1
|
Rodríguez-Galet A, Ventosa-Cubillo J, Bendomo V, Eyene M, Mikue-Owono T, Nzang J, Ncogo P, Benito A, Holguín Á. HIV diagnosis in Equatorial Guinea. Keys to reduce the diagnostic and therapeutic delay. J Infect Public Health 2024; 17:102476. [PMID: 38901117 DOI: 10.1016/j.jiph.2024.102476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 06/03/2024] [Accepted: 06/06/2024] [Indexed: 06/22/2024] Open
Abstract
BACKGROUND In Equatorial Guinea, only 54 % of people living with HIV know their HIV status. There are no confirmatory or molecular diagnostic techniques for early diagnosis or monitoring of infection in the country. Rapid diagnostic tests can induce false-positive diagnoses if used as a confirmatory technique. Our study aimed to identify the challenges of early HIV diagnosis in Equatorial Guinea by analyzing the rate of false positive diagnoses, diagnostic and therapeutic delays, and treatment failures among those on antiretroviral therapy. METHODS From 2019-2022, dried blood from 341 children, adolescents and adults diagnosed in Equatorial Guinea as HIV-positive by rapid diagnostic testing, and from 54 HIV-exposed infants were collected in Bata and sent to Madrid to confirm HIV-infection by molecular (Xpert HIV-1Qual, Cepheid) and/or serological confirmatory assays (Geenius-HIV-1/2, BioRad). HIV diagnostic delay (CD4 <350cells/mm3), advanced disease at diagnosis (CD4 <200cells/mm3) and antiretroviral treatment delay and failure (viraemia >1,000RNA-HIV-1-copies/ml) were also studied after viral quantification (XpertVL HIV-1, Cepheid). RESULTS False-positive diagnoses were identified in 5 % of analysed samples. HIV infection was confirmed in 90.5 % of previously diagnosed patients in Equatorial Guinea and 3.7 % of HIV-exposed children undiagnosed in the field. Two-thirds of each new HIV patient had delayed diagnosis, and one-third had advanced disease. Treatment delay occurred in 28.3 % of patients, being around four times more likely in adolescents/adults than children. More than half (56 %) of 232 treated patients presented treatment failure, being significantly higher in children/adolescents than in adults (82.9 %/90 % vs. 45.6 %, p < 0.001). CONCLUSION We identified some challenges of early HIV diagnosis in Equatorial Guinea, revealing a high rate of false positive diagnoses, diagnostic/treatment delays, and treatment failures that need to be addressed. The implementation of more accurate rapid diagnostic techniques and confirmatory tests, along with improving access to care, treatment, awareness, and screening, would contribute to controlling the spread of HIV in the country.
Collapse
Affiliation(s)
- Ana Rodríguez-Galet
- Laboratorio de Epidemiología Molecular del VIH-1, Departamento de Microbiología, Hospital Universitario Ramón y Cajal-Instituto Ramón y Cajal de Investigación Sanitaria (IRYCIS) y RITIP-CoRISpe, 28034, Madrid, Spain.
| | | | - Verónica Bendomo
- Unidad de Referencia de Enfermedades Infecciosas (UREI), Hospital Regional de Bata, Bata 88240, Equatorial Guinea.
| | - Manuel Eyene
- Unidad de Referencia de Enfermedades Infecciosas (UREI), Hospital Regional de Bata, Bata 88240, Equatorial Guinea.
| | - Teresa Mikue-Owono
- Laboratorio de Análisis Clínicos, Hospital Regional de Bata, Bata 88240, Equatorial Guinea.
| | - Jesús Nzang
- Fundación Estatal Salud, Infancia y Bienestar Social (CSAI), 28029 Madrid, Spain.
| | - Policarpo Ncogo
- Fundación Estatal Salud, Infancia y Bienestar Social (CSAI), 28029 Madrid, Spain.
| | - Agustín Benito
- Centro Nacional de Medicina Tropical (CNMT), Instituto de Salud Carlos III (ISCIII), 28029 Madrid, Spain; Centro de Investigación Biomédica en Red en Enfermedades Infecciosas (CIBERINFECT), 28029 Madrid, Spain.
| | - África Holguín
- Laboratorio de Epidemiología Molecular del VIH-1, Departamento de Microbiología, Hospital Universitario Ramón y Cajal-Instituto Ramón y Cajal de Investigación Sanitaria (IRYCIS) y RITIP-CoRISpe, 28034, Madrid, Spain; Centro de Investigación Biomédica en Red en Epidemiologia y Salud Pública (CIBERESP), 28029 Madrid, Spain.
