1
|
Arunjaroensuk S, Yotpibulwong T, Fu PS, Wang JC, Hung CC, Mattheos N, Pimkhaokham A. Implant position accuracy using dynamic computer-assisted implant surgery (CAIS) combined with augmented reality: A randomized controlled clinical trial. J Dent Sci 2024; 19:S44-S50. [PMID: 39807435 PMCID: PMC11725068 DOI: 10.1016/j.jds.2024.09.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2024] [Revised: 09/13/2024] [Indexed: 01/16/2025] Open
Abstract
Background/purpose Computer-assisted implant surgery (CAIS) is increasingly performed to reduce deviations in implant position. Dynamic CAIS or navigation systems provide instant display of implant drilling instruments and patient positions directly on the computer monitor. Augmented reality (AR) technology allows operators to visualize real-time information projected onto the lenses of AR glasses. Although AR is being used in medical applications, there are few clinical studies on applying AR glasses to dental implants. The purpose of this randomized clinical study was to compare the accuracy of implant position using the dynamic CAIS with and without AR glasses. Materials and methods Twenty patients who needed a single dental implant were randomly divided into two groups: combined dynamic CAIS with AR glasses (AR glasses group, n = 10) and dynamic CAIS without AR glasses (non-AR glasses group, n = 10). Three-dimensional (3D) deviations of implant platform, apex and angular deviations were measured and analyzed using independent t-tests (P < 0.05). Results The 3D angular deviations in the AR glasses and non-AR glasses groups were 1.47 ± 1.01° and 2.42 ± 0.76°, respectively. Mean 3D entry point and apical deviations were 0.75 ± 0.45 mm and 0.87 ± 0.45 mm in the AR glasses group, whereas the non-AR glasses group were 1.11 ± 0.44 mm and 1.18 ± 0.50 mm, respectively. There was no statistically significant difference between the two groups. Conclusion Implant position accuracy using dynamic CAIS with AR glasses was similar to dynamic CAIS without AR glasses during a single implant placement.
Collapse
Affiliation(s)
- Sirida Arunjaroensuk
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
- Oral and Maxillofacial Surgery and Digital Implant Surgery Research Unit, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Thanida Yotpibulwong
- Oral and Maxillofacial Surgery and Digital Implant Surgery Research Unit, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Po-Sung Fu
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Clinical Dentistry, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Jen-Chyan Wang
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
- Division of Prosthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Chun-Cheng Hung
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
- Division of Prosthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Nikos Mattheos
- Oral and Maxillofacial Surgery and Digital Implant Surgery Research Unit, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
- Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden
| | - Atiphan Pimkhaokham
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
- Oral and Maxillofacial Surgery and Digital Implant Surgery Research Unit, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
2
|
Rutkunas V, Gendviliene I, Auskalnis L, Mangano F, Zlatev S, Ivanova V, Mijiritsky E, Borusevicius R. Influence of Kennedy class and number of implants on the accuracy of dynamic implant navigation: An in vitro study using an X-ray free evaluation methodology. J Dent 2023; 139:104679. [PMID: 37683800 DOI: 10.1016/j.jdent.2023.104679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 05/21/2023] [Accepted: 08/11/2023] [Indexed: 09/10/2023] Open
Abstract
OBJECTIVES The aim of this in vitro study was to evaluate the accuracy of fully guided dynamic implant navigation surgery in Kennedy I, II, and III class dental arch defects with two different implant designs, using an X-ray free evaluation method. METHODS Polyurethane resin maxillary models simulated posterior edentulous defects. Four cone beam computed tomography (CBCT) scans and four intraoral (IOS) scans were obtained for each model and a digital wax-up with the correct implant positions was made. The accuracy of implant positions was evaluated using an IOS-based X-ray-free method (3Shape). Four deviation characteristics were evaluated: insertion point, depth deviation, horizontal and angle deviation. RESULTS The insertion point deviation measures ranged from 0.19 mm to 1.71 mm. Depth (s) and (u) deviations ranged from -1.47 mm to 0.74 mm and from 0.02 mm to 1.47 mm, respectively. Horizontal deviation ranged from 0.09 mm to 1.37 mm. CONCLUSIONS There is a tendency of a decreasing insertion point deviation for an increasing number and distribution area of the teeth (increasing Kennedy class number). Kennedy class II and distal implant position had the most influence for the higher deviations. CLINICAL SIGNIFICANCE Dynamic implant guidance provides accurate spacing, angulation, depth and position of the implants. It is important to understand how the number of missing teeth and implant design could influence the accuracy of dynamic implant navigation. Thus, it is important to evaluate factors influencing the accuracy of dynamic systems by using a X-ray-free post-operative method and to overcome the limitations of providing multiple CBCT scans.
Collapse
Affiliation(s)
- Vygandas Rutkunas
- Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius 03101, Lithuania
| | - Ieva Gendviliene
- Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius 03101, Lithuania
| | - Liudas Auskalnis
- Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius 03101, Lithuania
| | - Francesco Mangano
- Honorary Professor in Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China
| | - Stefan Zlatev
- CAD/CAM Center of Dental Medicine at the Research Institute, Medical University-Plovdiv, Plovdiv 4000, Bulgaria
| | - Vasilena Ivanova
- Oral Surgery Department, Faculty of Dental Medicine, Medical University of Plovdiv, Plovdiv 4000, Bulgaria
| | - Eitan Mijiritsky
- Head and Neck Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, Department of Otolaryngology, Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv 699350, Israel
| | - Rokas Borusevicius
- Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius 03101, Lithuania.
| |
Collapse
|
3
|
Takács A, Hardi E, Cavalcante BGN, Szabó B, Kispélyi B, Joób-Fancsaly Á, Mikulás K, Varga G, Hegyi P, Kivovics M. Advancing accuracy in guided implant placement: A comprehensive meta-analysis: Meta-Analysis evaluation of the accuracy of available implant placement Methods. J Dent 2023; 139:104748. [PMID: 37863173 DOI: 10.1016/j.jdent.2023.104748] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 10/16/2023] [Accepted: 10/18/2023] [Indexed: 10/22/2023] Open
Abstract
OBJECTIVES This meta-analysis aimed to determine the accuracy of currently available computer-assisted implant surgery (CAIS) modalities under in vitro conditions and investigate whether these novel techniques can achieve clinically acceptable accuracy. DATA In vitro studies comparing the postoperative implant position with the preoperative plan were included. Risk of bias was assessed using the Quality Assessment Tool For In Vitro Studies (QUIN Tool) and a sensitivity analysis was conducted using funnel plots. SOURCES A systematic search was performed on April 18, 2023, using the following three databases: MEDLINE (via PubMed), EMBASE, and Cochrane Central Register of Controlled Trials. No filters or restrictions were applied during the search. RESULTS A total of 5,894 studies were included following study selection. Robotic- and static CAIS (sCAIS) had the most accurate and clinically acceptable outcomes. sCAIS was further divided according to the guidance level. Among the sCAIS groups, fully guided implant placement had the greatest accuracy. Augmented reality-based CAIS (AR-based CAIS) had clinically acceptable results for all the outcomes except for apical global deviation. Dynamic CAIS (dCAIS) demonstrated clinically safe results, except for horizontal apical deviation. Freehand implant placement was associated with the greatest number of errors. CONCLUSIONS Fully guided sCAIS demonstrated the most predictable outcomes, whereas freehand sCAIS demonstrated the lowest accuracy. AR-based and robotic CAIS may be promising alternatives. CLINICAL SIGNIFICANCE To our knowledge, this is the first meta-analysis to evaluate the accuracy of robotic CAIS and investigate the accuracy of various CAIS modalities.
