1
|
Mochizuki R, Ogra Y. Determination of intracellular dopamine by liquid chromatography-fluorescence detection with post-column derivatization using the König reaction. J Chromatogr B Analyt Technol Biomed Life Sci 2024; 1232:123956. [PMID: 38128164 DOI: 10.1016/j.jchromb.2023.123956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 11/28/2023] [Accepted: 12/05/2023] [Indexed: 12/23/2023]
Abstract
Dopamine is an important neurotransmitter, and the disruption of dopaminergic homeostasis causes various neurological diseases such as Parkinson's disease. Analysis of intracellular dopamine levels is important to understand the pathology of neurological diseases. We have developed a new method for the fluorometric detection of dopamine by adopting the König reaction, which is commonly used for the detection of cyanide, thiocyanate, and selenocyanate, and demonstrated that it can be applied to the determination of intracellular dopamine levels. The present method only requires a conventional LC system with isocratic elution and post-column derivatization and is simple to perform. The LOD, LOQ, and linearity range were 10.8 nM, 32.8 nM, and 0.05-10 μM, respectively, with accuracies of 101.8-106.3 % and precisions within 5 %, which are sufficient for the quantification of intracellular dopamine. We also determined dopamine levels in PC12 cells and found that the levels increased and decreased when the cells were exposed to L-dopa and cyanide, respectively, possibly because of the conversion of L-dopa into dopamine and the depletion of intracellular dopamine by exposing cells to cyanide, respectively. These results suggest the applicability of the present method, and that this new use of the König reaction offers a reliable and useful means of quantifying intracellular dopamine.
Collapse
Affiliation(s)
- Ryu Mochizuki
- Graduate School of Pharmaceutical Sciences, Chiba University, 1-8-1 Inohana, Chuo, Chiba, Chiba 260-8675, Japan
| | - Yasumitsu Ogra
- Graduate School of Pharmaceutical Sciences, Chiba University, 1-8-1 Inohana, Chuo, Chiba, Chiba 260-8675, Japan.
| |
Collapse
|
2
|
Tang K, Mahata SK. Determination of Catecholamines in a Small Volume (25 μL) of Plasma from Conscious Mouse Tail Vein. Methods Mol Biol 2023; 2565:331-342. [PMID: 36205904 PMCID: PMC10798352 DOI: 10.1007/978-1-0716-2671-9_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
The determination of plasma catecholamine levels is commonly used as a measure of the sympathetic nervous system's response to stress and is highly important for diagnosis, therapy, and prognosis of cardiovascular diseases, catecholamine-secreting tumors arising from the chromaffin cells of the sympathoadrenal system, and affective disorders. Diseases in which catecholamines are significantly elevated include pheochromocytoma, Parkinson's disease, Alzheimer's disease, neuroblastoma, ganglioneuroblastoma, von Hippel-Lindau disease, baroreflex failure, chemodectina (nonchromaffin paraganglioma), and multiple endocrine neoplasia. Plasma norepinephrine levels provide a guide to prognosis in patients with stable, chronic, and congestive heart diseases. The method described here for the determination of plasma catecholamines is based on the principle that plasma catecholamines are selectively adsorbed on acid-washed alumina at pH 8.7 and then eluted at a pH between 1.0 and 2.0. Upon injection, catecholamines in elutes were separated by a reversed phase C-18 column. After separation, the catecholamines present within the mobile phase enter the electrochemical detector. Electrochemical detection occurs because electroactive compounds oxidize at a certain potential and thereby liberate electrons that create measurable current. Catecholamines readily form quinones under these conditions, get oxidized, release two electrons, and create current. The electrochemical detector detects this electrical current that linearly correlates to the catecholamine concentration loaded into the ultra-performance liquid chromatography instrument. A 15-min mixing time during the adsorption and desorption steps was found to be optimal. If the washing step was omitted, the catecholamines could not be eluted from the acid-washed alumina. To prevent dilution, the alumina had to be centrifuged and not aspirated to dryness after the washing step. We report here that by changing the range in the electrochemical detector, plasma catecholamines were measured with only 12.5 μL of plasma and more reliably with 25 μL of plasma. The detection limit was 1 ng/mL. This assay method is very useful as blood can be collected from the tail vein in a conscious mouse and the same mouse can be used for time-dependent or age-dependent studies.
Collapse
Affiliation(s)
- Kechun Tang
- VA San Diego Healthcare System, San Diego, CA, USA
| | - Sushil K Mahata
- VA San Diego Healthcare System, San Diego, CA, USA.
- Department of Medicine, University of California San Diego, La Jolla, CA, USA.
| |
Collapse
|
3
|
Rodriguez-Salazar L, Guevara-Pulido J, Cifuentes A. In Silico Design of a Peptide Receptor for Dopamine Recognition. Molecules 2020; 25:E5509. [PMID: 33255517 PMCID: PMC7727804 DOI: 10.3390/molecules25235509] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 10/03/2020] [Accepted: 10/08/2020] [Indexed: 12/24/2022] Open
Abstract
Dopamine (DA) is an important neurotransmitter with a fundamental role in regulatory functions related to the central, peripheral, renal, and hormonal nervous systems. Dopaminergic neurotransmission dysfunctions are commonly associated with several diseases; thus, in situ quantification of DA is a major challenge. To achieve this goal, enzyme-based biosensors have been employed for substrate recognition in the past. However, due to their sensitivity to changes in temperature and pH levels, new peptide bioreceptors have been developed. Therefore, in this study, four bioreceptors were designed in silico to exhibit a higher affinity for DA than the DA transporters (DATs). The design was based on the hot spots of the active sites of crystallized enzyme structures that are physiologically related to DA. The affinities between the chosen targets and designed bioreceptors were calculated using AutoDock Vina. Additionally, the binding free energy, ∆G, of the dopamine-4xp1 complex was calculated by molecular dynamics (MD). This value presented a direct relationship with the E_refine value obtained from molecular docking based on the ∆G functions obtained from MOE of the promising bioreceptors. The control variables in the design were amino acids, bond type, steric volume, stereochemistry, affinity, and interaction distances. As part of the results, three out of the four bioreceptor candidates presented promising values in terms of DA affinity and distance.
Collapse
Affiliation(s)
| | - James Guevara-Pulido
- Química Farmacéutica, Facultad de Ciencias, Universidad El Bosque, Bogotá 110121, Colombia;
| | - Andrés Cifuentes
- Química Farmacéutica, Facultad de Ciencias, Universidad El Bosque, Bogotá 110121, Colombia;
| |
Collapse
|
4
|
Noori R, Perwez M, Mazumder JA, Sardar M. Development of low-cost paper-based biosensor of polyphenol oxidase for detection of phenolic contaminants in water and clinical samples. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:30081-30092. [PMID: 32447731 DOI: 10.1007/s11356-020-09331-w] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 05/14/2020] [Indexed: 06/11/2023]
Abstract
In the present work, polyphenol oxidase (PPO) enzyme was purified from potato peel using three-phase partitioning (TPP). In this method, ammonium sulfate and t-butanol were added to precipitate the protein/enzyme from the crude aqueous extract. The PPO enzyme precipitated as an interfacial layer between the upper organic solvent phase and lower aqueous phase. Different purification parameters such as crude extract to t-butanol ratio, ammonium sulfate concentration, temperature, and pH were optimized for TPP. About 69% PPO enzyme activity was recovered in a single step of TPP with 9.2-fold purification. The sodium dodecyl sulfate-polyacrylamide gel electrophoresis profile of partially purified PPO enzyme showed molecular weight in the range of about 30-40 kDa. The PPO enzyme was then investigated for the fabrication of a portable, cost-effective, and disposable colorimetric paper biosensor or colorimetric "test strips" for detection of phenolic contaminants. PPO and a chromophore reagent (3-methyl-2-benzothiazolinone hydrazine) generated a range of color in the presence of phenolic compounds (catechol, phenol, p-cresol, 4-methyl catechol) within 15 min, and limit of detection was found to be 0.5 μM. The biosensor worked in a broad range of pH from 3 to 11 and showed good storage stability at 25 °C and 4 °C for 30 days with no significant loss of activity. The biosensor was also applied on environmental water and urine sample to show reliability of biosensor.