| |
Collapse
|
2
|
Rodríguez-Galet A, Ventosa-Cubillo J, Bendomo V, Eyene M, Mikue-Owono T, Nzang J, Ncogo P, Gonzalez-Alba JM, Benito A, Holguín Á. High Drug Resistance Levels Compromise the Control of HIV Infection in Pediatric and Adult Populations in Bata, Equatorial Guinea. Viruses 2022; 15:27. [PMID: 36680067 PMCID: PMC9864178 DOI: 10.3390/v15010027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 12/09/2022] [Accepted: 12/13/2022] [Indexed: 12/24/2022] Open
Abstract
A lack of HIV viral load (VL) and HIV drug resistance (HIVDR) monitoring in sub-Saharan Africa has led to an uncontrolled circulation of HIV-strains with drug resistance mutations (DRM), compromising antiretroviral therapy (ART). This study updates HIVDR data and HIV-1 variants in Equatorial Guinea (EG), providing the first data on children/adolescents in the country. From 2019−2020, 269 dried blood samples (DBS) were collected in Bata Regional Hospital (EG) from 187 adults (73 ART-naïve/114 ART-treated) and 82 children/adolescents (25 HIV-exposed-ART-naïve/57 ART-treated). HIV-1 infection was confirmed in Madrid by molecular/serological confirmatory tests and ART-failure by VL quantification. HIV-1 pol region was identified as transmitted/acquired DRM, predicted antiretroviral susceptibility (Stanfordv9.0) and HIV-1 variants (phylogeny). HIV infection was confirmed in 88.1% of the individuals and virological failure (VL > 1000 HIV-1-RNA copies/mL) in 84.2/88.9/61.9% of 169 ART-treated children/adolescents/adults. Among the 167 subjects with available data, 24.6% suffered a diagnostic delay. All 125 treated had experienced nucleoside retrotranscriptase inhibitors (NRTI); 95.2% were non-NRTI (NNRTI); 22.4% had experienced integrase inhibitors (INSTI); and 16% had experienced protease inhibitors (PI). At sampling, they had received 1 (37.6%), 2 (32%), 3 (24.8%) or 4 (5.6%) different ART-regimens. Among the 43 treated children−adolescents/37 adults with sequence, 62.8/64.9% carried viruses with major-DRM. Most harbored DRM to NNRTI (68.4/66.7%), NRTI (55.3/43.3%) or NRTI+NNRTI (50/33.3%). One adult and one child carried major-DRM to PI and none carried major-DRM to INSTI. Most participants were susceptible to INI and PI. DRM was absent in 36.2% of treated patients with VL > 1000 cp/mL, suggesting adherence failure. TDR prevalence in 59 ART-naïve adults was high (20.3%). One-half (53.9%) of the 141 subjects with pol sequence carried CRF02_AG. The observed high rate of ART-failure and transmitted/acquired HIVDR could compromise the 95-95-95-UNAIDS targets in EG. Routine VL and resistance monitoring implementation are mandatory for early detection of ART-failure and optimal rescue therapy selection ART regimens based on PI, and INSTI can improve HIV control in EG.
Collapse
Affiliation(s)
- Ana Rodríguez-Galet
- HIV-1 Molecular Epidemiology Laboratory, Microbiology and Parasitology Department, Hospital Ramón y Cajal-IRYCIS and CIBEREsp-RITIP-CoRISpe, 20834 Madrid, Spain
| | - Judit Ventosa-Cubillo
- HIV-1 Molecular Epidemiology Laboratory, Microbiology and Parasitology Department, Hospital Ramón y Cajal-IRYCIS and CIBEREsp-RITIP-CoRISpe, 20834 Madrid, Spain
- Fundación Estatal, Salud, Infancia y Bienestar Social (CSAI), 28029 Madrid, Spain
| | - Verónica Bendomo
- Unidad de Referencia de Enfermedades Infecciosas (UREI), Hospital Regional de Bata, Bata 88240, Equatorial Guinea
| | - Manuel Eyene
- Unidad de Referencia de Enfermedades Infecciosas (UREI), Hospital Regional de Bata, Bata 88240, Equatorial Guinea
| | - Teresa Mikue-Owono
- Laboratorio de Análisis Clínicos, Hospital Regional de Bata, Bata 88240, Equatorial Guinea
| | - Jesús Nzang
- Fundación Estatal, Salud, Infancia y Bienestar Social (CSAI), 28029 Madrid, Spain
| | - Policarpo Ncogo
- Fundación Estatal, Salud, Infancia y Bienestar Social (CSAI), 28029 Madrid, Spain
| | - José María Gonzalez-Alba
- Grupo de Investigación en Microbiología Translacional, Instituto de Investigación Sanitaria del Principado de Asturias (ISPA), Microbiology Department, Hospital Universitario Central de Asturias (HUCA), 33011 Oviedo, Spain
| | - Agustín Benito
- Centro Nacional de Medicina Tropical (CNMT), Instituto de Salud Carlos III (ISCIII), 28029 Madrid, Spain
- Centro de Investigación Biomédica en Red en Enfermedades Infecciosas (CIBERINFEC), 28029 Madrid, Spain
| | - África Holguín
- HIV-1 Molecular Epidemiology Laboratory, Microbiology and Parasitology Department, Hospital Ramón y Cajal-IRYCIS and CIBEREsp-RITIP-CoRISpe, 20834 Madrid, Spain
- Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), 28029 Madrid, Spain
| |
Collapse
|
3
|
Rodríguez-Galet A, Rubio-Garrido M, Valadés-Alcaraz A, Rodríguez-Domínguez M, Galán JC, Ndarabu A, Reina G, Holguín A. Immune surveillance for six vaccinable pathogens using paired plasma and dried blood spots in HIV infected and uninfected children in Kinshasa. Sci Rep 2022; 12:7920. [PMID: 35562589 PMCID: PMC9106688 DOI: 10.1038/s41598-022-12052-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Accepted: 05/03/2022] [Indexed: 11/29/2022] Open
Abstract
Child vaccination reduces infant mortality rates. HIV-infected children present higher risk of diseases than non-infected. We report the protection coverage rates for 6 vaccine-preventable diseases in a paediatric population from the Democratic Republic of the Congo (DRC) and the impact of HIV infection, providing the first data on the validity of dried blood samples (DBS) to monitor the immune protection. During 2016-2018 DBS from 143 children/adolescents were collected in Kinshasa (DRC), being 52 HIV-infected. Forty-two had a paired plasma sample. Protective IgG was quantified (VirClia-IgG,VIRCELL) to obtain the optimal cut-off in IgG detection in DBS. ROC curves were generated with R software and statistical analyses with Stata. Protective IgG levels varied across pathogens, not reaching herd immunity. HIV-infected presented lower vaccine protection than uninfected for all analyzed pathogens, except rubella, with statistically significant differences for measles (30.8% vs. 53.8%; p = 0.008) and tetanus (3.8% vs. 22%; p = 0.0034). New cut-offs were calculated when using DBS to improve test performance. We reinforce the necessity to increase pediatric vaccination coverage in Kinshasa, especially in HIV seropositive, with less capacity to maintain adequate antibody levels. DBS were useful to monitor vaccination coverage in seroprevalence studies in resource-limited settings, after optimizing the cut-off value for each pathogen.