Collapse
Affiliation(s)
- Anna Takács
- Department of Community Dentistry, Semmelweis University, Szentkirályi utca 40. 1088 Budapest, Hungary; Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary
| | - Eszter Hardi
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Department of Oro-Maxillofacial Surgery and Stomatology, Semmelweis University, Mária utca 52. 1085 Budapest, Hungary
| | - Bianca Golzio Navarro Cavalcante
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Department of Oral Biology, Semmelweis University, Nagyvárad tér 4. 1089 Budapest, Hungary
| | - Bence Szabó
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary
| | - Barbara Kispélyi
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Szentkirályi utca 47. 1088 Budapest, Hungary
| | - Árpád Joób-Fancsaly
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Department of Oro-Maxillofacial Surgery and Stomatology, Semmelweis University, Mária utca 52. 1085 Budapest, Hungary
| | - Krisztina Mikulás
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Szentkirályi utca 47. 1088 Budapest, Hungary
| | - Gábor Varga
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Department of Oral Biology, Semmelweis University, Nagyvárad tér 4. 1089 Budapest, Hungary
| | - Péter Hegyi
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Institute for Translational Medicine, Szentágothai Research Centre, Medical School, University of Pécs, Szigeti út 12. 7624 Pécs, Hungary; Division of Pancreatic Diseases, Heart and Vascular Center, Semmelweis University, Városmajor utca 68. 1122 Budapest, Hungary
| | - Márton Kivovics
- Department of Community Dentistry, Semmelweis University, Szentkirályi utca 40. 1088 Budapest, Hungary; Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary.
| |
Collapse
|
4
|
Feng Y, Yao Y, Yang X. Effect of a dynamic navigation device on the accuracy of implant placement in the completely edentulous mandible: An in vitro study. J Prosthet Dent 2023; 130:731-737. [PMID: 35000696 DOI: 10.1016/j.prosdent.2021.12.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 11/30/2021] [Accepted: 12/01/2021] [Indexed: 02/08/2023]
Abstract
STATEMENT OF PROBLEM A less invasive and more convenient workflow is needed for dynamic navigation-guided implant surgery for the edentulous arch. PURPOSE The purpose of this in vitro study was to evaluate the accuracy of a novel dynamic navigation device developed for the completely edentulous mandible. MATERIAL AND METHODS Two temporary 1-piece mini-implants were placed in the anterior region of a completely edentulous mandibular model for fixation of the navigation device. A total of 40 implants were inserted in 10 completely edentulous mandibular models with the aid of the dynamic navigation device. The accuracy of placement was determined by overlapping the preoperative plan with the postoperative cone beam computed tomography (CBCT) scans. The difference in the accuracy at different implant positions was compared by MANOVA and Bonferroni-corrected ANOVAs. The difference in accuracy between implants #1-20 and #21-40 was assessed for learning progression. RESULTS The deviation of the implants (mean ±standard deviation) was 1.14 ±0.50 mm at the entry point and 1.29 ±0.48 mm at the apex. The mean ±standard deviation angular deviation was 3.02 ±1.32 degrees. No significant difference was seen between the planned and the placed deviation among the 4 implant positions. After repeated placement with this dynamic approach, implant accuracy at the entry (P=.001) and apex (P=.017) improved significantly. CONCLUSIONS The navigation device achieved acceptable implant placement accuracy in the edentulous mandible. Deviations between the planned and placed locations were not affected by different implant positions. After repeated operations with this dynamic approach, accuracy at the entry and apex improved significantly.
Collapse
Affiliation(s)
- Yuzhang Feng
- Graduate student, Graduate Prosthodontics, State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan Province, PR China
| | - Yufei Yao
- Predoctoral student, State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan Province, PR China
| | - Xingmei Yang
- Associate Professor, State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan Province, PR China.
| |
Collapse
|
5
|
Linn TY, Salamanca E, Aung LM, Huang TK, Wu YF, Chang WJ. Accuracy of implant site preparation in robotic navigated dental implant surgery. Clin Implant Dent Relat Res 2023; 25:881-891. [PMID: 37199055 DOI: 10.1111/cid.13224] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 05/05/2023] [Accepted: 05/09/2023] [Indexed: 05/19/2023]
Abstract
BACKGROUND Modern technological advancements have led to increase in the development of surgical robots in dentistry, resulting in excellent clinical treatment outcomes. PURPOSE This study aimed to determine the accuracy of automatic robotic implant site preparation for different implant sizes by correlating planned and posttreatment positions, and to compare the performance of robotic and human freehand drilling. METHOD Seventy-six drilling sites on partially edentulous models were used, with three different implant sizes (Ø = 3.5 × 10 mm, 4.0 × 10 mm, 5.0 × 10 mm). The robotic procedure was performed using software for calibration and step-by-step drilling processes. After robotic drilling, deviations in the implant position from the planned position were determined. The angulation, depth, and coronal and apical diameters on the sagittal plane of sockets created by human and robotic drilling were measured. RESULTS The deviation of the robotic system was 3.78° ± 1.97° (angulation), 0.58 ± 0.36 mm (entry point), and 0.99 ± 0.56 mm (apical point). Comparison of implant groups showed the largest deviation from the planned position for 5 mm implants. On the sagittal plane, there were no significant differences between robotic and human surgery except for the 5-mm implant angulation, indicating similar quality between human and robotic drilling. Based on standard implant measurements, robotic drilling exhibited comparable performance to freehand human drilling. CONCLUSIONS A robotic surgical system can provide the greatest accuracy and reliability regarding the preoperative plan for small implant diameters. In addition, the accuracy of robotic drilling for anterior implant surgery can also be comparable to that of human drilling.
Collapse
Affiliation(s)
- Thu Ya Linn
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Eisner Salamanca
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Lwin Moe Aung
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Ta-Ko Huang
- School of Dentistry, Kaohsiung Medical University, Kaohsiung, Taiwan
- EPED Incorporation, Kaohsiung, Taiwan
| | - Yi-Fan Wu
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Wei-Jen Chang
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
- Dental Department, Shuang-Ho Hospital, Taipei Medical University, New Taipei City, Taiwan
| |
Collapse
|
6
|
Marques-Guasch J, Bofarull-Ballús A, Giralt-Hernando M, Hernández-Alfaro F, Gargallo-Albiol J. Dynamic Implant Surgery-An Accurate Alternative to Stereolithographic Guides-Systematic Review and Meta-Analysis. Dent J (Basel) 2023; 11:150. [PMID: 37366673 DOI: 10.3390/dj11060150] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 04/26/2023] [Accepted: 05/25/2023] [Indexed: 06/28/2023] Open
Abstract
(1) Background: Dynamic guided surgery is a computer-guided freehand technology that allows highly accurate procedures to be carried out in real time through motion-tracking instruments. The aim of this research was to compare the accuracy between dynamic guided surgery (DGS) and alternative implant guidance methods, namely, static guided surgery (SGS) and freehand (FH). (2) Methods: Searches were conducted in the Cochrane and Medline databases to identify randomized controlled clinical trials (RCTs) and prospective and retrospective case series and to answer the following focused question: "What implant guidance tool is more accurate and secure with regard to implant placement surgery?" The implant deviation coefficient was calculated for four different parameters: coronal and apical horizontal, angular, and vertical deviations. Statistical significance was set at a p-value of 0.05 following application of the eligibility criteria. (3) Results: Twenty-five publications were included in this systematic review. The results show a non-significant weighted mean difference (WMD) between the DGS and the SGS in all of the assessed parameters: coronal (n = 4 WMD = 0.02 mm; p = 0.903), angular (n = 4 WMD = -0.62°; p = 0.085), and apical (n = 3 WMD = 0.08 mm; p = 0.401). In terms of vertical deviation, not enough data were available for a meta-analysis. However, no significant differences were found among the techniques (p = 0.820). The WMD between DGS and FH demonstrated significant differences favoring DGS in three parameters as follows: coronal (n = 3 WMD = -0.66 mm; p =< 0.001), angular (n = 3 WMD = -3.52°; p < 0.001), and apical (n = 2 WMD = -0.73 mm; p =< 0.001). No WMD was observed regarding the vertical deviation analysis, but significant differences were seen among the different techniques (p = 0.038). (4) Conclusions: DGS is a valid alternative treatment achieving similar accuracy to SGS. DGS is also more accurate, secure, and precise than the FH method when transferring the presurgical virtual implant plan to the patient.