Collapse
Affiliation(s)
- Rubia Noori
- Department of Biosciences, Jamia Millia Islamia, New Delhi, 110025, India
| | - Mohammad Perwez
- Department of Biosciences, Jamia Millia Islamia, New Delhi, 110025, India
| | | | - Meryam Sardar
- Department of Biosciences, Jamia Millia Islamia, New Delhi, 110025, India.
| |
Collapse
|
5
|
Abrantes Dias AS, Amaral Pinto JC, Magalhães M, Mendes VM, Manadas B. Analytical methods to monitor dopamine metabolism in plasma: Moving forward with improved diagnosis and treatment of neurological disorders. J Pharm Biomed Anal 2020; 187:113323. [DOI: 10.1016/j.jpba.2020.113323] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 04/16/2020] [Accepted: 04/17/2020] [Indexed: 12/16/2022]
|
6
|
Chen L, Tang Y, Xu B, Xu Z, Shen J, Zhang W. Automated on-line packed fiber solid phase extraction for determination of urinary catecholamines. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1139:121983. [DOI: 10.1016/j.jchromb.2020.121983] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Revised: 01/01/2020] [Accepted: 01/11/2020] [Indexed: 12/16/2022]
|
7
|
LC-MS determination of catecholamines and related metabolites in red deer urine and hair extracted using magnetic multi-walled carbon nanotube poly(styrene-co-divinylbenzene) composite. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1136:121878. [PMID: 31812837 DOI: 10.1016/j.jchromb.2019.121878] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 10/23/2019] [Accepted: 11/08/2019] [Indexed: 12/30/2022]
Abstract
A novel analytical methodology for the extraction and determination of catecholamines (dopamine, epinephrine and norepinephrine) and their metabolites DL-3,4-dihydroxyphenyl glycol and DL-3,4-dihydroxymandelic acid by LC-MS is developed and validated for its application to human and animal urine and hair samples. The method is based on the preliminary extraction of the analytes by a magnetic multi-walled carbon nanotube poly(styrene-co-divinylbenzene) composite. This is followed by a <9 min chromatographic separation of the target compounds in an Onyx Monolithic C18 column using a mixture of 0.01% (v/v) heptafluorobutyric acid in water and methanol at 500 µL min-1 flow rate. Detection limits within range from 0.055 to 0.093 µg mL-1, and precision values of the response and retention times of analytes were >90%. Accuracy values comprised the range 79.5-109.5% when the analytes were extracted from deer urine samples using the selected MMWCNT-poly(STY-DVB) sorbent. This methodology was applied to real red deer urine and hair samples, and concentrations within range from 0.05 to 0.5 µg mL-1 for norepinephrine and from 1.0 to 44.5 µg mL-1 for its metabolite 3,4-dihydroxyphenyl glycol were calculated. Analyses of red deer hair resulted in high amounts of 3,4-dihydroxyphenyl glycol (0.9-266.9 µg mL-1).
Collapse
|
8
|
Castillo-Aguirre A, Maldonado M. Preparation of Methacrylate-based Polymers Modified with Chiral Resorcinarenes and Their Evaluation as Sorbents in Norepinephrine Microextraction. Polymers (Basel) 2019; 11:E1428. [PMID: 31480387 PMCID: PMC6780700 DOI: 10.3390/polym11091428] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Revised: 08/19/2019] [Accepted: 08/26/2019] [Indexed: 11/17/2022] Open
Abstract
Aminomethylation reactions between chiral amino compounds (S)-(-)-1-phenylethylamine and l-proline with tetranonylresorcinarene and tetra-(4-hydroxyphenyl)resorcinarene in presence of formaldehyde were studied. The reaction between l-proline and resorcinarenes generated regioselectively chiral tetra-Mannich bases, due to the molecular incorporation of the fragment of the chiral amino acid. On the other hand, tetranonylresorcinarene and (S)-(-)-1-phenylethylamine formed regio- and diasteroselectively chiral tetrabenzoxazines, both by chiral auxiliary functionalization and by the transformation of the molecular structure that confers inherent chirality. The products obtained were characterized using IR, 1H-NMR, 13C-NMR, COSY, HMQC, and HMBC techniques. The reaction of (S)-(-)-1-phenylethylamine with tetra-(4-hydroxyphenyl)resorcinarene did not proceed under the experimental conditions. Once the chiral aminomethylated tetra-(4-hydroxyphenyl)resorcinarene was obtained, the chemical modification of poly(GMA-co-EDMA) was studied, and the results showed an efficient incorporation of the aminomethylated compound. For the physical modification, chiral aminomethylated tetranonylresorcinarenes were employed, finding that the incorporation of modified resorcinarenes occurs, but with less efficiency than that observed using chemical modification. The modified polymers were characterized via FT-IR, scanning electron microscopy imaging, and elemental analysis. Finally, polymers modified with chiral resorcinarenes were used as sorbents in norepinephrine microextraction; for practical purposes, artificial urine was prepared and used. To perform the microextraction, the decision was made to use the modern rotating-disk sorptive extraction technique (RDSE), because of its analytical attributes as a green, or eco-friendly, technique. According to the results, the method preliminarily validated for the determination of norepinephrine in artificial urine shows that the modified polymer with chiral derivative of tetra-(4-hydroxyphenyl)resorcinarene worked effectively as a new sorbent phase for the quantitative microextraction of norepinephrine, exhibiting high stability and homogeneity of composition and structure within the working range.
