1
|
Schilaty ND, Walters KF, Nieuwenhuizen SVD, Bates NA, Hidalgo AV, Alikhani P. Biomechanical preservation of lumbar spine stability and motion with an intraosseous implant following vertebral body osteotomy. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2025:10.1007/s00586-025-08871-4. [PMID: 40252084 DOI: 10.1007/s00586-025-08871-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2024] [Revised: 04/10/2025] [Accepted: 04/14/2025] [Indexed: 04/21/2025]
Abstract
PURPOSE When nonsurgical treatments for low back pain with radiculopathy fail to relieve symptoms from nerve root compression, lumbar spine fusion is the standard treatment. A potential new option is using a vertebral body osteotomy (VBO) with the Vertiwedge Intraosseous System™, a novel spinal implant designed to restore foraminal height, spinal alignment, and preserve motion. The purpose was to demonstrate that VBO with the Vertiwedge implant can stabilize and correct collapsed segments while maintaining the spine's native stability and motion under various loading conditions. METHODS The Vertiwedge was biomechanically assessed in a novel spine simulator via non-destructive articulations that included randomized compression loads (0-500 N) and planar motions in flexion/extension (20°/18°), lateral flexion (19°), and axial rotation (9°). Simulations were conducted on 8 cadaveric specimens (5 M:3 F, spinal segments L1-S1, ages 35-75 years). A cubic fit model compared equivalence and linear mixed model compared stiffness with covariates of condition, motion, and compression. Change in foraminal height was not addressed as cadaveric specimens were non-pathological. RESULTS After surgical implantation, the cubic fit model demonstrated an overall equivalence (60-80%) to the Native condition. The mixed model demonstrated no differences in maximum moments between any conditions (p ≥ 0.067) or condition*motion (p ≥ 0.196). The full interaction (condition*motion*compression) demonstrated no differences of biomechanical stiffness (p ≥ 0.991). CONCLUSION The Vertiwedge, after surgical implantation, demonstrated a return of biomechanical stiffness (stability) compared to the native state of the lumbar spine specimen with all three planes of motion across various physiologic compression loads. The Vertiwedge accomplished nearly native stiffness while preserving lumbar spine motion.
Collapse
Affiliation(s)
- Nathan D Schilaty
- University of South Florida Morsani College of Medicine, Tampa, USA.
| | | | | | | | | | - Puya Alikhani
- University of South Florida Morsani College of Medicine, Tampa, USA
| |
Collapse
|
2
|
Moses J, Hach S, Mason J, Treacher A. Defining and measuring objective and subjective spinal stiffness: a scoping review. Disabil Rehabil 2023; 45:4489-4502. [PMID: 36516462 DOI: 10.1080/09638288.2022.2152878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Accepted: 11/24/2022] [Indexed: 12/15/2022]
Abstract
PURPOSE Examine and identify the breadth of definitions and measures of objective and subjective spinal stiffness in the literature, with a focus on clinical implications. METHODS A scoping review was conducted to determine what is known about definitions and measures of the specific term of spinal stiffness. Following the framework by Arksey and O'Malley, eligible peer-reviewed studies identified using PubMed, Ebsco health, and Scopus were included if they reported definitions or measures of spinal stiffness. Using a data abstraction form, the studies were classified into four themes: biomechanical, surgical, pathophysiological, and segmental spinal assessment. To identify similarities and differences between studies, sixteen categories were generated. RESULTS In total, 2426 records were identified, and 410 met the eligibility criteria. There were 350 measures (132 subjective; 218 objective measures) and 93 indicators of spinal stiffness. The majority of studies (n = 69%) did not define stiffness. CONCLUSION This review highlights the breadth of objective and subjective measures that are both clinically and methodologically diverse. There is no consensus regarding a standardised definition of stiffness in the reviewed literature.