Collapse
Affiliation(s)
- Jordi Marques-Guasch
- Department of Oral and Maxillofacial Surgery, Universitat Internacional de Catalunya, Josep Trueta s/n, Sant Cugat del Vallès, 08195 Barcelona, Spain
| | - Anna Bofarull-Ballús
- Department of Oral and Maxillofacial Surgery, Universitat Internacional de Catalunya, Josep Trueta s/n, Sant Cugat del Vallès, 08195 Barcelona, Spain
| | - Maria Giralt-Hernando
- Department of Oral and Maxillofacial Surgery, Universitat Internacional de Catalunya, Josep Trueta s/n, Sant Cugat del Vallès, 08195 Barcelona, Spain
| | - Federico Hernández-Alfaro
- Department of Oral and Maxillofacial Surgery, Universitat Internacional de Catalunya, Josep Trueta s/n, Sant Cugat del Vallès, 08195 Barcelona, Spain
| | - Jordi Gargallo-Albiol
- Department of Oral and Maxillofacial Surgery, Universitat Internacional de Catalunya, Josep Trueta s/n, Sant Cugat del Vallès, 08195 Barcelona, Spain
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI 48109, USA
| |
Collapse
|
7
|
Otaghsara SST, Joda T, Thieringer FM. Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: An in vitro study: Accuracy of static vs. dynamic CAIS. J Dent 2023; 132:104487. [PMID: 36948382 DOI: 10.1016/j.jdent.2023.104487] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 03/06/2023] [Accepted: 03/19/2023] [Indexed: 03/24/2023] Open
Abstract
OBJECTIVES This in-vitro study compared the accuracy of implant placement using static versus dynamic computer-assisted implant surgery (CAIS) at two implant sites. METHODS Partially edentulous maxillary models were 3D-printed, and two implants (Straumann TL RN4.1 × 10mm) were inserted in FDI positions 15 and 16 per model using two CAIS approaches (10 models per approach). A three-dimensional (3D) reconstruction tool was used for implant planning, surgical guide design, and measuring implant positioning accuracy. In static CAIS, the implants were placed with 3D-printed surgical guides (n=20); in dynamic CAIS, real-time navigation was performed (n=20). Primary outcomes were defined as coronal and apical global deviation as well as angular deviations and deviation comparison between implants placed at positions 15 and 16; the secondary outcome was the bi-directional deviation in mesial-distal, buccal-palatal, and apical-coronal direction. RESULTS The mean±SD 3D-deviation at implant platform and apex levels for static CAIS in position 15 was 0.81±0.31mm, 1.41±0.37mm, and in position 16 was 0.67±0.31mm, 1.07±0.32mm. PRIMARY OUTCOMES buccal-palatal deviation is higher using static CAIS, and mesial-distal deviation is higher in dynamic CAIS. In position 15, mesial-distal deviation at the apex and the platform were lower in static approaches than in dynamic ones. In implant position 16, buccal-palatal deviation at the apex was lower in the dynamic group than with static ones. SECONDARY OUTCOMES for bi-directional analysis, buccal-palatal deviation at the platform (P=0.0028) and mesial-distal deviation at the apex (P=0.0056) were significantly lower in molar sites using static CAIS. Mesial-distal deviation at the apex (P=0.0246) revealed significantly lower values in position 16 following dynamic CAIS. CONCLUSIONS Both static and dynamic CAIS resulted in accurate implant placement. However, dynamic CAIS exhibited higher deviation in the mesial direction in an in-vitro setting. In addition, the implant site affects the accuracy of both CAIS approaches. CLINICAL SIGNIFICANCE Static CAIS demonstrates the highest accuracy for guided implant placement today.
Collapse
Affiliation(s)
- Seyedeh Sahar Taheri Otaghsara
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland; Department of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, Basel, Switzerland; Department of Reconstructive Dentistry, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland
| | - Tim Joda
- Department of Reconstructive Dentistry, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland; Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Florian Markus Thieringer
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland; Department of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, Basel, Switzerland.
| |
Collapse
|
8
|
Novel and accurate 3D-Printed surgical guide for mandibular reconstruction with integrated dental implants. Comput Biol Med 2022; 151:106327. [PMID: 36442275 DOI: 10.1016/j.compbiomed.2022.106327] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 10/25/2022] [Accepted: 11/14/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE Patients with mandibular defects due to trauma or infiltrated disease are in a need of functional mandibular implants that will completely restore the function of their lower jaw. One of the most important roles of well-functioning jaw is mastication, a complex mechanism. A conventional approach used in oral and maxillofacial surgery accomplish this aim via two major surgeries- mandibular reconstruction and surgical placement of dental implants. Little work has been done on combining the two surgeries into with using Additive Manufacturing (AM) and digital planning. MATERIAL AND METHODS This case study offers a mandibular implant design solution with pre-positioned dental implants that can reduce the requirement to only one surgery. Mandibular implant was designed using 3-Matic software (Materialise, Belgium). Positions for dental implants were restoratively-driven and planned on the designed mandibular implant in Blue Sky Plan 4 software (Blue Sky Bio, USA) and placed prior to mandibular reconstruction using a 3D-printed surgical guide. Finite Element Analysis (FEA) was used to evaluate the mechanical behaviour of the 3D-printed surgical guide during dental implant placement. RESULTS The surgical guide was fabricated using SLA and stress distribution was evaluated in ANSYS Workbench FEM software (Ansys Inc Swanson, Houston, USA). Results showed that the designed surgical guide can withstand the forces occurring during the surgery. CONCLUSION The proposed method substantially reduces the surgical procedure and recovery time, increases the accuracy, and allows for a predictable restorative solution that can be visualised from the beginning.
Collapse
|
9
|
Postl L, Mücke T, Hunger S, Wuersching SN, Holberg S, Bissinger O, Burgkart R, Malek M, Krennmair S. Biopsies of osseous jaw lesions using 3D-printed surgical guides: a clinical study. Eur J Med Res 2022; 27:104. [PMID: 35780184 PMCID: PMC9250179 DOI: 10.1186/s40001-022-00726-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Accepted: 06/13/2022] [Indexed: 11/23/2022] Open
Abstract
Background Bone biopsies are often necessary to make a diagnosis in the case of irregular bone structures of the jaw. A 3D-printed surgical guide may be a helpful tool for enhancing the accuracy of the biopsy and for ensuring that the tissue of interest is precisely removed for examination. This study was conducted to compare the accuracy of biopsies performed with 3D-printed surgical guides to that of free-handed biopsies. Methods Computed tomography scans were performed on patients with bony lesions of the lower jaw. Surgical guides were planned via computer-aided design and manufactured by a 3D-printer. Biopsies were performed with the surgical guides. Bone models of the lower jaw with geometries identical to the patients’ lower jaws were produced using a 3D-printer. The jaw models were fitted into a phantom head model and free-handed biopsies were taken as controls. The accuracy of the biopsies was evaluated by comparing the parameters for the axis, angle and depth of the biopsies to the planned parameters. Results Eight patients were included. The mean deviation between the biopsy axes was significantly lower in guided procedures than in free-handed biopsies (1.4 mm ± 0.9 mm; 3.6 mm ± 1.0 mm; p = 0.0005). The mean biopsy angle deviation was also significantly lower in guided biopsies than in free-handed biopsies (6.8° ± 4.0; 15.4° ± 3.6; p = 0.0005). The biopsy depth showed no significant difference between the guided and the free-handed biopsies. Conclusions Computer-guided biopsies allow significantly higher accuracy than free-handed procedures.
