1
|
Aerosolized Hydrogen Peroxide Decontamination of N95 Respirators, with Fit-Testing and Viral Inactivation, Demonstrates Feasibility for Reuse during the COVID-19 Pandemic. mSphere 2022; 7:e0030322. [PMID: 36040048 PMCID: PMC9599425 DOI: 10.1128/msphere.00303-22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
In response to the demand for N95 respirators by health care workers during the COVID-19 pandemic, we evaluated decontamination of N95 respirators using an aerosolized hydrogen peroxide (aHP) system. This system is designed to dispense a consistent atomized spray of aerosolized, 7% hydrogen peroxide (H2O2) solution over a treatment cycle. Multiple N95 respirator models were subjected to 10 or more cycles of respirator decontamination, with a select number periodically assessed for qualitative and quantitative fit testing. In parallel, we assessed the ability of aHP treatment to inactivate multiple viruses absorbed onto respirators, including phi6 bacteriophage, herpes simplex virus 1 (HSV-1), coxsackievirus B3 (CVB3), and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). For pathogens transmitted via respiratory droplets and aerosols, it is critical to address respirator safety for reuse. This study provided experimental validation of an aHP treatment process that decontaminates the respirators while maintaining N95 function. External National Institute for Occupational Safety & Health (NIOSH) certification verified respirator structural integrity and filtration efficiency after 10 rounds of aHP treatment. Virus inactivation by aHP was comparable to the decontamination of commercial spore-based biological indicators. These data demonstrate that the aHP process is effective, with successful fit-testing of respirators after multiple aHP cycles, effective decontamination of multiple virus species, including SARS-CoV-2, successful decontamination of bacterial spores, and filtration efficiency maintained at or greater than 95%. While this study did not include extended or clinical use of N95 respirators between aHP cycles, these data provide proof of concept for aHP decontamination of N95 respirators before reuse in a crisis-capacity scenario. IMPORTANCE The COVID-19 pandemic led to unprecedented pressure on health care and research facilities to provide personal protective equipment. The respiratory nature of the SARS-CoV2 pathogen makes respirator facepieces a critical protective measure to limit inhalation of this virus. While respirator facepieces were designed for single use and disposal, the pandemic increased overall demand for N95 respirators, and corresponding manufacturing and supply chain limitations necessitated the safe reuse of respirators when necessary. In this study, we repurposed an aerosolized hydrogen peroxide (aHP) system that is regularly utilized to decontaminate materials in a biosafety level 3 (BSL3) facility, to develop a method for decontamination of N95 respirators. Results from viral inactivation, biological indicators, respirator fit testing, and filtration efficiency testing all indicated that the process was effective at rendering N95 respirators safe for reuse. This proof-of-concept study establishes baseline data for future testing of aHP in crisis-capacity respirator-reuse scenarios.
Collapse
|
2
|
Augustyn W, Chruściel A, Hreczuch W, Kalka J, Tarka P, Kierat W. Inactivation of Spores and Vegetative Forms of Clostridioides difficile by Chemical Biocides: Mechanisms of Biocidal Activity, Methods of Evaluation, and Environmental Aspects. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19020750. [PMID: 35055571 PMCID: PMC8775970 DOI: 10.3390/ijerph19020750] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 01/03/2022] [Accepted: 01/04/2022] [Indexed: 12/15/2022]
Abstract
Clostridioides difficile infections (CDIs) are the most common cause of acquired diseases in hospitalized patients. Effective surface disinfection, focused on the inactivation of the spores of this pathogen, is a decisive factor in reducing the number of nosocomial cases of CDI infections. An efficient disinfection procedure is the result of both the properties of the biocidal agent used and the technology of its implementation as well as a reliable, experimental methodology for assessing the activity of the biocidal active substance based on laboratory models that adequately represent real clinical conditions. This study reviews the state of knowledge regarding the properties and biochemical basis of the action mechanisms of sporicidal substances, with emphasis on chlorine dioxide (ClO2). Among the analyzed biocides, in addition to ClO2, active chlorine, hydrogen peroxide, peracetic acid, and glutaraldehyde were characterized. Due to the relatively high sporicidal effectiveness and effective control of bacterial biofilm, as well as safety in a health and environmental context, the use of ClO2 is an attractive alternative in the control of nosocomial infections of CD etiology. In terms of the methods of assessing the biocidal effectiveness, suspension and carrier standards are discussed.
