pahlavian S, Bunck AC, Loth F, Shane Tubbs R, Yiallourou T, Kroeger JR, Heindel W, Martin BA. Characterization of the discrepancies between four-dimensional phase-contrast magnetic resonance imaging and in-silico simulations of cerebrospinal fluid dynamics. J Biomech Eng 2015; 137:051002. [PMID: 25647090 DOI: 10.1115/1.4029699] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2014] [Indexed: 02/05/2023]
Abstract
The purpose of the present study was to compare subject-specific magnetic resonance imaging (MRI)-based computational fluid dynamics (CFD) simulations with time-resolved three-directional (3D) velocity-encoded phase-contrast MRI (4D PCMRI) measurements of the cerebrospinal fluid (CSF) velocity field in the cervical spinal subarachnoid space (SSS). Three-dimensional models of the cervical SSS were constructed based on MRI image segmentation and anatomical measurements for a healthy subject and patient with Chiari I malformation. CFD was used to simulate the CSF motion and compared to the 4D PCMRI measurements. Four-dimensional PCMRI measurements had much greater CSF velocities compared to CFD simulations (1.4 to 5.6× greater). Four-dimensional PCMRI and CFD both showed anterior and anterolateral dominance of CSF velocities, although this flow feature was more pronounced in 4D PCMRI measurements compared to CFD. CSF flow jets were present near the nerve rootlets and denticulate ligaments (NRDL) in the CFD simulation. Flow jets were visible in the 4D PCMRI measurements, although they were not clearly attributable to nerve rootlets. Inclusion of spinal cord NRDL in the cervical SSS does not fully explain the differences between velocities obtained from 4D PCMRI measurements and CFD simulations.
Collapse
|
37
|
Buffi JH, Werner K, Kepple T, Murray WM. Computing muscle, ligament, and osseous contributions to the elbow varus moment during baseball pitching. Ann Biomed Eng 2015; 43:404-15. [PMID: 25281409 PMCID: PMC4340741 DOI: 10.1007/s10439-014-1144-z] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2014] [Accepted: 09/24/2014] [Indexed: 01/17/2023]
Abstract
Baseball pitching imposes a dangerous valgus load on the elbow that puts the joint at severe risk for injury. The goal of this study was to develop a musculoskeletal modeling approach to enable evaluation of muscle-tendon contributions to mitigating elbow injury risk in pitching. We implemented a forward dynamic simulation framework that used a scaled biomechanical model to reproduce a pitching motion recorded from a high school pitcher. The medial elbow muscles generated substantial, protective, varus elbow moments in our simulations. For our subject, the triceps generated large varus moments at the time of peak valgus loading; varus moments generated by the flexor digitorum superficialis were larger, but occurred later in the motion. Increasing muscle-tendon force output, either by augmenting parameters associated with strength and power or by increasing activation levels, decreased the load on the ulnar collateral ligament. Published methods have not previously quantified the biomechanics of elbow muscles during pitching. This simulation study represents a critical advancement in the study of baseball pitching and highlights the utility of simulation techniques in the study of this difficult problem.
Collapse
Affiliation(s)
- James H. Buffi
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
- SMPP, Rehabilitation Institute of Chicago, Chicago, IL, USA
| | | | | | - Wendy M. Murray
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
- SMPP, Rehabilitation Institute of Chicago, Chicago, IL, USA
- Departments of PM&R and PTHMS, Northwestern University, Chicago, IL, USA
- Edward Hines Jr. VA Hospital, Hines, IL, USA
| |
Collapse
|
38
|
He J, Zhang W, Liu Y, Li X, Li D, Jin Z. Design and fabrication of biomimetic multiphased scaffolds for ligament-to-bone fixation. Mater Sci Eng C Mater Biol Appl 2015; 50:12-8. [PMID: 25746239 DOI: 10.1016/j.msec.2015.01.088] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2014] [Revised: 01/22/2015] [Accepted: 01/30/2015] [Indexed: 11/18/2022]
Abstract
Conventional ligament grafts with single material composition cannot effectively integrate with the host bones due to mismatched properties and eventually affect their long-term function in vivo. Here we presented a multi-material strategy to design and fabricate composite scaffolds including ligament, interface and bone multiphased regions. The interface region consists of triphasic layers with varying material composition and porous structure to mimic native ligament-to-bone interface while the bone region contains polycaprolactone (PCL) anchor and microchanneled ceramic scaffolds to potentially provide combined mechanical and biological implant-bone fixation. Finite element analysis (FEA) demonstrated that the multiphased scaffolds with interference value smaller than 0.5 mm could avoid the fracture of ceramic scaffold during the implantation process, which was validated by in-vitro implanting the multiphased scaffolds into porcine joint bones. Pull-out experiment showed that the initial fixation between the multiphased scaffolds with 0.47 mm interference and the host bones could withstand the maximum force of 360.31±97.51 N, which can be improved by reinforcing the ceramic scaffolds with biopolymers. It is envisioned that the multiphased scaffold could potentially induce the regeneration of a new bone as well as interfacial tissue with the gradual degradation of the scaffold and subsequently realize long-term biological fixation of the implant with the host bone.