Collapse
Affiliation(s)
- A Rodríguez-Galet
- HIV Molecular Epidemiology Laboratory, Microbiology Department, Ramón y Cajal University Hospital-IRYCIS-CIBERESp-RITIP-CoRISpe, Carretera de Colmenar, Km.9, 100, 28034, Madrid, Spain
| | - M Rubio-Garrido
- HIV Molecular Epidemiology Laboratory, Microbiology Department, Ramón y Cajal University Hospital-IRYCIS-CIBERESp-RITIP-CoRISpe, Carretera de Colmenar, Km.9, 100, 28034, Madrid, Spain
| | - A Valadés-Alcaraz
- HIV Molecular Epidemiology Laboratory, Microbiology Department, Ramón y Cajal University Hospital-IRYCIS-CIBERESp-RITIP-CoRISpe, Carretera de Colmenar, Km.9, 100, 28034, Madrid, Spain
| | - M Rodríguez-Domínguez
- Microbiology Department, Ramón y Cajal University Hospital, Madrid, Spain
- CIBER in Epidemiology and Public Health (CIBERESP), Madrid, Spain
| | - J C Galán
- Microbiology Department, Ramón y Cajal University Hospital, Madrid, Spain
- CIBER in Epidemiology and Public Health (CIBERESP), Madrid, Spain
| | - A Ndarabu
- Monkole Hospital, Kinshasa, Democratic Republic of the Congo
| | - G Reina
- Microbiology Department, University of Navarra Clinic-IdiSNA, Pamplona, Spain
| | - A Holguín
- HIV Molecular Epidemiology Laboratory, Microbiology Department, Ramón y Cajal University Hospital-IRYCIS-CIBERESp-RITIP-CoRISpe, Carretera de Colmenar, Km.9, 100, 28034, Madrid, Spain.
- CIBER in Epidemiology and Public Health (CIBERESP), Madrid, Spain.
| |
Collapse
|
4
|
Hayashida T, Takano M, Tsuchiya K, Aoki T, Gatanaga H, Kaneko N, Oka S. Validation of mailed via postal service dried blood spot cards on commercially available HIV testing systems. Glob Health Med 2021; 3:394-400. [PMID: 35036621 DOI: 10.35772/ghm.2021.01105] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 10/04/2021] [Accepted: 11/01/2021] [Indexed: 01/29/2023]
Abstract
The demand for HIV testing using dried blood spots (DBS) has increased recently. However, DBS is not an approved sample for HIV testing in Japan. This study examined the validation of HIV testing with DBS, prepared at the laboratory or remotely and mailed via postal service to the laboratory. DBS were punched out from a 5.5 mm diameter circle on filter paper, then eluted with 600 μL of phosphate buffered saline overnight at 4℃, and analyzed by Lumipulse S HIVAg/Ab (LUM). The mean LUM count of DBS was 237.4-times diluted compared to titrated plasma. Repeated sample testing showed that although LUM count of DBS decreased slightly with increase in sample storage time (up to one month), it did not affect the result of HIV testing with DBS. Based on testing of 50 HIV+ confirmed cases and 50 HIV- persons, the estimated sensitivity was 98% (49/50) with a specificity of 100% when the cut-off value is 0.5. The single false negative case was a patient with undetectable viral load over the last 10 years, resulting in a decrease of antibody titer below the cut-off level. In conclusion, although DBS cannot completely replace plasma in HIV testing because the sensitivity was a little lower than that of plasma, it can be potentially useful for a screening test by self-finger-prick and postal service use. This will allow people to receive HIV testing without visiting public health centers.