Collapse
Affiliation(s)
- Joel Moses
- Private Practice, Cambridge, New Zealand
| | - Sylvia Hach
- School of Community Studies, Unitec Institute of Technology, Auckland, New Zealand
| | | | | |
Collapse
|
3
|
Investigation of geometric deformations of the lumbar disc during axial body rotations. BMC Musculoskelet Disord 2022; 23:225. [PMID: 35260128 PMCID: PMC8905741 DOI: 10.1186/s12891-022-05160-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 02/28/2022] [Indexed: 12/03/2022] Open
Abstract
Background Quantitative data on in vivo vertebral disc deformations are critical for enhancing our understanding of spinal pathology and improving the design of surgical materials. This study investigated in vivo lumbar intervertebral disc deformations during axial rotations under different load-bearing conditions. Methods Twelve healthy subjects (7 males and 5 females) between the ages of 25 and 39 were recruited. Using a combination of a dual fluoroscopic imaging system (DFIS) and CT, the images of L3–5 segments scanned by CT were transformed into three-dimensional models, which matched the instantaneous images of the lumbar spine taken by a double fluorescent X-ray system during axial rotations to reproduce motions. Then, the kinematic data of the compression and shear deformations of the lumbar disc and the coupled bending of the vertebral body were obtained. Results Relative to the supine position, the average compression deformation caused by rotation is between + 10% and − 40%, and the shear deformation is between 17 and 50%. Under physiological weightbearing loads, different levels of lumbar discs exhibit similar deformation patterns, and the deformation patterns of left and right rotations are approximately symmetrical. The deformation patterns change significantly under a 10 kg load, with the exception of the L3–4 disc during the right rotation. Conclusion The deformation of the lumbar disc was direction-specific and level-specific during axial rotations and was affected by extra weight. These data can provide new insights into the biomechanics of the lumbar spine and optimize the parameters of artificial lumbar spine devices.
Collapse
|
4
|
Voinier SD, Agnew MJ, Carmouche JJ. Passive stiffness characteristics and neutral zone quality of the scoliotic lumbar torso in the principle anatomical planes of motion. Clin Biomech (Bristol, Avon) 2020; 80:105162. [PMID: 32890942 DOI: 10.1016/j.clinbiomech.2020.105162] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 08/17/2020] [Accepted: 08/25/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND The 1-10% prevalence rate of adult scoliosis frequently requires expensive therapy and surgical treatments and demands further research into the disease, especially with an aging population. Most studies examining the mechanics of scoliosis have focused on in vitro testing or computer simulations. This study quantitatively defined the passive stiffness properties of the in vivo scoliotic spine in three principle anatomical motions and identified differences relative to healthy controls. METHODS Adult scoliosis (n = 14) and control (n = 17) participants with no history of spondylolisthesis, spinal fracture, or spinal surgery participated in three different tests (torso lateral side bending, torso axial rotation, and torso flexion/extension) that isolated mobility to the in vivo lumbar spine. The spinal stiffnesses and spinal neutral zone width were calculated. These parameters were statistically compared between factor of population and within factor of direction. FINDINGS Torque-rotational displacement data were fit using a double sigmoid function, resulting an in excellent overall fit (Avg. R2 = 0.95). There was a significant interaction effect between populations when comparing axial twist neutral zone width vs. lateral bend neutral zone width and axial twist stiffness vs. lateral bend stiffness. The axial twist neutral zone width magnitude was significantly larger in scoliosis patients. INTERPRETATION The present study is the first investigation to quantify the whole trunk neutral zone of the scoliotic lumbar spine. Future research is needed to determine if lumbar spine mechanical characteristics can help explain progression of scoliosis and complement scoliosis classification systems.
Collapse
Affiliation(s)
- Steven D Voinier
- Virginia Polytechnic Institute and State University, Department of Mechanical Engineering, Durham Hall, 1145 Perry St, Blacksburg, VA 24061, USA.
| | - Michael J Agnew
- Department of Industrial Systems Engineering, Virginia Polytechnic Institute and State University, Durham Hall, 1145 Perry St, Blacksburg, VA 24061, USA.
| | - Jonathan J Carmouche
- Carilion Clinic, Department of Orthopaedic Surgery, 3 Riverside Circle, Roanoke, VA 24016, USA.
