1
|
Nahandast M, Darvishnejad F, Raoof JB, Ghani M. Modification of cellulose substrate by in situ synthesis of metal-organic framework-5 for thin film microextraction of some non-steroidal anti-inflammatory drugs and their measurement by high-performance liquid chromatography-ultraviolet detector. J Chromatogr A 2024; 1724:464924. [PMID: 38653038 DOI: 10.1016/j.chroma.2024.464924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 04/14/2024] [Accepted: 04/18/2024] [Indexed: 04/25/2024]
Abstract
This work, reports the successful preparation a thin film by a simple and inexpensive process for quantification of a model analytes in the urine sample using HPLC-UV. To this end, cellulose paper was employed as a substrate for the in-situ synthesis of MOF-5, to increase the resistance of the prepared film. The prepared film can be reused 26 times with no reduction in its performance. The thin film prepared by MOF-5 modified cellulose substrate was utilized in thin film microextraction (TFME) method for the extraction and preconcentration of naproxen, aspirin, tolmetin, and celecoxib. Under optimal conditions, the linear dynamic range of the target analytes was 2-500 µg L-1 with correlation coefficients (R2) ranging from 0.9961 to 0.9990. Also, the limits of detection (LODs), the limits of quantification (LOQs) and relative standard deviation (RSD%) of the proposed method for selected analytes ranged between 0.57 and 0.77 µg L-1, 1.7 to 2.3 and 3.5 % to 6.2 %, respectively. Moreover, relative recoveries varied from of 94 % to 108 %, indicating the absence of matrices effect in the proposed method. Eventually, the TFME was successfully used for the extraction of selected analytes from urine samples.
Collapse
Affiliation(s)
- Mahyar Nahandast
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Fatemeh Darvishnejad
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Jahan Bakhsh Raoof
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran.
| | - Milad Ghani
- Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| |
Collapse
|
2
|
Grover A, Mohiuddin I, Lee J, Brown RJC, Malik AK, Aulakh JS, Kim KH. Progress in pre-treatment and extraction of organic and inorganic pollutants by layered double hydroxide for trace-level analysis. ENVIRONMENTAL RESEARCH 2022; 214:114166. [PMID: 36027961 DOI: 10.1016/j.envres.2022.114166] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 08/17/2022] [Accepted: 08/18/2022] [Indexed: 06/15/2023]
Abstract
Continuous release of pollutants into the environment poses serious threats to environmental sustainability and human health. For trace-level analysis of pollutants, layered double hydroxide (LDH) is an attractive option to impart enhanced sorption capability and sensitivity toward pollutants because of its unique layered structure, tunable interior architecture, high anion-exchange capacities, and high porosity (e.g., Zn/Cr LDH/DABCO-IL, Ni/Al LDH, CS-Ni/Fe LDH, SDS-Fe3O4@SiO2@Mg-Al LDH, Boeh/Mg/Al LDH/pC, and Fe@NiAl LDH). In concert with the well-defined analytical methodologies (e.g., HPLC and GC), the LDH materials can be employed to detect trace-level targets (e.g., as low as ∼ 20 fg/L for phenols) in aqueous environments. This review highlights LDH as a promising material for pre-treatment of a variety of organic and inorganic target pollutants in complex real matrices. Challenges and future requirements for research into LDH-based analytical methods are also discussed.
Collapse
Affiliation(s)
- Aman Grover
- Department of Chemistry, Punjabi University, Patiala, 147002, Punjab, India
| | - Irshad Mohiuddin
- Department of Chemistry, Panjab University, Sector-14, Chandigarh, 160014, India
| | - Jechan Lee
- Department of Global Smart City & School of Civil, Architectural Engineering, and Landscape Architecture, Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Richard J C Brown
- Atmospheric Environmental Science Department, National Physical Laboratory, Teddington, TW11 0LW, United Kingdom
| | - Ashok Kumar Malik
- Department of Chemistry, Punjabi University, Patiala, 147002, Punjab, India.
| | | | - Ki-Hyun Kim
- Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-ro, Seoul, 04763, Republic of Korea.