Collapse
Affiliation(s)
- Lukas Postl
- Medical Faculty, Johannes Kepler University Linz, Altenberger Strasse 69, 4040, Linz, Austria. .,NumBioLab, Ludwig-Maximilians University of Munich, Munich, Germany.
| | - Thomas Mücke
- Department of Oral and Maxillo-Facial Surgery, Klinikum Rechts Der Isar, Technische Universitaet Muenchen, Munich, Germany
| | - Stefan Hunger
- Medical Faculty, Johannes Kepler University Linz, Altenberger Strasse 69, 4040, Linz, Austria
| | - Sabina Noreen Wuersching
- Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Munich, Germany
| | - Svenia Holberg
- NumBioLab, Ludwig-Maximilians University of Munich, Munich, Germany
| | - Oliver Bissinger
- Department of Oral and Maxillofacial Surgery, Medizinische Universitaet Innsbruck, Innsbruck, Austria
| | - Rainer Burgkart
- Clinic of Orthopaedics and Sportorthopaedics, Klinikum Rechts Der Isar, Technische Universitaet Muenchen, Munich, Germany
| | - Michael Malek
- Clinic of Oral and Maxillofacial Surgery, Kepler University Hospital, Johannes Kepler University, Linz, Austria
| | - Stefan Krennmair
- Medical Faculty, Johannes Kepler University Linz, Altenberger Strasse 69, 4040, Linz, Austria.,NumBioLab, Ludwig-Maximilians University of Munich, Munich, Germany
| |
Collapse
|
10
|
Eftekhar Ashtiani R, Ghasemi Z, Nami M, Mighani F, Namdari M. Accuracy of static digital surgical guides for dental implants based on the guide system: A systematic review. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2021; 122:600-607. [PMID: 33161170 DOI: 10.1016/j.jormas.2020.10.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Revised: 10/23/2020] [Accepted: 10/26/2020] [Indexed: 06/11/2023]
Abstract
In the present study, we tried to review the current literature, focusing on the effect of different guide systems on the accuracy of the digital surgical guides. A search in PubMed's database, without any date restriction, was performed using keywords based on the PICO question. 54 of the 2378 articles' were chosen for full-text assessment. Articles were screened using predetermined inclusion and exclusion criteria. 21 articles were included in the qualitative assessment. Descriptive analysis was performed for numeric parameters using mean ± standard deviation. Six types of guide systems were used in the included articles. The commonest guide system was SimPlant (45.64%) followed by NobleGuide (23.00%). The pooled mean angle deviation, global coronal deviation, and global apical deviation were 3.43 mm (95% CI = 2.96, 3.90), 1.16 mm (95% CI = 0.98, 1.24) and 1.35 mm (95% CI = 1.11, 1.59), respectively. The maximum mean(SD) of angle deviation, global coronal deviation, and global apical deviation happened in Stent Cad 4.1(1.86) degrees, NobleGuide 1.86(0.56) mm, and OnDemend3d 1.56(1.48) mm, respectively. Although a final statement could not be made on which system is better, it is certain that the software affects the deviation and could be as important as the implant itself. CLINICAL SIGNIFICANCE: The choice of guide systems used for the production of static guide systems which was studied in this article could affect the accuracy of the implant placement procedure.
Collapse
Affiliation(s)
- R Eftekhar Ashtiani
- Department of Dental Technology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Z Ghasemi
- School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| | - M Nami
- School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - F Mighani
- School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - M Namdari
- Community Oral Health Department, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran; Department of Biostatistics, School of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
11
|
Edelmann C, Wetzel M, Knipper A, Luthardt RG, Schnutenhaus S. Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial. J Clin Med 2021; 10:jcm10091808. [PMID: 33919257 PMCID: PMC8122675 DOI: 10.3390/jcm10091808] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 04/20/2021] [Accepted: 04/20/2021] [Indexed: 02/06/2023] Open
Abstract
Background: This prospective clinical study aimed to investigate a possible deviation between the digitally planned implant position and the position achieved using dynamic navigation. The aim of the study was to establish clinical effectiveness and precision of implantation using dynamic navigation. Methods: Twenty consecutive patients received an implant (iSy-Implantat, Camlog, Wimsheim, Germany). One screw implant was placed in one jaw with remaining dentition of at least six teeth. The workflow was fully digital. Digital implant planning was conducted using cone-beam computed tomography (CBCT) and an intraoral scan of the actual condition. Twenty implants were subsequently placed using a dynamic computer-assisted procedure. The clinical situation of the implant position was recorded using an intraoral scan. Using these data, models were produced via 3D printing, and CBCTs of these models were made using laboratory analogs. Deviations of the achieved implant position from the planned position were determined using evaluation software. Results: The evaluation of 20 implants resulted in a mean angle deviation of 2.7° (95% CI 2.2–3.3°). The 3D deviation at the implant shoulder was 1.83 mm (95% CI 1.34–2.33 mm). No significant differences were found for any of the parameters between the implantation in the upper or lower jaw and an open or flapless procedure (p-value < 0.05). Conclusion: The clinical trial showed that sufficiently precise implantation was possible with the dynamic navigation system used here. Dynamic navigation can improve the quality of implant positioning. In particular, the procedure allows safe positioning of the implants in minimally invasive procedures, which usually cannot be performed freehand in this form. A clinical benefit and effectiveness can be determined from the results.
Collapse
Affiliation(s)
- Cornelia Edelmann
- Centre for Dentistry, Dr Schnutenhaus Community Health Centre (CHC) GmbH, 78247 Hilzingen, Germany; (C.E.); (M.W.); (A.K.)
| | - Martin Wetzel
- Centre for Dentistry, Dr Schnutenhaus Community Health Centre (CHC) GmbH, 78247 Hilzingen, Germany; (C.E.); (M.W.); (A.K.)
| | - Anne Knipper
- Centre for Dentistry, Dr Schnutenhaus Community Health Centre (CHC) GmbH, 78247 Hilzingen, Germany; (C.E.); (M.W.); (A.K.)
| | - Ralph G. Luthardt
- Department of Dentistry, Clinic for Prosthodontics, Ulm University, 89081 Ulm, Germany;
| | - Sigmar Schnutenhaus
- Centre for Dentistry, Dr Schnutenhaus Community Health Centre (CHC) GmbH, 78247 Hilzingen, Germany; (C.E.); (M.W.); (A.K.)
- Department of Dentistry, Clinic for Prosthodontics, Ulm University, 89081 Ulm, Germany;
- Correspondence:
| |
Collapse
|
12
|
Schnutenhaus S, Knipper A, Wetzel M, Edelmann C, Luthardt R. Accuracy of Computer-Assisted Dynamic Navigation as a Function of Different Intraoral Reference Systems: An In Vitro Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18063244. [PMID: 33801039 PMCID: PMC8003934 DOI: 10.3390/ijerph18063244] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Revised: 03/12/2021] [Accepted: 03/18/2021] [Indexed: 11/16/2022]
Abstract
The aim of this in vitro study was to determine whether the process chain influences the accuracy of a computer-assisted dynamic navigation procedure. Four different data integration workflows using cone-beam computed tomography (CBCT), conventional impressions, and intraoral digitization with and without reference markers were analyzed. Digital implant planning was conducted using data from the CBCT scans and 3D data of the oral models. The restoration of the free end of the lower jaw was simulated. Fifteen models were each implanted with two new teeth for each process chain. The models were then scanned with scan bodies screwed onto the implants. The deviations between the planned and achieved implant positions were determined. The evaluation of all 120 implants resulted in a mean angular deviation of 2.88 ± 2.03°. The mean 3D deviation at the implant shoulder was 1.53 ± 0.70 mm. No significant differences were found between the implant regions. In contrast, the workflow showed significant differences in various parameters. The position of the reference marker affected the accuracy of the implant position. The in vitro examination showed that precise implantation is possible with the dynamic navigation system used in this study. The results are of the same order of magnitude that can be achieved using static navigation methods. Clinical studies are yet to confirm the results of this study.
Collapse
Affiliation(s)
- Sigmar Schnutenhaus
- Centre for Dentistry, Dr Schnutenhaus Community Health Centre (CHC) GmbH, 78247 Hilzingen, Germany; (A.K.); (M.W.); (C.E.)
- Department for Dentistry, Clinic for Prosthodontics, Ulm University, 89081 Ulm, Germany;
- Correspondence:
| | - Anne Knipper
- Centre for Dentistry, Dr Schnutenhaus Community Health Centre (CHC) GmbH, 78247 Hilzingen, Germany; (A.K.); (M.W.); (C.E.)
| | - Martin Wetzel
- Centre for Dentistry, Dr Schnutenhaus Community Health Centre (CHC) GmbH, 78247 Hilzingen, Germany; (A.K.); (M.W.); (C.E.)
| | - Cornelia Edelmann
- Centre for Dentistry, Dr Schnutenhaus Community Health Centre (CHC) GmbH, 78247 Hilzingen, Germany; (A.K.); (M.W.); (C.E.)
| | - Ralph Luthardt
- Department for Dentistry, Clinic for Prosthodontics, Ulm University, 89081 Ulm, Germany;
| |
Collapse
|
13
|
Postl L, Mücke T, Hunger S, Bissinger O, Malek M, Holberg S, Burgkart R, Krennmair S. In-house 3D-printed surgical guides for osseous lesions of the lower jaw: an experimental study. Eur J Med Res 2021; 26:25. [PMID: 33722284 PMCID: PMC7958719 DOI: 10.1186/s40001-021-00495-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Accepted: 03/02/2021] [Indexed: 11/30/2022] Open
Abstract
Background The accuracy of computer-assisted biopsies at the lower jaw was compared to the accuracy of freehand biopsies. Methods Patients with a bony lesion of the lower jaw with an indication for biopsy were prospectively enrolled. Two customized bone models per patient were produced using a 3D printer. The models of the lower jaw were fitted into a phantom head model to simulate operation room conditions. Biopsies for the study group were taken by means of surgical guides and freehand biopsies were performed for the control group. Results The deviation of the biopsy axes from the planning was significantly less when using templates. It turned out to be 1.3 ± 0.6 mm for the biopsies with a surgical guide and 3.9 ± 1.1 mm for the freehand biopsies. Conclusions Surgical guides allow significantly higher accuracy of biopsies. The preliminary results are promising, but clinical evaluation is necessary.