| |
Collapse
|
5
|
Biomechanical properties in motion of lumbar spines with degenerative scoliosis. J Biomech 2019; 102:109495. [PMID: 31767285 DOI: 10.1016/j.jbiomech.2019.109495] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Revised: 09/26/2019] [Accepted: 11/05/2019] [Indexed: 11/21/2022]
Abstract
Degenerative lumbar scoliosis presumably alters spinal biomechanics, but a lack of quantitative reference measurements of these spines exists. We aimed to assess the biomechanical properties of spines with degenerative scoliosis, and to relate these to intervertebral disc degeneration (DD) and Cobb angle. Secondly, we compared these results to previous measurements of non-scoliotic spines. Ten cadaveric spines (Th12-L5, mean age 82 ± 11 years) with Cobb angle ≥10° and apex at L3 were acquired. Three loading cycles (-4 to 4 Nm) were applied in flexion/extension (FE), lateral bending (LB), and axial rotation (AR). The range of motion (ROM), neutral zone (NZ) stiffness, NZ ROM, elastic zone (EZ) stiffness and hysteresis were calculated for each motion segment in the loading direction. ROM was calculated in coupled directions, expressed as a percentage of rotation in the loaded direction. For Th12-L5, there was a ROM (degrees ± SD) of 14.9 ± 6.5 in FE, 14.9 ± 7.8 in LB, and 10.2 ± 5.5 in AR. The median (Nm/degree (Q1;Q3)) NZs was 0.24 (0.19;0.35) in FE, 0.25 (0.22;0.42) in LB, and 0.49 (0.33;0.99) in AR. Greater coupled motions related to higher Cobb angle, especially during AR on segments around the apex (FE: ρ = 0.539, p = 0.021 and LB: ρ = 0.821, p = 0.000). DD correlated to lower ROM and increased NZs on L2-L3 in FE (ρ = -0.721, p = 0.028 and ρ = 0.694, p = 0.038, respectively). Compared to non-scoliotic spines, smaller ROM in FE (p = 0.030) was found. This study describes the biomechanical properties of lumbar spines with degenerative scoliosis. Compared to non-scoliotic spines, they tended to be stiffer and exhibited smaller ROM in FE. DD only affected the ROM and NZs of the segments around the apex.
Collapse
|
6
|
Rustenburg CME, Faraj SSA, Holewijn RM, Kingma I, van Royen BJ, Stadhouder A, Emanuel KS. The biomechanical effect of single-level laminectomy and posterior instrumentation on spinal stability in degenerative lumbar scoliosis: a human cadaveric study. Neurosurg Focus 2019; 46:E15. [PMID: 31042658 DOI: 10.3171/2019.2.focus1911] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Accepted: 02/06/2019] [Indexed: 11/06/2022]
Abstract
OBJECTIVEDegenerative lumbar scoliosis, or de novo degenerative lumbar scoliosis, can result in spinal canal stenosis, which is often accompanied by disabling symptoms. When surgically treated, a single-level laminectomy is performed and short-segment posterior instrumentation is placed to restore stability. However, the effects of laminectomy on spinal stability and the necessity of placing posterior instrumentation are unknown. Therefore, the aim of this study was to assess the stability of lumbar spines with degenerative scoliosis, characterized by the range of motion (ROM) and neutral zone (NZ) stiffness, after laminectomy and placement of posterior instrumentation.METHODSTen lumbar cadaveric spines (T12-L5) with a Cobb angle ≥ 10° and an apex on L3 were included. Three loading cycles were applied per direction, from -4 Nm to 4 Nm in flexion/extension (FE), lateral bending (LB), and axial rotation (AR). Biomechanical evaluation was performed on the native spines and after subsequent L3 laminectomy and the placement of posterior L2-4 titanium rods and pedicle screws. Nonparametric and parametric tests were used to analyze the effects of laminectomy and posterior instrumentation on NZ stiffness and ROM, respectively, both on an individual segment's motion and on the entire spine section. Spearman's rank correlation coefficient was used to study the correlation between disc degeneration and spinal stability.RESULTSThe laminectomy increased ROM by 9.5% in FE (p = 0.04) and 4.6% in LB (p = 0.01). For NZ stiffness, the laminectomy produced no significant effects. Posterior instrumentation resulted in a decrease in ROM in all loading directions (-22.2%, -24.4%, and -17.6% for FE, LB, and AR, respectively; all p < 0.05) and an increase in NZ stiffness (+44.7%, +51.7%, and +35.2% for FE, LB, and AR, respectively; all p < 0.05). The same changes were seen in the individual segments around the apex, while the adjacent, untreated segments were mostly unaffected. Intervertebral disc degeneration was found to be positively correlated to decreased ROM and increased NZ stiffness.CONCLUSIONSLaminectomy in lumbar spines with degenerative scoliosis did not result in severe spinal instability, whereas posterior instrumentation resulted in a rigid construct. Also, prior to surgery, the spines already had lower ROM and higher NZ stiffness in comparison to values shown in earlier studies on nonscoliotic spines of the same age. Hence, the authors question the clinical need for posterior instrumentation to avoid instability.