Collapse
Affiliation(s)
- Jiankang He
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
| | - Wenyou Zhang
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China; Qingdao R&D Institute, Xian Jiaotong University, Qingdao 266300, China
| | - Yaxiong Liu
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Xiang Li
- Department of Health Sciences and Technology, ETH Zurich, Switzerland
| | - Dichen Li
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Zhongmin Jin
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| |
Collapse
|
39
|
Abstract
The annular ligament provides a compliant connection of the stapes to the oval window. To estimate the stiffness characteristics of the annular ligament, human temporal bone measurements were conducted. A force was applied sequentially at several points on the stapes footplate leading to different patterns of displacement with different amounts of translational and rotational components. The spatial displacement of the stapes footplate was measured using a laser vibrometer. The experiments were performed on several stapes with dissected chain and the force was increased stepwise, resulting in load-deflection curves for each force application point. The annular ligament exhibited a progressive stiffening characteristic in combination with an inhomogeneous stiffness distribution. When a centric force, orientated in the lateral direction, was applied to the stapes footplate, the stapes head moved laterally and in the posterior-inferior direction. Based on the load-deflection curves, a mechanical model of the annular ligament was derived. The mathematical representation of the compliance of the annular ligament results in a stiffness matrix with a nonlinear dependence on stapes displacement. This description of the nonlinear stiffness allows simulations of the sound transfer behavior of the middle ear for different preloads.
Collapse
Affiliation(s)
- M Lauxmann
- Institute of Engineering and Computational Mechanics, University of Stuttgart, 70569 Stuttgart, Germany
| | - A Eiber
- Institute of Engineering and Computational Mechanics, University of Stuttgart, 70569 Stuttgart, Germany
| | - F Haag
- Institute of Engineering and Computational Mechanics, University of Stuttgart, 70569 Stuttgart, Germany
| | - S Ihrle
- Institute of Engineering and Computational Mechanics, University of Stuttgart, 70569 Stuttgart, Germany
| |
Collapse
|
40
|
Hammer N, Huster D, Fritsch S, Hädrich C, Koch H, Schmidt P, Sichting F, Wagner MFX, Boldt A. Do cells contribute to tendon and ligament biomechanics? PLoS One 2014; 9:e105037. [PMID: 25126746 PMCID: PMC4134275 DOI: 10.1371/journal.pone.0105037] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Accepted: 07/18/2014] [Indexed: 01/09/2023] Open
Abstract
INTRODUCTION Acellular scaffolds are increasingly used for the surgical repair of tendon injury and ligament tears. Despite this increased use, very little data exist directly comparing acellular scaffolds and their native counterparts. Such a comparison would help establish the effectiveness of the acellularization procedure of human tissues. Furthermore, such a comparison would help estimate the influence of cells in ligament and tendon stability and give insight into the effects of acellularization on collagen. MATERIAL AND METHODS Eighteen human iliotibial tract samples were obtained from nine body donors. Nine samples were acellularized with sodium dodecyl sulphate (SDS), while nine counterparts from the same donors remained in the native condition. The ends of all samples were plastinated to minimize material slippage. Their water content was adjusted to 69%, using the osmotic stress technique to exclude water content-related alterations of the mechanical properties. Uniaxial tensile testing was performed to obtain the elastic modulus, ultimate stress and maximum strain. The effectiveness of the acellularization procedure was histologically verified by means of a DNA assay. RESULTS The histology samples showed a complete removal of the cells, an extensive, yet incomplete removal of the DNA content and alterations to the extracellular collagen. Tensile properties of the tract samples such as elastic modulus and ultimate stress were unaffected by acellularization with the exception of maximum strain. DISCUSSION The data indicate that cells influence the mechanical properties of ligaments and tendons in vitro to a negligible extent. Moreover, acellularization with SDS alters material properties to a minor extent, indicating that this method provides a biomechanical match in ligament and tendon reconstruction. However, the given protocol insufficiently removes DNA. This may increase the potential for transplant rejection when acellular tract scaffolds are used in soft tissue repair. Further research will help optimize the SDS-protocol for clinical application.