Collapse
Affiliation(s)
- Alver Castillo-Aguirre
- Departamento de Química, Facultad de Ciencias, Universidad Nacional de Colombia-Sede Bogotá, 30 No. 45, Carrera 03, Colombia
| | - Mauricio Maldonado
- Departamento de Química, Facultad de Ciencias, Universidad Nacional de Colombia-Sede Bogotá, 30 No. 45, Carrera 03, Colombia.
| |
Collapse
|
9
|
Jung-Klawitter S, Kuseyri Hübschmann O. Analysis of Catecholamines and Pterins in Inborn Errors of Monoamine Neurotransmitter Metabolism-From Past to Future. Cells 2019; 8:cells8080867. [PMID: 31405045 PMCID: PMC6721669 DOI: 10.3390/cells8080867] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Revised: 08/02/2019] [Accepted: 08/04/2019] [Indexed: 12/13/2022] Open
Abstract
Inborn errors of monoamine neurotransmitter biosynthesis and degradation belong to the rare inborn errors of metabolism. They are caused by monogenic variants in the genes encoding the proteins involved in (1) neurotransmitter biosynthesis (like tyrosine hydroxylase (TH) and aromatic amino acid decarboxylase (AADC)), (2) in tetrahydrobiopterin (BH4) cofactor biosynthesis (GTP cyclohydrolase 1 (GTPCH), 6-pyruvoyl-tetrahydropterin synthase (PTPS), sepiapterin reductase (SPR)) and recycling (pterin-4a-carbinolamine dehydratase (PCD), dihydropteridine reductase (DHPR)), or (3) in co-chaperones (DNAJC12). Clinically, they present early during childhood with a lack of monoamine neurotransmitters, especially dopamine and its products norepinephrine and epinephrine. Classical symptoms include autonomous dysregulations, hypotonia, movement disorders, and developmental delay. Therapy is predominantly based on supplementation of missing cofactors or neurotransmitter precursors. However, diagnosis is difficult and is predominantly based on quantitative detection of neurotransmitters, cofactors, and precursors in cerebrospinal fluid (CSF), urine, and blood. This review aims at summarizing the diverse analytical tools routinely used for diagnosis to determine quantitatively the amounts of neurotransmitters and cofactors in the different types of samples used to identify patients suffering from these rare diseases.
Collapse
Affiliation(s)
- Sabine Jung-Klawitter
- Department of General Pediatrics, Division of Neuropediatrics and Metabolic Medicine, University Hospital Heidelberg, 69120 Heidelberg, Germany.
| | - Oya Kuseyri Hübschmann
- Department of General Pediatrics, Division of Neuropediatrics and Metabolic Medicine, University Hospital Heidelberg, 69120 Heidelberg, Germany
| |
Collapse
|
10
|
He X, Yu Y, Li Y. Facile synthesis of boronic acid-functionalized magnetic metal-organic frameworks for selective extraction and quantification of catecholamines in rat plasma. RSC Adv 2018; 8:41976-41985. [PMID: 35558777 PMCID: PMC9092088 DOI: 10.1039/c8ra07356b] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2018] [Accepted: 11/21/2018] [Indexed: 11/30/2022] Open
Abstract
Precise determination of the endogenous catecholamines, dopamine (DA), epinephrine (E) and norepinephrine (NE) faces substantial challenges due to their low physiological concentrations in plasma. We synthesized, for the first time, a magnetic metal-organic framework (MIL-100) composite with boronic acid-functionalized pore-walls (denoted as MG@MIL-100-B composite) using a metal-ligand-fragment coassembly (MLFC) strategy. The composites were then applied as an effective magnetic solid-phase extraction (SPE) sorbent for determination of trace catecholamine concentrations in rat plasma through coupling with HPLC-MS/MS. The obtained nano-composites exhibited high magnetic responsivity, uniform mesopores, large specific surface area, and boronic acid-functionalized inner pore-walls. Catecholamines in rat plasma were extracted through interaction between the cis-diol structures and the boronic acid groups in the MG@MIL-100-B composites. Extraction conditions were optimized by studying SPE parameters including adsorption and desorption time, elution solvent type, pH conditions and adsorbent amount. With our approach, the detection limits (S/N = 3) were as low as 0.005 ng mL-1 for DA and E, and 0.02 ng mL-1 for NE. Intra- and inter-day precision ranged from 2.84-6.63% (n = 6) and 5.70-11.44% (n = 6), respectively. Recoveries from spiking experiments also showed satisfactory results of 94.40-109.51%. Finally, the MG@MIL-100-B composites were applied successfully to determine catecholamine concentrations in rat plasma.
Collapse
Affiliation(s)
- Xinying He
- Pharmaceutical Analysis Department, School of Pharmacy, Fudan University Shanghai 201203 China +86-21-51980057 +86-21-51980057
| | - Yunqiu Yu
- Pharmaceutical Analysis Department, School of Pharmacy, Fudan University Shanghai 201203 China +86-21-51980057 +86-21-51980057
| | - Yan Li
- Pharmaceutical Analysis Department, School of Pharmacy, Fudan University Shanghai 201203 China +86-21-51980057 +86-21-51980057
- Fudan University Affiliated Pudong Medical Center, Fudan University Shanghai China
| |
Collapse
|
11
|
LC–MS/MS Determination of Catecholamines in Urine Using FMOC-Cl Derivatization on Solid-Phase Extraction Cartridge. Chromatographia 2018. [DOI: 10.1007/s10337-018-3610-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
12
|
Josypčuk O, Barek J, Josypčuk B. Amperometric Determination of Catecholamines by Enzymatic Biosensors in Flow Systems. ELECTROANAL 2018. [DOI: 10.1002/elan.201800078] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- Oksana Josypčuk
- J. Heyrovsky Institute of Physical Chemistry of the CAS; v.v.i. Dolejskova 3 182 23 Prague 8 Czech Republic
| | - Jiří Barek
- Charles University; Faculty of Science, Department of Analytical Chemistry, UNESCO Laboratory of Environmental Electrochemistry; Hlavova 2030/8 128 43 Prague 2 Czech Republic
| | - Bohdan Josypčuk
- J. Heyrovsky Institute of Physical Chemistry of the CAS; v.v.i. Dolejskova 3 182 23 Prague 8 Czech Republic
| |
Collapse
|
13
|
Shen Y, Cheng L, Guan Q, Li H, Lu J, Wang X. Development and validation of a liquid chromatography tandem mass spectrometry method for the measurement of urinary catecholamines in diagnosis of pheochromocytoma. Biomed Chromatogr 2017; 31. [PMID: 28481409 DOI: 10.1002/bmc.4003] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2017] [Revised: 04/26/2017] [Accepted: 05/04/2017] [Indexed: 11/10/2022]
Abstract
The measurement of catecholamines in human body fluids is requested frequently for the differential diagnosis and monitoring of pheochromocytoma. The methods in most clinical laboratories focus on high-performance liquid chromatography coupled with electrochemical detection, which suffers from high background noise, low sensitivity, and poor separation. We reported and developed a robust high-throughput liquid chromatography tandem mass spectrometry method in routine clinical laboratories for the measurement of urinary catecholamines for diagnosis of pheochromocytoma. The method was validated for consistent linearity, good recovery (88-112%), excellent stability and low carryover. Intra- and inter-assay precision values for catecholamines were all below 3.35 and 4.83% respectively. Dilution linearity was investigated with satisfactory linearly dependent coefficients (r > 0.9988). The reference intervals were obtained from 310 results derived from patients in which the diagnosis of pheochromocytoma was excluded. This method was successfully used in our laboratory. The clinical characteristics of patients have been explored with satisfactory sensitivity and specificity. Therefore, we have developed a reliable assay for the liquid chromatography tandem mass spectrometry measurement of catecholamines in a routine clinical laboratory. The assay requires a small volume of urine, and all analytes are measured simultaneously. The assay is rapid and reliable to be executed, offering the potential for routine clinical laboratories.