Collapse
Affiliation(s)
| | - Sayf S A Faraj
- 2Department of Orthopedic Surgery, Radboud UMC, Nijmegen
| | | | - Idsart Kingma
- 4Amsterdam Movement Sciences, Faculty of Movement Sciences, Vrije Universiteit, Amsterdam; and
| | - Barend J van Royen
- 1Amsterdam Movement Sciences, Department of Orthopaedic Surgery, Amsterdam UMC, Amsterdam
| | - Agnita Stadhouder
- 1Amsterdam Movement Sciences, Department of Orthopaedic Surgery, Amsterdam UMC, Amsterdam
| | - Kaj S Emanuel
- 1Amsterdam Movement Sciences, Department of Orthopaedic Surgery, Amsterdam UMC, Amsterdam.,5Department of Orthopaedic Surgery, Maastricht UMC+, Maastricht, The Netherlands
| |
Collapse
|
7
|
Holewijn RM, de Kleuver M, van der Veen AJ, Emanuel KS, Bisschop A, Stadhouder A, van Royen BJ, Kingma I. A Novel Spinal Implant for Fusionless Scoliosis Correction: A Biomechanical Analysis of the Motion Preserving Properties of a Posterior Periapical Concave Distraction Device. Global Spine J 2017; 7:400-409. [PMID: 28811983 PMCID: PMC5544155 DOI: 10.1177/2192568217699377] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
STUDY DESIGN Biomechanical study. OBJECTIVE Recently, a posterior concave periapical distraction device for fusionless scoliosis correction was introduced. The goal of this study was to quantify the effect of the periapical distraction device on spinal range of motion (ROM) in comparison with traditional rigid pedicle screw-rod instrumentation. METHODS Using a spinal motion simulator, 6 human spines were loaded with 4 N m and 6 porcine spines with 2 N m to induce flexion-extension (FE), lateral bending (LB), and axial rotation (AR). ROM was measured in 3 conditions: untreated, periapical distraction device, and rigid pedicle screw-rod instrumentation. RESULTS The periapical distraction device caused a significant (P < .05) decrease in ROM of FE (human, -40.0% and porcine, -55.9%) and LB (human, -18.2% and porcine, -17.9%) as compared to the untreated spine, while ROM of AR remained unaffected. In comparison, rigid instrumentation caused a significantly (P < .05) larger decrease in ROM of FE (human, -80.9% and porcine, -94.0%), LB (human, -75.0% and porcine, -92.2%), and AR (human, -71.3% and porcine, -86.9%). CONCLUSIONS Although no destructive forces were applied, no device failures were observed. Spinal ROM was significantly less constrained by the periapical distraction device compared to rigid pedicle screw-rod instrumentation. Therefore, provided that scoliosis correction is achieved, a more physiological spinal motion is expected after scoliosis correction with the posterior concave periapical distraction device.