| |
Collapse
|
3
|
Daryanavard SM, Zolfaghari H, Abdel-Rehim A, Abdel-Rehim M. Recent applications of microextraction sample preparation techniques in biological samples analysis. Biomed Chromatogr 2021; 35:e5105. [PMID: 33660303 DOI: 10.1002/bmc.5105] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 01/26/2021] [Accepted: 02/05/2021] [Indexed: 12/11/2022]
Abstract
Analysis of biological samples is affected by interfering substances with chemical properties similar to those of the target analytes, such as drugs. Biological samples such as whole blood, plasma, serum, urine and saliva must be properly processed for separation, purification, enrichment and chemical modification to meet the requirements of the analytical instruments. This causes the sample preparation stage to be of undeniable importance in the analysis of such samples through methods such as microextraction techniques. The scope of this review will cover a comprehensive summary of available literature data on microextraction techniques playing a key role for analytical purposes, methods of their implementation in common biological samples, and finally, the most recent examples of application of microextraction techniques in preconcentration of analytes from urine, blood and saliva samples. The objectives and merits of each microextration technique are carefully described in detail with respect to the nature of the biological samples. This review presents the most recent and innovative work published on microextraction application in common biological samples, mostly focused on original studies reported from 2017 to date. The main sections of this review comprise an introduction to the microextraction techniques supported by recent application studies involving quantitative and qualitative results and summaries of the most significant, recently published applications of microextracion methods in biological samples. This article considers recent applications of several microextraction techniques in the field of sample preparation for biological samples including urine, blood and saliva, with consideration for extraction techniques, sample preparation and instrumental detection systems.
Collapse
Affiliation(s)
| | - Hesane Zolfaghari
- Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, Iran
| | - Abbi Abdel-Rehim
- Department of Chemical Engineering and Biotechnology, Cambridge University, Cambridge, UK
| | - Mohamed Abdel-Rehim
- Functional Materials Division, Department of Applied Physics, School of Engineering Sciences, KTH Royal Institute of Technology, Stockholm, Sweden.,Department of Clinical Neuroscience, Centre for Psychiatry Research, Karolinska Institutet, Solna, Sweden
| |
Collapse
|
4
|
Ghani M, Raoof JB, Masoum S. In-situ formation of Zn-Al layered double oxides on electrochemically anodized nanoporous aluminum film as sorbent for chlorophenols extraction from water and wastewater followed by determination using HPLC. J Sep Sci 2021; 44:1264-1272. [PMID: 33400826 DOI: 10.1002/jssc.202000993] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2020] [Revised: 12/31/2020] [Accepted: 01/01/2021] [Indexed: 12/24/2022]
Abstract
Herein, we present a simple, cost-effective, and robust strategy for the in-situ preparation of Zn-Al layered double oxides-anodized aluminum thin film via a facile hydrothermal method, followed by calcination treatment of the Zn-Al layered double hydroxide in the air atmosphere. The in-situ prepared Zn-Al layered double oxide-anodized aluminum film was implemented as sorbent for thin film microextraction of four selected chlorophenols (4-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, and pentachlorophenol), followed by high-performance liquid chromatography-ultraviolet detection. The different variables of the thin film microextraction were screened via Plackett-Burman design and then optimized through Box-Behnken design. Under the optimum condition, the method showed good linear ranges (0.2-200 μg/L) with the coefficient of determinations higher than 0.9938. The calculated limit of detections were between 0.07 and 0.56 μg/L. Relative standard deviations of the method for determination of the analytes at 5 μg/L concentration level (n = 3) were ranged from 3.5 to 3.9% (as interday). The enrichment factors were between 39 and 58. This extraction method was demonstrated to be fast, efficient, and convenient. To study the capability of the developed method for real sample analysis, tap, well, river, and two types of wastewater samples were satisfactorily analyzed.
Collapse
Affiliation(s)
- Milad Ghani
- Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Jahan Bakhsh Raoof
- Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Saeed Masoum
- Department of Analytical Chemistry, Faculty of Chemistry, University of Kashan, Kashan, Iran
| |
Collapse
|
5
|
Darvishnejad F, Raoof JB, Ghani M. MIL-101 (Cr) @ graphene oxide-reinforced hollow fiber solid-phase microextraction coupled with high-performance liquid chromatography to determine diazinon and chlorpyrifos in tomato, cucumber and agricultural water. Anal Chim Acta 2020; 1140:99-110. [DOI: 10.1016/j.aca.2020.10.015] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Revised: 10/07/2020] [Accepted: 10/09/2020] [Indexed: 12/16/2022]
|
6
|
Jalili V, Barkhordari A, Ghiasvand A. Solid-phase microextraction technique for sampling and preconcentration of polycyclic aromatic hydrocarbons: A review. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104967] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
7
|