Collapse
Affiliation(s)
- Tsunefusa Hayashida
- AIDS Clinical Center, National Center for Global Health and Medicine, Tokyo, Japan
| | - Misao Takano
- AIDS Clinical Center, National Center for Global Health and Medicine, Tokyo, Japan
| | - Kiyoto Tsuchiya
- AIDS Clinical Center, National Center for Global Health and Medicine, Tokyo, Japan
| | - Takahiro Aoki
- AIDS Clinical Center, National Center for Global Health and Medicine, Tokyo, Japan
| | - Hiroyuki Gatanaga
- AIDS Clinical Center, National Center for Global Health and Medicine, Tokyo, Japan
| | - Noriyo Kaneko
- School of Nursing, Nagoya City University, Nagoya, Japan
| | - Shinichi Oka
- AIDS Clinical Center, National Center for Global Health and Medicine, Tokyo, Japan
| |
Collapse
|
5
|
Barquín D, Ndarabu A, Carlos S, Fernández-Alonso M, Rubio-Garrido M, Makonda B, Holguín Á, Reina G. HIV-1 diagnosis using dried blood spots from patients in Kinshasa, DRC: a tool to detect misdiagnosis and achieve World Health Organization 2030 targets. Int J Infect Dis 2021; 111:253-260. [PMID: 34419584 DOI: 10.1016/j.ijid.2021.08.035] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 08/16/2021] [Accepted: 08/17/2021] [Indexed: 10/20/2022] Open
Abstract
INTRODUCTION Currently, only 54% of the population of the Democratic Republic of the Congo (DRC) know their HIV status. The aim of this study was to detect HIV misdiagnosis from rapid diagnostic tests (RDT) and to evaluate serological immunoassays using dried blood spots (DBS) from patients in Kinshasa, DRC. METHODS Between 2016 and 2018, 365 DBS samples were collected from 363 individuals and shipped to Spain. The samples were from people with a new HIV positive (n = 123) or indeterminate (n = 23) result, known HIV-positive patients (n = 157), and a negative control group (n = 62). HIV serology was performed using Elecsys HIV combi PT (Roche), VIDAS HIV Duo Quick (BioMérieux), and Geenius (Bio-Rad). In addition, HIV RNA detection was performed in all samples using the COBAS AmpliPrep/COBAS Taqman HIV-1 Test 2.0 (Roche). RESULTS Overall, 272 samples were found to be positive and 93 to be negative for HIV serology. The sensitivity was 100% for both Elecsys and VIDAS techniques, but specificity was slightly higher for the VIDAS test: 100% (96.1-100%) vs 98.9% (94.1-99.9%). Of the 23 indeterminate cases using RDT, only three cases were true-positives with a detectable viral load. Eleven samples out of the 280 classified as positive by RDT corresponded to nine patients who had received a false diagnosis of HIV through RDT (3.9%); six of them had been on antiretroviral therapy for at least 2 years. CONCLUSIONS Elecsys HIV combi PT and VIDAS HIV Duo Quick immunoassays showed high sensitivity and specificity when using DBS. RDT-based serological diagnosis can lead to HIV misdiagnosis with personal and social consequences in sub-Saharan Africa.
Collapse
Affiliation(s)
- David Barquín
- Microbiology Department, Clínica Universidad de Navarra, Pamplona, Spain
| | - Adolphe Ndarabu
- Centre Hospitalier Monkole, Kinshasa, Democratic Republic of the Congo
| | - Silvia Carlos
- ISTUN, Institute of Tropical Health, Universidad de Navarra, Pamplona, Spain; IdiSNA, Navarra Institute for Health Research, Pamplona, Spain; Department of Preventive Medicine and Public Health, Universidad de Navarra, Pamplona, Spain
| | - Mirian Fernández-Alonso
- Microbiology Department, Clínica Universidad de Navarra, Pamplona, Spain; ISTUN, Institute of Tropical Health, Universidad de Navarra, Pamplona, Spain; IdiSNA, Navarra Institute for Health Research, Pamplona, Spain
| | - Marina Rubio-Garrido
- HIV-1 Molecular Epidemiology Laboratory, Microbiology and Parasitology Department, University Hospital Ramón y Cajal-IRYCIS and CIBEREsp-RITIP, Madrid, Spain
| | - Benit Makonda
- Centre Hospitalier Monkole, Kinshasa, Democratic Republic of the Congo
| | - África Holguín
- HIV-1 Molecular Epidemiology Laboratory, Microbiology and Parasitology Department, University Hospital Ramón y Cajal-IRYCIS and CIBEREsp-RITIP, Madrid, Spain
| | - Gabriel Reina
- Microbiology Department, Clínica Universidad de Navarra, Pamplona, Spain; ISTUN, Institute of Tropical Health, Universidad de Navarra, Pamplona, Spain; IdiSNA, Navarra Institute for Health Research, Pamplona, Spain.
| |
Collapse
|
6
|
Rubio-Garrido M, Avendaño-Ortiz J, Ndarabu A, Rubio C, Reina G, López-Collazo E, Holguín Á. Dried Blood Specimens as an Alternative Specimen for Immune Response Monitoring During HIV Infection: A Proof of Concept and Simple Method in a Pediatric Cohort. Front Med (Lausanne) 2021; 8:678850. [PMID: 34211989 PMCID: PMC8239183 DOI: 10.3389/fmed.2021.678850] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Accepted: 05/07/2021] [Indexed: 01/23/2023] Open
Abstract
Programs to prevent mother-to-child HIV transmission do not reduce the number of infants exposed during pregnancy and breastfeeding. HIV-exposed but uninfected children (HEU) present higher risk of morbidity and mortality than HIV-unexposed and uninfected children (UU). In this line, the study of immune biomarkers in HIV could improve prediction of disease progression, allowing to diminish comorbidity risk. Dried blood specimens (DBS) are an alternative to serum for collecting and transporting samples in countries with limited infrastructure and especially interesting for groups such as pediatrics, where obtaining a high sample volume is challenging. This study explores the usefulness of DBS for immune profile monitoring in samples from 30 children under clinical follow-up in Kinshasa: 10 HIV-infected (HIV+), 10 HEU, and 10 UU. We have measured the gene expression levels of 12 immune and inflammatory markers (CD14, IL-6, TNFα, HVEM, B7.1, HIF-1α, Siglec-10, IRAK-M, CD163, B7H5, PD-L1, and Galectin-9) in DBS samples by reverse transcription of total RNA and RT-qPCR. Principal component analysis, Kruskal-Wallis test, and Mann-Whitney test were performed in order to study group differences. HIV+ children presented significantly higher levels of seven biomarkers (CD14, IL-6 HVEM, B7.1, Siglec-10, HIF-1α, and CD163) than the UU group. In HEU, we found seven biomarkers significantly elevated (CD14, IL-6, HVEM, B7.1, Siglec-10, HIF-1α, and IRAK-M) vs. UU. Six biomarkers (CD14, IL-6, HVEM, B7.1, Siglec-10, and HIF-1α) showed a significantly higher expression in both HIV+ and HEU vs. UU, with HVEM and CD14 being significantly overexpressed among HIV+ vs. HEU. Our data reveal the utility of DBS for immune response monitoring. Moreover, significant differences in specific biomarker expression across groups strongly suggest the effect of HIV infection and/or HIV exposure on these immune biomarkers' expressions.
