1
|
Justo-Vega A, Jinadasa KK, Jayasinghe GDTM, Álvarez-Freire I, Bermejo AM, Bermejo-Barrera P, Moreda-Piñeiro A. Ultrasound assisted membrane-assisted solvent extraction for the simultaneous assessment of some drugs involved in drug-facilitated sexual assaults by liquid chromatography-tandem mass spectrometry. J Chromatogr A 2023; 1706:464284. [PMID: 37572537 DOI: 10.1016/j.chroma.2023.464284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 03/24/2023] [Accepted: 08/04/2023] [Indexed: 08/14/2023]
Abstract
A simple and highly efficient ultrasound assisted membrane-assisted solvent extraction (MASE) pre-treatment method for urine has been developed and validated for the simultaneous determination of twenty-two drugs involved in drug-facilitated sexual assaults (DFSAs) by liquid chromatography-tandem mass spectrometry. MASE was performed with 4.0 mL of urine (pH adjusted at 12), 400 μL of hexane as an organic solvent inside the polypropylene membrane, and ultrasonication (45 kHz, 120 W) for 10 min. A pre-concentration factor of 40 was achieved after evaporation (N2 stream) and re-dissolution in 100 µL of methanol. Analytes were separated using a Zorbax Eclipse Plus C18 column under gradient elution with aqueous 10 mM NH4HCO3 (pH 8.0) and methanol as mobile phases. Matrix-matched calibrations allowed the assessment of DFSA drugs of quite different octanol-water partition coefficients (Ko/w), from 1.32 101 for pregabalin to 2.45 105 for clomipramine (Log P values from 1.12 (pregabalin) to 5.39 (clomipramine)). The limit of detection (LOD) was between 0.0075 to 0.37 µg L-1, with analytical recoveries ranging from 73 to 103%, and relative standard deviations (RSDs) within the 2-20% range. The applicability of the method was demonstrated after analysing urine samples under forensic investigation.
Collapse
Affiliation(s)
- Ana Justo-Vega
- Trace Element, Spectroscopy and Speciation Group (GETEE), Institute of Materials iMATUS, Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Universidade de Santiago de Compostela, Avenida das Ciencias, s/n., Santiago de Compostela 15782, Spain
| | - Kamal K Jinadasa
- Trace Element, Spectroscopy and Speciation Group (GETEE), Institute of Materials iMATUS, Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Universidade de Santiago de Compostela, Avenida das Ciencias, s/n., Santiago de Compostela 15782, Spain
| | - G D Thilini Madurangika Jayasinghe
- Trace Element, Spectroscopy and Speciation Group (GETEE), Institute of Materials iMATUS, Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Universidade de Santiago de Compostela, Avenida das Ciencias, s/n., Santiago de Compostela 15782, Spain
| | - Iván Álvarez-Freire
- Forensic Sciences Institute "Luís Concheiro" (INCIFOR), Department of Pathologic Anatomy and Forensic Sciences, Faculty of Medicine, Universidade de Santiago de Compostela, Rúa de San Francisco, s/n, Santiago de Compostela 15782, Spain
| | - Ana María Bermejo
- Forensic Sciences Institute "Luís Concheiro" (INCIFOR), Department of Pathologic Anatomy and Forensic Sciences, Faculty of Medicine, Universidade de Santiago de Compostela, Rúa de San Francisco, s/n, Santiago de Compostela 15782, Spain
| | - Pilar Bermejo-Barrera
- Trace Element, Spectroscopy and Speciation Group (GETEE), Institute of Materials iMATUS, Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Universidade de Santiago de Compostela, Avenida das Ciencias, s/n., Santiago de Compostela 15782, Spain
| | - Antonio Moreda-Piñeiro
- Trace Element, Spectroscopy and Speciation Group (GETEE), Institute of Materials iMATUS, Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Universidade de Santiago de Compostela, Avenida das Ciencias, s/n., Santiago de Compostela 15782, Spain.