Collapse
Affiliation(s)
- Lukas Postl
- Department of Oral and Maxillofacial Surgery, Kepler University Hospital GmbH, Johannes Kepler University Linz, Krankenhausstr. 9, 4021, Linz, Austria. .,NumBioLab, Ludwig-Maximilians University of Munich, Munich, Germany. .,Department of Oral and Maxillo-Facial Surgery, Klinikum rechts der Isar, Technische Universitaet Muenchen, Munich, Germany.
| | - Thomas Mücke
- Department of Oral and Maxillo-Facial Surgery, Klinikum rechts der Isar, Technische Universitaet Muenchen, Munich, Germany
| | - Stefan Hunger
- Department of Oral and Maxillofacial Surgery, Kepler University Hospital GmbH, Johannes Kepler University Linz, Krankenhausstr. 9, 4021, Linz, Austria
| | - Oliver Bissinger
- Department of Oral and Maxillofacial Surgery, Medizinische Universitaet Innsbruck, Innsbruck, Austria
| | - Michael Malek
- Department of Oral and Maxillofacial Surgery, Kepler University Hospital GmbH, Johannes Kepler University Linz, Krankenhausstr. 9, 4021, Linz, Austria
| | - Svenia Holberg
- NumBioLab, Ludwig-Maximilians University of Munich, Munich, Germany
| | - Rainer Burgkart
- Department of Orthopaedics and Sports Orthopedics, Klinikum rechts der Isar, Technische Universitaet Muenchen, Munich, Germany
| | - Stefan Krennmair
- Department of Oral and Maxillofacial Surgery, Kepler University Hospital GmbH, Johannes Kepler University Linz, Krankenhausstr. 9, 4021, Linz, Austria.,NumBioLab, Ludwig-Maximilians University of Munich, Munich, Germany
| |
Collapse
|
14
|
Jorba-García A, González-Barnadas A, Camps-Font O, Figueiredo R, Valmaseda-Castellón E. Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis. Clin Oral Investig 2021; 25:2479-2494. [PMID: 33635397 DOI: 10.1007/s00784-021-03833-8] [Citation(s) in RCA: 99] [Impact Index Per Article: 24.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Accepted: 02/05/2021] [Indexed: 12/18/2022]
Abstract
OBJECTIVES To assess the accuracy of dynamic computer-aided implant surgery (dCAIS) systems when used to place dental implants and to compare its accuracy with static computer-aided implant surgery (sCAIS) systems and freehand implant placement. MATERIALS AND METHODS An electronic search was made to identify all relevant studies reporting on the accuracy of dCAIS systems for dental implant placement. The following PICO question was developed: "In patients or artificial models, is dental implant placement accuracy higher when dCAIS systems are used in comparison with sCAIS systems or with freehand placement? The main outcome variable was angular deviation between the central axes of the planned and final position of the implant. The data were extracted in descriptive tables, and a meta-analysis of single means was performed in order to estimate the deviations for each variable using a random-effects model. RESULTS Out of 904 potential articles, the 24 selected assessed 9 different dynamic navigation systems. The mean angular and entry 3D global deviations for clinical studies were 3.68° (95% CI: 3.61 to 3.74; I2 = 99.4%) and 1.03 mm (95% CI: 1.01 to 1.04; I2 = 82.4%), respectively. Lower deviation values were reported in in vitro studies (mean angular deviation of 2.01° (95% CI: 1.95 to 2.07; I2 = 99.1%) and mean entry 3D global deviation of 0.46 mm (95% CI: 0.44 to 0.48 ; I2 = 98.5%). No significant differences were found between the different dCAIS systems. These systems were significantly more accurate than sCAIS systems (mean difference (MD): -0.86°; 95% CI: -1.35 to -0.36) and freehand implant placement (MD: -4.33°; 95% CI: -5.40 to -3.25). CONCLUSION dCAIS systems allow highly accurate implant placement with a mean angular of less than 4°. However, a 2-mm safety margin should be applied, since deviations of more than 1 mm were observed. dCAIS systems increase the implant placement accuracy when compared with freehand implant placement and also seem to slightly decrease the angular deviation in comparison with sCAIS systems. CLINICAL RELEVANCE The use of dCAIS could reduce the rate of complications since it allows a highly accurate implant placement.
Collapse
Affiliation(s)
- Adrià Jorba-García
- Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
| | - Albert González-Barnadas
- Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain.,IDIBELL Institute, Barcelona, Spain
| | - Octavi Camps-Font
- Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain.,IDIBELL Institute, Barcelona, Spain
| | - Rui Figueiredo
- Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain. .,IDIBELL Institute, Barcelona, Spain. .,Facultat de Medicina i Ciències de la Salut, Campus de Bellvitge, Universitat de Barcelona (UB), Pavelló de Govern, 2a Planta, Despatx 2.9, C/Feixa Llarga s/n, E-08907 L'Hospitalet de Llobregat, Barcelona, Spain.
| | - Eduard Valmaseda-Castellón
- Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain.,IDIBELL Institute, Barcelona, Spain
| |
Collapse
|
15
|
Accuracy of Dynamic Computer-Assisted Implant Placement: A Systematic Review and Meta-Analysis of Clinical and In Vitro Studies. J Clin Med 2021; 10:jcm10040704. [PMID: 33670136 PMCID: PMC7916851 DOI: 10.3390/jcm10040704] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 02/07/2021] [Accepted: 02/08/2021] [Indexed: 12/26/2022] Open
Abstract
The aim of this systematic review and meta-analysis is to analyze the accuracy of implant placement using computer-assisted dynamic navigation procedures. An electronic literature search was carried out, supplemented by a manual search. The literature search was completed in June 2020. The results of in vitro and clinical studies were recorded separately from each other. For inclusion in the review, the studies had to examine at least the prosthetically relevant parameters for angle deviation, as well as global deviation or lateral deviation at the platform of the implant. Sixteen of 320 articles were included in the investigation: nine in vitro and seven clinical studies. The meta-analysis showed values of 4.1° for the clinical studies (95% CI, 3.12-5.10) and 3.7° for the in vitro studies (95% CI, 2.31-5.10) in terms of the angle deviation. The global deviation at the implant apex of the implant was 1.00 mm for the clinical studies (95% CI, 0.83-1.16) and 0.91 mm for the in vitro studies (95% CI, 0.60-1.12). These values indicate no significant difference between the clinical and in vitro studies. The results of this systematic review show a clinical accuracy of dynamic computer-assisted navigation that is comparable to that of static navigation. However, the dynamic navigation systems show a great heterogeneity that must be taken into account. Moreover, currently there are few clinical data available. Therefore, further investigations into the practicability of dynamic navigation seem necessary.