Collapse
Affiliation(s)
- Roderick M. Holewijn
- Department of Orthopedic Surgery, VU University Medical Center, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Marinus de Kleuver
- Department of Orthopedic Surgery, VU University Medical Center, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Albert J. van der Veen
- Department of Physics and Medical Technology, VU University Medical Center, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Kaj S. Emanuel
- Department of Orthopedic Surgery, VU University Medical Center, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Arno Bisschop
- Department of Orthopedic Surgery, VU University Medical Center, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Agnita Stadhouder
- Department of Orthopedic Surgery, VU University Medical Center, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Barend J. van Royen
- Department of Orthopedic Surgery, VU University Medical Center, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Idsart Kingma
- Department of Human Movement Sciences, Vrije Universiteit, Amsterdam Movement Sciences, Amsterdam, The Netherlands,Idsart Kingma, Department of Human Movement Sciences, Vrije Universiteit, Amsterdam Movement Sciences, Van der Boechorststraat 7, 1081 BT Amsterdam, The Netherlands.
| |
Collapse
|
8
|
Balkovec C, Vernengo AJ, McGill SM. Disc height loss and restoration via injectable hydrogel influences adjacent segment mechanics in-vitro. Clin Biomech (Bristol, Avon) 2016; 36:1-7. [PMID: 27186646 DOI: 10.1016/j.clinbiomech.2016.05.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 04/25/2016] [Accepted: 05/03/2016] [Indexed: 02/07/2023]
Abstract
BACKGROUND Height loss can have a profound influence on the local mechanical environment of the disc. While disc height loss is incorporated into scales of degeneration, its direct influence on spine kinematics is unclear. Further, there is a need for minimally invasive techniques to restore disc height; injectable hydrogels are a potential solution. Tandem investigation of disc height loss and subsequent restoration will enhance understanding of spine dysfunction and aberrant movement. METHODS Twenty porcine spine specimens with two functional segments were tested in repeated flexion and extension. Relative angular displacement of each segment was measured with full specimen disc height, disc height loss in one of the segments (superior or inferior), and disc height restoration via hydrogel injection. FINDINGS Disc height loss decreased the range of motion at the affected segment and increased the range of motion at the adjacent segment. Relative angular displacement decreased at the affected segment by 13.8% (SD=5.3%) and 4.5% (SD=2.1%) for specimens with height loss in the superior and inferior discs respectively. Hydrogel injection was able to restore segmental kinematics to the pre-injury state, with 12.7% (SD=5.5%) and 6.4% (SD=4.2%) of motion regained at the affected segment for superior and inferior disc height loss specimens respectively. INTERPRETATION Acute disc height loss reduces motion at an affected segment, while increasing motion at an adjacent segment in-vitro; relative motion appears to be governed by local stiffness. Injectable hydrogels show promise in their ability to restore kinematics to segments with disc height loss.
Collapse
|
9
|
Holewijn RM, Schlösser TPC, Bisschop A, van der Veen AJ, Stadhouder A, van Royen BJ, Castelein RM, de Kleuver M. How Does Spinal Release and Ponte Osteotomy Improve Spinal Flexibility? The Law of Diminishing Returns. Spine Deform 2015; 3:489-495. [PMID: 27927536 DOI: 10.1016/j.jspd.2015.03.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2014] [Revised: 02/12/2015] [Accepted: 03/10/2015] [Indexed: 10/23/2022]
Abstract
STUDY DESIGN Experimental study. OBJECTIVES To evaluate the effect of stepwise resection of posterior spinal ligaments, facet joints, and ribs on thoracic spinal flexibility. SUMMARY OF BACKGROUND DATA Posterior spinal ligaments, facet joints and ribs are removed to increase spinal flexibility in corrective spinal surgery for deformities such as adolescent idiopathic scoliosis (AIS). Reported clinical results vary and biomechanical substantiation is lacking. METHODS Ten fresh-frozen human cadaveric thoracic spinal specimens (T6-T11) were studied. A spinal motion simulator applied a pure moment of ±2.5 Nm in flexion, extension, lateral bending (LB) and axial rotation (AR). Range of motion (ROM) was measured for the intact spine and measured again after stepwise resection of the supra/interspinous ligament (SIL), inferior facet, flaval ligament, superior facet, and rib heads. RESULTS SIL resection increased ROM in flexion (10.2%) and AR (3.1%). Successive inferior facetectomy increased ROM in flexion (4.1%), LB (3.8%) and AR (7.7%), and flavectomy in flexion (9.1%) and AR (2.5%). Sequential superior facetectomy only increased ROM in flexion (6.3%). Rib removal provided an additional increase in flexion (6.3%), LB (4.5%) and AR (13.0%). Extension ROM increased by 10.5% after the combined removal of the SIL, inferior facet and flaval ligament. CONCLUSIONS Posterior spinal releases in these non-scoliotic spines led to an incremental increase in spinal flexibility, but each sequential step had less effect. As compared to SIL resection with inferior facetectomy, additional superior facetectomy did not improve flexibility in AR and LB and only 6.3% in flexion. The data presented from this in vitro study should be interpreted with care, as no representative cadaveric spine model for AIS was available, However, the results presented here at least question the benefits of performing routine complete facetectomies (i.e. Ponte osteotomies) to increase spinal flexibility in scoliosis surgery.