| |
Collapse
|
2
|
Suárez-Oubiña C, Álvarez-Freire I, Cabarcos P, Bermejo AM, Bermejo-Barrera P, Moreda-Piñeiro A. Isolation and quantification of synthetic cannabinoid receptor agonists in human urine using membrane-assisted solvent extraction followed by liquid chromatography-tandem mass spectrometry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:333-342. [PMID: 36594640 DOI: 10.1039/d2ay01491b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
The global market for new psychoactive substances (NPSs) continues to expand, and the range of drugs available on the market has probably never been wider. Synthetic cannabinoids (SCRAs) constitute the largest family of NPSs, and they go unnoticed during illicit drug market control and during routine toxicological-forensic analysis. Membrane-assisted solvent extraction (MASE) has been a novelty proposed for the simultaneous extraction of SCRAs, and urine has been selected as a model forensic-clinical sample. Isolated SCRAs were further determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS). An optimised sample pre-treatment procedure consists of using 400 μL of n-hexane as an extraction phase placed inside a polypropylene (PP) membrane, adjusting the donor phase (urine) at a pH value of 5.9. Extraction was assisted by mechanical (orbital-horizontal) stirring in a temperature-controlled chamber at room temperature for 20 min. n-Hexane extracts were evaporated to dryness and re-suspended in 100 μL of mobile phase, which leads to a pre-concentration factor of 50. Method validation showed analytical recoveries higher than 80% for most SCRAs and repeatability (inter-day and intra-day assays) with RSD values lower than 20%. The proposed method was found to be selective and sensitive and limits of quantification (LOQs) between 0.10 and 1.0 μg L-1 were achieved.
Collapse
Affiliation(s)
- Cristian Suárez-Oubiña
- Trace Element, Spectroscopy and Speciation Group (GETEE), Institute of Materials iMATUS, Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Universidade de Santiago de Compostela, Avenida das Ciencias, s/n, 15782 Santiago de Compostela, Spain.
| | - Iván Álvarez-Freire
- Forensic Sciences Institute "Luís Concheiro" (INCIFOR), Department of Pathologic Anatomy and Forensic Sciences, Faculty of Medicine, Universidade de Santiago de Compostela, Rúa de San Francisco, s/n, 15782 Santiago de Compostela, Spain
| | - Pamela Cabarcos
- Forensic Sciences Institute "Luís Concheiro" (INCIFOR), Department of Pathologic Anatomy and Forensic Sciences, Faculty of Medicine, Universidade de Santiago de Compostela, Rúa de San Francisco, s/n, 15782 Santiago de Compostela, Spain
| | - Ana María Bermejo
- Forensic Sciences Institute "Luís Concheiro" (INCIFOR), Department of Pathologic Anatomy and Forensic Sciences, Faculty of Medicine, Universidade de Santiago de Compostela, Rúa de San Francisco, s/n, 15782 Santiago de Compostela, Spain
| | - Pilar Bermejo-Barrera
- Trace Element, Spectroscopy and Speciation Group (GETEE), Institute of Materials iMATUS, Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Universidade de Santiago de Compostela, Avenida das Ciencias, s/n, 15782 Santiago de Compostela, Spain.
| | - Antonio Moreda-Piñeiro
- Trace Element, Spectroscopy and Speciation Group (GETEE), Institute of Materials iMATUS, Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Universidade de Santiago de Compostela, Avenida das Ciencias, s/n, 15782 Santiago de Compostela, Spain.