Collapse
Affiliation(s)
- Niels Hammer
- Institute of Anatomy, University of Leipzig, Faculty of Medicine, Leipzig, Germany
| | - Daniel Huster
- Institute of Medical Physics and Biophysics, University of Leipzig, Faculty of Medicine, Leipzig, Germany
| | - Sebastian Fritsch
- Institute of Materials Science and Engineering, Chemnitz University of Technology, Chemnitz, Germany
| | - Carsten Hädrich
- Institute of Forensic Medicine, University of Leipzig, Faculty of Medicine, Leipzig, Germany
| | - Holger Koch
- Translational Centre for Regenerative Medicine, University of Leipzig, Faculty of Medicine, Leipzig, Germany
| | - Peter Schmidt
- Institute of Medical Physics and Biophysics, University of Leipzig, Faculty of Medicine, Leipzig, Germany
| | - Freddy Sichting
- Institute of Sport Science, Department Human Locomotion, Chemnitz University of Technology, Chemnitz, Germany
| | - Martin Franz-Xaver Wagner
- Institute of Materials Science and Engineering, Chemnitz University of Technology, Chemnitz, Germany
| | - Andreas Boldt
- Translational Centre for Regenerative Medicine, University of Leipzig, Faculty of Medicine, Leipzig, Germany
- Institute of Clinical Immunology, University of Leipzig, Faculty of Medicine, Leipzig, Germany
| |
Collapse
|
41
|
Abstract
This study was performed to evaluate a dynamic multibody model developed to characterize the influence of tibial tuberosity realignment procedures on patellofemoral motion and loading. Computational models were created to represent four knees previously tested at 40°, 60°, and 80° of flexion with the tibial tuberosity in a lateral, medial and anteromedial positions. The experimentally loaded muscles, major ligaments of the knee, and patellar tendon were represented. A repeated measures ANOVA with post-hoc testing was performed at each flexion angle to compare data between the three positions of the tibial tuberosity. Significant experimental trends for decreased patella flexion due to tuberosity anteriorization and a decrease in the lateral contact force due to tuberosity medialization were reproduced computationally. The dynamic multibody modeling technique will allow simulation of function for symptomatic knees to identify optimal surgical treatment methods based on parameters related to knee pathology and pre-operative kinematics.
Collapse
|
42
|
Trajkovski A, Omerovic S, Krasna S, Prebil I. Loading rate effect on mechanical properties of cervical spine ligaments. Acta Bioeng Biomech 2014; 16:13-20. [PMID: 25307779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Mechanical properties of cervical spine ligaments are of great importance for an accurate finite element model when analyzing the injury mechanism. However, there is still little experimental data in literature regarding fresh human cervical spine ligaments under physiological conditions. The focus of the present study is placed on three cervical spine ligaments that stabilize the spine and protect the spinal cord: the anterior longitudinal ligament, the posterior longitudinal ligament and the ligamentum flavum. The ligaments were tested within 24-48 hours after death, under two different loading rates. An increase trend in failure load, failure stress, stiffness and modulus was observed, but proved not to be significant for all ligament types. The loading rate had the highest impact on failure forces for all three ligaments (a 39.1% average increase was found). The observed increase trend, compared to the existing increase trends reported in literature, indicates the importance of carefully applying the existing experimental data, especially when creating scaling factors. A better understanding of the loading rate effect on ligaments properties would enable better case-specific human modelling.