Collapse
|
16
|
Pellegrino G, Ferri A, Cercenelli L, Marcelli E, Marchetti C, Tarsitano A, Ciocca L. 3D planning of ear prosthesis and navigated flapless surgery for craniofacial implants: A pilot study. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2020; 122:391-396. [PMID: 32977038 DOI: 10.1016/j.jormas.2020.09.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 09/13/2020] [Accepted: 09/16/2020] [Indexed: 10/23/2022]
Abstract
New 3D digital technologies can be applied to implant-supported ear prostheses to restore anatomical structures damaged by cancer, dysplasia, or trauma. However, several factors influence the accuracy of implant positioning using a cranial template. This pilot study describes an innovative navigated flapless surgery for craniofacial implants, prosthetically guided by 3D planning of the ear prosthesis. Laser surface scanning of the face allowed for mapping of the healthy ear onto the defect site, and projection of the volume and position of the final prosthesis. The projected ear volume was superimposed on the skull bone image obtained by cone-beam computed tomography (CBCT), performed with the navigation system marker plate positioned in the patient's mouth. The craniofacial implants were fitted optimally to the ear prosthesis. After system calibration, real-time navigated implant placement based on the virtual planning was performed with minimally invasive flapless surgery under local anesthesia. After 3 months of healing, digital impressions of the implants were made, and the digital manufacturing workflow was completed to manufacture the ear prosthesis anchored to the craniofacial implants. The proposed digital method facilitated implant positioning during flapless surgery, improving the ear prosthesis manufacturing process and reducing operation time, patient morbidity, and related costs. This protocol avoids the need for a reference tool fixed in the cranial bone, as is usually required for maxillofacial surgery, and confirmed that surgical navigation is useful for guiding the insertion of craniofacial implants during flapless surgery.
Collapse
Affiliation(s)
- G Pellegrino
- Department of Biomedical and Neuromotor Science, Alma Mater Studiorum University of Bologna, Via S. Vitale 59, 40125 Bologna, Italy.
| | - A Ferri
- Department of Biomedical and Neuromotor Science, Alma Mater Studiorum University of Bologna, Via S. Vitale 59, 40125 Bologna, Italy.
| | - L Cercenelli
- Department of Experimental Diagnostic and Specialty Medicine - Department of Biomedical and Neuromotor Science, Alma Mater Studiorum University of Bologna, Via Massarenti 9, 40138 Bologna, Italy.
| | - E Marcelli
- Department of Experimental Diagnostic and Specialty Medicine, Alma Mater Studiorum University of Bologna, Via Massarenti 9, 40138 Bologna, Italy.
| | - C Marchetti
- Department of Biomedical and Neuromotor Science, Alma Mater Studiorum University of Bologna, Via Massarenti 9, 40138 Bologna, Italy.
| | - A Tarsitano
- Department of Biomedical and Neuromotor Science, Alma Mater Studiorum University of Bologna, Via Massarenti 9, 40138 Bologna, Italy.
| | - L Ciocca
- Department of Biomedical and Neuromotor Science, Alma Mater Studiorum University of Bologna, Via S. Vitale 59, 40125 Bologna, Italy.
| |
Collapse
|
17
|
Pellegrino G, Bellini P, Cavallini PF, Ferri A, Zacchino A, Taraschi V, Marchetti C, Consolo U. Dynamic Navigation in Dental Implantology: The Influence of Surgical Experience on Implant Placement Accuracy and Operating Time. An in Vitro Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17062153. [PMID: 32213873 PMCID: PMC7142455 DOI: 10.3390/ijerph17062153] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Revised: 03/21/2020] [Accepted: 03/22/2020] [Indexed: 11/16/2022]
Abstract
AIM the aim of this in vitro study was to test whether the implant placement accuracy and the operating time can be influenced by the operator's experience. MATERIALS AND METHODS sixteen models underwent a (Cone Beam Computer Tomography) CBCT and implant positioning was digitally planned on this. The models were randomly assigned to four operators with different levels of surgical experience. One hundred and twelve implant sites were drilled using a dynamic navigation system and operating times were measured. Based on postoperative CBCTs, dental implants were virtually inserted and superimposed over the planned ones. Two-dimensional and 3D deviations between planned and virtually inserted implants were measured at the entry point and at the apical point. Angular and vertical errors were also calculated. RESULTS considering coronal and apical 3D deviations, no statistically significant differences were found between the four operators (p = 0.27; p = 0.06). Some vectorial components of the deviation at the apical point and the angular errors of some operators differed from each other. CONCLUSIONS within the limitations of this study, dynamic navigation can be considered a reliable technique both for experienced and novice clinicians.
Collapse
Affiliation(s)
- Gerardo Pellegrino
- Oral and Maxillofacial Surgery Division, DIBINEM, University of Bologna, 40125 Bologna, Italy; (G.P.); (A.F.); (A.Z.); (V.T.); (C.M.)
| | - Pierantonio Bellini
- Division of Oral and Maxillofacial Surgery, Dental Clinic, University of Modena and Reggio Emilia, 41125 Modena, Italy; (P.B.); (P.F.C.)
| | - Pier Francesco Cavallini
- Division of Oral and Maxillofacial Surgery, Dental Clinic, University of Modena and Reggio Emilia, 41125 Modena, Italy; (P.B.); (P.F.C.)
| | - Agnese Ferri
- Oral and Maxillofacial Surgery Division, DIBINEM, University of Bologna, 40125 Bologna, Italy; (G.P.); (A.F.); (A.Z.); (V.T.); (C.M.)
| | - Andrea Zacchino
- Oral and Maxillofacial Surgery Division, DIBINEM, University of Bologna, 40125 Bologna, Italy; (G.P.); (A.F.); (A.Z.); (V.T.); (C.M.)
| | - Valerio Taraschi
- Oral and Maxillofacial Surgery Division, DIBINEM, University of Bologna, 40125 Bologna, Italy; (G.P.); (A.F.); (A.Z.); (V.T.); (C.M.)
| | - Claudio Marchetti
- Oral and Maxillofacial Surgery Division, DIBINEM, University of Bologna, 40125 Bologna, Italy; (G.P.); (A.F.); (A.Z.); (V.T.); (C.M.)
| | - Ugo Consolo
- Division of Oral and Maxillofacial Surgery, Dental Clinic, University of Modena and Reggio Emilia, 41125 Modena, Italy; (P.B.); (P.F.C.)
- Correspondence: ; Tel.: +39-059-422-49-12
| |
Collapse
|
18
|
Sigcho López DA, Pintaudi Amorim K, Laganá DC. Auxiliary Reflectance Sensor for Guided Surgery with Dental Implants: In Vitro Study. Eur J Dent 2020; 14:115-122. [PMID: 32168539 PMCID: PMC7069737 DOI: 10.1055/s-0040-1705074] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Objectives
The aim of this research was to develop a sensor of approximation by reflectance for guided surgery with dental implants without flap detachment, and verify the effectiveness of this system.
Materials and Methods
Ten models of total edentulous arches were divided into two groups. Two implants of 3.5 × 11.5 mm (NeoDent) were inserted in each model; in Group 1 (G1), a stereolithographic guide
NeoGuide
system was used. In Group 2 (G2), the experimental approximation sensor was used for the insertion of the implants. The evaluation of the results was performed by overlapping the virtual planning images with the tomographies of the models of the implants inserted.
Results
There were no statistically significant differences between the guide and the sensor groups. The averages and standard deviations observed at the angulation of the guide was 4.15 (2.65 degrees) and 5.48 (2.85 degrees) at the sensor. The linear deviations at the cervical level were 0.002 (1.37) and 0.11 (1.47) mm and at the apical level 0.19 (1.28) and 0.21 (1.42) mm, respectively.
Conclusions
The use of a guide is important for the stabilization of the drills; the greatest challenge is to control the apical position of the implants, especially in highly reabsorbed edges. The experimental sensor can become an auxiliary tool to the stereolithographic guides; however, several difficulties must still be overcome to recommend the use of a sensor.