Collapse
Affiliation(s)
- Roderick M Holewijn
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Tom P C Schlösser
- Department of Orthopaedic Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, The Netherlands
| | - Arno Bisschop
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Albert J van der Veen
- Department of Physics and Medical Technology, VU University Medical Center, De Boelelaan 1118, 1081 HV Amsterdam, The Netherlands
| | - Agnita Stadhouder
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Barend J van Royen
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - René M Castelein
- Department of Orthopaedic Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, The Netherlands
| | - Marinus de Kleuver
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
| |
Collapse
|
10
|
Trunk-pelvis motion, joint loads, and muscle forces during walking with a transtibial amputation. Gait Posture 2015; 41:757-62. [PMID: 25748611 DOI: 10.1016/j.gaitpost.2015.01.016] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2014] [Revised: 12/20/2014] [Accepted: 01/15/2015] [Indexed: 02/02/2023]
Abstract
People with unilateral, transtibial amputation (TTA) have an increased prevalence of chronic low back pain (LBP) relative to able-bodied people. However, a definitive cause of increased LBP susceptibility has not been determined. The purpose of this work was to compare dynamic trunk-pelvis biomechanics between people with (n=6) and without (n=6) unilateral TTA during walking using a computational modeling approach. A generic, muscle-actuated whole body model was scaled to each participant, and experimental walking data were used in a static optimization framework to calculate trunk-pelvis motion, L4L5 joint contact forces, and muscle forces within the trunk-pelvis region. Results included several significant between-group differences in trunk-pelvis biomechanics during different phases of the gait cycle. Most significant was greater lateral bending toward the residual side during residual single-limb stance (p<0.01), concurrent with an elevated L4L5 joint contact force (p=0.02) and greater muscle force from the intact-side obliques (p<0.01) in people with TTA relative to able-bodied people. During both double-limb support phases, people with TTA also had a greater range of axial trunk rotation away from the leading limb, concurrent with greater ranges of muscle forces in the erector spinae and obliques. In addition, a greater range of force (p=0.03) in residual-side psoas was found during early residual limb swing in people with TTA. Repeated exposure to atypical motion and joint/muscle loading in people with TTA may contribute to the development of secondary musculoskeletal disorders, including chronic, mechanical LBP.