Collapse
Affiliation(s)
- Weronika Augustyn
- MEXEO-Wiesław Hreczuch, Energetyków 9, 47-225 Kędzierzyn-Koźle, Poland; (W.A.); (W.H.)
- Environmental Biotechnology Department, Silesian University of Technology, Faculty of Power and Environmental Engineering, 44-100 Gliwice, Poland;
| | - Arkadiusz Chruściel
- MEXEO-Wiesław Hreczuch, Energetyków 9, 47-225 Kędzierzyn-Koźle, Poland; (W.A.); (W.H.)
- Correspondence:
| | - Wiesław Hreczuch
- MEXEO-Wiesław Hreczuch, Energetyków 9, 47-225 Kędzierzyn-Koźle, Poland; (W.A.); (W.H.)
| | - Joanna Kalka
- Environmental Biotechnology Department, Silesian University of Technology, Faculty of Power and Environmental Engineering, 44-100 Gliwice, Poland;
| | - Patryk Tarka
- Department of Social Medicine and Public Health, Medical University of Warsaw, 02-007 Warszawa, Poland;
| | - Wojciech Kierat
- Department of Digital Systems, Silesian University of Technology, 44-100 Gliwice, Poland;
| |
Collapse
|
3
|
Airborne Disinfection by Dry Fogging Efficiently Inactivates Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), Mycobacteria, and Bacterial Spores and Shows Limitations of Commercial Spore Carriers. Appl Environ Microbiol 2021; 87:AEM.02019-20. [PMID: 33158901 PMCID: PMC7848922 DOI: 10.1128/aem.02019-20] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Accepted: 11/05/2020] [Indexed: 11/30/2022] Open
Abstract
Airborne disinfection is not only of crucial importance for the safe operation of laboratories and animal rooms where infectious agents are handled but also can be used in public health emergencies such as the current severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. We show that dry fogging an aerosolized mixture of peroxyacetic acid and hydrogen peroxide (aPAA-HP) is highly microbicidal, efficient, fast, robust, environmentally neutral, and a suitable airborne disinfection method. Airborne disinfection of high-containment facilities before maintenance or between animal studies is crucial. Commercial spore carriers (CSC) coated with 106 spores of Geobacillus stearothermophilus are often used to assess the efficacy of disinfection. We used quantitative carrier testing (QCT) procedures to compare the sensitivity of CSC with that of surrogates for nonenveloped and enveloped viruses, including severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), mycobacteria, and spores, to an aerosolized mixture of peroxyacetic acid and hydrogen peroxide (aPAA-HP). We then used the QCT methodology to determine relevant process parameters to develop and validate effective disinfection protocols (≥4-log10 reduction) in various large and complex facilities. Our results demonstrate that aPAA-HP is a highly efficient procedure for airborne room disinfection. Relevant process parameters such as temperature and relative humidity can be wirelessly monitored. Furthermore, we found striking differences in inactivation efficacies against some of the tested microorganisms. Overall, we conclude that dry fogging a mixture of aPAA-HP is highly effective against a broad range of microorganisms as well as material compatible with relevant concentrations. Furthermore, CSC are artificial bioindicators with lower resistance and thus should not be used for validating airborne disinfection when microorganisms other than viruses have to be inactivated. IMPORTANCE Airborne disinfection is not only of crucial importance for the safe operation of laboratories and animal rooms where infectious agents are handled but also can be used in public health emergencies such as the current severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. We show that dry fogging an aerosolized mixture of peroxyacetic acid and hydrogen peroxide (aPAA-HP) is highly microbicidal, efficient, fast, robust, environmentally neutral, and a suitable airborne disinfection method. In addition, the low concentration of dispersed disinfectant, particularly for enveloped viral pathogens such as SARS-CoV-2, entails high material compatibility. For these reasons and due to the relative simplicity of the procedure, it is an ideal disinfection method for hospital wards, ambulances, public conveyances, and indoor community areas. Thus, we conclude that this method is an excellent choice for control of the current SARS-CoV-2 pandemic.
Collapse
|
4
|
Otter J, Yezli S, Barbut F, Perl T. An overview of automated room disinfection systems: When to use them and how to choose them. DECONTAMINATION IN HOSPITALS AND HEALTHCARE 2020. [PMCID: PMC7153347 DOI: 10.1016/b978-0-08-102565-9.00015-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Conventional disinfection methods are limited by reliance on the operator to ensure appropriate selection, formulation, distribution, and contact time of the agent. Automated room disinfection (ARD) systems remove or reduce reliance on operators and so they have the potential to improve the efficacy of terminal disinfection. The most commonly used systems are hydrogen peroxide vapor (H2O2 vapor), aerosolized hydrogen peroxide (aHP), and ultraviolet (UV) light. These systems have important differences in their active agent, delivery mechanism, efficacy, process time, and ease of use. The choice of ARD system should be influenced by the intended application, the evidence base for effectiveness, practicalities of implementation, and cost considerations.