Collapse
Affiliation(s)
- Marina Rubio-Garrido
- HIV-1 Molecular Epidemiology Laboratory, Microbiology Department, Ramón y Cajal University Hospital- Instituto Ramón y Cajal para la Investigación Sanitaria (IRYCIS) and Centro de Investigación Biomédica en Red de Epidemiología y Salud Pública - Red de Investigación Traslacional en Infectología Pediátrica (CIBERESP-RITIP), Madrid, Spain
| | - José Avendaño-Ortiz
- Innate Immunity Group, Hospital La Paz Institute for Health Research, La Paz University Hospital, Madrid, Spain.,Tumor Immunology Laboratory and Innate Immunity Group, Hospital La Paz Institute for Health Research, La Paz University Hospital, Madrid, Spain
| | | | - Carolina Rubio
- Tumor Immunology Laboratory and Innate Immunity Group, Hospital La Paz Institute for Health Research, La Paz University Hospital, Madrid, Spain
| | | | - Eduardo López-Collazo
- Innate Immunity Group, Hospital La Paz Institute for Health Research, La Paz University Hospital, Madrid, Spain.,Tumor Immunology Laboratory and Innate Immunity Group, Hospital La Paz Institute for Health Research, La Paz University Hospital, Madrid, Spain
| | - África Holguín
- HIV-1 Molecular Epidemiology Laboratory, Microbiology Department, Ramón y Cajal University Hospital- Instituto Ramón y Cajal para la Investigación Sanitaria (IRYCIS) and Centro de Investigación Biomédica en Red de Epidemiología y Salud Pública - Red de Investigación Traslacional en Infectología Pediátrica (CIBERESP-RITIP), Madrid, Spain
| |
Collapse
|
7
|
Amini F, Auma E, Hsia Y, Bilton S, Hall T, Ramkhelawon L, Heath PT, Le Doare K. Reliability of dried blood spot (DBS) cards in antibody measurement: A systematic review. PLoS One 2021; 16:e0248218. [PMID: 33720928 PMCID: PMC7959368 DOI: 10.1371/journal.pone.0248218] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Accepted: 02/23/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Increasingly, vaccine efficacy studies are being recommended in low-and-middle-income countries (LMIC), yet often facilities are unavailable to take and store infant blood samples correctly. Dried blood spots (DBS), are useful for collecting blood from infants for diagnostic purposes, especially in low-income settings, as the amount of blood required is miniscule and no refrigeration is required. Little is known about their utility for antibody studies in children. This systematic review aims to investigate the correlation of antibody concentrations against infectious diseases in DBS in comparison to serum or plasma samples that might inform their use in vaccine clinical trials. METHODS AND FINDINGS We searched MEDLINE, Embase and the Cochrane library for relevant studies between January 1990 to October 2020 with no language restriction, using PRISMA guidelines, investigating the correlation between antibody concentrations in DBS and serum or plasma samples, and the effect of storage temperature on DBS diagnostic performance. We included 40 studies in this systematic review. The antibody concentration in DBS and serum/plasma samples reported a good pooled correlation, (r2 = 0.86 (ranged 0.43 to 1.00)). Ten studies described a decline of antibody after 28 days at room temperature compared to optimal storage at -20°C, where antibodies were stable for up to 200 days. There were only five studies of anti-bacterial antibodies. CONCLUSIONS There is a good correlation between antibody concentrations in DBS and serum/plasma samples, supporting the wider use of DBS in vaccine and sero-epidemiological studies, but there is limited data on anti-bacterial antibodies. The correct storage of DBS is critical and may be a consideration for longer term storage.