Collapse
|
19
|
Pellegrino G, Mangano C, Mangano R, Ferri A, Taraschi V, Marchetti C. Augmented reality for dental implantology: a pilot clinical report of two cases. BMC Oral Health 2019; 19:158. [PMID: 31324246 PMCID: PMC6642526 DOI: 10.1186/s12903-019-0853-y] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Accepted: 07/11/2019] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Despite the limited number of articles dedicated to its use, augmented reality (AR) is an emerging technology that has shown to have increasing applications in multiple different medical sectors. These include, but are not limited to, the Maxillo-facial and Dentistry disciplines of medicine. In these medical specialties, the focus of AR technology is to achieve a more visible surgical field during an operation. Currently, this goal is brought about by an accurate display of either static or dynamic diagnostic images via the use of a visor or specific glasses. The objective of this study is to evaluate the feasibility of using a virtual display for dynamic navigation via AR. The secondary outcome is to evaluate if the use of this technology could affect the accuracy of dynamic navigation. CASE PRESENTATION Two patients, both needing implant rehabilitation in the upper premolar area, were treated with flapless surgery. Prior to the procedure itself, the position of the implant was virtually planned and placed for each of the patients using their previous scans. This placement preparation contributed to a dynamic navigation system that was displayed on AR glasses. This, in turn, allowed for the use of a computer-aided/image-guided procedure to occur. Dedicated software for surface superimposition was then used to match the planned position of the implant and the real one obtained from the postoperative scan. Accuracies, using this procedure were evaluated by way of measuring the deviation between real and planned positions of the implants. For both surgeries it was possible to proceed using the AR technology as planned. The deviations for the first implant were 0.53 mm at the entry point and 0.50 mm at the apical point and for the second implant were 0.46 mm at the entry point and 0.48 mm at the apical point. The angular deviations were respectively 3.05° and 2.19°. CONCLUSIONS From the results of this pilot study, it seems that AR can be useful in dental implantology for displaying dynamic navigation systems. While this technology did not seem to noticeably affect the accuracy of the procedure, specific software applications should further optimize the results.
Collapse
Affiliation(s)
- Gerardo Pellegrino
- Oral and Maxillofacial Surgery Unit, DIBINEM, University of Bologna, 125, Via San Vitale 59, 40125, Bologna, Italy.
| | - Carlo Mangano
- Digital Dentistry Section, University San Raffaele, Milan, Italy
| | | | - Agnese Ferri
- Oral and Maxillofacial Surgery Unit, DIBINEM, University of Bologna, 125, Via San Vitale 59, 40125, Bologna, Italy
| | - Valerio Taraschi
- University of Technology - Sydney, School of Life Sciences, Sydney, Australia
| | - Claudio Marchetti
- Chief of Oral and Maxillofacial Surgery Unit, DIBINEM, University of Bologna, Bologna, Italy
| |
Collapse
|
20
|
Comrie ML, Monteith G, Zur Linden A, Oblak M, Phillips J, James FMK, on behalf of the Ontario Veterinary College Rapid Prototyping of Patient-specific Implants for Dogs (RaPPID) group. The accuracy of computed tomography scans for rapid prototyping of canine skulls. PLoS One 2019; 14:e0214123. [PMID: 30908536 PMCID: PMC6433237 DOI: 10.1371/journal.pone.0214123] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Accepted: 03/08/2019] [Indexed: 12/27/2022] Open
Abstract
This study’s objective was to determine the accuracy of using current computed tomography (CT) scan and software techniques for rapid prototyping by quantifying the margin of error between CT models and laser scans of canine skull specimens. Twenty canine skulls of varying morphology were selected from an anatomy collection at a veterinary school. CT scans (bone and standard algorithms) were performed for each skull, and data segmented (testing two lower threshold settings of 226HU and -650HU) into 3-D CT models. Laser scans were then performed on each skull. The CT models were compared to the corresponding laser scan to determine the error generated from the different types of CT model parameters. This error was then compared between the different types of CT models to determine the most accurate parameters. The mean errors for the 226HU CT models, both bone and standard algorithms, were not significant from zero error (p = 0.1076 and p = 0.0580, respectively). The mean errors for both -650HU CT models were significant from zero error (p < 0.001). Significant differences were detected between CT models for 3 CT model comparisons: Bone (p < 0.0001); Standard (p < 0.0001); and -650HU (p < 0.0001). For 226HU CT models, a significant difference was not detected between CT models (p = 0.2268). Independent of the parameters tested, the 3-D models derived from CT imaging accurately represent the real skull dimensions, with CT models differing less than 0.42 mm from the real skull dimensions. The 226HU threshold was more accurate than the -650HU threshold. For the 226HU CT models, accuracy was not dependent on the CT algorithm. For the -650 CT models, bone was more accurate than standard algorithms. Knowing the inherent error of this procedure is important for use in 3-D printing for surgical planning and medical education.
Collapse
Affiliation(s)
- Michaela L. Comrie
- Department Human Health and Nutritional Science, College of Biological Science, University of Guelph, Guelph, Ontario, Canada
- Department of Biomedical Sciences, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada
| | - Gabrielle Monteith
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada
| | - Alex Zur Linden
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada
| | - Michelle Oblak
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada
| | - John Phillips
- Centre for Advanced Manufacturing and Design Technologies, Sheridan College, Brampton, Ontario, Canada
| | - Fiona M. K. James
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada
- * E-mail:
| | | |
Collapse
|
21
|
Ma L, Jiang W, Zhang B, Qu X, Ning G, Zhang X, Liao H. Augmented reality surgical navigation with accurate CBCT-patient registration for dental implant placement. Med Biol Eng Comput 2018; 57:47-57. [DOI: 10.1007/s11517-018-1861-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Accepted: 06/10/2018] [Indexed: 10/28/2022]
|
22
|
Huang TK, Yang CH, Hsieh YH, Wang JC, Hung CC. Augmented reality (AR) and virtual reality (VR) applied in dentistry. Kaohsiung J Med Sci 2018; 34:243-248. [DOI: 10.1016/j.kjms.2018.01.009] [Citation(s) in RCA: 94] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 12/20/2017] [Accepted: 01/12/2018] [Indexed: 11/25/2022] Open
|
23
|
Zhou W, Liu Z, Song L, Kuo CL, Shafer DM. Clinical Factors Affecting the Accuracy of Guided Implant Surgery—A Systematic Review and Meta-analysis. J Evid Based Dent Pract 2018; 18:28-40. [DOI: 10.1016/j.jebdp.2017.07.007] [Citation(s) in RCA: 102] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2017] [Accepted: 07/17/2017] [Indexed: 12/22/2022]
|
24
|
Ali MJ, Naik MN, Girish CM, Ali MH, Kaliki S, Dave TV, Dendukuri G. Interactive navigation-guided ophthalmic plastic surgery: assessment of optical versus electromagnetic modes and role of dynamic reference frame location using navigation-enabled human skulls. Clin Ophthalmol 2016; 10:2383-2390. [PMID: 27932861 PMCID: PMC5135409 DOI: 10.2147/opth.s118079] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
AIM The aim of this study was to assess the anatomical accuracy of navigation technology in localizing defined anatomic landmarks within the orbit with respect to type of technology (optical versus electromagnetic systems) and position of the dynamic reference marker on the skull (vertex, temporal, parietal, and mastoid) using in vitro navigation-enabled human skulls. The role of this model as a possible learning tool for anatomicoradiological correlations was also assessed. METHODS Computed tomography (CT) scans were performed on three cadaveric human skulls using the standard image-guidance acquisition protocols. Thirty-five anatomical landmarks were identified for stereotactic navigation using the image-guided StealthStation S7™ in both electromagnetic and optical modes. Three outcome measures studied were accuracy of anatomical localization and its repeatability, comparisons between the electromagnetic and optical modes in assessing radiological accuracy, and the efficacy of dynamic reference frame (DRF) at different locations on the skull. RESULTS The geometric localization of all the identified anatomical landmarks could be achieved accurately. The Cohen's kappa agreements between the surgeons were found to be perfect (kappa =0.941) at all predetermined points. There was no difference in anatomical localization between the optical and electromagnetic modes (P≤0.001). Precision for radiological identification did not differ with various positions of the DRF. Skulls with intact anatomical details and careful CT image acquisitions were found to be stereotactically useful. CONCLUSION Accuracy of anatomic localization within the orbit with navigation technology is equal with optical and electromagnetic system. The location of DRF does not affect the accuracy. Navigation-enabled skull models can be potentially useful as teaching tools for achieving the accurate radiological orientation of orbital and periorbital structures.