| |
Collapse
|
3
|
Bayat M, Tehrani MS, Kobarfard F, Husain SW, Yazdanpanah H. Validation of an Analytical Method for Simultaneous Determination of 18 Persistent Organic Pollutants in Trout Using LLE Extraction and GC-MS/MS. IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH : IJPR 2020; 18:1224-1238. [PMID: 32641934 PMCID: PMC6934947 DOI: 10.22037/ijpr.2019.1100748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Persistent organic pollutants, (POPs), are vast distributed compounds in environment which are recognized as one of the global pollution problems. These groups of materials being dangerous due to their high stability are accumulated in animal tissues and occurring in the food chain. One of the major paths through which persistent organic combinations access to human body is consuming polluted foods, particularly, fishes. Among aquatic animals, trout as one of the mostly consumed fishes in Tehran’s food basket was studied. In this study, two categories of persistent organic pollutants: Organochlorine pesticides (OCPs) including HCB, Dieldrin, Methoxychlor, α-, ϒ-Chlordane, α-, β-Endosulfan and o,p’-DDE, p,p’-DDE, o,p’-DDT, p,p’-DDT and the second group Polychlonitated biphenyls (PCBs) including seven PCB congeners which are called indicator PCBs (IUPAC nos.: 28,52,101,118,138,153 and 180) were determined in trout by GC-MS/MS in MRM monitoring mode and LLE extraction. The average recoveries of OCPs and PCBs at five concentration levels (1, 2, 5, 10 and 20 ng/g for PCBs and 5 times for OCPs) were in the range of 73-112%. The relative standard deviations of POPs in fish were in the range of 1.4-17.9% for all of the concentration levels. The limit of detections (LODs) and the limit of quantitations (LOQs) were between 0.6-8.3 and 2-25 µg/kg, respectively. The results indicated the presence of organochlorine pesticides in trout and the levels of p,p’-DDE and p,p’-DDT were within the range of < LOQ -12.83 and < LOQ -10.2 ng/g ww (wet weight), respectively. According to the results, OCPs residues were lower than maximum residue levels set by European Council Directives.
Collapse
Affiliation(s)
- Mitra Bayat
- Department of Chemistry, Islamic Azad University, Science and Research Branch, Tehran, Iran
| | - Mohammad Saber Tehrani
- Department of Chemistry, Islamic Azad University, Science and Research Branch, Tehran, Iran
| | - Farzad Kobarfard
- Department of Medicinal Chemistry, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran.,Phytochemistry Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Syed Waqif Husain
- Department of Chemistry, Islamic Azad University, Science and Research Branch, Tehran, Iran
| | - Hassan Yazdanpanah
- Food Safety Research Center (FSRC), Shahid Beheshti University of Medical Sciences, Tehran, Iran.,Department of Toxicology and Pharmacology, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
4
|
Feng L, Zhang S, Zhu G, Li M, Liu J. Determination of trace polychlorinated biphenyls and organochlorine pesticides in water samples through large-volume stir bar sorptive extraction method with thermal desorption gas chromatography. J Sep Sci 2017; 40:4583-4590. [DOI: 10.1002/jssc.201700305] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Revised: 09/18/2017] [Accepted: 09/20/2017] [Indexed: 11/10/2022]
Affiliation(s)
- Li Feng
- College of Chemical Engineering; Zhejiang University of Technology; Hangzhou China
- Zhejiang Environmental Monitoring Center; Hangzhou China
| | - Shengjun Zhang
- Zhejiang Environmental Monitoring Center; Hangzhou China
| | - Guohua Zhu
- Zhejiang Environmental Monitoring Center; Hangzhou China
| | - Mufei Li
- Zhejiang Environmental Monitoring Center; Hangzhou China
| | - Jinsong Liu
- Zhejiang Environmental Monitoring Center; Hangzhou China
| |
Collapse
|
5
|
Guo Y, Hu H, Li T, Xue L, Zhang X, Zhong Z, Zhang Y, Jin Y. Primary secondary amine as a sorbent material in dispersive solid‐phase extraction clean‐up for the determination of indicator polychlorinated biphenyls in environmental water samples by gas chromatography with electron capture detection. J Sep Sci 2017. [DOI: 10.1002/jssc.201700315] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Yuanming Guo