Collapse
Affiliation(s)
- J.A. Otter
- NIHR Health Protection Research Unit (HPRU) in HCAIs and AMR at Imperial College London, and Imperial College Healthcare NHS Trust, Infection Prevention and Control, London, United Kingdom
| | - S. Yezli
- Global Centre for Mass Gatherings Medicine, WHO Collaborating Centre for Mass Gatherings Medicine, Ministry of Health-Public Health Directorate, Riyadh, Kingdom of Saudi Arabia
| | - F. Barbut
- National Reference Laboratory for C. difficile, Infection Control Unit, Hôpital Saint Antoine, Paris, France,INSERM S-1139, Faculté de Pharmacie de Paris, Université de Paris, Paris, France
| | - T.M. Perl
- Infectious Diseases and Geographic Medicine, UT Southwestern Medical Center, Dallas, TX, United States
| |
Collapse
|
5
|
Pottage T, Lewis S, Lansley A, Fraser S, Hendon-Dunn C, Bacon J, Ngabo D, Parks SR, Bennett AM. Hazard Group 3 agent decontamination using hydrogen peroxide vapour in a class III microbiological safety cabinet. J Appl Microbiol 2019; 128:116-123. [PMID: 31559683 DOI: 10.1111/jam.14461] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Revised: 09/09/2019] [Accepted: 09/23/2019] [Indexed: 11/30/2022]
Abstract
AIMS This study investigated the efficacy of hydrogen peroxide vapour (HPV) at inactivating hazard group 3 bacteria that have been presented dried from their growth medium to present a realistic challenge. METHODS AND RESULTS Hydrogen peroxide vapour technology (Bioquell) was used to decontaminate a class III microbiological safety cabinet containing biological indicators (BIs) made by drying standard working suspensions of the following agents: Bacillus anthracis (Ames) spores, Brucella abortus (strain S99), Burkholderia pseudomallei (NCTC 12939), Escherichia coli O157 ST11 (NCTC 12079), Mycobacterium tuberculosis (strain H37Rv) and Yersinia pestis (strain CO92) on stainless steel coupons. Extended cycles were used to expose the agents for 90 min. The HPV cycle completely inactivated B. anthracis spores, B. abortus, B. pseudomallei, E. coli O157 and Y. pestis when BIs were processed using quantitative and qualitative methods. Whilst M. tuberculosis was not completely inactivated, it was reduced by 4 log10 from a starting concentration of 106 colony-forming units. CONCLUSIONS This study demonstrates that HPV is able to inactivate a range of HG3 agents at high concentrations with associated organic matter, but M. tuberculosis showed increased resistance to the process. SIGNIFICANCE AND IMPACT OF THE STUDY This publication demonstrates that HPV can inactivate HG3 agents that have an organic load associated with them. It also shows that M. tuberculosis has higher resistance to HPV than other agents. This shows that an appropriate BI to represent the agent of interest should be chosen to demonstrate a decontamination is successful.