Collapse
|
11
|
Bisschop A, Holewijn RM, Kingma I, Stadhouder A, Vergroesen PPA, van der Veen AJ, van Dieën JH, van Royen BJ. The effects of single-level instrumented lumbar laminectomy on adjacent spinal biomechanics. Global Spine J 2015; 5:39-48. [PMID: 25649753 PMCID: PMC4303474 DOI: 10.1055/s-0034-1395783] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2014] [Accepted: 10/11/2014] [Indexed: 11/15/2022] Open
Abstract
Study Design Biomechanical study. Objective Posterior instrumentation is used to stabilize the spine after a lumbar laminectomy. However, the effects on the adjacent segmental stability are unknown. Therefore, we studied the range of motion (ROM) and stiffness of treated lumbar spinal segments and cranial segments after a laminectomy and after posterior instrumentation in flexion and extension (FE), lateral bending (LB), and axial rotation (AR). These outcomes might help to better understand adjacent segment disease (ASD), which is reported cranial to the level on which posterior instrumentation is applied. Methods We obtained 12 cadaveric human lumbar spines. Spines were axially loaded with 250 N for 1 hour. Thereafter, 10 consecutive load cycles (4 Nm) were applied in FE, LB, and AR. Subsequently, a laminectomy was performed either at L2 or at L4. Thereafter, load-deformation tests were repeated, after similar preloading. Finally, posterior instrumentation was added to the level treated with a laminectomy before testing was repeated. The ROM and stiffness of the treated, the cranial adjacent, and the control segments were calculated from the load-displacement data. Repeated-measures analyses of variance used the spinal level as the between-subject factor and a laminectomy or instrumentation as the within-subject factors. Results After the laminectomy, the ROM increased (+19.4%) and the stiffness decreased (-18.0%) in AR. The ROM in AR of the adjacent segments also increased (+11.0%). The ROM of treated segments after instrumentation decreased in FE (-74.3%), LB (-71.6%), and AR (-59.8%). In the adjacent segments after instrumentation, only the ROM in LB was changed (-12.9%). Conclusions The present findings do not substantiate a biomechanical pathway toward or explanation for ASD.
Collapse
Affiliation(s)
- Arno Bisschop
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, Amsterdam, The Netherlands,Address for correspondence Arno Bisschop, MD (Hons) Department of Orthopaedic Surgery, Research Institute MOVEVU University Medical Center, De Boelelaan 1117, 1081 HV AmsterdamThe Netherlands
| | - Roderick M. Holewijn
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, Amsterdam, The Netherlands
| | - Idsart Kingma
- Faculty of Human Movement Sciences, Research Institute MOVE, VU University Amsterdam, Amsterdam, The Netherlands
| | - Agnita Stadhouder
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, Amsterdam, The Netherlands
| | - Pieter-Paul A. Vergroesen
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, Amsterdam, The Netherlands
| | - Albert J. van der Veen
- Department of Physics and Medical Technology, VU University Medical Center, Amsterdam, The Netherlands
| | - Jaap H. van Dieën
- Faculty of Human Movement Sciences, Research Institute MOVE, VU University Amsterdam, Amsterdam, The Netherlands,Department of Biomedical Engineering, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Barend J. van Royen
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, Amsterdam, The Netherlands
| |
Collapse
|
12
|
Maquer G, Laurent M, Brandejsky V, Pretterklieber ML, Zysset PK. Finite element based nonlinear normalization of human lumbar intervertebral disc stiffness to account for its morphology. J Biomech Eng 2014; 136:061003. [PMID: 24671515 DOI: 10.1115/1.4027300] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2013] [Indexed: 11/08/2022]
Abstract
Disc degeneration, usually associated with low back pain and changes of intervertebral stiffness, represents a major health issue. As the intervertebral disc (IVD) morphology influences its stiffness, the link between mechanical properties and degenerative grade is partially lost without an efficient normalization of the stiffness with respect to the morphology. Moreover, although the behavior of soft tissues is highly nonlinear, only linear normalization protocols have been defined so far for the disc stiffness. Thus, the aim of this work is to propose a nonlinear normalization based on finite elements (FE) simulations and evaluate its impact on the stiffness of human anatomical specimens of lumbar IVD. First, a parameter study involving simulations of biomechanical tests (compression, flexion/extension, bilateral torsion and bending) on 20 FE models of IVDs with various dimensions was carried out to evaluate the effect of the disc's geometry on its compliance and establish stiffness/morphology relations necessary to the nonlinear normalization. The computed stiffness was then normalized by height (H), cross-sectional area (CSA), polar moment of inertia (J) or moments of inertia (Ixx, Iyy) to quantify the effect of both linear and nonlinear normalizations. In the second part of the study, T1-weighted MRI images were acquired to determine H, CSA, J, Ixx and Iyy of 14 human lumbar IVDs. Based on the measured morphology and pre-established relation with stiffness, linear and nonlinear normalization routines were then applied to the compliance of the specimens for each quasi-static biomechanical test. The variability of the stiffness prior to and after normalization was assessed via coefficient of variation (CV). The FE study confirmed that larger and thinner IVDs were stiffer while the normalization strongly attenuated the effect of the disc geometry on its stiffness. Yet, notwithstanding the results of the FE study, the experimental stiffness showed consistently higher CV after normalization. Assuming that geometry and material properties affect the mechanical response, they can also compensate for one another. Therefore, the larger CV after normalization can be interpreted as a strong variability of the material properties, previously hidden by the geometry's own influence. In conclusion, a new normalization protocol for the intervertebral disc stiffness in compression, flexion, extension, bilateral torsion and bending was proposed, with the possible use of MRI and FE to acquire the discs' anatomy and determine the nonlinear relations between stiffness and morphology. Such protocol may be useful to relate the disc's mechanical properties to its degree of degeneration.