- Key Laboratory of Mariculture and Enhancement of Zhejiang Province Marine Fishery Institute of Zhejiang Province Zhoushan P.R. China
| | - Hongmei Hu
- Key Laboratory of Mariculture and Enhancement of Zhejiang Province Marine Fishery Institute of Zhejiang Province Zhoushan P.R. China
| | - Tiejun Li
- Key Laboratory of Mariculture and Enhancement of Zhejiang Province Marine Fishery Institute of Zhejiang Province Zhoushan P.R. China
| | - Lijian Xue
- Key Laboratory of Mariculture and Enhancement of Zhejiang Province Marine Fishery Institute of Zhejiang Province Zhoushan P.R. China
| | - Xiaoning Zhang
- Department of Mathematics, Sciences and Technology Paine College Augusta GA USA
| | - Zhi Zhong
- Key Laboratory of Mariculture and Enhancement of Zhejiang Province Marine Fishery Institute of Zhejiang Province Zhoushan P.R. China
| | - Yurong Zhang
- Key Laboratory of Mariculture and Enhancement of Zhejiang Province Marine Fishery Institute of Zhejiang Province Zhoushan P.R. China
| | - Yanjian Jin
- Key Laboratory of Mariculture and Enhancement of Zhejiang Province Marine Fishery Institute of Zhejiang Province Zhoushan P.R. China
| |
Collapse
|
6
|
Flow injection-based cloud point extraction of phosalone and ethion in seawater of Chabahar Bay and determination by high-performance liquid chromatography: study of use of carbon nanotube and nanofibers as a column filler in flow system. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2017. [DOI: 10.1007/s13738-017-1059-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
7
|
Mousavi MM, Nemati M, Alizadeh Nabili AA, mahmoudpour M, Arefhosseini S. Application of dispersive liquid–liquid microextraction followed by gas chromatography/mass spectrometry as effective tool for trace analysis of organochlorine pesticide residues in honey samples. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2016. [DOI: 10.1007/s13738-016-0939-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
8
|
Mehdinia A, Einollahi S, Jabbari A. Magnetite nanoparticles surface-modified with a zinc(II)-carboxylate Schiff base ligand as a sorbent for solid-phase extraction of organochlorine pesticides from seawater. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1894-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
9
|
Trace analysis of multi-class pesticide residues in Chinese medicinal health wines using gas chromatography with electron capture detection. Sci Rep 2016; 6:21558. [PMID: 26883080 PMCID: PMC4756289 DOI: 10.1038/srep21558] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2015] [Accepted: 01/27/2016] [Indexed: 01/19/2023] Open
Abstract
A method is described for multi-residue, high-throughput determination of trace levels of 22 organochlorine pesticides (OCPs) and 5 pyrethroid pesticides (PYPs) in Chinese medicinal (CM) health wines using a QuEChERS (quick, easy, cheap, effective, rugged, and safe) based extraction method and gas chromatography-electron capture detection (GC-ECD). Several parameters were optimized to improve preparation and separation time while still maintaining high sensitivity. Validation tests of spiked samples showed good linearities for 27 pesticides (R = 0.9909-0.9996) over wide concentration ranges. Limits of detection (LODs) and quantification (LOQs) were measured at ng/L levels, 0.06-2 ng/L and 0.2-6 ng/L for OCPs and 0.02-3 ng/L and 0.06-7 ng/L for PYPs, respectively. Inter- and intra-day precision tests showed variations of 0.65-9.89% for OCPs and 0.98-13.99% for PYPs, respectively. Average recoveries were in the range of 47.74-120.31%, with relative standard deviations below 20%. The developed method was then applied to analyze 80 CM wine samples. Beta-BHC (Benzene hexachloride) was the most frequently detected pesticide at concentration levels of 5.67-31.55 mg/L, followed by delta-BHC, trans-chlordane, gamma-BHC, and alpha-BHC. The validated method is simple and economical, with adequate sensitivity for trace levels of multi-class pesticides. It could be adopted by laboratories for this and other types of complex matrices analysis.