Collapse
Affiliation(s)
- Ying Shen
- Department of Laboratory Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People's Republic of China
| | - Liming Cheng
- Department of Laboratory Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People's Republic of China
| | - Qing Guan
- Department of Laboratory Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People's Republic of China
| | - Huijun Li
- Department of Laboratory Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People's Republic of China
| | - Jie Lu
- Department of Laboratory Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People's Republic of China
| | - Xu Wang
- Department of Laboratory Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People's Republic of China
| |
Collapse
|
14
|
Nyssen L, Delanaye P, Le Goff C, Peeters S, Cavalier É. A simple LC-MS method for the determination of iohexol and iothalamate in serum, using ioversol as an internal standard. Clin Chim Acta 2016; 463:96-102. [DOI: 10.1016/j.cca.2016.10.021] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Revised: 10/14/2016] [Accepted: 10/14/2016] [Indexed: 12/31/2022]
|
15
|
Janků S, Komendová M, Urban J. Development of an online solid-phase extraction with liquid chromatography method based on polymer monoliths for the determination of dopamine. J Sep Sci 2016; 39:4107-4115. [DOI: 10.1002/jssc.201600818] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2016] [Revised: 08/24/2016] [Accepted: 08/24/2016] [Indexed: 01/18/2023]
Affiliation(s)
- Simona Janků
- Department of Analytical Chemistry, Faculty of Chemical Technology; University of Pardubice; Studentstká 573 Pardubice Czech Republic
| | - Martina Komendová
- Department of Analytical Chemistry, Faculty of Chemical Technology; University of Pardubice; Studentstká 573 Pardubice Czech Republic
| | - Jiří Urban
- Department of Analytical Chemistry, Faculty of Chemical Technology; University of Pardubice; Studentstká 573 Pardubice Czech Republic
| |
Collapse
|
16
|
Alhendal A, Mengis S, Matthews J, Malik A. Nonhydrolytic sol-gel approach to facile creation of surface-bonded zirconia organic-inorganic hybrid coatings for sample preparation. Ι. Capillary microextraction of catecholamine neurotransmitters. J Chromatogr A 2016; 1468:23-32. [DOI: 10.1016/j.chroma.2016.09.036] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2016] [Revised: 09/12/2016] [Accepted: 09/19/2016] [Indexed: 10/21/2022]
|
17
|
Identification of catecholamine neurotransmitters using fluorescence sensor array. Anal Chim Acta 2016; 917:85-92. [DOI: 10.1016/j.aca.2016.02.037] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Revised: 02/24/2016] [Accepted: 02/27/2016] [Indexed: 02/07/2023]
|
18
|
Abstract
The idiopathic inflammatory bowel diseases, which include Crohn's disease and ulcerative colitis, are multifactorial chronic conditions that result in numerous perturbations of metabolism in the gastrointestinal mucosa. Thus, methodologies for the qualitative and quantitative analysis of small molecule metabolites in mucosal tissues are important for further elucidation of mechanisms driving inflammation and the metabolic consequences of inflammation. High-performance liquid chromatography (HPLC) is a ubiquitous analytical technique that can be adapted for both targeted and non-targeted metabolomic analysis. Here, protocols for reversed-phase (RP) HPLC-based methods using two different detection modalities are presented. Ultraviolet detection is used for the analysis of adenine nucleotide metabolites, whereas electrochemical detection is used for the analysis of multiple amino acid metabolites. These methodologies provide platforms for further characterization of the metabolic changes that occur during gastrointestinal inflammation.
Collapse
Affiliation(s)
- Daniel J Kao
- Department of Medicine, The University of Colorado School of Medicine, Aurora, CO, USA
- Mucosal Inflammation Program, The University of Colorado School of Medicine, Aurora, CO, USA
| | - Jordi M Lanis
- Department of Medicine, The University of Colorado School of Medicine, Aurora, CO, USA
- Mucosal Inflammation Program, The University of Colorado School of Medicine, Aurora, CO, USA
| | - Erica Alexeev
- Department of Medicine, The University of Colorado School of Medicine, Aurora, CO, USA
- Mucosal Inflammation Program, The University of Colorado School of Medicine, Aurora, CO, USA
| | - Douglas J Kominsky
- Department of Microbiology and Immunology, Montana State University, Lewis Hall 109, Bozeman, MT, 59717, USA.
| |
Collapse
|
19
|
Chen J, Dai Z, Lei Q, Yan S, Wang Y, Wang X. Effects of huwentoxin-I on catecholamines in cultured PC12 cells. Toxicol Mech Methods 2015; 25:241-8. [DOI: 10.3109/15376516.2015.1008287] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
20
|
Florentinus-Mefailoski A, Soosaipillai A, Dufresne J, Diamandis EP, Marshall JG. An enzyme-linked immuno-mass spectrometric assay with the substrate adenosine monophosphate. Anal Bioanal Chem 2014; 407:1119-30. [PMID: 25519722 DOI: 10.1007/s00216-014-8323-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2014] [Revised: 10/29/2014] [Accepted: 11/05/2014] [Indexed: 01/22/2023]
Abstract
An enzyme-linked immuno-mass spectrometric assay (ELIMSA) with the specific detection probe streptavidin conjugated to alkaline phosphatase catalyzed the production of adenosine from the substrate adenosine monophosphate (AMP) for sensitive quantification of prostate-specific antigen (PSA) by mass spectrometry. Adenosine ionized efficiently and was measured to the femtomole range by dilution and direct analysis with micro-liquid chromatography, electrospray ionization, and mass spectrometry (LC-ESI-MS). The LC-ESI-MS assay for adenosine production was shown to be linear and accurate using internal (13)C(15)N adenosine isotope dilution, internal (13)C(15)N adenosine one-point calibration, and external adenosine standard curves with close agreement. The detection limits of LC-ESI-MS for alkaline phosphatase-streptavidin (AP-SA, ∼190,000 Da) was tested by injecting 0.1 μl of a 1 pg/ml solution, i.e., 100 attograms or 526 yoctomole (5.26E-22) of the alkaline-phosphatase labeled probe on column (about 315 AP-SA molecules). The ELIMSA for PSA was linear and showed strong signals across the picogram per milliliter range and could robustly detect PSA from all of the prostatectomy patients and all of the female plasma samples that ranged as low as 70 pg/ml with strong signals well separated from the background and well within the limit of quantification of the AP-SA probe. The results of the ELIMSA assay for PSA are normal and homogenous when independently replicated with a fresh standard over multiple days, and intra and inter diem assay variation was less than 10 % of the mean. In a blind comparison, ELIMSA showed excellent agreement with, but was more sensitive than, the present gold standard commercial fluorescent ELISA, or ECL-based detection, of PSA from normal and prostatectomy samples, respectively.