Collapse
Affiliation(s)
- T Pottage
- Biosafety, Air and Water Microbiology Group, National Infection Service, Public Health England, Salisbury, UK
| | - S Lewis
- Novel and Dangerous Pathogens Training, National Infection Service, Public Health England, Salisbury, UK
| | - A Lansley
- Novel and Dangerous Pathogens Training, National Infection Service, Public Health England, Salisbury, UK
| | - S Fraser
- Novel and Dangerous Pathogens Training, National Infection Service, Public Health England, Salisbury, UK
| | - C Hendon-Dunn
- TB Research Group, National Infection Service, Public Health England, Salisbury, UK
| | - J Bacon
- TB Research Group, National Infection Service, Public Health England, Salisbury, UK
| | - D Ngabo
- Medical Interventions Group, National Infection Service, Public Health England, Salisbury, UK
| | - S R Parks
- Biosafety, Air and Water Microbiology Group, National Infection Service, Public Health England, Salisbury, UK
| | - A M Bennett
- Biosafety, Air and Water Microbiology Group, National Infection Service, Public Health England, Salisbury, UK
| |
Collapse
|
6
|
Freyssenet C, Karlen S. Plasma-Activated Aerosolized Hydrogen Peroxide (aHP) in Surface Inactivation Procedures. APPLIED BIOSAFETY 2019; 24:10-19. [PMID: 36034636 PMCID: PMC9093241 DOI: 10.1177/1535676018818559] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
INTRODUCTION Hydrogen peroxide is a strong oxidant that possesses an antimicrobial activity. It has been successfully used in surface/room decontamination processes either under the form of hydrogen peroxide vapor (HPV) or of vaporized hydrogen peroxide (VHP). Aerosolized hydrogen peroxide (aHP) offers a third alternative. The technology relies on the dispersion of aerosols of a hydrogen peroxide solution often complemented with silver cations. aHP provides an inexpensive and safe approach to treat contaminated rooms but sometimes fails to achieve the 6-log10 reduction limit in the number of viable microorganisms. METHODS Here, we used a venturi-based aHP generator that generates 4 mm in size aerosols from a 12% plasma-activated hydrogen peroxide solution free of silver cations. RESULTS & DISCUSSION We could successfully and constantly inactivate bacterial growth from biological indicators containing at least 106 spores of Geobacillus stearothermophilus placed on stainless steel discs wrapped in Tyvek pouches. We could also show that the biological indicators placed at various locations in a class II biosafety cabinet were equally inactivated, showing that hydrogen peroxide aerosols migrate through HEPA filters. CONCLUSIONS Considering that our method for aerosol generation is simple, reproducible, and highly effective at inactivating spores, our approach is expected to serve as a relatively cost effective alternative method for disinfecting potentially contaminated rooms or surfaces.
Collapse
Affiliation(s)
- Camille Freyssenet
- Swiss Federal Institute of Technology Lausanne, EPFL RHO DSPS, Lausanne, Switzerland
| | - Stéphane Karlen
- Swiss Federal Institute of Technology Lausanne, EPFL RHO DSPS, Lausanne, Switzerland
| |
Collapse
|
7
|
Operation Department: Infection Control. PREVENTION AND CONTROL OF INFECTIONS IN HOSPITALS 2019. [PMCID: PMC7122724 DOI: 10.1007/978-3-319-99921-0_35] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Infection control in the operation department is the result of many single factors and routines, based on experience, documentation and expert panels through more than a hundred years. Many factors and routines in surgery are evidence-based, but most of them are still lacking evidence and can probably never be investigated because of ethical problems. Consequently, consensus and guidance are used to a great extent. Surgery opens into sterile tissues for hours, where there is massive tissue damage by knife, diathermy, clogging of vessels, pressure against and drying of tissues, decreased blood supply, impaired phagocytosis and impaired infection defence. Microbes deposited in this devitalized tissues may find a good basis for growth and proliferation if there is lack of infection control and sterility. For patients with ongoing infections and who need surgery, special routines are made to prevent the spread of infections in the operation department. This chapter is a practical description of many important preventive procedures that may protect the surgical patient against surgical site infection (SSI).
Collapse
|
8
|
Andersen BM. Background Information: Isolation Routines. PREVENTION AND CONTROL OF INFECTIONS IN HOSPITALS 2019. [PMCID: PMC7122118 DOI: 10.1007/978-3-319-99921-0_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The isolation of patients with suspected or documented infections—to not spread to others—has been discussed for hundreds of years. Guidelines are many, methods are different, attitudes show vide variations, routines and procedures are still changing, regulations by law may be absent, and some healthcare professionals may be afraid of adverse outcomes of isolation [1–44]. Microbes that are spread in the environment, on the hands and equipment are invisible. The invisible agent does not call on attention before the infection; clinical disease, hospital infection or nosocomial infection is a factum that can be registered [23, 28, 29, 35–37]. How to stop the transmission is often “to believe and not believe” in infection control.