Collapse
Affiliation(s)
- Ana Trajkovski
- The Chair of Modelling in Engineering Sciences and Medicine, Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana, Slovenia
| | - Senad Omerovic
- The Chair of Modelling in Engineering Sciences and Medicine, Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana, Slovenia
| | - Simon Krasna
- The Chair of Modelling in Engineering Sciences and Medicine, Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana, Slovenia
| | - Ivan Prebil
- The Chair of Modelling in Engineering Sciences and Medicine, Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
43
|
Nadar MS, Dashti MH, Cherian J. Finger position alters the median nerve properties within the carpal tunnel: a pre-post MRI comparison study. PLoS One 2013; 8:e79273. [PMID: 24265763 PMCID: PMC3825690 DOI: 10.1371/journal.pone.0079273] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2013] [Accepted: 09/24/2013] [Indexed: 11/23/2022] Open
Abstract
Purpose The purpose of this study was to compare the properties of the median nerve and the flexor retinaculum within the carpal tunnel with Magnetic Resonance Imaging (MRI) under two conditions: (a) fingers extended, and (b) fingers in an isometric squeeze grip. Methods Thirty-Four volunteers participated in this experimental study. The flexor retinaculum and median nerve characteristics were measured during both conditions using MRI. Results The isometric squeeze grip condition resulted in significant palmar bowing of the flexor retinaculum (t = 7.67, p<.001), a significant flattening-ratio of the median nerve (t = 4.308, p<.001), and no significant decrease in the cross-sectional area of the median nerve (t = 2.508, p = 0.017). Conclusion The isometric squeeze grip condition resulted in anatomical deformations within the carpal tunnel, possibly explained by the lumbrical muscles incursion into the carpal tunnel during finger flexion.
Collapse
Affiliation(s)
- Mohammed Shaban Nadar
- Occupational Therapy Department, Faculty of Allied Health Sciences, Kuwait University, Jabriah, Kuwait
| | - Mohsen H. Dashti
- Radiologic Sciences Department, Faculty of Allied Health Sciences, Kuwait University, Jabriah, Kuwait
| | - Jigimon Cherian
- Department of Clinical Radiology, Al-Sabah Hospital, Ministry of Health, Kuwait
- * E-mail:
| |
Collapse
|
44
|
Smith TM, Luo J, Hsu Y, Ashton-Miller J, Delancey JO. A novel technique to measure in vivo uterine suspensory ligament stiffness. Am J Obstet Gynecol 2013; 209:484.e1-7. [PMID: 23747493 DOI: 10.1016/j.ajog.2013.06.003] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2013] [Revised: 05/06/2013] [Accepted: 06/03/2013] [Indexed: 12/13/2022]
Abstract
OBJECTIVE The purpose of this study was to describe a new computer-controlled research apparatus for measuring in vivo uterine ligament force-displacement behavior and stiffness and to present pilot data for women with and without prolapse. STUDY DESIGN Seventeen women with varying uterine support underwent testing in the operating room (OR) after anesthetic induction. A tripod-mounted computer-controlled linear servoactuator was used to quantify force-displacement behavior of the cervix and supporting ligaments. The servoactuator applied a caudally directed force to a tenaculum at 4 mm/sec velocity until the traction force reached 17.8 N (4 lbs). Cervix location on Pelvic Organ Prolapse Quantification system (POP-Q) in the clinic, in the OR, at rest, and with minimal force (<1.1 N); maximum force (17.8 N) was recorded. Ligament "stiffness" between minimum and maximum force was calculated. RESULTS The mean ± SD subject age was 54.5 ± 12.7 years; parity was 2.9 ± 1.1; body mass index was 29.0 ± 4.3 kg/m(2), and POP-Q point C was -3.1 ± 3.9 cm. POP-Q point C was correlated most strongly with cervix location at maximum force (r = +0.68; P = .003) and at rest (r = +0.62; P = .009). Associations between cervix location at minimum force (r = +0.46; P = .059) and ligament stiffness (r = -0.44; P = .079) were not statistically significant. Cervix location in the OR with minimal traction lay below the lowest point found on POP-Q for 13 women. CONCLUSION POP-Q point C was correlated strongly with cervix location at rest and at maximum traction force; however, only 19% of the variation in POP-Q point C location was explained by ligament stiffness. The cervix location in the OR at minimal traction lay below POP-Q point C value in three-fourths of the women.