Collapse
|
21
|
Florentinus-Mefailoski A, Marshall JG. Pyridoxamine-5-phosphate enzyme-linked immune mass spectrometric assay substrate for linear absolute quantification of alkaline phosphatase to the yoctomole range applied to prostate specific antigen. Anal Chem 2014; 86:10684-91. [PMID: 25259405 DOI: 10.1021/ac502572a] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
There is a need to measure proteins that are present in concentrations below the detection limits of existing colorimetric approaches with enzyme-linked immunoabsorbent assays (ELISA). The powerful enzyme alkaline phosphatase conjugated to the highly specific bacterial protein streptavidin binds to biotinylated macromolecules like proteins, antibodies, or other ligands and receptors with a high affinity. The binding of the biotinylated detection antibody, with resulting amplification of the signal by the catalytic production of reporter molecules, is key to the sensitivity of ELISA. The specificity and amplification of the signal by the enzyme alkaline phosphatase in ELISA together with the sensitivity of liquid chromatography electrospray ionization and mass spectrometry (LC-ESI-MS) to detect femtomole to picomole amounts of reporter molecules results in an ultrasensitive enzyme-linked immune mass spectrometric assay (ELIMSA). The novel ELIMSA substrate pyridoxamine-5-phosphate (PA5P) is cleaved by the enzyme alkaline phosphatase to yield the basic and hydrophilic product pyridoxamine (PA) that elutes rapidly with symmetrical peaks and a flat baseline. Pyridoxamine (PA) and (13)C PA were both observed to show a linear relationship between log ion intensity and quantity from picomole to femtomole amounts by liquid chromatography-electrospray ionization and mass spectrometry. Four independent methods, (i) internal (13)C isotope PA dilution curves, (ii) internal (13)C isotope one-point calibration, (iii) external PA standard curve, and (iv) external (13)C PA standard curve, all agreed within 1 digit in the same order of magnitude on the linear quantification of PA. Hence, a mass spectrometer can be used to robustly detect 526 ymol of the alkaline phosphatase streptavidin probe and accurately quantify zeptomole amounts of PSA against log linear absolute standard by micro electrospray on a simple ion trap.
Collapse
|
22
|
Mu C, Zhang Q, Wu D, Zhang Y, Zhang Q. Simultaneous quantification of catecholamines in rat brain by high-performance liquid chromatography with on-line gold nanoparticle-catalyzed luminol chemiluminescence detection. Biomed Chromatogr 2014; 29:148-55. [DOI: 10.1002/bmc.3252] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2013] [Revised: 04/07/2014] [Accepted: 04/18/2014] [Indexed: 11/06/2022]
Affiliation(s)
- Chunlei Mu
- School of Pharmacy; Anhui Medical University; Hefei 230032 People's Republic of China
| | - Qi Zhang
- School of Pharmacy; Anhui Medical University; Hefei 230032 People's Republic of China
| | - Dong Wu
- School of Pharmacy; Anhui Medical University; Hefei 230032 People's Republic of China
| | - Yunjing Zhang
- School of Pharmacy; Anhui University of Chinese Medicine; Hefei 230031 People's Republic of China
| | - Qunlin Zhang
- School of Pharmacy; Anhui Medical University; Hefei 230032 People's Republic of China
| |
Collapse
|
23
|
Prasad BB, Srivastava A, Prasad A, Tiwari MP. Molecularly imprinted micro solid-phase extraction technique coupled with complementary molecularly imprinted polymer-sensor for ultra trace analysis of epinephrine in real samples. Colloids Surf B Biointerfaces 2014; 113:69-76. [DOI: 10.1016/j.colsurfb.2013.08.046] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2013] [Revised: 08/12/2013] [Accepted: 08/16/2013] [Indexed: 01/21/2023]
|
24
|
Naccarato A, Gionfriddo E, Sindona G, Tagarelli A. Development of a simple and rapid solid phase microextraction-gas chromatography-triple quadrupole mass spectrometry method for the analysis of dopamine, serotonin and norepinephrine in human urine. Anal Chim Acta 2013; 810:17-24. [PMID: 24439500 DOI: 10.1016/j.aca.2013.11.058] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 11/22/2013] [Accepted: 11/29/2013] [Indexed: 12/29/2022]
Abstract
The work aims at developing a simple and rapid method for the quantification of dopamine (DA), serotonin (5-HT) and norepinephrine (NE) in human urine. The urinary levels of these biogenic amines can be correlated with several pathological conditions concerning heart disease, stress, neurological disorders and cancerous tumors. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) after a fast derivatization of both aliphatic amino and phenolic moieties by propyl chloroformate. The variables influencing the derivatization reaction were reliably optimized by the multivariate approach of "Experimental design". The optimal conditions were obtained by performing derivatization with 100μL of propyl chloroformate and 100μL of pyridine. The extraction ability of five commercially available SPME fibers was evaluated in univariate mode and the best results were obtained using the polyacrylate fiber. The variables affecting the efficiency of SPME analysis were again optimized by the multivariate approach of "Experimental design" and, in particular, a central composite design (CCD) was applied. The optimal values were extraction in 45min at room temperature, desorption temperature at 300°C, no addition of NaCl. Assay of derivatized analytes was performed by using a gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) system in selected reaction monitoring (SRM) acquisition. An evaluation of all analytical parameters demonstrates that the developed method provides satisfactory results. Indeed, very good linearities were achieved in the tested calibration range with correlation coefficient values of 0.9995, 0.9999 and 0.9997 for DA, 5-HT and NE, respectively. Accuracies and RSDs calculated for between-run and tested at concentrations of 30, 200, and 800μg L(-1) were in the range from 92.8% to 103.0%, and from 0.67 to 4.5%, respectively. Finally, the LOD values obtained can be considered very good (0.587, 0.381 and 1.23μg L(-1) for DA, 5-HT and NE, respectively).
Collapse
Affiliation(s)
- Attilio Naccarato
- Dipartimento di Chimica e Tecnologie Chimiche, Università della Calabria, Via P. Bucci Cubo 12/C, Arcavacata di Rende (CS), I-87030 Cosenza, Italy
| | - Emanuela Gionfriddo
- Dipartimento di Chimica e Tecnologie Chimiche, Università della Calabria, Via P. Bucci Cubo 12/C, Arcavacata di Rende (CS), I-87030 Cosenza, Italy
| | - Giovanni Sindona
- Dipartimento di Chimica e Tecnologie Chimiche, Università della Calabria, Via P. Bucci Cubo 12/C, Arcavacata di Rende (CS), I-87030 Cosenza, Italy
| | - Antonio Tagarelli
- Dipartimento di Chimica e Tecnologie Chimiche, Università della Calabria, Via P. Bucci Cubo 12/C, Arcavacata di Rende (CS), I-87030 Cosenza, Italy.