Collapse
Affiliation(s)
- Fahimah Amini
- Paediatric Infectious Disease Research Group, Institute for Infection and Immunity, St. George’s University of London, London, United Kingdom
| | - Erick Auma
- Department of Biology, University of Lyon, Université Claude Bernard Lyon, ENS de Lyon, CNRS, UMR, Lyon, France
| | - Yingfen Hsia
- Paediatric Infectious Disease Research Group, Institute for Infection and Immunity, St. George’s University of London, London, United Kingdom
- School of Pharmacy, Queen’s University Belfast, Belfast, United Kingdom
| | - Sam Bilton
- St Georges University Hospitals NHS Foundation Trust, Tooting, London, United Kingdom
| | - Tom Hall
- Paediatric Infectious Disease Research Group, Institute for Infection and Immunity, St. George’s University of London, London, United Kingdom
| | - Laxmee Ramkhelawon
- Paediatric Infectious Disease Research Group, Institute for Infection and Immunity, St. George’s University of London, London, United Kingdom
| | - Paul T. Heath
- Paediatric Infectious Disease Research Group, Institute for Infection and Immunity, St. George’s University of London, London, United Kingdom
- St Georges University Hospitals NHS Foundation Trust, Tooting, London, United Kingdom
| | - Kirsty Le Doare
- Paediatric Infectious Disease Research Group, Institute for Infection and Immunity, St. George’s University of London, London, United Kingdom
- St Georges University Hospitals NHS Foundation Trust, Tooting, London, United Kingdom
- Pathogen Immunology Group, Public Health England, Porton Down, United Kingdom
| |
Collapse
|
8
|
Assessing donor suitability for blood donation: Utility of Geenius HIV 1/2 confirmatory assay. Transfus Apher Sci 2020; 60:103008. [PMID: 33183985 DOI: 10.1016/j.transci.2020.103008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 10/25/2020] [Accepted: 10/31/2020] [Indexed: 11/22/2022]
Abstract
BACKGROUND Blood donor care and blood safety require a quick and accurate decision on the presence or absence of Human Immunodeficiency Virus (HIV) infection, based on the proper selection of blood donors, serological and molecular HIV testing as well as western blot test. The aim was investigating the possibility of inclusion of Geenius HIV 1/2 Confirmatory Assay in blood donor testing algorithm in order to shorten test time and decrease the number of indeterminate results. METHODS A total of 75 archived serum/plasma samples were tested. Their previous serological and molecular HIV results were: 3 negative samples, 7 positive samples, 65 serological indeterminate or positive but confirmatory testing and NAT negative samples. RESULTS Geenius assay confirmed the presence of antibodies in all blood donors with HIV positive serology and Nucleic Acid Testing (NAT). HIV-1 gp160 and gp41 antibodies were detected in these donors, while p31 and p24 antibodies were not detected in two and three donors, respectively. HIV-2 antibodies gp36 and gp140 were not found. Blood donor with HIV indeterminate or positive serology but negative confirmatory testing and NAT, were negative in Geenius assay. Conclusion The results obtained are consistent with western blot results. The assay proved simple and quick to perform. Studies have confirmed the possibility of introducing Bio-Rad Geenius into a routine blood donor testing protocol.
Collapse
|
9
|
High level of HIV false positives using EIA-based algorithm in survey: Importance of confirmatory testing. PLoS One 2020; 15:e0239782. [PMID: 33091019 PMCID: PMC7580971 DOI: 10.1371/journal.pone.0239782] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Accepted: 09/12/2020] [Indexed: 12/20/2022] Open
Abstract
The Mozambique Indicators of Immunization, Malaria and HIV/AIDS (IMASIDA) survey was conducted in 2015 and used a two Enzyme Immunoassay (EIA) (Vironostika HIV-1/2 and Murex HIV-1/2) based algorithm to determine the HIV status of the consented participants. The Mozambique Ministry of Health, with support from the US Centers for Disease Control and Prevention (US CDC), added Bio-Rad Geenius™ HIV-1/2 Supplemental Assay to the IMASIDA HIV testing algorithm to confirm all specimens that were found to be reactive on one or both EIAs. In total 11690 specimens were collected to estimate the proportion of HIV positive samples. Results indicate that the proportion of HIV positive samples based on the concordant positive results of two EIA assays was 21.5% (2518/11690). The addition of the Geenius assay to the IMASIDA HIV testing algorithm demonstrated that 792 (31.5%) of 2518 specimens were false-positive and reduced the proportion of HIV positive samples to 14.7% (1722/11690), demonstrating the importance of including a highly specific HIV test to confirm HIV diagnosis. HIV surveys exclusively based on EIA testing algorithm may result in misleading high prevalence results. Our results demonstrate that more specific confirmatory testing should be added to the EIA-based algorithms to ensure accurate HIV diagnosis and correct HIV prevalence estimate in cross-sectional surveys.
Collapse
|
10
|
Rubio-Garrido M, Ndarabu A, Reina G, Barquín D, Fernández-Alonso M, Carlos S, Holguín Á. Utility Of POC Xpert HIV-1 Tests For Detection-Quantification Of Complex HIV Recombinants Using Dried Blood Spots From Kinshasa, D. R. Congo. Sci Rep 2019; 9:5679. [PMID: 30952893 PMCID: PMC6450884 DOI: 10.1038/s41598-019-41963-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Accepted: 03/18/2019] [Indexed: 01/05/2023] Open
Abstract
Point-of-Care (POC) molecular assays improve HIV infant diagnosis and viral load (VL) quantification in resource-limited settings. We evaluated POC performance in Kinshasa (Democratic Republic of Congo), with high diversity of HIV-1 recombinants. In 2016, 160 dried blood samples (DBS) were collected from 85 children (60 HIV-, 18 HIV+, 7 HIV-exposed) and 75 HIV+ adults (65 treated, 10 naive) at Monkole Hospital (Kinshasa). We compared viraemia with Cepheid-POC-Xpert-HIV-1VL and the non-POC-COBAS®AmpliPrep/COBAS®TaqMan®HIV-1-Testv2 in all HIV+, carrying 72.4%/7.2% HIV-1 unique/complex recombinant forms (URF/CRF). HIV-1 infection was confirmed in 14 HIV+ children by Cepheid-POC-Xpert-HIV-1Qual and in 70 HIV+ adults by both Xpert-VL and Roche-VL, identifying 8 false HIV+ diagnosis performed in DRC (4 adults, 4 children). HIV-1 was detected in 95.2% and 97.6% of 84 HIV+ samples by Xpert-VL and Roche-VL, respectively. Most (92.9%) HIV+ children presented detectable viraemia by both VL assays and 74.3% or 72.8% of 70 HIV+ adults by Xpert or Roche, respectively. Both VL assays presented high correlation (R2 = 0.89), but showing clinical relevant ≥0.5 log VL differences in 15.4% of 78 cases with VL within quantification range by both assays. This is the first study confirming the utility of Xpert HIV-1 tests for detection-quantification of complex recombinants currently circulating in Kinshasa.