Collapse
|
10
|
Li QL, Jing SJ, Zhang JF, Zhang L, Ran CC, Du CH, Jiang Y. Study of enrichment factors for six β-blockers in aliphatic alcohols by hollow-fiber liquid-phase microextraction. J Sep Sci 2015. [PMID: 26224511 DOI: 10.1002/jssc.201500487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The selectivity of a suitable organic solvent is key for extraction in liquid-phase microextraction experiments. Nevertheless, the screening process remains a daunting task. Our research aimed to study the relationship between extraction efficiency and extraction solvents, analytes, and finally select the appropriate extraction solvent. In the present article, β-blockers and six extraction solvents were chosen as the models and hollow-fiber liquid-phase microextraction was conducted. The relationship was built by statistical analysis on the data. Factors affecting extraction efficiency including the logarithms of the octanol/water partition coefficient (logPo/w ) of analytes, acid dissociation constants, the logarithms of the octanol/water partition coefficient of solvents and pH of the sample solution were investigated. The results showed that a low water solubility of extraction solvent is the foundation to ensure higher extraction efficiency. Moreover, when ΔlogPo/w > 0, a higher extraction efficiency is observed at lower ΔlogPo/w , on the contrary, when ΔlogPo/w < 0, extraction efficiency is higher as the absolute value of ΔlogPo/w becomes greater. Finally, the relationship between enrichment factor and extraction solvents, analytes was established and a helpful guidance was provided for the selection of an optimal solvent to obtain the best extraction efficiency by liquid-phase microextraction.
Collapse
Affiliation(s)
- Qing-Lian Li
- Department of Pharmaceutical Analysis, School of Pharmacy, Hebei Medical University, Shijiazhuang, Hebei Province, P. R. China
| | - Shao-Jun Jing
- Department of Pharmaceutical Analysis, School of Pharmacy, Hebei Medical University, Shijiazhuang, Hebei Province, P. R. China
| | - Jin-Feng Zhang
- Department of Pharmaceutical Analysis, School of Pharmacy, Hebei Medical University, Shijiazhuang, Hebei Province, P. R. China
| | - Lin Zhang
- Institute of Forensic Science of Supreme People's Procuratorate, Beijing, P.R. China
| | - Cong-Cong Ran
- Department of Pharmaceutical Analysis, School of Pharmacy, Hebei Medical University, Shijiazhuang, Hebei Province, P. R. China
| | - Chao-Hui Du
- Department of Pharmaceutical Analysis, School of Pharmacy, Hebei Medical University, Shijiazhuang, Hebei Province, P. R. China
| | - Ye Jiang
- Department of Pharmaceutical Analysis, School of Pharmacy, Hebei Medical University, Shijiazhuang, Hebei Province, P. R. China
| |
Collapse
|
11
|
Bagheri H, Banihashemi S. Sol–gel-based silver nanoparticles-doped silica – Polydiphenylamine nanocomposite for micro-solid-phase extraction. Anal Chim Acta 2015; 886:56-65. [DOI: 10.1016/j.aca.2015.06.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2015] [Revised: 06/01/2015] [Accepted: 06/02/2015] [Indexed: 10/23/2022]
|
12
|
Huang S, He S, Xu H, Wu P, Jiang R, Zhu F, Luan T, Ouyang G. Monitoring of persistent organic pollutants in seawater of the Pearl River Estuary with rapid on-site active SPME sampling technique. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2015; 200:149-158. [PMID: 25732847 DOI: 10.1016/j.envpol.2015.02.016] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Revised: 02/10/2015] [Accepted: 02/12/2015] [Indexed: 06/04/2023]
Abstract
An on-site active solid-phase microextraction (SPME) sampling technique coupled with gas chromatography-mass spectrometry (GC-MS) for sampling and monitoring 16 polycyclic aromatic hydrocarbons (PAHs) and 8 organochlorine pesticides (OCPs) in seawater was developed. Laboratory experiments demonstrated that the sampling-rate calibration method was practical and could be used for the quantification of on-site sampling. The proposed method was employed for field tests which covered large amounts of water samples in the Pearl River Estuary in rainy and dry seasons. The on-site SPME sampling method can avoid the contamination of sample, the losses of analytes during sample transportation, as well as the usage of solvent and time-consuming sample preparation process. Results indicated that the technique with the designed device can address the requirement of modern environment water analysis. In addition, the sources, bioaccumulation and potential risk to human of the PAHs and OCPs in seawater of the Pearl River Estuary were discussed.
Collapse
Affiliation(s)
- Siming Huang
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Shuming He
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Hao Xu
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Peiyan Wu
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Ruifen Jiang
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Fang Zhu
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Tiangang Luan
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China.
| | - Gangfeng Ouyang
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275, China.
| |
Collapse
|