Collapse
Affiliation(s)
- Tovia Martirosian Smith
- Department of Obstetrics and Gynecology, University of Michigan Medical School, Ann Arbor, MI
| | | | | | | | | |
Collapse
|
45
|
Hammer N, Steinke H, Lingslebe U, Bechmann I, Josten C, Slowik V, Böhme J. Ligamentous influence in pelvic load distribution. Spine J 2013; 13:1321-30. [PMID: 23755919 DOI: 10.1016/j.spinee.2013.03.050] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2012] [Revised: 01/03/2013] [Accepted: 03/20/2013] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT The influence of the posterior pelvic ring ligaments on pelvic stability is poorly understood. Low back pain and sacroiliac joint (SIJ) pain are described being related to these ligaments. Computational approaches involving finite element (FE) modeling may aid to determine their influence. Previous FE models lacked in precise ligament geometries and material properties, which might have influence on the results. PURPOSE AND STUDY DESIGN The aim of this study is to investigate ligamentous influence in pelvic stability by means of FE using precise ligament material properties and morphometries. METHODS An FE model of the pelvis bones was created from computer tomography, including the pubic symphysis joint (PSJ) and the SIJ. Ligament data were used from 55 body donors: anterior (ASL), interosseous (ISL), and posterior (PSL) sacroiliac ligaments; iliolumbar (IL), inguinal (IN), pubic (PL), sacrospinous (SS), and sacrotuberous (ST) ligaments; and obturator membrane (OM). Stress-strain data were gained from iliotibial tract specimens. A vertical load of 600 N was applied. Pelvic motion related to altered ligament and cartilage stiffness was determined in a range of 50% to 200%. Ligament strain was investigated in the standing and sitting positions. RESULTS Tensile and compressive stresses were found at the SIJ and the PSJ. The center of sacral motion was at the level of the second sacral vertebra. At the acetabula and the PSJ, higher ligament and cartilage stiffnesses decrease pelvic motion in the following order: SIJ cartilage>ISL>ST+SS>IL+ASL+PSL. Similar effects were found for the sacrum (SIJ cartilage>ISL>IL+ASL+PSL) but increased ST+SS stiffnesses increased sacral motion. The influence of the IN, OM, and PL was less than 0.1%. Compared with standing, total ligament strain was reduced to 90%. Increased strains were found for the IL, ISL, and PSL. CONCLUSIONS Posterior pelvic ring cartilage and ligaments significantly contribute to pelvic stability. Their effects are region- and stiffness dependent. While sitting, load concentrations occur at the IL, ISL, and PSL, which goes in coherence with the clinical findings of these ligaments serving as generators of low back pain.
Collapse
Affiliation(s)
- Niels Hammer
- Faculty of Medicine, Institute of Anatomy, University of Leipzig, Liebigstraße 13, 04103 Leipzig, Germany; Department of Trauma and Reconstructive Surgery, Faculty of Medicine, University of Leipzig, Liebigstraße 13, 04103 Leipzig, Germany.