Alipour F, Raoof JB, Ghani M. Hierarchical zeolitic imidazolate framework-67 derived from in-situ synthesized CO-Al layered double hydroxide embedded within porous-anodized aluminum foil for thin film microextraction of caffeine followed by its high performance liquid chromatography-ultraviolet detection. J Chromatogr A 2020; 1626:461358. [PMID: 32797837 DOI: 10.1016/j.chroma.2020.461358] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2020] [Revised: 06/14/2020] [Accepted: 06/17/2020] [Indexed: 01/06/2023]
Abstract
In this study, the in-situ conversion of the synthesized Co-Al layered double hydroxide (Co-Al LDH) nanosheets to three dimensional hierarchical zeolitic imidazolate framework-67 (3D HZIF-67) was presented as a cost-effective, highly efficient, flexible and robust sorbent to carry out the microextraction process. In the first stage, the anodized aluminum foil was prepared electrochemically. Then, the Co-Al LDH precursor was constructed on the surface of the previously-prepared anodized Al foil applying in-situ formation approach. The procedure is followed by the conversion of the prepared Co-Al LDH film to 3D HZIF-67 film via a facile solvothermal method without adding cobalt salt. The in-situ prepared 3D HZIF-67-anodized Al was used for the thin film microextraction (TFME) of caffeine. The effective factors in TFME procedure were investigated and optimized through applying Central Composite Design (CCD). In the obtained optimal condition, the calibration curves for TFME-HPLC-UV of caffeine were linear in the range of 1-200 µg L-1 with the coefficient of determination (r2) higher than 0.9915. The limits of detection were 0.33 and 0.38 µg L-1, in water and urine matrices, respectively. Moreover, the enrichment factors (EFs) and absolute recoveries (%AR) were also calculated as 173-198 and 57.1%-65.3%, respectively. The inter-day relative standard deviations (RSDs) were evaluated as the method precision for 20 and 200 µg L-1 of spiked sample and were between 4.9-6.1%. The repeatability of the preparation step was investigated as batch-to-batch reproducibility and it was found to be 4.9%; as a result, the reproducibility of the presented film was approved. Finally, the proposed method was utilized to determine caffeine (as the model analyte) from different types of real samples including urine, coffee, beverage (Pepsi) and shampoo. The obtained recoveries (higher than 88%) confirmed the capability of the method for real sample analysis.
Collapse
Affiliation(s)
- Faezeh Alipour
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Jahan Bakhsh Raoof
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran.
| | - Milad Ghani
- Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| |
Collapse
|
8
|
Mirzaee MT, Seidi S, Razeghi Y, Manouchehri M, Shanehsaz M. In-tube stir bar sorptive extraction based on 3-aminopropyl triethoxysilane surface-modified Ce-doped ZnAl layered double hydroxide thin film for determination of nonsteroidal anti-inflammatory drugs in saliva samples. Mikrochim Acta 2020; 187:528. [PMID: 32860534 DOI: 10.1007/s00604-020-04489-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Accepted: 08/17/2020] [Indexed: 10/23/2022]
Abstract
A thin-film based on 3-aminopropyl triethoxysilane surface-modified Ce-doped zinc-aluminum layered double hydroxide was synthesized on the inner surface of an aluminum tube. It has been applied to in-tube stir bar sorptive extraction of nonsteroidal anti-inflammatory drugs in saliva samples followed by high-performance liquid chromatography. The sorbent was characterized by scanning electron microscopy, X-ray diffraction, Fourier-transform infrared spectroscopy, energy-dispersive X-ray spectroscopy, and elemental mapping. The extraction parameters including sample pH (4.2), extraction time (10 min), stirring speed (800 rpm), type of eluent (acidified tetrahydrofuran), eluent volume (100 μL), and desorption time (6 min) were thoroughly optimized. Under the optimum conditions, limits of detection were found to be less than 5.0 ng mL-1. Calibration plots were linear within the range 10-1000 ng mL-1 (R2 > 0.9982). Absolute recoveries were calculated in the range 63.5 to 72.4%. The repeatability (intra- and inter-day precision) and reproducibility (tube-to-tube precision) at concentrations of 50, 250, and 500 ng mL-1 were less than 7.6% and 9.4%, respectively. The method accuracy based on the relative error was calculated at these concentrations and ranged from - 4.9 to - 9.3% for intra-day relative error (%) and - 6.8 to - 11% for inter-day relative error (%). Finally, the method applicability was examined for the determination of nonsteroidal anti-inflammatory drugs in saliva samples, and good relative recoveries were obtained within the range 86.5 to 95.2%. As a result, the introduced method can be applied as a suitable alternative to measuring nonsteroidal anti-inflammatory drugs in biological fluids. Graphical abstract A surface-modified Ce-doped ZnAl LDH thin film was synthesized on the inner surface of an Al tube and applied for in-tube stir bar sorptive extraction of NSAIDs in saliva.
Collapse
Affiliation(s)
- Mahsa Torabi Mirzaee
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran, Iran
| | - Shahram Seidi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran, Iran.
| | - Yasaman Razeghi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran, Iran
| | - Mahshid Manouchehri
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran, Iran
| | - Maryam Shanehsaz
- Analytical Chemistry Research Laboratory, Mobin Shimi Azma Company, Tehran, Iran
| |
Collapse
|