Collapse
|
13
|
Bisschop A, van Engelen SJPM, Kingma I, Holewijn RM, Stadhouder A, van der Veen AJ, van Dieën JH, van Royen BJ. Single level lumbar laminectomy alters segmental biomechanical behavior without affecting adjacent segments. Clin Biomech (Bristol, Avon) 2014; 29:912-7. [PMID: 25028214 DOI: 10.1016/j.clinbiomech.2014.06.016] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2013] [Revised: 05/08/2014] [Accepted: 06/16/2014] [Indexed: 02/07/2023]
Abstract
BACKGROUND Degenerative lumbar spinal stenosis causes neurological symptoms due to neural compression. Lumbar laminectomy is a commonly used treatment for symptomatic degenerative spinal stenosis. However, it is unknown if and to what extent single level laminectomy affects the range of motion and stiffness of treated and adjacent segments. An increase in range of motion and a decrease in stiffness are possible predictors of post-operative spondylolisthesis or spinal failure. METHODS Twelve cadaveric human lumbar spines were obtained. After preloading, spines were tested in flexion-extension, lateral bending, and axial rotation. Subsequently, single level lumbar laminectomy analogous to clinical practice was performed at level lumbar 2 or 4. Thereafter, load-deformation tests were repeated. The range of motion and stiffness of treated and adjacent segments were calculated before and after laminectomy. Untreated segments were used as control group. Effects of laminectomy on stiffness and range of motion were tested, separately for treated, adjacent and control segments, using repeated measures analysis of variance. FINDINGS Range of motion at the level of laminectomy increased significantly for flexion and extension (7.3%), lateral bending (7.5%), and axial rotation (12.2%). Range of motion of adjacent segments was only significantly affected in lateral bending (-7.7%). Stiffness was not affected by laminectomy. INTERPRETATION The increase in range of motion of 7-12% does not seem to indicate the use of additional instrumentation to stabilize the lumbar spine. If instrumentation is still considered in a patient, its primary focus should be on re-stabilizing only the treated segment level.
Collapse
Affiliation(s)
- Arno Bisschop
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
| | - Susanne J P M van Engelen
- Research Institute MOVE, Faculty of Human Movement Sciences, VU University, Amsterdam, The Netherlands
| | - Idsart Kingma
- Research Institute MOVE, Faculty of Human Movement Sciences, VU University, Amsterdam, The Netherlands
| | - Roderick M Holewijn
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Agnita Stadhouder
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Albert J van der Veen
- Department of Physics and Medical Technology, VU University Medical Center, The Netherlands
| | - Jaap H van Dieën
- Research Institute MOVE, Faculty of Human Movement Sciences, VU University, Amsterdam, The Netherlands; Department of Biomedical Engineering, King Abdulaziz University, Saudi Arabia
| | - Barend J van Royen
- Department of Orthopaedic Surgery, Research Institute MOVE, VU University Medical Center, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
| |
Collapse
|