| | | | | | | | | | | | | |
Collapse
|
46
|
Luo J, Betschart C, Chen L, Ashton-Miller JA, DeLancey JOL. Using stress MRI to analyze the 3D changes in apical ligament geometry from rest to maximal Valsalva: a pilot study. Int Urogynecol J 2013; 25:197-203. [PMID: 24008367 DOI: 10.1007/s00192-013-2211-y] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2013] [Accepted: 08/10/2013] [Indexed: 11/26/2022]
Abstract
INTRODUCTION AND HYPOTHESIS A method was developed using 3D stress magnetic resonance imaging (MRI) and was piloted to test hypotheses concerning changes in apical ligament lengths and lines of action from rest to maximal Valsalva. METHODS Ten women with (cases) and ten without (controls) pelvic organ prolapse (POP) were selected from an ongoing case-control study. Supine, multiplanar stress MRI was performed at rest and at maximal Valsalva and was imported into 3D Slicer v. 3.4.1 and aligned. The 3D reconstructions of the uterus and vagina, cardinal ligament (CL), deep uterosacral ligament (USL(d)), and pelvic bones were created. Ligament length and orientation were then measured. RESULTS Adequate ligament representations were possible in all 20 study participants. When cases were compared with controls, the curve length of the CL at rest was 71 ±16 mm vs. 59 ± 9 mm (p = 0.051), and the USL(d)was 38 ± 16 mm vs. 36 ± 11 mm (p = 0.797). Similarly, the increase in CL length from rest to strain was 30 ± 16 mm vs. 15 ± 9 mm (p = 0.033), and USL(d) was 15 ± 12 mm vs. 7 ± 4 mm (p = 0.094). Likewise, the change in USL(d) angle was significantly different from CL (p < 0.001). CONCLUSIONS This technique allows quantification of 3D geometry at rest and at strain. In our pilot sample, at maximal Valsalva, CL elongation was greater in cases than controls, whereas USL(d) was not; CL also exhibited greater changes in ligament length, and USL(d) exhibited greater changes in ligament inclination angle.
Collapse
Affiliation(s)
- Jiajia Luo
- Pelvic Floor Research Group, University of Michigan, Ann Arbor, MI, USA,
| | | | | | | | | |
Collapse
|
47
|
Johnson JE, Lee P, McIff TE, Toby EB, Fischer KJ. Effectiveness of surgical reconstruction to restore radiocarpal joint mechanics after scapholunate ligament injury: an in vivo modeling study. J Biomech 2013; 46:1548-53. [PMID: 23618131 DOI: 10.1016/j.jbiomech.2013.03.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2012] [Revised: 03/12/2013] [Accepted: 03/16/2013] [Indexed: 11/19/2022]
Abstract
Disruption of the scapholunate ligament can cause a loss of normal scapholunate mechanics and eventually lead to osteoarthritis. Surgical reconstruction attempts to restore scapholunate relationship show improvement in functional outcomes, but postoperative effectiveness in restoring normal radiocarpal mechanics still remains a question. The objective of this study was to investigate the benefits of surgical repair by observing changes in contact mechanics on the cartilage surface before and after surgical treatment. Six patients with unilateral scapholunate dissociation were enrolled in the study, and displacement driven magnetic resonance image-based surface contact modeling was used to investigate normal, injured and postoperative radiocarpal mechanics. Model geometry was acquired from images of wrists taken in a relaxed position. Kinematics were acquired from image registration between the relaxed images, and images taken during functional loading. Results showed a trend for increase in radiocarpal contact parameters with injury. Peak and mean contact pressures significantly decreased after surgery in the radiolunate articulation and there were no significant differences between normal and postoperative wrists. Results indicated that surgical repair improves contact mechanics after injury and that contact mechanics can be surgically restored to be similar to normal. This study provides novel contact mechanics data on the effects of surgical repair after scapholunate ligament injury. With further work, it may be possible to more effectively differentiate between treatments and degenerative changes based on in vivo contact mechanics data.
Collapse
Affiliation(s)
- Joshua E Johnson
- Department of Mechanical Engineering, University of Kansas, 3138 Learned Hall, Lawrence, KS 66045, USA
| | | | | | | | | |
Collapse
|
48
|
Pankaj P. Patient-specific modelling of bone and bone-implant systems: the challenges. Int J Numer Method Biomed Eng 2013; 29:233-249. [PMID: 23281281 DOI: 10.1002/cnm.2536] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2012] [Revised: 11/09/2012] [Accepted: 11/12/2012] [Indexed: 06/01/2023]
Abstract
In the past three decades, finite element (FE) modelling has provided considerable understanding to the area of musculoskeletal biomechanics. However, most of this understanding has been generated using generic, standardised or idealised models. Patient-specific modelling (PSM) is almost never used for making clinical decisions. Imaging technologies have made it possible to create patient-specific geometries and FE meshes for modelling. While these have brought us closer to PSM, several challenges associated with the definition of material properties, loads, boundary conditions and interaction between components still need to be overcome. This study reviews the current status of PSM with respect to defining material behaviour and prescribing boundary conditions and interactions. With regard to the constitutive modelling of bone, it is seen that imaging is being increasingly used to define elastic properties (isotropic as well as anisotropic). However, the post-elastic and time-dependent behaviour, important for several modelling situations, is mostly obtained from in vitro experiments. Strain-based plasticity, not commonly available in FE codes, appears to have the potential of reducing an element of patient-specificity in modelling the yielding behaviour of bone. PSM of real boundary conditions that include muscles and ligaments continues to remain a challenge; many clinically relevant questions can be, however, answered without their inclusion. Simulation techniques to undertake PSM of interactions between bone and uncemented implants are available. Interference fit employed in both joint replacement fracture treatments induces considerable preload whose inclusion in models is important for the prediction of interface behaviour.