Collapse
|
9
|
Development of antituberculosis melt-blown polypropylene filters coated with mangosteen extracts for medical face mask applications. Polym Bull (Berl) 2018. [DOI: 10.1007/s00289-018-2468-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
10
|
Malik DJ, Shaw CM, Shama G, Clokie MRJ, Rielly CD. An Investigation into the Inactivation Kinetics of Hydrogen Peroxide Vapor Against Clostridium difficile Endospores. CHEM ENG COMMUN 2016. [DOI: 10.1080/00986445.2016.1223058] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- D. J. Malik
- Department of Chemical Engineering, Loughborough University, Loughborough, Leicester, LE11 3TU, UK
| | - C. M. Shaw
- Department of Chemical Engineering, Loughborough University, Loughborough, Leicester, LE11 3TU, UK
| | - G. Shama
- Department of Chemical Engineering, Loughborough University, Loughborough, Leicester, LE11 3TU, UK
| | - M. R. J. Clokie
- Department of Infection, Immunity and Inflammation, University of Leicester, Leicester, LE1 9HN, UK
| | - C. D. Rielly
- Department of Chemical Engineering, Loughborough University, Loughborough, Leicester, LE11 3TU, UK
| |
Collapse
|
11
|
Murdoch LE, Bailey L, Banham E, Watson F, Adams NMT, Chewins J. Evaluating different concentrations of hydrogen peroxide in an automated room disinfection system. Lett Appl Microbiol 2016; 63:178-82. [PMID: 27324207 DOI: 10.1111/lam.12607] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2016] [Revised: 05/23/2016] [Accepted: 06/14/2016] [Indexed: 12/01/2022]
Abstract
UNLABELLED A comparative study was made on the efficacy of 5, 10 and 35% weight by weight (w/w) hydrogen peroxide solutions when applied using an automated room disinfection system. Six-log biological indicators of methicillin-resistant Staphylococcus aureus (MRSA) and Geobacillus stearothermophilus were produced on stainless steel coupons and placed within a large, sealed, environmentally controlled enclosure. Five percent hydrogen peroxide was distributed throughout the enclosure using a Bioquell hydrogen peroxide vapour generator (BQ-50) for 40 min and left to reside for a further 200 min. Biological indicators were removed at 10-min intervals throughout the first 120 min of the process. The experiment was repeated for 10 and 35% hydrogen peroxide solutions. Five percent and 10% hydrogen peroxide solutions failed to achieve any reduction of MRSA, but achieved full kill of G. stearothermophilus spores at 70 and 40 min respectively. Thirty-five percent hydrogen peroxide achieved a 6-log reduction of MRSA after 30 min and full kill of G. stearothermophilus at 20 min. The concentration of 5% hydrogen peroxide within the enclosure after the 200-min dwell was measured at 9·0 ppm. This level exceeds the 15-min Short Term Exposure Limit (STEL) for hydrogen peroxide of 2·0 ppm. Users of automated hydrogen peroxide disinfection systems should review system efficacy and room re-entry protocols in light of these results. SIGNIFICANCE AND IMPACT OF THE STUDY This research allows hospital infection control teams to consider the impact and risks of using low concentrations of hydrogen peroxide for disinfection within their facilities, and to question automated room disinfection system providers on the efficacy claims they make. The evidence that low concentration hydrogen peroxide solutions do not rapidly, autonomously break down, is in contradiction to the claims made by some hydrogen peroxide equipment providers and raises serious health and safety concerns. Facilities using hydrogen peroxide systems that claim autonomous break down of hydrogen peroxide should introduce monitoring procedures to ensure rooms are safe for re-entry and patient occupation.
Collapse
Affiliation(s)
- L E Murdoch
- Wickham Laboratories, Gosport, Hampshire, UK
| | - L Bailey
- Wickham Laboratories, Gosport, Hampshire, UK
| | - E Banham
- Wickham Laboratories, Gosport, Hampshire, UK
| | - F Watson
- Wickham Laboratories, Gosport, Hampshire, UK
| | - N M T Adams
- Wickham Laboratories, Gosport, Hampshire, UK
| | - J Chewins
- Wickham Laboratories, Gosport, Hampshire, UK
| |
Collapse
|
12
|
Weber DJ, Rutala WA, Anderson DJ, Chen LF, Sickbert-Bennett EE, Boyce JM. Effectiveness of ultraviolet devices and hydrogen peroxide systems for terminal room decontamination: Focus on clinical trials. Am J Infect Control 2016; 44:e77-84. [PMID: 27131140 PMCID: PMC7132689 DOI: 10.1016/j.ajic.2015.11.015] [Citation(s) in RCA: 95] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2015] [Accepted: 11/10/2015] [Indexed: 02/08/2023]
Abstract
Over the last decade, substantial scientific evidence has accumulated that indicates contamination of environmental surfaces in hospital rooms plays an important role in the transmission of key health care-associated pathogens (eg, methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, Clostridium difficile, Acinetobacter spp). For example, a patient admitted to a room previously occupied by a patient colonized or infected with one of these pathogens has a higher risk for acquiring one of these pathogens than a patient admitted to a room whose previous occupant was not colonized or infected. This risk is not surprising because multiple studies have demonstrated that surfaces in hospital rooms are poorly cleaned during terminal cleaning. To reduce surface contamination after terminal cleaning, no touch methods of room disinfection have been developed. This article will review the no touch methods, ultraviolet light devices, and hydrogen peroxide systems, with a focus on clinical trials which have used patient colonization or infection as an outcome. Multiple studies have demonstrated that ultraviolet light devices and hydrogen peroxide systems have been shown to inactivate microbes experimentally plated on carrier materials and placed in hospital rooms and to decontaminate surfaces in hospital rooms naturally contaminated with multidrug-resistant pathogens. A growing number of clinical studies have demonstrated that ultraviolet devices and hydrogen peroxide systems when used for terminal disinfection can reduce colonization or health care-associated infections in patients admitted to these hospital rooms.
