de Oliveira LAS, Dibai-Filho AV, de Santana GN, da Silva ACB, da Silva Júnior JEF, Dos Santos PG, de Paula Gomes CAF. Translation, cross-cultural adaptation, and analysis of the measurement properties of the Fremantle Knee Awareness Questionnaire (FreKAQ) into Brazilian Portuguese for individuals with knee osteoarthritis.
BMC Musculoskelet Disord 2025;
26:357. [PMID:
40221739 PMCID:
PMC11992693 DOI:
10.1186/s12891-024-08152-z]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Accepted: 12/04/2024] [Indexed: 04/14/2025] Open
Abstract
OBJECTIVE
This study aimed to translate and cross-culturally adapt the Fremantle Knee Awareness Questionnaire (FreKAQ) into Brazilian Portuguese and evaluate the measurement properties, including internal consistency, construct validity, reliability, and ceiling and floor effects in individuals with knee osteoarthritis (KOA).
METHODS
Translation, cross-cultural adaptation, and analysis of measurement properties were performed according to international recommendations. One hundred thirty-four individuals diagnosed with KOA participated in the study. Of these, 30 participated in the validation process of the pre-final version of the FreKAQ. One hundred four were evaluated with the FreKAQ, the Numeric Pain Rating Scale (NPRS), the Pain Catastrophizing Scale (PCS), the International Knee Documentation Committee (IKDC), and the 36-item short-form survey (SF-36). The construct validity was tested using Spearman's correlation coefficient, and ceiling and floor effects were calculated. A subsample of 54 participants participated in the reproducibility assessment. Internal consistency was calculated using Cronbach's alpha. Reproducibility was assessed using the test-retest model using the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimum detectable change (MDC).
RESULTS
the FreKAQ showed a favorable correlation with the construct's intensity and catastrophizing related to pain and activities of daily living (p < 0.01). It also had the functional capacity, pain, social aspects, and emotional aspects of the SF-36 (p < 0.05). Additionally, it presented excellent ICC (0.91) and adequate internal consistency (0.91) with the SEM and MDC scores, respectively, 2.86 and 7.94. There were no ceiling or floor effects.
CONCLUSION
The FreKAQ showed adequate measurement properties in individuals with KOA, indicating its use as an evaluative measure of body perception of the knee.
Collapse