Collapse
Affiliation(s)
- Pankaj Pankaj
- School of Engineering, The University of Edinburgh, King's Buildings, Edinburgh EH9 3JL, UK.
| |
Collapse
|
49
|
Rigoldi C, Cimolin V, Camerota F, Celletti C, Albertini G, Mainardi L, Galli M. Measuring regularity of human postural sway using approximate entropy and sample entropy in patients with Ehlers-Danlos syndrome hypermobility type. Res Dev Disabil 2013; 34:840-846. [PMID: 23246558 DOI: 10.1016/j.ridd.2012.11.007] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2012] [Revised: 11/09/2012] [Accepted: 11/09/2012] [Indexed: 06/01/2023]
Abstract
Ligament laxity in Ehlers-Danlos syndrome hypermobility type (EDS-HT) patients can influence the intrinsic information about posture and movement and can have a negative effect on the appropriateness of postural reactions. Several measures have been proposed in literature to describe the planar migration of CoP over the base of support, and the most used in clinical field are the CoP excursions in antero-posterior and medio-lateral direction. In recent years a growing number of studies have been designed to explore the complexity of the COP trajectories during quiet standing. We assessed 13 adults with EDS-HT (EDSG) and 20 healthy adults (CG) during static posture, evaluating the CoP using time and frequency domain analysis and entropy analysis (SampEn and ApEn parameters). Higher values of CoP displacements in medio-lateral and anterior-posterior directions for EDSG than CG were found; no differences were observed in CoP frequency. The entropy analysis showed lower value for EDSG than CG, pointing out the needing of EDSG to concentrate more attention on postural control, loosing complexity and reflecting a less automatized postural control.
Collapse
|
50
|
Abstract
The transverse carpal ligament (TCL) serves as the origin of the thenar muscles and is integral to thenar muscle contraction anatomically and biomechanically. TCL hypertrophy has been observed in patients with carpal tunnel syndrome and is potentially caused by repetitive hand use. The purpose of this study was to investigate the biomechanical interaction between the TCL and the thenar muscles. Specifically, the morphological changes of the carpal arch, formed by the TCL, in response to thenar muscle contractions were examined during isometric tip pinch between the thumb and index finger. Ultrasound videos of the carpal tunnel were recorded from 13 healthy subjects and were synchronized with the forces measured by a pinch dynamometer. The thenar muscles' ulnar point, trapezium, and hamate were tracked by a pattern-matching program. The pinch force significantly affected the carpal arch height, width, and area (P < 0.005). As the pinch force increased from 0 to 100% maximum voluntary contraction force, the carpal arch height increased from 1.8 ± 1.0 to 2.3 ± 1.3 mm, the carpal arch width decreased from 23.9 ± 2.4 to 23.1 ± 2.4 mm, and the carpal arch area increased from 22.2 ± 13.6 to 27.3 ± 16.3 mm(2). The TCL was pulled volarly during thenar muscle contractions, providing evidence for the biomechanical interaction between the ligament and muscles. Repetitive biomechanical stimulation on the TCL from thenar muscle contractions could lead to tissue remodeling and then TCL hypertrophy. This study sheds light on the potential cause of TCL hypertrophy, which may be an etiological factor for carpal tunnel syndrome.
Collapse
Affiliation(s)
- Zhilei Liu Shen
- Department of Biomedical Engineering, Cleveland Clinic, Cleveland, Ohio 44195, USA
| | | |
Collapse
|