Collapse
Affiliation(s)
- David J Weber
- Department of Hospital Epidemiology, University of North Carolina Health Care, Chapel Hill, NC; Division of Infectious Diseases, University of North Carolina School of Medicine, Chapel Hill, NC.
| | - William A Rutala
- Department of Hospital Epidemiology, University of North Carolina Health Care, Chapel Hill, NC; Division of Infectious Diseases, University of North Carolina School of Medicine, Chapel Hill, NC
| | | | - Luke F Chen
- Division of Infectious Diseases, Duke University Medical School, Durham, NC
| | - Emily E Sickbert-Bennett
- Department of Hospital Epidemiology, University of North Carolina Health Care, Chapel Hill, NC; Division of Infectious Diseases, University of North Carolina School of Medicine, Chapel Hill, NC
| | - John M Boyce
- Division of Infectious Diseases, Yale School of Medicine, New Haven, CT
| |
Collapse
|
13
|
Pyrgiotakis G, Vedantam P, Cirenza C, McDevitt J, Eleftheriadou M, Leonard SS, Demokritou P. Optimization of a nanotechnology based antimicrobial platform for food safety applications using Engineered Water Nanostructures (EWNS). Sci Rep 2016; 6:21073. [PMID: 26875817 PMCID: PMC4753486 DOI: 10.1038/srep21073] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2015] [Accepted: 01/08/2016] [Indexed: 11/09/2022] Open
Abstract
A chemical free, nanotechnology-based, antimicrobial platform using Engineered Water Nanostructures (EWNS) was recently developed. EWNS have high surface charge, are loaded with reactive oxygen species (ROS), and can interact-with, and inactivate an array of microorganisms, including foodborne pathogens. Here, it was demonstrated that their properties during synthesis can be fine tuned and optimized to further enhance their antimicrobial potential. A lab based EWNS platform was developed to enable fine-tuning of EWNS properties by modifying synthesis parameters. Characterization of EWNS properties (charge, size and ROS content) was performed using state-of-the art analytical methods. Further their microbial inactivation potential was evaluated with food related microorganisms such as Escherichia coli, Salmonella enterica, Listeria innocua, Mycobacterium parafortuitum, and Saccharomyces cerevisiae inoculated onto the surface of organic grape tomatoes. The results presented here indicate that EWNS properties can be fine-tuned during synthesis resulting in a multifold increase of the inactivation efficacy. More specifically, the surface charge quadrupled and the ROS content increased. Microbial removal rates were microorganism dependent and ranged between 1.0 to 3.8 logs after 45 mins of exposure to an EWNS aerosol dose of 40,000 #/cm(3).