| |
Collapse
|
25
|
Profiling analysis of biogenic amines and their acidic metabolites in mouse brain tissue using gas chromatography–tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 940:94-103. [DOI: 10.1016/j.jchromb.2013.09.026] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2013] [Revised: 09/16/2013] [Accepted: 09/20/2013] [Indexed: 11/19/2022]
|
26
|
Liu Y, Li N, Ma L, Huang L, Jing S, Zhao L, Feng W. DETERMINATION OF DIETHYLSTILBESTROL IN HUMAN PLASMA WITH MEASUREMENT UNCERTAINTY ESTIMATION BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY. J LIQ CHROMATOGR R T 2013. [DOI: 10.1080/10826076.2012.745140] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Yi Liu
- a Department of Pharmacy , Peking University People's Hospital , Beijing , P.R. China
| | - Na Li
- b Central laboratory, Peking University People's Hospital , Beijing , P.R. China
| | - Liping Ma
- b Central laboratory, Peking University People's Hospital , Beijing , P.R. China
| | - Lin Huang
- a Department of Pharmacy , Peking University People's Hospital , Beijing , P.R. China
| | - Shan Jing
- c Department of Cardiology , Peking University People's Hospital , Beijing , P.R. China
| | - Libo Zhao
- a Department of Pharmacy , Peking University People's Hospital , Beijing , P.R. China
| | - Wanyu Feng
- a Department of Pharmacy , Peking University People's Hospital , Beijing , P.R. China
| |
Collapse
|
27
|
Filee R, Schoos R, Boemer F. Evaluation of physiological amino acids profiling by tandem mass spectrometry. JIMD Rep 2013; 13:119-28. [PMID: 24190798 PMCID: PMC4110342 DOI: 10.1007/8904_2013_265] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2013] [Revised: 08/30/2013] [Accepted: 09/09/2013] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Nowadays, the most conventional method to quantify physiological amino acids consists in ion exchange chromatography (IEC) followed by post-column ninhydrin derivatization and UV detection at two wavelengths. Unfortunately, the technique presents some drawbacks such as long run time, large sample volume, and specific costs associated to the maintenance of a dedicated instrument. Therefore, we aimed to switch towards a mass spectrometry approach. METHODS We have tested the aTRAQ kit for Amino Acid Analysis of Physiological Fluids (AB Sciex), affording the selective quantification of about 40 amino acids, and present here the results of our assessments. RESULTS Outlined accuracy profiles for each amino acid demonstrated very reliable data. A good linearity was observed from 1 to 1,000 μmol/L. RESULTS comparison with IEC showed a right concordance. Reference intervals established were very similar to those obtained by IEC and patients suffering from inborn error of metabolism have been readily identified. CONCLUSIONS The present approach offers a valid alternative to the IEC method, with several advantages: lower sample volume, run time reduction, and improved specificity. However, the aTRAQ method requires minute data reviewing, expending the overall time of procedure. Finally, financial and practical considerations of both techniques have to be counterbalanced before engaging any transition.
Collapse
Affiliation(s)
- Romain Filee
- />Biochemical Genetics Laboratory, Human Genetics, CHU Liege, University of Liege, Liege, Belgium
| | - Roland Schoos
- />Biochemical Genetics Laboratory, Human Genetics, CHU Liege, University of Liege, Liege, Belgium
| | - François Boemer
- />Biochemical Genetics Laboratory, Human Genetics, CHU Liege, University of Liege, Liege, Belgium
- />Biochemical Genetics Laboratory, CHU Sart-Tilman, University of Liege, 4000 Liege, Belgium
| |
Collapse
|
28
|
Liquid chromatographic methods for the quantification of catecholamines and their metabolites in several biological samples—A review. Anal Chim Acta 2013; 768:12-34. [DOI: 10.1016/j.aca.2012.12.030] [Citation(s) in RCA: 129] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2012] [Revised: 12/16/2012] [Accepted: 12/19/2012] [Indexed: 11/18/2022]
|
29
|
Xu X, Zhang H, Shi H, Ma C, Cong B, Kang W. Determination of three major catecholamines in human urine by capillary zone electrophoresis with chemiluminescence detection. Anal Biochem 2012; 427:10-7. [DOI: 10.1016/j.ab.2012.04.022] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2012] [Revised: 04/18/2012] [Accepted: 04/19/2012] [Indexed: 10/28/2022]
|
30
|
Bouabidi A, Talbi M, Bourichi H, Bouklouze A, El Karbane M, Boulanger B, Brik Y, Hubert P, Rozet E. Flexibility and applicability of β-expectation tolerance interval approach to assess the fitness of purpose of pharmaceutical analytical methods. Drug Test Anal 2012; 4:1014-27. [PMID: 22615163 DOI: 10.1002/dta.1345] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2011] [Revised: 02/06/2012] [Accepted: 02/27/2012] [Indexed: 11/10/2022]
Abstract
An innovative versatile strategy using Total Error has been proposed to decide about the method's validity that controls the risk of accepting an unsuitable assay together with the ability to predict the reliability of future results. This strategy is based on the simultaneous combination of systematic (bias) and random (imprecision) error of analytical methods. Using validation standards, both types of error are combined through the use of a prediction interval or β-expectation tolerance interval. Finally, an accuracy profile is built by connecting, on one hand all the upper tolerance limits, and on the other hand all the lower tolerance limits. This profile combined with pre-specified acceptance limits allows the evaluation of the validity of any quantitative analytical method and thus their fitness for their intended purpose. In this work, the approach of accuracy profile was evaluated on several types of analytical methods encountered in the pharmaceutical industrial field and also covering different pharmaceutical matrices. The four studied examples depicted the flexibility and applicability of this approach for different matrices ranging from tablets to syrups, different techniques such as liquid chromatography, or UV spectrophotometry, and for different categories of assays commonly encountered in the pharmaceutical industry i.e. content assays, dissolution assays, and quantitative impurity assays. The accuracy profile approach assesses the fitness of purpose of these methods for their future routine application. It also allows the selection of the most suitable calibration curve, the adequate evaluation of a potential matrix effect and propose efficient solution and the correct definition of the limits of quantification of the studied analytical procedures.
Collapse
Affiliation(s)
- A Bouabidi
- Analytical Chemistry Laboratory, CIRM, Institute of Pharmacy, University of Liège, Belgium
| | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Development and validation of a rapid HPLC method for the determination of cefdinir in beagle dog plasma integrated with an automatic on-line solid-phase extraction following protein precipitation in the 96-well plate format. J Chromatogr B Analyt Technol Biomed Life Sci 2012; 895-896:83-8. [DOI: 10.1016/j.jchromb.2012.03.018] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2011] [Revised: 03/05/2012] [Accepted: 03/10/2012] [Indexed: 11/30/2022]
|
32
|
Zhu P, Bowden P, Zhang D, Marshall JG. Mass spectrometry of peptides and proteins from human blood. MASS SPECTROMETRY REVIEWS 2011; 30:685-732. [PMID: 24737629 DOI: 10.1002/mas.20291] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2008] [Revised: 12/09/2009] [Accepted: 01/19/2010] [Indexed: 06/03/2023]
Abstract
It is difficult to convey the accelerating rate and growing importance of mass spectrometry applications to human blood proteins and peptides. Mass spectrometry can rapidly detect and identify the ionizable peptides from the proteins in a simple mixture and reveal many of their post-translational modifications. However, blood is a complex mixture that may contain many proteins first expressed in cells and tissues. The complete analysis of blood proteins is a daunting task that will rely on a wide range of disciplines from physics, chemistry, biochemistry, genetics, electromagnetic instrumentation, mathematics and computation. Therefore the comprehensive discovery and analysis of blood proteins will rank among the great technical challenges and require the cumulative sum of many of mankind's scientific achievements together. A variety of methods have been used to fractionate, analyze and identify proteins from blood, each yielding a small piece of the whole and throwing the great size of the task into sharp relief. The approaches attempted to date clearly indicate that enumerating the proteins and peptides of blood can be accomplished. There is no doubt that the mass spectrometry of blood will be crucial to the discovery and analysis of proteins, enzyme activities, and post-translational processes that underlay the mechanisms of disease. At present both discovery and quantification of proteins from blood are commonly reaching sensitivities of ∼1 ng/mL.