Collapse
Affiliation(s)
- Marina Rubio-Garrido
- HIV-1 Molecular Epidemiology Laboratory, Microbiology and Parasitology Department, University Hospital Ramón y Cajal-IRYCIS and CIBEREsp-RITIP, Madrid, 28034, Spain
| | - Adolphe Ndarabu
- Monkole Hospital, Kinshasa, Democratic Republic of the Congo
| | - Gabriel Reina
- Microbiology Department, Clínica Universidad de Navarra, Navarra Institute for Health Research (IdiSNA), Institute of Tropical Health, Universidad de Navarra (ISTUN), Pamplona, 31008, Spain.
| | - David Barquín
- Microbiology Department, Clínica Universidad de Navarra, Navarra Institute for Health Research (IdiSNA), Institute of Tropical Health, Universidad de Navarra (ISTUN), Pamplona, 31008, Spain
| | - Mirian Fernández-Alonso
- Microbiology Department, Clínica Universidad de Navarra, Navarra Institute for Health Research (IdiSNA), Institute of Tropical Health, Universidad de Navarra (ISTUN), Pamplona, 31008, Spain
| | - Silvia Carlos
- Department of Preventive Medicine and Public Health, Institute of Culture and Society (ICS), Institute of Tropical Health (ISTUN), Universidad de Navarra, Navarra Institute for Health Research (IdiSNA), Pamplona, 31008, Spain
| | - África Holguín
- HIV-1 Molecular Epidemiology Laboratory, Microbiology and Parasitology Department, University Hospital Ramón y Cajal-IRYCIS and CIBEREsp-RITIP, Madrid, 28034, Spain
| |
Collapse
|
11
|
Stability of Human Immunodeficiency Virus Serological Markers in Samples Collected as HemaSpot and Whatman 903 Dried Blood Spots. J Clin Microbiol 2018; 56:JCM.00933-18. [PMID: 30045869 DOI: 10.1128/jcm.00933-18] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Accepted: 07/13/2018] [Indexed: 11/20/2022] Open
Abstract
Dried blood spots (DBS) are frequently used in clinical testing for biosurveillance, infectious disease and confirmatory testing, and clinical trials, particularly for populations in remote areas. The HemaSpot-HF blood collection device (HS) provides an alternative format to the Whatman 903 cards (903) to simplify sample collection and processing. In this study, the performance of the HS was compared to that of the 903 using previously characterized clinical specimens and HIV seroconversion panels known to exhibit markers of early human immunodeficiency virus (HIV) infection. HS and 903 samples were prepared and tested by Bio-Rad GS HIV Combo Ag/Ab enzyme immunoassay (EIA), GS HIV-1/-2 Plus O EIA, GS HIV-1 Western blot, and HIV-1 Geenius assays. Both HS and 903 performed well for up to 6 months at room temperature, but a marked loss of Western blot and low titer antibody signals from early infection samples was observed in samples stored for 180 days at elevated (37 to 45°C) temperatures and high humidity (95%). HemaSpot samples placed in sealed bags with additional desiccant were protected from degradation and showed improved signal recovery relative to that of the 903. HS was easier to use than the 903 and showed higher sensitivity and reproducibility for early infection samples and improved stability.
Collapse
|
12
|
Luo W, Davis G, Li L, Shriver MK, Mei J, Styer LM, Parker MM, Smith A, Paz-Bailey G, Ethridge S, Wesolowski L, Owen SM, Masciotra S. Evaluation of dried blood spot protocols with the Bio-Rad GS HIV Combo Ag/Ab EIA and Geenius™ HIV 1/2 Supplemental Assay. J Clin Virol 2017; 91:84-89. [PMID: 28366544 PMCID: PMC11111259 DOI: 10.1016/j.jcv.2017.03.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Revised: 03/15/2017] [Accepted: 03/15/2017] [Indexed: 11/20/2022]
Abstract
OBJECTIVE FDA-approved antigen/antibody combo and HIV-1/2 differentiation supplemental tests do not have claims for dried blood spot (DBS) use. We compared two DBS-modified protocols, the Bio-Rad GS HIV Combo Ag/Ab (BRC) EIA and Geenius™ HIV-1/2 (Geenius) Supplemental Assay, to plasma protocols and evaluated them in the CDC/APHL HIV diagnostic algorithm. METHODS BRC-DBS p24 analytical sensitivity was calculated from serial dilutions of p24. DBS specimens included 11 HIV-1 seroconverters, 151 HIV-1-positive individuals, including 20 on antiretroviral therapy, 31 HIV-2-positive and one HIV-1/HIV-2-positive individuals. BRC-reactive specimens were tested with Geenius using the same DBS eluate. Matched plasma specimens were tested with BRC, an IgG/IgM immunoassay and Geenius. DBS and plasma results were compared using the McNemar's test. A DBS-algorithm applied to 348 DBS from high-risk individuals who participated in surveillance was compared to HIV status based on local testing algorithms. RESULTS BRC-DBS detects p24 at a concentration 18 times higher than in plasma. In seroconverters, BRC-DBS detected more infections than the IgG/IgM immunoassay in plasma (p=0.0133), but fewer infections than BRC-plasma (p=0.0133). In addition, the BRC/Geenius-plasma algorithm identified more HIV-1 infections than the BRC/Geenius-DBS algorithm (p=0.0455). The DBS protocols correctly identified HIV status for established HIV-1 infections, including those on therapy, HIV-2 infections, and surveillance specimens. CONCLUSIONS The DBS protocols exhibited promising performance and allowed rapid supplemental testing. Although the DBS algorithm missed some early infections, it showed similar results when applied to specimens from a high-risk population. Implementation of a DBS algorithm would benefit testing programs without capacity for venipuncture.