Collapse
Affiliation(s)
- Georgios Pyrgiotakis
- Center for Nanotechnology and Nanotoxicology, Harvard School of Public Health, Harvard University, Boston, MA, USA
| | - Pallavi Vedantam
- Center for Nanotechnology and Nanotoxicology, Harvard School of Public Health, Harvard University, Boston, MA, USA
| | - Caroline Cirenza
- Center for Nanotechnology and Nanotoxicology, Harvard School of Public Health, Harvard University, Boston, MA, USA
| | - James McDevitt
- Center for Nanotechnology and Nanotoxicology, Harvard School of Public Health, Harvard University, Boston, MA, USA
| | | | | | - Philip Demokritou
- Center for Nanotechnology and Nanotoxicology, Harvard School of Public Health, Harvard University, Boston, MA, USA
| |
Collapse
|
14
|
Holmdahl T, Lanbeck P, Wullt M, Walder MH. A Head-to-Head Comparison of Hydrogen Peroxide Vapor and Aerosol Room Decontamination Systems. Infect Control Hosp Epidemiol 2015; 32:831-6. [DOI: 10.1086/661104] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Objective.New technologies have emerged in recent years for the disinfection of hospital rooms and equipment that may not be disinfected adequately using conventional methods. There are several hydrogen peroxide–based area decontamination technologies on the market, but no head-to-head studies have been performed.Design.We conducted a head-to-head in vitro comparison of a hydrogen peroxide vapor (HPV) system (Bioquell) and an aerosolized hydrogen peroxide (aHP) system (Sterinis).Setting.The tests were conducted in a purpose-built 136-m3test room.Methods.One HPV generator and 2 aHP machines were used, following recommendations of the manufacturers. Three repeated tests were performed for each system. The microbiological efficacy of the 2 systems was tested using 6-log Tyvek-pouchedGeobacillus stearo-thermophilusbiological indicators (BIs). The indicators were placed at 20 locations in the first test and 14 locations in the subsequent 2 tests for each system.Results.All BIs were inactivated for the 3 HPV tests, compared with only 10% in the first aHP test and 79% in the other 2 aHP tests. The peak hydrogen peroxide concentration was 338 ppm for HPV and 160 ppm for aHP. The total cycle time (including aeration) was 3 and 3.5 hours for the 3 HPV tests and the 3 aHP tests, respectively. Monitoring around the perimeter of the enclosure with a handheld sensor during tests of both systems did not identify leakage.Conclusion.One HPV generator was more effective than 2 aHP machines for the inactivation ofG. stearothermophilusBIs, and cycle times were faster for the HPV system.
Collapse
|
15
|
Quoi de neuf dans les techniques de désinfection des chambres de réanimation ? MEDECINE INTENSIVE REANIMATION 2014. [DOI: 10.1007/s13546-014-0884-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
16
|
Mycobacteria inactivation using Engineered Water Nanostructures (EWNS). NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2014; 10:1175-83. [PMID: 24632246 DOI: 10.1016/j.nano.2014.02.016] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Revised: 02/21/2014] [Accepted: 02/28/2014] [Indexed: 11/20/2022]
Abstract
UNLABELLED Airborne transmitted pathogens such as Mycobacterium tuberculosis (Mtb) cause serious, often fatal infectious disease with enormous global health implications. Due to their unique cell wall and slow growth, mycobacteria are among the most resilient microbial forms. Herein we evaluate the ability of an emerging, chemical-free, nanotechnology-based method to inactivate M. parafortuitum (Mtb surrogate). This method is based on the transformation of atmospheric water vapor into engineered water nano-structures (EWNS) via electrospray. We demonstrate that the EWNS can interact with and inactivate airborne mycobacteria, reducing their concentration levels significantly. Additionally, EWNS can inactivate M. parafortuitum on surfaces eight times faster than the control. The mechanism of mycobacteria inactivation was also investigated in this study. It was demonstrated that the EWNS effectively deliver the reactive oxygen species, encapsulated during the electrospray process, to the bacteria oxidizing their cell membrane resulting into inactivation. Overall, this is a method with the potential to become an effective intervention technology in the battle against airborne infections. FROM THE CLINICAL EDITOR This study demonstrates the feasibility of mycobacterium inactivation in airborne form or on contact surfaces using electrospray activated water nano-structures. Given that the method is free of toxic chemicals, this might become an important tool in the prevention of mycobacterial infections, which are notoriously hard to treat.
Collapse
|
17
|
Abstract
Conventional disinfection methods are limited by reliance on the operator to ensure appropriate selection, formulation, distribution and contact time of the agent. ‘No-touch’ automated room disinfection (NTD) systems remove or reduce reliance on operators and so they have the potential to improve the efficacy of terminal disinfection. The most commonly used systems are hydrogen peroxide vapour (H2O2 vapour), aerosolised hydrogen peroxide (aHP) and ultraviolet (UV) radiation. These systems have important differences in their active agent, delivery mechanism, efficacy, process time and ease of use. The choice of NTD system should be influenced by the intended application, the evidence base for effectiveness, practicalities of implementation and cost constraints.