Collapse
Affiliation(s)
- Peihong Zhu
- Department of Chemistry and Biology, Ryerson University, 350 Victoria Street, Toronto, Ontario, Canada M5B 2K3
| | | | | | | |
Collapse
|
33
|
Current status and future developments of LC-MS/MS in clinical chemistry for quantification of biogenic amines. Clin Biochem 2011; 44:95-103. [DOI: 10.1016/j.clinbiochem.2010.07.006] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2010] [Revised: 07/01/2010] [Accepted: 07/04/2010] [Indexed: 02/07/2023]
|
34
|
Wang S, Fan L, Zhou W. Sensitive Analysis of 5-(4,6-Dichloro-s-triazin-2-ylamino)fluorescein-Labeled Catecholamines by Mixed MEKC–LIF. Chromatographia 2010. [DOI: 10.1365/s10337-010-1796-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
35
|
Ko J, Kwak BM, Ahn JH, Jeong SH, Shim SL, Kim KS, Yoon T, Dong-gil L, Jeong J. LC-UV Column-Switching for Quantitation of Vitamin K1 in Infant Formula. Chromatographia 2010. [DOI: 10.1365/s10337-010-1722-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
36
|
Validation of a fast gas chromatographic method for the study of semiochemical slow release formulations. J Pharm Biomed Anal 2010; 53:962-72. [PMID: 20688452 DOI: 10.1016/j.jpba.2010.07.014] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2010] [Revised: 07/08/2010] [Accepted: 07/13/2010] [Indexed: 11/21/2022]
Abstract
The validation of a fast GC-FID analytical method for the quantitative determination of semiochemical sesquiterpenes (E-beta-farnesene and beta-caryophyllene) to be used in an integrated pest management approach is described. Accuracy profiles using total error as decision criteria for validation were used to verify the overall accuracy of the method results within a well defined range of concentrations and to determine the lowest limit of quantification for each analyte. Furthermore it allowed to select a very simple and reliable regression model for calibration curve for the quantification of both analytes as well as to provide measurement uncertainty without any additional experiments. Finally, this validated method was used for the quantification of semiochemicals in slow release formulations. The goal was to verify the protection efficiency of alginate gel beads formulations against oxidation and degradation of sesquiterpenes. The results showed that the alginate beads are adequate slow release devices which protect the bio-active molecules during at least twenty days.
Collapse
|
37
|
de Jong WH, de Vries EG, Wolffenbuttel BH, Kema I. Automated mass spectrometric analysis of urinary free catecholamines using on-line solid phase extraction. J Chromatogr B Analyt Technol Biomed Life Sci 2010; 878:1506-12. [DOI: 10.1016/j.jchromb.2010.03.050] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2009] [Revised: 03/19/2010] [Accepted: 03/31/2010] [Indexed: 11/27/2022]
|
38
|
Zhang X, Zhao X, Zhang C, Yang L, Xiong X, Zhou Y, Yang Y, Duan J. Accuracy Profile Theory for the Validation of an LC–MS-MS Method for the Determination of Risperidone and 9-Hydroxyrisperidone in Human Plasma. Chromatographia 2010. [DOI: 10.1365/s10337-010-1580-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
39
|
Zhang X, Duan J, Zhai S, Yang Y, Yang L. Performance of tiloronoxim and tilorone determination in human blood by HPLC-MS/MS: method validation, uncertainty assessment and its application to a pharmacokinetic study. J Chromatogr B Analyt Technol Biomed Life Sci 2010; 878:492-6. [PMID: 20044316 DOI: 10.1016/j.jchromb.2009.12.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2009] [Revised: 12/10/2009] [Accepted: 12/10/2009] [Indexed: 11/28/2022]
Abstract
A highly sensitive and selective HPLC-MS/MS method is presented for the quantitative determination of tiloronoxim and its metabolite tilorone in human blood. An aliquot of 200 microl human blood was extracted with a mixture of chloroform/ethyl ether (1/2, v/v), using metoprolol as the internal standard (the IS). Separation was achieved on an Xterra MS C18 column (50 mm x 2.1 mm, 5 microm) with a gradient mobile phase of methanol/water containing 15 mM ammonium bicarbonate (pH 10.5). Detection was performed using positive MRM mode on a TurboIonSpray source. The mass transitions monitored were m/z 426.3-->100.0, m/z 411.3-->100.0 and m/z 268.3-->116.1 for tiloronoxim, tilorone and the IS, respectively. The method was fully validated using total error theory, which is based on beta-expectation tolerance intervals and include trueness and intermediate precision. The method was found to be accurate over a concentration range of 1-100 ng/ml for both compounds. The measurement uncertainty based on beta-expectation tolerance intervals was assessed at each concentration level of the validation standards. This method was successively applied to a pharmacokinetic study of tiloronoxim in healthy volunteers.
Collapse
Affiliation(s)
- Xianhua Zhang
- Department of Pharmacy, Peking University Third Hospital, 49 North Garden Rd., Beijing 100191, PR China
| | | | | | | | | |
Collapse
|
40
|
Kim J, Park H, Ryu J, Jeon O, Paeng IR. COMPETITIVE ENZYME-LINKED IMMUNOSORBENT ASSAY FOR A SELECTIVE AND SENSITIVE DETERMINATION OF DOPAMINE IN THE PRESENCE OF ASCORBIC ACID AND URIC ACID. J Immunoassay Immunochem 2009; 31:33-44. [DOI: 10.1080/15321810903404988] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
41
|
Eggink M, Charret S, Wijtmans M, Lingeman H, Kool J, Niessen WMA, Irth H. Development of an on-line weak-cation exchange liquid chromatography-tandem mass spectrometric method for screening aldehyde products in biological matrices. J Chromatogr B Analyt Technol Biomed Life Sci 2009; 877:3937-45. [PMID: 19880357 DOI: 10.1016/j.jchromb.2009.09.043] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2009] [Revised: 09/27/2009] [Accepted: 09/28/2009] [Indexed: 10/20/2022]
Abstract
This paper focuses on the development and optimization of an on-line weak-cation exchange SPE (WCXE) coupled to gradient HPLC with tandem MS detection. The system enables the selective purification and re-concentration of the in-vial derivatized aldehydes from plasma and urine samples. Aldehydes are important as biomarkers for oxidative stress. Using a derivatization cocktail consisting of 4-(2-(trimethylammonio)ethoxy)benzenaminium dibromide (4-APC) and NaBH3CN in the screening and detection of known and unknown aldehyde biomarkers, one can take advantage of the specific fragmentation characteristics of this derivatization reagent in MS/MS. The WCXE column gives the advantages of direct injection of the sample after protein precipitation and centrifugation into the WCXE-LC-MS/MS system. Injection volumes up to 50 microl can be injected without overloading the WCX column. Detection limits of 0.5 nM can be reached for the detection of the derivatized aldehydes. The system is robust with low intra-/inter-day variation in retention time and peak area. An in vitro model shows how derivatized aldehydes in human and rat plasma are detected. Finally, plasma treated with radical inducer shows elevated aldehyde species compared to untreated plasma.