Collapse
Affiliation(s)
| | | | | | - Mohammad Hasnat Ali
- The Operation Eyesight Universal Institute for Eye Cancer, L.V. Prasad Eye Institute, Hyderabad, India
| | - Swathi Kaliki
- The Operation Eyesight Universal Institute for Eye Cancer, L.V. Prasad Eye Institute, Hyderabad, India
| | | | | |
Collapse
|
25
|
Tack P, Victor J, Gemmel P, Annemans L. 3D-printing techniques in a medical setting: a systematic literature review. Biomed Eng Online 2016; 15:115. [PMID: 27769304 PMCID: PMC5073919 DOI: 10.1186/s12938-016-0236-4] [Citation(s) in RCA: 595] [Impact Index Per Article: 66.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Accepted: 10/09/2016] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Three-dimensional (3D) printing has numerous applications and has gained much interest in the medical world. The constantly improving quality of 3D-printing applications has contributed to their increased use on patients. This paper summarizes the literature on surgical 3D-printing applications used on patients, with a focus on reported clinical and economic outcomes. METHODS Three major literature databases were screened for case series (more than three cases described in the same study) and trials of surgical applications of 3D printing in humans. RESULTS 227 surgical papers were analyzed and summarized using an evidence table. The papers described the use of 3D printing for surgical guides, anatomical models, and custom implants. 3D printing is used in multiple surgical domains, such as orthopedics, maxillofacial surgery, cranial surgery, and spinal surgery. In general, the advantages of 3D-printed parts are said to include reduced surgical time, improved medical outcome, and decreased radiation exposure. The costs of printing and additional scans generally increase the overall cost of the procedure. CONCLUSION 3D printing is well integrated in surgical practice and research. Applications vary from anatomical models mainly intended for surgical planning to surgical guides and implants. Our research suggests that there are several advantages to 3D-printed applications, but that further research is needed to determine whether the increased intervention costs can be balanced with the observable advantages of this new technology. There is a need for a formal cost-effectiveness analysis.
Collapse
Affiliation(s)
- Philip Tack
- Department of Public Health, Ghent University, De Pintelaan 185, 9000, Ghent, Belgium.
| | - Jan Victor
- Ghent University Hospital, Ghent University, De Pintelaan 185, 9000, Ghent, Belgium
| | - Paul Gemmel
- Departement of Economics & Business Administration, Ghent University, Tweekerkenstraat 2, 9000, Ghent, Belgium
| | - Lieven Annemans
- Department of Public Health, Ghent University, De Pintelaan 185, 9000, Ghent, Belgium
| |
Collapse
|
26
|
Karami D, Alborzinia HR, Amid R, Kadkhodazadeh M, Yousefi N, Badakhshan S. In-Office Guided Implant Placement for Prosthetically Driven Implant Surgery. Craniomaxillofac Trauma Reconstr 2016; 10:246-254. [PMID: 28751952 DOI: 10.1055/s-0036-1584891] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2015] [Accepted: 03/06/2016] [Indexed: 10/21/2022] Open
Abstract
Application of surgical stents for implant placement via guided flapless surgery is increasing. However, high cost, need for some professional machines, and not taking into account the soft-tissue parameters have limited their application. We sought to design and introduce a technique named in-office guided implant placement (iGIP) to decrease the cost by using available devices in office and enhance the applicability of surgical stents. A customized surgical stent was fabricated based on prosthetic, soft- and hard-tissue parameters by taking into account the amount of available bone (using the computed tomographic [CT] data), soft-tissue thickness and contour (using a composite-covered radiographic stent), and position of the final crown (by diagnostic cast wax up and marking the final crown position with composite). The efficacy of iGIP, in terms of the accuracy of the three-dimensional position of the implant placed in the study cast and in patient's mouth, was confirmed by direct observation and postoperative CT. The iGIP can enhance implant placement in the prosthetically desired position in various types of edentulism. Using this technique minimizes the risk of unwanted consequences, as the soft-tissue thickness and contour are taken into account when fabricating a surgical stent.
Collapse
Affiliation(s)
| | | | - Reza Amid
- Dental Research Center, Shahid Beheshti University of Medical Science, Evin, Tehran, Iran
| | - Mahdi Kadkhodazadeh
- Dental Research Center, Shahid Beheshti University of Medical Science, Evin, Tehran, Iran
| | | | | |
Collapse
|
27
|
Vehmeijer M, van Eijnatten M, Liberton N, Wolff J. A Novel Method of Orbital Floor Reconstruction Using Virtual Planning, 3-Dimensional Printing, and Autologous Bone. J Oral Maxillofac Surg 2016; 74:1608-12. [PMID: 27137437 DOI: 10.1016/j.joms.2016.03.044] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2016] [Revised: 03/27/2016] [Accepted: 03/31/2016] [Indexed: 11/25/2022]
Abstract
Fractures of the orbital floor are often a result of traffic accidents or interpersonal violence. To date, numerous materials and methods have been used to reconstruct the orbital floor. However, simple and cost-effective 3-dimensional (3D) printing technologies for the treatment of orbital floor fractures are still sought. This study describes a simple, precise, cost-effective method of treating orbital fractures using 3D printing technologies in combination with autologous bone. Enophthalmos and diplopia developed in a 64-year-old female patient with an orbital floor fracture. A virtual 3D model of the fracture site was generated from computed tomography images of the patient. The fracture was virtually closed using spline interpolation. Furthermore, a virtual individualized mold of the defect site was created, which was manufactured using an inkjet printer. The tangible mold was subsequently used during surgery to sculpture an individualized autologous orbital floor implant. Virtual reconstruction of the orbital floor and the resulting mold enhanced the overall accuracy and efficiency of the surgical procedure. The sculptured autologous orbital floor implant showed an excellent fit in vivo. The combination of virtual planning and 3D printing offers an accurate and cost-effective treatment method for orbital floor fractures.
Collapse
Affiliation(s)
- Maarten Vehmeijer
- Maxillofacial Surgeon, Department of Oral and Maxillofacial Surgery/Oral Pathology, VU University Medical Center, Amsterdam, The Netherlands
| | - Maureen van Eijnatten
- PhD Student, Department of Oral and Maxillofacial Surgery/Oral Pathology and 3D Innovation Lab, VU University Medical Center, Amsterdam, The Netherlands.
| | - Niels Liberton
- Senior Development Engineer, Department of Physics and Medical Technology and 3D Innovation Lab, VU University Medical Center, Amsterdam, The Netherlands
| | - Jan Wolff
- Assistant Professor and Head of 3D Innovation Lab, Department of Oral and Maxillofacial Surgery/Oral Pathology and 3D Innovation Lab, VU University Medical Center, Amsterdam, The Netherlands
| |
Collapse
|
28
|
Lin HH, Lo LJ. Three-dimensional computer-assisted surgical simulation and intraoperative navigation in orthognathic surgery: a literature review. J Formos Med Assoc 2015; 114:300-7. [PMID: 25744942 DOI: 10.1016/j.jfma.2015.01.017] [Citation(s) in RCA: 82] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2014] [Revised: 01/26/2015] [Accepted: 01/31/2015] [Indexed: 10/23/2022] Open
Abstract
By incorporating three-dimensional (3D) imaging and computer-aided design and manufacturing techniques, 3D computer-assisted technology has been applied widely to provide accurate guidance for assessment and treatment planning in clinical practice. This technology has recently been used in orthognathic surgery to improve surgical planning and outcome. The modality will gradually become popular. This study reviewed the literature concerning the use of computer-assisted techniques in orthognathic surgery including surgical planning, simulation, intraoperative translation of the virtual surgery, and postoperative evaluation. A Medline, PubMed, ProQuest, and ScienceDirect search was performed to find relevant articles with regard to 3D computer-assisted orthognathic surgery in the past 10 years. A total of 460 articles were revealed, out of which 174 were publications addressed the topic of this study. The purpose of this article is to present an overview of the state-of-art methods for 3D computer-assisted technology in orthognathic surgery. From the review we can conclude that the use of computer-assisted technique in orthognathic surgery provides the benefit of optimal functional and aesthetic results, patient satisfaction, precise translation of the treatment plan, and facilitating intraoperative manipulation.
Collapse
Affiliation(s)
- Hsiu-Hsia Lin
- Craniofacial Research Center, Chang Gung Memorial Hospital, Chang Gung University, Taoyuan, Taiwan
| | - Lun-Jou Lo
- Plastic and Reconstructive Surgery, and Craniofacial Research Center, Chang Gung Memorial Hospital, Chang Gung University, Taoyuan, Taiwan.
| |
Collapse
|