Collapse
|
18
|
Otter JA, Yezli S, Perl TM, Barbut F, French GL. The role of 'no-touch' automated room disinfection systems in infection prevention and control. J Hosp Infect 2012. [PMID: 23195691 DOI: 10.1016/j.jhin.2012.10.002] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Surface contamination in hospitals is involved in the transmission of pathogens in a proportion of healthcare-associated infections. Admission to a room previously occupied by a patient colonized or infected with certain nosocomial pathogens increases the risk of acquisition by subsequent occupants; thus, there is a need to improve terminal disinfection of these patient rooms. Conventional disinfection methods may be limited by reliance on the operator to ensure appropriate selection, formulation, distribution and contact time of the agent. These problems can be reduced by the use of 'no-touch' automated room disinfection (NTD) systems. AIM To summarize published data related to NTD systems. METHODS Pubmed searches for relevant articles. FINDINGS A number of NTD systems have emerged, which remove or reduce reliance on the operator to ensure distribution, contact time and process repeatability, and aim to improve the level of disinfection and thus mitigate the increased risk from the prior room occupant. Available NTD systems include hydrogen peroxide (H(2)O(2)) vapour systems, aerosolized hydrogen peroxide (aHP) and ultraviolet radiation. These systems have important differences in their active agent, delivery mechanism, efficacy, process time and ease of use. Typically, there is a trade-off between time and effectiveness among NTD systems. The choice of NTD system should be influenced by the intended application, the evidence base for effectiveness, practicalities of implementation and cost constraints. CONCLUSION NTD systems are gaining acceptance as a useful tool for infection prevention and control.
Collapse
Affiliation(s)
- J A Otter
- Centre for Clinical Infection and Diagnostics Research, CIDR, Department of Infectious Diseases, King's College London, School of Medicine and Guy's and St Thomas' NHS Foundation Trust, UK.
| | | | | | | | | |
Collapse
|
19
|
Gordon D, Carruthers BA, Theriault S. Gaseous Decontamination Methods in High-containment Laboratories. APPLIED BIOSAFETY 2012. [DOI: 10.1177/153567601201700107] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Diane Gordon
- Public Health Agency of Canada, Winnipeg, Manitoba, Canada
| | | | | |
Collapse
|
20
|
Otter J, Yezli S. Are commercially available Geobacillus stearothermophilus biological indicators an appropriate standard for hydrogen peroxide vapour systems in hospitals? J Hosp Infect 2012; 80:272-3. [DOI: 10.1016/j.jhin.2011.12.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2011] [Accepted: 12/22/2011] [Indexed: 11/25/2022]
|
21
|
Activity of a dry mist-generated hydrogen peroxide disinfection system against methicillin-resistant Staphylococcus aureus and Acinetobacter baumannii. Am J Infect Control 2011; 39:757-62. [PMID: 21531042 DOI: 10.1016/j.ajic.2010.12.003] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2010] [Revised: 11/30/2010] [Accepted: 12/01/2010] [Indexed: 11/20/2022]
Abstract
BACKGROUND The aim of this study was to evaluate the activity of a dry mist-generated hydrogen peroxide (DMHP) system (Sterinis; Gloster Sante Europe, Labege cedex, France) against methicillin-resistant Staphylococcus aureus (MRSA) and Acinetobacter baumannii. METHODS McFarland 0.5 suspensions of 2 test bacteria, either pure or containing 5% sterile serum, were prepared and inoculated onto sterile stainless steel disks. Each disk in a Petri dish-with the Petri dish cover either closed or open-was placed in different locations in an intensive care unit room. Quantitative cultures were performed after the cycle. RESULTS No growth occurred on the disks in the absence of a barrier, except 1 disk containing serum. Existence of a barrier, as a drawer or a covered Petri dish, caused failure in the disinfection activity. The mean reduction in initial log(10) bacterial count was lower for both of the test bacteria in presence of a barrier: 4.44- to 4.70-log(10) colony-forming units (cfu) decrease was observed in absence of a barrier, whereas 1.49- to 3.79-log(10) cfu decrease was observed in presence of a barrier. When the culture results were compared according to organic load content, the mean (±standard deviation) reduction of initial contamination in pure and in serum containing MRSA suspensions was 4.25 ± 1.20- and 3.34 ± 1.89-log(10) cfu, respectively. The mean (±standard deviation) reduction in pure and in serum containing A baumannii suspensions was 4.34 ± 0.89- and 3.87 ± 1.26-log(10) cfu, respectively. The differences were statistically significant (P < .001). CONCLUSION Sterinis was capable of killing MRSA and A baumannii on open surfaces; however, it was not effective in closed or semiclosed areas. Presence of serum also caused failure in the disinfection activity of the system.
Collapse
|