Collapse
Affiliation(s)
- Mark Eggink
- VU University Amsterdam, Faculty of Science, Section of Analytical Chemistry and Applied Spectroscopy, De Boelelaan 1083, 1081 HV Amsterdam, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
42
|
Ferreira FD, Silva LI, Freitas A, Rocha-Santos TA, Duarte A. High performance liquid chromatography coupled to an optical fiber detector coated with laccase for screening catecholamines in plasma and urine. J Chromatogr A 2009; 1216:7049-54. [DOI: 10.1016/j.chroma.2009.08.067] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2009] [Revised: 08/19/2009] [Accepted: 08/27/2009] [Indexed: 12/01/2022]
|
43
|
Rozet E, Dewé W, Ziemons E, Bouklouze A, Boulanger B, Hubert P. Methodologies for the transfer of analytical methods: A review. J Chromatogr B Analyt Technol Biomed Life Sci 2009; 877:2214-23. [PMID: 19144574 DOI: 10.1016/j.jchromb.2008.12.049] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2008] [Revised: 12/05/2008] [Accepted: 12/19/2008] [Indexed: 12/01/2022]
Affiliation(s)
- E Rozet
- Laboratory of Analytical Chemistry, CIRM, Department of Pharmacy, University of Liège, B-4000 Liège, Belgium
| | | | | | | | | | | |
Collapse
|
44
|
Restricted-access media supports for direct high-throughput analysis of biological fluid samples: review of recent applications. Bioanalysis 2009; 1:577-94. [DOI: 10.4155/bio.09.39] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
This review presents an update on the use of restricted-access materials (RAMs) for direct injection of biological samples. The fundamental improvements in the preparation of tailored RAMs and the diversity of applications with these phases are presented. Insights into diminishing the matrix effect by the use of RAM supports in methods by LC–MS and into the low number of methods for enantiomeric separations by direct injections of biological samples are addressed. The diversity of systems that incorporate RAMs for selective sample clean-up or fractionation in proteome and peptidome analysis is also covered.
Collapse
|
45
|
Moisture content determination of pharmaceutical pellets by near infrared spectroscopy: Method development and validation. Anal Chim Acta 2009; 642:186-92. [DOI: 10.1016/j.aca.2008.12.031] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2008] [Revised: 12/12/2008] [Accepted: 12/16/2008] [Indexed: 11/22/2022]
|
46
|
Prasad BB, Tiwari K, Singh M, Sharma PS, Patel AK, Srivastava S. Ultratrace Analysis of Dopamine Using a Combination of Imprinted Polymer-Brush-Coated SPME and Imprinted Polymer Sensor Techniques. Chromatographia 2009. [DOI: 10.1365/s10337-009-1039-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
47
|
Boemer F, Bours V, Schoos R, Hubert P, Rozet E. Analytical validation based on total error measurement and cut-off interpretation of a neonatal screening TSH-immunoassay. J Chromatogr B Analyt Technol Biomed Life Sci 2008; 877:2412-7. [PMID: 19036650 DOI: 10.1016/j.jchromb.2008.11.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2008] [Revised: 11/05/2008] [Accepted: 11/05/2008] [Indexed: 11/30/2022]
Abstract
To prevent the severe developmental and physical morbidities associated with congenital hypothyroidism, we developed a home-made Enzyme-Linked Immunosorbent Assay (ELISA) method to quantify Thyroid Stimulating Hormone (TSH) levels on newborn dried blood spots. In order to agree with actual clinical laboratory quality referential (ISO 15189), we desired to update our analytical validation protocol. For this purpose, an approach using accuracy profiles based on tolerance intervals for the total error measurement was for first time applied to an immunological assay. According to acceptance limits fixed at +/-30%, the method was found accurate over a concentration range from 17.48 to 250 mIU/L. Based on 99.5 percentile of a 16,459 newborn population, cut-off was fixed at 20.1 mIU/L and validated against normal and pathologic neonatal populations. Additionally, uncertainty regions around this value were obtained applying four different approaches. Finally, we demonstrated here our in-house immunological technique fulfils criterions of a neonatal screening policy.
Collapse
Affiliation(s)
- François Boemer
- Laboratoire de Biochimie Génétique, Centre de Génétique Humaine, CHU, University of Liège, Liège, Belgium.
| | | | | | | | | |
Collapse
|
48
|
Wang Y, Lehmann R, Lu X, Zhao X, Xu G. Novel, fully automatic hydrophilic interaction/reversed-phase column-switching high-performance liquid chromatographic system for the complementary analysis of polar and apolar compounds in complex samples. J Chromatogr A 2008; 1204:28-34. [DOI: 10.1016/j.chroma.2008.07.010] [Citation(s) in RCA: 73] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2008] [Revised: 07/03/2008] [Accepted: 07/07/2008] [Indexed: 11/26/2022]
|
49
|
Hubert P, Nguyen-Huu JJ, Boulanger B, Chapuzet E, Cohen N, Compagnon PA, Dewé W, Feinberg M, Laurentie M, Mercier N, Muzard G, Valat L, Rozet E. Harmonization of strategies for the validation of quantitative analytical procedures: a SFSTP proposal part IV. Examples of application. J Pharm Biomed Anal 2008; 48:760-71. [PMID: 18768284 DOI: 10.1016/j.jpba.2008.07.018] [Citation(s) in RCA: 106] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2008] [Accepted: 07/21/2008] [Indexed: 11/27/2022]
Abstract
A harmonized approach for the validation of analytical methods based on accuracy profile was introduced by a SFSTP commission on the validation of analytical procedure. This fourth and last document aims at illustrating this methodology and the statistics used. Therefore the validation of real case methods are proposed such as methods for the quality control of drugs, for the quantitation of impurities in drug substances, for bioanalysis or for the determination of nutriments. Furthermore, different types of analytical methods are used in order to demonstrate the applicability of the proposed approach to a wide range of methods such as liquid chromatography (LC-UV, LC-MS), spectrophotometry or ELISA.
Collapse
Affiliation(s)
- Ph Hubert
- Laboratory of Analytical Chemistry, Bioanalytical Chemistry Research Unit, Institute of Pharmacy, University of Liège, CHU, B36, B-4000 Liège, Belgium.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Cavalier E, Rozet E, Dubois N, Charlier C, Hubert P, Chapelle JP, Krzesinski JM, Delanaye P. Performance of iohexol determination in serum and urine by HPLC: validation, risk and uncertainty assessment. Clin Chim Acta 2008; 396:80-5. [PMID: 18687322 DOI: 10.1016/j.cca.2008.07.011] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2008] [Revised: 07/01/2008] [Accepted: 07/13/2008] [Indexed: 12/13/2022]
Abstract
BACKGROUND Determination of glomerular filtration rate plays an important role in nephrological practice. Iohexol is a reference marker for glomerular filtration rate determination. It is available and safe. The aim of this study was to develop a simple, efficient and easy to use analytical method for the quantification of iohexol in serum and urine by high performance liquid chromatography and to thoroughly validate this method. METHODS The HPLC method was inspired from the method published by Krutzen. The e.noval software V2.0 (Arlenda, Liège, Belgium) was used to compute all validation results. RESULTS The validation results indicate that the method will give accurate and reliable results for serum values ranging from 12.95 to 1295 microg/ml and for urine values ranging from 86.0 to 4144 microg/ml. In routine practice, iohexol concentrations found in plasma after injection range from 40 to 600 microg/ml. The expected urinary values are much wider. One should not hesitate to dilute urine samples to fit with the validated range over 5000 microg/ml. CONCLUSION This is the first time that a reference method for the determination of GFR is validated with such a rigorous and thorough protocol. Contrary to other GFR markers, iohexol is now strongly validated from an analytical point of view.
Collapse
Affiliation(s)
- Etienne Cavalier
- Department of Clinical Chemistry, University of Liège, CHU Sart-Tilman, B-4000 Liège, Belgium.
| | | | | | | | | | | | | | | |
Collapse
|