Collapse
Affiliation(s)
- Wei Luo
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| | | | - LiXia Li
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| | | | - Joanne Mei
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| | - Linda M Styer
- Wadsworth Center, New York State Department of Health, Albany, NY, USA
| | - Monica M Parker
- Wadsworth Center, New York State Department of Health, Albany, NY, USA
| | - Amanda Smith
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| | | | - Steve Ethridge
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| | | | - S Michele Owen
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| | | |
Collapse
|
13
|
Joseph J, Kent N, Bowen A, Hart J, Sheel M, Wardrop R, Abbs S, Bazely S, Rybak M. Immuno-nephelometric determination of group streptococcal anti-streptolysin O titres (ASOT) from dried blood spots: Method for validating a new assay. J Immunol Methods 2017; 448:59-65. [PMID: 28554544 DOI: 10.1016/j.jim.2017.05.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2017] [Accepted: 05/23/2017] [Indexed: 11/24/2022]
Abstract
This study was designed to determine the sensitivity and reproducibility of recovering anti-streptolysin O titres (ASOT) from dried blood spot (DBS) samples, a methodologic subcomponent of the penicillin pharmacokinetic studies in children receiving secondary prophylaxis with intramuscular benzathine penicillin for acute rheumatic fever.
Collapse
Affiliation(s)
- John Joseph
- PathWest Laboratory Medicine, QE2 Medical Centre Redevelopment, Australia.
| | - Neil Kent
- PathWest Laboratory Medicine, QE2 Medical Centre Redevelopment, Australia
| | - Asha Bowen
- Menzies School of Health Research, Charles Darwin University, Australia; Wesfarmers Centre for Vaccines and Infectious Diseases, Telethon Kids Institute, University of Western Australia, Australia; Princess Margaret Hospital for Children, Australia; University of Western Australia, Australia
| | - Julie Hart
- PathWest Laboratory Medicine, QE2 Medical Centre Redevelopment, Australia
| | - Meru Sheel
- Wesfarmers Centre for Vaccines and Infectious Diseases, Telethon Kids Institute, University of Western Australia, Australia
| | | | - Sam Abbs
- PathWest Laboratory Medicine, QE2 Medical Centre Redevelopment, Australia
| | | | - Monika Rybak
- PathWest Laboratory Medicine, QE2 Medical Centre Redevelopment, Australia
| |
Collapse
|
14
|
HIV-1 variability and viral load technique could lead to false positive HIV-1 detection and to erroneous viral quantification in infected specimens. J Infect 2015; 71:368-76. [PMID: 26033694 DOI: 10.1016/j.jinf.2015.05.011] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2015] [Revised: 05/12/2015] [Accepted: 05/25/2015] [Indexed: 11/23/2022]
Abstract
OBJECTIVES Viral load (VL) testing is used for early HIV diagnosis in infants (EID) and for detecting early therapeutic failure events, but can be affected by HIV genetic variability. Dried blood samples (DBS) increase VL access and EID in remote settings and when low blood volume is available. METHODS This study compares VL values using Siemens VERSANT HIV-1 RNA 1.0 kPCR assay (kPCR) and Roche CAP/CTM Quantitative test v2.0 (CAP/CTM v2.0) in 176 DBS carrying different HIV-1 variants collected from 69 Equatoguinean mothers and their infants with known HIV-1 status (71 infected, 105 uninfected). RESULTS CAP/CTM v2.0 provided false positive VLs in 11 (10.5%) cases. VL differences above 0.5 log10 were observed in 42/49 (87.5%) DBS, and were above 1 log10 in 18 cases. CAP/CTM v2.0 quantified all the 41 specimens with previously inferred HIV-1 variant by phylogenetic analysis (68.3% recombinants) whereas kPCR only identified 90.2% of them, and was unable to detect 14.3% of 21 CRF02_AG viruses. CAP/CTM v2.0 showed higher sensitivity than kPCR (95.8% vs. 70.1%), quantifying a higher rate of viruses in infected DBS from subjects under antiretroviral exposure at sampling time compared to kPCR (94.7% vs. 96.2%, p-value<0.001). kPCR showed maximum specificity (100%) whereas for CAP/CTM v2.0 was 89.5%. CONCLUSIONS VL assays should increase their sensitivity and specificity to avoid overestimated HIV-1 quantifications, which could be interpreted as virological failure events, or false negative diagnostic results due to genetic variability. We recommend using the same VL technique for each patient during antiretroviral therapy monitoring.
Collapse
|